SH-Sim: A Flexible Simulation Platform for Hybrid Storage Systems
|
|
|
- Neil Stephens
- 10 years ago
- Views:
Transcription
1 , pp SH-Sim: A Flexible Simulation Platform for Hybrid Storage Systems Puyuan Yang 1, Peiquan Jin 1,2 and Lihua Yue 1,2 1 School of Computer Science and Technology, University of Science and Technology of China 2 Key Laboratory of Electromagnetic Space Information, Chinese Academy of Sciences [email protected] Abstract Recently, it has been more and more popular to build hybrid storage systems on the basis of SSD (Solid State Drives) and HDD (Hard Disk Drive). In order to evaluate the performance of various hybrid storage based algorithms, this paper proposes a flexible simulation tool called SH-Sim. SH-Sim aims to provide a flexible virtual hybrid disk which is made up of a virtual SSD and a virtual HDD. SH-Sim can run on the various types of SSDs and HDDs with different parameter configurations. SH-Sim not only simulates the hardware features of HDD and SSD, but also provides a virtual management layer for the algorithms to support the switching between algorithms. The experiment proves SH-Sim can simulate the hardware performance effectively and can support the running of various algorithms. Keywords: Hybrid storage, DiskSim, SSD, Flash memory, HDD 1. Introduction As we know, although SSD has the performance significantly better than HDD, the high price makes it impossible to replace HDD totally. For the tradeoff between performance and price, the hybrid storage based on SSD and HDD has been the research issue. A lot of researchers have proposed a number of hybrid storage managements [1-3], but these works is restricted by 2 problems. Firstly, the experimental environment is generally built by attaching SSD and HDD on PC. But it is impossible to test the effect of an algorithm on all devices because there are too many types of SSD and HDD. Especially, the SSD technology of various companies is very different and there is a great gap between the high-end and low-end SSD, which brings much trouble to test the algorithms. Secondly, different researchers generally have various experimental environments with different devices and the hybrid storage research greatly relies on the hardware condition, so it is very hard to make the algorithm comparison which disturbs the algorithm evaluation. Because of the two points as above, a hybrid storage simulation being flexible and recognized becomes the researchers requirement. The ideal simulation should have some features as below. (1) The simulator not only simulates flash and hard disk, but also supports to simulate the hardware of the storage subsystem, like bus, I/O scheduling and so on. (2) The tool calculates the latency according to the work mode of device other than the static parameter. ISSN: IJGDC Copyright c 2014 SERSC
2 (3) In order to support the hybrid storage on different types of flash and disk, the tool must be configured flexibly for kinds of flash and disk. (4) The tool should be accepted widely by the researchers, so it is best to take a popular open source object as its base. Based on the open source DiskSim [4], we propose a simulation named SH-Sim for the hybrid storage research. SH-Sim can support SSD and HDD. The contribution of this paper is below. (1) We provide a flexible, accurate simulation SH-Sim. It is not only a tool for the hybrid storage research but also a platform to compare the algorithms. (2) SH-Sim has a virtual flash disk (VFD) layer to support the SSDs having different types of flash chip. Besides, SH-Sim defines a structure and method to simulate the hardware feature of flash structure, flash operations and flash work. (3) SH-Sim also has virtual hybrid storage (VHS) layer to load the hybrid storage algorithms having different architecture. VHS provides a set of interfaces for the hybrid storage management model. The rest of this paper is organized as follow: the chapter 2 discusses the related work, the chapter 3 describes the SH-Sim in details, the chapter 4 shows the experiment on SH-Sim, the chapter 5 is the conclusion of this paper. 2. Related Work There are some disk simulations for HDD or SSD before. The most famous one is DiskSim. DiskSim is an open source project maintained by CMU [4]. It is a simulation for HDD and it is version 4.0. It is very popular among academia and industry. DiskSim has some its own features. First, it not only simulates the I/O latency of HDD, but also simulates the whole circuit of a storage sub system including bus, driver, adapter, etc, which help DiskSim calculate the I/O latency close to real device. Second, DiskSim adopts modular design to build its architecture, which is good for the redevelopment. Third, DiskSim can be configured easily by setting the configuration file for different types of HDD. But DiskSim has some features not suitable to SSD. First, DiskSim has its disk model designed as mechanical structure for HDD, but SSD is an electronic device. So DiskSim cannot support flash disk. Second, because DiskSim is designed for only one media device, its storage management cannot support the devices made by different media. Third is the most important that DiskSim cannot support different types of devices meanwhile due to it has no flexibility for the devices having different storage architectures. DiskSim must be modified for hybrid storage design. Flash-DBSim is another open source object which is a simulation for only flash disk [5, 6]. Flash-DBSim is