ATLAS RESISTANCE Pier Foundation Systems

Similar documents
New construction Repairing failed or old foundations Retrofit foundations Permanent battered piers Machinery/equipment foundations

A Solid Foundation Solution for Homeowners. from. Our products are made with 90% Recycled Material Down. Right. Solid. GREEN.

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

Designed and Engineered to Perform

The Stabilizer TM. Benefits. Supplemental support system for sagging beams and floor joists within a crawl space

Stability. Security. Integrity.

Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. The Leading Edge.

Now That s IDEAL. Now That s IDEAL. LISTEN. RESEARCH. DESIGN. DELIVER.

SECTION 1 GENERAL REQUIREMENTS

High Capacity Helical Piles Limited Access Projects

PRODUCT DRAWINGS AND RATINGS Section 7

TYPES OF PIERS USED IN NORTH AND EAST TEXAS RESIDENTIAL FOUNDATION REPAIR

System. Stability. Security. Integrity. 150 Helical Anchor

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: HUBBELL POWER SYSTEMS, INC.

Page B-1 Hubbell Power Systems, Inc. All Rights Reserved Copyright 2014 LOAD TESTS

Transmission Foundations. helical piles and guy anchors for transmission structures.

E ER TITAN PRODUCTS. Foundation Repair

High Strain Dynamic Load Testing of Drilled Shafts

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

CITY OF LOS ANGELES CALIFORNIA

symptoms of a faulty foundation

Residential Deck Safety, Construction, and Repair

Transmission Foundations Case History : Helical piles Hydro One Networks Inc.

ENGINEERED FOUNDATIONS. Department of Public Works Jeff Hill, PE

RAM JACK INTRODUCTION

Pro-Lift Steel Pile Foundation Repair

Step 11 Static Load Testing

load on the soil. For this article s examples, load bearing values given by the following table will be assumed.

Chapter 3 Pre-Installation, Foundations and Piers

World Leader in earth anchoring since for Residential and Commercial Construction and Repairs

Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations

How to Design Helical Piles per the 2009 International Building Code

Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation

Wastewater Capital Projects Management Standard Construction Specification

Figure A-1. Figure A-2. continued on next page... HPM-1. Grout Reservoir. Neat Cement Grout (Very Flowable) Extension Displacement Plate

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

Baton Rouge Foundation Repair

BUTE Department of Construction Management and Technology

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Sliding Barn Door Hardware Installation Instructions BALDUR and ODEN

Helical Foundation Systems

POST FOUNDATION REPAIR PERFORMANCE RESIDENTIAL AND OTHER LOW-RISE BUILDINGS ON EXPANSIVE SOILS. The Repair Committee of

Underpinning Systems 14.1 FOUNDATION REPAIR. Helical Piles

Structural Foundation System

Lighthouse Engineering, L.L.C.

EXAMPLE 1 DESIGN OF CANTILEVERED WALL, GRANULAR SOIL

PART E SPECIFICATIONS

Sliding Door Hardware Installation Instructions

USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

The International Workshop on Micropiles, 2007

Guidelines for Earthquake Bracing of Residential Water Heaters

PILE FOUNDATIONS FM 5-134

Operations and Instruction Manual Might Swivel - Part # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn

SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS

Comprehensive Design Example 2: Foundations for Bulk Storage Facility

ITEM # OSTERBERG CELL LOAD TESTING OF DRILLED SHAFT

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

The demand for new roadway

Embedded Parts Introduction - Anchors

Helical Pier Foundation System U.S. Patents 5,011,336; 5,120,163; 5,213,448

ATLANTA MODEL SPECIFICATIONS

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

Quick fix for frost heave:

PATHWAY Classic Series with Handrails Portable Wheelchair Ramp INSTRUCTIONS FOR USE 6428 REV A

Soils, Foundations & Moisture Control

DESIGN, INSTALLATION AND TESTING OF HELICAL PILES & ANCHORS. Presented by: Donald A. Deardorff, P.E. CHANCE Civil Construction Centralia, MO USA

