ITI Small Diameter (SD) external hex 3.25 / 3.3 external hex. ITI Standard 4.8 internal non-octagon Morse taper 4.



Similar documents
The IMZ Implant System

The IMZ Implant System

For Threadloc 3.75 (implant discontinued - components available in Branemark section) For Spline SD, RD & WD (only Locator components available)

NARROW DIAMETER implant

Screw-Vent MD 4.7 (4.5 Platform) MV 4.25 & 4.7, CV 4.5, BV 4.5 Tapered Screw-Vent 4.7 (4.5 Platform) 2.5mm internal hex

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

Implant Parts. A Radford Heath Guide 1

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment

AT THE RIGHT PRICE. ONE SIZE FITS ALL. FRICTION For a secure connection. BONEADAPT For immediate stability.

procedures & products NOBELESTHETICS including Procera

Gl GinGival level implant

Simpl Implant Abutments with Atlantis CAD CAM Technology

ERA. Attachment Systems. A SNAP to Use and Maintain

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM

Standard Internal Hex

GINGIVAL LEVEL implant

Straumann Dental Implant System. Fax Order Form Collection.*

All-on-4 treatment concept with NobelSpeedy Groovy

TRI-CAM Implant System

Product Catalog. ERA Mini TM Dental Implant System

MS SA Implant - Narrow Ridge MS SA Implant - Denture. MS Implant - Provisional MS KIT

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

Modern Tooth Replacement Strategies & Digital Workflow

Guidance for implant removal. Straumann Dental Implant System

Procedures & Products. NobelEsthetics

PROSTHETICS. Crown and Bridge Restorations with the synocta Prosthetic System DENTAL IMPLANT SYSTEM

ExFeel Internal Excellent Feeling, Excellent Implant!

Crown and Bridge Restorations. Straumann synocta Prosthetic System

PROSTHETICS. Crown and bridge restorations with the synocta prosthetic system.

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

. Simplification. High Performance. Safety and Longevity. The fundamental goal is to restore the quality of life of patients.

Straumann Bone Level Tapered Implant Peer-to-peer communication

Legacy3 System Overview Catalog. alog. 3.2mmD 3.7mmD 4.2mmD. Legacy mmD 5.2mmD 5.7mmD

STEP BY STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

Prosthetic Manual. Implant System. Contact Us: Smarter thinking. Simpler design. Phone: Fax:

DESS. Screws. Tijuana Ventas: (664) /95 For all major implant systems!!

Dental Implant Options in Atrophic Jaws

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

Encode Restorative System Procedure & Laboratory Manual

Straumann Dental Implant System. Implant Selection Guide.

GIVE YOUR PATIENTS THE FREEDOM TO EAT, SPEAK AND LAUGH AGAIN.

One Abutment - One Time

Straumann Dental implant system ONE SYSTEM ONE INSTRUMENT KIT ALL INDICATIONS*

IMPLANT DENTISTRY CLINICAL SYLLABUS

Product Catalog Comp lete Imp lant Solu tions

Restorative Guidelines

screw-retained single crowns using custom-cast abutments

Regular C/X Prosthetics. Prosthetics

prosthetic technique manual

PROSTHETIC OPTIONS FOR NARROW NECK IMPLANTS. Straumann Narrow Neck

More than a fixed rehabilitation.

Smile Confidently With DIEM 2. Immediate Full Arch Rehabilitation

Khaldoon G. Abu Afifeh, B.D.S, M. Sc in Prosthodontics

LOCATOR BAR ATTACHMENT SYSTEM

Lentur Cable System. Surgical Technique

Prosthodontist s Perspective

screw-retained crown using a PEEK temporary abutment

Self-Aligning Lowest Profile

OCT. Product Catalog. Bright Ideas in Dental Implants

SCD Case Study. Treatment Considerations for Implant Rehabilitation

NobelActive. procedures and products

ADA Insurance Codes for Laboratory Procedures:

Dental Implant Restoration

Restorative Manual Impression Transfer System

Straumann. Time-tested

Order of Treatment STEP-BY-STEP INSTRUCTIONS TO PLACE LOCATOR ATTACHMENTS

Content GENERAL INFO PRODUCT LIST SCREW SELECTION GUIDE PRODUCT TECH INFO. tech info. info ABOUT US & PRODUCTS 4 INTERNAL HEX UNIVERSAL TRILOBE

Abutment fracture in a bridge supported by natural teeth and implants

Clinical and Laboratory Procedures for Fixed Margin Implant Abutments

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

LOMAS / MONDEFIT ORTHODONTICS. The most innovative anchorage method for tooth correction

INTRODUCTION TO OSTEO-TI IMPLANTS; A NURSES MANUAL

STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment

platform shifting Nobel Biocare is shifting gingival beauty to the next level

A New Beginning with Dental Implants. A Guide to Understanding Your Treatment Options

Multi-unit abutment bar overdenture

ball abutment overdenture: chairside pick-up using existing denture

BEGO IMPLANT SYSTEMS PRODUCT CATALOGUE 2015 / Partners in Progress

Basic information on the surgical and prosthetic procedures. Straumann PURE Ceramic Implant

A Review of Implant Abutments - Abutment Classification to Aid Prosthetic Selection

Ridge Reconstruction for Implant Placement

Improving Esthetics with Sequential Treatment Planning and Implant-Retained Dentures

Like natural teeth. Treatment with dental implants is a safe, reliable and well-proven solution for permanently replacing one or more missing teeth.

03) Denture System - Ball Abutment - Magnetic Abutment (Sunken Type) - Magnetic Abutment (Flat Type)

LOCATOR Implant Attachment System for XiVE, FRIALIT and ANKYLOS Implants

United States. Product Catalog 2015

DENTAL IMPLANTS. Product Catalog SCIENCE OF AESTHETICS IMPLANTS

CORPORATE OVERVIEW... 3 PROSTHETIC PRODUCTS...20 RESTORATIVE PRODUCTS & TOOLS... 22

ATLANTIS abutments design guide CAD/CAM patient-specific abutments

páêçå~=aéåí~ä=`^al`^j=póëíéã på~åmçëí

Contact: Steve Hurson VP, R & D Nobel Biocare Savi Ranch Pkwy Yorba Linda, CA (714) steve.hurson@nobelbiocare.

DLT 123 CROWN AND BRIDGE

BICON DENTAL IMPLANTS

Implant Bar Overdenture Utilizing Locator Attachments

The SATURN implant by Cortex Dental Industries

2016 Buy Up Dental Care Plan Procedure List

Transcription:

ITI Standard Implant Dental Implant System The ITI Dental Implant System was developed in Switzerland by the Institute Straumann and Dr. ndre Schroeder, President of the University ern. ITI implants are endosseous onestage and were originally designed for overdentures using the Dolder ar system. ITI is now utilized for all restorative options. The one-stage (non-submerged) approach simplifies the procedures and helps minimize trauma to the patient and reduces chairtime as only one surgical procedure is required. The ITI implant system currently encompasses three different types of implants: ITI Small Diameter (SD) external hex 3.25 / 3.3 external hex ITI Compatible ITI Standard 4.8 internal non-octagon Morse taper 4.8 Platform / Neck ITI Syn-Octa 4.8 internal octagon Morse taper 4.8 Platform / Neck ITI Syn-Octa Implant Components made by ttachments International are available for the ITI Standard 4.8 internal non-octagon Morse taper and ITI Syn-Octa 4.8 internal octagon Morse taper. No components are currently available for the ITI SD external hex. Note: The ITI Standard components will mate with the ITI Syn-Octa implant without engaging the octagon. Implants ITI Small Diameter 3.25 / 3.3 external hex Restoratively Compatible To none ITI Standard 4.8 internal non-octagon Morse taper 3i TG Osseotite (4.8 Platform / Neck) Innova Endopore Internal Connection LifeCore Stage-1 ITI Syn-Octa 4.8 internal octagon Morse taper Zimmer SwissPlus (4.8 Platform / Neck) lue Sky io ø4.8mm Platform/Neck 2.0mm Thread Diameter ø4.8mm Platform/Neck 2.0mm Thread Diameter 3.0mm Octagon 16 16 2.0mm Thread 2.0mm Thread ITI Standard Internal ITI Syn-Octa Internal Non-Octagon Morse Taper Octagon Morse Taper 4.8 Platform / Neck 4.8 Platform / Neck 269

