Using Robotics for Non-Destructive Examination & Characterization of. Hazardous Storage Tanks



Similar documents
Robotic Tank Inspection End Effector

Nondestructive Testing and Evaluation of Steel Bridges

Heat Exchanger Thin Film Foul Release Applications Corrosion Resistant Protective Coatings Grit Blast Surface Prep of Tubular Equipment

Health Care for Pipelines From Cradle to Grave

11. NONDESTRUCTIVE TESTING

TURBINE ENGINE LIFE MANAGEMENT App. N AIAA AIRCRAFT ENGINE DESIGN

for boilers From selecting the best NDT technique to monitoring inspection quality

City facilities that are currently part of the System are listed below. Other City facilities may be added in the future.

Analytical Products and Solutions. Complete service and maintenance solutions for your analytical equipment. usa.siemens.com/analyticalproducts

Intelligent Measurement and Diagnostic Techniques for Non-destructive Inspections

NON DESTRUCTIVE TESTING & ASNT WELD INSPECTION & AWS

Reach Higher with Inspection Academy GE s Inspection Technologies Global Knowledge Center.

SECTION 1 GENERAL REQUIREMENTS

RGC-IR Remote Gas Calibrator for IR400

Nondestructive Testing: Why, When, What and How?

Non-Destructive Testing

FPO. Meeting and Exceeding API Standards: How Much Testing Do Pumps Really Need? White Paper

Introducing AUDIT-BUDDY

Field Application Note

2005 WJTA American Waterjet Conference August 21-23, 2005 Houston, Texas Paper SAFE WATERJET CLEANING OF STEEL PROCESS LINES

NON-DESTRUCTIVE TESTING OF PIPELINES. L. Annila. Abstract

Automotive Applications of 3D Laser Scanning Introduction

Industrial Robotics. Training Objective

BARE PCB INSPECTION BY MEAN OF ECT TECHNIQUE WITH SPIN-VALVE GMR SENSOR

Technical Notes NDT 001 Specific Requirements for Non- Destructive Testing Laboratories

The Analysis of Quality Escapes in the Aerospace & Defense Industry

NCCER Progress Blvd., Alachua, FL Tel: (888) Task Number Item Date(s) Recorded By

Time is Money: Justifying the Switch to Automated Time Collection

Ultrasonic Wave Propagation Review

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

INNOVATIVE ELECTROMAGNETIC SENSORS

Electrical Classification

Phased-Array ROWA-SPA: High-performance testing machine for combined, 100-percent automated testing of square and round bars

Non-Destructive Testing

HIGH-RESOLUTION LED MODULES PERFECT VISUAL SOLUTIONS

THE ULTRASONIC TOMOGRAPHY TESTS OF CONCRETE IN FOUNDATION SLAB

The UniWest 4D Rapid Prototype Product Development System. Use mouse or arrow keys to scroll through presentation.

Eddy-current testing - Non-destructive testing for flaw detection of metals, coatings and carbon fibres

RC4000: Vehicle Monitoring Radiation Detection Systems

Tube Control Measurement, Sorting Modular System for Glass Tube

REDUCING UNCERTAINTY IN SOLAR ENERGY ESTIMATES

ADVANCED NDT TECHNIQUES FOR PLASTIC PIPELINE INSPECTION

DEVELOPMENT OF PROCESS TEMPLATES AS A PROJECT MANAGEMENT TOOL FOR THE PLUTONIUM FINISHING PLANT

Emerging NDE Technology for Aging Aircraft Large Area Scanning To Small High Resolution Systems Maintenance Planning Tools

Fluid structure interaction of a vibrating circular plate in a bounded fluid volume: simulation and experiment

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

April 15, 2011 VIA ELECTRONIC TRANSMISSION

Houston Service Center Medium Voltage Service and Aftermarket Solutions

Automated Infrared Thermography Complete Solutions from a Single Source

Pipeline External Corrosion Analysis Using a 3D Laser Scanner

Light Duty Commercial Electric Water Heater

Nuclear Safety Council Instruction number IS- 23 on in-service inspection at nuclear power plants

DECOMMISSIONING THE BROOKHAVEN NATIONAL LABORATORY BUILDING 830 GAMMA IRRADIATION FACILITY

PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany

CURRENT EXPERIENCE IN TYPICAL PROBLEMS AND FAILURES WITH BOILER PIPING COMPONENTS AND SUPPORTS

Visual Servoing Methodology for Selective Tree Pruning by Human-Robot Collaborative System

