+by RGF A Guardian Air Purification System New Advanced Environmental Air Treatment System



Similar documents
REME HALO by RGF A Guardian Air Purification System New Advanced Environmental Air Treatment System

Copyright Puradigm, LLC HVAC Owner s Manual

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Installation Instructions WARNING: WARNING: WARNING: WARNING: WARNING:

Owner s Manual Model 5000 Safety, Operating and Maintenance Instructions

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Installation and Operating Instructions (for chargers shown below)

Dehumidifier Users manual. For Models: DH45S DH65S

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

Installation and Operating Instructions (for chargers shown below)

UV100A Ultraviolet Air Treatment System

Service Guide. Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines. ORDER No: UN-SVG001A-EN DATE: October 9, 2007

RC930 Manual 6/10/99 1:23 PM Page 1. Wireless Modem Jack

GENANO 4500 MEDICAL AIR PURIFICATION DEVICE

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

STC 3S A Series Solenoid Valves

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

PROFESSIONAL SILK CERAMIC HAIR DRYER USE & CARE MANUAL PLEASE READ PRIOR TO USE 2400 WATTS SILK CERAMIC GRILLE 5 YEAR WARRANTY AC9096AU

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Installation Instructions

Installation Instructions for Alarm Module Kit A043F059

PowerStar Mini Triple Play TM

3 WATT LED SPOTLIGHT Model No. SLM

AROS SMART WINDOW AIR CONDITIONER

Congratulations on your purchase of the Great Planes SLOT MACHINE, the first truly easy way to cut hinge slots in your model airplanes.

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Operating Guide Manuel de l utilisateur

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

2013 VTech Printed in China US


Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

VK-250 WARRANTY REGISTRATION FORM

Meaco 30L and Meaco 40L dehumidifier instruction manual

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Cooktop Low-Profile Ventilation Hoods

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Advantium 2 Plus Alarm

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Safety, Operation and Maintenance Manual with Parts List

Water Leak Detection System

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

Refer installation of power supplies to qualified service personnel.

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

Bubble King. User Manual

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Tablet 30W Tablet 92W

WH/WIH/WIHD/WIHD&M/WIHL AND WIH SERIES

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

The Storm 20-Gallon Wet/Dry Vac

BroadBand PowerShield. User Manual

Instruction Manual. Window Wiper AFW900. (Read carefully before use)

There are several types of air cleaning devices available, each designed to remove certain types of pollutants.

Coway Air Purifier AP-1008DH

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

, User s Manual

SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / Instruction Manual. Page 1 of 9

Air Conditioning Systems Warranty Manual. Version 1.8

PORTABLE AIR CONDITIONER CLIMATISEUR PORTATIF ACONDICIONADOR DE AIRE PORTATIL

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

2 YEAR WARRANTY S7200PAU USE & CARE MANUAL ADVANCED CERAMIC TECHNOLOGY. To register your product go to

FOXAIR 60/50 ALL MODELS

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Indoor Remote Controlled Power Points

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Rechargeable Spotlight

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Product Support: Contact Virus Zero at Sales Inquiries: Contact Sylvane at (800) or visit sylvane.com

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

Multi Tube Rotator. Model No. 4632Q CE CECN /05/11

Multi-Pitch Pitching Machine USER MANUAL

AROS SMART WINDOW AIR CONDITIONER

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

5800 Temperature Sensor Cable Assembly

Hot Water Central. Electric Hot Water Dispenser. Instruction Manual AAP-325W.

USER S MANUAL HSC-24A

Alarm Clock USER GUIDE

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Installation Guide of Sunrise Solartech PV Modules. Term Contents. Purpose of this guide. General. Safety precaution for installing a solar

MultiDim MKII V.2 ORDERCODE 50386

Automatic Phone-Out Home Monitoring Systems

ROTOR LOADER OWNER S MANUAL

24.2L M.A.N. V12 Engine Module

Transcription:

REME TM +by RGF A Guardian Air Purification System New Advanced Environmental Air Treatment System Thank you for purchasing the REME TM + By RGF Environmental Group, Inc. We are confident this system will provide you with years of Fresh, Clean and Odor-Free Air!!! NOTE: Please take time to read the attached assembly instructions. All instructions and precautions should be adhered to while operating this system. RGF Environmental Group Copyright 2008

The REME TM + by RGF The REME TM + by RGF Environmental Group is designed to help eliminate sick building syndrome risks by reducing odors, air pollutants, VOCs (chemical odors), smoke, mold, bacteria and viruses. The HVAC REME TM units are easily mounted into existing air conditioning and heating system air ducts where most sick building problems start. When the HVAC system is in operation the HVAC-REME TM + cell creates an Advanced Oxidation Process consisting of: Ionized Hydro-peroxides, superoxide ions and hydroxide ions. All are friendly oxidizers. By friendly oxidizers we mean oxidizers that revert back to oxygen and hydrogen after the oxidation of the pollutant. Typical Installation Ducts Guardian Air REME TM Cooling Coil Aggressive Charged Advanced Oxidation Purifiers Fan Remote Power Supply Figure 1 Bacteria, Mold and Virus REME TM Cell Features Catalytic Coating Electronic Housing UV-IR Long Life Cell Silent Plasma Propulsion Module (SPPM TM ) Figure 2

