How Spread Spectrum Clock Generators Accelerate FCC Certification of System Designs



Similar documents
Reducing EMI and Improving Signal Integrity Using Spread Spectrum Clocking

Electromagnetic. Reducing EMI and Improving Signal Integrity Using Spread Spectrum Clocking EMI CONTROL. The authors describe the

Application Note: Spread Spectrum Oscillators Reduce EMI for High Speed Digital Systems

Title: Low EMI Spread Spectrum Clock Oscillators

AND9015. A Solution for Peak EMI Reduction with Spread Spectrum Clock Generators APPLICATION NOTE. Prepared by: Apps Team, BIDC ON Semiconductor

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

EMC Standards: Standards of good EMC engineering

LVDS Technology Solves Typical EMI Problems Associated with Cell Phone Cameras and Displays

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

AVX EMI SOLUTIONS Ron Demcko, Fellow of AVX Corporation Chris Mello, Principal Engineer, AVX Corporation Brian Ward, Business Manager, AVX Corporation

Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications. Application Note. June 2011

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

Design and Certification of ASH Radio Systems for Japan

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

DT3: RF On/Off Remote Control Technology. Rodney Singleton Joe Larsen Luis Garcia Rafael Ocampo Mike Moulton Eric Hatch

CONDUCTED EMISSION MEASUREMENT OF A CELL PHONE PROCESSOR MODULE

Electromagnetic Compatibility Considerations for Switching Power Supplies

W a d i a D i g i t a l

Electromagnetic Compatibility and International Regulatory Approvals

Timing Errors and Jitter

RF Network Analyzer Basics

30 In Compliance October

Low-cost EMI Pre-compliance Testing Using a Spectrum Analyzer

How to Improve Tablet PCs and Other Portable Devices with MEMS Timing Technology

Application Note AN-00126

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

An extended EMC study of an electrical powertrain for transportation systems

Module 11: Conducted Emissions

Design Note DN004. Folded Dipole Antenna for CC25xx By Audun Andersen. Keywords. 1 Introduction CC2500 CC2550 CC2510 CC2511

EMC-conform development of a Tablet-PC

RX-AM4SF Receiver. Pin-out. Connections

Understanding SMD Power Inductors. Application Note. July 2011

EMI can be a difficult

Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants

Embedded FM/TV Antenna System

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

EMC countermeasures for High-Speed Differential Interfaces

USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Features. Modulation Frequency (khz) VDD. PLL Clock Synthesizer with Spread Spectrum Circuitry GND

Broadband over Power Line (BPL) Test Procedures and Equipment Authorization

Clock Recovery in Serial-Data Systems Ransom Stephens, Ph.D.

AN-837 APPLICATION NOTE

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

ACRS 2.0 User Manual 1

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note

VJ 6040 Mobile Digital TV UHF Antenna Evaluation Board

Article from Micrel. A new approach to the challenge of powering cellular M2M modems By Anthony Pele Senior Field Applications Engineer, Micrel

REMOTE KEYLESS ENTRY SYSTEM RECEIVER DESIGN

MAINTENANCE & ADJUSTMENT

Tx/Rx A high-performance FM receiver for audio and digital applicatons

Application Note AN-00125

Data Transmission. Data Communications Model. CSE 3461 / 5461: Computer Networking & Internet Technologies. Presentation B

Regulatory requirements - USA

Why 50% of Products Fail EMC Testing the First Time

Simplifying System Design Using the CS4350 PLL DAC

EMC Countermeasures for In-Vehicle Communication Networks

W O R L D C L A S S H I F I

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

Power Noise Analysis of Large-Scale Printed Circuit Boards

MSAN-001 X-Band Microwave Motion Sensor Module Application Note

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

Grounding Demystified

Germanium Diode AM Radio

POCKET SCOPE 2. The idea 2. Design criteria 3

Miniature Surface-Mount DAA for Audio or Data Transfer XE0402LCC BLOCK DIAGRAM

Quick Start Guide. MRB-KW01 Development Platform Radio Utility Application Demo MODULAR REFERENCE BOARD

Clocking Solutions. Wired Communications / Networking Wireless Communications Industrial Automotive Consumer Computing. ti.

