R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.



Similar documents
The Possibilities Tomosynthesis Brings to Lung Cancer Screening

Clinical Applications to Orthopaedics by New X-ray Technology

INTRODUCTION. A. Purpose

Patient Exposure Doses During Diagnostic Radiography

Multi-slice Helical CT Scanning of the Chest

College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries

R/F. Applications and Present Issues of Tomosynthesis in Spine Surgery. 87th Annual Meeting of the Japanese Orthopaedic Association Evening Seminar 4

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

Performance testing for Precision 500D Classical R/F System

RAD. The Effect on Work Efficiency of Using a General Radiography System Equipped with FPDs. 1. Introduction. Hidenori Otake, Naomi Ogawa

Quality Assurance. The selection of the equipment. Equipment Specifications. Medical Exposure Directive 97/43 Euratom. Quality Assurance Programme

Mammography. What is Mammography?

Low-dose CT Imaging. Edgar Fearnow, M.D. Section Chief, Computed Tomography, Lancaster General Hospital

Development of SCENARIA New Version Software MEDIX VOL. 62 P.32 P.35

2/28/2011. MIPPA overview and CMS requirements. CT accreditation. Today s agenda. About MIPPA. Computed Tomography

X-ray (Radiography) - Chest

Development of High Speed Oblique X-ray CT System for Printed Circuit Board


SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM

kv-& MV-CBCT Imaging for Daily Localization: Commissioning, QA, Clinical Use, & Limitations

Irradiation Field Size: 5cmX5cm 10cmX10cm 15cmX15cm 20cmX20cm. Focus-Surface Distance: 100cm. 20cm Volume of Ion Chamber : 1cmX1cmX1cm

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

Digital Dental X-ray. Midmark Animal Health Products

High-quality/High-resolution Digital Ultrasound Diagnostic Scanner

Fundamentals of Cone-Beam CT Imaging

Application of Digital Radiography for the Detection and Classification of Pneumoconiosis

Easy Quality Control with - PTW Equipment. Code of Practice - Quality control of X-ray equipment in diagnostic radiology

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging

Digital Breast Tomosynthesis QC Requirements

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

DENTAL Cone beam 3D X-RAY SYSTEM with

The Whys, Hows and Whats of the Noise Power Spectrum. Helge Pettersen, Haukeland University Hospital, NO

X-RAY IMAGING Emerging Digital Technology - CMOS Detectors

Development of High-sensitivity and High-resolution Digital Mammography System AMULET

IGRT. IGRT can increase the accuracy by locating the target volume before and during the treatment.

Surgery Support System as a Surgeon s Advanced Hand and Eye

American College of Radiology CT Accreditation Program. Testing Instructions

Purchasing a cardiac CT scanner: What the radiologist needs to know

The American College of Radiology Stereotactic Breast Biopsy Accreditation Program: Frequently Asked Questions (Updated: August 24, 2015)

I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit

Name: Date: Team: Lab Experiment # 3. Focused Grid Positioning Errors. Computed Radiography and Direct Digital Radiography

3D Accuitomo FPD XYZ Slice View Tomograph. Super-High Resolution Images of Region of Interest

X-ray (Radiography), Chest

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

Concepts for High-Resolution Low-Dose CT of the Breast

GE Healthcare. Revolution EVO. More than just high tech. Higher purpose.

CBCT for Prone Breast. Todd Jenkins, MS, DABR Nash Cancer Treatment Center

Radiation Safety Issues for Radiologic Technologists

Manual for simulation of EB processing. Software ModeRTL

QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions

Image Quality and Radiation Dose for Intraoral Radiography: Hand-Held Held (Nomad), Battery Powered

Spiral CT: Single and Multiple Detector Systems. AAPM Refresher Course Nashville, TN July 28,1999

Digital Mammography Update: Design and Characteristics of Current Systems

I.7. SOFT TECHNIQUE STILL IN USE IN CHEST RADIOGRAPHY PROS AND CONS

Chest CT protocols. Mannudeep K. Kalra, MD, DNB. Dianna D. Cody, PhD. Massachusetts General Hospital Harvard Medical School

Checklist for the Qualification of Digital Detector Array Systems

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

Computed Tomography Resolution Enhancement by Integrating High-Resolution 2D X-Ray Images into the CT reconstruction

NORMAL CHEST RADIOGRAPHY. Front and lateral view

Low-dose CT for Pulmonary Embolism

Society of Nuclear Medicine 1850 Samuel Morse Drive Reston, VA

Comparing dose and image quality of a conventional 400 speed class film/screen system with a CR system by assessing pediatric chest examinations

Veraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.