Knowledge Base Data Warehouse Methodology

Understanding the Flo-Dar Flow Measuring System

Lessons Learned during the Refurbishment and Testing of an Observatory after Longterm

NON-DESTRUCTIVE TESTING FULL SCOPE OF INTEGRATED NDT SERVICES

INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM

APPENDIX CC NUCLEAR WASTE STORAGE

Compaq Rack Options and Accessories. Monitors and Keyboards

E190Q Lecture 5 Autonomous Robot Navigation

Appendix O MANUFACTURING YOUTH APPRENTICESHIP PRODUCTION OPERATIONS MANAGEMENT PATHWAY PRODUCTION OPERATIONS MANAGEMENT (UNIT 8)

WARNING! Failure to follow these inspection procedures can cause personal injury and property damage.

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

Lamination Production. by: John Roberts / Sko Die, Inc

ETCAL Level 3 NVQ Diploma in Engineering Technical Support (QCF) Qualification No 600/2285/1 Credit Value 80 GLH 311. Qualification Structure

VISUAL INSPECTION SYSTEMS

DIVERSIFICATION INTEGRITY MARKETS SERVED BUILT ON BUILT ON

Good Boards = Results

CITY OF BEAUFORT SOLICITING SEALED PROPOSALS FOR MOBILE REFUSE CARTS

Roof Maintenance Scope of Work

Leak detection of systems

PRECISION METAL STAMPINGS & ASSEMBLIES FOR THE MEDICAL DEVICE INDUSTRY

CEP Discussion: AREVA s SONGS-Specific Used Fuel Solution

A.1 Sensor Calibration Considerations

cbperformance.com Please read this entire brochure prior to installing your CB Performance Products MAGNASPARK II distributor.

STANDARD OPERATING PROCEDURES Safe Autoclave Operations

Qualification of In-service Inspections of NPP Primary Circuit Components

NRC s Program for Remediating Polluted Sites J.T. Greeves, D.A. Orlando, J.T. Buckley, G.N. Gnugnoli, R.L. Johnson US Nuclear Regulatory Commission

Introduction to Standards and Nondestructive Testing of Industrial Materials

Industrial Metrology and Engineering Applications in the Wind Turbine Industry

Pharmaceutical Rotary Presses. PharmaPress 800. High Speed Double Rotary Press

APPENDIX 2-3 PCAPP EDS INSPECTION LOG SHEETS

NDT Procedure for Liquid Penetrant Inspection

Plant components, selected for sound performance

powered by ingenuity Corrosion Logging Well Integrity Measurement

Mine & IED Roller Solutions Route Clearance, Anti-Tank, Dismounted, Area Clearance

Prevention through Design: Eliminating Confined Spaces and Minimizing Hazards

SUPPLIER QUALITY PROGRAM, V (U)

Leading Today s Technology in Injection Molding

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Transcription:

Robotic End Effector For Inspection of Storage Tanks (FETC DE-AR21-93MC30363) Using Robotics for Non-Destructive Examination & Characterization of Hazardous Storage Tanks R. Beer (rbeer@oss.oceaneering.com, 281-228-5414) Oceaneering Space Systems 16665 Space Center Blvd Houston, TX 77058-2268 Abstract Oceaneering Space Systems (OSS) has supported robotic non-destructive evaluation (NDE) inspection and characterization initiatives in partnership with the Federal Energy Technology Center (FETC). During the program OSS developed a robotic electromagnetic NDE system that successfully deployed in February 1999 inside INEEL s Tank WM188. A similar fast-track design and development approach yielded another highly successful waste inspection and retrieval tool deployed in Savannah River s tank 16 in June 1998. Close communication between FETC, OSS, and the DOE sites allowed technology development on a short schedule and ready to go out of the box. Preparation for these deployments included: user-based design evaluation, extensive systems integration, & operations planning, all of which contributed significantly to deployment success. Even with these strategies, however, uncertainties in deployment, shifting customer requirements, and difficulties in manipulator integration posed unique challenges. These lessons will be explored so they may be applied to new programs seeking to advance a technology s state-of-the-art within the multi-site/multiuser environment of the DOE.

