TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Similar documents
SECTION Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters)

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

NAVIEN AMERICA INC FITCH AVENUE

THERM Tankless Water Heaters. Applications Manual

SOLI TANKLESS PRODUCT GUIDE

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Navien Condensing 98% Tankless Water Heaters. Tankless Water Heaters. Navien Condensing. The Ultimate in Energy Efficiency with Hi-Tech Comfort

HEAVY DUTY STORAGE GAS

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

Commercial Gas Water Heater

Applications manual. For tankless and point-of-use water heaters

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

CHAPTER 9: WATER HEATING

RECON WATER HEATER INSTALLATION FORM

Domestic Hot Water Systems and Plumbing Products

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

TANKLESS DURABILITY Tankless Product Guide

Installation & Operation Manual Models: SIT030 - SIT119

Commercial Gas Water Heaters

Tankless water heaters

What you can expect from your Solar Hot Water System

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

On-Demand Water Heater System Design Manual

Commercial Gas Water Heaters

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

Tankless Water Heater A Primer for Contractors, Installers, Builders and Homeowners

Applications manual. For tankless and point-of-use water heaters

Indirect Fired Water Heaters

Case Studies in Restaurant Water Heating

T-K3 Instantaneous Water Heater Installation Manual and Owner s Guide

Mega-Stor INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

T-KJr. Instantaneous Water Heater Installation Manual and Owner s Guide

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Codes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC

Commercial Boiler Systems and Controls

E-gas Instant Gas Water Heaters

Saving Water and Energy in Residential Hot Water Distribution Systems. Gary Klein California Energy Commission

FYI > California Title 24

Techtanium Solar Indirect Water Heater Instruction Manual

Session 2: Hot Water Supply

Element D Services Plumbing

2010 Residential Water Heater Replacement Check List

WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Tankless Gas Water Heaters Second Generation Indoor, Outdoor and Direct Vent Up to 199,000 BTU

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50/16LP50, 16NG60/16LP60, 20NG50/20LP50, 20NG60/20LP60, 26NG50/26LP50, 26NG60/26LP60

Electric Water Heater

In the average American home, water heating accounts

California Solar Initiative (CSI) Thermal Program Metering Installation Guide

Better Boilers.

Eternal Hybrid: Engineered For How You Live. Award Winning Technology. Now Available in Canada.

Measure Guideline: Transitioning to a Tankless Water Heater

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

GREENTHERM & THERM Tankless Water Heaters

WATER HEATER SIZING GUIDELINES FOR INITIAL INSTALLATION & REPLACEMENT

FOOD ESTABLISHMENT GUIDE FOR DESIGN, INSTALLATION, AND CONSTRUCTION RECOMMENDATIONS

PLUMBING SUBMITTAL

Electric & Gas Water Heaters


GOLD Plus 30/40/60/80

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

Hot Water System Design Manual

WARRANTY BOOKLET. Commercial Water Heaters. Register online at

SIOUX HYBRID WATER HEATER

NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS

SPIDERfire: Delivers high efficiency and real savings for today s businesses

Electric Flow Boiler

Guide for Efficient Hot Water Delivery Systems

Installation & Operation Manual Models: STU

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

T-K2 Instantaneous Water Heater Installation Manual and Owner s Guide

SERVICE INSTRUCTIONS

Operators manual Basic water heater

Plumbing Identification and Damage Assessment Guide

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Installation Operation Maintenance

What to Expect From the Examination. How to Study the Plumbing Codes

Cost Estimation for Materials and Installation of Hot Water Piping Insulation

Installation and Operating Instruction Manual

Water Heaters. Condensing Storage. In my 30-plus years as a plumbing contractor,

AMX300 DirectConnect Mixing Valve Kits

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

Owner s Guide and Installation Instructions

INSTANT HOT WATER RECIRCULATING SYSTEM

WATER HEATERS. If your water heater tank is leaking, then your course is clear: buy a new unit. But if it isn t, your answer is less obvious.

