LG Electronics AE Company, Commercial Air Conditioning



Similar documents
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Daikin Altherma hybrid heat pump. The natural combination

york air-conditioning products Residential & VRF News 2015

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

Natural geothermal energy.

ECOCIAT. Domestic hot water heat recovery unit

Hybrid heat pumps. saving energy and reducing carbon emissions

Daikin Altherma. hybrid heat pump. The natural combination

The natural ombination

AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS

AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS

ROTEX gas hybrid heat pump. A strong team.

Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: Fax:

Cooling kw Heating kw

Hot Water. Heat pump water heaters. Residential and Commercial R410a

HP switch LP switch Discharge thermo Comp. Surface thermo

Daikin Altherma Hybrid Heat Pump

The natural ombination

Create the right atmosphere with renewables.

Daikin Altherma Hybrid Heat Pump

Versati Air to Water Heat Pump

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

HUB RADIATOR HYBRID. Multi-energy hybrid system to produce heating and DHW. Multi-energy hybrid system to produce heating, cooling and DHW

Delivering exceptional performance and Ecovalue. Ecocent

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

Hot Water Heat Pump Catalogue

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

Appendix - Controllers 179

Chiller/Heat pumps 30AWH. Reversible. Monobloc inverter

FULL DC INVERTER SYSTEMS

CRAC Precision climate control units for data centres

Combi Unit Genius. The energy efficient Building Service Centre

Daikin Altherma Hybrid Heat Pump

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Inverter Air Conditioning for Light Commercial Use

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

News in Data Center Cooling

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

HEAVY DUTY STORAGE GAS

Energy Efficiency HOSPITALITY.

Building Energy Systems. - HVAC: Heating, Distribution -

PRODUCT CATALOG. Indoor Units

Heating when you need it Cooling when you don t. NIBE SPLIT Air/water heat pump

Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and

Commercial Hot Water. Make a difference...

How To Make A High Efficiency Thermostat

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

New technical solutions for energy efficient buildings

Renewable Heat Pumps. A guide for the technically minded

HVAC Systems: Overview

Air-cooled Chillers with High Speed Centrifugal Compressors

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

Session 2: Hot Water Supply

Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

AIR CONDITIONER SERVICE MANUAL. Please read this manual carefully before operating your set and retain it for future reference. System.

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

Air conditioners Heating & Cooling

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

HIGH-EFFICIENCY CO 2 HEAT PUMP WATER HEATER SYSTEMS FOR RESIDENTIAL AND NON-RESIDENTIAL BUILDINGS

Multi Air Conditioner SVC MANUAL(Exploded View)

Celxia. a s. Artcool uses state-of-the art technology to assure customer satisfaction.

Air-to-water heat pumps: Making the most of renewables. Richard Pickford, Daikin UK

GREE, MAKING BETTER AIR CONDITIONERS

Chapter 3.4: HVAC & Refrigeration System

Sea Water Heat Pump Project

Glossary of Heating, Ventilation and Air Conditioning Terms

SOLEL SUNCOOLER SOLAR-POWERED AIR-CONDITIONING / HEATING SYSTEM

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

DAikin Altherma low temperature heat pump. end user leaflet

CHAPTER CONTENT PAGE. Hybrid: The perfect solution for all systems. Explanation of the - Heat Exchanger 4. Finishes 12

Waste Heat Recovery through Air Conditioning System

ALFEA HYBRID DUO GAZ. New Model 2011

Nordic Heat Pump Product Guide

HVAC Processes. Lecture 7

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

GEOTHERMAL HEATING AND COOLING INTRODUCTION

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

NEW 3-PIPE ECOi MF2 SERIES

Ecodan Air Source Heat Pump and Flow Temperature Controller 2

The heat is there let s use it! Using free environmental heat from the air with heat pump technology for central heating and domestic hot water

ZUBA-CENTRALTM. Heating & Cooling. Evolved. HEATING AND AIR CONDITIONING FOR WHOLE-HOME, YEAR-ROUND COMFORT

Life s Good! What is LG?