developed to support not only the algorithms above SSD like B+ tree, but also the technology inside SSD, such as FTL. It realizes FTL and buffer management inside, which can be changed for research. There have been some work running on this simulation [7, 8], but it has some disadvantages. First, Flash-DBSim has no simulation of the whole circuit, such as bus, driver, etc., So Flash-DBSim is not accurate. Second, Flash-DBSim calculates the I/O latency simply with the static parameter of flash chip. It has nothing with the work mode of flash chip, which means inaccurate. Third, Flash-DBSim does not support hybrid storage. As discussed above, the both tools have some limit. We combine the advantages of the two simulations and improve their disadvantages. We use DiskSim to simulate the hardware of the hybrid storage system for the latency of bus, controller, adapter, and so on. Then Flash-DBSim is an example for us to simulate the flash device, but our flash simulation is on DiskSim and its latency is not static parameters. So this paper has a 62 Copyright c 2014 SERSC
3 new flash simulation embedded into DiskSim and proposes a hybrid storage management modular in the controller to build SH-Sim. 3. Design of SH-Sim 3.1. SH-Sim Architecture DiskSim has a complete circuit simulation of a storage subsystem, which can help SH-Sim simulate the latency of every module inside SSD and HDD. Besides, DiskSim has provided a good HDD simulation which is named disk model inside. So there is no need to reinvent the wheel for us. This paper focuses on the flash model and hybrid storage manager. As mentioned before, SH-Sim takes DiskSim as its base, as shown in Figure 1. The white part is from DiskSim and the gray part is our work. The disk model simulates magnetic disk of HDD. The mem model simulates the buffer inside HDD. The controller simulates the kernel of the subsystem and controls all the operation of simulation. The adapter simulates the scheduler on disk. The bus model is the simulation of the bus on the subsystem. SH-Sim adds the hybrid storage management above the controller through VHS and loads a flash model on the bus for the flash disk. Hybrid storage manager uses VHS to connect to DiskSim, which makes sure that the different hybrid storage policies can be realized without considering the compatible problem. The flash device in hybrid storage is simulated by the flash model, which has VFD to support different types of flash. The hard disk is simulated by the disk model of the original DiskSim. Trace Device Driver Hybrid Storage Manager Controller Adapter Bus MEM Model Disk Model Flash Model 3.2. Flash Model Figure 1. SH-Sim Architecture Flash model is made up of 3 parts including access interface, FTL module and flash hardware, as shown in Figure 2. Because SH-Sim is built on DiskSim, the access interface set is designed as the interface of disk model inside DiskSim for compatibility. Bus can access the flash mod-el without any modify. The FTL module is the storage management on flash. It loads the flash translation layer (FTL), garbage collection and wear leveling to simulate the work of SSD. SH-Sim Copyright c 2014 SERSC 63
4 realizes NFTL [9] in the code. The FTL code can be replaced by any other algorithms with the FTL interface. So it supports to test FTL algorithm. Flash hardware is the part to simulate the flash chip. It uses VFD to support various types of flash. VFD is an interface defining the access operations of flash including the page read, page writes, block erase, etc. So the upper module can access the flash simulation by the VFD s interfaces. Because of VFD, the flash hardware can support the simulation for the various types of flash. Access Interface Set FTL Code FTL Interface FTL Module Flash-1 Simulation... Flash-n Simulation VFD Flash Hardware Figure 2. Flash Model Overview The flash simulation is built based on the real flash. The flash has a multi-layer structure. A flash chip is made up of lots of blocks which are an erase unit. A block is made up of 64 or 128 or more pages which is the read/write unit. A page is made up of lots of cell and a page register. The flash simulation is Figure 2 is designed as the block-page structure. Figure 3. Radom Write Operation of K9HBG08U1M The flash I/O latency is decided by its work mode. The flash chips of different types have different work modes. SH-Sim has its flash simulation from a Samsung flash [10] in the code. The work mode of a real flash contains 3 steps: command, address and data. Each flash has a command set including more than 10 basic operations. The flash works as follow steps: first step, flash receives the command to ensure the request, which takes up 2 cycles. Second step, 64 Copyright c 2014 SERSC
