Chiller/Heat pumps 30AWH. Reversible. Monobloc inverter



Similar documents
Cooling kw Heating kw

LG Electronics AE Company, Commercial Air Conditioning

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

ROTEX gas hybrid heat pump. A strong team.

york air-conditioning products Residential & VRF News 2015

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

Natural geothermal energy.

Versati Air to Water Heat Pump

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

The natural ombination

Hybrid heat pumps. saving energy and reducing carbon emissions

ECOCIAT. Domestic hot water heat recovery unit

FULL DC INVERTER SYSTEMS

The natural ombination

Electric Flow Boiler

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

HP switch LP switch Discharge thermo Comp. Surface thermo

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Daikin Altherma Hybrid Heat Pump

DAikin Altherma low temperature heat pump. end user leaflet

ZUBA-CENTRALTM. Heating & Cooling. Evolved. HEATING AND AIR CONDITIONING FOR WHOLE-HOME, YEAR-ROUND COMFORT

ELECTRIC CENTRAL HEATING FLOW BOILER

Daikin Altherma hybrid heat pump. The natural combination

Daikin Altherma Hybrid Heat Pump

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

News in Data Center Cooling

Vitocaldens 222-F Compact Gas-Hybrid appliance

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary

A Class Air Source Heat Pump User Guide

AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS

Create the right atmosphere with renewables.

Smile. The All-In-One Heating Controller

CRAC Precision climate control units for data centres

AIR-CONDITIONER SPLIT TYPE

Daikin Altherma. hybrid heat pump. The natural combination

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE

Inverter Air Conditioning for Light Commercial Use

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

DUCTED AIR CONDITIONING SOLUTIONS

Inverter technology. bulletin

SWIMMING POOL HEAT PUMP Owners Manual

Contents. Part 1 General Information Part 2 Outdoor Units Part 3 Installation Part 4 Troubleshooting 73

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

The heat is there let s use it! Using free environmental heat from the air with heat pump technology for central heating and domestic hot water

Fan Coil Units. Fan coil units with brushless DC motor with inverter. your comfort. our world. » Up to 70% energy saving with BLDC motor technology

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

Nordic Heat Pump Product Guide

Small-Scale Solar Heating and Cooling Systems

YUTAKI S. Domestic Heating

The Benefits Really Add Up

HEATING, VENTILATION & AIR CONDITIONING

GUIDE TO AIR SOURCE HEAT PUMPS. Consumer, Specifier, Installer and Merchant guide to Air to water heat pump technology

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump

AIR SOURCE CHILLERS FOR OUTDOOR INSTALLATION

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

KONRAD. Hybrid Fancoil Series

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Crowne Plaza Copenhagen Towers The world s greenest hotel

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

USER S MANUAL HSC-24A

elcome to the era of the SEER seasonal efficiency Product range

HEATER, AIR CONDITIONING AND VENTILATION

HERZ-Thermal Actuators

DIABLO VALLEY COLLEGE CATALOG

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction

Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: Fax:

GREE, MAKING BETTER AIR CONDITIONERS

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

We have been working in an ideal climate for thirty years.

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

CoolTeg Plus Chilled Water (CW) version: AC-TCW

HVAC Systems: Overview

SECTION HEAT PUMPS

Unico Inverter. Unique and efficient.

AQUACIAT2 HYBRID THE COMPACT DUAL-ENERGY SOLUTION HEAT PUMP & GAS BOILER. Cooling and heating capacities of 45 to 80 kw AVAILABLE 2 ND QUARTER OF 2014

Commercial Hot Water. Make a difference...

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Intelligent control system with integrated electronic expansion valves in an air-conditioning system operating at a Telecom telephone exchange

Air conditioners Heating & Cooling

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

SEERS International. Hybrid Hot Water Systems. Innovation Technology

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

PANASONIC TROUBLE SHOOTING GUIDE

Air-cooled Chillers with High Speed Centrifugal Compressors

IV. Rear Mount System

Transcription:

Chiller/Heat pumps 30AWH Reversible Monobloc inverter C O M P A C T, R E L I A B L E A N D E F F I C I E N T

Reversible Compact, reliable and efficient 2 The new AquaSnap PLUS chillers and reversible heat pumps were designed and tested to address the specifc needs of residential and light commercial buildings. Residential homes Mid-size apartments Shops and laboratories Carrier engineers were able to incorporate reliable quality components in its compact chassis including one of the most advanced electronic inverter controls in the industry. The 30AW boasts impressive energy efficiency and can be easily matched with the wide range of Carrier terminal fan coil units. Doctor s surgeries Family hotels Offices and waiting rooms DC Inverter Power at peak load conditions combined with efficiency for standard operation Patented fan design Innovative blade profle to maximise the supply air flow

