IC+ NEW inverter compressor technology delivers energy saving, high performance cooling



Similar documents
08 FRIDGES & FREEZERS

Ultra-Low Temperature V.I.P. Series Freezers. Integrated Ultra-Low Temperature Storage Solutions for Biosafety, Security and Performance

MODEL NU C ULTRALOW TEMPERATURE FREEZERS

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

Freezers - Ultrafreezers. Platilab & Irilab Series

BIOMEDICAL REFRIGERATORS

-86 C ULTRALOW TEMPERATURE FREEZERS. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A

LABORATORY / MEDICINE / PHARMACEUTICAL REFRIGERATORS

Professional Kitchens

-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!

BR I Blood Bank Refrigerators

S G G S G G S G G S G G. FR / MF range. Deep Freezers & Plasma Storage Freezers

86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

Heating oven with mechanical convection

deli makes business more delicious! impulse coolers

LABOKLAV. Autoclaves Made in Germany.

Heating oven with mechanical control

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Blood Bank Refrigerators according to DIN Blood Plasma Freezers according to DIN 58375

Coldrooms designed for your application

STERILIZERS, LABORATORY DRYING OVENS

IV. Rear Mount System

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Screw Compressors ESM Fixed Speed & VS Variable Speed

Material test chamber with mechanical convection

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Nirvana. Cycling Refrigerated Dryers

LyoBeta. R+D Freeze-Dryers

Incubator with mechanical convection

STD - STANDARD VERSION extended possibilities reasonable price wide range of optional equipment

site monitoring Kit Site Monitoring Kit User Manual we prove it.

Undercounter & Slimline Cabinet Range HR/LR 120 HRB/LRB120 HR/LR 140 HR/LR 150 HR/LR 200 HR/LR 240 HR/LR 360 HR/LR 410

Climate chamber with illumination

FVA/A1 saturated-steam sterilizer

OT 40L / 90L. Laboratory Steam Sterilizers

Standard Features: Options:

Transport Boxes (active & passive systems)

ArcticStore. product guide environmentally friendly storage solutions

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

Hospital Sterilizers. T-Max Line

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Melting Point Range. with BioCote antimicrobial protection

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

MT I Transport Boxes (Active & Passive)

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

Horizontal Steam Sterilizers. Healthcare Line. Since

Natural geothermal energy.

Medical Waste Autoclaves. Medical Waste Autoclaves

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

SECTION MORTUARY REFRIGERATORS

Component Series Racks Component Series Rack Plus Bundles...3 Component Series stackable skeleton Racks...4

Our Vector range is growing, so can your profit. Vector Vector 1850

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction

SERVICE MANUAL REFRIGERATION

Melting Point Apparatus

Digital Ultra-Low Temperature Freezer. Digital Ultra-Low Temperature Freezer, Dual SHFS TM, Chest Type. Dual SHFS TM, Upright Type

German engineering under high pressure

Vertical and Benchtop Autoclaves for Life Sciences. Laboratory Line

MOBILE REFRIGERATED CONTAINERS REFRIGERATED CONTAINERS A WORLD OF COMFORT

RECALDO CLASSICO The reliable induction trolley for Cook & Chill, Cook & Serve and Cook & Freeze

Conserve O Gram. Cold Storage for Photograph Collections Using Individual Freezer Units. Introduction. Types of Freezers. August 2009 Number 14/11

CelCulture. CelCulture CO2 Incubator Model CCL-170_-_. CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications

BSL3 and BSL4 Autoclaves. Laboratory Line

Saving Energy. in the Food Retail Industry with SCHOTT Termofrost

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

Operations Manual Blast Chiller

S IJDERS SCIE TIFIC B.V.

Remote Alarm Monitoring System

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

KR25i HIGH SPEED, HIGH CAPACITY REFRIGERATED CENTRIFUGE AUTO-LOCK. CQCS Traceability System VIDEOset Display!

ThermoStar Refrigeration Air Dryers

HOSHIZAKI AMERICA, INC.

