1 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes P/N Rev A07 March 07, 2012 These release notes contain information about features, system requirements, and limitations in PowerPath Version 5.6 and its minor releases for Linux. Revision history... 2 Product description... 3 New features and changes... 4 Fixed problems... 8 Environment and system requirements... 8 Known problems and limitations Technical notes Documentation Software media, organization, and files Installation Troubleshooting and getting help
2 Revision history Revision history The following table presents the revision history of this document. Revision Date Description A01 April 4, 2011 First release of this document for PowerPath 5.6 for Linux. A02 June 13, 2011 Updated the New features and changes section with the following: PowerPath Viewer support information VPLEX 5.0 support information A03 September 30, 2011 Updated for PowerPath 5.6 P01 on Oracle Linux and Oracle VM 3.0 Server. Updated the New features and changes section on page 4. Updated the Support changes section on page 7. Updated the Support Summary section on page 10. Updated the Supported Linux distributions section on page 13. Added the PowerPath and VMAX/VMAXe series devices section on page 26. A04 November 16, 2011 Depreciation announcement of support for Linux 32-bit operating systems. See Support changes on page 7. A05 December 16, 2011 Release of Linux 5.6 P02. See PowerPath 5.6 P02 on page 5. A06 December 28, 2011 Updated the Support Summary table on page 10 with VPLEX and Geosynchrony support. A07 March 07, 2012 Removed Oracle VM 3.0 Server related information. 2 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
3 Product description Product description The EMC PowerPath family of products includes: PowerPath multipathing software for physical environments, as described in PowerPath multipathing on page 3. PowerPath Migration Enabler, as described in PowerPath Migration Enabler on page 3. PowerPath Encryption with RSA, as described in PowerPath Encryption with RSA on page 4. Your license type determines the extent PowerPath functionality is available. PowerPath Migration Enabler for Encapsulation, Host Copy, Open Replicator, and TimeFinder/Clone require a separate license key. PowerPath Encryption with RSA requires a separate license key. If you have questions about your license, contact your EMC Customer Support Representative. PowerPath multipathing PowerPath is a server-resident software solution designed to enhance performance and application availability. PowerPath combines automatic load balancing, path failover, and multiple path I/O capabilities into one integrated package. PowerPath enhances application availability by providing load balancing and automatic path failover and recovery functionality. PowerPath supports servers, including cluster servers, connected to EMC and third-party arrays. PowerPath Migration Enabler EMC PowerPath Migration Enabler is a host-based migration tool that allows you to migrate data between storage systems, or in the case of EMC TimeFinder/Clone, between devices within an EMC Symmetrix storage system. PowerPath Migration Enabler uses the PowerPath filter driver, in conjunction with an underlying technology, to provide nondisruptive or minimally disruptive data migrations. EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 3
4 New features and changes The underlying technologies for Migration Enabler are EMC Encapsulation, EMC Open Replicator for Symmetrix, EMC Host Copy (host-based copy), and EMC TimeFinder/Clone. Migrations can be non-disruptive when pseudo device names are used. When native names are used, a minor disruption may be necessary to reconfigure the applications to use the target native name. PowerPath Migration Enabler works independently of PowerPath multipathing. However, PowerPath must be installed. The EMC PowerPath Migration Enabler User Guide provides additional information. PowerPath Encryption with RSA PowerPath Encryption with RSA is host-based software distributed with the PowerPath package and requiring a separate product license. PowerPath Encryption provides the following security benefits: Ensures the confidentiality of data on a disk drive that is physically removed from a data center. Prevents anyone who gains unauthorized access to the disk from reading or using the data on that device. PowerPath Encryption uses strong encryption protocols to safeguard sensitive data on disk devices. It transparently encrypts data written to a disk device and decrypts data read from it. The EMC PowerPath Encryption with RSA User Guide provides additional information. RSA Key Manager The RSA Key Manager provides key management and automatic provisioning of encryption keys for PowerPath hosts. The RSA Key Manager consists of two main elements: a central RKM appliance and distributed key manager clients (integrated into the PowerPath host). The RSA Key Manager Appliance Operations Guide provides additional information on the RKM appliance. New features and changes This section describes new features and changes by product, as follows: License ordering and activation on page 5 PowerPath multipathing on page 5 PowerPath Migration Enabler on page 7 4 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
5 New features and changes PowerPath Encryption with RSA on page 7 Support changes on page 7 Note: Earlier versions of PowerPath for Linux may be qualified with the product versions listed in this section. The E-Lab Interoperability Navigator provides complete, up-to-date qualification information. License ordering and activation Effective February 15, 2011, instead of the physical Right To Use (RTU), the default delivery method for PowerPath licenses is electronic. An electronic License Authorization Code (LAC) is sent by in order to redeem the license key on the Powerlink Licensing portal. This does not affect upgrades because PowerPath retains existing license information. Physical RTU cards are still available as an option. EMC Global Support, at svc4emc or , can provide more information. The EMC PowerPath Family Electronic License Ordering Process Technical Notes, available on Powerlink, provides more information about the PowerPath license electronic ordering process. PowerPath multipathing PowerPath 5.6 P02 PowerPath 5.6 P01 PowerPath 5.6 P02 is released to support Oracle Linux 5.x UEK kernel on x86_64 only. Other Linux platforms are not supported. PowerPath 5.6 P02 is a full-package installation. Boot from SAN support is not available on Oracle Linux 5.x running UEK kernel. PowerPath 5.6 P01 is released to support only Oracle Linux with UEK kernels on x86_64. Other Linux platforms are not supported. PowerPath 5.6 P01 is a full-package installation that includes support for the following features: Support for Oracle Linux 5.6, 6.0, and 6.1 (UEK kernels only) EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 5
6 New features and changes Note: Before installing PowerPath 5.6 P01 on a host, ensure that dm-multipath is disabled on the host. Otherwise, system instability could occur. EMC recommends that you blacklist all non-local devices on a host on which PowerPath will be installed; this action enables multipathing on those default devices. Support for Boot from SAN on Oracle Linux 6.0 and 6.1. The Boot from SAN support is not available on Oracle Linux 5.x running UEK kernel. PowerPath 5.6 PowerPath 5.6 is released to support only the Red Hat, Asianux, and Oracle Linux platforms. Other Linux platforms such as SUSE are not supported. PowerPath has the following new features: Support for EMC Symmetrix VMAXe arrays with Enginuity version e. Support for VNX Operating Environment (OE) arrays series models Support for VNXe Operating Environment (OE) arrays series models Support for RHEL 6.0 (x86, x86_64), and RHEL 5.6 (x86, x86_64) Support for Symmetrix Enginuity 5875 support Support for Invista 2.4 SP1 Support for HP StorageWorks Enterprise Virtual Array 8400 Support for Open-FCoE initiator in RHEL 6.0 Note: The Boot from SAN option is an exception for the Open-FCoE feature support. Cluster support: Support for Veritas Cluster Server 5.1, 5.1 SP1, 5.1 SP1 PR2 Support for Veritas Storage Foundation 5.1 SP1 Support for VPLEX 5.0 with GeoSynchrony 5.0 Support for PowerPath Viewer. Note: PowerPath Viewer supports only RHEL and SLES. Therefore, it is not available on PowerPath 5.6 P01, which supports only Oracle Linux platforms. 6 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
7 New features and changes PowerPath Migration Enabler PowerPath 5.6 P02 Support for Oracle Linux 5.7 UEK kernel on x86_64 only PowerPath 5.6 P01 Support for Oracle Linux 5.6, 6.0, and 6.1 UEK kernels PowerPath 5.6 Support for RHEL 6.0 (x86, x86_64), and RHEL 5.6 (x86, x86_64) PowerPath Encryption with RSA PowerPath 5.6 P02 PowerPath 5.6 P01 PowerPath 5.6 PowerPath Encryption with RSA is not supported. PowerPath Encryption with RSA is not supported. PowerPath Encryption with RSA has the following new features: Support for RHEL 5.6 (x86_64) and RHEL 6.0 (x86_64) Support changes This section includes changed behavior, end-of-life announcements, and other support changes. Operating System support: PowerPath 5.6 P01 supports Oracle Linux (UEK kernels only). It does not support Red Hat compliant kernels in Oracle Linux 5.6, 6.0, and 6.1. Deprecations PowerPath 5.6 and minor releases is the last version of PowerPath for Linux to include qualified support for 32-bit operating systems, and subsequent PowerPath for Linux releases will not support it. Earlier PowerPath for Linux versions will continue to support 32-bit operating systems. PowerPath 5.5 is the last version to support IA64 and PPC64. Earlier PowerPath for Linux versions will continue to support them. PowerPath 5.5 is the last version to support Veritas Storage Foundation 4.1. Earlier PowerPath for Linux version will continue to support it. EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 7
8 Fixed problems Fixed problems PowerPath multipathing Table 1 This section lists fixed problems by product, as follows: PowerPath multipathing on page 8 Table 1 on page 8 shows fixed problems in PowerPath multipathing. PowerPath multipathing: fixed problems Description Found in Version Fixed in Version On RHEL 5.3 server (x86_64), upgrading PowerPath in a boot-from-san configuration shows error messages emcp_mond always starts without -S option even when snmpd is configured on the RHEL host , , Upgrading PowerPath directly from versions prior to 5.1.x and earlier to version 5.3 SP1 P02 fails. The upgrade fails because PowerPath Linux 5.3 SP1 P02 uses the powermt version format=legacy command that is not available on older versions Starting PowerPath Linux 5.3 SP1 P01 HF01 b001 throws a warning about an extra line in /etc/modprobe.conf.pp. The warning is: modprobe: WARNING: /etc/modprobe.conf.pp line 7: ignoring bad line starting with 'ffffffff80154d P P SP1 P SP1 5.6 Environment and system requirements This section lists interoperability and host configuration information not found in other sources, and it provides references where you can find additional information. This section includes the following topics: E-Lab Interoperability Navigator on page 9 Support Summary on page 10 Connectivity requirements on page 15 PowerPath Migration Enabler support on page 15 8 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
