LevelOne User Manual VDS-0120 Ethernet over VDSL2 Converter (PSE)



Similar documents
Ethernet over VDSL2 PoE PD Converter

VDSL2 LAN Extender User Manual

V101. VDSL LAN Extender

SHDSL LAN EXTENDER H301A. User Manual

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

Long Range Ethernet Extender

Ethernet over VDSL2 Converter VC-201A / VC-204

VDSL Ethernet LAN Extender

4-Port 10/100Base-TX with PoE + 1-Port BNC / RJ-11 Industrial Ethernet Extender

IEX-402-SHDSL Series Quick Configuration Guide First Edition, January 2013

Extending Ethernet over 2-wire Copper Networks

DES-1005P 5-Port 10/100Mbps with 1-Port PoE Unmanaged Switch

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Detecting Bridged Tap and Noise Interference in VDSL2 Access Networks using the JDSU SmartClass TPS

Provides one channel for Ethernet over existing

8-Port PoE Network Switch

Power over Ethernet (PoE)

VDSL Ethernet Extender AT-MC605. Installation Guide Rev. C

SOHOware Long Reach Ethernet (LRE) Solution

Digital Subscriber Line (DSL) Transmission Methods

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

VDSL2 A feasible Solution for Last Mile

Provides one channel for Ethernet over existing

TELECOMMUNICATIONS STANDARDS ADVISORY COMMITTEE TSAC WORKING GROUP ON NEW STANDARDS AND POLICY (NSP)

Black Box Explains: DSL

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Long Reach PoE over Coaxial Extender Kit

Fiber Optic Connectivity SECURITY SURVEILLANCE SOLUTIONS. ComNet Managed Ethernet Switches

FSW-0505TX/0805TX 5/8 Port SOHO 10/100Mbps NWay Switch FSW-0505TX FSW-0805TX. 5/8 Port SOHO 10/100Mbps NWay Switch. User s Manual. (Revision 1.

T1 Networking Made Easy

FlexPoint T1/E1 Copper to Fiber Line Driver

Intel System Engineers Documents. DSL General Overview

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

TELECOMMUNICATIONS STANDARDS ADVISORY COMMITTEE WORKING GROUP ON COMMON CONNECTION STANDARDS (CCS)

MDI/MDIX) FEP-32008T-3

8 Port Gigabit 10M/100M/1000M Fast Ethernet Switch. User Manual

Copper to Fiber Stand-Alone Media Converter. Quick Installation Guide

Elisa Carrier Services. Elisa Operator Broadband Services. Technologies, distribution centres and delivery interfaces

LevelOne User Manual. HVE-6501T/6501R HDMI over IP PoE Transmitter/Receiver. Ver 1.0

Gigabit Switching Ethernet Media Converters - Product User Guide

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Public Switched Telephone System

Acterna DSL Services Tester TPI 350+ Application Highlights

ADSL MODEM. User Manual V1.0

FILTERING/FORWARDING RATES 100Mbps port - 148,800pps 10Mbps port - 14,880pps. TRANSMISSION MEDIA 10BaseT Cat. 3, 4, 5 UTP/STP 100BaseTX Cat.

V-DSL technology in the NBN

IFS SP-PoE Splitter User Manual

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

Setup guide. point to point wall plate extenders

How DSL Works. by Curt Franklin

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Characterization of a new copper cable for next generation DSL systems

Model CFA-24 Transparent Cable Farm Automation Switch

PoE+ Extender Switch User's Manual. Rev W

Adaptive Spectrum and Signal Alignment, Incorporated THE RE-PROFILER DSM CLOSES THE CASE ON DIAGNOSING DSL/VDSL TROUBLES

MOTOROLA CANOPY WIRELESS BROADBAND INTERNET ACCESS PLATFORM

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

Reverse Powering Its Benefits and Constraints Daniel Feldman VP Business Development, Microsemi. Power Matters

