Modeling, GIS Software Optimizes Water Main Cleaning By Paul F. Boulos



Similar documents
Birmingham Water Work s EnviroLab Water Quality Operations Division

Using Risk-Based GIS Modeling Software to Optimize Sewer Renewal Planning

Repair and Disinfection of Water Mains Water Protection Program fact sheet

Water Quality Contingency Planning Standard EPB 540B

INNOVATION AND COST EFFECTIVE APPROACH TO POTABLE WATER PIPE REPLACEMENT STRATEGICALLY FOCUSED ON DISTRIBUTION SYSTEM WATER QUALITY IMPROVEMENT By

Advanced_O&M_Task_List_Example_Tool_06_02_16: O&M Example

Real-time Monitoring Platform to Improve the Drinking Water Network Efficiency

Rehabilitate or Replace 10 Years of the Trenton Water Works Experience

December 2003 EPB 241B. Some sections are completed, some are partially complete and some are left blank.

The Redwood City Public Works Services (PWS) Department is comprised of four operating divisions:

RENEW. A Water Main Cleaning and Lining Program Designed to Improve Water Quality and Service

How To Improve Gis Data Quality

Emergency/Disaster Response Plan

COMPREHENSIVE DRINKING WATER SOURCE-TO-TAP ASSESSMENT GUIDELINE

WATER LEAKAGE AND DETECTION IN MUNICIPAL WATER DISTRIBUTION NETWORKS. N. Merzi (1) and T. Özkan (2)

Design Criteria & Service Goals

Optimization of Cleaning-In- Place (CIP) processes in bottled water industry

PREDICTIVE AND OPERATIONAL ANALYTICS, WHAT IS IT REALLY ALL ABOUT?

GUIDANCE FOR WATER UTILITY RESPONSE, RECOVERY & REMEDIATION ACTIONS FOR MAN-MADE AND/OR TECHNOLOGICAL EMERGENCIES

LEAK DETECTION IN UNDERGROUND PIPELINES OF MUNICIPAL WATER DISTRIBUTION

ATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING

Source Water Protection Practices Bulletin Managing Sanitary Sewer Overflows and Combined Sewer Overflows to Prevent Contamination of Drinking Water

What is water main cleaning & lining

Emerging Technologies in Wastewater Collection Systems

Enhancing Asset Management with a GIS Program. Lori A. Burkert, P.G. lburkert@entecheng.com

Bacteria Control Troubleshooting Guide for Automated Watering Systems

Affordable Asset Management Workshop Making Use of the Data You Have An Owners Perspective

Causes of Bacteria in Water Samples 1

MAINTENANCE OF SMALL WATER SUPPLY, SANITATION AND IRRIGATION SCHEMES

How To Contact The Department Of Water And Sewer Of Departmentford Mua

ACTIVITY & LOCATION BASED ANALYTICS APPLICATIONS

Remote Pressure Monitoring System* Reduce water main breaks and customer complaints

Standard Operating Guideline Maintenance Management System

SEWER CLEANING, INSPECTION AND ASSESSMENT

Implementing an Enterprise Asset Management System and Mobile Solution

PLBG/GAS SAFETY Information Bulletin

Iron and Manganese BACTERIA AND IRON AND MANGANESE

Water Loss Auditing and Water Leak Detection: How Much is Being Lost and Where Does it Go? PNWS-AWWA Annual Conference Michael W. Grimm, P.E.

Sanitary Sewer Overflow Response Plan Working Committee SANITARY SEWER OVERFLOW RESPONSE PLAN

2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS

Waste Collection Systems

Residual Chlorine Decay Simulation in Water Distribution System

Guidance Note on Flushing

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

The City of Atlanta: Investing in a Useable Water Utility GIS

Routine Maintenance and Inspection

COOLING WATER MANAGEMENT

A Solution to MOP/MAOP Data Management in PODS

Reduce Leaks Using water audits and leak detection surveys

Presented By: Fred J. Sánchez Water Quality Operations Supervisor

Indiana Department of Environmental Management. Well Disinfection

SECTION 810 SEWER LINE CLEANING

Inspection of Water Storage Facilities

SECTION DISINFECTION OF PIPE AND WATER STORAGE FACILITIES

STANDARD SPECIFICATIONS SECTION CLEANING AND LINING WATER MAINS

Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service

Recent outbreaks of pinhole leaks nationally are a significant issue. Figure 1.1 shows the

REHABILITATION METHOD FOR INCREASING FLOW VELOCITY AND REDUCING SEDIMENTATION

OPTIMISE TANK DESIGN USING CFD. Lisa Brown. Parsons Brinckerhoff

Force Main Condition Assessment: New Technologies & Case Studies

1. Water Line Maintenance 2. Sanitary Sewer Maintenance 3. Spill/Leak/Overflow Control, Response, and Containment

Most agencies think about cleaning because of debris in the line.