9 Environment and system requirements E-Lab Interoperability Navigator For interoperability information, such as information about the hardware, software, and networked storage components that are tested and compatible with both EMC storage systems and third-party storage systems, refer to the E-Lab Interoperability Navigator, available on the Powerlink website. It also includes information about supported host models, operating system revisions, host bus adapters, and connectivity devices. Note: The information in E-Lab Interoperability Navigator takes precedence over the information in this release notice in case of inconsistency. The E-Lab Interoperability Navigator is available in two formats: The E-Lab Interoperability Navigator link is a web-based, searchable database of configuration information. Select Software Support Wizard to view support information for PowerPath and EMC arrays. The PDFs and Guides tab (within E-Lab Interoperability Navigator) lets you view support information in Adobe PDF format. Use this format to view support information for PowerPath and third-party arrays. EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 9
10 Environment and system requirements Support Summary Table 2 on page 10 summarizes support for PowerPath, PowerPath Migration Enabler, and PowerPath Encryption with RSA. Support category Cluster environments Table 2 Support summary (page 1 of 3) Technology PowerPath Migration Enabler Veritas Cluster Server (VCS) 2 Yes Yes Note: PowerPath Migration Enabler User Guide provides details of a VCS environment and the migration procedure. PowerPath Encryption 1 Yes File systems EXT2, EXT3 EXT4 (RHEL 6.0, and Oracle Linux 6.0 and 6.1 only) Yes Yes Yes 10 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
11 Environment and system requirements Support category Table 2 Support summary (page 2 of 3) Technology PowerPath Migration Enabler PowerPath Encryption 1 RHEL 5.0 to 5.4 Yes Yes No RHEL 5.5 to 5.6 Yes Yes Yes RHEL 6.0 Yes Yes Yes Note: Native devices are not supported. Asianux 3.0 GM, SP1, SP2, SP3 Yes Yes No Oracle Linux Yes Yes No Host operating systems Oracle Linux Note: PowerPath 5.6 P01 only. Yes Yes Note: Native devices are not supported. No Oracle Linux Yes Yes No Note: PowerPath 5.6 P02 only. Note: Native devices are not supported. Oracle Linux and 6.1 Yes Yes No Note: PowerPath 5.6 P01 only. Note: Native devices are not supported. Host software Solutions Enabler or later for Open Replicator Yes Yes N/A Solutions Enabler or later for TimeFinder/Clone Minimum required disk space 120 MB Note: This disk space is the total value required for PowerPath, Migration Enabler, and PowerPath Encryption. Yes Yes Yes EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 11
12 Environment and system requirements Table 2 Support summary (page 3 of 3) Support category Technology PowerPath Migration Enabler PowerPath Encryption 1 EMC storage systems 2 Yes Yes Yes EMC Invista 2.3 and later Yes Yes Yes Physical and Virtual Storage systems EMC VPLEX with GeoSynchrony 5.0.x EMC VPLEX with GeoSynchrony 4.x Note: The information in EMC Simple Support Matrix for EMC VPLEX and GeoSynchrony, available on Powerlink, takes precedence over the information in this release notice. Yes Yes 4 Yes Third-party storage arrays 2 Yes Yes 4 Yes Fibre Channel Yes Yes Yes Protocol iscsi Yes Yes 4 Yes FCoE Yes Yes 4 Yes RKM Virtually provisioned (thin) devices Volume managers RSA Key Manager (RKM) Appliance version 2.7 SP1 Requires RSA hot fix KMA-876 to support multi-clusters across distance. RKM server supports 1000 Identities, which is equivalent to PowerPath hosts. Thin device support requires: Symmetrix Enginuity Operating Environment 5773 or later. VNX OE and CLARiiON with FLARE version xx or later and the Virtual Provisioning enabler. Veritas Volume Manager (VxVM) 2 Note: Not supported on Oracle Linux 5.6, 6.0, and 6.1. N/A N/A Yes Yes Yes Yes Yes Yes Yes Linux LVM 2 Yes Yes Yes 1. x86_64 only 2. Refer to the EMC E-Lab Interoperability Navigator for details 3. Only the UEK kernels are supported 4. Host Copy only 12 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
13 Environment and system requirements Supported Linux distributions Table 3 Table 3 on page 13 provides a quick overview of each supported kernel and its corresponding PowerPath release. Supported Linux distributions PowerPath Release RHEL RHEL RHEL 6 SLES 10 SP2-10 SP4 SLES SP1 Oracle Linux 5.6 Oracle Linux 5.7 Oracle Linux P02 No No No No No No Yes No 5.6 P01 No No No No No Yes 1 No Yes No Yes Yes No No No No No 1. UEK kernels only. Kernel support Table 4 on page 13 lists the supported Linux kernels. Table 4 PowerPath 5.6 supported kernels (page 1 of 2) Distribution 1 Architecture Minimum kernel and kernel type RHEL 6 x86 kernel el6.i686 x86_64 kernel el6.x86_64 RHEL 5.6 x86 kernel el5.i686 kernel-xen el5.i686 kernel-pae el5.i686 x86_64 kernel el5.x86_64 kernel-xen el5.x86_64 2 RHEL 5.5 x86 kernel el5.i686 kernel-xen el5.i686 2 kernel-pae el5.i686 x86_64 kernel el5.x86_64 kernel-xen el5.x86_64 RHEL 5.4 x86 default el5 PAE el5 xen el5 x86_64 default el5 xen el5 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 13
14 Environment and system requirements Table 4 PowerPath 5.6 supported kernels (page 2 of 2) Distribution 1 Architecture Minimum kernel and kernel type RHEL 5.3 x86 default el5 PAE el5 xen el5 x86_64 default el5 xen el5 RHEL 5.2 x86 default el5 PAE el5 xen el5 x86_64 default el5 xen el5 RHEL 5.1 x86 default el5 PAE el5 xen el5 x86_64 default el5 xen el5 Oracle Linux 5.6 x86_64 uek el5 Oracle Linux 5.7 x86_64 uek el5uek Oracle Linux 6.0 x86_64 uek el6 Oracle Linux 6.1 x86_64 uek el6uek 1. Refer to the E-Lab Interoperability Navigator for the supported kernel revisions within this update/service pack. 2. On Xen kernel, PowerPath is supported only on the Hypervisor; and, not on the guests. Storage system configuration Before you install PowerPath, set up connections between a storage system and a host. The EMC Host Connectivity Guide for Linux describes the features and setup procedures for host interfaces to EMC Symmetrix, VNX OE and CLARiiON, Invista, and VPLEX systems. For information on setting up connections for third-party storage systems, refer to your vendor s documentation. Refer to the E-Lab Interoperability Navigator on Powerlink for supported EMC and third-party storage systems and firmware versions. 14 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
15 Environment and system requirements CLARiiON support CLARiiON customers receive PowerPath with the CLARiiON Utility Kits that ship with CLARiiON CX, CX3, CX4, and CX5-series storage systems. This version of PowerPath, referred to as PowerPath SE, provides basic failover for single HBA host configurations without the use of a license key. Important Information About PowerPath SE contains more information on the CLARiiON configurations supported by PowerPath SE. Connectivity requirements Install HBAs, supported firmware versions, and other network components using the manufacturer s directions and the settings specified in the E-Lab Interoperability Navigator. Using improper settings can cause erratic failover behavior or extended response time for system I/O. PowerPath Migration Enabler support This section includes support information for PowerPath Migration Enabler. Topics include: Migration scenarios on page 15 Migration scenarios Table 5 on page 15 describes supported migration scenarios for PowerPath Migration Enabler. Table 5 Supported migration scenarios (page 1 of 2) Source logical unit Target logical unit Technology Objects Pseudo-device name Pseudo-device name Invista Encapsulation Host Copy TimeFinder/Clone Open Replicator Requires Solutions Enabler or later EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 15
16 Environment and system requirements Table 5 Supported migration scenarios (page 2 of 2) Source logical unit Target logical unit Technology Objects Native-device name 1 Pseudo-device name Invista Encapsulation Host Copy 2 TimeFinder/Clone Open Replicator Thick plaintext Thin plaintext Host Copy 2 Thin plaintext Thin plaintext device Thick plaintext Thin plaintext device TimeFinder/Clone Open Replicator Thick plaintext device Thick plaintext device Host Copy 2 TimeFinder/Clone Open Replicator Encrypted pseudo-device name Encrypted pseudo-device name Encrypted pseudo-device name Plain text pseudo-device name Host Copy 2 Requires Symmetrix Enginuity Operating Environment 5773 or later on the Symmetrix DMX series arrays Symmetrix Enginuity Operating Environment 5874 SR on the VMAX series arrays VNX OE and CLARiiON FLARE version xx or later and the Virtual Provisioning enabler Migration Enabler detects thin devices by default and preserves the thin device allocation savings. PowerPath Encryption uses the Host Copy technology to move data to and from encrypted devices. Plaintext pseudo-device name Encrypted pseudo-device name 1. Migrations between pseudo devices is supported on all platforms that support PowerPath Migration Enabler. However, migrations from native devices to pseudo devices is supported only on RHEL 5.x. 2. On Host Copy, migrations are independent of the Symmetrix, CLARiiON, or other operating environments. 16 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
17 Known problems and limitations Known problems and limitations This section describes known problems and limitations in PowerPath Version 5.6 and its minor releases for Linux. Each table indicates the problem description, workaround, and the version in which the problem was discovered. This section includes the following topics: Known problems on page 17 Limitations on page 24 Known problems PowerPath multipathing This section includes the following tables: PowerPath multipathing on page 17 Known interoperability problems on page 21 PowerPath Migration Enabler on page 23 PowerPath Encryption with RSA: Known problems on page 24 Table 6 on page 18 shows the known problems in PowerPath multipathing. EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 17