5 flash receives the basic address of the data transferred, which takes up 5 cycles. Third step, flash starts transferring the data and the clock cycles of this step is proportional to the requested data size. There are some intervals between the 3 steps. For example, Figure 3 shows the clock cycle of read operation for the flash Samsung K9HBG08U1M [10]. Figure 4. Radom Read Operation of K9HBG08U1M According to Figure 3 and 4, the I/O latency of flash is made up of all the work cycles. t WC is the latency of that one byte is transferred to flash s page register from outside. t PROG is the latency of that one byte is written to the flash cell from page register. t R is the latency of that data transfer from cell to register. Other parameters shown in Figure 3 and 4 can be found in the datasheet [10]. The Figure 3 and 4 proves that the I/O latency is decided by the work mode but static parameter. The I/O latency of read and write is calculated for the flash as formula (1) and (2). t t 7 t t t P a g es ize t (1) read W C R RR RC RHZ t t 6 t t P agesize t t t t t (2) w rite W C A D L W C W C W B P R O G W C W H R The flash simulation can get the latency of other operations by their work wave. Then different flash gets its simulation by redefining the interface of VFD according to their work wave Hybrid Storage Manager DiskSim has its address management on one or more disks, but it cannot decide which disk the data should be on and move the data between the disks. So DiskSim storage manager does not support the hybrid storage. SH-Sim proposes hybrid storage manager for the algorithms, as shown in Figure 5. The main function of hybrid storage manager is to maintain the address mapping information and adjust the page placement by the hybrid policy. VHS contains 2 components which are interface and access monitor. The interface provides the functions to get the address mapping as shown in Table 1. The access monitor maintains a data structure pg_info to record page s access information. Mapping table is a structure to store the map information. It is read by the VHS and update by the page placement. Page placement is forked by the monitor and it decides the page Copyright c 2014 SERSC 65
6 placement with the hybrid policy, so page placement can update the mapping table and execute the migration when a page should be migrated. SH-Sim VHS Interface Access Monitor Mapping Table Logic Address Device Phy Address HDD SSD Hybrid Policy Page Placement Figure 5. Hybrid Storage Manager Overview As shown in Table 1, the function pginitialize is the initialization of hybrid storage manager including building the mapping table, applying VHS and registering the hybrid policy. The important function is Tempchange which is the migration of hybrid storage manager. It is forked by the model page placement and it calls the origin functions of DiskSim to generate write request on the target device. Except that, the functions pgchange_for_physicalread and pgchange_for_physicalwrite are used for the read and write request in hybrid storage manager. As mentioned in Table 1, hybrid type is the flag of hybrid policy. Each function of page placement is a switch-case structure on hybrid type. Every new hybrid policy must be registered a flag and then added into the switch-case structure. Table 1. Main Functions of Interface Function pginitialize(ioreq_event, hybridtype) pgchange_for_physicalread (ioreq_event,hybridalgo) pgchange_for_physicalwrite (ioreq_event,hybridalgo) Tempchange(ioreq_event,tempchan gealgo,origin_pg_type) Description Hybrid stroage manager initialization, hybridtype is the registered flag of different algorithms. Read request for the page hybridalgo, hybridalgo is logical address and it is ruened by the mapping table Write request for the page hybridalgo, hybridalgo is logical address and it is ruened by the mapping table Migration func, it calls the DiskSim origin function to generate write request on target device. Table 2. Main Members of Pg_info Member pid devno blkno pg_pw pg_pr pg_lw pg_lr pg_cost Description The logical address of page The number of disk the page on The number of block the page belonged to The counter of the page physical writing form buffer or disk The counter of the page physical reading from disk or buffer The counter of the page writing hit in buffer The counter of the page reading hit in buffer The access cost of the page claculated by hybrid policy The pg_info in Table 2 is the basic information of each page. It is initialized by the access monitor and it is transferred between VHS, page placement and hybrid policy models. The access history is recorded in this structure. The parameter pg_cost is the access cost calculated by the hybrid policy model according to the access history and it can impact the page placement. The parameter blkno is the mapping address. If the page is on HDD, blkno is its physical address. If the page is on SSD, blkno is another logical address which is mapped to physical address in FTL of flash model. 66 Copyright c 2014 SERSC
7 This paper selects 3 hybrid policies from the paper [11]. They are conservative, optimistic and hybrid. SH-Sim is test separately with the 3 policies in experiment. 4. Experiment The experiment s main target is to test the accuracy and flexibility of SH-Sim. The HDD Simulation of SH-Sim is the disk model in DiskSim and DiskSim has been proved accuracy well, so the experiment focuses on the SSD simulation and hybrid storage. The SSD Simulation test is executed on SH-Sim with disk model unattached, so the SH- Sim is just a SSD simulation. Then we choose 2 real SSD devices, as shown in Table 3. SH- Sim configuration parameters are set according to the datasheet [12] of the flash type inside the devices. Table 3. The SSD Devices Picked for Experiment ID SSD type Flash type SSD-1 OCZ AGT3-25Satellite-60G Micron 29F64G08CBAAA-WP SSD-2 INTEL SSDSA2CT040G3 Micron 29F64G08ACME1 Disk-h ST500LM000 K9LCGY8S1B-HCK0 There are 10 trace files generated by DiskSim as shown in Table 4. The trace files are test on the real devices and SH-Sim separately, and then we can estimates the SSD simulation accuracy by comparing the result, as shown in Fig 6. The real SSD is attached to PC with Linux 3.0 and open with flag O_DIRECT. We generate I/O requests to the device from trace and then record the real run time. SH-Sim takes trace files as input and calculates the I/O latency for every request and then gets the run time for whole trace. The result in Fig 6 tells the SSD simulation is very close to the real device. The accuracy of flash model in SH-Sim gets proved. Table 4. Trace Files for SSD Simulation Test Trace Trace number Read:Write : : : : : : : : : :1 Table 5. Trace Files for Whole SH-Sim Test Trace Trace number Read Proportion % % % % % Copyright c 2014 SERSC 67