SECTION IV - TESTS AND INSPECTIONS PART 1 - GENERAL Testing - General

drinking water medication short guide

Hydraulic Pipeline Application Modules PSI s Tools to Support Pipeline Operation

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

SITE INSPECTION CHECKLIST

Emerging Sensing Technologies for Future Intelligent Water Management Systems

Asset Management Overview. Water & Wastewater Utility Operation and Management for Tribes

Transformer Deluge Systems

Leak detection in virtual DMA combining machine learning network monitoring and model based analysis

CONTROL OF LEGIONELLA AUDIT PROFORMA

CLEANING IN PLACE AUTOMATION FOR PROCESS INDUSTRY USING PLC AND SCADA SOFTWARE

How To Water System

Drinking Water and Wastewater Operator Certificate Programs

AWWA Small Systems Pipe Repair Checklist, as published in July 2008 Opflow Question of the Month

Well and Water System Disinfection For Private Wells

812-3 LIMITATIONS: b. No fire hydrant shall be obstructed or used when there is a fire in the area.

Corrosivity of Water Supplies

Inventory of Performance Monitoring Tools for Subsurface Monitoring of Radionuclide Contamination

Standard Hydraulic Piping Flushing Procedure

6. Principles of effective plumbing systems

Heating Water by Direct Steam Injection

CLEANING AND SANITIZING

SECTION 812 SEWER LINE, MANHOLE AND WET WELL CLEANING

SPRINKLER SYSTEM PLANS AND CALCULATIONS CHECK LIST

WASTEWATER TREATMENT OBJECTIVES

Training Calendar. December - March. Online Credit Classes* How to Register: January 4 - March 18, Online:

Dialysis Facility Disaster Plan Checklist

Transcription:

Modeling, GIS Software Optimizes Water Main Cleaning By Paul F. Boulos Close by Paul F. Boulos Maintaining the hydraulic and water quality integrity of drinking water distribution systems is a key concern for all water utilities. The hydraulic carrying capacity of water mains deteriorates with age, proportionate to the corrosive nature of the water and surrounding soils. Precipitation, microbiological activity and corrosion can all form deposits on the pipe walls. These accumulations increase the mains hydraulic roughness and reduce their cross-sectional area and hydraulic carrying capacity, which can lead to undesirable low pressures and inability to deliver fire flows, especially during high demand periods. Slow-moving water can also lose chlorine residuals at stagnant spots, creating a public health risk. Problems associated with water quality degradation are particularly acute in dead-end lines and lowdemand portions of water distribution systems. Flushing the water mains is an effective way to maintain water quality and system capacity. The procedure can improve water quality by restoring the disinfectant residual, reducing bacterial regrowth, dislodging biofilms, removing sediments and deposits, controlling corrosion, restoring flows and pressures (and overall system capacity), eliminating taste and odor problems, and reducing disinfectant demand throughout the system. These benefits prolong the life expectancy of the distribution system and reduce the potential for waterborne disease outbreaks. Unidirectional Flushing There are three general flushing methods (conventional, unidirectional, and continuous blow-off), but unidirectional flushing (UDF) is the most effective, resulting in both hydraulic and water quality improvements (Oberoi, 1994; Boulos et al., 2006; NRC, 2006).

Click here to enlarge image In this process, valves are closed and hydrants opened to create a one-way flow that removes built-up sediment in the water mains. This high-speed flushing (typically greater than or equal to 5 ft/sec) maximizes shear velocity near the pipe wall, producing a scouring action that effectively removes sediment deposits and biofilm. Although it is more costly and time consuming (requiring more planning) than conventional flushing, unidirectional flushing is more effective and requires about 40% less water. In addition, because unidirectional flushing tests almost all of the water system s valves and hydrants, it helps to identify those in need of repair or replacement. It can also reveal other distribution system problems, such as leaks and breaks.