18 Known problems and limitations Table 6 PowerPath multipathing: known problems (page 1 of 3) Description While installing PowerPath 5.6 on RHEL 6.2, the following error message is shown: emcp module is older than RHEL applying fixups Workaround No work-around. It is safe to ignore the message. Found in version Boot from SAN not supported on Oracle Linux 5.6 and 5.7 UEK. This issue is documented in EMC Knowledgebase Solution emc and in Oracle Linux Bugzilla Oracle Linux 5.6 (kernel-uek ) does not show correct information during target cable pull in a QLogic iscsi infrastructure. The "powermt display dev=all" command shows paths as alive while the target cablepull is done against the owner SP. None. 5.6 None Data corruption observed on source, target, or both after LVM operations (striping, mirroring, or snapshots) when PowerPath Encryption is in use. This issue is documented in EMC Knowledgebase Solution emc Do not use PowerPath encryption if you plan to use LVM striping, mirroring, and/or snapshots After upgrading from RHEL 5.5 to RHEL 6, and from PowerPath 5.5 to PowerPath 5.6, warning messages about configuration files appear. These warning messages appear only when starting PowerPath for the first time. No action is required The PowerPath startup script activates LVM Volume Groups that were previously inactive. This issue is documented in EMC Knowledgebase Solution emc Add the tag tag to a physical volume, volume group, or a logical volume Unlicensed VPLEX LUNs set to BasicFailover policy, show as Active in the CLI. All but two paths should show as unlicensed. None Paths may not recover from front end failure in certain scenarios. Run the following command for the HBA to rediscover the remote ports: # echo "1" > /sys/class/fc_host/host<host no>/issue_lip EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
19 Known problems and limitations Table 6 PowerPath multipathing: known problems (page 2 of 3) Description During a SP Hang, Call Trace messages are logged in the log file. After the SP comes up, a few paths remain dead even after a powermt restore. Workaround Perform the following steps as a workaround: 1. Execute the following command for all the dead paths: # echo running > /sys/block/<sda>/device/state 2. Execute the powermt restore command. Found in version For those installations booting from R2 Symmetrix devices only, PowerPath uses the INQ tool to infer SRDF pairs from system native devices information. This INQ tool requires a system semaphore sets threshold to be increased. The requirement is the same as described in Solutions Enabler documentation, Refer to Semaphores Requirement in the EMC Solutions Enabler Installation Guide for additional information. None On a RHEL5 boot-from-san setup, if the initrd image is recreated after a PowerPath installation, and if the native device name of the root disk changes, then the host will not boot up. This issue is documented in EMC Knowledgebase Solution emc After PowerPath's installation on any RHEL host, perform the following steps: 1. Make a copy of the original ramdisk image found in /boot folder. Make sure that the LVM filter in the image accepts all devices. [root@libl044 ~]# cp /boot/ initrd el5.img /boot/initrd el5.img.original 2. Create a new entry in /boot/grub/menu.lst file with the 'original' ramdisk image created in step 1 above. Now if the issue is ever encountered, then this new grub entry can be selected so that the host can boot. Then the following needs to be done so that the host can boot properly on subsequent reboots: a. Identify the new native device name of the root device. b. Recreate the default ramdisk image. 3. Recreate the default ramdisk image. 4. Reboot the host. 5.5 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 19
20 Known problems and limitations Table 6 PowerPath multipathing: known problems (page 3 of 3) Description After rebooting an Invista switch, one of the native device paths fails to come back online. Workaround 1. Run the following command for all the dead paths: echo running > /sys/block/<sda>/device/state 2. Run the following command: powermt restore Found in version In the /proc/diskstats file, IO statistics are not updated properly on partition devices for native paths. None Powermt load generates warning messages when there are dead paths or if the native device names get changed after failover Running the powermt display every=seconds when a path has failed and then restored may continue to display UNKNOWN A file system cannot be mounted after a LUN trespass and then a host reboot. PowerPath does not update the operating system partition table for the LUN because the partition table doesn t contain entries for passive paths , LCC Card & Disk Pull related issues: Paths toggle between dead and alive states before being marked dead. None Stopping the powermt display command and then starting a new session will show the updated information. Run blockdev -rereadpt on the device after the host reboot. If a rare situation does occur where the LUN toggles between dead and alive state continuously, a powermt restore command can be run to mark the device as dead. 5.3 SP2 5.3 SP EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
21 Known problems and limitations Known interoperability problems Table 7 on page 21 summarizes the known interoperability problems that affect PowerPath. Description Table 7 Known interoperability problems (page 1 of 2) Workaround Seen in version Error message is shown with LVM snapshots when the dmsetup table dm device command is run after starting either PowerPath or its host. Different format expected for the device-mapper script on RHEL6, SLES 11, or SLES 11 SP1 causes this error. This issue is documented in EMC Knowledgebase Solution emc , In non-srdf setup, starting PowerPath 5.6 consumes more than the expected time. This issue is found only when VPLEX or Invista devices are connected to the host On RHEL 6.0 and 6.1, because each calls to the udevadm settle command requires three minutes to complete, uninstalling PowerPath consumes a longer time , An issue has occurred on RHEL 5.5 with both Solutions Enabler and There is a problem releasing the locked semaphores. When running symcfg discover, the following error message is shown: The gatekeeper device (while using the Base Daemon) has an error When migrating data from a thick to a thin device with TimeFinder/Clone on a Symmetrix VMAX with Enginuity 5874, the powermig query command displays an inaccurate value for Percent InSync. This occurs because the Percent InSync value includes the area of the source device that will not be copied to the target. 1. Visit the EMC Knowledgebase Solution emc Download the pp_reset_dm_deps.sh script from the Knowledgebase Solution. 3. Replace the same script in the /etc/opt/emcpower directory with the downloaded script. 4. Follow the relevant procedure in the Knowledgebase Solution. Replace the pp_inq script with a script that contains exit 0. Install the following Selinux patches: selinux-policy-targeted el6.noarch libselinux-python el6.x86_64 selinux-policy-mls el6.noarch libselinux el6.x86_64 libselinux-devel el6.x86_64 selinux-policy-minimum el6.noarch selinux-policy el6.noarch libselinux-utils el6.x86_64 Upgrade to Solution Enabler V with T Upgrade to Symmetrix Enginuity version SP1 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 21
22 Known problems and limitations Table 7 Known interoperability problems (page 2 of 2) Description Workaround Seen in version , , On RHEL 6.0, there are slow path warnings and errors in log files for each device when restoring reconnected paths. You can ignore the error messages In a Veritas Cluster Server setup with two or more nodes, the pseudo names of the shared devices must be the same across all the nodes in the cluster. When the pseudo names are not the same, perform the following steps: 1. Run the emcpadm export_mappings command on the shared VxVM emcpower device. 2. Delete the disk.info and disk.info.old from the /etc/vx directory. 3. Import the PowerPath mapping from the other host running the emcpadm import_mappings command. 4. Perform vxdisk scandisks. An error should not occur When running scandisks for Oracle ASM volumes on PowerPath 5.1.x, the host hangs. This issue is seen with a larger number of volumes. The workaround is to execute the asmscan.sh script. This issue is documented in the EMC Knowledgebase solution emc EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
23 Known problems and limitations PowerPath Migration Enabler Table 8 Table 8 on page 23 shows the known problems in PowerPath Migration Enabler. PowerPath Migration Enabler: known problems Description Running the vxdisk scandisks command after a Host Copy migration at VxVM controlled devices shows an error message; in addition, the command does not recognize newly added LUNs , In the Open Replicator and TimeFinder/Clone migrations on RHEL6 with ext4 filesystems, the powermig commands show the following error message upon a host crash: The SYMAPI database file is invalid or corrupted With devices involved in an Open Replicator migration, when all the ports of VNX OE and CLARiiON are disabled, the paths of the Symmetrix devices involved in the migration might also go dead. Workaround 1. Remove the migrated LUNs from VxVM control. 2. Add the new LUNs on the host, if required. 3. Rescan VxVM to get new LUNs and migrated LUNs in VxVM control. Hint:Scanning the VxVM environment or a planned reboot results in application downtime. Performing both of them together could prevent additional application downtime. 1. Replace the corrupted SYMAPI database file with valid database file: # mv /var/symapi/db/symap i_db.bin /var/symapi/db/symap i_db.bin.old 2. To use the new SYMAPI database, run: # symcfg discover None Found in version SP When setting up a TimeFinder/Clone migration from a standard device to meta device, the following error message gets displayed: PPME_SYMCLONE error(182): A configuration mismatch was detected among members of your META devices.any target Meta device selected results in the error. None 5.3 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 23
24 Known problems and limitations PowerPath Encryption with RSA Table 9 Table 9 on page 24 shows the known problems in PowerPath Encryption with RSA. PowerPath Encryption with RSA: Known problems Description Workaround Found in version , Although the source data is not corrupt, mounting the snapshot, striped, or mirrored logical volume on an encrypted LUN corrupts some files on the source, target, or both. However, the error is not logged. This issue is documented in EMC Knowledgebase Solution emc None Logical Volumes on an encrypted device do not get activated when uninstalled PowerPath is reinstalled and encryption is activated / Automount of encrypted devices and Logical volumes created out of encrypted devices may not happen on hosts with /usr as a separate partition. This is because PowerPath encryption requires few libraries such as libstdc++ which are available only in /usr partition and these may not be available when PowerPath starts during system bootup. Manually activate the Logical Volumes on encrypted devices after reinstalling PowerPath. Manually mount the encrypted devices after the boot. This workaround is required only in configurations where the /usr partition is in a different disk or volume SP1 Limitations PowerPath Multipathing This section describes limitations by product: PowerPath Multipathing on page 24 PowerPath Migration Enabler on page 25 PowerPath Encryption with RSA on page 25 PowerPath 5.6 P02 does not support the following: Boot from SAN on Oracle Linux 5.7. Veritas Volume Manager on Oracle Linux 5.7 PowerPath 5.6 P01 does not support the following: Boot from SAN on Oracle Linux 5.6. Veritas Volume Manager on Oracle Linux 5.6, 6.0, and EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