8 As shown in Figure 6, no matter the trace is read trend or write trend, the run time calculated by SH-Sim with flash model is very close the real device. This result proves that SH-Sim can simulate the flash device accurately. Considering SH-Sim utilizes DiskSim to simulate HDD, it means SH-Sim can support the hybrid storage simulation. Figure 6. The Real SSD and SH-Sim SSD Simulation The other experiment is to test SH-Sim with 3 hybrid algorithms mentioned before and compare SH-Sim with the real hybrid disk. The selected hybrid disk is ST500LM000 as shown in Table 3. The configuration file of SH-Sim is set according to the datasheet of the flash type inside ST500LM000. The trace files are generated by DiskSim as shown in Table 5. Besides, we choose 2 real devices including SSD-2 and HDD to compare. 68 Copyright c 2014 SERSC
9 Figure 7. Average I/O Latency of Real Devices and SH-Sim The real devices are attached to PC with Linux 3.0 and open with O_DIRECT, The trace files are executed on them and their latency is recorded. The I/O latency of SH- Sim is calculated with 3 hybrid policies. The result is shown in Figure 7. Disk-h has the performance between SSD-2 and HDD. Because Disk-h is a black box to us, so we cannot Figure out the algorithms inside it, which means SH-Sim can-not get the same hybrid policy as Disk-h. The 3 policies of SH-Sim are very different from the algorithms inside Disk-h, so there is a gap between SH-Sim and Disk-h. Besides, the 3 hybrid policies are all proposed based on the access cost calculation, so their test results are very similar. The realization of 3 hybrid policies in SH-Sim shows SH-Sim can support different hybrid storage algorithms and this is a good example to compare different hybrid policies on SH-Sim. The 3 tests prove the flexibility of SH-Sim. The result of SH-Sim is between SSD-2 and HDD, which tells SH-Sim can support the hybrid storage research. The two experiments above prove the accuracy and flexibility of SH-Sim. So SH-Sim can support the hybrid storage research and meet the requests of most researchers. 5. Conclusion and Future Work This paper proposes SH-Sim for hybrid storage research. SH-Sim is a hybrid stor-age simulation built based on DiskSim with new components flash model and hybrid storage manager. It has an accurate hardware simulation including HDD and SSD, which can flexibly support flash of various types. Besides, SH-Sim has a flexible hybrid storage manager which can support different hybrid policies, so SH-Sim is a good tool to test and compare the hybrid storage algorithms for researchers. The future work will focus on two aspects. First, flash model of SH-Sim cannot support the parallelism of flash chips yet, which causes SH-Sim cannot simulate the high-end SSD, so we Copyright c 2014 SERSC 69
10 will expand VFD and simulate SSD-inside control algorithms [13] to support that. Second, The VHS and access monitor must be expanded for more and more requirements of hybrid algorithms. Acknowledgements This work is supported by the National Science Foundation of China under the grant no and no References [1] G. Soundararajan, V. Prabhakaran, M. Balakrishnan and T. Wobber, Extending SSD lifetimes with diskbased write caches, 8th USENIX conference on File and storage technologies, USENIX Association, (2010), pp [2] H. Jo, Y. Kwon, et al., SSD-HDD-hybrid virtual disk in consolidated environments, Euro-Par 2009-Parallel Processing Workshops, Springer, Berlin Heidelberg, vol. 6043, (2010), pp [3] P. Yang, P. Jin and L. Yue, Hybrid storage with disk based write cache, Database Systems for Advanced Applications, Springer Berlin Heidelberg, vol. 6637, (2011), pp [4] Paralell Datalab, School of Computer Science Electrical & Computer Engineering, Carnegie Mellon University, [5] X. Su, P. Jin, X. Xiang, K. Cui and L. Yue, Flash-DBSim: a simulation tool for evaluating flash-based database algorithms, In Computer Science and Information Technology, ICCSIT. 2nd IEEE International Conference on, IEEE, (2009), pp [6] P. Jin, X. Su, Z. Li and L. Yue, A Flexible Simulation Environment for Flash-aware Algorithms, the 18th ACM Conference on Information and Knowledge Management (CIKM'09), ACM press, (2009), [7] Z. Li, P. Jin, X. Su, K. Cui and L. Yue, CCF-LRU: A New Buffer Replacement Algorithm for Flash Memory, IEEE Transaction on Consumer Electronics, vol. 55, no. 3, (2009), pp [8] P. Jin, Y. Ou, T. Haerder and Z. Li, ADLRU: An Efficient Buffer Replacement Algorithm for Flash-based Databases, Data and Knowledge Engineering (DKE), Elsevier, vol. 72, (2012), pp [9] J. Kim, J. Min Kim, S. H. Noh, et al., A space efficient flash translation layer for compact flash systems, IEEE Trans on Consumer Electronics, IEEE, vol. 48, (2002), pp [10] Samsung flash chip K9HBG08U1M datasheet, pdf.html. [11] I. Koltsidas and S. D. Viglas, Flashing up the storage layer, Proceedings of the VLDB Endowment, ACM, vol. 1, no. 1, (2008), pp [12] Micron flash chip 29F64G08CBA, [13] H. Zhao, P Jin, P. Yang and L. Yue, BPCLC: An Efficient Write Buffer Management Scheme for Flash- Based Solid State Disks, International Journal of Digital Contents and its Applications (JDCTA), vol. 4, no. 6, (2010), pp Copyright c 2014 SERSC