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

Evolution from Voiceband to Broadband Internet Access

Perle 10/100 Ethernet Media Converters

XDSL and DSLAM Access Technologies

LevelOne VOI H.323 VoIP Gatekeeper. User Manual

HDMI / Video Wall over IP Transmitter with PoE

HARTING econ 3000 Introduction and features

Cisco G.SHDSL High Speed WAN interface Card with IEEE 802.3ah EFM Support for Cisco Integrated Services Routers

Digital Subscriber Line (DSL)

Terminal and Dimension

IP DSLAM IDL Quick Installation Guide

LevelOne. HDMI Video Wall over IP PoE Transmitter / Receiver. Quick Installation Guide HVE-6501R: HVE-6601R:

MICROSENS Media Converter 10/100/1000T to Gigabit Fiber

Safety Warnings and Guidelines

Quick Installation Guide 8-Port 10/100/1000Mbps Green Switch

500M Powerline Pass-Through Ethernet Bridge

Speed-DSL 9.2 Ethernet connection over 8-wires up to 9.2 Mbit/s. Manual * * * *

24-Port VDSL2/ADSL2+ with 2-Port Gigabit TP/SFP Combo IP DSLAM

CONTRIBUTION ABSTRACT

Network Neutrality Statement

HDMI over IP Broadcasting System ITEM NO.: HE05BT, HE05BER HDMI Matrix over IP Broadcasting

SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s. Manual

Carrier Ethernet: New Game Plan for Media Converters

Broadband 101: Installation and Testing

GEU Port Gigabit Switch

BEC 6200WZL. 4G/LTE Cellular Broadband Router. Quick Start Guide

Network Requirements for DSL systems, (ADSL through G.Fast) (A summarized view)

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature

Loop-IP6702 TDMoEthernet

How Enhanced DSL Technologies Optimize the Last Copper Mile By John Williams

Profitably Get High Speed, Reliable CE 2.0 Services Out to Small and Medium Business Using EFM over Copper

IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual

EAGLE Power over Ethernet Products for IP Powering Applications. Flexibility, Simplicity and Value LAN POWER SYSTEMS. Trend Datacom USA, Inc.

DSL Variations. NEXTEP Broadband White Paper. Broadband Networks Group. Definitions and differences of Digital Subscriber Line variations.

What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France

Ethernet over Copper Transmission Extenders. Ethernet Transmission over Coaxial or UTP Cable. Fiber Optic and Ethernet Network Solutions

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

Product Specifications

Security & Surveillance Cabling Systems

Transcription:

LevelOne User Manual VDS-0120 Ethernet over VDSL2 Converter (PSE) V1.0 1

Table of Content 1. Introductions... 3 2. Application Notes... 3 3. Features... 4 4. Packing Contents... 4 5. LED Indicators... 5 6. Dip Switches Settings... 5 7. Data Rates & Distances... 7 2

1. Introductions The VDS-0120, a VDSL2 (Very high-bit-rate Digital Subscriber Line) PSE LAN Extender, provides a broadband transmission up to 100/60Mbps of downstream/upstream data rate over single pair copper line for point-to-point Ethernet connectivity. With 100/60Mbps data rate, VDS-0120 supports transmission distance up to 300 meters, and 30/10 Mbps for 1km long range connection. Users may also select a fixed data rate or a fixed SNR margin for different copper line ranging. With Power Sourcing Equipment, VDS-0120 provides power supply over Ethernet cable to the 802.3af compliant power device. With plug and play features and minimum installation time, each VDS-0120 can be configured into either CO for central side or RT for remote side by dip switch setting. The VDS-0120 conforms to the ITU-T G.993.1 and G.993.2 to meet VDSL/VDSL2 and SG15Q4 DMT for network requirements. A pair of VDS-102 and VDS-0120 offers a cost effective solution for bandwidth-hungry applications such as LAN-to-LAN connectivity, Video Streaming, FTTB, and MDU/MTU over single twisted pair telephone line. 2. Application Notes 1) Ethernet To Ethernet Bridge Extension VDS-0200 VDS-0120 0 3