PicoScope 6000A/B Series

Current Probes. User Manual

ILB, ILBB Ferrite Beads

PCXpocket 440. Professional Digital Audio Card. User s manual. DU IS=A

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT

Maximizing Range and Battery Life in Low-Cost Wireless Networks

V CC TOP VIEW. f SSO = 20MHz to 134MHz (DITHERED)

Compliance with TIS and TRP Requirements

Apple iphone/ipod Touch - ieffect Mobile Guitar Effect Accessory & Application

Signal Integrity: Tips and Tricks

Study of RF Spectrum Emissions in High Pressure Sodium and Metal Halide Lamps. Lawrence P. Glaister VE7IT, Automation Engineer.

Application Note AN001

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J test set up, using measured current in NEC and simple TX equations.

How To Counter Noise Noise From A Low Voltage Differential Signaling Circuit

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

APPLICATION NOTE. RF System Architecture Considerations ATAN0014. Description

DSA800 Series Spectrum Analyzer

POWERING IN-FLIGHT ENTERTAINMENT EQUIPMENT FOR COMMERCIAL AIRCRAFT

UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES

Application Note SAW-Components

UNDERSTANDING THE FCC REGULATIONS FOR LOW-POWER, NON-LICENSED TRANSMITTERS

Lecture 1: Communication Circuits

TRIPLE PLL FIELD PROG. SPREAD SPECTRUM CLOCK SYNTHESIZER. Features

Radiated emission measurement of a cell phone processor module using TEM cell

SPREAD SPECTRUM CLOCK GENERATOR. Features

TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS

FM TRANSMITTER & RECEIVER HYBRID MODULES. FM-RTFQ SERIES FM-RRFQ SERIES. Transmitter. Receiver. Applications

Chapter 6 PLL and Clock Generator

Simulation and Design of Printed Circuit Boards Utilizing Novel Embedded Capacitance Material

Transcription:

How Spread Spectrum Clock Generators Accelerate FCC Certification of System s WHITE PAPER

How Spread Spectrum Clock Generators Accelerate FCC Certification of System s Introduction Controlling electro-magnetic emissions is a key consideration of systems design. In today s advanced electronic products, most of the electromagnetic radiated emission originates from the high-speed digital clock signal. As the clock frequency increases, more Electro-Magnetic Interference () is generated. This creates a problem because the Federal Communications Commission (FCC) and other regulatory bodies tightly regulate the maximum amount of that any electronic device may emit. These regulations are designed to make sure that electronic devices will not interfere with each other (e.g., that a person does not lose TV reception when talking on a cell phone). This paper will explain and its effect on FCC certification. Alternative approaches to mitigating will be mentioned, and the benefits of using Spread Spectrum Clock Generators (SSCG) explained. Finally the paper will describe the Fujitsu SSCG family, which is designed to reduce the overall bill of materials (BOM) cost, shorten the design cycle time, and enable firstpass FCC certification success without compromising system performance. and System Concerns To understand why is so important to the FCC, it is helpful to understand the causes of electromagnetic radiation. When electrical current flows in a circuit, an electromagnetic field is created. The strength of this field depends on the frequency and magnitude of the current flow. This field radiates outward from the wires and electronic traces in the equipment. Any radiation that is an unwanted by-product of the electrical circuitry's desired function is called electromagnetic interference or. The sources of electromagnetic emissions can be intentional transmitters, such as cellular phones. However, digital systems such as PCs, PDAs, printers, scanners, and digital cameras also emit unintentional radiation. In digital systems, high-frequency periodic clock signals are the major causes of radiation because they are periodic with the highest frequency, and because the energy is concentrated not only in the peak but also on discrete frequency harmonics. Control and timing signals, address and data buses, interconnect flex cables, and connectors also contribute to emissions. This radiation can degrade the performance of either the equipment that generates it or of other nearby (external) equipment. IEC Traditionally, shielding and filtering are the most common methods used to control, but they are expensive. As frequency increases, the effects of transmission line and ground impedance amplify the radiation and decrease the wavelength, making shielding and filtering less effective. Performing critical signal-integrity and simulations during system development is difficult, time-consuming, and error-prone due to reliance on hard-to-predict models and parameter extractions. This situation worsens with every new product generation due to steadily increasing clock speeds and decreasing supply voltages. FCC Standards CISPR Figure 1 Standards FCC (USA) FN (European Community) DOC (Canada) Radio Law (Japan) Even though it is challenging, mitigating is essential for FCC and other certifications. The FCC regulates all commercial electronic devices (unintentional radio-frequency radiators) sold in the United States if they: employ clocks or oscillators operate at a frequency of greater than 9 KHz use digital techniques. This includes almost every product that contains a microprocessor or microcontroller. If an unintentional radiator is not controlled through proper design techniques (e.g., filtering, shielding or spread spectrum modulation), high levels of energy can be radiated or conducted from the equipment, causing unwanted effects on another device. Determining whether one device will impact the functionality of another is not an exact science, and is much too complex to be documented for every combination of products. However, there are standards to help keep consumers from experiencing problems with their digital equipment. These standard values for electromagnetic waves are being strengthened around the world. The International Special Committee for Radio Interference (CISPR) sets standards for radiated and conducted Page 1