REME TM CELL by RGF INSTALLATION INSTRUCTIONS CAUTION: NEVER DISASSEMBLE A REME UNIT WHILE IT IS CONNECTED TO POWER. THIS DEVICE PRODUCES BROAD SPECTRUM UV LIGHT AND WILL CAUSE DAMAGE TO EYES. Your kit contains the following: Guardian Air REME TM HVAC unit with adhesive backed mounting plate Remote mounted switching power supply (Input: 100-240 Volts AC, Output: 12 VDC) Adhesive backed foil mounting ring Four (4) mounting screws Instructions and warranty card NOTE: DO NOT USE UNIT IF POWER CORD IS DAMAGED. PLUG MUST BE ACCESSIBLE AT ALL TIMES. INSTALLATION INSTRUCTIONS: 1. Determine the Mounting Location: To maximize the effectiveness of the Guardian Air REME TM Cell it is recommended to install the Guardian Air REME TM unit in the air plenum just after the air handling unit (supply side), refer to Figure 1 for clarification. As drilling/cutting holes into the duct are required, it is recommended to install the Guardian Air REME TM unit outside any existing HVAC air handling unit (this will prevent any possible damages to the HVAC unit during the installation process). When locating the unit, always allow for positioning near a suitable power source (i.e., When using a standard 120 volt source, be sure to position the unit in close proximity to an existing outlet). Once a suitable location is determined, position the Guardian Air REME TM midway in your air duct (make sure you have allowed enough room to accommodate the 5-1/2 round mounting plate when finalizing your mounting position). Be sure to position the unit so that the embossed arrow on the mounting plate is pointed in the direction of the air flow within the duct.

Using a 3.25 hole saw (or other suitable means) cut a 3.25 hole into the plenum / duct box. Cutting into fiberboard is usually easier than metal, and can typically be done with a utility knife (Figure 3). Be sure you are drilling into the ductwork only and not penetrating into the mechanical areas of your HVAC system. Figure 3 2. Mounting Unit: Secure the mounting plate to the air duct by first peeling the paper backing off the selfadhesive sealing ring affixed to the back side of the mounting plate (be sure the mating area of the duct surface is flat, clean and dry), refer to Figure 4. Figure 4

Insert probe into opening with the arrow indicator going in the same direction as the airflow of the hvac unit. Once attached to duct, press firmly all around flange to ensure a proper seal, refer to Figure 5. Arrow indicator Figure 5 In some installations it may be preferred to leave the adhesive paper backing on (older metal ducts or on rough surfaces), and secure the unit with the screws (provided) via the four mounting holes located on the Guardian Air REME TM units mounting plate, refer to Figure 6. Figure 6

Once unit is secured, apply the foil sealing ring to ensure an airtight seal. Remove the paper backing, center over unit, smooth and press firmly over entire surface to ensure a good seal (make sure corresponding sealing surface is clean and dry), refer to Figure 7. Figure 7 3. Electrical Connection: The Guardian Air unit comes standard with 100-240 VAC 50/60 Hz transformer. This transformer comes with an input connection that is a standard 3 prong 120 VAC plug (US). The output wiring terminates with a male 12 VDC jack, which connects directly to the Guardian Air unit. RGF recommends for optimal performance and maximum cell life that the Guardian Air product operate continuously with the fan running. This can be accomplished by either plugging the power supply into the EAC outlet on the air handling unit or plugging the power supply into an external duplex outlet. Mount the transformer with the provided 4 mounting screws near the Guardian Air units as well as a suitable electrical outlet, see Figure 7. Figure 7

