LENOVO EMC VNX5150 STORAGE ARRAY SPECIFICATIONS

Similar documents
EMC VNX SERIES UNIFIED STORAGE SYSTEMS

EMC VNX5500-F UNIFIED STORAGE FLASH ARRAY

VNX Physical Specifications

EMC VNXe3150, VNXe3300 UNIFIED STORAGE SYSTEMS

EMC VNX SERIES DC POWERED UNIFIED STORAGE SYSTEMS

EMC VNX SERIES UNIFIED STORAGE SYSTEMS

EMC SYMMETRIX VMAX 10K

EMC VNXe3200 UNIFIED STORAGE SYSTEM

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

EMC VMAX3 FAMILY - VMAX 100K, 200K, 400K

EMC VMAX3 FAMILY VMAX 100K, 200K, 400K

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

Data Sheet Fujitsu ETERNUS DX200 S3 Disk Storage System

EMC VNX VG8 GATEWAY. Specifications ARCHITECTURE

EMC SYMMETRIX VMAX 20K STORAGE SYSTEM

Data Sheet FUJITSU Storage ETERNUS DX200F All Flash Array

EMC CLARiiON AX150/AX150i

Data Sheet FUJITSU Storage ETERNUS DX500 S3 Disk System

EMC VNX VG2 GATEWAY. Specifications ARCHITECTURE

Virtualizing SQL Server 2008 Using EMC VNX Series and Microsoft Windows Server 2008 R2 Hyper-V. Reference Architecture

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

Data Sheet FUJITSU Storage ETERNUS DX100 S3 Disk System

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

Data Sheet FUJITSU Storage ETERNUS DX100 S3 Disk System

Data Sheet FUJITSU Storage ETERNUS DX200F All-Flash-Array

Data Sheet Fujitsu ETERNUS DX500 S3 Disk Storage System

EMC CLARiiON AX4 Storage System

UNIFIED HYBRID STORAGE. Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment

How To Backup To Disk With Deduplication On An Fujitsu Ecson Cser800 S4 Data Protection Appliance

How To Use An Fujitsu Ces800 S5 Backup Appliance

Data Sheet FUJITSU Storage ETERNUS CS800 S5

Data Sheet Fujitsu ETERNUS CS800 S4

EMC VNX FAMILY. Copyright 2011 EMC Corporation. All rights reserved.

Cisco 7816-I5 Media Convergence Server

Introduction to the EMC VNX2 Series

DATASHEET FUJITSU ETERNUS CS800 DATA PROTECTION APPLIANCE

Data Sheet FUJITSU Storage ETERNUS CS800 S6

EMC ISILON HD-SERIES. Specifications. EMC Isilon HD400 ARCHITECTURE

EMC ISILON NL-SERIES. Specifications. EMC Isilon NL400. EMC Isilon NL410 ARCHITECTURE

Symantec NetBackup 5000 Appliance Series

Application Server V240 Platform

Data Sheet FUJITSU Storage ETERNUS LT260 Tape System

K2 LxO RAID Storage Systems

Storage System. Planning Checklist. EC E1, First Edition

Overland 2 TB SnapServer 210 NAS Server. Overland 4 TB SnapServer 210 NAS Server Operating System GuardianOS GuardianOS

STORAGETEK 2540 ARRAY

INTRODUCTION TO THE EMC VNX SERIES

Cisco Wide Area Application Services (WAAS) Appliances

HUS-IPS-5100S(D)-E (v.4.2)

Scout 1U Rackmount Computer

Enterprise Switches. Accelar 8000

Symantec NetBackup 5220

HITACHI VIRTUAL STORAGE PLATFORM FAMILY MATRIX

SUN DUAL PORT 10GBase-T ETHERNET NETWORKING CARDS

EMC ISILON X-SERIES. Specifications. EMC Isilon X200. EMC Isilon X210. EMC Isilon X410 ARCHITECTURE

ORACLE EXALYTICS IN-MEMORY MACHINE X3-4

Security Information & Event Manager (SIEM)

