Standard For Lining Ductile Iron Pipe and Fittings For Sewer Service



Similar documents
PROTECTO 401 CERAMIC EPOXY LINED DUCTILE IRON PIPE AND FITTINGS

PRODUCT DATA SHEET DESCRIPTION:

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

POLYURETHANE LINING AND COATING ON PIPE RAW WATER

3M Scotchkote Urethane Coating 165HB

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

INDEX. Sec. No. Items Page Nos.

SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Specification for Pipe Coating Repairs Offshore

T R A N S F E R A B L E F U L LY

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents.

TECHNICAL REQUIREMENTS AND SPECIFICATIONS

IS800 Series. Technical Data Sheet IS802, IS803, IS808, IS Description. Key Features and Benefits. Typical Physical Properties

SECTION POLYVINYL CHLORIDE (PVC) PIPE

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

Minor Cracks in Horizontal Surfaces

INDUSTRIAL FLOORING INSTALLATION CHALLENGES. James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Special Linings for unusual service conditions. Please contact ACIPCO.

BRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment:

STANDARD SPECIFICATIONS SECTION CLEANING AND LINING WATER MAINS

Material Product Data Sheet Sealers for Thermal Spray Coatings

SECTION STORM DRAINAGE SYSTEM

Pipe Protection Tape System

Treatment of a surface or structure to resist the passage of water in the absence of hydrostatic pressure. presence of hydrostatic pressure.

WATERPROOFING OF WET ROOMS

A. Work on this project shall consist of, but is not limited to, the following:

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

Rehabilitation of an Aging Concrete Reservoir Adit Tower

RTV159. RTV157 and RTV159 High Strength Silicone Adhesive Sealants

SECTION ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL

Anodizing Reference Guide

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING REPORT HOLDER: CURAFLO IP LLC 4035 E. OASIS STREET MESA, AZ 85215

Metal Rescue Rust Remover Technical Data

OPERATING INSTRUCTIONS

This will also provide you with the knowledge to insure long life for your Investment

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

Royal Seal Gasketed Sewer Pipe

STANDARD SPECIFICATION SECTION STEEL PIPE, FUSION-BONDED EPOXY LINED AND COATED

CA-48 TECHNICAL SPECIFICATION

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

Good Boards = Results

Finding and Fixing Leaks

NAPCA BULLETIN APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

BLACK JACK ALL WEATHER ROOF COATING

The Owners Coated Coil, Cleaning and Maintenance Service Manual.

SECTION FIRE HYDRANTS

Wecryl Waterproofing System under surfacing supplied by others

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

General Guidelines for Repairing Buried PE Potable Water Pressure Pipes

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

FIELD COATING OF STEEL PIPE AND FITTINGS INSTALLED UNDERGROUND AND IN SUBSURFACE STRUCTURES

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D.

the runnerless types of molds are explained post molding operations are described the basic methods of applied decoration methods are examined

COATING & WRAPPING OF UNDERGROUND PIPING

Asbestos WHAT TO DO? Studies of people who were exposed to high levels of asbestos in factories and shipyards, are at increased risk of:

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS

K2 STONE NATURAL VENEER

How to Build a Printed Circuit Board. Advanced Circuits Inc 2004

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION

Apr 17, 2000 LAB MANUAL

Section Four: Linings and Coatings

Technical Data Sheet February 2014

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

Profiles for floors of same height Cerfix Projoint

MASONRY RESTORATION Lime Putty Mortar Repointing Guide

Solvent Cementing Instructions For Plastic Pipe & Fittings

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

SANITARY SEWER SPECIFICATIONS

Section SEWER PIPE INSTALLATION AND TESTING

Scotch-Weld. Low-Odor Acrylic Adhesives DP810 DP810 NS. Technical Data June, 2004

RTV162. Electronic Grade Silicone Adhesive Sealant

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

TECHNICAL SPECIFICATION

PRETREATMENT TECHNICAL DATA SHEET WATER EMULSIFIABLE RUST PREVENTATIVE PRODUCT DESCRIPTION

SECTION STORM DRAIN SYSTEM

PRODUCT DATASHEET. Confidex Ironside Micro CONTENTS

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

Colorado State University. Durrell Center Roof Repair

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

XONYX Solid Surface Owner's Manual

Evaluating Protective Coatings for Ballast Tanks

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

SECTION NONREINFORCED CONCRETE SEWER PIPE

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

SECTION DUCTILE IRON PIPE AND FITTINGS

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Anode Rods, Cathodic Protection and the Porcelain (glass) Lining

