Study of the Natural Circulation Phenomenon for Nuclear Reactors



Similar documents
A RELAP5 STUDY TO IDENTIFY FLOW REGIME IN NATURAL CIRCULATION PHENOMENON

Test Section for Experimental Simulation of Loss of Coolant Accident in an Instrumented Fuel Assembly Irradiated in the IEA-R1 Reactor

A MTR FUEL ELEMENT FLOW DISTRIBUTION MEASUREMENT PRELIMINARY RESULTS

DOSIMETRIC CHARACTERIZATION OF DYED PMMA SOLID DOSIMETERS FOR GAMMA RADIATION

STUDIES FOR A MULTIPURPOSE RESEARCH REACTOR FOR THE CRCN/CNEN-PE

SOLVING REACTOR WATER CLEAN-UP SYSTEM ANOMALIES USING RELAP5 MOD3.3

NUCLEAR ENERGY RESEARCH INITIATIVE

DEVELOPMENT OF A QUALITY MANAGEMENT SYSTEM FOR BRAZILIAN NUCLEAR INSTALLATIONS

IMPLEMENTATION OF A MANAGEMENT SYSTEM FOR OPERATING ORGANIZATIONS OF RESEARCH REACTORS

L.S. de Carvalho, J. M de Oliveira Neto 1. INTRODUCTION IAEA-CN-164-5P01

16. Heat Pipes in Electronics Cooling (2)

C. starting positive displacement pumps with the discharge valve closed.

Experimental Study of Free Convection Heat Transfer From Array Of Vertical Tubes At Different Inclinations

NUCLEAR ENERGY EDUCATION SCENARIO AROUND THE WORLD

Portuguese Health Physics Society: Calibrating Pen Dosimeters with and without a Phantom

Flow Regime Recognition in Two-Phase Thermosyphon Loops Using Pressure Pulse Analyses

CFD SIMULATION OF IPR-R1 TRIGA SUBCHANNELS FLUID FLOW

PROCESSING OF AISI M2 HSS WITH ADDITION OF NbC BY MECHANICAL ALLOYING USING TWO DIFFERENT TYPES OF ATTRITOR MILLS

HEAT TRANSFER ENHANCEMENT ON DOUBLE PIPE HEAT EXCHANGER BY WIRE COILED AND TAPER WIRE COILED TURBULATOR INSERTS

Numerical Simulation of Thermal Stratification in Cold Legs by Using OpenFOAM

Performance Test of Solar Assisted Solid Desiccant Dryer

José Egidio M.Tondin 1, Mario O. de Menezes 1, Marina B.A.Vasconcellos 1 and João A.Osso Jr. 1 ABSTRACT 1. INTRODUCTION

18th International Congress of Mechanical Engineering

DEVELOPMENT AND IMPLEMENTATION OF AN AUTOMATED SYSTEM TO EXCHANGE ATTENUATORS OF THE OB85/1 GAMMA IRRADIATOR

Testing methods applicable to refrigeration components and systems

ACOUSTIC CAVITIES DESIGN PROCEDURES

UNIVERSITÀ DI PISA DIPARTIMENTO DI INGEGNERIA MECCANICA, NUCLEARE E DELLA PRODUZIONE VIA DIOTISALVI 2, PISA

Accidents of loss of flow for the ETTR-2 reactor: deterministic analysis

VIRTUAL INSTRUMENTATION ON MOBILE DEVICES FOR DEPLOYMENT IN NUCLEAR INSTALLATIONS

Solar Hot Water Heaters

5.2. Vaporizers - Types and Usage

Verification and Validation of a Single-Phase Natural Circulation Loop Model in RELAP5-3D. Nicolas Zweibaum, Raluca O. Scarlat and Per F.

International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No , March-April 2015

EFFECT OF MICROSTRUCTURE ON PROPERTIES AND PERFORMANCE OF SPRAY FORMED AISI M2 HIGH-SPEED STEEL

Determination of the Effective Energy in X-rays Standard Beams, Mammography Level

Research Topics in Renewable Energies in Brazil

How does solar air conditioning work?

Zhao et al. 2.2 Experimental Results in Winter Season The analysis given below was based on the data collected from Nov to Mar. 15, 2004.