HITACHI VIRTUAL STORAGE PLATFORM FAMILY MATRIX

Cisco WAE Deployed with Cisco ACNS: Product Function Matrix. Two 10/100/1000BASE-T. Two 10/100/1000BASE- T

DSA E-Series E2600, DE1600, DE6600. en Storage System Site Preparation Guide

EMC DATA DOMAIN DD990

Virtualizing SQL Server 2008 Using EMC VNX Series and Microsoft Windows Server 2008 R2 Hyper-V. Proven Solution Guide

Data Communications Hardware Data Communications Storage and Backup Data Communications Servers

CloudBridge. Deliver the mobile workspace effectively and efficiently over any network. CloudBridge features

Broadcom NetXtreme II Dual Port 10GBase-T Adapter for IBM System x enables 10GBase-T support for 10 Gb Ethernet solutions

G-TAP A Series // Data Sheet

VCE Vblock System 340 Gen 3.2 Architecture Overview

How To Build A Cisco Uniden Computing System

NetScaler SD-WAN. Securely delivers optimal application performance over any network

WAVE-574 Hardware Specifications

1. Specifiers may alternately wish to include this specification in the following sections:

Fujitsu PRIMERGY BX600 S3 Blade Server

Cisco-EMC Microsoft SQL Server Fast Track Warehouse 3.0 Enterprise Reference Configurations. Data Sheet

Cisco UCS B460 M4 Blade Server

MICROSOFT EXCHANGE SERVER 2010 PERFORMANCE REVIEW USING THE EMC VNX5300 UNIFIED STORAGE PLATFORM

Scalable. Reliable. Flexible. High Performance Architecture. Fault Tolerant System Design. Expansion Options for Unique Business Needs

DATASHEET FUJITSU ETERNUS LT250 TAPE LIBRARY

Scalable. Reliable. Flexible. High Performance Architecture. Fault Tolerant System Design. Expansion Options for Unique Business Needs

Data Sheet FUJITSU Storage ETERNUS LT20 S2 Tape System

MESOS CB220. Cluster-in-a-Box. Network Storage Appliance. A Simple and Smart Way to Converged Storage with QCT MESOS CB220

LaCie 12big Rack Network

Deliver More Applications for More Users

Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems

Vault 8000 Series. Product Overview KEY BENEFITS

Cisco UCS B-Series M2 Blade Servers

Benefits. Product Overview. There is nothing more important than our customers. DATASHEET

Technical White Paper ETERNUS DX8700 S2 Hardware Architecture

SUN SERVER X4-2L SYSTEM

Frequently Asked Questions: EMC UnityVSA

IBM TotalStorage Network Attached Storage 300G

How To Power A Power Supply Shelf With A Power Unit (Hp 2920)

Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server

XenData Product Brief: SX-250 Archive Server for LTO

Oracle FS1-2 Flash Storage System

Cisco Redundant Power System 2300

Cisco Unified IP Phone Power Injector

Security Information & Event Manager (SIEM)

Transcription:

LENOVO EMC VNX5150 STORAGE ARRAY SPECIFICATIONS Lenovo EMC VNX5150 storage systems deliver uncompromising scalability and flexibility for the mid-tier while providing market-leading simplicity and efficiency to imize total cost of ownership. ARCHITECTURE Based on the powerful Intel Xeon-5600 processor, the Lenovo EMC VNX5150 implements a modular architecture that integrates hardware components for block iscsi, Fibre Channel, and Fibre Channel Over Ethernet protocols. Storage is provided via dual storage processors leveraging both 2.5 and 3.5, near-line, and solid state drives. The system includes a disk processor enclosure, which holds the disk drives and processors, a standby power system, and disk array enclosure for additional disk storage.