Vitocaldens 222-F Compact Gas-Hybrid appliance

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

DUCTED AIR CONDITIONING SOLUTIONS

How Ground/Water Source Heat Pumps Work

Direct Fresh Air Free Cooling of Data Centres

Study on Performance Evaluation of a Split Air Conditioning System Under the Actual Conditions

HVAC Basic Science - System Capacity

Theta Dual service BFC, SGE, SGS for 20/30/40 kw heating capacity

Condensing Boiler Efficiency

Transcription:

www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu, Yeouido P.O.Box 335 Seoul, 15721, Korea. Phone : +82237777586 www.lg.com www.lgeaircon.com Copyright 212 LG Electronics. All rights reserved. Distributed by LG Hydro Kit is total HVAC solution that is applied to water Heating, Domestic hot water supply as well as AirConditioning by connecting various heat pump outdoor unit.

Ecofriendly, highefficiency, energy saving, recovery based heating system Control more than just the temperature with our EcoFriendly Heat Pump. The Hydro Kit LG new Hydro Kit is a highefficiency total solution for floor heating and cooling and hot water supply. This energy saving heating system takes advantage of ambient air temperatures and residual heat from other areas of the building through airtowater heat exchange to produce domestic hot water for various applications. Ideal for providing hot water supply to commercial buildings in an energyefficient way, the Hydro Kit has minimized energy costs as compared to a boiler, while achieving a considerable reduction of CO2 emissions. Heating Domestic Supply InFloor Heating with InFloor Cooling with Cold Water Cold Water Cooling LG presents a solution that will satisfy your building s water heating needs, raising temperatures without adding to the bottom line. Ecofriendly with lower CO 2 emissions Compared to fossilfuel boiler systems, the Hydro Kit emits far less CO2. Providing sustainable operation for space heating and domestic hot water using ambient air, a renewable energy source, the Hydro Kit has achieved a considerable reduction of CO2 emissions using as little as 3% of that of a gas boiler. Thanks to the refrigerant used, () that has a Zero Ozone Depleting Potential (ODP), LG contributes to ozone protection. Energy savings thanks to a highefficiency compressor Because our systems extract thermal energy from the ambient air or residual heat from cooling operations, they are far more energy efficient than comparable boiler systems. The Hydro Kit advanced heat pump technology and highefficiency compressor can optimize operations according to heating loads to increase reliability, reduce noise levels and save energy while achieving flow temperatures up to 8ºC. The heat pump works much more efficiently and conserves more energy than a traditional heating system based on fossil fuels or electricity to reduce running costs and carbon emissions. It also avoids the inconvenience of installing gas boilers and meters as well as their related maintenance costs, all while attaining a significantly higher Coefficient of Performance (COP) when compared to boiler. [A heat pump s efficiency is measured in COP (Coefficient of Performance) for heating and EER (Energy efficiency ratio) for cooling.] LG MULTI V Hydoro Kit achives COP of up to 4.2(with MULTI V Water II), meaning one unit of consumed energy yields 4 units of heated or cooled energy. Recovery heating system how to grab hot water from the air The heat pump contained in the Hydro Kit works by extracting heat from ambient air and upgrading it to heat a building or provide domestic hot water which means that heat can be recovered and reused. This ensures less energy wastage. The heat recovery aspect of the Hydro Kit goes beyond to make use of wasted heat, extracted from other areas of the building requiring cooling. This allows the heat gathered from within a building s infrastructure to be collected and stored, ready for use as hot water or heating. Taking full advantage of this, the Hydro Kit recovers and reuses the heat, which ensuresless energy wastage resulting in greater energy efficiency, reduced running costs and a reduction in carbon emissions. Tapping into renewable energy sources, that s LG smart! Hydro Kit for Multi V A complete HVAC solution Combining efficiency and total comfort, the addition of an LG Hydro Kit to an LG Multi V system provides a total heating and cooling solution for a range of applications. Providing hot water supply to these applications is adding a booster unit to the existing air conditioning systems. The easy to install compact modular structure becomes an allinone global solution for heating, cooling, ventilation and sanitary hot water. By linking the LG Hydro Kit and LG Multi V, excess heat can be successfully reused for the generation and storage of domestic hot water as well as for heating, via underfloor circuits, fan coil units and radiators. The energy savings appear any time during the year when a room needs to be cooled down. Typically, during summer, the system will use heat extracted from the indoor units to produce sanitary hot water. LG environmentally minded for a comfortable environment.