IMPROVEMENT OF GAMMA CALIBRATION PROCEDURES WITH COMMERCIAL MANAGEMENT SOFTWARE

Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchanger

15th Discussion Meeting on Thermodynamics of Alloys

EVALUATION OF A ENERGY CONSUMPTION INDEX FOR COMMERCIAL BUILDINGS IN BRAZIL

ENERGY EFFICIENCY IN PRODUCTION ENGINEERING COURSES

1 DESCRIPTION OF THE APPLIANCE

Modelling and Simulation of the Freezing Systems and Heat Pumps Using Unisim Design

How To Test Water Penetration On Concrete Block And Mortar

UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE CONVECTIVE HEAT TRANSFER

HEAVY DUTY STORAGE GAS

جامعة البلقاء التطبيقية

CFD simulation of fibre material transport in a PWR core under loss of coolant conditions

How To Know If A Refrigeration System Is Efficient

DESIGN OF AIR CONDITIONING SYSTEM IN AUTOMOBILE

Split Controller. User Manual SM-SS-F 2009/01/04

CFD Topics at the US Nuclear Regulatory Commission. Christopher Boyd, Ghani Zigh Office of Nuclear Regulatory Research June 2008

VDL Klima. Marine cooling solutions. Strength through cooperation

REGISTRATION EXAMINATION, JUNE 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

FEDSM Flow Boiling Heat Transfer Enhancement in Subcooled and Saturated Refrigerants in Minichannel Heat Sinks

COMPARATION BETWEEN PIII SUPERFICIAL TREATMENT AND CERAMIC COATING IN CREEP TEST OF Ti-6Al-4V ALLOY

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

VCR Ion Beam Sputter Coater

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Natural Convection. Buoyancy force

SCDAP/RELAP5-3D : A State-of-the-Art Tool for Severe Accident Analyses

Investigations of a Long-Distance 1000 MW Heat Transport System with APROS Simulation Software

PERFORMANCE EVALUATION OF THE REFERENCE SYSTEM FOR CALIBRATION OF IPEN ACTIVIMETERS

Thermo Siphon Solar Systems

Ravi Kumar Singh*, K. B. Sahu**, Thakur Debasis Mishra***

Operational Reactor Safety /22.903

Natural geothermal energy.

Keywords: Fuzzy Logic, Control, Refrigeration Systems and Electronic Expansion Valves.

Daikin Altherma hybrid heat pump. The natural combination

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

FLASH TANK ECONOMIZER PRODUCT GUIDE

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Energy Recovery Systems for the Efficient Cooling of Data Centers using Absorption Chillers and Renewable Energy Resources

DESIGN, FABRICATION AND ELETRICAL CHARACTERIZATION OF SOI FINFET TRANSISTORS

THE EFFECT OF THE HDDR PROCESS ON THE PRODUCTION OF Pr-Fe-Co-B-Nb SINTERED MAGNETS

Enhancing Process Control Education with the Control Station Training Simulator

GEOTHERMAL HEATING AND COOLING INTRODUCTION

How Ground/Water Source Heat Pumps Work

REMOTE CONTROL OF REAL EXPERIMENTS VIA INTERNET

Two-Phase Evaporative Precision Cooling Systems

Waste Heat Recovery through Air Conditioning System

Link-Up. Solid Fuel Association Guide to Central Heating.

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

International journal of Engineering Research-Online A Peer Reviewed International Journal Articles available online

Lake at IPEN location

Simulation of Water-in-Oil Emulsion Flow with OpenFOAM using Validated Coalescence and Breakage Models

Hybrid Modeling and Control of a Power Plant using State Flow Technique with Application

Transcription:

Study of the Natural Circulation Phenomenon for Nuclear Reactors Thadeu das Neves Conti, Gaianê Sabundjian, Walmir M. Torres, Luiz A. Macedo, Delvonei A. Andrade, Pedro E. Umbehaun and Roberto N. Mesquita Instituto de Pesquisas Energéticas e Nucleares (IPEN / CNEN - SP) Av. Professor Lineu Prestes 2242 05508-000 São Paulo, SP, Brasil Abstract. The objective of this paper is to study the natural circulation phenomenon in one and two-phase regime. There has been a crescent interest in the scientific community in the study of the natural circulation. New generation of compact nuclear reactors uses the natural circulation for residual heat removal in case of accident or shutdown. For this study, the modeling and the simulation of the experimental circuit is performed with the RELAP5 code. The theoretical results showed to be satisfactory when compared with the experimental ones. Keywords: Natural Circulation, RELAP5, Two- Phase Flow. PACS: 28 INTRODUCTION Natural circulation phenomenon is very important for the safety and design of nuclear reactors. Advanced reactors have been designed using passive safety systems based on natural circulation [1]. There are also some conceptual designs using the natural circulation where the components and systems have been simplified by eliminating pumped recirculation systems and pumped emergency core cooling systems [2]. A theoretical and experimental program is under development at IPEN-CNEN/SP. The objective is to understand the complex phenomena involving the instabilities in one and two-phase flow in a natural circulation circuit. This study started at the Departamento de Engenharia Química da Escola Politécnica da USP. Experiments concerning one and two-phase flow in natural circulation regime were performed. Several articles were published [3, 4, 5 and 6]. Other experiments were carried out by different authors as found in the literature [7, 8 and 9]. However this circuit needed a reformulation since it was constantly presenting some troubles with the instrumentation. A remodeling program was suggested together with a proposal to move it from Escola Politécnica of USP to IPEN-CNEN/SP. After XXXIII Brazilian Workshop on Nuclear Physics AIP Conf. Proc. 1351, 391-396 (2011); doi: 10.1063/1.3608994 2011 American Institute of Physics 978-0-7354-0908-8/$30.00 391

some modifications it became operational at IPEN-CNEN/SP. A new interface using Labview pack [10] was developed for the new data acquisition system. Experiments were performed for one and two-phase flow. RELAP5 code [11] was used to simulate this circuit. In order to validate RELAP5 models, the results compared to the experimental ones. OBJECTIVE The goal of this work is to describe the circuit modernization process and present a comparison between numerical simulation and experimental results for one and twophase flow in natural circulation regime. EXPERIMENTAL CIRCUIT DESCRIPTION The experimental circuit consists of a rectangular glass loop with an electrical heat source and a coil cooler. Glass is used in the circuit to allow the flow visualization as to identify the flow patterns. The main dimensions of the circuit as well as the thermocouple positions are indicated in Fig. 1 and Fig. 2. FIGURE 1. Loop diagram 392

The heated section is a 75 mm cylindrical glass tube with two electrical heaters. The power applied is controlled in the range of 0 to 8600 W. The cooler is all made from glass with 33 mm internal diameter, 610 mm high and 2 parallel coils. The coolant is tap water at ambient temperature. An expansion tank, acting as a PWR pressurizer, is partially filled with water and opened to the ambient at the top end. At the bottom end it is connected to the loop in order to deal with the water specific volume changes. To prevent vapor admission to the expansion tank during two-phase flow experiments, the surge line is connected to the horizontal section of the cold leg. To simulate the thermal hydraulic behavior of the circuit a first model [12] was developed to RELAP5 code. PIPE and BRANCH components represent all the facility. At the beginning, all the volumes were filled with water except that one representing the upper part of expansion tank, which has also some air. Heat losses to the environment were also considered. This model was able to predict the behavior of the one and two-phase experiments. FIGURE 2. Natural Circulation Circuit photo 393

Experiments showed that the two-phase oscillation only started when the upper part of the hot leg became completely full of vapor. The saturation temperature is considered as the temperature to the change from liquid to vapor phase, in the pressure of the circuit, disregarding the presence of non-condensable gases. Table 1 presents operational conditions for the one and two-phase flow. TABLE 1. Operational condition of the experiment One-phase flow Operational conditions Power: 1000 W Cooling Water: 0.0278 kg/s Initial Temperature: 22.4 0 C Environment Temperature: 21 0 C Two-phase flow Operational conditions Power: 7500 W Cooling Water: 0.0278 kg/s Initial Temperature: 23.3 0 C Environment Temperature: 18 0 C RESULTS For low power levels, there is no phase change and, after a damped oscillatory initial behavior, a stationary flow regime is established. For higher power levels the two-phase flow patterns are observed at the beginning, followed by a two-phase oscillatory regime. Fig. 3 and Fig. 4 show the comparison of measured and calculated temperature for one point of the circuit to one and two-phase flow, respectively. This point corresponds to T12 thermocouple represented in Fig.1. RELAP5 was able to represent the natural circulation behavior in two-phase flow, capturing its oscillations, Fig. 4. 80,0 70,0 60,0 Temperature (C) 50,0 40,0 30,0 20,0 T12 - EXP T12 - RELAP5 10,0 0,0 0 500 1000 1500 2000 2500 3000 3500 Time (s) FIGURE 3. Temperature theoretical/experimental (T12) in one-phase flow 394

