CHLORAMINE FACT SHEET

Similar documents
PPCP & EDC FACT SHEET

Supporting Guidance (WAT-SG-41)

EPB 311- Strategies for Dealing with Groundwater Treatment Systems Having High Natural Ammonia

Parts per million (ppm) or Milligrams per liter (mg/l): one part by weight of analyte to 1 million parts by weight of the water sample.

Chemicals in Drinking Water: Chloramines

8 Chemicals from water treatment and distribution

Trichloramine and Asthma in Swimming pools & spas Problem solved

Removal of Chlorine Residual in Tap Water by Boiling or Adding Ascorbic Acid

Dissolved Mineral Radioactivity in Drinking Water

FACTS. Nitrate and Nitrite in Drinking Water. What Are Nitrate and Nitrite? 3. How Can These Chemicals Get into Your Drinking Water?

Standard methods in water analysis

Basic Chemistry of Chlorination

2010 Annual Drinking Water Quality Report Collier County Water Department

Water Info. What is Reverse Osmosis?

What is Chlorination?

Public Water System. Consumer Confidence Report Template

Treatment options for hydrogen sulfide. Testing for hydrogen sulfide

2015 Annual Drinking Water Quality Report of the Englewood Water District

Annual. Water testing performed in Presented By PWS ID#: FL

Nitrate and Nitrite Removal from Municipal Drinking Water Supplies with Electrodialysis Reversal

Chlorine, Total. DPD Method 1 Method to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information

Removal of Residual Chlorine from Drinking-Water By Solar Radiation (UV) and Activated Carbon Filtration

Trace organic contaminant removal from drinking water using local char

water quality 2007 annual report Huntington District Our Customer Charter Dear West Virginia American Water Customer,

Storage-stable Aqueous Solutions of Chlorine Dioxide

The uses of chlorine dioxide exploit the advantages over chlorine. The main applications are detailed below, along with any additional information.

Water. Quality. Report. Water Resources Department

UV Treatment of Swimming Pool Water

2009 Drinking Water Quality Report The University of Kansas - Lawrence Campus - July 2010

Sarah Chung, Ken Oliphant, Patrick Vibien and Jingguo Zhang Jana Laboratories Inc., Aurora, Ontario, Canada

How to measure Ammonia and Organic Nitrogen: Kjeldahl Method

Nitrification TCEQ. Public Drinking Water Conference Austin, Texas August 16, A System s Perspective after 20 years of Chloramination

NITRATE. is found in the Honolulu Board of Water Supply REGION 3 (Ewa-Waianae-Waipahu System). Here are the EPA s Health Effects for this contaminant,

Healthy Drinking Waters

The Ultimate Swimming Experience

2015 Annual Drinking Water Quality Report Water System Number:

Chemistry at Work. How Chemistry is used in the Water Service

CHLORINE DIOXIDE. R.A. Deininger A. Ancheta A. Ziegler School of Public Health The University of Michigan Ann Arbor, Michigan, USA ABSTRACT

Texas Commission on Environmental Quality Page 1 Chapter Public Drinking Water

Saving water means saving money; Fix those leaks right away. Community Water Company of Green Valley. Our Water Source

Testing Water for Gardening and Lawn Irrigation

DENVER, CO. WHAT S ON TAP? Grading Drinking Water in U.S. Cities June 2003 KEY CONTAMINANTS IN DENVER S WATER DENVER

Chemical Feed Systems Best Practices

2011 Drinking Water Quality Report for Nellis Air Force Base

PPM or ORP: Which Should Be Used?

WHO/SDE/WSH/03.04/83 English only Monochloramine in Drinking-water

Where does my water come from? Harrisonburg 2013 Hardness Levels

YOUr 2013 Water Quality REport

Introduction. Creating Water Quality Confidence. Sample Communication and Guidance - Natural Treatment. Terminology Guidelines

Guidelines for Arsenic Removal Treatment for Small Public Drinking Water Systems

Total Suspended Solids Total Dissolved Solids Hardness

Complete. Water Solutions. for Rural India

The First Step in Effluent Treatment

Drinking Water Treatment Systems

Iron and manganese are two similar elements

MDH Evaluation of Point-of-Use Water Treatment Devices for Perfluorochemical Removal Final Report - Summary

Lead and Copper Corrosion Control in New Construction [Project #4164]

New Jersey Private Well Water Test Reporting Form

Kemisan Water and Wastewater Disinfection Technologies. HypoX. HYPOCHLOROZONE Chlorine Oxygen based Disinfectant

Water Purification Treatment. General Information. Water Purification Treatment Business of the Teijin Group. Water. Purification Treatment

FACTS Private Well Testing

Cyanotoxin Removal in Drinking. Recreational Waters. Judy Westrick April 14, Northeast Regional Cyanobacteria Workshop

1) Alkalinity ) ph ) Colour ) Heterotrophic Plate Count ) Residual Chlorine ) Sulphate ) Nitrate...