Denver Water s Assessment of Interior Polyurethane Coating of 108-inch Water Pipeline John H. Bambei, Jr. 1, Neal Kelemen 2, Richard Mielke 3

City of San Diego, CWP Guidelines

How To Test A Base Axe

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

Transcription:

CAll TOll FREE 1-888-SPEC401 or E;XILq)! Standard For Lining Ductile Iron Pipe and Fittings For Sewer Service QUALIFIED UNDER ASTM E-96 ASTM G-14 ASTM G-95 ASTM D-714 ASTM B-117 ASTM D-1308 Standard Test Methods PROTECTO 401 Table of Contents I-~-Select Item Below --- ~. Protecto 401 lined ductile iron pipe and fittings provide the maximum protection and the strength necessary to do the job in tough sewer pipe applications. Protecto 401 has successfully been used in hundreds of sanitary sewer applications and has been proven with both laboratory testing and years of actual sewer service on all sizes of ductile iron pipe and fittings. The development of Protecto 401 was begun in 1979. The first ductile iron sewer pipe was lined and placed in service in 1981. Since then hundreds of miles of ductile iron sewer pipe have been lined with Protecto 401 with no lining failure. Because Protecto 401 Ceramic Epoxy Lining was designed and is used as protection for ductile iron sanitary sewer pipe, it provides the reliability of cement mortar lining with the excellent corrosion protection of novalac epoxy. This concentration of effort has resulted in performance unparalleled by other linings. Protecto 401 has been tested extensively. The Table oj ~onj~l1ts contains results of these tests and other data associated with lining for ductile iron sewer pipe. Because the specifications for application and testing of Protecto 401 Ceramic Epoxy have been developed for ductile iron pipe using test data and performance history, no deviations from the specification shall be permitted without prior written approval of the lining manufacturer. If required, third party inspection of Pro tecto 401 Ceramic Epoxy lined ductile iron pipe shall be done only after written notice to the applicator of Protecto 401 Ceramic Epoxy. Any third party inspection shall be accomplished using standard Protecto 401 Ceramic Epoxy Quality Control Procedures. Protecto 401 is applied to the interior of ductile pipe and fittings utilizing specialized application equipment and a stringent specification. The lining is designed to be applied at a nominal 40 mils thickness. A nondestructive pinhole detection test and a thickness test is performed to insure a sound, chemically resistant protective lining for ductile iron pipe and fittings. Protecto 401 is intended for use in domestic sanitary sewage lines. Chemical injection for odor control may damage pipe, gaskets, and/or protective linings and should be undertaken with extreme caution. Requests for industrial sewer applications of Pro tecto 401 lined ductile pipe and fittings should be made to a pipe marketing representative for individual recommendations.

CALL TOLL FREE 1-888-SPEC401 or E:mCiil SIMULATED SEWER ENVIRONMENT ACCELERATED TESTING OF PROTECTO 401 LINING IN PRODUCTION RUN DUCTILE IRON PIPE RESULTS No 2.0 TEST No 2.0 ASTM years other years effect D-7l4-87 effect No undercutting effect when when rated rated using scribe. using million.002 inch cycles when No (.05mm) effect ratedwhen loss using After ratedone using ed brasion Immersion WaterResistance Immersion 2.0 years No ASTM_D-=-I1A~87 undercutting D-7l4-87 Q-7J4=-87 8 P at scribe. mersion odium Acid Immersion Hydroxide 2.0 years No undercutting at scribe. -8.i Salttests Spray are currently ongoing. Back to Tal)l~_of<::Qntents CALL TOLL FREE 1-888-SPEC401 or Emi3il Logos and pictures shown are trademarks of their respective owners Copyright 2000. [Jigila/Trends CorporaliYI1

