ENGINEERED SOLUTIONS. A2 Liner Pipe for Trenchless Technology



Similar documents
Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

SPR PE Steel Reinforced Liner

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

DIVISION 4300 STORM DRAINAGE

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

Royal Seal Gasketed Sewer Pipe

SECTION NONREINFORCED CONCRETE SEWER PIPE

BEST PRACTICE GUIDELINES FOR CULVERT LINER SELECTION

53.03 MATERIALS FOR SEWER LINER PIPE AND FITTINGS: The following materials are approved for installation in sanitary sewer lines:

Wastewater Capital Projects Management Standard Construction Specification

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

SECTION POLYVINYL CHLORIDE (PVC) PIPE

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

Section 2100-Trenching and Tunneling

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

LS 2540 SEWER LATERALS AND INSPECTION TEES

TABLE OF CONTENTS SECTION 500 SANITARY SEWER AND FORCE MAIN

SECTION STORM DRAINAGE TABLE OF CONTENTS

SECTION STORM DRAIN SYSTEM

SECTION STORM DRAINAGE SYSTEM

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

INDEX. Sec. No. Items Page Nos.

San Antonio Water System Standard Specifications for Construction ITEM NO POINT REPAIRS AND OBSTRUCTION REMOVALS

Rehabilitating Aging Infrastructure» Sewers, Culverts & Bridges

Kimberly H. Paggioli, P.E., Vice President, Marketing and Quality Control Richard C. Turkopp, P.E., Vice President, Engineering

Flowtite Jacking Pipe

SECTION POINT REPAIRS TO SANITARY SEWERS. A. Repairs to existing sewer lines by replacing short lengths of failed pipe.

PROVIDING THE SAFE CHOICE FOR UNDERGROUND PIPE RENEWAL, INTEGRITY MANAGEMENT AND ASSET RELIABILITY

Installation of Large Diameter Buried Pipes

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

Rehabilitation Alternatives. MWEA Collection System Seminar October 1, 2009

Platte River Interceptor Slipline Rehabilitation

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

CHAPTER 6 - SANITARY SEWER

SECTION POLYVINYL CHLORIDE (PVC) PIPE

Storm Sewer Trenchless Upgrade Alternatives and Recommendations

Section SEWER PIPE INSTALLATION AND TESTING

SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD

PIPE REHABILITATION. Industrial Wastewater Municipal Wastewater Drinking Water Pressure Pipes

Repair or Replacement - Band-Aids vs. Surgery

Module 3: Sewer Material Lecture 3: Sewer Material

TECHNICAL NOTE Lining of Casings with SaniTite HP Pipe

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

SECTION 724 PIPE CULVERTS

Use of Corrugated HDPE Products

02780 LINER FOR SEWER REHABILITATION

Module 3 : Sewer Material. Lecture 3 : Sewer Material

725-R-599 PIPE LINING. (Revised ) SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING PIPE

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

SECTION 7- STORM SEWER

Section 402. STORM SEWERS

STANDARD SPECIFICATIONS SECTION INSTALLATION OF GRAVITY SEWER PIPELINES. 1. Trenching, Backfilling and Compacting: 02223

INSTALLATION OF INSITUFORM LINER

OAR52 A-1 (September, 1981)

Ultra-Rib PVC Storm Sewer Pipe 8" - 30"

HDPE PRODUCTS QUALITY, PERFORMANCE AND ECONOMY COMBINED

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

Carlon Bore-Gard and Boreable Multi-Gard Raceway

SECTION ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL

PVC Gasketed & Solvent Weld Pipe

Pipeline Replacement using Relining

Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology

TRB Webinar, Sponsored by AFS40 (Subsurface Soil-Structure Interaction), June 20 th 2008

Sewer Line Rehabilitation

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

SECTION 9.02 BUILDING SUBSURFACE DRAINS (PERIMETER, ETC.)

REVIEW OF TRENCHLESS TECHNIQUES FOR THE REHABILITATION OF SEWERS. Gerhard (Gerry) P. Muenchmeyer, P.E. Muenchmeyer Associates, LLC

SECTION 3 SANITARY SEWER DESIGN

ASTM C76, Class III, Wall B, except as modified herein. Clean natural sand, ASTM C33. Artificial or manufactured sand will not be permitted.