DIVERSIFIED HEAT TRANSFER, INC Flushing Avenue Ridgewood, NY Phone: / Fax:

Indirect-fired Steam & Boiler Water Heaters

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

Commercial Gas Water Heaters

Baxi Combi 80e & 105e

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Builder Specifications for Solar Ready Homes

TANKLESS GAS WATER HEATER

Transcription:

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water heater that will serve to maintain the temperature of the recirculation loop. The recirculation loop shall be returned to the cold water inlet of the small tank-type water heater. It is recommended that the circulation pump be placed on a timer or controlled by an immersion thermostat. Shut-off Check Return Line Printed in U.S.A 01/09 Form No. RTG11140A

Installation Diagrams EZ-Link Manifold Installation / Optional Return EZ-Link Cable Small 10-15 Gallon Point-of-Use Water EZ-Link Manifold Installation and Optional Return : Two tankless water heaters of like models shall be installed in a parallel manifold, connected with the EZ-Link cable. Only one remote control will be used connected to a single tankless water heater. These units will feed a single, small capacity water heater that will serve to maintain the temperature of the recirculation loop. The recirculation loop shall be returned to the cold water inlet of the small tank-type water heater. It is recommended that the circulation pump be placed on a timer or controlled by an immersion thermostat. Shut-off Check Return Line Printed in U.S.A 01/09 Form No. RTG11141

Installation Diagrams EZ-Link Manifold Installation / Optional Return F Hot Water to Fixtures RECIRCULATION OPTION A Dedicated Return Immersion Aquastat EZ-Link Cable Gas Supply Timer RECIRCULATION OPTION B Dedicated Return Immersion Aquastat Timer Expansion Tank Supply Small 10-15 Gallon Point-of-Use Water EZ-Link Manifold Installation and Optional Return : Two tankless water heaters of like models shall be installed in a parallel manifold, connected with the EZ-Link cable. Only one remote control will be used connected to a single tankless water heater. Recirculation Option A: The recirculation loop shall be returned to the cold water inlet of the small tank-type water heater with the hot water outlet connected to the hot water line feeding the fixtures. The tank temperature and aquastat should be set 5 F below the tankless thermostat setting, the timer set for peak demand periods. The pump shall be sized according to the loop head loss. Recirculation Option B: The recirculation loop shall be returned to the cold water manifold feeding the tankless. It is required that the circulation pump be placed on a timer and controlled by an immersion thermostat. The aquastat shall be set 10 F below the thermostat setting of the tankless, the timer shall be set for peak demand periods. The pump shall be sized for 5 GPM @ 25 of head plus the loop head loss. Shut-off Check Return Line Printed in U.S.A. 01/11 Form No. RTG11141 Rev 2

Installation Diagrams Heavy Duty Tankless Manifold Equipment Schedule Tankless Units Manifolded MIC-180 ler MICS-180 ler MIC-K* Cable AP12993C Relief AP13892 Isolation Kits Maximum System Flow Rate (gpm) Min. Hot Water Header Size (in.) ** Min. Header Size (in.) ** System Total Gas Input (btuh) Min. Natural Gas Header Size (in.) *** Min. LP Gas Header Size (in.) **** 2 1 0 2 2 2 14.8 1 1 399,800 1 ¾ 3 1 0 3 3 3 22.2 1 1 599,700 1 ¼ 1 4 1 0 4 4 4 29.6 1 ¼ 1 ¼ 799,600 1 ¼ 1 5 1 0 5 5 5 37 1 ½ 1 ½ 999,500 1 ¼ 1 6 1 0 6 6 6 44.4 1 ½ 1 ½ 1,199,400 1 ½ 1 ¼ 7 1 1 7 7 7 51.8 2 2 1,399,300 1 ½ 1 ¼ 8 1 1 8 8 8 59.2 2 2 1,599,200 2 1 ¼ 9 1 1 9 9 9 66.6 2 2 1,799,100 2 1 ½ 10 1 1 10 10 10 74 2 2 1,999,000 2 1 ½ 11 1 1 11 11 11 81.4 2 2 2,198,900 2 ½ 1 ½ 12 1 1 12 12 12 88.8 2 2 2,398,800 2 ½ 1 ½ 13 1 1 13 13 13 96.2 2 ½ 2 ½ 2,598,700 2 ½ 2 14 1 1 14 14 14 103.6 2 ½ 2 ½ 2,798,600 2 ½ 2 15 1 1 15 15 15 111 2 ½ 2 ½ 2,998,500 2 ½ 2 16 1 1 16 16 16 118.4 2 ½ 2 ½ 3,198,400 3 2 17 1 1 17 17 17 125.8 3 3 3,398,300 3 2 18 1 1 18 18 18 133.2 3 3 3,598,200 3 2 19 1 1 19 19 19 140.6 3 3 3,798,100 3 3 20 1 1 20 20 20 148 3 3 3,998,000 3 3 OPTIONAL EQUIPMENT AND ACCESSORIES MIC-180 Multiple Unit ler - controls up to 6 units MICS-180 Multiple Unit Extender - add on to the MIC-180 for control of up to 20 units MIC-K Cables Multiple Unit Cables, available in 16-, 32-, and 65-foot lengths AP12993C - 150 PSI AP13892 Isolation Kit - includes shut-off valves * ** *** **** MIC-K cable length to be selected based upon water heater layout. ow ball valves should be used as a standard Smooth copper pipe sizes Black iron pipe sizes (nominal 7 in. w.c. pressure) Black iron pipe sizes (nominal 11 in. w.c. pressure) Printed in U.S.A 07/07 Form No. RTG11145