Terminology of Components ITI Page Header Sample Guide Direct To The Implant Healing Caps Direct Ti Posts Components listed on page Compatible Implant Name Restoration Connection Direct To The Implant Indirect Components Restorative Components: For ease in selecting components, the ITI Section is divided by Restoration Connection: Direct To The Implant or Indirect To n Intermediate Component (Tissue Extensions/butments). Overdenture ttachments, ar Systems, Individual Parts and Tools follow the Indirect Section. The Direct Restorative Components are the elements used to fabricate a restoration that will be connected directly to the implant(s). The Indirect / Intermediate Restorative Components fit to an intermediate tissue extension (Octabutment) which in turn is connected to the implant(s). Implant ody: The implant body is placed into the bone for approximately 4-6 months to allow for osseointegration. The implants should not be loaded prior to osseointegration. ITI Syn-Octa Octabutment: The Octabutment was designed for screw retained restorations and is compatible with the original Octabutment from Straumann. The shoulder of the Octabutment becomes flush with the top of the implant. Octabutment Compatibility: Implants ITI Small Diameter 3.25 / 3.3 external hex Restoratively Compatible To none ITI Standard 4.8 internal non-hex Morse taper 3i TG Osseotite (4.8 Platform / Neck) Innova Endopore Internal Connection LifeCore Stage-1 ITI Syn-Octa 4.8 internal octagon Morse taper Zimmer SwissPlus (4.8 Platform / Neck) lue Sky io 270

Straumann IMPLNT HELING CP to fit Internal Morse Taper compatible implants The implant healing caps fit directly to internal Morse taper connection implants and are used to cover the implant during the initial integration period. They are available in four lengths. 0mm SCS Direct Healing Caps UCL butment Direct Ti Posts closure screw is available for the 2 stage technique. The healing caps and closure screw require a IO-TORQ SCS (star) tip / driver. ITI Compatible Description (ll components manufactured by ttachments Int.) To Fit Order # Implant Healing Cap 2mm () H=2mm ø=4.9mm ITI compatible implants 33-502120 Implant Healing Cap 3mm H=3mm ø=4.9mm 33-502130 Implant Healing Cap 4mm H=4mm ø=4.9mm 33-502140 Implant Healing Cap 5mm H=5mm ø=4.9mm 33-502150 Implant Closure Screw, Star (SCS) 0mm () 33-500001 TOOLS RECOMMENDED: IO-TORQ Tip SCS (star), short 59-100173 IO-TORQ Tip SCS (star), long 59-100174 Optional: IO-TORQ dapter for ITI Torque Wrench 59-100192 UCL GOLD UTMENTS The UCL abutment system is the most widely used restorative concept. Engaging GOLD cylinders with a.050"/1.25mm hex screw are made to engage regular neck internal octagon Morse Taper implants. The non-engaging GOLD cylinder includes an.050"/1.25mm hex screw. Gold Description (ll components manufactured by ttachments Int.) To Fit Order # SwissTL RD UCL GOLD Engaging butment (red),.050"/1.25mm Hex Screw () Standard Internal Oct Morse Taper compatible 33-400502 SwissTL RD UCL GOLD Non-Engaging butment (white),.050"/1.25mm Hex Screw () Standard Internal Oct Morse Taper compatible 33-400552 TOOLS RECOMMENDED: IO-TORQ Tip Square.050", short.050"/1.25mm square screw 59-100180 IO-TORQ Tip Hex.050", short.050"/1.25mm hex screw 59-100120 Optional: IO-TORQ dapter for ITI Torque Wrench 59-100192 DIRECT TITNIUM POSTS to fit Internal Morse Taper compatible implants The direct titanium abutment posts screw into the implant body and are indicated for single units or bridge restorations. The tapered posts can be altered like a preparation. Fabricate a soft tissue model whenever preparations are made in the laboratory. If the final restoration is to be retrievable, consider using set screws. 4.0 5.5 7.0 Description (ll components manufactured by ttachments Int.) To Fit Order # Direct Titanium Posts 4.0mm Height ITI compatible implants 33-501240 Direct Titanium Posts 5.5mm Height 33-501255 Direct Titanium Posts 7.0mm Height 33-501270 TOOLS RECOMMENDED: IO-TORQ Post Insertion Tip Direct Titanium Post 59-100176 Optional: IO-TORQ dapter for ITI Torque Wrench 59-100192 Straumann is a federally registered trademark of Straumann Holding G Corp, Switzerland ITI is a federally registered trademark of Straumann Holding G Corp, Switzerland Copyright 2010 ttachments International, Inc., urlingame, C 271