Ultraviolet (UV) Light Cured Fiberglass Reinforced Cured-In-Place Pipe (CIPP) It is not just for sanitary sewer rehabilitation

September 2012 Brunswick County Engineering Department Revision 1.0. Technical Specification GRAVITY SANITARY SEWER SYSTEM

SUBMITTAL 10 FEET. Cast Iron Soil Pipe Products Hubless Pipe & Fittings HUBLESS PIPE 10 FEET*

CW GRAVITY SEWERS TABLE OF CONTENTS

Pipe bursting provides viable alternative for rehab work By Greg Key, U.S. Pipe

SECTION FACILITY STORM DRAINAGE PIPING

Beacon Hill Sewer District Standard Specifications

Let Us Give Utilities the Respect that they Deserve.

SANITARY SEWER SPECIFICATIONS

SECTION PRECAST CONCRETE UTILITY STRUCTURES

Storm Sewer Pipe Material Technical Memorandum 3 rd Edition. Urban Drainage and Flood Control District. for. July 13, Project No.

Culvert Rehabilitation Practices

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 21

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY

Letty Arvide-Gomar, PE

Model Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer

SECTION GRAVITY SANITARY SEWERS

Ridgistorm-XL - the latest innovative

Session: HDPE Pipe Test Rafael Ortega, Vice President, Lockwood, Andrews & Newnam

Nebraska Department of Roads Drainage and Erosion Control Manual December 2011 Appendix C: Pipe Material Policy Page C-1 PIPE MATERIAL POLICY

Industrial Pipeline Integrity Management & Remote Polyurea Pipe Lining Systems.

Transcription:

ENGINEERED SOLUTIONS A2 Liner Pipe for Trenchless Technology

A2 Liner Pipe Restores Deteriorated Sewers Cost-Effective Rehabilitation The increasing rate of sanitary and storm sewer deterioration requires an efficient and cost-effective rehabilitation solution. Contech A2 Liner Pipe uses proven trenchless installation methods to slipline existing sewer lines without the disruptions associated with open trenching while increasing productivity and lowering costs. Proven Trenchless Installation Methods A2 Liner is Less Costly Than Cured-In-Place A2 Liner provides a tremendous cost savings over curedin-place pipe up to 50% depending on the installation. Relining with A2 Liner eliminates costly bypass operations because normal flow is maintained. Additionally, sliplining with A2 Liner gives you a new pipe with direct-bury strength of 46 psi stiffness which means it doesn t depend on the host pipe for long-term structural performance as cured-inplace liners do. Plus, the double-wall design provides extra stiffness for improved shape-control during installation and grouting. Restores Hydraulic Capacity With a Manning s n of.009, A2 Liner Pipe restores hydraulic capacity to your sewer. Its glossy-smooth interior allows the relined pipe to carry as much or more flow than the existing host pipe, even with diameter reductions (see page 3). Easy Installation Contech provides A2 Liner in 12-36 inch diameters and lengths of 10 and 20 feet. Custom lengths as short as 2.5 feet are available for installation within small insertion pits or manholes. Field installations demonstrate that workers can slipline with A2 Liner Pipe at a rate in excess of 200 feet per hour. And because it is lightweight, you can use smaller, less expensive equipment for handling and joining another savings. Joint Tightness You Can Depend On A2 Liner Pipe s patented gasketed STAB-JOINT meets the joint tightness test requirements of ASTM D3212. It is also designed to remain watertight up to 5 degrees angularity. Unlike other gasketed joints for segmental sliplining, the A2 Liner STAB-JOINT ensures a positive connection even when sliplining misaligned, obstructed or curvilinear sewers. Additionally, this joint system incorporates a PVC coupling that maintains a constant outside and inside diameter. High-Quality PVC Manufactured exclusively from low fill, cell class 12454 PVC compound the most widely accepted sewer pipe material A2 Liner Pipe provides excellent durability and resistance to abrasion. It withstands corrosive attack from both acidic and alkaline soils and is unaffected by chemicals found in normal sewage. A2 Liner Pipe s gasketed coupling allows sliplining of deteriorating pipelines without diverting the flow of the existing sewer. 2

A2 Liner Pipe Increases Hydraulic Capacity When reinforced concrete and vitrified clay pipe have offset joints, cracks, spalling or protrusions, there is greater resistance to flow, reducing hydraulic capacity. Significant hydraulic improvements are achieved when these deteriorated pipes are sliplined with A2 Liner. Its Manning s n of.009 can actually result in increased flow capacity and higher flow velocities for improved self-cleaning. The Manning equation can be used to determine the flow capacities for circular pipes before and after rehabilitation with A2 Liner Pipe: 8/3 n existing D A2 Liner % Existing Flow = n A2 Liner D existing Table 1 compares the flow of existing concrete pipe after it is relined with A2 Liner Pipe, in which: n = Manning s coefficient: A2 Liner n =.009 Existing RCP n = 0.015 D = inside diameter This analysis is based upon closed-system flow for sewers or outlet-controlled flow for culverts. Table 1 Hydraulic Comparisons Existing Vs. Relined Pipe Existing A2 Liner Percent Diameter Diameter Existing (Inches) (Inches) Flow* 15 12 92 18 15 103 21 18 111 24 21 117 27 24 122 30 27 126 36 30 103 42 36 111 * Sliplining with A2 Liner can actually increase the hydraulic capacity of exist RCP drainage systems 3

