SNMP INTERFACES AND SOFTWARE FOR SINGLE-PHASE UPS



Similar documents
UPS Management Software

Communication and connectivity the ideal solution for integrated system management and data integrity

Network Management Card. User Manual

UPS MANAGEMENT SOFTWARE

UPS MANAGEMENT SOFTWARE OPTIONS

Description UPS Management Software

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

NetAgent. UPS SNMP Agent. User s Manual

Software and accessories

SNMP Web Management. User s Manual For SNMP Web Card/Box

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Connectivity. PowerShield 3. Communications Software

User s Manual Network Management Card

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

PowerGem Pro Uninterruptible Power Supply

*Compatible with MPI series grid-tied inverters

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

SNMP-NET UPS SNMP Card (Web-Based monitoring SNMP Card)

Options and monitoring

50-Port 10/100/1000Mbps with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

Secure Power Always. Agility Series UPS ( VA) Chloride Connectivity Solutions. Product data sheet

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

HWg-STE HWg-STE PoE MANUAL

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

8/16-Port IP KVM Switch IKVM-8010 / IKVM Quick Installation Guide

SentryPlus. Shutdown Management Software for Windows. User s Manual

Sentry Bulldog Shutdown Management Software (For UNIX Series)

Ha-VIS FTS 3000 Introduction and features

The Leading KVM Switch Solutions Provider, ATEN

POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Title Page Web/SNMP Management SmartSlot Card

Remote Monitoring Unit SC8100. Monitoring Unit SC8100

User s Manual. Remote Management Card

Uninterruptible Power Supply

Access Control and Operating Conditions Monitoring System for Telecommunication and Server Racks

User s Manual UPS SERIES. Network Interface Card UPS-IPCARD. I Rev B

WebPower UPS SNMP HTTP AGENT

Connecting to the network

Poseidon MANUAL

Data Loggers for Real Time Temperature Monitoring - WiFi

Network Management Card

QuickSpecs. Models. HP UPS Management Module. HP UPS Management Module. Overview

M400gsm GSM Modem Datasheet

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

Remote Management Card

How To Run An Nport I5000A Device Server

User s Manual. Remote Management Card RMCARD202. Intelligent Remote Management Card allows a UPS system to be managed, monitored, and configured

HP UPS Management Module Overview

Product Description... 1 Internal Management Features... 3 Front Panel... 5 Watchdog Features... 7

PowerCommand iwatch 100 Remote Network Monitoring

DL TC72 Communication Protocols: HDLC, SDLC, X.25, Frame Relay, ATM

SNMP-SSL UPS SNMP Card (Web-Based monitoring SNMP Card) User s Manual

Indoor / Outdoor Antenna

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

Dell Network Management Card. User's Guide. w w w. d e l l. c o m s u p p o r t. d e l l. c o m

Network Management Proxy 5 User manual

NetAgent. UPS SNMP Agent. User s Manual

AC 750. Wireless Dual Band 4G LTE Router. Highlights

Network Management Card

Smart-UPS On-Line 230 V

Installation and Configuration User's Guide

securityprobe 5E Standard

EMS. Trap Collection Active Alarm Alarms sent by & SMS. Location, status and serial numbers of all assets can be managed and exported

HARTING mcon 1000 Introduction and features

User and Installation Manual

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

Winpower. User Manual.

ViewPower User Manual

How To Set Up Power Supply On Windows (Windows) With Powerup (Windows 8) On Windows 7.1) On A Pc Or Windows 8 (Windows 7) On An Ipad Or Ipad (Windows Xp

SNMP-NET Client Shutdown Management Software for Windows 2000/XP/2003 User s Manual

AC 750. Wireless Dual Band ADSL2+ Modem Router. Highlights

User s Guide. PowerAlert Software Versions / /

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Powerware Series. Eaton ConnectUPS Web/SNMP Card User's Guide X, BD, and E Models

Machine-to-Machine Management System. Datasheet. Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw

InsightPower Client. Shutdown Management Software for Windows 2000/XP/2003. User s Manual

AC Wireless Dual Band ADSL2+ Modem Router. Highlights

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Belkin Bulldog Plus. Shutdown Management Software for Windows. User s Manual

PN5212/PN5320/PN7212/PN7320

Product Guide CM-Relay

Computer Cabinet Environment Monitor

Lecture (02) Networking Model (TCP/IP) Networking Standard (OSI) (I)

User s Manual. Management Software for Uninterruptible Power Supply Systems

TereScope Management Options

Cisco Small Business Managed Switches

SNC-VL10P Video Network Camera

INTELLECT TM Software Package

1 Data information is sent onto the network cable using which of the following? A Communication protocol B Data packet

UPS Monitoring Software User Manual. Emily2

UPS MONITORING SOFTWARE USER MANUAL

Cisco SRW2024P 24-Port Gigabit Switch: WebView/PoE Cisco Small Business Managed Switches

Follow these steps to prepare the module and evaluation board for testing.