What is Hydro Kit? Hydro Kit Benefits Hydro Kit is Ecofriendly and Highefficient. This total HVAC solution is available to Airconditioning, floor heating, radiators and sanitary hot water supply. All these functions, utilizing a variety of Multi V outdoor unit, minimize energy costs and CO 2 emissions compared to boiler system. Refrigerant Cooling / Heating Provides sanitary hot water supply and floor heating efficiently through lower energy costs compared to a boiler and contribute to green energy enviornment through reduction of CO 2 emissions. Easy Installation Unnecessary to duct for emitting gas, easy to install as compact and modular structure Boiler system Hydro Kit cooling cooling Sanitary Hot water Floor Heating Supply Floor Heating Supply MULTI V Outdoor Unit Heating by Hot water Oil Tank Boiler Cooling by Cold water Ecofriendly Green Energy Solution Variety of Outdoor Combination * Only for medium temp. Ecofriendly system Green energy solution through reduction of CO 2 emmisions (%) 12 1 6 CO 2 emissions 76% A variety of heat pump includes Aircooled, Watercooled and GeoThermal source and outdoor unit can be combined according to installation condition of building or envirenment temperature. 4 2 3% Conventional System Oil Boiler Gas boiler AirCooled Heat Pump HighEfficiecy Products Provide Highefficiecy, hot water solution by connection of variable VRF. WaterCooled Heat Pump 2.2kW Aircooled COP = 3.1 Hot water supply capability of Aircooled HP 3.1kW Electric Energy 1kW WaterCooled COP = 4.2 3.2kW Hot water supply capability of Geothermal HP 4.2kW

Economics High Temperature of Hydro Kit High economic efficiency through lower energy costs compared to hot water system of boiler High Temperature of Hydro Kit Concept High Economical Efficiency through Energy Saving Possible to install with equivalent level of an initial cost as the boiler system and minimize energy costs by lowpriced operating costs. Dual inverter cascade cycle technical Max 55% capacity improvement bettter than medium temperature of Hydro Kit Max 2% heating operating cost reduction better than medium temperature of Hydro Kit 25, 2, 15, 1, 5, Initial Costs 9% 95% O il B o il e r 25, 2, 15, 1, 5, Annual Operating Cost 171% 229% O il B o il e r 1 st Proposal Multi V Hydro Kit (Air Conditioning + Hot water supply + Floor Heating) 2 nd Proposal Multi V Airconditioning + Gas Boiler (Hot water supply + Floor Heating) 3 rd Proposal Multi V Airconditioning + Oil Boiler (Hot water supply + Floor Heating) High volume of Domestic hot water Compared to lower temperature, storing high temperature water in a sanitary tank increases a lot the quantity of mixed water available for the user. Cascade to R134a inverter compressor technology 5, 4, 3, 2, 1, LCC 1 2 3 4 5 6 7 8 9 1 (Year) *Condition of analysis : Except for common items includes Sanitary tank, floor heating coil expense *Economic efficiecy is changeable according to design concept, detailed specificaiton of system O i l B o i l e r Analysis Conditions Building Type : Dormitory, flats Cooling / Floor Heating / Sanitary Hot water for 1 years Cooling : Multi V Indoor unit Floor Heating : Hydro kit (1ea) Sanitary Hot water : Hydro kit (2ea), sanitary Hot water tanks Electricity cost : Average cost in EU Gas cost : Average cost in EU Oil cost : Average cost in EU High Temperature of Hydro Kit Cycle Diagram AIR Leaving water temperature up to 8ºC Outdoor Unit High Temperature Hydro Kit Heating by AirRefrigerant Refrigerant Refrigerant Refrigerant Water Energy Saving through Heat Recovery 5ºC 8ºC Energy costs can be saved by using wasted heat source from indoor to outdoor at cooling. High Temperature Technical Pressure Water Refrigerant Cooling Two Stage HR Unit Heat Absorption R134A Single Stage AIR Enthalpy Heat Emission Indoor Cooling Sanitary Tank