Installation Diagrams Multiple Unit Manifold Installation Manifold ler Communication Cables Multiple Unit Manifold Installation: Multiple tankless water heaters of like models shall be installed in a parallel manifold, connected with a common manifold control through communication cables, with only one remote control connected to the manifold controller. The units will operate in a random sequence depending upon the water flow rate through the system. The manifold controller will manage the operation of the system. Each tankless water heater shall be installed using code-approved isolation valves and unions to allow service to an individual tankless water heater without taking the entire system offline. Piping or the plumbing manifold should be properly sized for the number of tankless water heaters being installed. See the Manifold Equipment Schedule, Form No. RTG11145, for details on pipe size and suggested equipment. Shut-off Check Return Line Printed in U.S.A 01/09 Form No. RTG11142

Installation Diagrams Multiple Unit Manifold Installation with Direct Recirculation Manifold ler Communication Cables Multiple Unit Manifold Installation with Direct Recirculation: Multiple tankless water heaters of like models shall be installed in a parallel manifold, connected with a common manifold control through communication cables, with only one remote control connected to the manifold controller. The units will operate in a random sequence depending upon the water flow rate through the system. The manifold controller will manage the operation of the system. Each tankless water heater shall be installed using code-approved isolation valves and unions to allow service to an individual tankless water heater without taking the entire system offline. Piping or the plumbing manifold should be properly sized for the number of tankless water heaters being installed. See the Manifold Equipment Schedule, Form No. RTG11145, for details on pipe size and suggested equipment. The return circulation line shall be connected back to the cold water manifold, and include a check valve and a circulation pump that is on a timer and/or an immersion thermostat control. The pump must be sized properly for the system and head loss through the tankless water heater, atleast 5 GPM at 25 foot of head. Also, an expansion tank must be installed on the system. Shut-off Check Return Line Printed in U.S.A 01/09 Form No. RTG11143

Installation Diagrams Multiple Unit Manifold Installation with Alternate Indirect Recirculation Hot Water Supply Manifold ler Expansion Tank Return Immersion Aquastat Communication Cables Gas Small 10-15 Gallon Point-of-Use Water or Storage Tank Multiple Unit Manifold Installation with Alternate Indirect Recirculation Multiple tankless water heaters of like models shall be installed in a parallel manifold, connected with a common manifold control through communication cables, with only one remote control connected to the manifold controller. The units will operate in a random sequence depending upon the water flow rate through the system. Each tankless water heater shall be installed using code-approved isolation valves and unions to allow service to an individual tankless water heater without taking the entire system offline. Piping or the plumbing manifold should be properly sized for the number of tankless water heaters being installed. See the Manifold Equipment Schedule, Form No. RTG11145, for details on pipe size and suggested equipment. The hot water main return circulation shale be installed according to code and shall circulate through a small storage vessel or point of use water heater that is not connect to electricity. The tankless water heaters shall maintain the temperature of the storage vessel through a secondary circulation loop with a thermostatically controlled pump. The secondary circulation system shall be plumbed so that hot water from the tankless does not return directly to the tankless inlet until it has passed through the storage vessel and so that the hot water main return does not directly recirculate through the tankless water heaters. An immersion aquastat shall control the operation of the secondary circulation pump so that when the temperature of the storage vessel is reached it will turn off the pump. It is recommended that the hot water main circulation line also be controlled by an aquastat and or timer. Shut-off Check Return Line Printed in U.S.A 01/09 Form No. RTG11144