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

USER S MANUAL HSC-24A

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Clinic Washer-Disinfectors. Washer-Disinfector Line

Laboratory & Scientific Line. Horizontal Steam Sterilizers

How To Use A Power Supply Unit (Upu)

Advanced Test Equipment Rentals ATEC (2832)

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

User s Manual AURORA 1.2K/2.2K

TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series

Lighting. Midmark Animal Health Products

Rackmount Intelligent Pressure Scanners

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

Morgue refrigeration unit

Commercial Refrigeration Temperature and Defrost Controls

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

PowerGem Pro Uninterruptible Power Supply

Transcription:

-3ºC Biomedical Freezers With Inverter Control KM-MU28H1E / KM-MU9H1E l NEW inverter compressor technology delivers energy saving, high performance cooling l Outstanding reliability and performance for a wide variety of storage applications IC IC+ l Natural refrigerants for a reduced carbon footprint l Up to 6% reduction in power consumption for lower running costs 1) INVERTER CONTROLLED 1) Model KM-MU9H1E (82 litres) compared to the equivalent model MDF-U5312 at set-value -3 C, 3 C ambient, no load, 23V 5Hz. Actual energy use will depend on operating conditions. Securing samples, changing lives

New inverter technology in Biomedical freezers Panasonic NEW Inverter Technology saves energy and enhances sample security With the introduction of NEW inverter technology, Panasonic is offering exceptional performance and energy efficiency in our latest Biomedical freezers. Panasonic s new Biomedical freezers with natural refrigerants and inverter compressors minimise energy consumption, reduce environmental impact and save money on running costs. Innovative inverter technology provides a reliable and exceptionally stable temperature for a wide range of storage applications. The freezers provide effective storage of life-saving vaccines and samples for diagnosis in the medical field. They can also be used for storage of enzymes for genetic research, as well as culture media, reagents and samples for testing. Panasonic s Biomedical freezers are also ideal for industrial aging and temperature tests. As a storage environment, with excellent safety and other easy-to-use features, these freezers offer unsurpassed reliability and functionality. While conventional freezers use single speed compressors which cycle on and off, Panasonic's latest Biomedical freezers contain inverter compressors that can run at different speeds to maximise cooling performance under different conditions. As the compressor is not cycling on and off as frequently the temperature uniformity of the freezer is significantly improved. Inverter compressors have the added advantage of reducing the energy consumption of the freezer which is not only better for the environment but also helps to reduce running costs. 2

Improved energy efficiency and cooling performance through inverter technology normal compressor inverter controlled compressor Compressor speed (rpm) Door open Unit starting up Before door open After door open IC+ INVERTER CONTROLLED Inverter technology energy efficiency cost efficiency In a reciprocating compressor the action of the piston inside a cylinder causes the refrigerant to be compressed. The movement of the piston creates a vacuum inside the cylinder that draws the refrigerant in. The refrigerant is then compressed before flowing out of the cylinder to begin the refrigeration cycle. Time In a conventional reciprocating compressor the piston will always be working at full speed when the compressor is on to deliver maximum cooling capacity. Normally the load in the freezer is not high enough to need the maximum cooling capacity so the piston movement is excessive and energy is wasted. An inverter compressor can operate at different speeds depending on the ambient and load conditions. At times when the freezer only needs a minimal amount of cooling due to lower ambient temperatures, such as overnight, the compressor will move at a slower speed using much less energy. The start up of a compressor is the most energy consuming part of the cycle. The ability of the inverter compressor to run at lower speeds has the advantage that the compressor will not turn off and on as often thus saving energy and reducing wear. Inverter technology sample safety The intelligent control of the inverter compressor optimizes running speed for the conditions. When the inverter compressor is running as normal it will stay on for longer than a conventional compressor but at a minimal speed. This reduces the power consumption and keeps freezer temperatures stable. When the door has been opened the compressor will run at maximum capacity to bring the temperature inside the freezer back down to set value quickly before resuming a normal cycle again. 3

Features of the new Biomedical freezers Microprocessor Control Comprehensive set point, alarm, monitoring and diagnostic functions managed by a Panasonic-built microprocessor controller with digital display. The controller constantly monitors system conditions and notifies the user of abnormalities before a problem occurs. Safety Features l Audio and visual alarm system. l Adjustable high and low temperature alarms. l Self diagnostics. l Optional power failure alarm and remote alarm contacts. l Door lock as standard. l Door latch allows for a commercial padlock to be fitted for extra security. User Friendly Design Panasonic freezers are designed to offer ultimate ease of use. l The LED display panel is front mounted for easy reading and setting of parameters. l An access port is available for independent monitoring. l A quiet running compressor allows the freezer to be placed in busy working laboratories without disturbance. l Full height storage containers on each shelf. Temperature Recording (Optional) Circular or strip chart recorders are available for easy to use, accurate and reliable temperature recording. Storage containers are supplied as standard for increased user convenience Front-mounted display/control panel located at convenient height for easy access Door latch with provision for a padlock for extra protection of samples Insulated door with gasket for sample protection and uniformity Direct cooling through freezer circuits under each shelf for greater uniformity Universal keyed lock for added security Access port allows insertion of an independent monitoring probe Optional communication port available (see options) Natural hydrocarbon refrigerants are highly efficient, environmentally friendly and non-ozone depleting Door frame Hot-line and gasket design prevents ice build-up and reduces maintenance. Temperature recorder (optional) Pictured model is KM-MU9H1E NEW inverter controlled compressor for increased efficiency and performance Four casters and two adjustable levelling feet for easy installation