Application Quality Control & Specification Various Application Applicable to a variety of facilities includes hospitals, residences and resorts that need water heating and Domestic hot water supply. LG provides a perfect management from design to service & maintenance. Quality Control Design Installation Commissioning Office University / School Hospital / Clinic Design Specification Support *Air conditioning *Ventilation *Controller Training *LG provide training for installers *Systemized trainning regarding theory and practice SVC&유지보수 SVC & Maintenance Start Run Commissioning Support *Design *Installation Shopping Mall / Restaurant Hotel / Resort Factory Facilities Service Training *SVC/ maintenance Check Installation Conditions and Products Check Operating Conditions and Capability *LGMV Program Hotel Constant cooling & heating are possible at the same time during summer time provide hot water for bathroom using waste heat energy from indoor cooling by indoor unit. Specification Type Hydro Kit () Hydro Kit () Model ARNH1GK2A2 ARNH8GK3A2 Office In the office while cooling HR unit makes sanitary tank to be warmed using waste energy, hot water can be supplied at all times. Power Supply Ø / V / Hz Capacity (Rated) Cooling kw Capacity (Rated) Heating kw Input (Rated) Cooling kw heating kw Casing Dimensions Body w x H x D mm inch Net Weight Body kg (lbs) Heat Exchanger Refrigerant to Water Type R rated Water Flow L/min H head Loss kpa R refrigerant to Refrigerant Type Compressor Type Piping Connections Water Side inlet inch O outlet inch R refrigerant Side Liquid mm(inch) G gas mm(inch) Drain Piping Connection inch Sound Press Level Cooling db(a) H heating db(a) Power Supply Cable N no. x mm 2 Communication cable no. x mm 2 Refrigerant Refrigerant to Refrigerant Refrigerant name Control R refrigerant to Water Refrigerant name Precharged Amount kg (lbs) Control 1 / 2224 / 5 29. 32..1.1 Painted Steel Plate 52 x 631 x 33 215/32 x 2427/32 x 13 35. (77.2) 46. 25. Ø 9.52(3/8) Ø 22.2(7/8) 26 26 3C x CV2.5 2C x CVVSB 1.~1.5 EEV 1 / 2224 / 5 25. 5. Painted Steel Plate 52 x 1,8 x 33 215/32 x 4217/32 x 13 94. (27.2) 36. 2. Twin Rotary Inverter Ø 9.52(3/8) Ø 19.5(3/4) 43 3C x CV4. 2C x CVVSB 1.~1.5 Electronic Expansion Valve R134a 3. (6.6) EEV *Notes Capacities are based on the following conditions: 1. Cooling Temperature : Indoor 27 C(8.6 F) DB / 19 C(66.2 F) WB, Outdoor 35 C(95 F) DB / 24 C(75.2 F) WB, Water Inlet 23 C(73.4 F) / Outlet 18 C(64.4 F) 2. Heating Temperature : Indoor 2 C(68 F) DB / 15 C(59 F) WB, Outdoor 7 C(44.6 F) DB / 6 C(42.8 F) WB, * Water Inlet 3 C(86 F) / Outlet 35 C(95 F), ** Water Inlet 55 C(131 F) / Outlet 65 C(149 F) 3. Piping Length : Interconnected Pipe Length = 7.5m 4. Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero. * **