25 Technical notes PowerPath Migration Enabler This section includes the limitations in PowerPath Migration Enabler. The following limitations apply only to Host Copy migrations: Host Copy supports migrating devices that exist on different transports (Fibre Channel and iscsi software initiator) or iscsi software initiator. However, when migration involves iscsi devices either as source, target, or both, host reboots are not supported. If a reboot does occur, the migration session must be aborted and then restarted. Reboots are not supported with migrations involving iscsi devices to or from encrypted devices. (Host Copy is the underlying technology used with PowerPath Encryption). PowerPath Encryption with RSA This section includes the limitations in PowerPath Encryption with RSA: PowerPath 5.6 P02 does not support PowerPath Encryption on Oracle Linux 5.7 PowerPath 5.6 P01 does not support PowerPath Encryption on Oracle Linux. LUN shrink is not supported with PowerPath Encryption enabled. A LUN shrink operation performed with encrypted devices may lead to a Data Unavailable/Data Loss scenario. Technical notes This section includes technical notes on the following topics, which are arranged as follows: PowerPath multipathing on page 26 PowerPath Migration Enabler on page 33 PowerPath Encryption with RSA on page 34 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 25
26 Technical notes PowerPath multipathing This section includes the following topics: PowerPath and VMAX/VMAXe series devices on page 26 PowerPath and VNX series devices on page 26 Setting periodic_autorestore to off still restores dead paths on page 27 Paths not released in a cluster or LVM environment on page 27 Placing Celerra iscsi devices under PowerPath control on page 27 PowerPath and the CLARiiON admsnap utility on page 28 Supporting more than 256 storage devices on page 28 Symmetrix Enginuity Operating Environment on page 30 VNX OE and CLARiiON FLARE Operating Environment on page 30 iscsi devices on page 31 Running the powermt load command may give false warning messages on page 31 Mode not reflecting properly across a reboot on page 31 Mount option in the /etc/fstab on page 32 Expanding the file system on a pseudo-device on page 32 PowerPath licenses in a CLARiiON AX and CX configuration on page 32 PowerPath Viewer support on page 32 PowerPath and VMAX/VMAXe series devices VMAX and VMAXe devices are managed under the symm storage class. This means that in powermt display, any VMAX or VMAXe devices you may have under PowerPath management appear as Symmetrix devices. Similarly, the default and licensed failover and load-balancing policies are bf for unlicensed devices and SymmOpt for licensed devices. PowerPath and VNX series devices VNX OE devices are managed under the clariion storage class. This means that in powermt display, any VNX OE devices that you may have under PowerPath management appear as CLARiiON devices. 26 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
27 Technical notes Similarly, the default unlicensed and licensed failover and load-balancing policies are the same for VNX OE devices as for CLARiiON; that is, Basic Failover for unlicensed devices and CLARopt for licensed devices. VNX devices behave like CLARiiON devices on PowerPath with respect to multipathing and failover/failback. VNXe devices are managed under the generic storage class. In powermt display, any VNXe devices that you may have under PowerPath management appear as Celerra devices. The default unlicensed failover and load-balancing policy is Basic Failover; for licensed devices, the policy is Adaptive. More information is available on the VNX OE Storage System Support website ( Setting periodic_autorestore to off still restores dead paths On some Linux platforms, when the powermt set periodic_autorestore command is set to off, PowerPath will continue to test and restore dead paths. This is an expected behavior on Oracle Linux Versions 5.6, 5.7, 6.0, and 6.1, and RHEL 6.0 kernels. Paths not released in a cluster or LVM environment In a cluster or LVM environment, host software may hold references to PowerPath or native devices. In such a situation, PowerPath cannot release one or more paths despite the device is removed or renamed. Reboot PowerPath for the host software to release these references. Placing Celerra iscsi devices under PowerPath control PowerPath treats EMC Celerra iscsi devices as generic devices. Enable generic Loadable Array Module (LAM) support so that PowerPath can recognize and manage Celerra iscsi devices. Note: For VNXe devices same procedure is applicable, including generic Loadable Array Module (LAM) support. Managing Celerra iscsi targets To place Celerra iscsi devices under PowerPath control: 1. Add the following line to the /etc/emc/mpaa.lams file: managed:generic:emc:celerra 2. Run powermt init. EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 27
28 Technical notes 3. Run powermt config. 4. Run the /etc/init.d/powerpath stop and /etc/init.d/powerpath start command sequence to restart PowerPath or reboot the host. Unmanaging Celerra iscsi targets To remove Celerra iscsi devices from PowerPath control: 1. Remove the following line from the /etc/emc/mpaa.lams file: managed:generic:emc:celerra 2. Run powermt init. 3. Run powermt config. 4. Run the /etc/init.d/powerpath stop and /etc/init.d/powerpath start command sequence to restart PowerPath or reboot the host. PowerPath and the CLARiiON admsnap utility Take note of the following if you use the CLARiiON admsnap utility with PowerPath devices. For all versions of the admsnap utility, set the PP_SHOW_CLAR_OWNING_SP environment variable to false to suppress the display of default and current SP data: PP_SHOW_CLAR_OWNING_SP=false For admsnap utility version or less: Set the PP_DEFAULT_STORAGE_SYS environment variable to VNX OE and CLARiiON to restrict the class of devices displayed by the powermt utility to VNX OE and CLARiiON devices: PP_DEFAULT_STORAGE_SYS=CLARiiON Use a native PowerPath name (for example, /dev/sde) to start or activate an admsnap session when a file system is mounted on a PowerPath device. You cannot use a PowerPath pseudo device name (for example, /dev/emcpowere) to start or activate a session when a file system is mounted on a PowerPath device. Supporting more than 256 storage devices Complete the following steps to support more than 256 storage devices on a host. 28 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
29 Technical notes Emulex HBAs If you using Emulex HBAs, set the lpfc_max_luns parameter to 1024, 2048, or4096. QLogic HBAs If you using QLogic HBAs, change the system parameters under /sys/module/scsi_mod/max_luns and max_report_luns to the recommended value. For more information, refer to the EMC Host Connectivity Guide for Linux or to the vendor website. Making the parameter settings permanent across reboot To make the parameter settings permanent across reboot on Emulex or QLogic HBAs: On RHEL 5.x 1. Edit the /etc/modprobe.conf file and set the lpfc_max_luns parameter to 1024, 2048, or Recreate the initrd. 3. Point the initrd to the new initrd when booting. On RHEL 6.x 1. Create the lpfc.conf file in the /etc/modprobe.d/ directory. 2. Edit the file and set the lpfc_max_luns parameter to Recreate the initramfs by running the dracut -f command. 4. Reboot the host. For more information, refer to the EMC Host Connectivity Guide for Linux or to the vendor website. Unmanaging more than 256 LUNs causes PowerPath loading failures. To resolve the PowerPath loading failure: 1. Type mv /etc/init.d/powerpath /etc/init.d/powerpath.orig 2. Restart the host. 3. Remove /etc/emc/mpaa.excluded. 4. Edit /etc/modprobe.conf.pp to remove the excludedvolumes module parameter and its associated arguments. 5. Type mv /etc/init.d/powerpath.orig /etc/init.d/powerpath EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 29
30 Technical notes 6. Type /etc/init.d/powerpath start. 7. Unmanage the devices (up to 256). Configuring 256 devices in a boot-from-san environment In a boot-from-san SLES environment, PowerPath configures only 256 device paths, though more device paths are available to the system. Perform the following: 1. Run /sbin/udevstart to repopulate the device directory. 2. Run powermt config. 3. Run chkconfig boot.udev on to configure udev to start up automatically on subsequent reboots. 4. Run chkconfig boot.udev to confirm the change. Symmetrix Enginuity Operating Environment Take note of the following issues regarding the Symmetrix Enginuity Operating Environment. Enginuity Operating Environment 5568 reservation and pre-emption commands The Reservation and pre-emption commands in Enginuity Operating Environment 5568 are not working according to the SCSI-3 specification. This issue is seen both with PowerPath and without PowerPath on a host. This is not a PowerPath issue. Enginuity Operating Environment 5773 and VxVM With Symmetrix Enginuity Operating Environment 5773 and VxVM, Symmetrix patch or later is required. This patch fixes an issue where the vxfentsthdw utility fails while testing a SCSI-3 persistent group reservation enabled LUN. VNX OE and CLARiiON FLARE Operating Environment Take note of the following issue regarding the VNX OE and CLARiiON FLARE Operating Environment. FLARE Operating Environment and over-provisioning After over-provisioning the thin pool on a VNX OE and CLARiiON array with FLARE version , the hosts connected to the VNX OE and CLARiiON receives SCSI related errors and does not see all the thin LUNs after a host reboot. This is a VNX OE and CLARiiON issue that has been fixed in FLARE version EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
31 Technical notes iscsi devices Take note of the following issues regarding native iscsi devices using the software initiator in a PowerPath environment. Configuring iscsi to start on host boot EMC recommends configuring your iscsi initiator service to start automatically when the host boots. Run chkconfig to enable the iscsi service. Note: If you stop PowerPath and then the device configuration changes, when you restart PowerPath you may see a message that PowerPath failed to start. You can ignore this message. Stopping iscsi on a PowerPath host Always stop PowerPath before stopping iscsi on a host with iscsi devices under PowerPath control. Note: Ensure that anything that has an iscsi device open has closed the iscsi device before shutting down iscsi. This includes file systems, volume managers, and user applications. To stop iscsi on a PowerPath host: 1. Type /etc/init.d/powerpath stop. 2. Type /etc/init.d/iscsi stop. Adding or removing iscsi devices "Dynamic LUN addition and removal" in the EMC PowerPath for Linux Installation and Administration Guide provides more information on adding or removing iscsi devices. Running the powermt load command may give false warning messages With iscsi Celerra devices, running powermt load gives a "Error occurred loading saved driver state from file /etc/powermt.custom" warning message although the configuration is restored. Because the configuration is restored, ignore the warning message. Mode not reflecting properly across a reboot When a PowerPath load balancing and failover mode is changed, the mode may not reflect properly after the reboot. This is caused by the native device name sometimes changing during the reboot, creating an incorrect configuration and is Linux operating system behavior. EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 31