VNX5150 PHYSICAL SPECIFICATIONS BLOCK COMPONENTS VNX5150 Min/Max s 4/125 Array Enclosure 3U Disk Processor Enclosure (Holds 15x3.5 or 25x2.5 / Flash drives) Enclosure Options (DAE) 25x2.5 /Flash drives 2 U 15x3.5 /Flash drives 3 U Standby Power System 1U 1.2KW Raid Options 0/1/10/3/5/6 CPU/Memory per Array Intel Xeon 5600 /16GB Max Block UltraFlex IO Modules per Array 4 Embedded IO Ports per Array 8 FC ports and 4 ports (2 BE buses)*** Max Total Ports per Array 24 2/4/8 Gb/s FC Max Ports per Array 16 1 GBaseT iscsi Max Total Ports per Array 1 8 10 GbE iscsi Max Total Ports per Array 1 8 Max FCoE Total Ports per Array 1 8 /s Buses (4 Lanes per Bus) for DAE Connections 2 Management LAN 2x 10/100/1000 Copper GbE FUNCTIONAL LIMITS VNX5150 Max Raw Capacity 480TB Max SAN Hosts 2,048 Max Number of Pools 20 Max Number of LUNs 2,048 Max LUN Size 16 TB (Virtual Pool) OS Support Block OS s see E-Lab Navigator Support Matrix on Powerlink VNX5150 CONNECTIVITY The VNX5150 provides flexible connectivity options via UltraFlex IO modules for block storage processors for FC and iscsi host connectivity (see above table for number of modules supported SP). UltraFlex IO Module Options (Block) IO MODULE Four-Port Fibre Channel Module Four-Port 1 Gb/s iscsi Module Two-Port 10 Gb/s Opt iscsi Module Two-Port 10 GBaseT iscsi Module Two-Port 10 GbE FCoE Module DESCRIPTION FC module with four ports auto-negotiating to 2/4/8 Gbps; uses optical SFP and OM2/OM3 cabling to connect directly to host HBA or FC switch iscsi module with four 1 GBaseT RJ-45 copper connections to Cat 6 cabling to Ethernet switch; includes TCP offload engine iscsi module with two 10 Gb/s Ethernet ports and choice of SFP+ optical connection or active Twinax copper connection to Ethernet switch; includes TCP offload engine iscsi module with two 10 GBaseT Ethernet ports with copper connection to Ethernet switch; includes TCP offload engine FCoE module with two 10 Gb/s Ethernet ports and choice of SFP+ optical connection or active Twinax copper connection to converged enhanced Ethernet switch 1 Option available

BACK-END (DISK) CONNECTIVITY The storage processor connects to one side of each of two redundant pairs of four-lane x /s Serial Attached SCSI () buses, providing continuous drive access to hosts in the event of a storage processor or bus fault. The VNX5150 requires a imum of four vault drives ( or Near-line ) and supports a maximum of 125 disks (see VNX5150 physical specifications table above). Approximately 200 GB per vault drive is consumed by VNX operating environment software and data structures. Disk s for 15 x 3.5 Disk Processor Enclosures/Disk Array Enclosure Noal Capacity Supported in 15 drive DAE Formatted Capacity* Form Factor 100GB Solid State 200GB Solid State 300GB 15K 600GB 15K 600GB 10K 900GB 10K 1TB 7.2K 2TB 7.2K 3TB 4TB 7.2K 7.2K 93.1 GB 186.31 272.59 545.19 545.19 820.60 926.04 1,852.09 2,794.50 GB GB GB GB GB GB GB GB 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 Height 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Rotational Solid Solid 15,000 15,000 10,000 10,000 7,200 7,200 7,200 7,200 Speed State State rpm rpm rpm rpm rpm rpm rpm rpm 3,726 GB Interface Data Buffer N/A SSD N/A SSD Access Time Average Read N/A N/A 3.4 3.4 3.7 3.7 8.5 8.5 8.5 8.5 Average Write N/A N/A 3.9 3.9 4.2 4.2 9.5 9.5 9.5 9.5 Rotation Latency N/A N/A 2.0 2.0 3.0 3.0 4.16 4.16 4.16 4.16 Noal Power Consumption (Watts) Operating 4.97 4.97 12.92 16.35 5.6 5.6 12.2 12.2 12.2 12.2 Mode Idle Mode 1.36 1.36 8.74 11.68 3.1 3.1 8.0 8.0 8.0 8.0