Guidelines for Earthquake Bracing Residential Water Heaters

3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form

SECTION 724 PIPE CULVERTS

Atlantic Foundation & Repair

DESIGNING STRUCTURES IN EXPANSIVE CLAY

Section 2100-Trenching and Tunneling

SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT

Geotechnical Building Works (GBW) Submission Requirements

GLOSSARY OF TERMINOLOGY

Helical Piles. A Practical Guide to Design and Installation

During severe flood events, such as those

HORIZONTAL INSTALLATION

Dock Hardware & Accessory Products Catalog

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

Safe & Sound Bridge Terminology

Design, Testing and Automated Monitoring of ACIP Piles in Residual Soils

Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE

The minimum reinforcement for the stem wall is the placement of:

MEMORANDUM West Swann Avenue, Suite 225 Tampa, Florida Phone (813) Fax (813)

METHOD STATEMENT HIGH STRIAN DYNAMIC TESTING OF PILE. Prepared by

Elevating Your House. Introduction CHAPTER 5

Owner s Manual Gantry Cranes

Anirudhan I.V. Geotechnical Solutions, Chennai

11 Guardrail. W-Beam Guardrail Pre-Installation Inspection During Installation Basis for Use. Modified Guardrail. End Treatments and Transitions

AstroSystems Digital Setting Circles for Zhumell, GSO, Apertura and Astro-Tech

IH-635 MANAGED LANES PROJECT, SEG. 3.2

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

6 RETROFITTING POST & PIER HOUSES

EROSPACE MOVING FORWARD WITH NBM W W W. N B M M E T A L S. C O M LEADING MANUFACTURER & MASTER DISTRIBUTOR OF BRASS, BRONZE, & COPPER ALLOYS

ENGLISH FORK GUIDE 2013

Transcription:

ATLAS RESISTANCE Pier Foundation Systems

Foundation Repair Systems for Civil Construction Applications: Residential, Commercial, Industrial Atlas Resistance Piers have been used to restore and/or stabilize homes and commercial structures that had settled due to a wide variety of soil problems. Foundation settlement and movement can be caused by building on expansive clay, compressible or improperly compacted fill soils, or improper maintenance around foundations. Whatever the cause, settlement can destroy the value of structures and render them unsafe. For sample specs, technical library, case histories and distributors, go to www.atlassys.com 2 Cost-effective rapid piers fit your job requirements Properly installed, Atlas Resistance Piers can prevent soil stratum. settlement, stabilize foundations and restore settled structures nearly to their original positions, often closing structural defects such as cracks and deformities caused by the the settlement. Because the solution is both permanent and economically attractive, the structures retain or recover their value. True end-bearing Atlas Resistance Piers are sold and installed only by contractors trained by Atlas and authorized to recommend and provide appropriate solutions to a wide range of soil problems. Design professionals may request a Chance Civil Construction Technical Design Manual on CD from their Distributor or Territory Manager listed on our web sites: www.atlassys.com or www.abchance.com. Verifiable factor of safety achieved on each pier as installed Reach competent soil below active zone Extendable in 3 1 / 2 -ft. No excavation or spoils to remove Loads may be immediately applied Installs in limited access Installs in any weather condition 0-35 kip 0-45.5 kip 0-55 kip 0-70.5 kip Pier Dia. 2 7 8 " 3 1 2 " 4" 4 1 2 " Installation by smooth hydraulic pressure extends pier to reach competent end-bearing Bracket Systems Applications Under Footing Continuous Lift Plate Pre-Drilled Helical Tieback Combo Page 3 Page 4 Page 5 Page 6 Page 7 Page 3 Page 4 Page 5 Page 6 Page 7 Page 3 Page 4 Page 5 Page 6 Page 7 Page 3 Page 4 Page 5 Page 6