Tracking Radiation Exposure From Medical Diagnostic Procedures: Siemens Perspectives

Pediatric Hospitals Bring Low-dose CT to the Middle East

Lung Cancer. This reference summary will help you better understand lung cancer and the treatment options that are available.

Moving Forward What does this mean for the Medical Physicist and the Imaging Community?

Administrative. Patient name Date compare with previous Position markers R-L, upright, supine Technical quality

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

Monte Carlo simulation of a scanning whole body counter and the effect of BOMAB phantom size on the calibration.

Patient Prep Information

Case Number: RT (M) Potential Audiences: Intent Doctor, Oncology Special Nurse, Resident Doctor

The Aged Lung per se and Chronic Pulmonary Diseases in and around the Aged Lung

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

WHERE IN THE WORLD JILL LIPOTI?

X-ray (Radiography) - Abdomen

Quality Control of Full Field Digital Mammography Units

BARE PCB INSPECTION BY MEAN OF ECT TECHNIQUE WITH SPIN-VALVE GMR SENSOR

5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

RICHARD T ELL ASSOCIATES,INC.

Standard Test Method for Classification of Film Systems for Industrial Radiography 1

QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET

State-of-the-Art Technology in Cardiac CT

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Quality control of CT systems by automated monitoring of key performance indicators: a two-year study

Archimedes Palimpsest Metadata Standard XRF Extensions DRAFT

General Information About Non-Small Cell Lung Cancer

SWABIK Project. Software Tools for DICOM Media Exchange in Clinical Research: the. SWABIK Project

A Patient s Guide to the Calypso System for Breast Cancer Treatment

Radiologic Technology Training Program

Medicare Part B. Mammograms - Updated Billing Guide for Screening and Diagnostic Tests

Intensity-Modulated Radiation Therapy (IMRT)

By Anne C. Travis, M.D., M.Sc. and John R. Saltzman, M.D., FACG Brigham and Women's Hospital Harvard Medical School Boston, MA

The Fundamentals of MTF, Wiener Spectra, and DQE. Motivation

Transcription:

R/F Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening Department of Radiology, National Cancer Center Hospital East Kaoru Shimizu Ms. Kaoru Shimizu 1. Introduction 3. Utility of Chest Tomosynthesis The National Cancer Center Hospital East introduced a Shimadzu SONIALVISION safire R/F System with direct-conversion FPD that is mainly used for gastrointestinal examinations. This system incorporates a tomosynthesis function that allows the attending physician to take chest tomosynthesis images when required. Since November 2008, Dr. Moriyama of the Research Center for Cancer Prevention and Screening, National Cancer Center Hospital, and the Division of Thoracic Oncology and the Department of Radiology at this hospital have been undertaking joint research and development with Shimadzu Corporation into the utility of chest tomosynthesis for lung cancer screening and to investigate the optimal radiography conditions to reduce exposure dose. This paper reports on the results of research into reducing exposure dose, which is an important topic for screening. A feature of tomosynthesis is that it reduces the shadows of ribs and collar bones, giving superior visibility of lesions that are difficult to recognize in general chest radiography images (Fig. 1). In clinical image interpretation tests by doctors, tomosynthesis is superior to general chest radiography in terms of sensitivity, specificity, and FROC analysis. At the Joint Industrial-Academic Seminar in JRC2009, Mr. Ikeno (formerly at the National Cancer Center Hospital East) reported that when imaging was performed on a lung cancer screening CT (LSCT) phantom under low-dose CT screening conditions, the simulated tumors simulating ground-glass opacity could be detected down to 6 mm in the left lung, and that tomosynthesis achieves equivalent visibility to low-dose CT but at a lower exposure dose. Therefore, tomosynthesis is thought to offer utility to pick up lung lesions to be treated for lung cancer screening. 2. Lung Cancer Screening Lung cancer is the major cause of cancer deaths in Japan. Screening plays an important role in the early detection and treatment of lung cancer, which has a significant effect on the prognosis. Currently, general chest radiography is widely used as a simple method that offers low exposure dose. However, it can be difficult to recognize shadows in the lung field due to superimposed images of ribs, collar bone, heart, or liver. Recently, the utility of lung cancer screening using low-dose CT has been reported. However, the exposure dose is greater than for a general chest radiography and the higher detection capacity for abnormal shadows leads to concerns about the possibility of over-diagnosis. (c) Fig. 1 Comparison of General Chest Radiography, Tomosynthesis, and CT Images General Chest Radiography Image, Tomosynthesis Image, (c) CT Image