Note: The Guardian Air unit comes complete with a standard 120 volt US wall plug. However, the switching power supply shown in Figure 7 is capable of using any input voltage between 100 to 240 volts AC (50/60 Hz). It is highly recommended that when installation requirements dictate using an input voltage other than the standard 120 volt wall plug, that these connections be performed by a licensed, qualified electrician or HVAC contractor. Connect the switching power supply output line (12 VDC) to the Guardian Air unit by inserting the male barrel connector into the DC jack located on the lower side of the Guardian Air housing (6 o clock position). Once fully inserted, twist the connector ¼ turn to lock in place. Plug in the power supply to the 120 volt wall outlet with the provided cord, the installation is now complete. For installations with other voltages requirements, please have your licensed electrician or HVAC installer connect the power and energize the unit. 4. Particle Collector: If your unit came with the optional particle collector, this must be sized by your HVAC contractor to ensure a proper fit into your existing HVAC filter frame holder. Once sized, the installer would connect the green grounding wire to a suitable grounded surface (if already properly grounded, the filter holder frame or the HVAC housing are suitable). This ground bonding is critical to optimize the performance of the collector, and should be determined by the installer. Once installed, the collector will need to be cleaned on a regular basis (determined by the loading levels in your particular environment). It is recommended that the collector be inspected monthly until the proper cleaning interval is determined. To clean the collector, simply disconnect the press together wire terminal for the collector ground, and remove the collector from the frame in the same manner as a standard type HVAC filter. Once removed the collector may be vacuumed with a shop-vac type vacuum, or cleaned with a garden hose (a mild washing detergent solution may also be used). Once cleaned (and if washed, then dried), replace the collector in the same location in your HVAC filter frame, and then reconnect the bonding terminal. Replacing REME TM Cell:

BEFORE CHANGING REME CELL COMPLETELY DISCONNECT FROM POWER Remove unit from duct: Unscrew four mounting screws (if used), cut aluminum sealing ring, and then gently pry away from surface of duct. If mounting adhesive was used, slowly separate mounting plate from duct surface by breaking the adhesive seal with a thin flat object such as a metal putty knife. With the Guardian Air REME TM Assembly removed, remove four (4) Philips screws from back of mounting plate and remove the domed housing (if adhesive sealing ring was used, this will need to be scraped away with a putty knife to reveal screws). Once housing is free from mounting plate, carefully free connector from REME TM Cell.

Firmly grip connector and with a gentle rocking motion remove connector from cell pins. Remove three (3) Phillips screw attaching REME TM Cell to mounting plate. Replace with new REME TM Cell and reassemble unit.

FAQ (Frequently Asked Questions): Q. Is it O.K. to run the unit all the time, or is it better to cycle with the fan? A. The Guardian Air unit treats your home when the HVAC unit fan is on, it is recommended to leave your fan on continually when possible to provide maximum benefit. However, cycling the unit on and off with the fan is acceptable, but be aware that excessive repeated cycling may degrade the useful life of the cell elements, RGF recommends running the unit continuously. Q. Can the unit be installed on the return air side of the HVAC? A. The best location for your Guardian Air unit is in the plenum, just after the air handler. This allows for full distribution and extended air treatment. In situations were it is somehow impossible to locate the unit after the HVAC unit, it is acceptable to locate the Guardian Air unit before the HVAC unit, however the high moisture content of the cooling coils, as well as the high temp of the heating coils will reduce the effective treatment capacity of the unit. Q. If the Blue Indicator lamp is not illuminated, is my REME TM cell not working properly? A. In some instances that may be the case, however, it could also mean that the unit just needs to be reset. To do this, simple unplug the 12 volt power cord from the unit, wait five seconds, and then re-install. Q. After two years my Guardian Air unit indicator light still glows blue, so it is still working right? A. The blue indicator light does in fact let you know if the unit is operating or not. However, it does not indicate the relative output of the unit. The output of the unit reduces with time, and after two years of operation, it is recommended to change out the replaceable REME TM cell insert to maintain optimum effectiveness of the unit.

LIMITED WARRANTY This warranty supersedes and replaces any warranty statements made orally by the Sales Person, Distributor, or Dealer, or contained in the written instructions or other brochures or informational documents related to this product. Manufacturer warrants the new Guardian Air by RGF equipment to be free from defects in material and workmanship under normal use and service when operated and maintained in strict accordance with manufacturer s instructions for a period of twenty four (24) months from the date of receipt of equipment. Manufacturer s obligation under this warranty is limited to repairing or replacing any part found to its satisfaction to be so defective. The manufacturer at its discretion may replace / exchange the defective unit up to 90 days from the date purchase. Hereafter it will need to be returned under a Returned Materials Authorization (RMA) for review and or repair (if found defective). This warranty does not cover parts damaged by decomposition from chemical action or wear caused by abrasive materials, nor does it cover damage resulting from misuse, abuse, or any other than its intended use, accident, neglect, or from improper operation, maintenance, installation, modification or adjustments. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. To obtain warranty service and return authorization number, contact your supplier. Include a copy of your Bill of Sale, Invoice or Receipt of Purchase, with an explanation of the problem or defect. Hg- LAMP CONTAINS MERCURY Manage in accord with disposal laws. See: www.lamprecycle.org