How Spread Spectrum Clock Generators Accelerate FCC Certification of System s Applications International Standard Japan U.S.A. Europe In common CISPR61000-6-3 Residential, commercial, and light industrial regions IEC61000-6-4 Manufacturing areas EN50081-1 Residential, commercial, and light industrial regions EN50081-2 Manufacturing areas Computers and peripherals (ITE), printers, PCs, word processors, displays, etc. CISPR22 Voluntary Control Council for Information Technology Equipment (VCCI) Electrical Appliances and FCC Part 15 Subpart B EN55022 Chemical and medical equipment (ISM), radiofrequency equipment CISPR11 Electrical Appliances and FCC Part 18 EN55011 Ignition equipment for cars, motorboats, etc. CISPR12 Japanese Automotive Standards Organization (JASO) FCC Part 15 Subpart B Directive of End of Life Vehicle (ELV) TVs, radio, audio, etc. CISPR13 Electrical Appliances and FCC Part 15 Subpart B EN55013 Household appliances, portable electric tools CISPR14 Electrical Appliances and EN55014 Fluorescent lamps, lighting control systems CISPR15 Electrical Appliances and FCC Part 18 EN55015 Table 1 List of International Standards electromagnetic interference in each country as shown in Figure 1 on the previous page. (CISPR is a special committee of the International Electro-technical Commission or IEC.) As indicated in Table 1, Europe, Japan, Asia, and the U.S. all have different limits. In order to sell an electronic product worldwide, it must satisfy regulatory requirements in each country. Anything that reduces the peak energy will help a product meet the requirements. To sell an electronic product within the United States, the FCC requires the product have its electromagnetic emissions measured in a specified environment called an range. The device must have electromagnetic emissions in specified frequency bands well below certain specified values. The FCC and other regulatory bodies are concerned with peak (not average) emissions. The FCC regulates the amount of radiated energy in terms of voltage, distance and frequency. In the United States, the FCC has two classes of radiation levels: Class A and Class B as shown in Table 2. Class A devices are digital devices intended for use in commercial, industrial or business environments and not intended for use by the general public or in the home. Class B digital devices are intended to be used in the home but could also be used elsewhere. In general, Class B levels are more difficult to meet than Class A. Table 2 lists the voltage levels allowed under FCC Rules and Regulations (Part 15) for both Class A at 10 meters and Class B at 3 meters. If the EUT (Equipment Under Test) exceeds these limits, the excess energy must be reduced to within the agency limits as shown in Table 2. Reducing the excess amount of to just under the agency limits is dangerous because differences in manufacturing and environmental changes might cause the energy to increase slightly. Most companies require a safety margin to ensure that the device always complies with Frequency Class A (10 meters) Class B (3 meters) (MHz) uv/m db(uv/m) uv/m db(uv/m) 30-88 90 39 100 40.0 88-216 150 43.5 150 43.5 216-960 210 46.5 200 46.0 Above 960 300 49.5 500 54.0 Table 2 FCC Class A and Class B Limits Page 2