4. Efforts to Reduce Exposure Dose 4.1 Background and Aims When tomosynthesis is used for lung cancer screening, it must provide images of high diagnostic capacity at a low exposure dose, as the subjects are healthy individuals. SONIALVISION safire increases the analog gain (AG) of the amplifier that amplifies the signals output from the flat panel detector (FPD) to reduce the exposure dose for radiography. Conventional chest tomosynthesis images offer satisfactory graininess, even in high-absorption areas such as the heart and liver, and achieve further reductions in exposure dose with respect to image quality. We investigated increasing the FPD gain to reduce the exposure dose without diminishing the conventional lesion visibility. 4.2 Equipment Shimadzu SONIALVISION safire R/F System Model 9015 Thimble Chamber Dosimeter / Plane Parallel Chamber Dosimeter (Toyo Medic) Burger phantom (Kyoto Kagaku Co., Ltd.) LSCT-001 phantom (Kyoto Kagaku Co., Ltd.) Acrylic sheet (40 cm 40 cm 1 cm) 4.3 Investigation Method and Items 4.3.1 Calculation of Optimal Dose with Respect to Analog Gain (AG) The 10 cm-thick acrylic sheet was imaged using settings AG 3 (conventional), AG 10, 20, and 30. The exposure dose that achieves an equal FPD output digital value at each setting was determined and used as the optimal dose. A 10 cm-thick acrylic sheet was used to model chest radiography. The other conditions were fixed and common for all investigated items. Table 1 shows the radiography, imaging, and reconstruction conditions. X-ray tube voltage Resolution Matrix size Tomography speed Tomography angle 40 Reconstruction method 120 kv High Resolution mode Number of frames captured: 74 1440 1440 (17 inch) Slow mode Exposure time: 5.0 sec FBP method Reconstruction function: Thickness++ Table 1 Radiography, Imaging, and Reconstruction Conditions 4.3.2 Graininess Measurement The 10 cm-thick acrylic sheet was mounted, the AG was set to AG 3, 10, 20, and 30, and radiography performed at the optimal dose for each setting. The noise power spectrum (NPS) was calculated on the tomographic plane at five points (center and four corners of the image). 4.3.3 Contrast Noise Ratio Calculation A burger phantom was placed between acrylic sheets and images taken at the optimal dose using the settings AG 3 to AG 30. The ROI was set on the signal areas and background of the image obtained, and the contrast noise ratio (CNR) calculated using the expression below. CNR = (signal mean pixel value) - (background mean pixel value) / background standard deviation 4.3.4 Absorbed Dose Measurement and Visual Evaluation of Simulated Tumor A dosimeter was positioned at the center and surface of the LSCT phantom, the AG was set to AG 3, 10, 20, and 30, and radiography performed at the optimal dose. The absorbed dose measurements were performed by CT at the level of the bifurcation of trachea. Visual evaluation was performed on the 6, 8, and 10 mm-diameter simulated tumors with CT = 270 HU near the left lung apex and left diaphragm of the LSCT phantom. 4.3.5 Visual Evaluation of Images of Volunteers Radiography was performed on approximately 20 volunteers at the optimal dose with the AG set to AG 3 and 30. The images were visually evaluated for graininess in the lung field by three physicians from the Respiratory Disease Division and five X-ray technologists from the Radiology Division at this hospital. 4.4 Results 4.4.1 Calculation of Optimal Dose with Respect to Analog Gain (AG) Table 2 shows the calculated optimal dose with respect to the analog gain (AG). The values in Table 2 are the dose per frame (fixed). The dose decreases as AG increases. Gain (AG) 3 (conventional) kv ma msec mas Absorbed dose at phantom surface (mgy) Absorbed dose at phantom center (mgy) 120 160 3.2 0.51 4.2 1.2 10 120 80 1.6 0.13 1.5 0.42 20 120 25 1.6 0.04 0.71 0.21 30 120 10 1.4 0.014 0.55 0.14 (Reference) General chest radiography: 140 kv, 5 mas 0.22 0.09 CT (scanning): 120 kv, 30 ma, 0.5 s/rot (Aquilion64) 2.05 Mean value in CR at each facility: 0.28 mgy (The Grasp of Patient Exposure in CR) Japanese Journal of Radiological Technology Vol. 61 No. 11 1510-1520 2005 Table 2 Optimal Dose with Respect to AG and Absorbed Dose Measurements

