Attunity RepliWeb Failover Guide



Similar documents
Installing RMFT on an MS Cluster

RepliWeb Topology Manager. User Guide

Attunity RepliWeb PAM Configuration Guide

Attunity RepliWeb Event Driven Jobs

RMFT Event Viewer Messages

RDS Directory Synchronization

RMFT Outlook Add-In User Guide

DocAve 4.1 SharePoint Disaster Recovery High Availability (SPDR HA) User Guide

Failover Manager for WhatsUp Gold v16.0 Quick Start Guide

For Active Directory Installation Guide

Using Microsoft Windows Authentication for Microsoft SQL Server Connections in Data Archive

Configuration Guide. for the Lepide User Password Expiration Reminder

2X Cloud Portal v10.5

StarWind iscsi SAN Software: Using StarWind with MS Cluster on Windows Server 2008

StarWind iscsi SAN Software: Installing StarWind on Windows Server 2008 R2 Server Core

Deploying BitDefender Client Security and BitDefender Windows Server Solutions

EventTracker: Support to Non English Systems

Quick Start Guide for VMware and Windows 7

Introduction to Hyper-V High- Availability with Failover Clustering

StarWind iscsi SAN Software: Tape Drives Using StarWind and Symantec Backup Exec

Universal Management Service 2015

VMware/Hyper-V Backup Plug-in User Guide

Oracle Enterprise Manager

StarWind Virtual SAN Installation and Configuration of Hyper-Converged 2 Nodes with Hyper-V Cluster

Deploying System Center 2012 R2 Configuration Manager

Secure Agent Quick Start for Windows

CRM to Exchange Synchronization

Quick Start Guide For Ipswitch Failover v9.0

Installation Guide. Novell Storage Manager for Active Directory. Novell Storage Manager for Active Directory Installation Guide

XenClient Enterprise Synchronizer Installation Guide

Setting up Hyper-V for 2X VirtualDesktopServer Manual

StarWind SMI-S Agent: Storage Provider for SCVMM April 2012

Installation & Upgrade Guide. Hand-Held Configuration Devices Mobility DHH820-DMS. Mobility DHH820-DMS Device Management System Software

Pipeliner CRM Phaenomena Guide Sales Pipeline Management Pipelinersales Inc.

SOA Software API Gateway Appliance 7.1.x Administration Guide

StarWind iscsi SAN & NAS: Configuring HA Storage for Hyper-V October 2012

Citrix Systems, Inc.

Lab Answer Key for Module 6: Configuring and Managing Windows SharePoint Services 3.0. Table of Contents Lab 1: Configuring and Managing WSS 3.

ArCycle vmbackup. for VMware/Hyper-V. User Guide

Project management integrated into Outlook

uh6 efolder BDR Guide for Veeam Page 1 of 36

Project management integrated into Outlook

StarWind iscsi SAN Software: Using StarWind with MS Cluster on Windows Server 2003

HC SHAREPOINT SERVICES MODULE SERVER CONFIGURATION. User Manual. Hosting Controller All Rights Reserved.

TROUBLESHOOTING GUIDE

Lab Answer Key for Module 9: Active Directory Domain Services. Table of Contents Lab 1: Exploring Active Directory Domain Services 1

StarWind iscsi SAN Software: Providing shared storage for Hyper-V's Live Migration feature on two physical servers

PANO MANAGER CONNECTOR FOR SCVMM& HYPER-V

StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover Cluster

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

Quick Start Guide for Parallels Virtuozzo

StarWind Virtual SAN Hyper-Converged Platform Quick Start Guide

Hands-On Lab: WSUS. Lab Manual Expediting WSUS Service for XP Embedded OS

Omniquad Exchange Archiving

Deploying BitDefender Client Security and BitDefender Windows Server Solutions

Installation Guide. . All right reserved. For more information about Specops Inventory and other Specops products, visit

Adobe Acrobat 9 Deployment on Microsoft Windows Group Policy and the Active Directory service

By the Citrix Publications Department. Citrix Systems, Inc.