32 Technical notes Mount option in the /etc/fstab RHEL 5.x and RHEL 6.x PowerPath devices should use the _netdev mount option in the /etc/fstab file for both FC, FCoE, and iscsi devices. This will ensure that fsck is run later in the boot sequence. Expanding the file system on a pseudo-device To expand the file system on a pseudo device, follow the steps below: Note: For encrypted devices, refer to "Expanding the encrypted LUN from the array side, in the PowerPath 5.6 Encryption with RSA User Guide. 1. Expand the LUN on the array. 2. Unmount the file system if it is mounted. 3. Run blockdev --rereadpt /dev/<pseudo device> to re-read the partition table of the pseudo device. 4. Follow the operating system s recommended steps to resize the file system: resize2fs p /dev/<pseudo device> for the ext2, ext3, orext4 file system. 5. Run mount /dev/<pseudo device> <Mount point>. PowerPath licenses in a CLARiiON AX and CX configuration When running PowerPath without a license on a host attached to both CLARiiON AX and CX arrays, PowerPath does not display a warning about the missing license for the CX array. This behavior may be unexpected as PowerPath does display a missing license warning when connected to CX arrays when no AX array is present. Without a license, only the AX array has full PowerPath functionality; the CX array will not have failover support. In a configuration with both CLARiiON AX and CX arrays, ensure a valid license is present for the CX array by entering emcpreg -list. PowerPath Viewer support PowerPath 5.6 and its minor releases for Linux are supported on EMC PowerPath Viewer. PowerPath Viewer can monitor the status of hosts running PowerPath 5.6 for Linux environments. EMC PowerPath Viewer is a centralized monitoring utility that provides a consolidated display of events, and allows you to view and monitor up to 500 PowerPath hosts through a graphical user interface (GUI). With EMC PowerPath Viewer, you can view hosts, 32 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
33 Technical notes host groups, LUNs, individual paths to each LUNs, and buses. PowerPath Viewer also provides alerts about any changes in the status of PowerPath devices. PowerPath Viewer includes two components: PowerPath Viewer Console, which is the interface that displays information and alerts about PowerPath custom-tailored devices shown in windows and panes; and the PowerPath Management Component, which is the host-based software that monitors host, LUNs, data path, and bus events and sends information and alerts to the Viewer Console over IP. PowerPath Viewer is available as a separate download in the PowerPath software downloads section of Powerlink. The PowerPath Viewer 1.0 and Service Pack Releases Release Notes, available on Powerlink, provides more information. PowerPath Migration Enabler This section includes the following topics: Source/target LU faults with kexec service on page 33 Symmetrix gatekeeper devices on page 33 Source/target LU faults with kexec service When kexec is enabled, Host Copy migrations with PowerPath Migration Enabler result source/target LU faults. Host that could not do a full reboot causes these faults. Therefore, when performing a Host Copy migration, if you have the kexec service running, type # chkconfig -s kexec off to disable it. Symmetrix gatekeeper devices Logical units involved in a migration should not be used as Symmetrix gatekeeper devices. To ensure that migration devices are NOT used as gatekeepers, choose at least one non-migration device and add it to the SYMAPI gkselect file (multiple gatekeeper devices can be added). This ensures that SMAPI will only use those devices as gatekeepers. The EMC Solutions Enabler Symmetrix Base Management CLI Product Guide contains more information about gatekeeper devices. EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 33
34 Technical notes PowerPath Encryption with RSA This section includes the following topics: Performance in migrations with encrypted devices on page 34 Compression issues with encrypted data for RecoverPoint on page 34 BCV device encryption on page 34 Performance in migrations with encrypted devices Migrating data to or from encrypted devices increases the CPU load on a PowerPath Encryption host since it must handle the processing load of encrypting or decrypting the data that is being migrated in addition to the normal application processing load. For information about monitoring and controlling the performance of migrations, refer to the PowerPath Migration Enabler User Guide. Compression issues with encrypted data for RecoverPoint PowerPath Encryption with RSA works with fabric-based SANTap and RecoverPoint running on a VNX OE and CLARiiON storage device. If RecoverPoint is used for remote replication, data encryption will make compression ineffective and hence a higher bandwidth will be required for encrypted devices that are being remotely replicated. BCV device encryption The following step overcomes the problem of BCV device s inability to get encrypted after the split operation with the encrypted standard device. Note: After a TimeFinder operation, updating of the BCV device encryption state is necessary. Run powervt update -dev <device_to_be_updated> to re-key the BCV device. Once the command is executed, the device would become encrypted and will be usable. 34 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
35 Documentation Documentation Table 10 Part Number Table 10 on page 35 lists the PowerPath documentation set; all manuals are available from EMC Corporation. PowerPath Family documentation set Title PowerPath Family EMC PowerPath Family Version 5.2, 5.3, 5.5, and 5.6 Product Guide EMC PowerPath Version 5.6 CLI and System Messages Reference EMC PowerPath Family for Linux Version 5.6 and Service Pack Releases Release Notes (this document) PowerPath multipathing EMC PowerPath for Linux Version 5.6 Installation and Administration Guide PowerPath Migration Enabler EMC PowerPath Migration Enabler Version 5.6 User Guide PowerPath Encryption with RSA EMC PowerPath Encryption with RSA Version 5.6 User Guide Localized versions of the EMC PowerPath for Linux Installation and Administration Guide are available in French, German, Italian, Japanese, Korean, Portuguese, simplified Chinese, and Spanish languages. PowerPath/VE for VMware vsphere is covered in the PowerPath for VMware vsphere documents, available on Powerlink. Electronic versions of all PowerPath manuals are available on the Powerlink website. These manuals are updated periodically, and the updated manuals are posted on the Powerlink website. Related Documentation The following are related documentation for Symmetrix, and VNX OE and CLARiiON storage systems. EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 35
36 Documentation Symmetrix storage systems VNX OE and CLARiiON storage systems If your environment includes Symmetrix storage systems, refer to the following: EMC Host Connectivity Guide for Linux, which provides basic information about the features and setup procedures for host interfaces to Symmetrix systems. If your environment includes VNX OE and CLARiiON storage systems, refer to the following: EMC Host Connectivity Guide for Linux, which provides basic information about the features and setup procedures for host interfaces to VNX OE and CLARiiON systems. CLARiiON Support home page: VNX OE Support home page: EMC Host Connectivity Guides, which provides basic information about the features and setup procedures for host interfaces to VNX OE and CLARiiON systems. Note: CLARiiON customers receive PowerPath with the CLARiiON Utility Kits that ship with CLARiiON CX- and CX3-series storage systems. This version of PowerPath, referred to as PowerPath SE, provides basic failover for single HBA host configurations without the use of a license key. The Important Information about PowerPath SE document, available on the Powerlink website, provides additional information on the CLARiiON configurations supported by PowerPath SE. A subset PowerPath functions are available through the Unisphere TM application for VNX OE systems. Refer to the VNX OE Storage System Support website ( A subset of PowerPath functions are available through the Navisphere and the Unisphere applications for CLARiiON systems. Refer to CLARiiON Storage-System Support website ( RSA Key Manager The following documents describe the RSA Key Manager software: RSA Key Manager Server Release Notes RSA Key Manager Server Administrator s Guide The following documents describe the RSA Key Manager appliance: RSA Key Manager Appliance Release Notes RSA Key Manager Appliance Quick Start Guide 36 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
37 Documentation This documentation is available on the product CD. If your environment includes other vendors storage systems, refer to the appropriate documentation from your vendor. End of service dates and extended support EMC has a standard software support duration policy which specifies that a major version will reach End of Service Life (EOSL) a minimum of 36 months following the General Availability (GA). EOSL may be followed by an Extended Support period during which customers may elect to pay an additional fee to extend their support coverage rather than migrate to a current software version. Once a software product reaches EOSL, EMC Technical Support is no longer available under base support/maintenance agreements. Customers interested in uninterrupted support must upgrade to a current release or contract for Extended Support (ES). Powerlink contains a list of documents that provide end-of-service and extended support information for EMC software and hardware products. To access these documents on Powerlink: 1. Go to Powerlink. 2. Enter the following text in the Search box and click Search: EMC software release end of service life 3. Find the EMC Software Release and End of Service Life Notifications document in the results. 4. Open it and search for your product and version. This document provides EOSL dates for EMC software products. Note: This policy is in effect for select releases and will be phased in as new versions are made available. In cases where a software release is not eligible for Extended Support, the previous policy, which specifies product support and maintenance under Continuous Coverage Product Maintenance (CCPM), terms still apply. EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 37