4.4.2 Graininess Measurement Fig. 2 shows the measured noise power spectrum (NPS) results. The horizontal axis represents the spatial frequency (lp/mm) and the vertical axis represents the NPS value. The Nyquist frequency is 1.7 lp/mm. The most satisfactory image graininess was obtained at AG 3. As AG increases, the exposure dose decreases, resulting in deterioration in graininess. No positional dependence was observed. the permitted range to ensure a level of image quality that does not impair diagnosis. The results are shown below. Fig. 3 Calculated CNR Value at Each AG Value Fig. 2 NPS Measurement Results at Each AG Value 4.4.3 Contrast Noise Ratio Calculation Fig. 3 shows the calculated contrast noise ratio (CNR) results. The horizontal axis represents the analog gain (AG) and the vertical axis represents the CNR value. The image obtained at AG 3 exhibited the highest contrast noise ratio (CNR) but the CNR values decreased as the AG value increased (i.e., as the exposure dose decreased). Physical evaluations were previously conducted, including graininess measurements and CNR calculations. Next, the following visual evaluations were performed to evaluate what low-dose radiography lies within 4.4.4 Absorbed Dose Measurement and Visual Evaluation of Simulated Tumors Table 2 shows the measured absorbed doses at the phantom center and surface. The absorbed dose at the phantom center and surface exhibit the same trends with respect to the analog gain (AG): the absorbed dose decreases as AG increases. The 6, 8, and 10 mm-diameter simulated tumors near the lung apex in the images obtained at AG 3 revealed that AG 10 and AG 20 achieved equivalent visibility to the AG 3 images. Graininess was poor in the AG 30 image. The 6 mm-diameter simulated tumor, in particular, is hidden by noise and is barely visible. Equivalent visibility was achieved from AG 3 to AG 20 for the 6, 8, and 10 mm-diameter simulated tumors near the diaphragm, similar to the tumors near the lung apex. However, the 6 and 8 mm-diameter simulated tumors in the images obtained at AG 30 are hidden by noise and are difficult to recognize (Fig. 4). (c) (d) Fig. 4 Visual Evaluation of Simulated Tumors near the Diaphragm AG 3, AG 10, (c) AG 20, (d) AG 30