Under Footing Bracket Systems For lifts up to 4" Standard-Series and N-Series models Under Footing Bracket Atlas Resistance Piers have 2 7 8 " to 4 1 2 " diameter pier with 0.165" to 0.237" wall thickness. Two-stage hydraulic installation develops end-bearing piers with a verifiable factor of safety. Multiple finishes and brackets are available. For more details, see the Chance Civil Construction Technical Design Manual, Bulletin 01-0605. Foundation stem wall N-Series Under Footing Bracket Standard Series Under Footing Bracket Concrete footing Mounting bolts (2, not included) Pier pins Building code structural provisions are met by some models of Atlas Resistance Pier Under Footing Bracket Systems which comply with the most recent editions of BOCA National Code, ICBO Uniform Code, SBCCI Standard Code and 2000 International Building and Residential Code as detailed in ICC Evaluation Service Legacy Report NER-579. 0-30 kip 0-35 kip 0-42.5 kip 0-45.5 kip 0-49 kip 0-70.5 kip Top pier platform Friction See Appendix C of the Chance Civil Construction Technical Design Manual, Bulletin 01-0605. Under Footing Bracket Systems Atlas Resistance Pier Sizes 2 7 8 " Pier Diameter 2 7 8 " Pier Diameter, Modified with reinforcing sleeve 3 1 2 " Pier Diameter 3 1 2 " Pier Diameter, Modified with reinforcing sleeve 4" Pier Diameter 4 1 2 " Pier Diameter 3

Continuous Lift Systems For lifts exceeding 4", bracket fits under footing Exceptional, extended lift capabilities Continuous Lift Bracket Atlas Resistance Piers have 2 7 8 " to 4" diameter pier with 0.165" to 0.219" wall thickness. Two-stage hydraulic installation develops end-bearing piers with a verifiable factor of safety. Multiple finishes are available. For more details, see the Chance Civil Construction Technical Design Manual, Bulletin 01-0605. Continuous thread bar Foundation stem wall Continuous Lift Bracket For sample specs, technical library, case histories and distributors, go to www.atlassys.com Concrete footing Mounting bolts (4, not included) Cap plate assembly Top pier sleeve Friction 4 Continuous Lift Plate Bracket Atlas Resistance Pier Systems also are available by special order. See page 5 for general information on Plate Bracket Systems. 0-20 kip 0-30.5 kip 0-50 kip Continuous Lift Bracket Systems Atlas Resistance Pier Sizes 2 7 8 " Pier Diameter 3 1 2 " Pier Diameter 4" Pier Diameter

Plate Bracket Systems Easy surface mount installation Also for round columns (custom manufactured) For lifts up to 4" Plate Bracket Atlas Resistance Piers have 2 7 8 " to 4 1 2 " diameter pier with 0.165" to 0.237" wall thickness. Two-stage hydraulic installation develops end-bearing piers with a verifiable factor of safety. Multiple finishes are available. For more details, see the Chance Civil Construction Technical Design Manual, Bulletin 01-0605. Foundation stem wall Plate Bracket Pier pins Mounting bolts (8, not included) Concrete footing Top pier platform Friction Continuous Lift Plate Bracket Atlas Resistance Pier Systems also are available by special order (see page 4). Pre-Drilled Plate Bracket Atlas Resistance Pier Systems also are available by special order (see page 6). 0-35 kip 0-45 kip 0-51.5 kip 0-56 kip Plate Bracket Systems Atlas Resistance Pier Sizes 2 7 8 " Pier Diameter 3 1 2 " Pier Diameter 4" Pier Diameter 4 1 2 " Pier Diameter 5

