Monitor Desfibrilador Monitor Defibrillatore



Similar documents
X Series Extensive Capabilities

HEARTSTART XL DEFIBRILLATOR/MONITOR Model: M4735A PRODUCT DESCRIPTION

MEDIANA Corporate Profile. Contents

INNOC. Innocare-T. Innomed. Innomed s intensive and anesthesiological monitor system can be used both as a transport or bed-side care unit

OMNI TOUCH SCREEN PATIENT MONITOR

Concept. Monitoring Unit. Patient Box. Defibrillator/Pacer Unit.

LIFEPAK 15 MONITOR/DEFIBRILLATOR

R Series Quick Reference Guide

Power to see the big picture

LIFEPAK 15 MONITOR/DEFIBRILLATOR OPERATING INSTRUCTIONS

HEARTSTART MRx MONITOR/DEFIBRILLATOR

Introducing the first 12-lead for the BLS team.

>DEFIBRILLATION AEDs (Automatic External Defibrillators)

Philips PageWriter Touch ECG System

Ready to save lives. Philips HeartStart XL+ Defibrillator/Monitor

PRODUCT BROCHURE LIFEPAK 15 MONITOR/DEFIBRILLATOR. For Emergency Medical Services

All Products of MEDIANA. All because of you,mediana will be better...

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Vista 120 Patient Monitor

( (

Quick Connect. quick - simple - efficient.

Welch Allyn 1500 Patient Monitor Train the Trainer

How To Use A Welch Allyn 1500 Patient Monitor

LIFEPAK 20e DEfibrillator/MONITOR. Works like you work.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

touchecg Reference Markets your profession, our mission

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

USB-500/600 Series Low-Cost Data Loggers and Accessories

CLASS D POWER AMPLIFIERS

Ready to save lives. Philips HeartStart XL+ Defibrillator/Monitor

iva Cable & Antenna Analyzer

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Infinity M540 monitor

X Series Operator s Guide

CARESCAPE VC150 Vital Signs Monitor. Connecting intelligence and care.

NGAUS Domestic Operations Task Force (Joint) Brenda Butler, Vice President Government Sales William Smirles, Director of Business Development

rigel 288 Electrical Medical Safety Analyser Key Features Applications

Assembled in Florida, USA.

Masimo Patient Safetynet HL7 Interface Specifications

SOLAR300N Rel /01/10

LIFEPAK 12 DEFIBRILLATOR/MONITOR OPERATING INSTRUCTIONS

Server Remote Control

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

ACCESSORIES BROCHURE LIFEPAK 15 MONITOR/DEFIBRILLATOR. Genuine Accessories from Physio-Control PHYSIO-CONTROL IS A DIVISION OF MEDTRONIC

ACCESSORIES BROCHURE. LIFEPAK 20/20e. DEFIBRILLATOR/MONITOR with CodeManagement Module TM. Genuine Accessories from Physio-Control

Electronic Control Devices The European Product Catalogue 2007

CardioCard System. Product Specification and Sample Reports. PC-Based ECG CardioCard. PC-Based Stress. PC-Based Holter. CardioCard.

Albiral 15 Data retractable monitor, brushed stainless steel cabinet Ref: 150EJSMI

SpO2 PULSE OXYMETER MD-300

Electronic Control Devices The European Product Catalogue 2007

Product Specification instalert Rapid Messenger Variable Message Sign

Raptor RXi Ultra-fast scanning Countersurveillance Receiver

Monitoring Product line

TERMINAL TACTIL A COLOR CON PLC INTEGRADO Pag 2. TERMINAL TACTIL MONOCROMO CON PLC INTEGRADO Pag 4. PANEL OPERADOR CON PLC INTEGRADO Pag 9

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

WD-AMX Water Detection Controllers

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

iva Cable & Antenna Analyzer

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Serie Idegis Tecno. Piscina Privada / Private Pool

Thyristor-controlled power supplies and battery chargers

D A cost effective monitor that meets your clinical needs VISTA 120

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Agilent 4338B Milliohm Meter

Technical Data. back-up time in minutes 100% load % load

High-intensity performance. IntelliVue MP90 patient monitor

SureSigns VM Series Patient Monitors

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Quick Installation Guide TK-RP08. H/W: v1.0r

Digital input modules

Everything you need for protection scheme testing

Multi-Function Ground

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Uninterruptible Power Supply

VITALMONITOR SOFTWARE FOR PATIENT MONITORING

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Spirodoc. 3D Laboratory for respiratory analysis two functional modes: doctor and patient. Four devices in one. Spirometer with Touch Screen display

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Boaray 700 Anesthesia Machine

GE Healthcare. B40 Patient Monitor Connecting intelligence and care.