Installation Procedures Sliplining Considerations Inspect and clean the existing pipeline and verify the liner clearance prior to sliplining. Remove any obstructions, protrusions, joint offsets, debris, out-of-roundness or other irregularities that could damage or prohibit passage of the liner pipe. Install the liner pipe by either pushing or pulling it through the existing pipe. The leading pipe spigot end is usually fitted with a nose cone to help the liner pipe ride over small joint misalignments and other small obstructions or inconsistencies in the existing host pipe. The pipe jacking/pushing loads should be monitored. Excessive force could telescope pipe joints or damage the liner pipe. The safe compressive/jacking loads for A2 Liner Pipe are listed in Table 2. The pushing distances shown are based on the following: - Dry conditions - Unobstructed, clear, straight pushing/pulling - Coefficient of sliding friction 0.75 When required, service reconnections can be accomplished by small point repairs using PVC tapping saddles or INSERTATEE fittings. The annular space between the liner pipe and the host pipe is usually filled with cement or cellular grout, depending on site conditions. Low-strength grouts (150-1,000 psi compressive strength) are typically used. Table 2: Safe Compressive/Jacking Loads and Pushing Distances for A2 Liner Pipe Pipe Safe Compressive Unobstructed Diameter Jacking Loads Pushing Distances (Inches) (Pounds) (Feet) 12 3,200 1,000 15 9,100 1,250 18 14,000 1,250 21 19,000 1,250 24 23,830 1,250 27 27,760 1,250 30 30,900 1,250 36 37,000 1,500 * For straight pushing of A2 Liner Pipe ** Greater pushing/pulling distances are possible depending on site conditions Additional installation instructions can be found in the Instructions for Unloading, Handling and Installing Contech A2 Liner Pipe booklet available from your local Contech representative. Existing Pipe Wall A2 Liner Pipe A2 Sleeve Connector Nose Cone Push Push Ring Existing Pipe Wall A2 liner Pipe insertion detail 4

A2 Liner Pipe Rapidly Renovates Culverts In addition to repairing sanitary and storm sewers, A2 Liner Pipe s design features make it the obvious choice for relining distressed culverts. The corrugated exterior design provides high strength and high stiffness without the additional weight of solid wall pipe alternatives. A2 Liner s lightweight design, coupled with a unique gasketed STAB-JOINT, makes joining easy. Lubricant, two chains and one or two come-alongs are usually all that is required to join sections. The light, easy-to-handle sections allow for maneuvering in tight workspaces. They can be installed either manually or with assistance from a backhoe. In most cases, a small crew with minimal equipment can reline at a fraction of the time and expense of replacement. And because pavement cuts are usually eliminated, traffic disruption in congested areas and the potential for future pavement settlement is minimized. Small crews and minimal equipment required 5

Product Details 20 or 10 Standard Laying Length A2 Liner Pipe is available in standard lengths of 10 and 20 feet. 2.5-feet lengths are available for insertion via manholes. Inserta-Tee Fitting Table 3 A2 Liner Pipe Sizes & Dimensions Nominal Average Average Diameter O.D. I.D. (Inches) (Inches) (Inches) 12 12.8 11.7 15 15.7 14.3 18 19.2 17.6 21 22.6 20.7 24 25.6 23.5 27 28.9 26.4 30 32.2 29.5 36 38.7 35.5 Saddle-Tee Fitting Either INSERTATEE or saddle tee fittings allow easy-to-make connections for A2 Liner Pipe. Saddle tee fittings employ stainless steel fasteners. A2 Liner Pipe s patented STAB-JOINT coupler fits flush with the outer wall surface for easy insertion. 6