CALL TOLL FREE 1-888-SPEC401 or E.mgil GEORGE MILLS & ASSOCIATES INTERNATIONAL, INC. HOUSTON. USA. NASHVILLE P.o. Box 847 3133 Knobview Drive Humbler, TX 77347 Nashville, TN 37214 Tel: (615) 391-4785 Fax: (615) 885-9655 Tel: (713) 852-7600 Fax: (713) 852-8777 TEST METHOD: ASTM G-95: Standard Test Method for Resistance to Cathodic Disbondment by the Attached Cell Method. COATING SYSTEM: PROTECTO 401 CERAMIC EPOXY Lining: Plant applied Protecto 401 Ceramic Epoxy lined ductile iron pipe (DIP) cut into 6 inch x 6 inch coupons. PROCEDURE: Following ASTM G-95, a five inch tall by four inch diameter section of PVC pipe, ground to the approximate curvature of the internal surface of the pipe coupon, was attached via RTC silicone caulk. A 0.25 inch holiday was drilled through the coating to metal in the center of each coupon. A 0.25 inch hole was drilled through one corner of each coupon and fitted with a bolt to provide attachment of the negative lead from the impressed current cathodic protection power supply. Triplicate coupons were subjected to simulated cathodic protection by impressing a 1.5 volt potential between the metal and an electrode within the CD cell for a period ofthirty days. The electrolyte used was 3% sodium chloride in tap water. An additional set of coupons were subjected to the same test regime with the exception that they were maintained at 600C on a sand bath. The hot (60 C) cells were covered with plastic wrap to minimize evaporative losses. Evolved hydrogen was able to escape through the plastic and did not present a problem. The values given are in mm of disbondment increase in diameter from original RADIUS of holiday. Panel Number: 154 (Room Temp.) 157 (Room Temp.) 156 (Room Temp.) Increase in RADIUS: Omm Omm 0.5mm Panel Number: * 155 hot (60 C) * 158 hot (60 C) 159 hot (60 C) Increase in RADIUS: xx xx 2mm * Over heated; suffered thermal damage after leaking dry over week end. CER TIFlED Dr. George Mills

CAll TOll FREE 1-888-SPEC401 or I;.m J! GEORGE MillS & ASSOCIATES INTERNATIONAL, INC. DATE: March 14, 1994 TEST METHOD: ASTM D 1308: HOUSTON. USA. NASHVILLE P.O. Box 847 3133 Knobview Drive Humbler, TX 77347 Nashville, TN 37214 Tel: (615) 391-4785 Fax: (615) 885-9655 Tel: (713) 852-7600 Fax: (713) 852-8777 Standard Test Method for Effect of Household Chemicals on Clear and Pigmented Finishes. (Chemical Soak Test with Nine Test Solutions) COATING SYSTEM: PROTECTO 401 CERAMIC EPOXY Lining: Plant applied Protecto 401 lined ductile iron pipe (DIP) cut into 3 inch x 4 inch coupons. TEST DURATION CONDITIONS: and 1080 hours (45 days), Room temperature, panels submerged 50% to provide liquid and vapor phase testing. Coupons, cut from plant applied Protecto 401 Ceramic Epoxy lined pipe, were subjected to specific 1080 hour (45 day), 70 C partial submersion in a series of strong chemicals. The test solutions and results are tabulated below. CHEMICAL SYSTEM 3% Sulfuric Acid 10% Sulfuric Acid 5% Sodium Hydroxide 20% Sodium Hydroxide 25% Sodium Hydroxide 10% Hydrochloric Acid Gasoline Toluene DI Water Hot Water (45 day @ 76 C) RESULTS Pass: Coating unaffected; Corrosion to opposite side of metal coupon. Pass: Coating unaffected; Corrosion to opposite side of metal coupon. Pass: Coating unaffected; Heavy corrosion loss to opposite side of coupon. Pass: Coating unaffected; Some discoloration of gasoline. Pass: Coating unaffected; Some discoloration of toluene. CERTIFIED Date: 12 July 1994 Dr. George Mills Back to Certified_Outside_Testing Index I Table of Contents CAll Tall FREE 1-888-SPEC401 or Em<'ii) Logos and pictl/res shown are trademarks of their respective owners Copyright 2000. [Jigita/ Tr<'l7cL~C(JljJorati()1I

CALL TOLL FREE 1-888-SPEC401 or EDlejl Procedures for sealing cut ends and repairing field damaged areas of PROTECTO 401 lined pipe and fittings. PROTECTO 401 JOINT COMPOUND TECHNICAL DATA DESCRIPTION: A brushable novalac epoxy designed for sealing cut ends and repairs when pipes are lined with Protecto 401 Ceramic Epoxy. LIMITATIONS: This material should be used on spigots and in bell sockets only after the pipe or fitting is lined with Protecto 401 Ceramic Epoxy. Protecto Joint Compound can be used over Protecto 401 or on bare substrate. Note: Do not apply Protecto 401 over Protecto Joint Compound. SURF ACE PREP ARA TION: The surface preparation shall be equal to the specifications for the project or as outlined in the touch-up procedure. Do not apply Protecto Joint Compound over wet or frozen surfaces. DRY FILM TIDCKNESS: As outlined in specifications. APPLICATION DATA APPLICATION: Brush, roll, or airless spray. TIDNNING: Thin or clean up with Methyl Ethyl Ketone. PHYSICAL DATA: VOLATILE ORGANIC CONTENTS: < 1.40 Ibs. per gal. mixed unthinned SAFETY DATA: See individual product label for safety and health data information. Individual Material Safety Data Sheets are available upon request. CALL TOLL FREE 1-888-SPEC401 or.email Logos and pictures shown are trademarks of their respective owners Copyright 2000, {Jigiwl 7i'e",ls.COIporafioli

