3. Roles and responsibilities



Similar documents
N26 Chest Tubes 5/9/2012

CHEST TUBES AND CHEST DRAINAGE SYSTEMS

INTERDISCIPLINARY CLINICAL MANUAL Policy & Procedure

NHS FORTH VALLEY Chest Drain Insertion by Seldinger Method (Pigtail drains)

RATIFIED BY NNPDG SEPTEMBER 2006 FOR REVIEW 2009

Caring for a Tenckhoff Catheter

CHEST TUBE REVIEW Orientation Package

X-Plain Subclavian Inserted Central Catheter (SICC Line) Reference Summary

Paediatric Intensive Care Unit Nursing Procedure: Care of Arterial Lines.

NEEDLE THORACENTESIS Pneumothorax / Hemothorax

The planners of the educational activity have no conflicts of interest to disclose.

Information for patients and nurses

Management of Chest Tubes and Air Leaks after Lung Resection

Tunnelled indwelling pleural catheter (TIPC)

Troubleshooting a Patient with a Chest Drain. A Simulation Workshop

Oxygenation. Chapter 21. Anatomy and Physiology of Breathing. Anatomy and Physiology of Breathing*

Caring for a Hemovac Drain

Patient Information Guide Morpheus CT Peripherally Inserted Central Catheter

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

Guidelines for the Insertion and Management of Chest Drains

Percutaneous Nephrostomy. Care of your Nephrostomy. Department of Urology

Measuring central venous pressure

Enables MDA Medical Teams to categorize victims in mass casualty scenarios, in order to be able to triage and treat casualties

PICC & Midline Catheters Patient Information Guide

Flushing and Dressing a Peripherally Inserted Central Catheter (PICC Line): a Guide for Nurses

BARD MEDICAL DIVISION UROLOGICAL DRAINAGE. Foley Catheter Care & Maintenance. Patient Education Guide

All About Your Peripherally Inserted Central Catheter (PICC)

CUESTA COLLEGE REGISTERED NURSING PROGRAM CRITICAL ELEMENTS

Cardiac Catheterisation. Cardiology

Simple Thoracostomy Avoids Chest Drain Insertion in Prehospital Trauma

X-Plain Foley Catheter Male Reference Summary

Central venous catheters. Care of the site 88 CVP measurement 90 Removal of CVC (non-tunnelled) 93 Care of long-term CVCs 95

Introduction A JP Drain is a soft tube and container used to drain fluids that build up under the skin after surgery.

PATIENT GUIDE. Understand and care for your peripherally inserted central venous catheter (PICC). MEDICAL

PICCs and Midline Catheters

NORTH CAROLINA BOARD OF NURSING NURSE AIDE II TRAINING MODULE

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

Epidural Management. Policy/Purpose. Scope

GUIDELINE ON THE CARE OF CHILDREN WITH CHEST DRAINS

Caring for Your PleurX Pleural Catheter

PARAMEDIC TRAINING CLINICAL OBJECTIVES

RGN JOY LAUDE WATFORD GENERAL HOSPITAL, ENGLAND

AUSTRALIAN AND NEW ZEALAND COLLEGE OF ANAESTHETISTS ABN RECOMMENDATIONS FOR THE POST-ANAESTHESIA RECOVERY ROOM

Policies & Procedures. Care of

Status: Standard Procedure: specifies the procedures to be followed, only in exceptional circumstances should these not be followed

by Patricia Carroll, RN, BC, CEN, RRT Used with Written Permission by Jeffrey P. McGill

Going Home with a Urinary Catheter

Your Guide to Peritoneal Dialysis Module 3: Doing Peritoneal Dialysis at Home

Within the Scope of Practice/Role of APRN RN _ X_LPN CNA

PERIPHERALLY INSERTED CENTRAL CATHETERS (PICC) Fong So Kwan APN, Haematology unit Medical Department, QMH

Care for your child s Central Venous Catheter (CVC)

Atrium Pneumostat Chest Drain Valve. Discharge Instructions

How To Recover From A Surgical Wound From A Cast

How To Treat A Heart Attack

Spinal Cord and Bladder Management Male: Intermittent Catheter

Understanding your Peripherally Inserted Central Catheter (PICC) Patient Information

Guy s, King s and St Thomas Cancer Centre The Cancer Outpatient Clinic Central venous catheter: Peripherally inserted central catheter

REMOVAL OF A PICC. Possible Cause Nursing Actions Prevention

Clinical Guideline for: Aseptic Technique

Care of your central venous catheter A guide for patients and their carers. We care, we discover, we teach

Guidelines for Transport of the Critically Ill

Managing Your Non-Tunneled (Percutaneous) Catheter: PICC, SICC, and JCC. What is a PICC catheter?