Installation Diagrams Multiple Unit Manifold Installation with Dual Temperature Recirculation 140 F Water Supply Thermostatic Tempering 110 F Water Supply Manifold ler Expansion Tank 110 F Return Communication Cables 140 F Return Small 10-15 Gallon Point-of-Use Water Thermostat set to 110 F Multiple Unit Manifold Installation with Dual Temperature Recirculation Multiple tankless water heaters of like models shall be installed in a parallel manifold, connected with a common manifold control through communication cables, with only one remote control connected to the manifold controller. The units will operate in a random sequence depending upon the water flow rate through the system. Each tankless water heater shall be installed using code-approved isolation valves and unions to allow service to an individual tankless water heater without taking the entire system offline. Piping or the plumbing manifold should be properly sized for the number of tankless water heaters being installed. See the Manifold Equipment Schedule, Form No. RTG11145, for details on pipe size and suggested equipment. The high temperature return circulation line shall be connected back to the main cold water manifold, and include a check valve and a circulation pump that is on a timer and/or an immersion thermostat control. The pump must be sized properly for the system and head loss through the tankless water heaters. The low/second temperature return circulation line will be connected back to a small point-of-use tank-type water heater, with a circulation pump controlled by a timer and/or an immersion thermostat control. The tank-type heater will maintain the temperature of the second recirculation loop. Two expansion tanks must be installed, one on each recirculation system. Shut-off Check Return Line Printed in U.S.A 01/09 Form No. RTG11146

Installation Diagrams Dual Temperature Recirculation Expansion Tank 140 F Water Supply Thermostatic Tempering 110 F Water Supply 110 F Return 140 F Return Small 10-15 Gallon Point-of-Use Water Thermostat set to 110 F Single Unit Installation with Dual Temperature Recirculation A single tankless water heater shall be installed using codeapproved isolation valves and unions to allow service. Piping or the plumbing manifold should be properly sized for the tankless water heater being installed. The high temperature return circulation line shall be connected back to the main cold water manifold, and include a check valve and a circulation pump that is on a timer and/or an immersion thermostat control. The pump must be sized properly for the system and head loss through the tankless water heaters. The low/second temperature return circulation line will be connected back to a small point-of-use tank-type water heater, with a circulation pump controlled by a timer and/or an immersion thermostat control. The tank-type heater will maintain the temperature of the second recirculation loop. Two expansion tanks must be installed, one on each recirculation system. Shut-off Check Return Line Printed in U.S.A 01/09 Form No. RTG11147

Installation Diagrams Dual Temperature Recirculation 120 F Water Supply Expansion Tank 180 F Water Supply Thermostatic Tempering 180 F Return Small 10 Gallon Booster Water Thermostat set to 180 F 120 F Return Single Unit Installation with Dual Temperature Recirculation A single tankless water heater shall be installed using code-approved isolation valves and unions to allow service. Piping or the plumbing manifold should be properly sized for the tankless water heater being installed. The high temperature return circulation line shall be connected back to the cold water input of the Booser, and include a check valve and a circulation pump that is on a timer and/or an immersion thermostat control. The pump must be sized properly for the system and head loss through the tankless water heaters. The low/second temperature return circulation line will be connected back to the cold water main at the tankless water heater, with a circulation pump controlled by a timer and/or an immersion thermostat control. The booser heater will maintain the temperature of the second recirculation loop. Two expansion tanks must be installed, one on each recirculation system. Shut-off Check Return Line Printed in U.S.A 01/09 Form No. RTG11148