Implementation of Buffer Cache Simulator for Hybrid Main Memory and Flash Memory Storages
Implementation of Buffer Cache Simulator for Hybrid Main Memory and Flash Memory Storages Soohyun Yang and Yeonseung Ryu Department of Computer Engineering, Myongji University Yongin, Gyeonggi-do, Korea
In-Block Level Redundancy Management for Flash Storage System
, pp.309-318 http://dx.doi.org/10.14257/ijmue.2015.10.9.32 In-Block Level Redundancy Management for Flash Storage System Seung-Ho Lim Division of Computer and Electronic Systems Engineering Hankuk University
SOS: Software-Based Out-of-Order Scheduling for High-Performance NAND Flash-Based SSDs
SOS: Software-Based Out-of-Order Scheduling for High-Performance NAND -Based SSDs Sangwook Shane Hahn, Sungjin Lee, and Jihong Kim Department of Computer Science and Engineering, Seoul National University,
Data Storage Framework on Flash Memory using Object-based Storage Model
2011 International Conference on Computer Science and Information Technology (ICCSIT 2011) IPCSIT vol. 51 (2012) (2012) IACSIT Press, Singapore DOI: 10.7763/IPCSIT.2012.V51. 118 Data Storage Framework
Empirical Inspection of IO subsystem for Flash Storage Device at the aspect of discard
, pp.59-63 http://dx.doi.org/10.14257/astl.2016.135.16 Empirical Inspection of IO subsystem for Flash Storage Device at the aspect of discard Seung-Ho Lim and Ki-Jin Kim Division of Computer and Electronic
p-oftl: An Object-based Semantic-aware Parallel Flash Translation Layer
p-oftl: An Object-based Semantic-aware Parallel Flash Translation Layer Wei Wang, Youyou Lu, and Jiwu Shu Department of Computer Science and Technology, Tsinghua University, Beijing, China Tsinghua National
Design of a High-speed and large-capacity NAND Flash storage system based on Fiber Acquisition
Design of a High-speed and large-capacity NAND Flash storage system based on Fiber Acquisition Qing Li, Shanqing Hu * School of Information and Electronic Beijing Institute of Technology Beijing, China
FAST 11. Yongseok Oh <[email protected]> University of Seoul. Mobile Embedded System Laboratory
CAFTL: A Content-Aware Flash Translation Layer Enhancing the Lifespan of flash Memory based Solid State Drives FAST 11 Yongseok Oh University of Seoul Mobile Embedded System Laboratory
Offline Deduplication for Solid State Disk Using a Lightweight Hash Algorithm
JOURNAL OF SEMICONDUCTOR TECHNOLOGY AND SCIENCE, VOL.15, NO.5, OCTOBER, 2015 ISSN(Print) 1598-1657 http://dx.doi.org/10.5573/jsts.2015.15.5.539 ISSN(Online) 2233-4866 Offline Deduplication for Solid State
A Virtual Storage Environment for SSDs and HDDs in Xen Hypervisor
A Virtual Storage Environment for SSDs and HDDs in Xen Hypervisor Yu-Jhang Cai, Chih-Kai Kang and Chin-Hsien Wu Department of Electronic and Computer Engineering National Taiwan University of Science and
Energy aware RAID Configuration for Large Storage Systems
Energy aware RAID Configuration for Large Storage Systems Norifumi Nishikawa [email protected] Miyuki Nakano [email protected] Masaru Kitsuregawa [email protected] Abstract
A Data De-duplication Access Framework for Solid State Drives
JOURNAL OF INFORMATION SCIENCE AND ENGINEERING 28, 941-954 (2012) A Data De-duplication Access Framework for Solid State Drives Department of Electronic Engineering National Taiwan University of Science
hybridfs: Integrating NAND Flash-Based SSD and HDD for Hybrid File System
hybridfs: Integrating NAND Flash-Based SSD and HDD for Hybrid File System Jinsun Suk and Jaechun No College of Electronics and Information Engineering Sejong University 98 Gunja-dong, Gwangjin-gu, Seoul
Buffer-Aware Garbage Collection for NAND Flash Memory-Based Storage Systems
Buffer-Aware Garbage Collection for NAND Flash Memory-Based Storage Systems Sungin Lee, Dongkun Shin and Jihong Kim School of Computer Science and Engineering, Seoul National University, Seoul, Korea {chamdoo,
Managing Storage Space in a Flash and Disk Hybrid Storage System
Managing Storage Space in a Flash and Disk Hybrid Storage System Xiaojian Wu, and A. L. Narasimha Reddy Dept. of Electrical and Computer Engineering Texas A&M University IEEE International Symposium on
SATA Evolves SATA Specification v3.2 FMS 2013
SATA Evolves SATA Specification v3.2 FMS 2013 SATA is Everywhere SATA is the de facto standard for PC storage Since its introduction, SATA has evolved into new application spaces and now provides storage
SSD Performance Tips: Avoid The Write Cliff
ebook 100% KBs/sec 12% GBs Written SSD Performance Tips: Avoid The Write Cliff An Inexpensive and Highly Effective Method to Keep SSD Performance at 100% Through Content Locality Caching Share this ebook
A Storage Architecture for High Speed Signal Processing: Embedding RAID 0 on FPGA
Journal of Signal and Information Processing, 12, 3, 382-386 http://dx.doi.org/1.4236/jsip.12.335 Published Online August 12 (http://www.scirp.org/journal/jsip) A Storage Architecture for High Speed Signal
Benefits of Solid-State Storage
This Dell technical white paper describes the different types of solid-state storage and the benefits of each. Jeff Armstrong Gary Kotzur Rahul Deshmukh Contents Introduction... 3 PCIe-SSS... 3 Differences
An Exploration of Hybrid Hard Disk Designs Using an Extensible Simulator