PATIENT URINARY CATHETER PASSPORT

Patient Information:

Laparoscopic Colectomy. What do I need to know about my laparoscopic colorectal surgery?

Indwelling urinary catheter. Information for patients and carers. RDaSH. Doncaster Community Integrated Services

Bladder Catheterization

TRANSPORT OF CRITICALLY ILL PATIENTS

Paediatric Intensive Care Unit Nursing Guideline: Chest Drains

3100B Clinical Training Program. 3100B HFOV VIASYS Healthcare

Aspira* Pleural Drainage Catheter

CHAPTER 1: THE LUNGS AND RESPIRATORY SYSTEM

404 Section 5 Shock and Resuscitation. Scene Size-up. Primary Assessment. History Taking

Emergency Insertion of Temporary Trans-venous Pacing Catheter in ICU

ACI UROLOGY NETWORK - NURSING BLADDER IRRIGATION GUIDELINES

PLEUR EVAC CHEST DRAINAGE SYSTEMS. Great Innovations to Enhance Chest Drainage

Levels of Critical Care for Adult Patients

Section 6: Your Hemodialysis Catheter

Laparoscopic Cholecystectomy

GOING HOME AFTER YOUR TAVR PROCEDURE

St. Louis Eye Care Specialists, LLC Andrew N. Blatt, MD

Home Care for Your Wound Drain

After care following insertion of a suprapubic catheter

Children's Medical Services (CMS) Regional Perinatal Intensive Care Center (RPICC) Neonatal Extracorporeal Life Support (ECLS) Centers Questionnaire

Vaxcel PICCs Valved and Non-Valved. A Patient s Guide

Location: Clinical Practice Manual

Administration of Medications & Fluids via a Peripheral Intravenous Cannula

INTRAPERITONEAL HYPERTHERMIC CHEMOTHERAPY (IPHC) FOR PERITONEAL CARCINOMATOSIS AND MALIGNANT ASCITES. INFORMATION FOR PATIENTS AND FAMILY MEMBERS

Peripherally Inserted Central Catheter (PICC)

Peripherally Inserted Central Catheter (PICC) for Outpatient

Infection Prevention & Control Team. Your urinary catheter & how to care for it / Patient Information Leaflet

TRACHEOSTOMY TUBE PARTS

INTERNATIONAL TRAUMA LIFE SUPPORT

Oxygen Therapy. Oxygen therapy quick guide V3 July 2012.

Section Two: Arterial Pressure Monitoring

Forced vital capacity: maximal volume of air exhaled with maximally forced effort from a maximal inspiration.

MANITOBA PATIENT SERVICE CENTRE STANDARDS

ORAL ANTICOAGULANTS RIVAROXABAN (XARELTO) FOR PULMONARY EMBOLISM (PE)

Transcription:

Nursing Procedure: Underwater seal chest drainage in the Highly Dependent or Critically Ill Infant or Child 2. The nurses role in ongoing chest drain management Lead Manager: Ms. Elaine Johnstone, Lead Nurse Responsible Director: Dr Neil Spenceley, Clinical Director, Critical Care Author(s): Jeanette Grady, Clinical Nurse Educator, Critical Care Approved by: PICU/HDU Clinical Guideline Group Date approved: September 2013 Date for Review: September 2015 Replaces previous version: June 2011 Chest Drain Ongoing Management Version: 2.0 Page 1 of 10