Type-D EEG System for Regular EEG Clinic

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

TORKEL 820 Battery Load Unit

Critical Care Therapy and Respiratory Care Section

Company Profile & product presentation.

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Simpler on the outside. Smarter on the inside.

GPS Vehicle and personal location tracker. User manual

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

8 Port USB + PS/2 Digital KVM Switch with OSD. StarTech ID: SV841HDI

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Transcription:

Reanibex Serie 800 Monitor Defibrillator Monitor Desfibrilador Monitor Defibrillatore reddot design award product design 2013 FEATURES Manual and Automated Biphasic Defibrillator up to 360 Joules. Lightweight equipment with monitoring and diagnostic capabilities. Large colour display (8.4 ). Sychronized Cardioversion. 3, 5 and 10- lead patient cable. CPR Metronome with feedback. AED in Pediatric. High performance with ease of use and very intuitive. Modular. Easily upgradeable. Plug and play system to add new options. 12-lead ECG data transmission from the field to the Emergency Service. Masimo Rainbow SET technology that monitors SpO2, Carboxyhemoglobin and Methemoglobin (optional). Oridion capnography. Microstream technology (optional). Non-invasive Blood Pressure from SunTech Medical (optional). Invasive Blood Pressure from MEDLAB (two lines) (optional). Temperature from MEDLAB (two lines) (optional). 12-Lead Interpretive Algorithm (University of Glasgow) (optional). Operates from the mains (AC), from a vehicle battery (DC) and with its internal battery. 220VAC, 12VDC and with 1 or 2 batteries. CARACTERÍSTICAS Desfibrilador Bifásico Manual y Automatizado hasta 360 Julios. Equipo ligero con capacidad de monitorización y diagnóstico. Amplia pantalla color (8,4 ). Cardioversión sincronizada. Cable de paciente de 3, 5 y 10 latiguillos. Metronomo RCP. DEA en modo pediátrico. Altas prestaciones con un uso fácil y muy intuitivo. Modular. Fácilmente ampliable. Sistema Plug and Play para añadir nuevas opciones. Transmisión de las 12 derivadas ECG del escenario de actuación a la central de Emergencias. Monitorización de SpO2, Carboxihemoglobina y Metahemoglobina con tecnología Masimo Rainbow SET (opcional). Capnografía de Oridion. Tecnología Microstream (opcional). Presión sanguínea no invasiva de SunTech Medical (opcional). Presión invasiva de MEDLAB (dos salidas) (opcional). Temperatura de MEDLAB (dos salidas) (opcional). Algoritmo de interpretación de 12 derivadas (Universidad de Glasgow) (opcional). Funcionamiento desde la red (CA), desde la batería de un vehículo (CC) y con su batería interna. Alimentación a 220VCA, 12VCC y con 1 o 2 baterías. CARATTERISTICHE Defibrillatore bifasico manuale e seni automatico fino a 360 joule. Dispositivo leggero con funzionalità diagnostiche e di monitoraggio. Ampio display a colori (8,4 ). Cardioversione sincronizzata. Cavo paziente a 3, 5 e 10 derivazioni. Metronomo con feedback sulla RCP. AED pediatrico Performance elevate, facile da utilizzare e molto intuitivo. Modulare. Facilmente espandibile. Sistema plug and play per l aggiunta di nuove opzioni. Trasmissione dell ECG a 12 derivazioni. Tecnologia Masimo Rainbow SET per il monitoraggio di SpO2, carbossiemoglobina e metaemoglobina (opzionale). Capnografia Oridion. Tecnologia Microstream (opzionale). Tecnologia SunTech Medical per la misurazione non invasiva della pressione arteriosa (opzionale). Pressione invasiva (due canali) MEDLAB (opzionale). Temperatura (due canali) MEDLAB. Interpretazione dell ecg a 12 derivazioni (Algoritmo dell Università di Glasgow) (opzionale). Funzionamento con alimentazione da corrente di rete (CA), batteria auto (CC) e batteria interna. Alimentazione a 220V/CA - 12V/CC e con 1/2 batterie.