How long is the warranty? LIMITED WARRANTY COMMON QUESTIONS For two (2) years from initial purchase date. How do I contact the Manufacturer about my warranty, a question or complaint? Your local Sales Representative may answer a question or complaint. If they cannot answer the warranty question or complaint, you can contact your local supplier and request the warranty department. Are there any parts not covered by this warranty (that the manufacturer will not repair or replace)? Yes. Parts damaged by decomposition from chemical action, humidity, moisture, or wear caused by abrasive materials. It does not cover damage resulting from misuse, abuse, or any other use other than its intended use. This warranty does not cover accident, neglect, or from improper operation, maintenance, installation, modification or adjustments. Parts not made by Manufacturer. However your supplier will process the claim with the other manufacturer. What do I do in the event the equipment is damaged in shipping? Immediately upon receipt of the unit, you as the purchaser should inspect the unit and test it to make sure it is operational. If there is visible damage to the equipment: 1. Notify the carrier shipping office immediately and write on the Bill of Lading the visible damage or part(s), which are broken or missing. 2. Call your local supplier immediately to specify the damage. 3. Your supplier should refund the unit at the suppliers cost. 4. Your unit will be replaced or repaired as soon as possible.

What if I find damage to the equipment after the carrier leaves? Claims for concealed shipping damage must be reported to the carrier and a copy sent to your supplier in writing via telefax or certified U.S. Mail within fifteen (15) days from the date of delivery. Note: Please take note that the carrier will not cover the damages if these steps are not adhered to. Steps to take when you have determined that your equipment is malfunctioning within the warranty period. Call your distributor and notify them of the problem or malfunction. If it is determined that a part is malfunctioning due to a defect, ship unit to your supplier or call supplier for other means of return. The Equipment Warranty Form should be completed and included. Your supplier will repair or exchange the defective unit with a working replacement. Things I should do to avoid problems or injuries when running my GUARDIAN AIR Equipment. Thoroughly read and understand all Operating Instructions, Warnings and Precautions before commencing application. What service can I expect from my distributor? Your distributor will assist you with any problems or questions you may have. Sell you optional parts or equipment as needed. Assist you with any warranty problems and provide you with a Warranty Request Form (which is required when sending a warranty unit back to the manufacturer for repair or replacement).

Other RGF Advanced Oxidation Products The Guardian Air Plug In Natural Air Purification System provides bacteria, mold, odor and VOCs (chemical odors) reduction. The advantage of the Guardian Air Plug In is its ability to be used in any room and be completely inconspicuous. The Guardian Air Plug In plugs directly into a wall outlet and can be used with or without its internal fan. Because it has its own outlets as part of the unit, you do not lose the wall outlet. The Guardian Air Plug In is an air treatment system not a filter. The RGF - IMSB is designed for use on ice machine small compactors and holding tanks. The unit utilizes the PHI Cell to create hydroperoxides, super oxide ions, and hydroxides. The additional oxidizers provide a broader range of applications and redundant oxidation gases. The Guardian Air by RGF is designed to eliminate sick building syndrome risks by reducing odors, air pollutants, VOCs (chemical odors), smoke, mold, bacteria and viruses*. The HVAC-PHI Cells are easily mounted into air conditioning and heating systems air ducts where most sick building problems start. When the HVAC system is in operation the HVAC-PHI Cell creates an Advanced Oxidation Process consisting of: Hydro-peroxides, super oxide ions and hydroxide ions. All are friendly oxidizers. By friendly oxidizers we mean oxidizers that revert back to oxygen and hydrogen after the oxidation of the pollutant. The Mini PHI Cell by RGF features the same technology as the Guardian Air but is designed to fit into smaller HVAC systems such as PTACS Fan coils and unit ventilators. Turbozone is designed to provide ozone and advanced oxidation gases for commercial air purification and odor destruction. This unit is fully automatic, easy to use. The Turbozone destroys odor molecules and leaves no residue. This product has been engineered, designed, built, tested and thousands retailed. The Turbozone will destroy, not just cover up, the following airborne substances: smoke, mold, bacteria, viruses, VOCs, pollen and many more. Housed in a light weight heavy duty stainless steel case the 1000 is designed for small to medium commercial jobs. Not to be used in occupied spaces.

WARRANTY REQUEST FORM RETURN AUTHORIZATION NO. CUSTOMER: NAME ADDRESS CITY STATE ZIPCODE CONTACT PHONE FAX DISTRIBUTOR: NAME ADDRESS CITY STATE ZIPCODE CONTACT PHONE FAX UNIT: MODEL # SERIAL # INVOICE # DATE OF PURCHASE ITEM(S) SUBMITTED FOR WARRANTY: 1) 2) REASON(S) FOR RETURN: (FOR MANUFACTURER USE ONLY) DATE ITEM(S) RECEIVED: RECEIVED BY: REPLACEMENT UNIT OR PART SENT COMMENTS: NOTE: THIS COMPLETED FORM MUST ACCOMPANY ALL RETURNED ITEMS. SHIP TO YOUR DISTRIBUTOR OR SUPPLIER IN YOUR REGION Fax: (561) 848-1160