Dell Statistica Statistica Enterprise Installation Instructions

Xcalibur Global Version 1.2 Installation Guide Document Version 3.0

ITA Mail Archive Setup Guide

1. Installation Overview

NETWRIX CHANGE NOTIFIER

VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide

CA Nimsoft Monitor Snap

StarPort iscsi and ATA-over-Ethernet Initiator: Using Mirror (RAID1) disk device

Configuration Guide. Follow the simple steps given in this document when you are going to run Lepide Active Directory Cleaner for the first time.

Lepide Exchange Recovery Manager

Setting Up a Backup Domain Controller

StarWind iscsi SAN & NAS: Configuring HA File Server on Windows Server 2012 for SMB NAS January 2013

Synchronization Agent Configuration Guide

Setting up Hyper-V for 2X VirtualDesktopServer Manual

Thinspace deskcloud. Quick Start Guide

NovaBACKUP xsp Version 12.2 Upgrade Guide

XStream Remote Control: Configuring DCOM Connectivity

CCH Audit Automation. Version 4.4 Service Pack 2.1. Release Notes

Acronis Backup & Recovery 11.5 Quick Start Guide

Nexio Connectus Cluster Set Up with SQL Server Backend

MadCap Software. Upgrading Guide. Pulse

Windows XP Service Pack 2 Windows Firewall Group Policy Setup for Executive Software Products

Installation Overview

Step by step guide for installing highly available System Centre 2012 Virtual Machine Manager Management server:

Setting up VMware ESXi for 2X VirtualDesktopServer Manual

Veritas Cluster Server Database Agent for Microsoft SQL Configuration Guide

Specops Command. Installation Guide

Pulse Redundancy. User Guide

System Management Console User Guide

Active Directory Provider User s Guide

Virtual Desktop Infrastructure in

Parallels Virtuozzo Containers 4.6 for Windows

ScriptLogic File System Auditor User Guide

Sophos Anti-Virus for NetApp Storage Systems startup guide

WINDOWS 7 & HOMEGROUP

Configuration Guide. Remote Backups How-To Guide. Overview

Symantec Backup Exec Management Plug-in for VMware User's Guide

Dell Statistica Document Management System (SDMS) Installation Instructions

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

Step-by-Step Guide for Microsoft Advanced Group Policy Management 4.0

StarWind iscsi SAN & NAS: Configuring HA Shared Storage for Scale- Out File Servers in Windows Server 2012 January 2013

Transcription:

Attunity RepliWeb Failover Guide Software Version 5.2 June 25, 2012 RepliWeb, Inc., 6441 Lyons Road, Coconut Creek, FL 33073 Tel: (954) 946-2274, Fax: (954) 337-6424 E-mail: info@repliweb.com, Support: http://support.repliweb.com

2012 Attunity Ltd. All rights reserved. The information in this manual has been compiled with care, but Attunity Ltd. makes no warranties as to its accuracy or completeness. The software described herein may be changed or enhanced from time to time. This information does not constitute a commitment or representation by Attunity and is subject to change without notice. The software described in this document is furnished under license and may be used and/or copied only in accordance with the terms of this license and the End User License Agreement. No part of this manual may be reproduced or transmitted, in any form, by any means (electronic, photocopying, recording or otherwise) without the express written consent of Attunity Ltd. Windows, Windows XP and Windows Vista are trademarks of Microsoft Corporation in the US and/or other countries. UNIX is a registered trademark of Bell Laboratories licensed to X/OPEN. Any other product or company names referred to in this document may be the trademarks of their respective owners. Please direct correspondence or inquiries to: RepliWeb, Inc. 6441 Lyons Road Coconut Creek, Florida 33073 USA Telephone: (954) 946-2274 Fax: (954) 337-6424 Sales & General Information: Documentation: Technical Support: Website: info@repliweb.com docs@repliweb.com http://support.repliweb.com http://www.repliweb.com ii

Table of Contents 1. Overview... 1 2. Prerequisites... 2 3. Console GUI... 3 iii

1. Overview The Failover process enables R-1 administrators to maintain a Backup (standby) server that will be used as the R-1 Center in case the Primary Server is temporarily shut down. Failover is an important fault tolerance function of mission-critical systems that rely on constant accessibility. The backup server is automatically and transparently to the user being updated with all R-1 Center files, so when the need arises, it can replace the primary server and act as an R-1 center, running all replication and distribution jobs as before. The Failover process updates the Failover server with the following R-1 information: Scheduled Jobs - This includes all Continuous Update, Scheduled and On-Demand jobs Templates Common and User-specific Containers Common and User-specific Configuration Files Preference Files Note: The Failover process does NOT copy any content from the primary server to the failover server. This is the responsibility of the user/administrator. 1