Installation Diagrams EZ-Link Manifold Installation / Optional Return F Hot Water to Fixtures RECIRCULATION OPTION A Dedicated Return Immersion Aquastat EZ-Link Cable Gas Supply Timer RECIRCULATION OPTION B Dedicated Return Immersion Aquastat Timer Expansion Tank Supply Small 10-15 Gallon Point-of-Use Water EZ-Link Manifold Installation and Optional Return : Two tankless water heaters of like models shall be installed in a parallel manifold, connected with the EZ-Link cable. Only one remote control will be used connected to a single tankless water heater. Recirculation Option A: The recirculation loop shall be returned to the cold water inlet of the small tank-type water heater with the hot water outlet connected to the hot water line feeding the fixtures. The tank temperature and aquastat should be set 5 F below the tankless thermostat setting, the timer set for peak demand periods. The pump shall be sized according to the loop head loss. Recirculation Option B: The recirculation loop shall be returned to the cold water manifold feeding the tankless. It is required that the circulation pump be placed on a timer and controlled by an immersion thermostat. The aquastat shall be set 10 F below the thermostat setting of the tankless, the timer shall be set for peak demand periods. The pump shall be sized for 5 GPM @ 25 of head plus the loop head loss. Shut-off Check Return Line Printed in U.S.A. 01/11 Form No. RTG11141 Rev 2

Installation Diagrams Tankless Installation With Air Handler and Domestic Water Room Thermostat 120 F Domestic Water Supply Thermostatic Tempering Air Handler 30,000 to 60,000 Btu/hr with 140 F Water Priority Switch Single with Domestic Water and Home Heating: One tankless water heater installed in a dual use system with domestic water and an air handler for home heating. The system will supply a maximum of 140 F water to the air handler. A thermostatic tempering valve will provide control for the 120 F domestic water temperature. The heating system will be controlled by a room thermostat or environmental control system. There will be a priority switch (flow detector) installed in the cold water source line. The priority switch will deactivate the circulation pump and air handler while water is being drawn from the cold water supply, such as for showering. The priority switch will reactivate the circulation pump and air handler when the domestic water supply is not in use. The circulation pump must be able to supply a minimum of 5 GPM at 35 of head loss and shall be controlled by the room thermostat or environmental control system. An expansion tank shall be installed on the system to control thermal expansion when the air handle is in use. The air handler, circulation pump, and tankless water heater should be sized by a professional contractor or mechanical engineer to ensure proper operation. Shut-off Check Return Line Printed in U.S.A 10/07 Form No. RTG11149

Installation Diagrams Multiple Unit Manifold Installation with Buffer Storage Tank Manifold ler Hot Water Supply Communication Cables Gas Hot Water To Fixtures FIxture Return Line Immersion Aquastat Shut-off Check Multiple Unit Manifold Installation with Buffer Storage Recirculation Multiple tankless water heaters of like models shall be installed in a parallel manifold, connected with a common manifold control through communication cables, with only one remote control connected to the manifold controller. The units will operate in a random sequence depending upon the water flow rate through the system. Piping or the plumbing manifold should be properly sized for the number of tankless water heaters being installed. See the Manifold Equipment Schedule, Form No. RTG11145, for details on pipe size and suggested equipment. The storage vessel will be fed direct from the tankless and act as a buffer between the fixtures and tankless. A Taco 0011 pump or greater shall be used to circulate the water from the storage vessel back to the tankless units and an immersion thermostat in the storage vessel will control the circulation pump so that the tankless are used only when the temperature of the tank drops. The tankless will also operate when a demand is placed on the system such as a hot water use fixture is turned on. A return circulation line from the fixtures will be feed back to the storage tank with an appropriately sized circulation pump, placed on a timer to limit the hours of operation. Return Line Printed in U.S.A 01/09 Form No. RTG11150