Calculating Atoms, Ions, or Molecules Using Moles

GUIDELINES FOR LEACHATE CONTROL

Glenview School District 34 - Lead in Drinking Water FAQ

EDINBORO WATER AUTHORITY

Presented by Paul Krauth Utah DEQ. Salt Lake Countywide Watershed Symposium October 28-29, 2008

Iron and Manganese BACTERIA AND IRON AND MANGANESE

Removing Heavy Metals from Wastewater

Customer application report

FINAL EVENT LIFE+ BIOMOMI BIO-MONITORING AND AUTOMATIC MICROBIOLOGICAL CONTAMINATION CONTROL SYSTEM OF INDUSTRIAL HYDRAULIC CIRCUITS

FACT SHEET PROPOSED MERCURY AND AIR TOXICS STANDARDS

Water Treatment NOTES. Cornell Cooperative Extension, College of Human Ecology. Iron and Manganese in Household Drinking Water

Watts Family of water quality improvement products and equipment for whole house water treatment.

Balancing Chemical Equations

How To Ensure Safety At A Swimming Pool Or Spa

Balancing chemical reaction equations (stoichiometry)

More inside :: Tackle even the toughest water treatment piping challenges with

1. PUBLIC HEALTH STATEMENT

OSMOSIS AND DIALYSIS 2003 BY Wendy Weeks-Galindo with modifications by David A. Katz

Unit 9 Compounds Molecules

Comparison of natural radioactivity removal methods for drinking water supplies: A review

Division of Epidemiology, Environmental and Occupational Health Consumer and Environmental Health Services

UNCONVENTIONAL METHODS FOR PROVIDING SAFE DRINKING WATER IN SMALL SYSTEMS: ARSENIC REMOVAL DEMONSTRATION

Name Date Class STOICHIOMETRY. SECTION 12.1 THE ARITHMETIC OF EQUATIONS (pages )

A Report on Your Water Quality

A meaningful, cost-effective solution for polishing reverse osmosis permeate

Transcription:

International Headquarters & Laboratory Phone 630 505 0160 CHLORAMINE FACT SHEET WWW.WQA.ORG A not-for-profit organization Contaminant In Water As Maximum Residual Disinfectant Level Monochloramine Dichloramine Nitrogen trichloride NH2Cl NHCl2 NCl3 US EPA: MRDL* = 4.0 mg/l or ppm (measured as Cl2) MRDLG** = 4.0 mg/l or ppm (measured as Cl2) Sources of Contaminant Potential Health Effects Treatment Methods Point-of-Entry Point-of-Use Municipal Treatment Can cause hemolytic anemia when present in dialysis process water Activated Carbon Catalytic Activated Carbon *Maximum Residual Disinfectant Level (MRDL) - The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants. **Maximum Residual Disinfectant Level Goal (MRDLG) - The level of a drinking water disinfectant below which there is no known or expected risk to health. MRDLGs do not reflect the benefits of the use of disinfectants to control microbial contaminants.) Aqueous chlorine reacts with certain organic materials present in water sources to form trihalomethanes (THMs). Long-term exposure to these harmful byproducts of disinfection has been linked to an increased risk of cancer and infant birth delivery problems. It is estimated that THMs in drinking water are responsible for as many as 2-17 percent of the bladder cancers diagnosed each year in the United States. To protect the public, the U.S. Environmental Protection Agency has established a maximum contaminant level of 0.08 milligrams per liter (mg/l) for THMs. To conform to these regulations, many municipal water supplies have switched to an alternative method of disinfection using chloramination; more than 1 in 5 Americans uses drinking water treated with chloramines. Chloramination involves the addition of anhydrous or aqueous ammonia (NH 3) before or after the addition of chlorine (HOCl) to produce monochloramine (NH 2Cl). This reaction is as follows: NH 3 + HOCl = NH 2Cl + H 2O Chloramines also form to a lesser extent during conventional chlorine treatment when aqueous chlorine reacts with natural organic nitrogen. Monochloramine is 200 times less effective as a disinfectant than chlorine, but is an attractive alternative since it does not react as readily with organic