How Spread Spectrum Clock Generators Accelerate FCC Certification of System s agency limits even when manufacturing processes or environmental conditions change. Reducing a particular offending frequency that is over the limit at the fifth harmonic can be difficult. The problem is further complicated when a company imposes a 4dB safety margin. The products qualified by FCC will have the following logo on them. After such qualification is granted, the product can be sold anywhere in the U.S. If a company fails to meet the regulatory requirements, it might have to delay shipping or even cancel a product if it can't pass FCC certification in time to capture the market window. Reasons Electronics Products Fail FCC Testing The 10 most common reasons products do not pass FCC requirements at first-pass testing are: 1. Ignoring or downplaying FCC requirements during the initial design phase 2. Selecting the fastest components and highest clock rate 3. Using a single or two-layer board instead of a multi-layer PC board 4. Not considering emissions in the clock layout 5. Not using enough bypass capacitors 6. Using unshielded cables 7. Using plastic connectors 8. Not using ferrites in cable design 9. Not incorporating power line filters 10. Not shielding the chassis properly Figure 2 Test Facility Costs of Testing FCC testing is costly in terms of infrastructure, time and resources. Measuring requires a large infrastructure and a facility. The test facility can be a small room with several antennas that measure the magnetic waves being emitted (called a closed site) or a large outdoor area taking up many acres (called an open site). A closed site is shown in Figure 2. Such test facilities, equipment and methods must be pre-approved (certified) by the government in order for the results to qualify for legal certification of compliance. Measuring requires a different approach than other types of general RF tests, and developing comprehensive emission test steps is often timeconsuming and expensive. In testing, engineers never quite know what signals might be present. Since each new EUT is different, having the correct tools for characterization of the signals is of key importance. Also, knowing the strengths and weaknesses of the tools being used is vital. Highly trained engineers are needed to perform such testing, increasing costs. Electromagnetic Waves Source Interference Current Interference Power Interference Voltage Loop Antenna Wideband Antenna EUT LISN Current Clamp Absorption Clamp Test Receiver or Spectrum Analyzer Figure 3 Example of Measurement Test Set-up Page 3

How Spread Spectrum Clock Generators Accelerate FCC Certification of System s To measure the emission from EUT, the emission must be received via a loop antenna, wideband antenna and a spectrum analyzer or test receiver for measurements as shown in Figure 3 on the previous page. The paperwork is also daunting. The FCC compliance process requires the following documents and reports: Comprehensive Test Plan (details the process and methods employed to test the product) Testing for FCC Part 15 Class A or B Detailed Test Report with descriptions and standards applied Technical File (a collection of technical documents) FCC Declaration of Conformity (the official FCC document that states that the product was tested in conformance with the standards, and that it passed) If regulatory requirements are not met the first time, the engineers need to adapt the shielding techniques. This involves revising the system design and hardware, and repeating all the steps for FCC re-testing. Figure 4 illustrates such repetitive design changes, a requalification that includes PCB layout changes, implementation of filters (which adds to the BOM cost), and the use of an expensive facility again to meet the regulatory requirements. Ways to Reduce Taking into account in the beginning, before testing, clearly saves both time and money. Fortunately, there are existing mechanical and electrical solutions to avoid excessive in any system design. Two common approaches to dealing with are filtering and shielding. Both have definite drawbacks in terms of cost, time and resources. For example, filtering typically uses about $.25 worth of resistors, inductors, and capacitors, and often $.70 worth of common mode chokes and toroids. In many cases, filtering is not enough to allow a system to pass tests, in which case costly shielding may be required. Shielding can easily add several dollars to the cost of a system. Spread Spectrum for Suppression Another method to address signals that emit excessive radiation is clock modulation, also known as spread spectrum. Clock modulation began to appear in computer system designs as early as 1990. Spread spectrum clocking is now popular in portable electronic devices (such as portable navigation and handheld gaming) because of faster clock speeds and the increasing integration of high-resolution LCD displays in smaller and smaller devices. As these devices are designed to be lightweight and inexpensive, passive reduction measures such as capacitors or shielding are not viable options. The spread spectrum method spreads out the energy using frequency modulation instead of concentrating the reference energy on a single frequency. Unlike filtering and shielding, which suppress after it has been generated, SSCG can suppress at the system clock source itself. Using this method, the system can be reduced as much as 20dB. The reduction is greatest at the higher harmonic frequencies. SSCGs are especially effective for reducing common mode noise, one of the most difficult areas to control. SSCG clock modulation works by spreading the emissions over a wider frequency band. This band can be broadened, with subsequent reductions in the measured radiation levels, by frequency modulating the MCU or processor clock over a few hundred KHz. Hence it becomes important to understand the factors that determine the optimal profile for a specific system design, accelerating the design process. Figure 5 on the following page shows that the rate of change in frequency is faster at the minimum and maximum peak frequencies and changes more slowly at the center of the frequency spectrum due to the profile. Schematic Layout PCB Pattern Test Schematic Re- Layout PCB Pattern Repeated Tests Mass Production Figure 4 A Conventional Multi-step System Flow for Reducing Page 4