Indirect Octabutment OCTUTMENT COMPONENTS OCTUTMENT The Octabutment was designed for screw retained single tooth or bridge restorations. The Octabutment has an external octagon and a tapered mating surface that securely locks with the implant when torqued into place. The Octabutment is available only in one length. Restorations can be made on the abutment using abutment cylinders. The Impression Coping takes an impression of the abutment and transfers the implant position and thread timing. The nalog is a replica of the abutment and is used for fabrication of a master model. The Cylinders are available either with an internal octagon for single tooth restorations or non-octagonal for crown & bridge or bar restorations. To attach the abutment use the IO-TORQ or LT/R tips. Refer to the Direct Section for restorations that fit to the implant directly. C D D E E Impression Coping nalog Temp Octabutment Temp Non-octagon Octagon Cylinder Non-Octagon Cylinder Description (ll components manufactured by ttachments Int.) Intended Use Order # C D E Octabutment 1 piece Tissue Extension / butment Octabutment, Titanium 33-500010 Components To Fit Octabutment / Tissue Extension Impression Coping 2 piece Open Tray Impression Taking / Transfer Timing Octabutment Impression Coping & Star Guide Pin Transfer thread timing 33-500099 nalog Model Fabrication Octabutment nalog, Stainless 33-500015 Temporary butments Crown & ridge / ar Restorations Temporary Octabutment & Star screw 33-500309 Temporary Non-octagon abutment & Star screw 33-500359 Cylinders and Screws Crown & ridge / ar Restorations Octagon cylinder (blue) & Star screw 33-500209 Non-Octagon cylinder (white) & Star screw 33-500259 Protector Cap Octabutment Protector Cap & Star screw 33-502109 PRTS Octagon cylinder only, blue 33-500200 Non-Octagon cylinder only, white 33-500250 Star screw only, for Octabutment (compatible with SCS driver) 33-500059 TOOLS IO-TORQ Tip Octabutment Insertion of Octabutment 59-100175 IO-TORQ Post Insertion Tip Insertion of Direct Titanium Post 59-100176 IO-TORQ Tip SCS (star), short Insertion of Fixation Screws (starlike) 59-100173 IO-TORQ Tip SCS (star), long 59-100174 NOTE: Prior to Sept. 2001, the square screws for the Octabutment were.045", then.050". ll screws are currently Star screws, compatible with SCS driver. 272