CAll TOll FREE 1-888-SPEC401 or!::11jc:lil Procedures for sealing cut ends and repairing field damaged areas of PROTECTO 401 lined pipe and fittings. 1. Remove burrs caused by field cutting of ends or handling damage and smooth out the edge of the lining if rough. 2. Remove all traces of oil, grease, asphalt, dust, dirt, etc. 3. Remove any damaged lining caused by field cutting operations or handling and clean any exposed metal by sanding or scraping. Sandblasting or power tool cleaning roughening is also acceptable. It is recommended that any loose lining be removed by chiseling, cutting, or scraping into well adhered lined area before patching. Be sure to overlap at least I" of lining in the area to be repaired. 4. With the area to be sealed or repaired absolutely clean and suitably roughened, apply a coat of Protecto Joint Compound using the following procedure: a. Mixing Procedure - The repair kit for Protecto 401 contains two small cans of Protecto Joint Compound. Protecto Joint Compound is a two component epoxy and the contents of the small container shall be mixed with the contents of the large container. Ifless than the full contents of each can is to be mixed, the material may be mixed using the mixing ratio printed on the labels. After Part B is added to Part A, the mixture shall be thoroughly agitated. All activated material must be used within one hour of mixing. b. Application of Material - After the material has been thoroughly mixed, it can be applied to the prepared surface by brush. Brushing is usually best due to the fact that the areas to be repaired are usually small. Practices conducive to a good coating are contained in the technical data sheet for Protecto Joint Compound. 5. It is important to coat the entire freshly cut exposed metal surface of the cut pipe end. To ensure proper sealing, overlap at least one inch of the lining with this repair material. CAll TOll FREE 1-888-SPEC401 or Email Logos and pictures shown are trademarks ofthejr Copyright 2000. I)igi/a! rrclu!lc-"'/fjoralioll respective owners

CALL TOLL FREE 1-888-SPEC401 or EmEljl GEORGE MillS & ASSOCIATES INTERNATIONAL, INC. HOUSTON. USA. NASHVILLE P.o. Box 847 3133 Knobview Drive Humbler, TX 77347 Nashville, TN 37214 Tel: (615) 391-4785 Fax: (615) 885-9655 Tel: (713) 852-7600 Fax: (713) 852-8777 TEST REPORT PROTECTO 401 CERAMIC EPOXY March 2, 1995 GM&A has completed a test program on Protecto 401 Ceramic Epoxy lined pipe coupons. The results of the completed tests are reported herein. They include the following test procedures: ASTM G-14: Standard Test Method for Impact Resistance of Pipeline Coatings (Falling Weight Test). Coating System: PROTECTO 401 CERAMIC EPOXY (Internal) Lining, Plant applied to the internal surface of ductile iron with a reported age in excess of eighteen months. The conditions of the test include the following: 48 hour minimum temperature and humidity equilibration within the lab at 73 OF(23 C). Coupons were approximately 3 x 6 inch with coating applied at a DFT of33 to 48 mils (825 to 1175 microns). The weight ofthe falling impactor was 4 pounds. Continuity was determined with a low voltage, wet sponge holiday detector per ASTM G-62. Four panels were evaluated for the test using a Gardner Model #5510 Impact Tester. Panel No: Total number of impacts: Film Thickness (mils): 1 6 37-39 2 6 39-44 3 8 4 8 33-36 45-48 * ------------------------ The impact 202 0 results 142 052 590 17 18 19 using a four (4) pound 05 weight were as follows: 16 Number of Impacts: Height of Drop, RESULTS: The average impact strength ofthe coating as tested was determined to be 72 inch pounds.

Logos and pictl/res shown are trademarks of their respective owners Copyright 2000,!.2igi/a/ji'cl/(lsC;orporo/io" CERTIFIED Date: 2 March 1995 Dr. George Mills Back to Certified Outside Testing rndex I TableoCContents CALL TOLL FREE 1-888-SPEC401 or Efllaii