38 Software media, organization, and files Software media, organization, and files This section contains information about the PowerPath 5.6 media and files. EMC PowerPath Version 5.6 and its minor releases for Linux is a full release available on CD and for download from the Powerlink and EMC.com websites. Media and releases The PowerPath Version 5.6 and its minor releases for Linux software CD has the following structure:./linux: pp5.5.x pp5.6.x VNX./LINUX/pp5.5.x EMCPower.LINUX.5.5.GA.b275.tar.gz./LINUX/pp5.5.x/rhel EMCPower.LINUX RHEL5.i386.rpm EMCPower.LINUX RHEL5.IA64.rpm EMCPower.LINUX RHEL5.x86_64.rpm EMCPower.LINUX RHEL5.PPC64.rpm./LINUX/pp5.5.x/sles EMCPower.LINUX SLES10SP3.i386.rpm EMCPower.LINUX SLES10SP3.IA64.rpm EMCPower.LINUX SLES10SP3.x86_64.rpm EMCPower.LINUX SLES10SP3.PPC64.rpm EMCPower.LINUX SLES11SP1.i386.rpm EMCPower.LINUX SLES11SP1.x86_64.rpm EMCPower.LINUX SLES11SP1.IA64.rpm EMCPower.LINUX SLES11SP1.PPC64.rpm./LINUX/pp5.6.x EMCPower.LINUX.5.6.GA.b143.tar.gz./LINUX/pp5.6.x/rhel EMCPower.LINUX RHEL5.i386.rpm EMCPower.LINUX RHEL5.x86_64.rpm EMCPower.LINUX RHEL6.i386.rpm EMCPower.LINUX RHEL6.x86_64.rpm./LINUX/pp5.6.x/oel 38 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
39 Installation EMCPower.LINUX OL56.x86_64.rpm EMCPower.LINUX OL6.x86_64.rpm./LINUX/pp5.6.x/ovs EMCPower.LINUX OVS3.x86_64.rpm./LINUX/VNX/ PowerPath Encryption VNX Security and Compliance Suite README Table 11 on page 39 summarizes the PowerPath 5.6 package and releases. Table 11 PowerPath Version 5.6 for Linux package and releases PowerPath release/description Package/Part number Build EMC PowerPath, PowerPath Migration Enabler, and PowerPath Encryption with RSA version 5.6 for Linux software CD A01 N/A PowerPath Version 5.6 EMCPower.LINUX.5.6.GA.b143.tar.gz b143 PowerPath Version 5.6 P01 EMCPower.LINUX.5.6.P01_b005.tar.gz b005 PowerPath Version 5.6 P02 EMCPower.LINUX.5.6.P02_b001.tar.gz b001 Files For information about files added by PowerPath 5.6, refer to Files Changed By PowerPath, in the PowerPath 5.6 for Linux Installation and Administration Guide. Installation This section includes the following topics: PowerPath Configuration Checker on page 40 Installing PowerPath multipathing on page 40 Installing PowerPath Migration Enabler on page 40 Installing PowerPath Encryption with RSA on page 40 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 39
40 Installation PowerPath Configuration Checker PowerPath Configuration Checker (PPCC) is a software program that verifies that a host is configured to E-Lab Interoperability Navigator standards with the hardware and software required for PowerPath multipathing features (failover and load-balancing functions, licensing, and policies). PPCC is available for download on Powerlink. Prior to installing or upgrading PowerPath, download the latest version of EMC Grab available on Powerlink and then run PPCC. This ensures that the system version used by PPCC includes the latest configuration information. For installation information, the EMC PowerPath Configuration Checker User Guide, available on Powerlink, provides additional information. Installing PowerPath multipathing To install PowerPath follow the instructions in the EMC PowerPath for Linux Installation and Administration Guide, available on Powerlink. Upgrading PowerPath PowerPath 5.6 for Linux supports the following upgrades from: PowerPath 5.x to 5.6 RHEL 5.x to RHEL 6.0 Installing PowerPath Migration Enabler To install PowerPath Migration Enabler on Linux hosts: 1. If you have not done so already, install PowerPath Version 5.6. The EMC PowerPath for Linux Installation and Administration Guide provides additional information. 2. Install the PowerPath Migration Enabler license key and configure the Migration Enabler host. The EMC PowerPath Migration Enabler User Guide provides additional information. Installing PowerPath Encryption with RSA To install PowerPath Encryption with RSA on Linux hosts: 40 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
41 Troubleshooting and getting help 1. If you have not done so already, install PowerPath Version 5.6. The EMC PowerPath for Linux Installation and Administration Guide provides additional information. 2. Install the PowerPath Encryption with RSA license key and configure the Encryption host. The EMC PowerPath Encryption with RSA User Guide provides additional information. Troubleshooting and getting help EMC support, product, and licensing information can be obtained as follows: Product information For documentation, release notes, software updates, or for information about EMC products, licensing, and service, go to the EMC Powerlink website (registration required) at: Technical support For technical support, go to EMC WebSupport on Powerlink. To open a case on EMC WebSupport, you must be a WebSupport customer. Information about your site configuration and the circumstances under which the problem occurred is required. Service packs and upgrades You can download PowerPath service pack software from Powerlink. Determine which service packs (if any) you want to install after PowerPath, and whether those service packs have any additional installation prerequisites. To obtain service packs on Powerlink, select Support > Software Downloads and Licensing > Downloads P-R > PowerPath for Linux. Reporting a problem If you find a problem in PowerPath, run the emcgrab utility, which collects system and software configuration information. Submit the generated tar file, along with any other supporting material, to EMC Customer Support. EMC Grab 3.9 or later is required to collect information about PowerPath Encryption with RSA or Host Copy migrations. EMC Grab version 3.7 or later collects information about PowerPath Migration Enabler for Open Replicator or Invista. EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes 41
42 Troubleshooting and getting help You can download emcgrab from the Powerlink website. Select Support > Product and Diagnostic Tools > Grab Utilities. Refer to the emcgrab ReadMe.txt file on Powerlink for prerequisite information and instructions on using the utility. Copyright EMC Corporation. All rights reserved. EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED AS IS. EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. For the most up-to-date regulatory document for your product line, go to the Technical Documentation and Advisories section on EMC Powerlink. For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on EMC.com. All other trademarks used herein are t property of their respective owners. 42 EMC PowerPath Family for Linux Version 5.6 and Minor Releases Release Notes
RELEASE NOTES. Release Notes P/N 300-999-667 REV 08. EMC PowerPath and PowerPath/VE Family for Windows Version 5.7 and Minor Releases.
RELEASE NOTES EMC PowerPath and PowerPath/VE Family for Windows Version 5.7 and Minor Releases Release Notes P/N 300-999-667 REV 08 May 21, 2014 These release notes contain information about features,
EMC PowerPath and PowerPath/VE for Microsoft Windows Version 5.5 and Minor Releases
EMC PowerPath and PowerPath/VE for Microsoft Windows Version 5.5 and Minor Releases Installation and Administration Guide P/N 300-010-646 REV A05 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103
IMPLEMENTING EMC FEDERATED LIVE MIGRATION WITH MICROSOFT WINDOWS SERVER FAILOVER CLUSTERING SUPPORT
White Paper IMPLEMENTING EMC FEDERATED LIVE MIGRATION WITH MICROSOFT WINDOWS SERVER FAILOVER CLUSTERING SUPPORT Abstract This white paper examines deployment and integration of Federated Live Migration
EMC VSI for VMware vsphere: Storage Viewer
EMC VSI for VMware vsphere: Storage Viewer Version 5.6 Product Guide P/N 300-013-072 REV 07 Copyright 2010 2013 EMC Corporation. All rights reserved. Published in the USA. Published September 2013 EMC
Windows Host Utilities 6.0.2 Installation and Setup Guide
Windows Host Utilities 6.0.2 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277
IMPROVING VMWARE DISASTER RECOVERY WITH EMC RECOVERPOINT Applied Technology
White Paper IMPROVING VMWARE DISASTER RECOVERY WITH EMC RECOVERPOINT Applied Technology Abstract EMC RecoverPoint provides full support for data replication and disaster recovery for VMware ESX Server
Linux Host Utilities 6.1 Installation and Setup Guide
Linux Host Utilities 6.1 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP
Windows Host Utilities 6.0 Installation and Setup Guide
Windows Host Utilities 6.0 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP
EMC Support Matrix. Interoperability Results. P/N 300 000 166 ECO 36106 Rev B30
EMC Support Matrix Interoperability Results P/N 300 000 166 ECO 36106 Rev B30 Table of Contents Copyright EMC Corporation 2006...1 EMC's Policies and Requirements for EMC Support Matrix...2 Selections...4
EMC PowerPath Family
DATA SHEET EMC PowerPath Family PowerPath Multipathing PowerPath Migration Enabler PowerPath Encryption with RSA The enabler for EMC host-based solutions The Big Picture Intelligent high-performance path
Validating Host Multipathing with EMC VPLEX Technical Notes P/N 300-012-789 REV A01 June 1, 2011
Validating Host Multipathing with EMC VPLEX Technical Notes P/N 300-012-789 REV A01 June 1, 2011 This technical notes document contains information on these topics: Introduction... 2 EMC VPLEX overview...
VMware Site Recovery Manager with EMC RecoverPoint
VMware Site Recovery Manager with EMC RecoverPoint Implementation Guide EMC Global Solutions Centers EMC Corporation Corporate Headquarters Hopkinton MA 01748-9103 1.508.435.1000 www.emc.com Copyright
AX4 5 Series Software Overview
AX4 5 Series Software Overview March 6, 2008 This document presents an overview of all software you need to configure and monitor any AX4 5 series storage system running the Navisphere Express management
RELEASE NOTES. Release Notes P/N 300-012-821 REV 12. EMC Storage Integrator for Windows Suite Version 3.5. July 2014
RELEASE NOTES EMC Storage Integrator for Windows Suite Version 3.5 Release Notes P/N 300-012-821 REV 12 July 2014 These release notes contain information for the following topics: Revision history... 2
Setup for Failover Clustering and Microsoft Cluster Service
Setup for Failover Clustering and Microsoft Cluster Service ESX 4.0 ESXi 4.0 vcenter Server 4.0 This document supports the version of each product listed and supports all subsequent versions until the
SAN Implementation Course SANIW; 3 Days, Instructor-led
SAN Implementation Course SANIW; 3 Days, Instructor-led Course Description In this workshop course, you learn how to connect Windows, vsphere, and Linux hosts via Fibre Channel (FC) and iscsi protocols
ASM_readme_6_10_18451.txt -------------------------------------------------------------------- README.TXT
README.TXT Adaptec Storage Manager (ASM) as of June 3, 2009 Please review this file for important information about issues and erratas that were discovered after completion of the standard product documentation.