Conventional flushing in a looped system results in water flowing toward the hydrant from all directions, generating lower flow velocity and less scouring of pipes. Click here to enlarge image Flushing should start at a clean water source (e.g., pump station) and proceed outward through the system so that flushing water is drawn from previously flushed reaches. This step-wise approach ensures that the mains are always being flushed with clean water, systematically washing out the pipes without pulling contaminants from other lines the way conventional flushing can. Optimizing Flushing UDF can be optimized through the use of hydraulic and water quality modeling and geographic information systems (GIS). The GIS is used to identify flushing zones, customer complaint locations, and the locations of valves, hydrants, pump stations, pressure-reducing valves, and other pertinent facilities. The hydraulic model is used to estimate pipe flow rates (magnitude and direction), velocities and flushing times. It also assesses the hydraulic impact of flushing sequences - information needed to avoid excessive pressure drops (e.g., below 20 psi) throughout the system while providing sufficient flushing velocity to scour solids from the pipes. The water quality model is especially useful for pointing out locations in the system that show excessive water age (i.e., long detention time). This combination gives utilities a visual tool to efficiently manage both water quantity and quality and distribution system assets such as pipes, hydrants and valves. Flushing Software InfoWater UDF, a new product from MWH Soft (Broomfield, CO), seamlessly integrates advanced network trace algorithms and dynamic water network (hydraulic and water quality) modeling with the latest generation of GIS technology. Built atop ArcGIS from ESRI (Redlands, CA), the application capitalizes on the intelligence and versatility of GIS geodatabase architecture to help water utilities develop optimal flushing routes, flushing logistics, and sequence of flushing zones; identify which fire hydrants and water main valves should be manipulated for proper cleaning; maintain the desired level of hydraulic performance in the system; and minimize labor and water usage. The program accurately considers the temporal variation in flow velocity magnitude and direction due to changes in demands, tank levels and pump operating conditions. It also computes minimum flushing time, total flushing volume and pipe length, flushing velocity of every pipe in the sequence, and available fire flow at the targeted minimum residual pressure. The hydraulic impact of each flushing sequence is also monitored to ensure that the desired minimum pressure is maintained throughout the system. Other advances include sophisticated statistical reporting capability, fully automated valve and hydrant operations, and flush sequence animation.

Unidirectional flushing results in water flowing toward the hydrant in only one direction, resulting in higher flow velocity, more scouring and better cleaning of pipes with less water use. Click here to enlarge image The product s comprehensive field journal (or flush book) contains all the information a water utility needs to implement a unidirectional flushing program for maximum cleaning with optimal cost savings. A detailed series of graphical maps and technical data sheets show the fire hydrants and valves that must be manipulated for systematic, unidirectional cleaning of each flushing zone and flush sequence analyzed. The field journal also reports important information such as pressure and flow, flushing volume and duration, and water quality. Conclusion InfoWater UDF can be an essential part of a good overall maintenance program, helping water utilities improve their distribution system s reliability, water quality and hydraulic capacity; assess system maintenance needs; meet regulatory requirements; reduce customer complaints; increase water savings; and sustain safer, more reliable drinking water supply infrastructures. This invaluable planning and monitoring tool can be used in many ways to develop, optimize and execute a distribution system flushing program. It has already been successfully applied by many progressive water utilities throughout the United States and Canada, producing noticeable improvements in flushing effectiveness and efficiency (Mazana et al., 2006) About the Author: Paul F. Boulos is the President and COO of MWH Soft (Broomfield, CO). A world-leading expert in water and wastewater engineering, Dr. Boulos has written over 200 articles and seven authoritative books, and has received a range of awards from the American Society of Civil Engineers, the American Water Works Association, and the US Environmental Protection Agency. He received his BS, MS and Ph.D in civil engineering from the University of Kentucky and his MBA from Harvard. He can be reached via e-mail at paul.boulos@mwhsoft.com. To access this Article, go to: http://www.waterworld.com/content/ww/en/articles/print/volume-23/issue-9/editorial-feature/modelinggis-software-optimizes-water-main-cleaning-by-paul-f-boulos.html

gis-software-optimizes-water-main-cleaning-by-paul-f-boulos.html