Installation Diagrams Multiple Unit Manifold Installation with Direct Return PRIORITY Manifold ler Communication Cables Hot Water Supply Gas FIxture Return Line Immersion Aquastat Hot Water To Fixtures Multiple Unit Manifold Installation with Direct Return Recirculation Multiple tankless water heaters of like models shall be installed in a parallel manifold, connected with a common manifold control through communication cables, with only one remote control connected to the manifold controller. The units will operate in a random sequence depending upon the water flow rate through the system. Piping or the plumbing manifold should be properly sized for the number of tankless water heaters being installed. See the Manifold Equipment Schedule, Form No. RTG11145, for details on pipe size and suggested equipment. A Taco 0011 pump or greater shall be used to circulate the water from the return recirculation line back to the tankless units and an immersion thermostat in recirculation line will control the circulation pump so that the tankless are used only when the temperature of the loop temperature drops. The tankless will also operate when a demand is placed on the system such as a hot water use fixture is turned on. Mixing (Optional) Shut-off Check Return Line Printed in U.S.A 02/10 Form No. RTG11151 F

Installation Diagrams Multiple Unit Manifold Installation Stacked Configuration Manifold ler Communication Cables Hot Water Supply Gas Return Line Check Shut-off Return Line Printed in U.S.A 03/08 Form No. PII030706

Installation Diagrams Tankless Installation / Demand Return Kitchen or Sink Faucet Room Motion Sensor or Trigger Switch Check with the Manufacture for options Shower or Bath Lavatory or Sink Faucet Metlund S-70T or S-02T D MAND System or equivalent Expansion Tank Single and Demand Return : A demand return circulation system is one that the pump is controlled by system as to where the pump is only operated for a short duration to bring hot water to the desired fixture. A demand system operates with either a push button or motion detector and shut off as soon as hot water reaches the fixture. A circulation pump with a timer and/or aquastat is not considered a demand pump as they can continuously run. The Metlund D MAND System is an alternative to a hot water circulation loop and operates in a manner that only runs when hot water is needed at the fixture. A demand system of this type does not impact the warranty of our tankless water heaters. This drawing demonstrates a basic installation of a demand system with a tankless water heater. Follow the manufactures recommended installation instructions and guidelines. Shut-off Check Return Line This drawing is intended as a guide only. It is not to be used as an alternative to Printed in U.S.A. 06/08 Form No. RTG11154

Installation Diagrams Multiple Unit Manifold Installation with Buffer Tank and Demand Recirculation Kitchen or Sink Faucet Manifold ler Room Motion Sensor, Push Button Trigger Switch, or Timer Metlund S-70T or S-02T D MAND System or Laing ACT-909 System Communication Cables Gas Small 10-15 Gallon Point-of-Use Water With Openings Large Enough to Accommodate Manifold Pipe Size Multiple Unit Manifold Installation with Buffer Tank and Demand Recirculation Multiple tankless water heaters of like models shall be installed in a parallel manifold, connected with a common manifold control through communication cables, with only one remote control connected to the manifold controller. The units will operate in a random sequence depending upon the water flow rate through the system. Each tankless water heater shall be installed using code-approved isolation valves and unions to allow service to an individual tankless water heater without taking the entire system offline. Piping or the plumbing manifold should be properly sized for the number of tankless water heaters being installed. See the Manifold Equipment Schedule, Form No. RTG11145, for details on pipe size and suggested equipment. The hot water main shall be installed according to code and shall pass through a small water heater or storage tank that will be used as a buffer tank to eliminate the cold water sandwich effect from short cycle usage. The buffer tank shall have openings sized to match the manifold pipe size. The main hot water line will feed branch fixtures after the buffer tank. A demand or thermostatically controlled circulation pump, such as the Metlund S-70T or S-02T, or the Laing ACT-909, shall be installed on each branch at the furthermost fixture. These pumps will operate to draw hot water to the fixture by pushing the cold water back through the cold water supply line. When the hot water reaches a given temperature as set by the pump manufacture, the pump will shut off. This application is ideal in salons, public rest rooms, and nursing homes where the draw demands on hot water are short and spaced apart. Shut-off Check Return Line Printed in U.S.A 03/09 Form No. RTG11155