Transcription:

SNMP INTERFACES AND SOFTWARE FOR SINGLE-PHASE UPS NetAgent (connection through RJ45 LAN network) NetAgent is an SNMP (Simple Network Management Protocol) interface that enables connection and configuration of the UPS in a LAN computer network. The SNMP interfaces for single phase UPS are supplied complete with CD containing the software required to monitor and manage the UPS through the LAN. NetAgent is available in three versions: Mini internal model compatible with UPS of the EVO RT series (code: FGCNETAG2IN). Internal slot model compatible with UPS of the EVO DSP MM series (code: FGCNETAG7). External model to connect to the RS232 port of the UPS (code: FGCNETAG2). Contents of the CD supplied with the interface: Netility: to rapidly configure the IP of the interface and update the firmware (compatible with Windows, Linux and Mac). ClientMate: for managing shutdown of the computers connected to the network (compatible with Windows, Linux, Mac, FreeBSD and VMWare). SNMPView: to monitor several UPS simultaneously (compatible with Windows). UPS MIB: to control and monitor the UPS through SCADA (Supervisory Control and Data Acquisition) systems. Automatic computer shutdown Ordered file saving Control and configuration through Telnet, Web Browser or NMS. Supports protocols: TCP/IP, UDP, SNMP, Telnet, SNTP, PPP, HTTP and SMTP. Simultaneous transmission of SNMP TRAP and e-mails of all events. Manages the MIB SNMP to monitor and control the UPS. Autoselection 10Mbit/100Mbit Fast Ethernet. Forwarding of daily e-mails with the history of UPS events. IP configuration through Netility Software ClientMate NetAgent Web Manager

SNMP INTERFACES AND SOFTWARE FOR SINGLE-PHASE UPS NetAgent (connection through RJ45 LAN network) Specification SNMP FGCNETAG2IN INTERNAL SNMP FOR UPS EVO FGCNETAG2IN EVO 1.0 RT - 2.0 RT - 3.0 RT Internal SNMP Interface, CD, installation manual CD content Netility, ClientMate, SNMPView, UPS MIB Specification SNMP FGCNETAG2 CD content EXTERNAL SNMP FOR SINGLE PHASE UPS FGCNETAG2 ERA LCD 1.5-2.0-2.6 EVO 1.0 RT - 2.0 RT - 3.0 RT, EVO DSP MM External SNMP interface, CD, installation manual, power supply Netility, ClientMate, SNMPView, UPS MIB Specification SNMP FGCNETAG7 CD content SNMP FOR UPS EVO DSP MM FGCNETAG7 EVO DSP MM 1.2-2.4-3.6-6.0-10.0-6.0 RM - 10.0 RM Internal arranged in slot SNMP interface, CD, installation manual Netility, Clientmate, SNMPView, UPS MIB

UPS COMMUNICATION SOFTWARE FOR SINGLE PHASE UPS Software UPSilon 2000 (connection via RS232 port or USB) UPSilon 2000 is professional software for the correct management of a UPS. The status of the power supply, the operation of the UPS, the charge level and the efficiency of the batteries can be controlled in real time through the RS232 serial port or USB. In the event of anomalies in the power supply, UPSilon 2000 will automatically proceed to save all the open files and will then close down the operating system and switch off the computer in an ordered manner, before the autonomy runtime of the UPS expires. In addition, UPSilon 2000 monitors, analyses and records a vast range of parameters related to the operation of the UPS. It visualises in real time, in the form of a graph, the input/output voltage, frequency and charge connected to the UPS, the working temperature and the charge level of the batteries. UPSilon 2000 is compatible with the UPS of the series ECO STRIP, ERA LCD, EXA and EVO DSP MM. RS232/USB Local workplace Operating systems supported: Windows 2000, 2003 Server, XP, Vista, 2008 Server, 7 Linux Novell Netware 3.x, 4.x, 5.x, 6.x Mac OS X Unix FreeBSD Detection via RS232 port or USB of the conditions of no power supply or run-down batteries. Automatic shutdown of the system when autonomy runtime expires. Setting of times for alarm notification and automatic shutdown. Complete switch-off of the UPS after shutdown to protect battery capacity. Signalling of power supply anomalies via broadcast messages, e-mails and SMS. Command file execution. Programming of the start/shutdown times. Local control via RS232 port or USB. Remote viewing via TCP/IP protocol. Registration of the events for analysis. Multilingual version. Main window Block diagrams Graphs Parameter measurements