SCREWS & GUIDE PIN To Fit Octabutment The screws and guide pins for the Octabutment are used to fasten the restoration to the Octabutment and are made of Indirect Individual Screws & Guide Pins titanium alloy. The star screws and star guide pins require a IO-TORQ SCS (star) tip / driver. ITI Compatible Description (ll components manufactured by ttachments Int.) Intended Use Order # Screws* Star screw only (compatible with SCS driver) for Octabutment () 33-500059 Guide Pins Star Guide Pin for Octabutment 10mm () 33-500069-10 Star Guide Pin for Octabutment 12mm 33-500069-12 Star Guide Pin for Octabutment 14mm 33-500069-14 Star Guide Pin for Octabutment 16mm 33-500069-16 Star Guide Pin for Octabutment 20mm 33-500069-20 Protector Cap Octabutment Protector Cap & Star screw 33-502109 Tools IO-TORQ Tip Octabutment Insertion of Octabutment 59-100175 IO-TORQ Post Insertion Tip Insertion of Direct Titanium Post 59-100176 IO-TORQ Tip SCS (star), short Insertion of Fixation Screws (starlike) 59-100173 IO-TORQ Tip SCS (star), long 59-100174 IO-TORQ dapter for ITI Torque Wrench 59-100192 IO-TORQ io-ratchet 59-100000 *NOTE: Prior to Sept. 2001, the square screws for the Octabutment were.045", then.050". ll screws are currently Star screws, compatible with SCS driver. 273

Overdenture ttachments D ORS llegro Implant Female Kit lternative for D C DS & ORS OVERDENTURE STUD TYPE TTCHMENTS The Dalla ona and ORS, O-Ring system, are popular overdenture attachments that directly screw into the implant. 1 gold plated retainer ring, 3 white final & 3 red processing for the Dalla ona system. The ORS Female Kit includes oth connectors are made of titanium. The Dalla ona male O-Rings and 1 brass analog. (2.2mm ø) and the ORS male (2.2mm ø) are sold separately. The retention of the Dalla ona female is adjustable with The D Female Kit includes 1 adjustable female, 1 spacer the activating or deactivating tool. and 1 brass analog. The llegro Female Kit is an optional kit Description (ll components manufactured by ttachments Int.) Tissue Height Order # Dalla ona for ITI Implants () Dalla ona, male only 0mm 33-543003 Dalla ona, Implant Ti Female Kit, includes Female, Spacer & nalog 40-430002 llegro, Implant Female Kit (alternative for Dalla ona female) () 40-730002 includes Metal Housing, 4 Females, Implant Spacer & rass nalog ORS, O-Ring System for ITI Implants (C) ORS, male only 0mm 33-544003 ORS, Implant Female Kit, includes Retainer Ring, nalog & 3 red processing & 3 white final O-Rings 40-440002 Note: The Dalla ona and ORS for ITI / Morse Taper compatible implants are considered zero tissue height as the shoulder of the male cuff is flush with the top of the implant. No other heights are available. TOOLS (for a complete list of Dalla ona, llegro & ORS Tools and Parts see next page) Dalla ona/ors IO-TORQ Tip 59-100140 IO-TORQ dapter for ITI Torque Wrench 59-100192 LT / R Handle 58-100190 LT / R ORS / Dalla ona Tip 58-100140 Dalla ona ctivating Tool, lue 99-451017 Dalla ona Deactivating Tool, Yellow 99-451018 274