Installation Diagrams Tankless Installation as Solar Booster F Domestic Hot Water Supply Solar Panels Water Supply to Tankless Solar Storage Tank Thermostatic Tempering * Solar Fluid Domestic Supply NOTE: A temperating valve must be installed on the hot water outlet from the solar tank feeding the inlet to the tankless water heater. Single as a Solar Booster : A tankless unit will be connected inline with the hot water output of a solar storage tank and the hot water supply to the fixtures. The supply to the tankless must be connected to a thermostatic mixing valve so that the tankless does not receive water exceeding 140F. The tankless unit(s) should be sized according to the total demand of the application. When the water temperature drops below the T-stat setting on the tankless and the flow is great enough, the tankless unit will engage. Refer to the tankless Use and Care manual for installation instructions and recommendations for the tankless water heater. Shut-off Check Return Line Printed in U.S.A 06/10 Form No. RTG11160 Rev 2

Installation Diagrams RTG20147 Concentric Direct Vent Kit - Typical Installation 94 Degree Elbow Wall Plate 12 Vent Pipe Appliance Adapter Wall Plate Horizontal Termination The RTG20147 Kit Contains: (1) 3/5" Appliance Adapter - RTG20144 (1) 3/5" Horizontal Termination - RTG20128 (1) 94 Degree 3/5" Elbow - No Rheem Part Number (2) 12" Wall Plate, Screws - No Rheem Part Number (1) 3/5" Concentric 12" Vent Pipe - RTG20151R (1) Relief - AP12993C (1) 10ft T-Stat Wire - RTG20009-1 See Drawing RTG11140 for typical piping installations. Printed in U.S.A 01/09 Form No. RTG11175