WQA Technical Fact Sheet: Chloramine materials to form THMs. Many water utilities overcome the decreased efficiency of monochloramine by dosing first with chlorine, then adding ammonia at a later stage of treatment. Since the initial application is of chlorine, this increases the initial biocidal efficiency of the disinfection but also increases the risk of THM formation during this initial treatment. The ammonia addition results in the residual chemical in the plumbing being monochloramine, with longer lasting residual and reduced risk of THM formation in the distribution system. The process of chloramination is both ph and concentration dependent. Water ph levels below 7.5 or chlorine to ammonia weight ratios exceeding 5:1 increase the formation of dichloramine (NHCl 2) and nitrogen trichloride (NCl 3). Dichloramine and nitrogen trichloride are undesirable byproducts in that while they are more effective disinfectants, they are less stable and cause greater swimming pool - type taste and odor problems when they exceed concentrations of 0.80 mg/l and 0.02 mg/l (respectively). Excessive chlorine levels produce THMs, while excess ammonia increases the potential for nitrification in the distribution system. The US EPA recognizes three analytical methods as acceptable for measuring residual chloramines. These methods are: Amperometric Titration (Standard Method 4500-C1 D and ASTM Method D 1253-86) DPD Ferrous Titrimetric (Standard Method 4500-C1 F) DPD Colorimetric (Standard Method 4500-C1 G) The average municipal water system maintains residual monochloramine concentrations around 2 mg/l (range: 1.5 mg/l to 2.5 mg/l). Chloramination also has the added benefit of decreasing the formation of biofilms in water supply systems since the residual levels of monochloramine remain relatively constant throughout the system HEALTH EFFECTS Although the use of chloramination has recently increased, it has a long history of safe and effective use in the United States. The City of Denver, Colorado has utilized chloramination since 1918. An extensive risk assessment by the EPA s National Center for Environmental Assessment (NCEA) utilized existing human and animal studies to conclude that human health effect do not appear to be associated with levels of residual chloramines typically found in drinking water. However, a Maximum Residual Disinfectant Level Goal (MRDLG) and Maximum Residual Disinfectant Level (MRDL) of 4.0 mg/l was established by US EPA as the enforceable maximum safety level for chloramines (measured as chlorine, Cl 2) for public water systems under the Safe Drinking Water Act, and the level below which there is no known or expected risk to health. Chloramines do pose a risk for hemodialysis patients and fish. Chloramines easily enter the bloodstream through dialysis membranes and the gills of fish. Once in the blood stream, chloramines denature hemoglobin and cause hemolytic anemia. Accidental use of chloramine treated water for dialysis has been responsible for a number of patients requiring transfusion to treat resultant hemolytic anemia, and was a possible factor in an increased mortality (death) rate among the dialysis center

WQA Technical Fact Sheet: Chloramine patients during the 5 months after the chloramine exposure when compared to the 12 months before the chloramine exposure. Nitrosamines can be generated as byproducts from use of chloramines. They are strongly suspected of being human carcinogens. Nitrosamines can come in contact with most of organs in the body in addition to crossing the placenta. Effects such as cell damage and DNA mutations may occur and lead to cancer even at low levels of exposure. TREATMENT METHODS Residential Point-of-Use Point-of-Entry Municipal Activated Carbon Catalytic Activated Carbon N/A Visit WQA.org to search for products certified to NSF 42 for chloramine reduction. While chloramines are not a drinking water health concern to humans generally, their removal improves the taste and odor of drinking water. Chloramines are small, stable molecules with no net charge making them difficult to remove by distillation, reverse osmosis, and ion exchange resins. Due to the reaction of aqueous chlorine with organic nitrogen, chloramines also present a concern for municipal water systems utilizing chlorine as a method of disinfection. This reaction is of concern because there is potential for harmful disinfection byproducts to be produced from it. The most effective nonchemical method for removing chloramines is by activated carbon (C*). Activated carbon does not adsorb chloramines but rather removes them through its ability to act as a catalyst for the chemical breakdown of chloramines to innocuous chlorides in water. This catalytic reaction involves the formation of an oxide of carbon intermediate (CO*). This reaction is as follows: NH 2Cl + H 2O + C* = NH 3 + Cl - + H + + CO* 2NH 2Cl + CO*= N 2 + 2Cl - + 2H + + H 2O + C* Fine mesh sizes of activated carbon remove chloramines more efficiently since they have greater surface areas and allow faster access to catalytic sites. Also, activated carbon that has been acclimated to achieve increased sites for oxide of carbon intermediate (CO*) formation improves chloramine removal. For new activated carbon, initial dosing with chlorine to preoxidize the carbon may result in more effective chloramine removal, as shown in the second reaction above. A bed contact time of 10 minutes or greater can be required for complete catalysis of chloramines with traditional activated carbons. New types of activated carbons have been developed with increased catalytic activity that is especially effective at the removal of chloramines. These catalytic carbons may be marketed with a peroxide number (rate of hydrogen peroxide decomposition) in addition to the traditional iodine