PVC Corrugated Sewer Pipe with a Smooth Interior for Sliplining Installation PART I General: 1.01 PVC Profile Wall Sewer Pipe This specification covers PVC Corrugated Sewer Pipe With a Smooth Interior for Sliplining Applications. 1.02 References A. ASTM F949 Standard Specification for Poly (Vinyl Chloride) (PVC) Corrugated Sewer Pipe With a Smooth Interior and Fittings. B. ASTM D3212 Standard Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals. C. ASTM D1784 Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds. D. ASTM D2412 Standard Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading. E. ASTM F477 Standard Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe. F. ASTM D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings. 3.03 Specifications The specifications contained herein govern, unless otherwise agreed upon between purchaser and manufacturer. PART 2 Products 2.01 Materials A. PVC Compound: Pipe and fittings shall be made of PVC compound having a minimum cell classification of 12454 in accordance with ASTM D1784. Additional fillers (such as calcium carbonate for modulus enhancement) that lower the tensile strength of the compound and change the minimum cell classification shall not be allowed. B. Elastomeric Gaskets: Gaskets shall meet the requirements of ASTM F477 and be suitable for the service intended. 2.02 Manufacture and Construction A. Pipe: Pipe shall be manufactured as a single extrusion of the smooth inner and the corrugated outer walls. The corrugated exterior profile shall be annular and seamless. B. Joints: Pipe shall be field connected with molded or fabricated PVC couplings. Couplings shall not increase the outside diameter or reduce the inside diameter when assembled. The joint shall utilize elastomeric sealing gaskets as the sole means to maintain joint water tightness and shall meet the requirements of ASTM D3212. C. Fittings: Couplings, elbows, reducers, tees, wyes, laterals and other fittings shall be capable of withstanding all operating conditions when installed. They may be molded or fabricated. D. Manufacturer: The acceptable manufacturer shall be Contech Engineered Solutions INC. 2.03 Dimensions A. Diameters: The actual outside diameters of the pipe barrel for 12-36 nominal diameters shall be in accordance with ASTM F949. B. Lengths: Pipe shall be supplied in nominal lengths of 10 or 20 feet. When required by radius curves, pit size or sewer misalignment, etc., pipe shall be supplied in special lengths that are an even division of 20 feet. The minimum laying length shall be 2.5 feet. C. Wall Thickness: The minimum wall thickness shall be as stated in Table 1of ASTM F949 when measured in accordance with ASTM D2122. D. Sockets: All socket (bell) dimensions shall be sufficiently deep to allow for maximum joint angularity without joint separation. The minimum socket depth shall be 4.25 inches. The outside diameter of sockets shall be equal to the pipe outside diameter. 2.04 Testing A. Pipes: Pipes shall be manufactured and tested in accordance with ASTM F949. B. Joints: Joints shall meet the requirements of ASTM D3212 and shall remain watertight at 5 degrees angularity. C. Stiffness: The minimum pipe stiffness shall be 46 psi when tested in accordance with ASTM D2412. 2.05 Owner Inspection A. The owner or other designated representative shall be entitled to inspect pipes or witness the pipe manufacturing. 2.06 Packaging, Handling and Shipping A. Packaging, handling and shipping shall be performed in accordance with the manufacturer s instructions. PART 3 Execution 3.01 Installation A. Unloading, Handling and Installation: Unloading, handling and installation of pipe and fittings shall be in accordance with the project plans and spec and the manufacturer s requirements booklet: Instructions for Unloading, Handling and Installing Contech A2 Liner Pipe. B. Pipe Grouting: Annular space grouting shall be in accordance with project plans and specs and the manufacturer s requirements. The grouting shall not damage the pipe liner. C. Acceptance: Acceptance of the installed liner shall be based on a video taped inspection after installation to assure that all joints are properly assembled and that no damage exists. 7

Contech Engineered Solutions provides site solutions for the civil engineering industry. Contech s portfolio includes bridges, drainage, retaining walls, sanitary sewer, stormwater, erosion control and soil stabilization products. For more information, call one of Contech s Regional Offices located in the following cities: Ohio (Corporate Office) 513-645-7000 California (Long Beach) 562-733-0733 Colorado (Denver) 720-587-2700 Florida (Tampa) 727-544-8811 Maine (Scarborough) 207-885-9830 Maryland (Baltimore) 410-740-8490 Oregon (Portland) 503-258-3180 Texas (Dallas) 972-590-2000 Visit our web site: www.conteches.com 800.338.1122 NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS AN EXPRESSED WARRANTY OR AN IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. SEE THE Contech STANDARD CONDITIONS OF SALE (VIEWABLE AT WWW.ContechES. COM/COS) FOR MORE INFORMATION. A2Liner 3K 2/13 IH RECYCLED PAPER ENGINEERED SOLUTIONS 2013 Contech Engineered Solutions LLC All rights reserved. Printed in USA.