Specification RTG-95 Series Tankless Engineering Specification RTG-95DV Direct Vent Water Water (s) shall be internally mounted, instantaneous, multiple point-of-use, gas fired, direct vent, water heater(s) design certified to the ANSI Z21.10.3 standard for gas-fired water heaters. (Each) Water shall produce no more than 55 ppm NOx (40 ng/j) emissions when tested in accordance with the Rules and Regulations of the South Coast Air Quality Management District (SCAQMD). Said water heater(s) shall be configured to operate with (natural/propane) gas and a 120 volt/60 Hz AC power source. Unit(s) shall have a BTU input range of11,000 BTU/ hr to 199,900 BTU/hr, a minimum recovery efficiency rating of 82%, a minimum hot water outlet capacity of 9.5 gallon per minute (with a 35 F temperature rise), and a minimum operating flow rate of 0.26 (0.40 activation) gallon per minute (with a 35 F temperature rise). Water (s) shall be microprocessor controlled and utilize a direct electronic ignition system (with no standing pilot), fully modulating gas control valve, turbine water flow meter, automatic electro-mechanical water flow control valve, and water temperature thermistors to maintain outlet water temperature between ± 2 F of setpoint temperature. Unit(s) shall incorporate the following internal safety devices: incomplete combustion sensing burner technology, film-type thermal overheat protection covering entire heat exchanger, flame failure lockout, internal freeze protection for ambient temperatures as low as 30 F, and lockout protection in the event of a blocked flue. Water (s) shall be provided with a remote temperature thermostat with an adjustable setpoint range of 85 F to 140 F. Unit(s) shall also be capable of storing and displaying up to 8 diagnostic maintenance codes, via the display on the remote temperature thermostat controller(s). Water (s) shall have a copper heat exchanger warranted against material defects or workmanship for a period of 12 years from the date of purchase, or 3 years from date of purchase when used as a circulating water heater within a hot water circulation loop or when used in a commercial application. Unit(s) shall have stainless steel burners, cast aluminum gas control valve/ gas connection, and solid brass inlet and outlet water connections. Unit(s) shall also be provided with a 120 volt/60 Hz AC power cord. These and all other parts shall be warranted against material defects or workmanship for a period of 5 years from the date of purchase, or 3 year from date of purchase when used as a circulating water heater within a hot water circulation loop or when used in a commercial application. Water (s) shall be suitable for use in multiple unit electronic manifold installations. Units shall have the ability to be manifolded electronically in configurations from 2-20 units. Temperature control and diagnostic functions for all water heaters in manifold installations shall be controlled via a single remote temperature thermostat. Manifold installations utilizing 2 water heaters shall be accomplished with simple cable-only interconnection (EZ-Link). Manifold installations utilizing up-to water heaters shall utilize an internal electronic manifold controller (MIC-6) which, or up-to 20 units with an external manifold controller system (MIC-185/MICS-180). RTG-95X Outdoor Water Water (s) shall be externally mounted, instantaneous, multiple point-of-use, gas fired, direct vent, water heater(s) design certified to the ANSI Z21.10.3 standard for gas-fired water heaters. (Each) Water shall produce no more than 55 ppm NOx (40 ng/j) emissions when tested in accordance with the Rules and Regulations of the South Coast Air Quality Management District (SCAQMD). Said water heater(s) shall be configured to operate with (natural/propane) gas and a 120 volt/60 Hz AC power source. Unit(s) shall have a BTU input range of 11,000 BTU/hr to 199,900 BTU/hr, a minimum recovery efficiency rating of 82%, a minimum hot water outlet capacity of 9.5 gallon per minute (with a 35 F temperature rise), and a minimum operating flow rate of 0.26 (0.40 activation) gallon per minute (with a 35 F temperature rise). Water (s) shall be microprocessor controlled and utilize a direct electronic ignition system (with no standing pilot), fully modulating gas control valve, turbine water flow meter, automatic electro-mechanical water flow control valve, and water temperature thermistors to maintain outlet water temperature between ± 2 F of setpoint temperature. Unit(s) shall incorporate the following internal safety devices: filmtype thermal overheat protection covering entire heat exchanger, flame failure lockout, and internal freeze protection for ambient temperatures as low as 30 F. Water (s) shall be provided with a remote temperature thermostat with an adjustable setpoint range of 85 F to 140 F. Unit(s) shall also be capable of storing and displaying up to 8 diagnostic maintenance codes, via the display on the remote temperature thermostat controller(s). Water (s) shall have a copper heat exchanger warranted against material defects or workmanship for a period of 12 years from the date of purchase, or 3 year from date of purchase when used as a circulating water heater within a hot water circulation loop or when used in a commercial application. Unit(s) shall have stainless steel burners, cast aluminum gas control valve/gas connection, and solid brass inlet and outlet water connections. These and all other parts shall be warranted against material defects or workmanship for a period of 5 years from the date of purchase, or 3 year from date of purchase when used as a circulating water heater within a hot water circulation loop or when used in a commercial application. Water (s) shall be suitable for use in multiple unit electronic manifold installations. Units shall have the ability to be manifolded electronically in configurations from 2-20 units. Temperature control and diagnostic functions for all water heaters in manifold installations shall be controlled via a single remote temperature thermostat. Manifold installations utilizing 2 water heaters shall be accomplished with simple cable-only interconnection (EZ-Link). Manifold installations utilizing 2 water heaters shall be accomplished with simple cable-only interconnection (EZ-Link). Manifold installations utilizing upto water heaters shall utilize an internal electronic manifold controller (MIC-6) which, or up-to 20 units with an external manifold controller system (MIC- 185/MICS-180). RTG-95 Commercial Installation Water (s) shall be convertible to operate at higher temperature rating for a commercial application. A conversion kit; containing a program chip, commercial warranty, conversion decal, and instructions, for each specific mode is available. This program chip will upgrade the programming in the water heater(s) to allow an adjustable temperature setpoint range from 85 F to 185 F. Water (s) used in a commercial installation with a commercial conversion kit installed shall have a copper heat exchanger warranted against material defects or workmanship for a period of 5 years from the date of purchase, or 3 year from date of purchase when used as a circulating water heater within a hot water circulation loop. Unit(s) shall have stainless steel burners, cast aluminum gas control valve/gas connection, and solid brass inlet and outlet water connections. These and all other parts shall be warranted against material defects or workmanship for a period of 5 years from the date of purchase, or 3 year from date of purchase when used as a circulating water heater within a hot water circulation loop. While the RTG-95 model carries and NSF 5 Rating it cannot be used as a booster to supply a commercial dishwasher or other equipment requiring 180F water for sanitation. A NSF approved booster should be used for those applications. Printed in U.S.A 07/10 Form No. RTG11166