120,00 100,00 Temperature (C) 80,00 60,00 40,00 T12 - RELAP5 T12 - EXP 20,00 0,00 0 500 1000 1500 2000 2500 3000 3500 Time (s) FIGURE 4. Temperature theoretical/experimental (T12) in two-phase flow CONCLUSION Experiments were performed in one and two-phase flow. It was also numerically simulated with RELAP5. Theoretical and experimental results showed good agreement. ACKNOWLEDGEMENTS The authors wish to acknowledge the support for this work by the University of São Paulo. REFERENCES 1. M.E. Braaten and W. Shyy, Study of Pressure Correction Methods with Multigrid for Viscous Flow Calculations in Nonorthogonal Curvilinear Coordinates, Numer. Heat Transfer 11, 1987, pp. 417-442. 2. Y. Jaluria and K.E. Torrance, Computational Heat Transfer, Hemisphere, Washington, D.C., 1986. 3. Tema Especial de Termoidráulica do XI Encontro Nacional de Física de Reatores, Poços de Caldas MG, Brasil, 1997, pp. 1-31. 4. G. Sabundjian, D. A. de Andrade, P. E. Umbehaun, W. M. Torres, A. Belchior Jr., A. J. A. de Castro, R. T. V. da Rocha, O. L. A. Damy, Simulação e Análise do Fenômeno de Circulação Natural Monofásica e Bifásica no Circuito Experimental Instalado na Engenharia Química POLI USP, com o Código RELAP5, International Nuclear Atlantic Conference, Santos, SP, Brasil, 2005, pp. 1-7. 5. G. Sabundjian, D. A. de Andrade, P. E. Umbehaun, W. M. Torres, A. Belchior Jr., A. J. A. de Castro, R. T. V. da Rocha, O. L. A. Damy, E. Torres, Análise Experimental do Fenômeno de Circulação Natural, Encontro Nacional de Ciências Térmicas, Curitiba, PR., 2006, pp. 1-7. 6. G. Sabundjian, D. A. de Andrade, P. E. Umbehaun, W. M. Torres, A. J. A. de Castro, T. N. Conti, P. H. F. Masotti, R. N. de Mesquita, P. A. P.aladino, F. A. Braz Filho, E. M. Borges, A. Belchior Jr., R. T. V. da Rocha e O. L. A. Damy, Análise Teórico e Experimental do Fenômeno de Circulação Natural, Encontro Brasileiro sobre Ebulição, Condensação e Escoamento Muiltifásico, Florianópolis, SC, Brasil, 2008, pp. 1-8. 395

7. A. Kaliatka, E. Uspuras, M. Vaisnoras and G. Krivoshein, "Analysis of decay heat removal from RBMK-1500 reactor in decommissioning phases by natural circulation of water and air." Nuclear Engineering and Design 240, 2010, pp. 1242-1250. 8. M. Azzoune, L. Mammou, M. H. Boulheouchat, T. Zidi, M. Y. Mokeddem, S. Belaid, A. Bousbia Salah, B. Meftah and A. Boumedien, "NUR research reactor safety analysis study for long time natural convection (NC) operation mode." Nuclear Engineering and Design 240, 2010, pp. 823-831. 9. H. Omar, N. Ghazi, F. Alhabit and A. Hainoum, "Thermal Hydraulic analysis of Syrian MNSR research reactor using RELAP5/Mod3.2 code." Annals of Nuclear Energy 37, 2010, pp. 572-581. 10. LabView 7.0 Express, National Laboratory, USA, 2003. 11. RELAP5/MOD3.2.2Gamma, NUREG/CR-5535, IDAHO LAB. SCIENTECH Inc., Idaho, 1999. 12. E. M. Borges, F. A. Braz Filho, G. Sabundjian, Familiarização do programa computacional RELAP5. Relatório Técnico da Divisão de Energia Nuclear, IEAv, CTA, São José dos Campos, SP, Brasil, 2006. 396

Copyright of AIP Conference Proceedings is the property of American Institute of Physics and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use.