Biomedical freezer Features, Benefits and Performance Advantages Feature NEW inverter technology Natural refrigerants Panasonic designed refrigeration system Integrated control centre with self diagnostic function Structural enhancement Ergonomic design Compliant to international standards What It Does Gives flexible compressor operation for reduced energy consumption and increased temperature stability and uniformity. Provides more efficient cooling. Exceptionally low global warming potential. Highly durable and efficient cooling. Combines all control, alarm, monitoring and data management functions into a single system. Integrates inventory management, access and site installation. One handed door latches and quiet running compressors improve convenience. Assures quality standards, safety and performance criteria are met or exceeded. Why It Is Important Greater energy efficiency and lower running costs. Increased sample security through better control of freezer temperature. Greater energy efficiency and lower running costs. Better for the environment. Provides reliable storage of valuable samples and research material. High visibility LED display provides a convenient user interface to set points, alarm parameters, internal diagnostics and security. Cabinet design features include high strength lockable door latches and doors and locking castors to simplify operation and installation and to satisfy local codes. Easy access to controls and displays while low noise operation permits a wider choice of installation locations. Pull-out containers provide convenient and efficient storage for samples. Essential for compliance with international and national standards and recommended practices. The Panasonic microprocessor control system is secure, easy to use and comprehensive and can be accessed through a front mounted control panel. The microprocessor has a memory back-up so after a power failure, operation resumes at pre-outage settings. The self diagnostics function will display an error code in the case of an abnormality. Microprocessor Control Display Alarm indicator lamp glows when freezer is in alarm condition Alarm test verifies readiness of alarm function Buzzer key temporarily mutes audible alarm. Alarm ring back is factory set for 3 minutes (adjustable) Defrost mode Press to set temperature; set button is also used for diagnostic functions Digital display defaults to actual chamber temperature. Display mode changes when set point, alarm parameters and diagnostic functions are performed Set point entry advances digital display to next value from to 9 Set point entry advances digital display to next value 5

Natural Refrigerants Natural hydrocarbon (HC) refrigerants provide more efficient cooling due to their high latent heat of evaporation. As a result the refrigeration system offers greater energy efficiency. With an exceptionally low global warming potential, natural refrigerants are also better for the environment. Performance data KM-MU28H1E Performance data KM-MU9H1E Pull-down characteristics Pull-down characteristics. Ambient temp. 3ºC, no load. Ambient temp. 3ºC, no load 3. 23V / 5Hz 3. 23V / 5Hz Central air temp in chamber (ºC) 2. 1. -1. -2. -3. Central air temp in chamber (ºC) 2. 1. -1. -2. -3. -. - -.- 2 6 8 1 12 2 6 8 1 12 Time T (h) Time T (h) Pull-up characteristics during power failure Pull-up characteristics during power failure 3. Ambient temp. 3ºC, no load 2. Ambient temp. 3ºC, no load 2. 1. Central air temp in chamber (ºC) 1. -1. -2. -3. Central air temp in chamber (ºC) C -1. -2. -3. -. 2 6 8 1 12 T Time (h) -. 2 6 8 1 12 Time T (h) Dimensions (unit: mm) 65 61 38 61 98 91 79 358 162 129 2 27 27 27 28 37 58 635 598 5 86 196 81,5 38 8 8 658 37 58 88 772 71 525 85 91 692 98 26 692 1773 182 3 39 193 22 22 67 358 29 KM-MU28H1E 19 29 KM-MU9H1E 6