2. Prerequisites The Failover and Primary server should be of the same platform (Windows Windows, Linux Linux, etc.). Note: The Failover server must be a different machine than the Primary server. The Failover Server must contain a complete R-1 installation, using the same R-1 version, installed on exactly the same path as the R-1 Center initiating the Failover process. Install at least the Center and Edge components; the Console is optional. The Failover process will fail if these requirements are not met. The Failover process does NOT copy any content from the Primary server to the Failover server. This is the responsibility of the user/administrator. Note: Content in the replication Source Directories is not replicated to the Failover server by the Failover process. 2

3. Console GUI Using the R-1, REM or RCM Console, define and activate the Failover process. Figure: Internal Process Failover To configure the Failover process: 1. Install R-1 on both the primary and failover servers. Make sure at least the Center and Edge components of the same R-1 version are installed on exactly the same path on both servers and that the failover and primary servers are of the same platform (Windows Windows, Linux Linux, etc.). The failover process will fail if these requirements are not met. If you have a ROSS Center installed on one server, make sure the same ROSS Center version is also installed on the other server. Note: The failover server must be a different machine from the primary server. 2. On the failover server, set the RDS Scheduler service to start manually, so it won t start automatically in case of a reboot. 3. On the primary server, open the Failover tab, select the Enable Automated Failover checkbox to run the Failover process manually and specify the connection credentials and run options. To disable the Failover process, unselect this checkbox. 3

Console GUI The option selected will start when you click the Apply button. a. In the Connection Credentials area, specify the credentials that the Failover process will use to connect to the failover server, as follows: i. In the Failover Server field, enter the host name or IP address of the R-1 Center being used as the failover server. ii. In the User field, enter the user name that the Failover Process will use. iii. In the Password field, enter the password for the account specified in the User field. iv. In the Domain field, enter the domain if the user is part of a domain. If it is not, leave this field blank. Note: Jobs submitted to the failover server should be configured to use the same machine name as specified in the Failover tab. b. In the Run Options area, specify how to run the Failover process: i. Schedule the Failover process to either run immediately or at fixed intervals, as follow: ii. iii. o o Run Immediately Run the Failover process immediately when the primary server goes down. This option only runs once meaning that all the jobs/templates that currently exist on the Center will be transferred to the Failover Center just once. Run Every Run the Failover process at a specific time interval (days/hours/minutes). To change the port being used for the failover job, select the Use Alternate Port checkbox and specify the new port number to use. To specify the intervals at which the Failover report will be cleaned, select the Report Cleanup checkbox and specify the interval value, in minutes. 4. Click Apply to save changed settings. If the Failover is enabled, saved settings take effect immediately. When the failover process is enabled on the primary server, the RDS Scheduler service is automatically stopped on the failover server. The failover process copies scheduled job definitions, Templates, Containers and all configuration files required for the failover server to act as the primary server when needed. The Failover process does NOT copy content from the primary server to the failover server. 5. In the Running Details pane, you can view the Failover job s state, completion message and report. To refresh the displayed information, click Refresh. Using the Failover Server The failover server should get the IP/DNS and NAME of the primary server. This should be done according to corporate policy to allow previously scheduled jobs to continue uninterrupted without resubmitting. 4

Console GUI To use the failover server: 1. When the primary server goes down, start the R-1 Scheduler service on the failover server. Using Windows: a. From the Windows Start menu select Control Panel Administrative Tools Services. b. Start the service named RDS Scheduler. c. Set the RDS Scheduler service to start automatically. Using UNIX: Start the repliweb_scheduler: /usr/bin/repliweb_scheduler 2. Open R-1 Console and connect to the failover server. 3. In the failover Center s Console GUI, go to Manage/Center/Scheduler and select the Allow local admin to view all jobs checkbox. This is necessary because the primary server jobs are running under a different user context. 4. From the Console GUI, re-connect to the failover Center. The failover server now acts as the primary server. For any additional information, contact us at support.repliweb.com 5