An Exploration of Hybrid Hard Disk Designs Using an Extensible Simulator Pavan Konanki Thesis submitted to the Faculty of the Virginia Polytechnic Institute and State University in partial fulfillment
NAND Flash-based Disk Cache Using SLC/MLC Combined Flash Memory
International Workshop on Storage Network Architecture and Parallel I/Os NAND Flash-based Disk Cache Using /MLC Combined Flash Memory Seongcheol Hong School of Information and Communication Engineering
Flash Memory Database (FMDB) Issues and Promising
Flash Memory Database (FMDB) Issues and Promising Nooruldeen Nasih Qader 1, Mohammed Anwar Mohammed 2, Danial Abdulkareem Muhammed 3 Department of Computer Science, University of Sulaimani, IRAQ. 1 [email protected],
Impact of Stripe Unit Size on Performance and Endurance of SSD-Based RAID Arrays
1 Impact of Stripe Unit Size on Performance and Endurance of SSD-Based RAID Arrays Farzaneh Rajaei Salmasi Hossein Asadi Majid GhasemiGol [email protected] [email protected] [email protected]
Keywords Distributed Computing, On Demand Resources, Cloud Computing, Virtualization, Server Consolidation, Load Balancing
Volume 5, Issue 1, January 2015 ISSN: 2277 128X International Journal of Advanced Research in Computer Science and Software Engineering Research Paper Available online at: www.ijarcsse.com Survey on Load
Solid State Drive Architecture
Solid State Drive Architecture A comparison and evaluation of data storage mediums Tyler Thierolf Justin Uriarte Outline Introduction Storage Device as Limiting Factor Terminology Internals Interface Architecture
Design of Remote data acquisition system based on Internet of Things
, pp.32-36 http://dx.doi.org/10.14257/astl.214.79.07 Design of Remote data acquisition system based on Internet of Things NIU Ling Zhou Kou Normal University, Zhoukou 466001,China; [email protected]
Flash for Databases. September 22, 2015 Peter Zaitsev Percona
Flash for Databases September 22, 2015 Peter Zaitsev Percona In this Presentation Flash technology overview Review some of the available technology What does this mean for databases? Specific opportunities
Choosing the Right NAND Flash Memory Technology
Choosing the Right NAND Flash Memory Technology A Basic Introduction to NAND Flash Offerings Dean Klein Vice President of System Memory Development Micron Technology, Inc. Executive Summary A 75% increase
Improving Database Performance Using a Flash-Based Write Cache
Improving Database Performance Using a Flash-Based Write Cache Yi Ou and Theo Härder University of Kaiserslautern {ou,haerder}@cs.uni-kl.de Abstract. The use of flash memory as a write cache for a database
Data Distribution Algorithms for Reliable. Reliable Parallel Storage on Flash Memories
Data Distribution Algorithms for Reliable Parallel Storage on Flash Memories Zuse Institute Berlin November 2008, MEMICS Workshop Motivation Nonvolatile storage Flash memory - Invented by Dr. Fujio Masuoka
HP Z Turbo Drive PCIe SSD
Performance Evaluation of HP Z Turbo Drive PCIe SSD Powered by Samsung XP941 technology Evaluation Conducted Independently by: Hamid Taghavi Senior Technical Consultant June 2014 Sponsored by: P a g e
OCZ s NVMe SSDs provide Lower Latency and Faster, more Consistent Performance
OCZ s NVMe SSDs provide Lower Latency and Faster, more Consistent Performance by George Crump, Lead Analyst! When non-volatile flash memory-based solid-state drives (SSDs) were introduced, the protocol
Exploiting Self-Adaptive, 2-Way Hybrid File Allocation Algorithm
Exploiting Self-Adaptive, 2-Way Hybrid File Allocation Algorithm [ Jaechun No, Sung-Soon Park ] Abstract We present hybridfs file system that provides a hybrid structure, which makes use of performance
Nasir Memon Polytechnic Institute of NYU
Nasir Memon Polytechnic Institute of NYU SSD Drive Technology Overview SSD Drive Components NAND FLASH Microcontroller SSD Drive Forensics Challenges Overview SSD s are fairly new to the market Whereas
NAND Flash & Storage Media
ENABLING MULTIMEDIA NAND Flash & Storage Media March 31, 2004 NAND Flash Presentation NAND Flash Presentation Version 1.6 www.st.com/nand NAND Flash Memories Technology Roadmap F70 1b/c F12 1b/c 1 bit/cell
Method of Fault Detection in Cloud Computing Systems
, pp.205-212 http://dx.doi.org/10.14257/ijgdc.2014.7.3.21 Method of Fault Detection in Cloud Computing Systems Ying Jiang, Jie Huang, Jiaman Ding and Yingli Liu Yunnan Key Lab of Computer Technology Application,
COS 318: Operating Systems. Storage Devices. Kai Li Computer Science Department Princeton University. (http://www.cs.princeton.edu/courses/cos318/)
COS 318: Operating Systems Storage Devices Kai Li Computer Science Department Princeton University (http://www.cs.princeton.edu/courses/cos318/) Today s Topics Magnetic disks Magnetic disk performance
OSDsim - a Simulation and Design Platform of an Object-based Storage Device
OSDsim - a Simulation and Design Platform of an Object-based Storage Device WeiYa Xi Wei-Khing For DongHong Wang Renuga Kanagavelu Wai-Kit Goh Data Storage Institute, Singapore xi [email protected]
Accelerating I/O- Intensive Applications in IT Infrastructure with Innodisk FlexiArray Flash Appliance. Alex Ho, Product Manager Innodisk Corporation
Accelerating I/O- Intensive Applications in IT Infrastructure with Innodisk FlexiArray Flash Appliance Alex Ho, Product Manager Innodisk Corporation Outline Innodisk Introduction Industry Trend & Challenge
Accelerate Oracle Performance by Using SmartCache of T Series Unified Storage