Disk s for 25 x 2.5 Disk Processor Enclosures/Disk Array Enclosure Noal Capacity 100 GB Solid State 200 GB Solid State 300 GB 10K 600 GB 10K 900 GB 10K Formatted Capacity 93.1 GB 186.31 GB 272.59 GB 545.19 GB 820.6 GB Form Factor 2.5 2.5 2.5 2.5 2.5 Height 1.0 1.0 1.0 1.0 1.0 Rotational Speed Solid State Solid State 10,000 rpm 10,000 rpm 10,000 rpm Interface Data Buffer N/A SSD N/A SSD Access Time Average Read N/A N/A 3.6 3.6 3.6 Average Write N/A N/A 4.2 4.2 4.2 Rotation Latency N/A N/A 3.0 3.0 3.0 Noal Power Consumption (Watts) Operating Mode 4.97 4.97 6.15 5.6 5.6 Idle Mode 1.36 1.36 3.5 3.1 3.1 Disk Array Enclosures 15 x 3.5 DAE 25 x 2.5 DAE Types Supported 3.5 Flash 3.5 15K Rotating 2.5 Flash 2.5 10K Rotating 3.5 10K Rotating 3.5 7.2K Rotating Mixing No limitations No limitations Controller Interface VNX5150 SOFTWARE FACILITIES The VNX5150 offers advanced features available via various software suites and packs. VNX5150 Software Optimize performance and cost concurrently with Dynamic tiering of data across drives Extendable cache for performance boost Management Protocols Base Software (included with VNX OE) FAST Suite: Automatically optimize for the highest system performance and the lowest storage cost simultaneously Security and Compliance Suite: Keep data safe from changes, deletions, and malicious activity Unisphere for Block iscsi, FC and FOCE included EMC Virtual Provisioning Extendable cache for performance boost Trend analysis and reporting Monitor and achieve performance objectives Encrypt data where it is created

Local Protection Suite: Practice Safe Data Protection and Repurposing Remote Protection Suite: Protect data against localized failures, outages, and disasters Application Protection Suite: Automate application copies and prove compliance Protection Pack Total Value Pack Block storage snaps and clones Continuous Data Protection for DVR-like recovery for block storage Storage replication with DVR-like recovery Integrated WAN deduplication and bandwidth reduction Application copy management Prove protection compliance Local Protection Suite Remote Protection Suite Application Protection Suite Security & Compliance Suite Local Protection Suite Remote Protection Suite Application Protection Suite FAST Suite ADDITIONAL OPTIONAL EMC TITLES EMC PowerPath : path management VNX5150 ELECTRICAL SPECIFICATIONS NOTE: Each DPE requires a Standby Power Supply (see the following information) VNX5150 DPE (15 x 3.5 drives) VNX5150 DPE (25 x 2.5 drives) DIMENSIONS Height (in/cm) 5.25 in/ 13.34 cm 5.25 in/ 13.34 cm Width (in/cm) 17.5 in/ 44.45 cm 17.5 in/ 44.45 cm Depth (in/cm) 24.25 in/ 61.6 cm 24.25 in/ 61.6 cm Weight (lb/kg) (with and without drives) Full: 96.8/44.0 Empty: 61.8/28.1 Full: 75.25/34.2 Empty: 59.0/26.8 Standby Power Supply Power AC Line Voltage AC Line Current, Internal and Pass-through Internal Power Consumption Power Factor Heat Dissipation In-rush Current AC Protection AC Inlet Type AC Outlet Type Charge Times 1.2KW Standby Power Supply 100 to 240 Vac ± 10%, single-phase, 47 to 63 Hz 0.10 A max at 100 Vac, internal power consumption (up to 10 A max at 100 Vac, pass-through to AC outlets) 0.05 A max at 200 Vac, internal power consumption (up to 6 A max at 200 Vac, pass-through to AC outlets) 70 VA (40 W) pk in hi-charge mode, 10 VA (6 W) in float charge mode N/A for pass-through load, internal 10 VA load is 0.60 power factor 21.6 x 103 J/hr, (20 Btu/hr) steady state 9 A max for ½ line cycle, per power supply at 240 Vac 15 A fuse, both phases IEC320-C14 appliance coupler with switch IEC320-C13 appliance coupler, quantity two 190 utes max