Specifications PUF = Rigid polyurethane foamed insulation V = Visual alarm B = Buzzer alarm R = Remote alarm KM-MU9H1E KM-MU28H1E Notes: 1) Exterior dimensions of main cabinet only, excluding handles and other external projections 2) Typical data individual units may vary and power consumption will depend on loading and operating conditions. Freezer set point -3 C, ambient temperature 2 C, unloaded, 23V 5Hz power supply 3) Air temperature measured at freezer centre, ambient temperature 3 C, no load ) Typical data (background noise: 2dB) 5) Power failure alarm optional, see KM-RPP1BB1W 6) Remote alarm contacts optional, requires KM-RPP1BB1W MODEL Dimensions External dimensions (W x D x H) 1) Internal dimensions (W x D x H) Volume Net weight (approx) Performance Energy consumption 2) Cooling performance 3) Temperature setting range Temperature control range 3) Control Controller Display Temperature sensor Refrigeration Cooling method Compressor Refrigerant Insulation material Insulation thickness Alarms Power failure High temperature (adjustable) Low temperature (adjustable) Construction Exterior material Interior material Outer door Outer door lock Storage containers Access port - position - diameter Casters Electrical and Noise Level Power supply Noise level ) Options Temperature recorders - Circular type - Recorder housing - Chart paper - Ink pen - Continuous strip type - Recorder housing - Chart paper Communications interface Data acquisition system Battery mounting box for power failure alarm mm mm litres kg kwh/2h C C C W mm qty qty ø mm qty db KM-MU28H1E 61 x 598 x 162 9 x 86 x 129 27 76 1.2 ABS resin 1 large / 1 small 1 Left-hand side -3-18 ~ -35-2 ~ -3 KM-MU9H1E 8 x 772 x 182 658 x 67 x 1272 82 12 1.35 Microprocessor, Non-volatile memory LED Thermistor Direct 25 (Hermetic/Inverter Control) HC (hydrocarbon) PUF 6 7 Optional V-B-R 5) V-B-R 6) V-B-R 6) Painted steel Styrol resin 2 Yes 3 6 medium / large 1 Rear 23V 5Hz Single phase MTR-G85C-PE MDF-S7T-PW MPR-S7-PW RP-G85-PW PG-R-PW MTR-15LH-PE MPR-S3-PW RP--PW MTR-8-PW (requires KM-RPP1BB1W) MTR-5-PW (requires MTR-8-PW) KM-RPP1BB1W *Appearance and specification are subject to change without notice. Panasonic is not responsible for any loss of content or damage to content. 7

Servicing and Validation At Panasonic we appreciate how much your samples and products are worth to you. Your chosen equipment has been manufactured using world leading technology and specialist engineering, so it is important that we continue to provide the best support and care possible to maximize the potential and lifespan of your equipment. We have a dedicated team of Panasonic Service Specialists who are trained to carry out repairs and service to our exacting standards, ensuring the support you need during the life of your equipment. Using our many years of experience and collaboration with our customers, we have designed a number of service options to suit your requirements and budget. During a Preventative Maintenance visit, using the latest technical information and recommended test equipment, our specialists will carry out extensive tests, and make any necessary adjustments to provide optimum performance. Panasonic is a vertical component manufacturer that can provide turn-key solutions for validation and qualification in accordance with all current GMPs, GLPs, GCPs, 21 CFR Part 11, PAT, ISO and specific customer requirements and applications. Because many of our key component parts are designed and built by Panasonic, we offer the most precise and in-depth validation resources specific to Panasonic laboratory products. Whatever your validation needs are, Panasonic provides comprehensive expertise in laboratory equipment to meet your exact compliance needs. Panasonic validation systems employ advanced technology coupled with the latest trends to ensure compliance with accurate and time efficient completion. IQ Installation Qualification Verifies and documents the equipment installation is compliant with the manufacturers requirements and specifications. OQ Operational Qualification Verifies and documents the full functional operation of the equipment. VALIDATION SOLUTIONS THERMAL VALIDATION User Requirement Manufacturer specs DQ(select equipment) Commissioning PQ Ensures User requirements are met OQ Verifies Manufacturer specs IQ Verifies Proper Setup PQ OQ IQ Please visit our website for more detailed information www.biomedical.panasonic.eu or check our facebook and twitter account @PHCBEU Panasonic-Biomedical-Sales-Europe-BV UK Office 9 The Office Village North Road, Loughborough Leicestershire LE11 1QJ United Kingdom Tel. +()159 265265 Fax. +()159 26977 biomedical.uk@eu.panasonic.com www.panasonic-biomedical.co.uk Head Office Nijverheidsweg 12 879 AZ Etten Leur The Netherlands Tel: +31 ()76 53 38 33 Fax: +31 ()76 51 37 32 biomedical.export@eu.panasonic.com www.biomedical.panasonic.eu France Office, avenue de Valvins, BP F-77212 Avon Cedex France Tel. +33 1 6719911 Fax. +33 1 6711693 biomedical.fr@eu.panasonic.com Panasonic Healthcare Co., Ltd., Gunma factory is certified for: Quality management system: ISO91 / Medical devices quality management system: ISO1385 / Environmental management system: ISO11 213 Panasonic Biomedical Sales Europe B.V. Publication Number: 2332EU