DRY CONTACT SINGLE PHASE UPS Dry Contact board Dry Contact board provides a set of relay contacts (Dry Contacts) able to identify UPS alarm status as battery mode, discharged battery, active bypass or general alarm. The Dry Contact are available in two versions: Dry Contact Kit compatible with UPS EVO RT series (code: FGCEVODRY1) Dry Contact slot compatible with UPS EVO DSP MM series (code: FGCEVODSDRY3) SCADA Specification DRY CONTACT FGCEVODRY1 Equipped with Interface connector Reports DRY CONTACT FOR EVO 1.0 RT - 2.0 RT - 3.0 RT FGCEVODRY1 EVO 1.0 RT - 2.0 RT - 3.0 RT Internal Installation Kit, user manual Terminal block AC fail, Low Battery, Fault, Bypass active Specification DRY CONTACT FGCEVODSDRY3 Equipped with Interface connector Reports DRY CONTACT FOR EVO DSP MM FGCEVODSDRY3 EVO DSP MM 1.2-2.4-3.6-6.0-10.0-6.0 RM - 10.0 RM Internal arranged in slot Dry Contact interface, user manual Terminal block DB9 female AC fail, Low Battery, Fault, Bypass active

SNMP INTERFACES AND SOFTWARE FOR NetAgent (connection through RJ45 LAN network) The SNMP (Simple Network Management Protocol) interface enables connection and configuration of the UPS in a LAN computer network. The SNMP interface for UPS EVO DSP TT and TM is an internal slot model (code FGCNETAG6) that does not require any software for managing and viewing the operational status of the UPS. The IP can in fact be configured through the browser to set up a dialogue with the UPS, carry out battery tests, checks on the UPS operation, scheduling of shutdowns and starts, and the forwarding via e-mail or SMS of information on the operational status. Risc 32 bit processor. Control and configuration through Telnet, Web Browser. Supports protocols: IPv4/6, TCP/IP, SNMP, HTTP and SMTP. Simultaneous transmission of SNMP TRAP and e-mails of all events. Manages the MIB SNMP to monitor and control the UPS (RFC1628). Autoselection 10Mbit/100Mbit Fast Ethernet. Management of history of events and data. Operational status of the UPS System status Events configuration Specification SNMP FGCNETAG6 INTERNAL SNMP FOR UPS FGCNETAG6 Internal arranged in slot Installation manual

SNMP INTERFACES AND SOFTWARE FOR UPS Management (code FGCSWUMSU) UPS Management is a set of software contained in a CD that can be used to interface with the NetAgent card (code FGCNETAG6). Contents of the UPS Management CD: UPSMAN: advanced software for monitoring the operational status of the UPS. RCCMD: for managing shutdown of the computers connected to the network. 1 licence for the RCCMD software. In order to manage a number of computers on the network, an RCCMD licence must be purchased for each computer (licence code FGCSWUMMS). Automatic shutdown of the computers (via RCCMD). Ordered file saving. Management of an unlimited number of clients. Management of events. Security measures for client utilisation. Control interface Graphs Operational status of the UPS Specification Software FGCSWUMSU SOFTWARE UPSMAN INTERFACING UPS FGCSWUMSU UPS compatibility Contents Upsman UPS management + RCCMD Client for Client management + 1 license for RCCMD SO compatibility Windows, Unix System, Mac OS X Specification Software FGCSWUMMS LICENCE FOR RCCMD CLIENT FGCSWUMMS UPS compatibility Contenuts License for RCCMD Client SO compatibility Windows, Unix System, Mac OS X

REMOTE PANEL FOR Remote panel The Tecnoware remote panel (code FGCEVODSRP1) is compatible with the UPS of the series EVO DSP TM/TT. It enables the operational values of the UPS to be viewed and monitored even from a remote location. The remote panel is connected to the UPS by a serial cable. Depending on the installation distance, one of the two available communication standards - RS232 or RS485 - can be selected. If the length of the cable is 25 m or less then the RS232 should be used; if the length of the cable is over 25 m (up to a maximum of 100 m) then the RS485 communication must be used. For distances of up to 25 m Tecnoware can supply a suitable cable (product code: FGCEVODSCARP1). The remote panel has an internal battery that guarantees continuity even in the event of blackouts, so as to ensure control of the UPS even in the case of power cuts. It is also possible to control the history of events, launch battery tests and monitor the battery status from the remote panel. REMOTE PANEL Specification FGCEVODSRP1 UPS Features and specifi cation REMOTE PANEL FOR UPS FGCEVODSRP1 Powered by AC mains - Internal battery to ensure the correct functioning in case of blackout - Complete control of UPS and interaction with UPS by remoting LCD display and leds to visualise UPS operating modes 12 months Specification FGCEVODSCARP1 UPS Length Connector type REMOTE PANEL CABLE FOR EVO DSP LENGHT 25M FGCEVODSCARP1 25 m DB9-RS232 12 months