1. Introduction Chest drains and chest drainage systems are used frequently in the paediatric intensive care unit. There are many reasons for chest drain insertion but primarily they are used whenever there are specific conditions that interfere with the normal mechanism of lung expansion and altered intrathoracic pressures. Pleural chest tubes are inserted to evacuate blood, pus, air and fluid, from the thoracic cavity, to re-establish negative pressure in the intra pleural space and thereby expand the lungs following collapse resulting from surgery or trauma. Mediastinal chest tubes are placed in the mediastinum following open heart surgery, via a medial sternotomy in order to prevent accumulation of blood and clots around the heart, which could cause cardiac tamponade a life threatening situation. There are many different types of chest drains available including one-way flutter valve drains such as the Heimlich device or portable drains. However, for the majority of patients in the paediatric intensive care and high dependency units an underwater seal chest drainage system will be used. These systems provide an underwater seal, fluid collection chamber and suction chamber. In paediatric intensive care and high dependency, it is the bed side nurses role to ensure the patient is cared for safely once chest drains have been inserted. Although insertion of a chest drain may be necessary to help restore adequate oxygenation and promote lung re-expansion in the patient, there are potential risks and complications that the nurse must be aware of. This guideline is intended as a resource for staff involved in caring for childen in the Paediatric Intensive care and High Dependency units that require an underwater seal chest drain in situ. The guideline has been constructed after literature search and review of sourced textbooks, national guidelines (N.I.C.E.), Medline and CINHAL, and external nurse expert peer review and opinion. Further information on chest drainage in: Tutorial Notes-Chest Drainage Maxwell (unpublished 2008, reviewed 2010) and additional chest drain system resource at: www.atriummed.com/ See also recommendations and further information at end of this guideline. 2. Scope This nursing procedural guideline is intended to be followed by nurses involved in caring for the highly dependent or critically ill infant or child requiring underwater seal chest drainage within the Paediatric Intensive Care and High Dependency Units at R.H.S.C. Yorkhill. 3. Roles and responsibilities All nursing staff involved in caring for infants or children requiring underwater seal chest drainage in Paediatric Intensive care and High Dependency should be familiar with this nursing procedural guideline. Chest Drain Ongoing Management Version: 2.0 Page 2 of 10

4. BODY OF POLICY OR PROCEDURE Equipment : Available for ongoing management or in case of any untoward event* (*separate guideline) Fig. 1. Bed side equipment Available at bed side: Clamps (x1 each drain) Suction tubing-if required Suitable dressing (for ongoing site care) Sterile scissors Disposable apron Disposable gloves Wall suction gauge-if required (low flow *See Fig. 2) Occlusive dressing (E.g. sterile swabs) Tape (to secure occlusive dressing) Sterile gloves Sterile water Chlorhexidine 2% & 70% alcohol (swab suitable for urgent event) On chest drain trolley: Chest drain unit Fig. 2. *Low flow suction unit Chest Drain Ongoing Management Version: 2.0 Page 3 of 10

PROCEDURE Vital signs & patient observations: The infant or child with a chest drain(s) in situ must have the following observations monitored frequently & documented: Respiratory rate, effort & work of breathing Air entries Heart rate & pulse Oxygen saturations (SpO2) Blood pressure Temperature If a suitable invasive monitoring line is in situ then regular arterial or venous blood gases should be done. Chest drain site care: the nurse must ensure the drain site is checked regularly for the following: Drain is properly anchored with appropriate suture(s) and secured to child s chest wall Drain site is dry, clean & covered with dry non-adherent dressing Drain site dressing should be inspected for signs of leakage or odour Area around drain site inspected for signs of leakage, inflammation, infection or subcutaneous emphysema RATIONALE Frequent monitoring of vital signs is important in detecting any alterations from previously documented normal values as these may indicate problems such as haemorrhage, unresolved pneumothorax, tension pneumothorax, sepsis, infection and ventilation-perfusion mismatch. Suggestions for monitoring vital signs ranges from ¼ hourly immediately post drain insertion/admission, to ½ hourly to hourly whilst drain is in situ. The frequency of monitoring specific vital signs and blood gas analysis will be determined by the child s clinical status with any deterioration in the child s vital signs being reported to the nurse-incharge and medical team immediately. The drain must be well secured after insertion to prevent it becoming dislodged, slipping or falling out. Large amounts of tape and padding may restrict chest movement and prevent regular inspection of the drain site for complications. A dry non-adherent dressing, non-occlusive is most suitable. The drain site and dressing should be reviewed daily and the dressing should not need redressed for 2-3 days unless leakage apparent. Chest drainage unit (CDU) care: the nurse must check the under water seal chest drainage system frequently to ensure it is working correctly and to avoid potential problems: *see Fig. 5 Any signs of complications such as infection should be documented and reported and appropriate action taken. E.g. wound swab or medical team review. Chest Drain Ongoing Management Version: 2.0 Page 4 of 10