01 Therapy selector. Selector de terapia. Selettore terapia. 02 Status Indicator. Indicador de estado. Indicatore di stato. 07 Large Colour Scren organised by functional areas. Sun mode. Amplia Pantalla en color organizada por zonas funcionales. Modo sol. Ampio monitor a colori organizzato per aree funzionali nodalita. Sole mode. 03 Optional Modules. Plug &Play System. Módulos opcionales. Sistema Plug&Play. Moduli opzionali. Sistema Plug & Play. 04 Non invasive pacing (Optional). Marcapasos no invasivo (Opcional). Pacing non invasivo (Opzionale). 05 External reusable paddles with contact indicator on the APEX paddle. Palas externas reutilizables con indicador de contacto en Pala APEX. Piastre esterne riutilizzabili con indicatore di contatto sulla piastra APICALE. 06 Automated Defibrillator for Adult and pediatric. Desfibrilador Automatizado para adulto y pediátrico. nodalita AED per adulti e pediatrici. 08 Bluetooth transmission (Optional). Transmisión Bluetooth (Opcional). Trasmissione Bluetooth (Opzionale). 09 106 mm Printer (Optional). Registrador de 106 mm (Opcional). Stampante da 106 mm (Opzion). 10 Compact Flash memory card. Tarjeta de memoria Compact Flash. Scheda di memoria Compact Flash. 11 12 ECG adquisition key. Tecla para la adquisición de 12 ECG. Tasto dedicato per l acquisizione di 12 ECG. ACCESSORIES (OPTIONAL) Carrying case. Ambulance bracket (EN1789). 3/ 5/ 10- lead patient cable. REANIBEX Data Manager. PC Software for managing the information recorded by the device. Smartphone application (for Bluetooth option). Internal paddle. ACCESORIOS (OPCIONAL) Bolsa de transporte. Soporte para ambulancia (EN1789). Cable de paciente de 3/ 5/ 10 latiguillos. REANIBEX Data Manager. Aplicación Software para gestión de todos los datos registrados por el equipo. Aplicación Smartphone (para la opción de Bluetooth). Palas internas. ACCESSORI (OPZIONALE) Borsa per il trasporto. Supporto per ambulanza (EN1798). Cavo paziente a 3, 5 e 10 derivazioni. REANIBEX Data Manager. Software PC per la gestione delle informazioni registrate dal dispositivo. Applicazione Smartphone (per opzione Bluetooth). Piastre interne. OPTIONS 01 Non invasive pacing. 02 Pulse oximeter. SpO2/ SpMet/ SpCO/ PVI/ SpHb/ SpOC. 03 Capnography. Microstream technology from Oridion Medical. 04 Non-invasive blood pressure from SunTech Medical. 05 Bluetooth data transmission to PDA or Computer and from the PDA to a web server. 06 Temperature module from MEDLAB. 07 Invasive Blood Pressure module from MEDLAB. 08 12-Lead Interpretive Algorithm. (University of Glasgow). OPCIONES 01 Marcapasos no invasivo. 02 Pulsioximetro. SpO2/ SpMet/ SpCO/ PVI/ SpHb/ SpOC. 03 Capnografía. Tecnología Microstream de Oridion Medical. 04 Presión sanguínea no invasiva de SunTech Medical. 05 Transmisión Bluetooth a PDA o PC y de la PDA al servidor web. 06 Módulo de Temperatura de MEDLAB. 07 Módulo de presión invasiva de MEDLAB. 08 Interpretación de 12 derivadas. (Universidad de Glasgow). OPZIONI 01 Pacing non invasivo. 02 Pulsiossimetro. SpO2/SpMet/SpCO/PVI/SpHb/SpOC 03 Capnografia. Tecnologia Microstream di Oridion Medical. 04 Tecnologia SunTech Medical per la pressione arteriosa non invasiva. 05 Trasmissione dati Bluetooth. 06 Modulo Temperatura MEDLAB (2 canali). 07 Modulo Pressione invasiva MEDLAB (2 canali). 08 Interpretazione dell ecg a 12 derivazioni. (Università di Glasgow). Rev:10/2014