More than an heat pump AquaSnap PLUS heat pumps offer the ideal solution for a wide range of applications in a new building, a refurbishment project or integrated with existing equipment. Carrier experts always provide the right system. Dual energy applications The reversible AquaSnap PLUS heat pump can be integrated with existing heat sources. Simply define the parameters for switching to an alternative heat source and enjoy continuous operation with increased savings and optimum comfort in all weather conditions. 3 COLD/HOT WATER PRODUCTION Heat pump / chiller INTEGRATION Hydronic module Boiler Dehumidiifier DISTRIBUTION Under-floor systems Radiators Fan coils CUSTOMISATION Solar panels Swimming pool heater Domestic hot water production Advanced technology Brazed plate heat exchanger Pulse modulating valve High efficiency, with anti-corrosion protection Electronically optimises the refrigerant flow in the circuit DC Fan motor GMC Controller Brushless, vibrationfree DC motor for increased fan performance and reliability Co Continuously analyses water, ambient conditions w and customer inputs to an provide the correct pr operating parameters op Twin rotary compressor Two-rotary compression cylinders, offset by 180 and a brushless DC motor with a perfectly balanced shaft

4 COP>3,90 EER>3,60 ESEER>4,30 Carrier DC inverters deliver improved reliability and optimised energy-efficiency from 20 up to 120% of nominal capacity. Carrier s exclusive hybrid DC inverter technology, used in the AquaSnap PLUS heat pump, combines two distinct electronic management logics (PAM and PWM) to optimise compressor operation in all operating conditions. Pulse Amplitude Modulation (PAM) of the direct current drives the compressor at maximum load conditions (start-up and peak load conditions), increasing voltage at fixed frequency. The compressor works at high speed to rapidly achieve the desired temperature. Pulse Width Modulation (PWM) of the direct current drives the compressor at part load conditions, adjusting frequency at fixed voltage. The compressor speed is fine-tuned and the system provides high-level comfort without temperature fluctuations. The AquaSnap PLUS reversible heat pump and chiller offers an exceptionally high energy efficiency ratio both in cooling (EER) and heating (COP). This translates into substantial savings for the user. With their low energy consumption the 30AW units can also qualify for local tax reductions and incentive programmes in all EU countries. The seasonal efficiency (at part load) of the AquaSnap PLUS reversible heat pump is one of the highest in the industry. C.O.P. Rating point Rating point Energy-efficiency class A for size 06 in underfloor heating applications. PAM PWM Maximum power at high speed and unmatched efficiency at low and medium speed. Compressor Frequency (%) Seasonal energy efficiency The inverter efficiency ratio is calculated at nominal value, when the compressors run at 100% capacity. But in practice the unit operates at lower compressor speeds (part load) 75% of the time. Here the Carrier inverter technology has one of the highest efficiency ratios. GMC controller The platform has been enhanced with a new, sophisticated algorithm for use with the new inverter board. The extended features include: customised or pre-de ned climate curves domestic hot water control night noise reduction function defrost/alarm output signal external heat source pump blockage protection function freeze protection compressor operation management C_10_BR_HP_30AW_EN 1-8_49.indd 4 29/10/2010 11.30.37

Comfort Hybrid DC inverter technology modulates the compressor speed to match the load to give stable and controlled temperatures without fluctuations. Heating on cold days with outside temperature down to -20 C. Energy-efficient cooling during the summer. Low sound levels In addition to the use of the twin-rotary compressor, particular attention was given to noise elimination or reduction in all the moving parts. This led to a new propeller fan shape, dual insulation for the compressor and a new damper for the vibrating components. 5 Domestic hot water The leaving water temperature of up to 60 C is ideal for hot water for domestic use. User interfaces 33AW-CSI Programmable thermostat The new ComfortTM series user interface has a large display to show all system settings and operating parameters plus extended features like schedule timer, silent mode and pre-set operating programs. Auto-diagnosis and automatic configuration programs guide the technicians during commissioning and servicing. Touch N Go This unique feature on the remote control is a revolutionary simple programming option - literally, touch and go to immediately get the desired comfort settings from the system (Home, Away, Sleep). 33AW-RCI Remote controller User-friendly remote controller to manage the main unit functions: cooling, heating and Eco mode. Small and unobtrusive LEDs indicate the unit status. LEDs are also used to signal possible faults during the autodiagnosis tests.

Installation made easy Hydronic module 6 only 326 mm The 30AW version with hydronic kit (pump, expansion vessel, automatic purge valve and water pressure relief valve) increases the flexibility and ease of installation. Handles For easy transportation 3 wires Fast electrical connections Easy access to all internal componentssimply remove three screws to open the front panel and gain access to all main components for regular checks and maintenance of refrigerant pipes, control box, electrical connections, compressor hydronic kit and other key internal components. Water and drain connections are easily accessible from the rear of the unit Servicing and commissioning are facilitated by routines available on the user interface. Dealer Service Tool for remote monitoring and parameter setting via a PC. Minimum operating weight Reduced footprint Compatible with all Carrier fan coil units 42GW Cassette