OneCommand Manager Application for the Drivers for Linux Release Notes
OneCommand Manager Application for the Drivers for Linux Release Notes Version: 5.2.12.2-1 System: SLES 10 SP3 and SP4 (X86, X64 and PPC) SLES 11 SP1 (X86, X64, IA64 and PPC) RH 5.5(X86, X64, IA64 and
EMC CLARiiON Asymmetric Active/Active Feature
EMC CLARiiON Asymmetric Active/Active Feature A Detailed Review Abstract This white paper provides an overview of the EMC CLARiiON Asymmetric Active/Active feature. It highlights the configuration, best
EMC Invista: The Easy to Use Storage Manager
EMC s Invista SAN Virtualization System Tested Feb. 2006 Page 1 of 13 EMC Invista: The Easy to Use Storage Manager Invista delivers centrally managed LUN Virtualization, Data Mobility, and Copy Services
EMC POWERPATH MIGRATION ENABLER HOST COPY
White Paper EMC POWERPATH MIGRATION ENABLER HOST COPY A Detailed Review Abstract This white paper focuses on EMC PowerPath Migration Enabler Host Copy, which is entirely host-based. As with other versions
IBRIX Fusion 3.1 Release Notes
Release Date April 2009 Version IBRIX Fusion Version 3.1 Release 46 Compatibility New Features Version 3.1 CLI Changes RHEL 5 Update 3 is supported for Segment Servers and IBRIX Clients RHEL 5 Update 2
EMC Symmetrix with Microsoft Windows Server 2003 and 2008
Best Practices Planning Abstract This white paper outlines the concepts, procedures, and best practices associated with deploying Microsoft Windows Server 2003 and 2008 with EMC Symmetrix DMX-3 and DMX-4,
Setup for Failover Clustering and Microsoft Cluster Service
Setup for Failover Clustering and Microsoft Cluster Service Update 1 ESXi 5.1 vcenter Server 5.1 This document supports the version of each product listed and supports all subsequent versions until the
EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, Symmetrix Management Console, and VMware vcenter Converter
EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, VMware vcenter Converter A Detailed Review EMC Information Infrastructure Solutions Abstract This white paper
SAN Conceptual and Design Basics
TECHNICAL NOTE VMware Infrastructure 3 SAN Conceptual and Design Basics VMware ESX Server can be used in conjunction with a SAN (storage area network), a specialized high speed network that connects computer
1. Revision Page 1. 1. Revision Page 1
1. Revision Page 1 Note: This document contains support information for only the 3 most recent versions of Hitachi Dynamic Link Manager Advanced. If you require support for previous versions, please ask
Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide
Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:
Veritas CommandCentral Disaster Recovery Advisor Release Notes 5.1
Veritas CommandCentral Disaster Recovery Advisor Release Notes 5.1 Veritas CommandCentral Disaster Recovery Advisor Release Notes Copyright 2009 Symantec Corporation. All rights reserved. Product version:
Storage Management for the Oracle Database on Red Hat Enterprise Linux 6: Using ASM With or Without ASMLib
Storage Management for the Oracle Database on Red Hat Enterprise Linux 6: Using ASM With or Without ASMLib Sayan Saha, Sue Denham & Lars Herrmann 05/02/2011 On 22 March 2011, Oracle posted the following
readme_asm.txt -------------------------------------------------------------------- README.TXT
README.TXT Adaptec Storage Manager as of March 27, 2006 Please review this file for important information about issues and erratas that were discovered after completion of the standard product documentation.
Configuring Linux to Enable Multipath I/O
Configuring Linux to Enable Multipath I/O Storage is an essential data center component, and storage area networks can provide an excellent way to help ensure high availability and load balancing over
An Integrated End-to-End Data Integrity Solution to Protect Against Silent Data Corruption
White Paper An Integrated End-to-End Data Integrity Solution to Protect Against Silent Data Corruption Abstract This white paper describes how T10 PI prevents silent data corruption, ensuring that incomplete
EMC Replication Manager for Virtualized Environments
EMC Replication Manager for Virtualized Environments A Detailed Review Abstract Today s IT organization is constantly looking for ways to increase the efficiency of valuable computing resources. Increased
EMC PowerPath Family. Product Guide. Version 5.7 P/N 300-014-261 REV 04
EMC PowerPath Family Version 5.7 Product Guide P/N 300-014-261 REV 04 Copyright 1997 2014, EMC Corporation. All rights reserved. Published in the USA. Published January 2014 EMC believes the information
EMC Symmetrix V-Max and Microsoft SQL Server
EMC Symmetrix V-Max and Microsoft SQL Server Applied Technology Abstract This white paper examines deployment and integration of Microsoft SQL Server solutions on the EMC Symmetrix V-Max Series with Enginuity.
Veritas Dynamic Multipathing Administrator's Guide
Veritas Dynamic Multipathing Administrator's Guide Linux 5.1 Rolling Patch 1 DMP Veritas Dynamic Multipathing Administrator's Guide The software described in this book is furnished under a license agreement
Hardware Compatibility List
Symantec Storage Foundation and High Availability Solutions 6.0, 6.0 Platform Release 1 (Solaris), 6.0.1, 6.0.2 (Linux), 6.0.3, 6.0.4 (Linux), 6.0.5 and Dynamic Multi-Pathing for VMware 6.0, 6.0.1 Hardware
readme.txt -------------------------------------------------------------------- README.TXT
README.TXT Adaptec Storage Manager (ASM) as of August 11, 2010 Please review this file for important information about issues and erratas that were discovered after completion of the standard product documentation.
Installation and Support Guide for Microsoft Windows Server, Linux, Novell NetWare, and VMware ESX Server
System Storage DS3000 Storage Manager Version 10 Installation and Support Guide for Microsoft Windows Server, Linux, Novell NetWare, and VMware ESX Server System Storage DS3000 Storage Manager Version
Setup for Failover Clustering and Microsoft Cluster Service
Setup for Failover Clustering and Microsoft Cluster Service Update 1 ESX 4.0 ESXi 4.0 vcenter Server 4.0 This document supports the version of each product listed and supports all subsequent versions until
EMC MIGRATION OF AN ORACLE DATA WAREHOUSE
EMC MIGRATION OF AN ORACLE DATA WAREHOUSE EMC Symmetrix VMAX, Virtual Improve storage space utilization Simplify storage management with Virtual Provisioning Designed for enterprise customers EMC Solutions
EMC Symmetrix V-Max with Veritas Storage Foundation
EMC Symmetrix V-Max with Veritas Storage Foundation Applied Technology Abstract This white paper details the benefits of deploying EMC Symmetrix V-Max Virtual Provisioning and Veritas Storage Foundation
HP Matrix Operating Environment 7.2 Recovery Management User Guide
HP Matrix Operating Environment 7.2 Recovery Management User Guide Abstract The HP Matrix Operating Environment 7.2 Recovery Management User Guide contains information on installation, configuration, testing,
VERITAS Storage Foundation 4.3 for Windows
DATASHEET VERITAS Storage Foundation 4.3 for Windows Advanced Volume Management Technology for Windows In distributed client/server environments, users demand that databases, mission-critical applications
Fibre Channel SAN Configuration Guide ESX Server 3.5, ESX Server 3i version 3.5 VirtualCenter 2.5
Fibre Channel SAN Configuration Guide ESX Server 3.5, ESX Server 3i version 3.5 VirtualCenter 2.5 This document supports the version of each product listed and supports all subsequent versions until the
Deploying Global Clusters for Site Disaster Recovery via Symantec Storage Foundation on Infortrend Systems
Deploying Global Clusters for Site Disaster Recovery via Symantec Storage Foundation on Infortrend Systems Application Notes Abstract: This document describes how to apply global clusters in site disaster
-------------------------------------------------------------------- README.TXT
README.TXT Adaptec Storage Manager (ASM) as of September 17, 2007 Please review this file for important information about issues and erratas that were discovered after completion of the standard product
Dell High Availability Solutions Guide for Microsoft Hyper-V
Dell High Availability Solutions Guide for Microsoft Hyper-V www.dell.com support.dell.com Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer.