GENERAL Dimensions Weight DEFIBRILLATOR Waveform Energy delivery Output energy accuracy Charging Time Range of patient impedances MANUAL MODE Selectable energy levels Energy selection control Charging control Synchronised cardioversion Indicators Available energy indicators AED MODE Selectable energy levels Audible and on screen messages Available energy indicators Indicators Defibrillable rhythms Specificity and sensitivity of the detection algorithm Resuscitation guidelines 300 mm (H) x 260 mm (D) x 350 mm (W) Basic equipment with AC/DC module: 7,6 kg External paddles: 0,95 kg Battery: 0,8kg Biphasic truncated exponential adjusted to the impedance of the patient By means of reusable external paddles for adults (integrated pediatric paddles), internal paddles or multifunction disposable electrodes ± 15% or ± 3 Joules, the highest, over the range Less than 5 seconds at 200 Joules with a new fully charged battery Less than 7 seconds at 360 Joules with a new fully charged battery 15 to 200 Ohms 1-10, 15, 20, 30, 50, 70, 100, 125, 150, 175, 200, 250, 300 and 360 Joules Therapy selector on the front panel Key on the front panel or key on the reusable external paddles SYNC key on the front panel Text and audible messages, audible alerts, status indicator, battery indicator, synchronisation mode, equipment connected to external power source indicator Charging tone, available energy tone, flashing discharge button, indication of energy level on the screen Adult patient: from 150 to 360 Joules Pediatric patient: from 40 to 90 Joules They guide the user through the operating protocol Charging tone, available energy tone, flashing discharge button, message and icon on screen Text and audible messages, audible alerts, status indicator, battery indicator, equipment connected to external power source indicator Ventricular fibrillation and rapid ventricular tachycardia Fulfils AHA requirements Factory set Guidelines 2010 (ERC/AHA) ECG MONITOR Inputs Up to 3 ECG waveforms can be viewed on the sceen 3 - lead patient cable: Leads I, II or III 5 - lead patient cable: Leads I, II, III, avf, avl, avr and V 10 - lead patient cable: Leads I, II, III, avf, avl, avr and from V1 to V6 The ECG signal can be obtained through reusable external paddles, internal paddles or disposable multifunction electrodes 2.5, 5, 10, 20, 40 mm/mv and auto-gain Sensitivity Heart Rate From 30 to 300 bpm (accuracy ± 10%) Reanibex Serie 800 Technical Specifications

Common mode rejection More than 100 dbs (IEC 60601-2-27) Frequency response Mains filter: 50 Hz or 60 Hz On recorder: 0,67 40 Hz or 1 30 Hz or 0,05 150 Hz (diagnostic mode) On screen: 0,67 40 Hz or 1 30 Hz Patient isolation ECG: Type CF SpO2: Type CF NIBP: Type CF EtCO2: Type CF TEMP: Type CF IP: Type CF Defibrillator: Type CF 12 - LEAD ECG AND INTERPRETATION Input With a 10 -lead patient cable the signals obtained are: I, II, III, avr, avl, avf and from V1 to V6. These signals can be printed on the recorder in 3 x 4, 3x4+1R or 3x4 + 3R format Analysis algorithm Glasgow University algorithm 12 lead transmission From the equipment to a PDA and from the PDA to a remote server PACEMAKER Waveform Rectangular constant current Pulse width 40 ms (accuracy: ± 10%) Amplitude From 0 to 200 ma (accuracy:± 10%) Frequency From 30 to 180 ppm (accuracy:± 10%) Operating modes Fixed and on demand Refractory period 340 ms from 30 to 80 ppm 240 ms from 85 to 180 ppm SpO2 PULSE OXIMETRY Range 0 to 100 % Accuracy Without movement: 2%. Pulse rate Pulse rate accuracy Optional parameters NON-INVASIVE BLOOD PRESSURE Range With movement: 3% 25 to 240 ppm Without movement: 3 ppm With movement: 5 ppm SpMet, SpCO, SpHb, PVI and SpOC Systolic pressure: 40-260 mmhg. Diastolic pressure: 20-200 mmhg Mean arterial pressure: 26-220 mmhg Fulfils the requirements of the ANSI/AAMI SP10:1992 and 2002 standards Accuracy Transducer accuracy ± 3 mmhg from 0 mmhg to 300 mmhg for an operating temperature between 0 and 50 C Initial pressure 160 mmhg (by default for adult patients) 120 mmhg (by default for pediatric patients) Pulse rate range 30 to 220 ppm Pulse rate accuracy ± 2% or 3 ppm, the greater Automatic measurement interval Configurable from 1 to 60 minutes Measurement time Average of 30 seconds, 130 seconds maximum Calibration Annually Reanibex Serie 800 Technical Specifications