Introduction Beginning in 1993, OSS began developing a non-destructive testing end effector for inspection of hazardous underground storage tanks in the Tanks Focus Area. Several DOE sites contain suspected leaking underground tanks, all of which need inspection. The tanks are predominantly stainless steel or carbon steel, and many are approaching the end of their operational lifetime. Given the magnitude of the problem, automated and efficient inspection methods utilizing site-specific robotics platforms were required. To meet this challenge, FETC and OSS agreed to the following criteria: The electromagnetic inspection system must introduce no secondary waste, it couldn t be a spark or ignition hazard due to the combustible gasses in certain tanks, and had to deploy on existing robotics platforms within the DOE. The system was expected to be radiation hardened, sealed for decontamination showers, and contain both an NDE sensor suite and a video camera with lighting. The NDE system had to be capable of accurate, repeatable detection and sizing of crack and pit tank-wall defects as small as 1/8 inch in length or diameter. Approach This technology deployment program obviously had to meet rigorous design specifications for a difficult job within a harsh deployment environment. In addition, universal acceptance from numerous stakeholders within the Tanks Focus Area, many of which came from different labs, was vital. Weighing these significant challenges led OSS to pursue an aggressive strategy ensuring inspection success, customer acceptance, and consistent design direction for a technology development program that could land at any DOE site within the Tanks focus area. To aid in this matter, numerous meetings at Hanford, INEEL, and Houston occurred during the development process ensuring that all relevant parties had an appropriate level of design input. For example, Light Duty Utility Arm operators & NDE experts from both Hanford & INEEL met with OSS engineers at various stages in the design and development processes. These meetings proved time

well spent when the system s hot deployment was completed without any delays, interruptions, or difficulties. Another success strategy involved a heavy emphasis on testing from the subsystem level up to integration tests between the end effector and the LDUA. Rigorous software and hardware burn-in testing throughout the program enabled delivery of an inspection system that was ready to go out of the box with no surprises. Additionally, close communication between OSS and FETC minimized feature creep -- the steady addition of product features and requirements that can plague a multiyear technology development program. Finally, the importance of vivid, well-lighted video was not overlooked. Care was taken during the design process to include a color video camera and lighting to ensure the NDE inspection data was coupled with a clear view of the surface being tested. Technology Oceaneering Space Systems chose Alternating Current Field Measurement, or ACFM, to meet the DOE s inspection challenge because of the technique s inherent suitability for inspecting ferrous materials. The OSSdeveloped system performs a noncontact inspection by energizing coils to excite a uniform current field in the tank wall. As the current field flows around cracks or pits, it creates a disturbance in the magnetic field normal, or perpendicular, to the tank wall. An array of sensing coils and the control electronics read the disturbance, resolving its location and the crack length or pit diameter. This information, along with material properties of the tank-wall alloy, is then used to compute defect depth from a three-dimensional electromagnetic field model of the disturbance. This technique eliminates the need for calibration runs typical to eddy-current applications, and is much less sensitive to sensor-to-wall standoff and orientation issues. Since electrical contact with the tank surface is not required for ACFM, pre-inspection cleaning of the tank-wall surface is unnecessary. Other inspection methods were not considered due to their inherent disadvantages, such as requirements for surface cleaning (dye-

penetrate), use of secondary waste (coupling fluid for ultrasonic scans), or ambiguous data interpretation (reading x-ray films.) The hot tank environment also drove the system s design. Since the end effector is deployable into extremely radioactive tanks, radiation tolerance is vital. The operating environment was assumed to be at least 1.0x10 6 rad. Thermal variations resulting from seasonal deployments in the Tanks Focus Area also had to be accounted for. The expected thermal environment ranges from 0 to 50º C. System specifications are listed in Table 1. Table 1: End Effector Specifications Defect Sizing Range*... 0.25 to 1.8 in. *Smaller or larger defects sizable with different coil configurations Defect Sizing Accuracy...± 0.060 or 10% Operating Environment Radiation Tolerance... 1.0x10 6 rad Operating Temp.... 0 to 50 C Size...10.5 in. OD x 19.4 in. Weight...45 lbs. Umbilical... 1.25 by 300 Power... 500 Watts Interface... mounts to robot tool plate A detailed description of the end effector s design, operational history, performance, and specifications are described in detail in Reference 2. Figure 1. Non-Destructive Evaluation End Effector produced by Oceaneering Space Systems. The end effector, pictured in Figure 1, was designed to interface with the Light Duty Utility Arm (LDUA) described in Reference 1. To ensure integration success, tool interface plates between the end effector and the LDUA were provided by Hanford and INEEL during hardware development. Figure 2 shows a schematic of the end effector s major components. Obviously, deploying robotic inspection systems involves much more than just the remote inspection tool. The complete system includes the end effector, at-tank electronics modules, remote inspection workstation, umbilical data & power lines, and an intuitive, windows-based, custom NDE software