How Spread Spectrum Clock Generators Accelerate FCC Certification of System s dbµ V/m (as measured by the Quasi-Peak detector in a BMC receiver or spectrum analyzer) 50 The 3rd harmonic emissions from a 60MHz fixed-frequency microcontroller clock 40 The EN 55022 Class A limit 30 20 120 khz 1.92 MHz 120 khz 1.92 MHz The measurement of the same harmonic using a spread-spectrum 60MHz clock with a +0.5% spread selected (spreads of up to +4% are possible) 10 0 178.5 179 179.5 180 180.5 181 181.5 MHz Figure 5 Rate of Change in Frequency As indicated in Table 2, the Class B requirement states that the 60MHz clock (as shown in Figure 5) needs to be within 40dBuV/m. The clock modulation rate in Figure 5 is 120KHz. This low frequency modulation rate is important for several reasons. If the modulation rate is below 120KHz, it is possible to generate audible noise in the system. If the modulation rate is too high (in excess of 200KHz), the effect of modulation might be defeated by the loop bandwidth of the filters used in downstream PLLs. Hence, it is important to have optimum modulation techniques and profiles. In addition to the rate, other important factors to consider when using modulation techniques include: Bandwidth requirements Modulation type: center-spread and down-spread Extent of the harmonic suppression. Using the spread spectrum technique generally has minimal or no impact on other system performance considerations. Slow and controlled modulation does not introduce short-term jitter; Fujitsu s SSCGs typically display the same sub-100ps cycle-to-cycle jitter shown by non-spread-spectrum clocks. The spreading frequency range can be chosen to avoid clock periods shorter than the system minimums. Overall Benefits of Using SSCG The systemic nature of SSCG has major advantages over other -reduction techniques. Specifically, the SSCG method can: Significantly reduce system-radiated Ease FCC certification license approval, speeding up time to market Dramatically simplify and reduce the steps for system design (See Figure 6.) Increase flexibility in programming optimum modulation profiles Reduce infrastructure costs and resources for testing. Schematic Layout PCB Pattern First Pass Test Mass Production Figure 6 SCCG Simplified System Flow Steps Page 5

How Spread Spectrum Clock Generators Accelerate FCC Certification of System s Power (dbm) Power (dbm) decrease effect -21dB @Modulation depth: + 1.5% Frequency (Hz) Modulation Off Energy is distributed by modulating the clock fequency, and thus, the peak is dropped. Frequency (Hz) Modulation On Figure 7 The Fujitsu SSCG The Fujitsu SSCG The Fujitsu SSCG family is designed to shorten the design cycle time, lower the overall BOM cost, and enable first-pass FCC certification success without compromising system performance. Fujitsu s SSCGs take advantage of digital frequency modulation control technology, which uses multi-cycle modulation. As shown in Figure 7, can be decreased by as much as 21dB and can suppress both the fundamental frequency and the harmonics. The effects of the decrease in Figure 7 show the ratio of electric power with decibel mark when the modulation is On/Off. This is represented in the following formula: 10*LOG10 (P1/P2) Where P1/P2 is the electric field strength at modulation functions On or Off: 1. decrease effect = 0dB when modulation is off 2. decrease effect = -21.76dB when P1/P2= 1/150 Features and Benefits Fujitsu s SSCG products offer the following important features: Peak reduction on every harmonic, reducing by as much as 20dB Cycle-to-cycle jitter less than 100ps, which is very low compared to competitive products I/O driving and controlled slew rate abilities Digital frequency modulation control technology and multi-cycle modulation Programmable spread spectrum modulation percentage and profile for optimizing reduction Register programmable, multi-clock (up to 8 clock outputs) and FRAM memory embedded products for design flexibility On/off feature, which provides usage on an asneeded basis Frequency select feature, which allows users to select among multiple frequencies on the same output pin Different output voltage options supported by a single device: 3.3, 3.0, 2.5 and 1.8V Variety of industry standards and compact packages for design flexibility Page 6