adsorption number. The chloramine removal capacity of activated carbon is dependent upon ph. Catalytic carbons have demonstrated increased chloramine removal efficiency at higher phs. Ammonia (NH 3), chloride (Cl - ), and nitrogen gas (N 2) are produced by the catalysis of monochloramine. The removal of these catalytic byproducts can be achieved by additional treatment with ion exchange resins or by reverse osmosis. The treatment methods listed herein are generally recognized as techniques that can effectively reduce the listed contaminants sufficiently to meet or exceed the relevant MCL. However, this list does not reflect the fact that point-of-use/point-of-entry (POU/POE) devices and systems currently on the market may differ widely in their effectiveness in treating specific contaminants, and performance may vary from application to application. Therefore, selection of a particular device or system for health contaminant reduction should be made only after careful investigation of its performance capabilities based on results from competent equipment validation testing for the specific contaminant to be reduced. As part of point-of-entry treatment system installation procedures, system performance characteristics should be verified by tests conducted under established test procedures and water analysis. Thereafter, the resulting water should be monitored periodically to verify continued performance. The application of the water treatment equipment must be controlled diligently to ensure that acceptable feed water conditions and equipment capacity are not exceeded. Visit WQA.org to locate water professionals in your area. Note that Certified Water Specialists have passed the water treatment education program with the Water Quality Association and continue their education with recertification every 3 years. REGULATIONS In the United States the EPA, under the authority of the Safe Drinking Water Act (SDWA), has set the Maximum Residual Disinfectant Level (MRDL) for chloramines (measured as Cl 2) at 4.0 mg/l. Disinfection byproducts are also regulated under the SDWA, and the MCL for total THMs is 0.08 mg/l. The utility must take certain steps to correct the problem if the tap water exceeds these limits and they must notify citizens of all violations of the standard. REFERENCES/SOURCES Bauer, R.C. and V.L. Snoeyink, Journal Water Pollution Control Federation, 45:2290 (1973). Safe Drinking Water Act Amendments of 1996. Public Law 104-182. (Aug. 6, 1996). Tripple MA, Shusterman N, Bland LA, McCarthy MA, Favero MS, Arduino MJ, Reid MH, Jarvis WR; Illness in hemodialysis patients after exposure to chloramine contaminated dialysate; Hospital Infections Program, Center for Infectious Diseases, Atlanta, Georgia 30333; ASAIO

Trans. 1991 Oct-Dec: 37 (4): 588-91. U.S. EPA.Drinking Water Criteria Document for Chloramines. ECAO-CIN-DOO2, (March, 1994). U.S. EPA. 1999. EPA Guidance Manual: Alternative Disinfectants and Oxidants. EPA815R99014, (April 1999). U.S. EPA. 1998. National Primary Drinking Water Regulations: Disinfectant and Disinfectant Byproducts Notice of Data Availability; Proposed Rule, Federal Register 63 (61): 15673-15692 U.S. EPA, 2006. National Primary Drinking Water Regulations: Stage 2 Disinfectants and Disinfection Byproducts Rule; Federal Register 71: 388-493 WHO (2004). Monochloramine in Drinking Water. http://www.who.int/water_sanitation_health/dwq/chemicals/en/monochloramine.pdf Xu Xu and Clifford Weisel (2005). Human respiratory uptake of chlororform and haloketones during showering. Journal of Exposure Analysis and Environmental Epidemiology. Xu Xu and Clifford Weisel (2005). Dermal uptake of chloroform and haloketones during bathing. Journal of Exposure Analysis and Environmental Epidemiology. ACKNOWLEDGEMENT WQA wishes to express sincere appreciation for the unselfish contributions of the members of WQA who contributed their time and expertise toward the completion of this bulletin. Arvind Patil, Ph.D., CWS-I Gary Hatch, Ph.D. Charles Michaud, CWS-VI Mark Brotman, CWS-VI P. Regunathan, Ph.D. Rebecca Tallon, P.E. Richard Andrew Shannon Murphy Steve VerStrat Pauli Undesser, M.S., CWS-VI Kimberly Redden, CWS-VI The Water Quality Association publishes this Technical Application Bulletin as a service to its members and the interested public. Information contained herein is based upon the most recent public data known as of the publication date and cannot take into account relevant data published thereafter. The Water Quality Association makes no recommendations for the selection of a treatment system, and expressly disclaims any responsibility for the results of the use of any treatment method or device to reduce or remove a particular contaminant. This reference document is published by: National Headquarters & Laboratory 4151 Naperville Road Lisle, Illinois 60532 Tel: 630 505 0160 Fax: 630 505 9637 Copyright 2013 by Water Quality Association. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electric, mechanical, photocopying, recording, or otherwise, without the prior written permission of the publisher.