Keep chest drainage system and tubing below the level of the patients chest Perform initial inspection of connections & tubing. Thereafter inspect CDU tubing & drain connections regularly (suggested hourly) and keep tubing free from bed-sides/cotsides Ensure tubing & drain(s) are secure but not pulling. Try not to secure tubing to child s bed, linen or loose clothing (Fig. 3) Aim to lay tubing horizontally across bed before dropping it vertically into drainage system to facilitate drainage avoid dependent loops or kinking of tubing (Fig. 4) Ensure chest drainage unit is secured upright on floor beside or at the end of the bed/cot. Check water seal chamber (B)* maintained at 2cm level The chest drainage system must always be kept below the level of the child s chest to prevent fluid re-entering the pleural space syphonage. Regular inspection of the drain and tubing is vital to ensure that the system is still intact the drain has not slipped, connections have not come loose or tubing has become kinked. Securing tubing to clothing or bedding is not advised as sudden movements by the child or change of bed-linen could dislodge the drain. Dependent loops or kinking of tubing can impede drainage, block tubing and cause high pressures at chest tube and drainage tube connections, potentially resulting in clinical complications such as tension pneumothorax. Securing the drainage system to the floor with tape may be necessary to prevent tipping of system. Water in the water seal chamber (B)* can evaporate and under water seal will be lost. The level must be checked regularly and topped-up as per manufacturers instructions. Monitor and record any bubbling or swinging in the water seal chamber of the CDU. Report any changes to nurse-in-charge. If chest drain in pleural cavity, observe and record any fluctuations in water seal level of CDU with respiratory effort/ventilation tidalling Ensure suction chamber (A)* filled to -20cmH2O level in CDU. Persistent bubbling may suggest visceral pleural air leak, a drain on suction that has one of the drain eyelets open to air or with mediastinal drains patient with open chest. Swinging of the water seal level with respirations indicates drain patency and confirms drain position in pleural cavity. If suction is required, a low pressure system must be used as excessive Chest Drain Ongoing Management Version: 2.0 Page 5 of 10

If suction required - Check suction tubing connected to low flow regulated suction & suction control stopcock at CDU switched on. Check negative pressure on suction is set low enough to give gentle bubbling in the suction chamber no excessive bubbling Ensure suction filter attached changed when indicated Check fluid collection chamber (D)* frequently (15 min. intervals to 30min., then hourly) and document volume, type and colour of drainage. E.g. fresh blood, serous, cloudy. Always label chest drain(s) and drainage units clearly. E.g. Left pleural 1 or Right mediastinal 2. Specific nursing care issues: The nurse should assess the child s level of pain or discomfort regularly and administer analgesia as prescribed Reposition the child regularly as tolerated ensuring drain and tubing secure throughout a two nurse procedure. negative pressures may cause perpetuation of air leaks. If suction is required for more than one chest drain then a separate suction unit is advised for each chest drain. Turbulent bubbling is unnecessary, will not improve fluid drainage and will result in increased evaporation of water in the chamber. Frequent assessing and documenting of fluid volume and type drained and from what site is essential, as this may help the nurse determine if the child has any of the following: Persistent or fresh bleeding Infection Chylothorax Tamponade Frequency of checking tubing and drainage will range from every 15 minutes initially (for first 6 hours) post admission from cardiac or thoracic surgery, to 30 minutes (6 hours) then hourly once child stabilised. This is provided there is no other evidence or suspicion of bleeding or tamponade present. Pain from having a chest drain in situ can inhibit the child s movement and breathing which can slow their recovery. Therefore, regular pain assessment is vital to ensure the child receives adequate analgesia while the drain is in situ. Repositioning and improving mobility can facilitate drainage, aid breathing and lung expansion and reduce complications associated with immobility. Repositioning the infant/child with a chest drain in situ should involve at least two nurses in order to prevent accidental disconnection or kinking of drain and/or Chest Drain Ongoing Management Version: 2.0 Page 6 of 10

Avoid excessive chest tube handling/manipulation such as milking or stripping unless specifically instructed. (see Chest Drainage tutorial book for more details) Avoid routine clamping of chest drain tube unless specifically instructed by senior physician (see Chest Drainage tutorial book for more details) Fig. 3 Tubing secure tubing. Routine manipulation of chest drain tubing by milking or stripping the tubing has been common practice in the past in an attempt to prevent mediastinal drains from blocking with clots and causing cardiac tamponade. However, this type of tubing manipulation is thought to cause significant increases in negative intrathoracic pressures, may not be of proven benefit and may cause tissue damage. Routine clamping of chest drains is not recommended especially if bubbling, as it prevents the escape of air or fluid from the chest or mediastinum, leading to an increased risk of tension pnuemothorax or cardiac tamponade. Fig. 4 Avoid dependent loops FURTHER INFORMATION AND RECOMMENDATIONS: Practical chest drainage system issues: When there is no air leak, the water level in the water seal chamber should rise and fall with the patient's respirations, reflecting normal pressure changes in the pleural cavity during respiration. During spontaneous respirations, the water level should rise during inhalation and fall during exhalation. If the patient is receiving positive pressure ventilation, the oscillation will be just the opposite. Oscillations may be absent if the lung is fully expanded and suction has drawn the lung up against the holes in the chest tubes. Chest Drain Ongoing Management Version: 2.0 Page 7 of 10