Power 1.2KW Standby Power Supply AC Failure Detect Time 10 ms max Transfer Time 25 ms max Dimensions (HxWxL) 4.0 cm x 44.45 cm x 60.3 cm (1.6 x 17.5 x 23.75 ) Weight 21.6 Kg (47 lb) DISK ARRAY ENCLOSURES 15 x 3.5 Disk Array Enclosure* 25 x 2.5 Disk Array Enclosure* Power AC Line Voltage 100 to 240 Vac± 10%, single-phase, 47 to 63 Hz 100 to 240 Vac± 10%, single-phase, 47 to 63 Hz AC Line Current (operating maximum) 2.8 A max at 100 Vac, 1.4 A max at 200 2.5 A max at 100 Vac, 1.3 A max at 200 Vac Vac Power Consumption (operating maximum) 280 VA (235 W) max 250 VA (230 W) max Power Factor 0.98 at full load, low voltage 0.98 at full load, low voltage Heat Dissipation (operating maximum) 8.46 x 105 J/hr, (800 Btu/hr) max 8.28 x 105 J/hr, (800 Btu/hr) max In-rush Current 50 A max for ½ line cycle, per line cord at 240 Vac 50 A max for ½ line cycle, per line cord at 240 Vac Startup Surge Current AC Protection AC Inlet Type 25 A max for ½ line cycle, per line cord at 120 Vac 10.6 A rms max for 100 ms, at any line voltage 10 A fuse on each power supply, both phases IEC320-C14 appliance coupler, per power zone 25 A max for ½ line cycle, per line cord at 120 Vac 10.6 A rms max for 100 ms, at any line voltage 10 A fuse on each power supply, both phases IEC320-C14 appliance coupler, per power zone Ride-through Time 30 ms 30 ms Current Sharing ± 10 percent of full load, between power supplies ± 10 percent of full load, between power supplies Dimensions Height (in/cm) 5.25 in/13.34 cm 3.45 in/8.76 cm Width (in/cm) 17.62 in/44.75 cm 17.62 in/44.75 cm Depth (in/cm) 14 in/35.56 cm 13 in/33.02 cm Weight (lb/kg) (with and without drives) Full: 67/30.45 Empty: 32/14.5 Full: 38.35/17.4 Empty: 22.1/10.0 *Ratings assume a fully loaded DAE that includes two power supplies, two LCCs, and 15/25 disk drives. OPERATING ENVIRONMENT Temperature: 50 104 degrees F (10 40 degrees C) Temperature 18 degrees F/hr (10 degrees C/hr) Gradient: Relative Humidity: 20% to 80% (non-condensing) Altitude: 7,500 ft. (2,286.4 m) @ 104 degrees F (40 degrees C) max 10,000 ft (3,048 m) @ 98.6 degrees F (37 degrees C) max

Electromagnetic Emmisions and Immunity FCC Class A EN55022 Class A CE Mark VCCI Class A (for Japan) ICES-003 Class A (for Canada) AS/NZS 3548 Class A (for Australia/New Zealand) EN55024 Immunity, ITE BSMI Class A (for Taiwan) Quality and Safety Standards UL 60950; CSAC 22.2-60950, EN 60950 Manufactured under an ISO 9000-registered quality system ETSI EN 300 386 Additional Standards Restriction of Hazardous Substances (RoHS) compliance www.lenovo.com 2014 Lenovo. All rights reserved. Lenovo, the Lenovo logo, ThinkServer and For Those Who Do are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. LenovoEMC and LifeLine are trademarks of LenovoEMC, Ltd.EMC2, EMC, the EMC logo, EMC Virtual Positioning, Atmos, E-Lab, ProSphere, PowerPath, Powerlink, Unisphere, UltraFlex, VNX, VNX5150 are registered trademarks or trademarks of EMC Corporation in the United States and other countries. VMware and the VMware logo are registered trademarks or trademarks of VMware, Inc., in the United States and other jurisdictions. Certain other product names, brand names and company names may be trademarks or designations of their respective owners.