Pre-Drilled Systems For lifts up to 4" For penetrating unsuitable rock near surface For digger head clearance, drilled hole eccentricity may be 6 3 4 " from wall to pipe centerline Pre-Drilled Bracket Atlas Resistance Piers have 2 7 8 " to 4 1 2 " diameter pier with 0.165" to 0.237" wall thickness. Two-stage hydraulic installation develops end-bearing piers with a verifiable factor of safety. Multiple finishes are available. For more details, see the Chance Civil Construction Technical Design Manual, Bulletin 01-0605. Concrete footing Foundation stem wall For sample specs, technical library, case histories and distributors, go to www.atlassys.com Mounting bolts (4, not included) Pier pins Foundation stem wall Top pier platform Drilling through shallow rock layer permits this Pre-Drilled Pier Bracket System to reach load-bearing stratum below. Unsuitable Rock stratum or floater Top pier platform Friction Friction 6 Pre-Drilled Plate Bracket Atlas Resistance Pier Systems also are available by special order with capacities matching those listed below. See page 5 for general information on Plate Bracket Systems. 0-29 kip 0-31 kip 0-38 kip 0-46 kip Pre-Drilled Bracket Systems Atlas Resistance Pier Sizes 2 7 8 " Pier Diameter 3 1 2 " Pier Diameter 4" Pier Diameter 4 1 2 " Pier Diameter

Atlas Resistance Pier & Helical Tieback Combo For lateral support needed in conjunction with Atlas Resistance Pier Where site conditions and load requirements warrant, this system combines Chance helical tieback anchors with Atlas Resistance Piers. The helical anchors contribute lateral support to the piers providing vertical support. This unique combination forms a fast, effective solution for challenges beyond the capabilities of other systems. Components for a single unit include: Atlas Resistance Modified Pier and Bracket Chance Helical Tieback Anchor Bearing Plate Bevel Washer All-Thread Rebar and Nut Square Shaft-to-Threaded Bar Transition Coupling Concrete footing Foundation stem wall Chance Helical Tieback Anchor Lead Section and Extension Atlas Resistance Two-Piece Modified Pier Bracket Transition coupling All-thread rebar and nut Bevel washer Bearing plate Top pier platform Typical application Atlas Resistance 2-Piece Modified Pier and Bracket with integrated Chance Helical Tieback Anchor Friction *Pier Design Typic al Application Using A tlas Re sist anc e 2-Piece M odifi ed Piers with Integrated Chanc e Pier and Tieback Combo Bracket Systems Hel ical Tieba ck An chors. Atlas Resistance Modified Piers Chance Helical Tieback Anchors 0-35 kip 2 7 8 " Pier Diameter, reinforced top section 1 1 4 " RC Square Shaft SS125 Series 0-45.5 kip 3 1 2 " Pier Diameter, reinforced top section 1 1 2 " RC Square Shaft SS5 and SS150 Series 0-55 kip 4" Pier Diameter, reinforced top section 1 1 2 " RC Square Shaft SS5 and SS150 Series 1 3 4 " RC Square Shaft SS175 Series 7

Anchoring the World With both the CHANCE and ATLAS brands, Chance Civil Construction is the international leader in earth anchoring and structural mitigation. CHANCE Helical piles and ATLAS Resistance piers are used worldwide to secure residential and commercial buildings, tower foundations, heavy equipment foundations and many other deep foundation applications. Engineered for dependability and long-term stability, our systems feature exclusive anchoring techniques, tools, designs and sizes that make other foundation methods a thing of the past. Selected by application, our systems are your first line of defense against poor soil conditions, floods and time. Demand A Better Foundation With nearly 400 dealers and distributors nationwide and in Canada, we are ready to provide you everything you need to get the job done right. We offer engineering guidance, field supervision, accessibility, warehouses, material traceability, AWCcertified welders, technical support and complete documentation. Ask a distributor near you for our comprehensive design manual (hardcopy or CD) or download a complete Sample Specification Guide online. Demand a better foundation today. Locate your nearest distributor at our web sites below. Down. Right. Solid. Our tagline is our promise. Our foundation and anchoring products go down with power into the ground and are accurate, level and right the first time. The result is solid stability. www.abchance.com www.atlassys.com 210 North Allen Street Centralia, MO 65240 Tel. (573) 682-8414 Fax (573) 682-8660 Because Hubbell has a policy of continuous product improvement, we reserve the right to change design and specifications without notice. Copyright 2008 Hubbell, Inc. / Printed in USA / A&J10M03/08 / Bulletin 01-0701