A patient with only mediastinal tubes (and a closed chest) should have no bubbling or fluctuations in the water seal chamber, since these tubes are not in contact with the pleural cavity. As one of the risks of accumulation of fluid, blood or clots around the heart is cardiac tamponade, it is particularly important for nurses caring for patients with mediastinal chest tubes to be watchful for signs of cardiac tamponade with special attention paid to the drainage collection chamber. Fig. 5. Underwater seal chest drainage unit Suction chamber(a) Underwater seal chamber(b) Collection chamber(d) 5. Review This nursing procedural guideline should be reviewed every two years from date of approval. 6. References Allibone, L (2003) Nursing Management of chest drains. Nursing Standard, Vol.12 (17), pp 45-54. Allibone, L (2005) Principles for inserting and managing chest drains. Nursing Times, Vol. 101 (42), pp45-48. Atrium (2012) A personal guide to managing chest drainage. Available from: http://www.atriummed.com/en/chest_drainage/documents/bluehandbook342263l.pdf Chest Drain Ongoing Management Version: 2.0 Page 8 of 10

Balfour-Lynn, IM Abrahamson, E Cohen, G Hartley, J King, S Parikh, D Spencer, D Thomson, AH Urquhart, D (2005) Draft - BTS guidelines for the management of pleural infection in children. Thorax, Vol. 60, Suppl.I, pp. i1-i21. Bar-El, Y Ross, A Kablawi, A Egenburg, S (2001) Potentially dangerous negative pressures generated by ordinary pleural drainage systems. Chest, Vol. 119 (2), pp 511-514. Briggs, D (2010) Nursing care and management of patients with intrapleural drains. Nursing Standard, Vol. 24 (21), pp. 47-55. Coughlin, AM Parchinsky, C (2006) Go with the flow of chest tube therapy. Nursing, Vol. 36 (3), pp 36-41. Crawford, D (2011) Care and management of a child with a chest drain. Nursing Children and Young People, Vol.23 (10), pp.27-33. Day, TG Perring, RR Gofton, K (2008) Is manipulation of mediastinal chest drains useful or harmful after cardiac surgery? Interactive Cardiovascular and Thoracic Surgery, Vil. 7, pp 888-890. Duncan, C Erikson R (1982) Pressures associated with chest tube stripping. Heart and Lung, Vol. 11 (2), pp. 166-171. Halm. MA (2007) To strip or not to strip? Physiological effects of chest tube manipulation. American Journal of Critical Care, Vol. 16 (6), pp. 609-612. Havelock, T Teoh, R Laws, D Gleeson, F (2010) British Thoracic Society Pleural Disease Guideline: Pleural procedures and thoracic ultrasound. Thorax, Vol. 65, (Suppl. 2): ii.61 76. Horrox, F (2002) Chest drain management. In: Manual of Neonatal & Paediatric Heart Disease, Whurr, London. Scmelz, JO Johnson, D Norton, JM Andrews, M Gordon, PA (1999) Effects of position of chest drainage tube on volume drained and pressure. American Journal of Critical Care, Vol. 8 (5), pp. 319-323. Sullivan, B (2008) Nursing management of patients with a chest drain. British Journal of Nursing, Vol. 17 (6), pp 388-393. Wallen, M Morrison, A Gillies, D O Riordan, E Bridge, C Stoddart, F (2002) Mediastinal chest drain clearance for cardiac surgery. Cochrane Database of Systematic Reviews, Issue 2, CD003042. Chest Drain Ongoing Management Version: 2.0 Page 9 of 10

A Communication and Implementation Plan R.H.S.C. Nursing Policy Group PICU/HDU Clinical Guidelines group PICU/HDU Lead Nurse PICU/HDU ANP s, Band 7 and Band 6 senior nursing staff and nursing teams PICU/HDU Lead Consultant PICU/HDU Consultants and junior medical staff B Monitoring Compliance monitored by Lead nurse, ANP s and Senior clinical nurses in PICU/HDU. Datix and critical incident reporting of adverse events or incidents C Impact Assessment EQIA not relevant to this nursing procedural guideline as there are no discriminatory practices identified in implementing this guideline. Chest Drain Ongoing Management Version: 2.0 Page 10 of 10