The absorbed dose at the phantom surface at AG 3, 10, 20, and 30 was 4.2, 1.5, 0.71, and 0.55 mgy, respectively. 4.4.5 Visual Evaluation of Images of Volunteers As previous evaluations indicated that the lesion visibility obtained at AG 3 can be maintained at low dose levels down to AG 20, the analog gain was set to AG 3 and AG 20 for radiography of volunteers. Compared to AG 3, the images obtained at AG 20 maintained the graininess in the lung field (Fig. 5), but with slightly inferior graininess in high absorption areas such as the heart, liver, and vertebra, and achieved equivalent visibility to the AG 3 images (Fig. 6). 4.5 Discussion We investigated increasing the FPD gain to reduce the exposure dose in chest tomosynthesis for lung cancer screening applications. As tomosynthesis sums the captured projected images to obtain arbitrary tomographic images, it is said that each projected image does not have to be taken at an adequate exposure dose. For Fig. 5 Visibility of Volunteer Images AG 3, AG 20 Fig. 6 Visibility of Volunteer Images (with Nodular Shadows) AG 3, AG 20 conventional tomosynthesis, the analog gain is set to AG 3 and the exposure dose per frame is determined according to the patient's body thickness. This study allows a lower minimum exposure dose per frame to be set by increasing the FPD gain. However, excessively low-dose radiography results in poorer graininess and lower CNR, which affects the visual evaluation. When CNR decreases, the contrast between the signal areas and background of the images obtained at each AG remains approximately constant, but poorer graininess occurs in low-dose radiography. Consequently, in addition to improving the graininess, we wondered if investigating the X-ray tube voltage with respect to the subject contrast would lead to improved CNR, that is, to greater visibility of faint shadow images. The visibility of all the simulated tumors near the lung apex and diaphragm was approximately identical in AG 10 and AG 20 low-dose radiography as in conventional AG 3 images. While poor graininess is unavoidable with low-dose radiography in high-absorption areas such as the heart and liver, the high X-ray transmittance of the lung field is thought to maintain good graininess and high visibility of the simulated tumors.

However, poor graininess in the lung field on the AG 30 low-dose radiography particularly makes the 6 and 8 mm-diameter simulated tumors near the diaphragm impossible to recognize. This occurs not only due to the low-dose radiography, but due to noise effects related to the position of the simulated tumors next to high-absorption organs. Such differences in lesion visibility according to the position due to reduced exposure dose are unacceptable. From the results above, an analog gain (AG) of AG 20 is thought to be appropriate to reduce the exposure dose while maintaining the original lesion visibility. This AG permits a significant 83 % reduction in the patient's skin dose, from the conventional 4.2 mgy to 0.71 mgy. In contrast with the conventional radiography settings of 120 kv, 160 ma, and 3.2 ms (per frame, fixed), imaging with consideration of the body thickness is currently performed based on 120 kv, 25 ma, and 1.6 ms with an AG 20 setting. References 1) Naoya Ikeno:Technical Evaluation of Tomosynthesis Performed with SONIALVISION safire, MEDICAL NOW 66, 8-10 (2009) 2) Noriyuki Moriyama: Clinical Utility of Tomosynthesis in Chest Cancer Diagnosis," MEDICAL NOW 66, 11-13 (2009) 3) Naoya Ikeno: Experience of Using SONIALVISION safire - Basic Evaluation of RSM-DSA and Tomosynthesis in Relation to Examinations of Digestive Tract, MEDICAL NOW 61, 18-22 (2007) 4) Hiroshi Hirano: Utility of Tomosynthesis with a Flat-panel Detector - Comparison with MSCT," MEDICAL NOW 57, 16-23 (2005) 5) Koichi Shibata "Development of Clinical Application Techniques of the Direct-conversion FPD, Japanese Journal of Radiological Technology 62 (7), 906-912 (2006) 5. Conclusions Increasing the FPD gain can significantly reduce the exposure dose. In the future, functions to automatically set radiography conditions from the patient's body thickness are desirable to further reduce the exposure dose. Tomosynthesis is a simple procedure that significantly enhances lesion visibility at approximately 2.4 times the exposure dose of a general chest radiography. It achieves detection equivalent to low-dose CT but at just one-tenth the exposure dose. Tomosynthesis could become a new modality for lung cancer screening to pick up lung lesions to be treated. In the future, we wish to make overall investigations of the radiography conditions, additional filter selection, and image processing to further reduce the exposure dose and enhance image quality.