How Spread Spectrum Clock Generators Accelerate FCC Certification of System s Mobile System Application Example The following example illustrates the impact of these features on an application. This shows how the Fujitsu SSCG could be used in a mobile phone with no performance degradation. In this example, as illustrated in Figures 8 and 9, multiple clocks are used for the main CPU, GPS and RF blocks. The main sources of in a cell phone are between the controller, digital signal processor (DSP) and memory; and on the flex cable that connects to the display. Figures 10 and 11 show that emission suppression at the main CPU and at the flex cable area is within the FCC regulation limits, respectively. Adding SSCG to the mobile system design dramatically reduced the and brought the fundamental frequency and its harmonics to within the FCC Class 15 levels (listed in Table 2 and shown as waveforms in Figures 10 and 11). Without SSCG With SSCG Sensor Sensor Memory DSP affects communication quality Less Memory DSP Memory SSCG improves communication quality clock data by noise suppression clock data Controller Buffer RF SSCG is the only way to reduce generated on flex cables Controller SSCG RF CMOS Sensor Reference Clock from RF Main System LSI I 2 C I/F for register setting SS Clock DSP Fujitsu SSCG SS Clock PLL Clock Ref Clock LCDC USB Audio Figure 8 Mobile Phone SSCG Application Example Figure 9 Block Diagram Showing Multiple Clocks Magnetic-Field Emission db µ V 90 80-15.9dB 70 60-3.9dB -7.9dB -5.8dB 50 Overlay Plots SS off SS + 1.0% 40 30 20 470 670 870 1070 1270 1470 1670 1870 2070 2270 2470 2670 2870 MHz UHF (ATSC M/H) GSM/UTMS (850/900MHz) GPS GSM/UTMS (1800/1900/2100MHz) Figure 10 Emission Suppression at Main CPU Within FCC Regulation Limits Magnetic-Field Emission Overlay Plots db µ V SS off SS + 1.0% 90 80 70-8.8dB 60-8.3dB 50-5.3dB 40 30 20 470 670 870 1070 1270 1470 1670 1870 2070 2270 2470 2670 2870 MHz UHF (ATSC M/H) GSM/UTMS (850/900MHz) GPS GSM/UTMS (1800/1900/2100MHz) Figure 11 Emission Suppression at Flex Cable Area Within FCC Regulation Limits Page 7

Conclusion Overall, the systemic nature of the spread spectrum method has major advantages over other reduction techniques, helping to dramatically reduce throughout the system. The method has enabled system performance to increase without compromising. Using Spread Spectrum Clock Generators reduces packaging, filtering, shielding, and design-cycle costs. Perhaps more importantly, using SSCGs expedites time-to-market for products that otherwise might fail certification testing. Fujitsu s multi-clock output, programmable, low cycle-to-cycle jitter products provide an economical solution to mitigate expensive problems. For More Information For more information on Fujitsu Spread Spectrum Clock Generators visit http://us.fujitsu.com/micro/sscg or address e-mail to inquiry@fma.fujitsu.com. FUJITSU MICROELECTRONICS AMERICA, INC. Corporate Headquarters 1250 East Arques Avenue, M/S 333, Sunnyvale, California 94085-5401 Tel: (800) 866-8608 Fax: (408) 737-5999 E-mail: inquiry@fma.fujitsu.com Web Site: http://us.fujitsu.com/micro 8 2009 All rights reserved. All company and product names are trademarks or registered trademarks of their respective owners. Printed in U.S.A. EPS-WP-21353-11/2009.