Dalla ona & ORS OVERDENTURE STUD TYPE TTCHMENTS Two types of overdenture attachments are most commonly used to directly screw into the ITI implant the Dalla ona, and the ORS (O-Ring system). Connectors are made of titanium. Dalla ona and ORS males are sold separately by tissue height. The D Female Kit includes 1 adjustable female, Parts & Tools for Overdenture ttachments 1 spacer and 1 brass analog.the llegro Female Kit is an optional kit for the Dalla ona system. The ORS Female Kit includes 1 gold plated retainer ring, 3 white final & 3 red processing O-Rings and 1 brass analog. PRTS Description (ll components manufactured by ttachments Int.) Dimensions Order # DLL ON FOR IMPLNTS Dalla ona, Implant Female Kit: includes Female, Spacer & rass nalog 40-430002 Dalla ona, Resilient Female, Gold FH=3.1mm 97-430282 Dalla ona, Resilient Female, Titanium FH=3.4mm 99-451012 Dalla ona, Resilient Female, Plastic (4) FH=3.5mm 99-430282 Dalla ona Hex nalog, rass (2) 40-430017 Dalla ona Hex Spacer, rass (2) 40-430016 PVC Ring (6), replacement ring for Dalla ona female 97-430200 llegro, Implant Female Kit (alternative for Dalla ona female) 40-730002 includes Metal Housing, 4 Females, Spacer & rass nalog ITI Compatible ORS FOR IMPLNTS ORS, Retainer Rings (6) H=2.0mm ø=5.1mm 99-440044 ORS, Combo O-Rings (24): 6 blue, 6 red (processing), 6 wt, 6 blk Outside ø=4.5mm Inside ø=1.4mm 99-443037 ORS, Implant Female Kit: includes Retainer Ring, rass nalog and 3 red processing & 3 white final O-Rings 40-440002 O-Ring Hex nalog, rass (2) 40-440017 TOOLS IO-TORQ Wrenches, Socket & Driver IO-TORQ Wrench 10 N/cm 59-100010 IO-TORQ Wrench 20 N/cm 59-100020 IO-TORQ Wrench 30 N/cm 59-100030 IO-TORQ Wrench 35 N/cm 59-100035 IO-TORQ Hand Held Socket, swivel head (16.3mm Height) 59-100190 IO-TORQ Hand Held Socket, short (8.1mm Height) 59-100191 IO-TORQ Extension 59-100195 IO-TORQ ORS / Dalla ona Tip/Driver 59-100140 IO-TORQ dapter for ITI Torque Wrench 59-100192 LT/R DRIVER LT/R R Hand Driver 58-100000 LT/R R Handle / Socket 58-100190 LT/ R ORS / Dalla ona Tip 58-100140 DLL ON Dalla ona ctivating Tool, lue 99-451017 Dalla ona Deactivating Tool, Yellow 99-451018 LLEGRO (for replacement parts see llegro OD section page 99) llegro OD/DE Micro/Regular Insertion Tool 73-410162 Dalla ona ctivating Tool Dalla ona Deactivating Tool 275

Straumann Insertion Drivers INSERTION DRIVERS ND IO-TORQ WRENCHES & DRIVERS The IO-TORQ (-T) System was designed to facilitate the insertion of implant components. The IO-TORQ insertion tips/drivers may be utilized with the IO-TORQ hand held socket or the IO-TORQ wrenches. n adapter for Straumann / ITI Torque Wrench is available. IO-TORQ C D E F Socket Short Socket Extension SCS Octa Post Description (ll components manufactured by ttachments Int.) Order # IO-TORQ Hand Held Socket / Handle, Swivel Head (16.3mm Height) () 59-100190 IO-TORQ Hand Held Socket / Handle, Short (8.1mm) () 59-100191 IO-TORQ Extension (C) 59-100195 IO-TORQ dapter for Straumann / ITI Torque Wrench 59-100192 IO-TORQ Dalla ona / ORS Hex 2.5mm Tip 59-100140 IO-TORQ Tip SCS (star), Short 59-100173 IO-TORQ Tip SCS (star), Long (D) 59-100174 IO-TORQ Octabutment Tip (E) 59-100175 IO-TORQ Direct Titanium Post Insertion Tip (F) 59-100176 NOTE: Prior to Sept. 2001, the square screws for the Octabutment were.045", then.050". ll screws are currently Star screws, compatible with SCS driver. IO-TORQ Wrenches IO-TORQ Wrench 10 N/cm 59-100010 IO-TORQ Wrench 20 N/cm 59-100020 IO-TORQ Wrench 30 N/cm 59-100030 IO-TORQ Wrench 35 N/cm 59-100035 IO-TORQ dapter for Straumann / ITI Torque Wrench 59-100192 IO-TORQ io-ratchet 59-100000 IO-TORQ dapter for Straumann / ITI Torque Wrench 59-100192 Straumann is a federally registered trademark of Straumann Holding G Corp, Switzerland ITI is a federally registered trademark of Straumann Holding G Corp, Switzerland Copyright 2010 ttachments International, Inc., urlingame, C 276