Safety and performances certified by independent organisations The United Technology ACE system guarantees the highest manufacturing standards. Every unit undergoes a set of multiple tests at different stages on the production line for circuit leakage, electrical conformity, correct water and refrigerant pressure. The use of high-quality parts and components guarantees the overall quality and reliability of the 30AW AquaSnap PLUS unit. The hybrid DC compressor with its twin-rotary cylinders reduces the stress on the parts, and therefore increases unit operating life. The AquaSnap PLUS heat pumps use air as a primary energy source. This results in reduced use of natural resources and redused CO² emissions to the atmosphere. All unit components are free of any hazardous substances and specifically designed to operate effectively with chlorine-free refrigerant R-410A, which has an Ozone Depleting Potential (ODP) of zero. Recyclable packaging Carrier is committed to reduce the amount of polluting material and this is reflected in the design of the unit packaging. The material used to protect the unit during its transport is 100% recyclable. 42N Floor and under-ceiling 42DW / 42EM False ceiling 42BJ / 42GR Suspended ceiling 7

P h y s i c a l D a t a 30AWH 004 006 008 012 015 12-3Ph 15-3Ph Data at Eurovent LCP /A/CHF conditions* Nominal heating capacity kw 4.1 5.8 7.2 11.9 14.5 12.0 15.0 Power input kw 0.98 1.35 1.80 3.01 3.54 2.79 3.57 COP kw/kw 4.15 4.28 3.97 3.95 4.09 4.30 4.20 Eurovent class, heating A A B B A A A Nominal cooling capacity kw 4.9 7.0 7.8 13.5 16.0 13.5 16.0 Power input kw 1.17 1.90 1.96 3.70 4.17 3.25 4.20 EER kw/kw 4.20 3.70 3.99 3.66 3.85 4.15 3.81 Eurovent class, cooling A B A B A A A Data at Eurovent LCP /A/AC conditions** Nominal heating capacity kw 3.9 5.8 7.4 12.9 14.0 11.2 14.5 Power input kw 1.19 1.89 2.31 4.26 4.32 3.34 4.39 COP kw/kw 3.26 3.05 3.19 3.03 3.23 3.35 3.30 Eurovent class, heating A B B B A A A Nominal cooling capacity kw 3.3 4.7 5.8 10.2 13.0 10.2 13.0 Power input kw 1.10 1.58 1.96 3.46 4.42 3.40 4.47 EER kw/kw 3.02 3.00 2.98 2.96 2.95 3.00 2.91 ESEER part-load performance kw/kw 4.4 4.5 4.2 4.2 4.3 4.4 4.3 Eurovent class, cooling B B B B B B B Nominal heating capacity, radiator applications*** kw 4.1 5.4 6.5 11.5 11.7 5.0 12.0 Power input kw 1.48 2.07 2.68 4.60 4.13 3.96 4.21 COP kw/kw 2.75 2.60 2.41 2.49 2.82 2.80 2.85 Operating weight kg Unit without hydronic module 54 58 66 101 109 113 113 Unit with hydronic module 57 61 69 104 112 116 116 Refrigerant R410-A Compressor DC twin-rotary Expansion valve PMV Fans Propeller fans Quantity/diameter mm 1/495 1/495 1/495 2/495 2/495 2/495 2/495 The manufacturer reserves the right to change the product specifications, data and images without notice. *Weight shown is a guidance only. To find out the unit refrigerant charge, please refer to the unit nameplate. The water heat exchanger fouling factor is 0 (m2 K)/W for all conditions. * Standard Eurovent LCP/A/CHF conditions in heating mode: water heat exchanger entering/leaving water temperature 30 C/35 C, outside air temperature 7 C db/6 C wb. Standard Eurovent LCP/A/CHF conditions in cooling mode: water heat exchanger entering/leaving water temperature 23 C/18 C, outside air temperature 35 C. ** Standard Eurovent LCP/A/AC conditions in heating mode: water heat exchanger entering/leaving water temperature 40 C/45 C, outside air temperature 7 C db/6 C wb. Standard Eurovent LCP/A/AC conditions in cooling mode: water heat exchanger entering/leaving water temperature 12 C/7 C, outside air temperature 35 C. *** Conditions in heating mode: entering/leaving water temperature 55 C/a, outside air temperature 7 C db/6 C wb. Performances are in accordance with EN 14511. **** Based on the following conditions: entering/leaving water temperature 35 C/30 C, outside air temperature 7 C. Based on the following conditions: entering/leaving water temperature 12 C/7 C, outside air temperature 35 C. Electrical Data 30AWH 004 006 008 012 015 12-3Ph 15-3Ph Power supply V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 400-1-50 400-1-50 Voltage range V 198-264 198-264 198-264 198-264 198-264 376-424 376-424 Full load current A 7.2 11 14 23 20 16 16 Fuse rating A 10 16 16 25 25 20 20 Main power cable section mm 2 2.5 2.5 2.5 2.5 2.5 2.5 2.5 AHI CARRIER SOUTH EASTERN EUROPE S.A. Headquarters 18, Kifissou Ave 104 42 - Athens GREECE Tel. : +30 210 6796300 Thessaloniki Branch Ag. Georgiou 5, Cosmos Offices 570 01 - Patriarchiko Pileas, Thessaloniki GREECE Τηλ. : +30 23130 80430 Bulgaria Branch 25 Petar Dertliev blvd 1324 Sofia BULGARIA Tel : +35 929 483960 Romania Branch 270d Turnu Magurele str Sector 4 Cavar center - Bucharest ROMANIA Tel. : +40 214 050751 www.ahi-carrier.gr