Accelerate Oracle Performance by Using SmartCache of T Series Unified Storage This document describes why and how to use SmartCache in Oracle OLTP database to accelerate the transaction performance. SmartCache
The Research and Application of College Student Attendance System based on RFID Technology
The Research and Application of College Student Attendance System based on RFID Technology Zhang Yuru, Chen Delong and Tan Liping School of Computer and Information Engineering, Harbin University of Commerce,
Last Class: OS and Computer Architecture. Last Class: OS and Computer Architecture
Last Class: OS and Computer Architecture System bus Network card CPU, memory, I/O devices, network card, system bus Lecture 3, page 1 Last Class: OS and Computer Architecture OS Service Protection Interrupts
Real Time Network Server Monitoring using Smartphone with Dynamic Load Balancing
www.ijcsi.org 227 Real Time Network Server Monitoring using Smartphone with Dynamic Load Balancing Dhuha Basheer Abdullah 1, Zeena Abdulgafar Thanoon 2, 1 Computer Science Department, Mosul University,
Research and Design of Universal and Open Software Development Platform for Digital Home
Research and Design of Universal and Open Software Development Platform for Digital Home CaiFeng Cao School of Computer Wuyi University, Jiangmen 529020, China [email protected] Abstract. With the development
Benchmarking Mobile Storage with the Arasan High Performance HVP
White Paper with the Arasan High Performance HVP Executive Summary NAND Flash is the nonvolatile memory used in virtually all mobile devices. (smartphones, tablets, cameras, game controllers). High performance
Flash Memory. Jian-Jia Chen (Slides are based on Yuan-Hao Chang) TU Dortmund Informatik 12 Germany 2015 年 01 月 27 日. technische universität dortmund
12 Flash Memory Jian-Jia Chen (Slides are based on Yuan-Hao Chang) TU Dortmund Informatik 12 Germany 2015 年 01 月 27 日 These slides use Microsoft clip arts Microsoft copyright restrictions apply Springer,
Using Synology SSD Technology to Enhance System Performance Synology Inc.
Using Synology SSD Technology to Enhance System Performance Synology Inc. Synology_SSD_Cache_WP_ 20140512 Table of Contents Chapter 1: Enterprise Challenges and SSD Cache as Solution Enterprise Challenges...
An Analysis on Empirical Performance of SSD-based RAID
An Analysis on Empirical Performance of SSD-based RAID Chanhyun Park, Seongjin Lee, and Youjip Won Department of Computer and Software, Hanyang University, Seoul, Korea {parkch0708 insight yjwon}@hanyang.ac.kr
Accelerating Enterprise Applications and Reducing TCO with SanDisk ZetaScale Software
WHITEPAPER Accelerating Enterprise Applications and Reducing TCO with SanDisk ZetaScale Software SanDisk ZetaScale software unlocks the full benefits of flash for In-Memory Compute and NoSQL applications
A Method for Load Balancing based on Software- Defined Network
, pp.43-48 http://dx.doi.org/10.14257/astl.2014.45.09 A Method for Load Balancing based on Software- Defined Network Yuanhao Zhou 1, Li Ruan 1, Limin Xiao 1, Rui Liu 1 1. State Key Laboratory of Software
Calsoft Webinar - Debunking QA myths for Flash- Based Arrays
Most Trusted Names in Data Centre Products Rely on Calsoft! September 2015 Calsoft Webinar - Debunking QA myths for Flash- Based Arrays Agenda Introduction to Types of Flash-Based Arrays Challenges in
Research of PROFIBUS PA s integration in PROFINET IO
3rd International Conference on Material, Mechanical and Manufacturing Engineering (IC3ME 2015) Research of PROFIBUS PA s integration in PROFINET IO Zhijia Yang 1, a *, Zhongsheng Li 1,2,b, Feng Qiao 2
Scalable Multiple NameNodes Hadoop Cloud Storage System
Vol.8, No.1 (2015), pp.105-110 http://dx.doi.org/10.14257/ijdta.2015.8.1.12 Scalable Multiple NameNodes Hadoop Cloud Storage System Kun Bi 1 and Dezhi Han 1,2 1 College of Information Engineering, Shanghai
Don t Let RAID Raid the Lifetime of Your SSD Array
Don t Let RAID Raid the Lifetime of Your SSD Array Sangwhan Moon Texas A&M University A. L. Narasimha Reddy Texas A&M University Abstract Parity protection at system level is typically employed to compose
Speeding Up Cloud/Server Applications Using Flash Memory
Speeding Up Cloud/Server Applications Using Flash Memory Sudipta Sengupta Microsoft Research, Redmond, WA, USA Contains work that is joint with B. Debnath (Univ. of Minnesota) and J. Li (Microsoft Research,
Design of a NAND Flash Memory File System to Improve System Boot Time
International Journal of Information Processing Systems, Vol.2, No.3, December 2006 147 Design of a NAND Flash Memory File System to Improve System Boot Time Song-Hwa Park*, Tae-Hoon Lee*, and Ki-Dong
Efficient Load Balancing using VM Migration by QEMU-KVM
International Journal of Computer Science and Telecommunications [Volume 5, Issue 8, August 2014] 49 ISSN 2047-3338 Efficient Load Balancing using VM Migration by QEMU-KVM Sharang Telkikar 1, Shreyas Talele
Indexing on Solid State Drives based on Flash Memory
Indexing on Solid State Drives based on Flash Memory Florian Keusch MASTER S THESIS Systems Group Department of Computer Science ETH Zurich http://www.systems.ethz.ch/ September 2008 - March 2009 Supervised
Using Synology SSD Technology to Enhance System Performance. Based on DSM 5.2
Using Synology SSD Technology to Enhance System Performance Based on DSM 5.2 Table of Contents Chapter 1: Enterprise Challenges and SSD Cache as Solution Enterprise Challenges... 3 SSD Cache as Solution...