3. Features ITU-T G.993.1, G.993.2 VDSL/VDSL2 and SG15Q4 DMT Compliance 100/60Mbps DownSream/UpStream for distance up to 300 meters Supports VDSL2 connection up to 2000 meters IEEE802.3af compliant -48V Power-Sourcing-Ethernet (PSE) standard Minimum 15.4Watt for Class 3 output power RJ11 for DSL interfaces + RJ45 for Ethernet LAN port Five LED Indicators 4 Dip Switches for Configuration Settings Trellis Coding support up to 1024 Discrete Multi-Tone (DMT) bins Auto MDIX for 10/100 BaseT Ethernet LAN Ports Low-Latency for Video/Voice/Data applications Line Surge Protection Selectable Fast and Interleaved modes Fast mode guarantees a minimum end to end latency less than 1 ms. Interleaved mode provides impulse noises protection for any impulse noise with a duration less than 250 us. Interleaved mode has a maximum end to end latency of 10 ms. Interleaved mode is the default mode. Selectable fixed data rate and fixed SNR margin User may select fixed SNR margin (9 db) or fixed target data rate. When fixed SNR margin is selected, the systems will maintain the SNR margin at 9 db across all available loop length. When fixed target data rate is selected, the system will lock the data rate at 50/20Mbps whenever the calculated SNR margin is higher than 9 db. This will result in the best system stability and is the default mode. 4. Packing Contents Inside the package you should find: (1) One VDS-0120 VDSL2 PSE LAN Extender (2) One AC to DC Power Adaptor (DC12V/2.5A) (3) One User Manual CD Please check if the packing is damaged or any component is missing. If so, please contact your distributor. 4

5. LED Indicators On the front panel of VDS-0120, there are four LED indicators as the following VDS-0120 Front Panel VDS-0120 Rear Panel POWER: Green On indicates power is on and normal. LAN: DSL: M/S: PSE: Green On indicates Ethernet LAN port is in connection. Flashing indicates Ethernet LAN data activities. Green On indicates VDSL2 is in connection. Flashing indicates VDSL2 is in line handshaking. Green On indicates VDS-0120 is set as Slave (VTU-R) mode. OFF indicates VDS-0120 is set as Master (VTU-C) mode. Green On indicates VDS-0120 is providing power over Ethernet. OFF indicates the Power Sourcing Equipment is OFF. 6. Dip Switches Settings Pin 1 Pin 2 Pin 3 Pin 4 VTU-C/R Mode Rate Limit SNR OFF VTU-C Interleaved 50/20 Mbps 9dB ON VTU-R Fast Full Rate 6dB 5

Pin 1: VTU-C/R Switch VTU-C: VDS-0120 will act as at the Central Office (CO) side. VTU-R: VDS-0120 will act as at the Customer Premise Equipment (CPE) or Remote side. Pin 2: Mode for impulse noise protection Interleave mode: Protection for up to 250ms impulse noises with latency less than 6 ms. Fast mode: Direct data transmission with latency less than 1ms. Pin 3: Rate limit control 50/20 Mbps: Line rate limited to 50/20 Mbps. Full Rate: Provides up to 100Mbps/60Mbps line rate in short line. Pin 4: Signal to Noise Ratio (SNR) 9dB: Higher SNR margin (9dB) will result in less error with more stable VDSL2 link. 6dB: Original and Normal channel noise protection with 6 db SNR. 6

7. Data Rates & Distances Performance in AWG 26 Line at 6dB with full rate Down Stream Data Rate (Mbps) Up Stream Data Rate (Mbps) Distance (feet) 100 60 500 98 53 1000 90 44 1250 80 36 1500 70 27 1750 60 18 2000 48 11 2500 39 8 3000 35 3.5 3500 28 0.3 4000 7