package installed on the operator s console. Far Light Camera Near Light Sensing Array Scanning Frame Motor for Indexing Array Landing Strut Figure 2. End Effector Schematic Results The first prototype of the end effector was successfully demonstrated at Hanford in February of 1997. Suggestions for operational improvements and modifications for increasing radiation hardness led to a design revision that produced the end effector pictured in Figure 1. Following production of the updated end effector, the complete system was delivered to INEEL in May of 1998. Testing at OSS prior to delivery and upon receipt at INEEL confirmed the inspection system was able to detect and size 100% of the cracks and pits within the customer s requested defect-sizing range. For verification purposes, stainless steel and carbon steel test coupons with stressinduced flaws were produced and their defects verified using X-ray characterization. INEEL-requested operational modifications to the design were also completed - allowing surface inspection below the liquid/sludge layer. Lines were pressurized, seals upgraded, and the end effector was dunk-tested. (It should also be noted that significant shipping damage occurred during delivery. Repair on-site rectified the situation, but future deployments warrant shipment by OSS personnel.) Final deployment occurred at INEEL in February of 1999 inside tank WM188. The system performed flawlessly, returning excellent NDE scans of tank surfaces and weld lines, along with detailed video of the inspected surfaces. The uniform acceptance of both the inspection system and its control software confirmed the importance of including operators, site representatives, and safety personnel early in the design process. Furthermore, the ease of operation for

site personnel proved our threefold strategy of providing: an intuitive iconbased graphical user interface, a detailed Users Manual (Reference 4), and frequent training opportunities with OSS personnel at the site prior to deployment. Benefits Benefits of employing nondestructive evaluation to inspect underground hazardous waste storage tanks, especially those suspected of leaking radioactive waste, are obvious. The particular electromagnetic NDE method chosen by OSS was deemed optimal for the DOE s needs. ACFM is the only inspection system currently capable of performing fly-by inspections that quickly sweep the interior of a tank -- logging suspect sites and returning to only those sites for the more time-consuming detailed scan. This benefit alone will save the DOE significant time and expense during labor intensive hot tank deployments. The other technical benefits, including superior performance and no secondary waste introduction, as compared to other inspection modalities were summarized above in the Technology section. A detailed explanation of ACFM and comparison to other NDE techniques is included in Reference 3. Benefits from Oceaneering Space Systems project management strategy of including site operators, NDE experts, and safety representatives in the design, testing, and fielding phases of the technology development program included: universal acceptance, fasttrack scheduling, smooth deployment operations (including no inspection delays), and bilateral confidence in OSS inspection data. Future Activities The NDE End Effector resides at INEEL within the Tanks Focus Area inventory. Any future deployments at the site where vivid visual inspection and accurate defect sizing are required, will no doubt employ this highly useful tool.

References Acknowledgements 1. Innovative Technology Summary Report: Light Duty Utility Arm, DOE/EM-0406, OST Reference #85, December 1998 2. Final Report: Robotic Tank Inspection End Effector, Contract No. DE-AR21-93MC30363, Document # 21100-70004, October 1991 3. Hughes, G., and Gittleman, M.M., A Robotic End Effector for Visual and Electromagnetic Inspection of Waste Storage Tank Walls, Proceedings of the ANS 6 th Topical Meeting on Robotics and Remote Systems, 347-354. American Nuclear Society, Inc. La Grange Park, IL, 1995. 4. Robotic Tank Inspection End Effector (RTIEE) Software Users Guide Version 2.0, Contract No. DE-AR21-93MC30363, Document #21100-70003, April 1998 OSS would like to thank Ms. Maria Vargas, the FETC Contracting Officer s Representative (COR), for her guidance and support. OSS would also like to thank the personnel at Hanford and INEEL who, through their input, helped transform the NDE End Effector from a technology demonstration into a vital inspection tool.