END-TIDAL CARBON DIOXIDE Range Resolution Accuracy Sample size Calibration AIRWAYS RESPIRATION RATE Range Resolution Accuracy From 0 to 99 mmhg 1 mmhg (0,1 kpa) Between 0 and 38 mmhg: ± 2 mmhg Between 39 and 99 mmhg: ± 5% of the reading + 0,08% every 1 mmhg (avobe 4 mmhg) 50 ml per minute Annually or after 4.000 hours of operation From 0 to 150 breaths/minute (bpm) 1 bpm From 0 to 70 bpm: ± 1 bpm From 71 to 120 bpm: ± 2 bpm From 121 to 150 bpm: ± 3 bpm INVASIVE PRESSURE Transducer sensitivity 5 uv/v mmhg Sensitivity adjustment range ± 10% Frequency response 0-28 Hz (-3 dbs) Range From -99 to 310 mmhg Measurement resolution ±1 mmhg Pulse rate range From 30 to 250 bpm TEMPERATURE Range From 20,0 ºC to 44,0 ºC Measurement resolution 0,1ºC Measurement accuracy (excluding any adapter cable) 0,1 C for an ambient temperature of 10 to 40 C (temperature probe adds an additional ± 0,1 C for an ambient temperature of 32 to 42 C. SCREEN Size Type Resolution Sweep rate Display time 8,4 (diagonal) TFT colour 800 x 600 pixels 25 mm/s for the ECG, SpO2 and pressure waveforms, and 6,25 or 12,5 mm/s for the CO2 waveform 5,4 seconds for the ECG signal (10,8 seconds in cascade mode) PRINTER Type Thermal array Paper width 50 mm (106 mm optional) Speed 10, 25 and 50 mm/s (accuracy: ± 5%) Operating modes Manual: Start/stop the printer using the key on the front panel. The ECG trace is printed with all events and measurements. Automatic: The equipment can be configured so that it prints automatically when a marker is introduced, when a discharge is performed or when there is an alarm. Delay: Waveforms are printed with a delay of 8 seconds after the screen display. Reports Operating reports, trends, 12 - leads reports, configuration parameters, last tests results, equipment information and information of the events stored in the memory card. Reanibex Serie 800 Technical Specifications

DATA STORAGE Internal memory Compact Flash memory card Stores the operation report and all the parameters monitors up to a maximum of 24 hours from switching on Stores the continuous ECG signal with all the events and the audio (optional and only in AED mode). Stores the last 100 along with their associated ECG signal. BATTERY Type NiMH rechargeable 3 A/h 12 V Capacity More than 150 shocks at 360 Joules with a new fully charged battery at 25ºC More than 210 minutes of monitoring. More than 140 minutes of monitoring with ECG, SpO2, CO2 and NIBP measurement every 15 minutes. Recharging time Approximately 3 hours Battery indicators Capacity and battery status indicator on the screen. Low battery indicator, absence of battery and battery charging on the status indicator ENVIRONMENT Operating temperature From 0 to 45 ºC Storage temperature From -20 to 60 ºC Humidity 10 to 95 % non-condensing Altitude 0 to 4000 m Shocks EN 1789 Vibrations EN 1789 Resistance to solids/water IPX4. Test performed with cables connected to the equipment EMC Complies with IEC 60601-1-2:2007 Safety Complies with IEC 60601-1 Other aspects The equipment is not suitable to be used in the presence of concentrated oxygen Operating mode Continuous AC Supply Input: 100-240 VAC, 50/60 Hz, 2,5 A Output: 15 V, 9,3 A, max 140 W Battery 12 V rechargeable NiMH battery DC Supply 10-16 VDC, 10 A Rev: 10/2014