MS Exchange Server Acceleration
White Paper MS Exchange Server Acceleration Using virtualization to dramatically maximize user experience for Microsoft Exchange Server Allon Cohen, PhD Scott Harlin OCZ Storage Solutions, Inc. A Toshiba
Sampling-based Metadata Management for Flash Storage
Sampling-based Metadata Management for Flash Storage Biplob Debnath, Srinivasan Krishnan, Weijun Xiao, David J. Lilja, David Du E-mail: Department of Electrical and Computer Engineering Department of Computer
Computer Organization & Architecture Lecture #19
Computer Organization & Architecture Lecture #19 Input/Output The computer system s I/O architecture is its interface to the outside world. This architecture is designed to provide a systematic means of
Flash Memory Technology in Enterprise Storage
NETAPP WHITE PAPER Flash Memory Technology in Enterprise Storage Flexible Choices to Optimize Performance Mark Woods and Amit Shah, NetApp November 2008 WP-7061-1008 EXECUTIVE SUMMARY Solid state drives
CS 377: Operating Systems. Outline. A review of what you ve learned, and how it applies to a real operating system. Lecture 25 - Linux Case Study
CS 377: Operating Systems Lecture 25 - Linux Case Study Guest Lecturer: Tim Wood Outline Linux History Design Principles System Overview Process Scheduling Memory Management File Systems A review of what
High-Performance SSD-Based RAID Storage. Madhukar Gunjan Chakhaiyar Product Test Architect
High-Performance SSD-Based RAID Storage Madhukar Gunjan Chakhaiyar Product Test Architect 1 Agenda HDD based RAID Performance-HDD based RAID Storage Dynamics driving to SSD based RAID Storage Evolution
Dynamic Load Balancing of Virtual Machines using QEMU-KVM
Dynamic Load Balancing of Virtual Machines using QEMU-KVM Akshay Chandak Krishnakant Jaju Technology, College of Engineering, Pune. Maharashtra, India. Akshay Kanfade Pushkar Lohiya Technology, College
Chapter 3 Operating-System Structures
Contents 1. Introduction 2. Computer-System Structures 3. Operating-System Structures 4. Processes 5. Threads 6. CPU Scheduling 7. Process Synchronization 8. Deadlocks 9. Memory Management 10. Virtual
NAND Flash Architecture and Specification Trends
NAND Flash Architecture and Specification Trends Michael Abraham ([email protected]) NAND Solutions Group Architect Micron Technology, Inc. August 2012 1 Topics NAND Flash Architecture Trends The Cloud
Weighted Total Mark. Weighted Exam Mark
CMP2204 Operating System Technologies Period per Week Contact Hour per Semester Total Mark Exam Mark Continuous Assessment Mark Credit Units LH PH TH CH WTM WEM WCM CU 45 30 00 60 100 40 100 4 Rationale
Flash-Friendly File System (F2FS)
Flash-Friendly File System (F2FS) Feb 22, 2013 Joo-Young Hwang ([email protected]) S/W Dev. Team, Memory Business, Samsung Electronics Co., Ltd. Agenda Introduction FTL Device Characteristics
Solid State Drive (SSD) FAQ
Solid State Drive (SSD) FAQ Santosh Kumar Rajesh Vijayaraghavan O c t o b e r 2 0 1 1 List of Questions Why SSD? Why Dell SSD? What are the types of SSDs? What are the best Use cases & applications for
Network Attached Storage. Jinfeng Yang Oct/19/2015
Network Attached Storage Jinfeng Yang Oct/19/2015 Outline Part A 1. What is the Network Attached Storage (NAS)? 2. What are the applications of NAS? 3. The benefits of NAS. 4. NAS s performance (Reliability
COS 318: Operating Systems. Storage Devices. Kai Li and Andy Bavier Computer Science Department Princeton University
COS 318: Operating Systems Storage Devices Kai Li and Andy Bavier Computer Science Department Princeton University http://www.cs.princeton.edu/courses/archive/fall13/cos318/ Today s Topics! Magnetic disks!
Caching Mechanisms for Mobile and IOT Devices
Caching Mechanisms for Mobile and IOT Devices Masafumi Takahashi Toshiba Corporation JEDEC Mobile & IOT Technology Forum Copyright 2016 Toshiba Corporation Background. Unified concept. Outline The first
Integrating Flash-based SSDs into the Storage Stack
Integrating Flash-based SSDs into the Storage Stack Raja Appuswamy, David C. van Moolenbroek, Andrew S. Tanenbaum Vrije Universiteit, Amsterdam April 19, 2012 Introduction: Hardware Landscape $/GB of flash
The Shortcut Guide to Balancing Storage Costs and Performance with Hybrid Storage
The Shortcut Guide to Balancing Storage Costs and Performance with Hybrid Storage sponsored by Dan Sullivan Chapter 1: Advantages of Hybrid Storage... 1 Overview of Flash Deployment in Hybrid Storage Systems...