EMC RepliStor for Microsoft Windows ERROR MESSAGE AND CODE GUIDE P/N 300-002-826 REV A02
EMC RepliStor for Microsoft Windows ERROR MESSAGE AND CODE GUIDE P/N 300-002-826 REV A02 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2003-2005
Setup for Failover Clustering and Microsoft Cluster Service
Setup for Failover Clustering and Microsoft Cluster Service ESXi 5.0 vcenter Server 5.0 This document supports the version of each product listed and supports all subsequent versions until the document
Veritas Storage Foundation and High Availability Solutions Getting Started Guide
Veritas Storage Foundation and High Availability Solutions Getting Started Guide Linux 5.1 Service Pack 1 Platform Release 2 Veritas Storage Foundation and High Availability Solutions Getting Started Guide
N_Port ID Virtualization
A Detailed Review Abstract This white paper provides a consolidated study on the (NPIV) feature and usage in different platforms and on NPIV integration with the EMC PowerPath on AIX platform. February
Cisco Active Network Abstraction Gateway High Availability Solution
. Cisco Active Network Abstraction Gateway High Availability Solution White Paper This white paper describes the Cisco Active Network Abstraction (ANA) Gateway High Availability solution developed and
Introduction to MPIO, MCS, Trunking, and LACP
Introduction to MPIO, MCS, Trunking, and LACP Sam Lee Version 1.0 (JAN, 2010) - 1 - QSAN Technology, Inc. http://www.qsantechnology.com White Paper# QWP201002-P210C lntroduction Many users confuse the
InForm OS 2.2.3/2.2.4 VMware ESX Server 3.0-4.0 QLogic/Emulex HBA Implementation Guide
InForm OS 2.2.3/2.2.4 VMware ESX Server 3.0-4.0 QLogic/Emulex HBA Implementation Guide InForm OS 2.2.3/2.2.4 VMware ESX Server 3.0-4.0 FC QLogic/Emulex HBA Implementation Guide In this guide 1.0 Notices
Hardware and Software Interoperability Matrix
Hardware and Software Interoperability Matrix This document provides interoperability matrices for Cisco Unified Computing components and configurations that have been tested and validated by Cisco, by
EMC Solutions for Disaster Recovery
EMC Solutions for Disaster Recovery EMC RecoverPoint Daniel Golic, Technology Consultant Banja Luka, May 27 th 2008 1 RecoverPoint 3.0 Overview 2 The CIO s Information Storage and Management Requirements
Network-based Intelligent Data Protection Yossi Mossel, Product Manager
1 EMC RecoverPoint Network-based Intelligent Data Protection Yossi Mossel, Product Manager The CIO s Information-Storage and -Management Requirements Lower TCO Utilization, consolidation, automated management
Veritas Dynamic Multi-Pathing for Windows Release Notes
Veritas Dynamic Multi-Pathing for Windows Release Notes Windows Server 2008 (x64), Windows Server 2008 R2 (x64) 6.0.1 October 2012 Veritas Dynamic Multi-Pathing for Windows Release Notes The software described
HP Serviceguard for Linux Certification Matrix
HP Serviceguard for Linux Certification Matrix Note: Going forward this document can be accessed from http://h20195.www2.hp.com/v2/getdocument.aspx?docname=c02829576& cc=us&lc=en. Please update your bookmarks
Veritas Storage Foundation and High Availability Solutions HA and Disaster Recovery Solutions Guide for Enterprise Vault
Veritas Storage Foundation and High Availability Solutions HA and Disaster Recovery Solutions Guide for Enterprise Vault Windows Server 2003 Windows Server 2008 5.1 Service Pack 2 Veritas Storage Foundation
Setup for Microsoft Cluster Service ESX Server 3.0.1 and VirtualCenter 2.0.1
ESX Server 3.0.1 and VirtualCenter 2.0.1 Setup for Microsoft Cluster Service Revision: 20060818 Item: XXX-ENG-QNNN-NNN You can find the most up-to-date technical documentation on our Web site at http://www.vmware.com/support/
Direct Storage Access Using NetApp SnapDrive. Installation & Administration Guide
Direct Storage Access Using NetApp SnapDrive Installation & Administration Guide SnapDrive overview... 3 What SnapDrive does... 3 What SnapDrive does not do... 3 Recommendations for using SnapDrive...
ENTERPRISE LINUX SYSTEM ADMINISTRATION
ENTERPRISE LINUX SYSTEM ADMINISTRATION The GL250 is an in-depth course that explores installation, configuration and maintenance of Linux systems. The course focuses on issues universal to every workstation
EMC POWERPATH LOAD BALANCING AND FAILOVER
White Paper EMC POWERPATH LOAD BALANCING AND FAILOVER Comparison with native MPIO operating system solutions Abstract EMC PowerPath and PowerPath/VE provide intelligent load balancing and failover. This
-------------------------------------------------------------------- README.TXT
README.TXT Adaptec Storage Manager (ASM) as of June 7, 2007 Please review this file for important information about issues and erratas that were discovered after completion of the standard product documentation.
Direct Attached Storage
, page 1 Fibre Channel Switching Mode, page 1 Configuring Fibre Channel Switching Mode, page 2 Creating a Storage VSAN, page 3 Creating a VSAN for Fibre Channel Zoning, page 4 Configuring a Fibre Channel
How To Use A Microsoft Networker Module For Windows 8.2.2 (Windows) And Windows 8 (Windows 8) (Windows 7) (For Windows) (Powerbook) (Msa) (Program) (Network
EMC NetWorker Module for Microsoft Applications Release 2.3 Application Guide P/N 300-011-105 REV A03 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright
Virtual Storage Console 4.0 for VMware vsphere Installation and Administration Guide
Virtual Storage Console 4.0 for VMware vsphere Installation and Administration Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support
Netapp Interoperability Matrix
Netapp Interoperability Matrix FC, FCoE, iscsi and NAS (NFS) Storage Interoperability The Interoperability Matrix (IMT) defines the components and versions that have been qualified and which can be used
Symantec NetBackup Clustered Master Server Administrator's Guide
Symantec NetBackup Clustered Master Server Administrator's Guide for Windows, UNIX, and Linux Release 7.5 Symantec NetBackup Clustered Master Server Administrator's Guide The software described in this
EMC Business Continuity for VMware View Enabled by EMC SRDF/S and VMware vcenter Site Recovery Manager
EMC Business Continuity for VMware View Enabled by EMC SRDF/S and VMware vcenter Site Recovery Manager A Detailed Review Abstract This white paper demonstrates that business continuity can be enhanced
VERITAS NetBackup 6.0 High Availability
VERITAS NetBackup 6.0 High Availability System Administrator s Guide for UNIX, Windows, and Linux N152848 September 2005 Disclaimer The information contained in this publication is subject to change without
EMC Backup and Recovery for Microsoft SQL Server 2008 Enabled by EMC Celerra Unified Storage
EMC Backup and Recovery for Microsoft SQL Server 2008 Enabled by EMC Celerra Unified Storage Applied Technology Abstract This white paper describes various backup and recovery solutions available for SQL
Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4
Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4 Application Note Abstract This application note explains the configure details of using Infortrend FC-host storage systems
Parallels Virtuozzo Containers 4.7 for Linux
Parallels Virtuozzo Containers 4.7 for Linux Deploying Clusters in Parallels-Based Systems Copyright 1999-2011 Parallels Holdings, Ltd. and its affiliates. All rights reserved. Parallels Holdings, Ltd.
Oracle VM Server Recovery Guide. Version 8.2
Oracle VM Server Recovery Guide Version 8.2 Oracle VM Server for x86 Recovery Guide The purpose of this document is to provide the steps necessary to perform system recovery of an Oracle VM Server for
Managing Microsoft Hyper-V Server 2008 R2 with HP Insight Management
Managing Microsoft Hyper-V Server 2008 R2 with HP Insight Management Integration note, 4th Edition Introduction... 2 Overview... 2 Comparing Insight Management software Hyper-V R2 and VMware ESX management...
PS Series Storage Array - Configuration, Operation and Management
Course Title: PS Series Storage Array - Configuration, Operation and Management The Partner Technical Training PS Series Storage Array - Configuration, Operation and Management course provides the opportunity
EMC Navisphere Manager ADMINISTRATOR S GUIDE P/N 069001125 REV A12
EMC Navisphere Manager ADMINISTRATOR S GUIDE P/N 069001125 REV A12 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508 -435-1000 www.emc.com Copyright 2003-2005 EMC Corporation. All
vsphere Upgrade vsphere 6.0 EN-001721-03
vsphere 6.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions of this document,
RED HAT ENTERPRISE VIRTUALIZATION
Giuseppe Paterno' Solution Architect Jan 2010 Red Hat Milestones October 1994 Red Hat Linux June 2004 Red Hat Global File System August 2005 Red Hat Certificate System & Dir. Server April 2006 JBoss April
How To Manage Your Volume On Linux 2.5.5 (Evms) 2.4.5 On A Windows Box (Amd64) On A Raspberry Powerbook (Amd32) On An Ubuntu Box (Aes) On Linux
www.suse.com/documentation Storage Administration Guide SUSE Linux Enterprise Server 10 SP3/SP4 March 6, 2011 Legal Notices Novell, Inc. makes no representations or warranties with respect to the contents
Storage Pool Management Feature in EMC Virtual Storage Integrator
Storage Pool Management Feature in EMC Virtual Storage Integrator Version 4.0 Installation and Configuration of SPM Detailed Use Cases Customer Example Drew Tonnesen Lee McColgan Bill Stronge Copyright
FlexArray Virtualization
Updated for 8.2.1 FlexArray Virtualization Implementation Guide for Third-Party Storage NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support
Veritas Storage Foundation High Availability for Windows by Symantec
Veritas Storage Foundation High Availability for Windows by Symantec Simple-to-use solution for high availability and disaster recovery of businesscritical Windows applications Data Sheet: High Availability
HiCommand Dynamic Link Manager (HDLM) for Windows Systems User s Guide
HiCommand Dynamic Link Manager (HDLM) for Windows Systems User s Guide MK-92DLM129-13 2007 Hitachi Data Systems Corporation, ALL RIGHTS RESERVED Notice: No part of this publication may be reproduced or
EMC NetWorker Module for Microsoft Applications
EMC NetWorker Module for Microsoft Applications Release 2.3 Installation Guide P/N 300-011-101 REV A02 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright
HIGHLY AVAILABLE MULTI-DATA CENTER WINDOWS SERVER SOLUTIONS USING EMC VPLEX METRO AND SANBOLIC MELIO 2010
White Paper HIGHLY AVAILABLE MULTI-DATA CENTER WINDOWS SERVER SOLUTIONS USING EMC VPLEX METRO AND SANBOLIC MELIO 2010 Abstract This white paper demonstrates key functionality demonstrated in a lab environment
EMC FEDERATED TIERED STORAGE (FTS) Allows Seamless Integration Between EMC Symmetrix VMAX Series and Third-Party Storage Arrays
White Paper EMC FEDERATED TIERED STORAGE (FTS) Allows Seamless Integration Between EMC Symmetrix VMAX Series and Third-Party Storage Arrays Abstract This white paper describes the external provisioning
Setup for Failover Clustering and Microsoft Cluster Service
Setup for Failover Clustering and Microsoft Cluster Service ESXi 5.5 vcenter Server 5.5 This document supports the version of each product listed and supports all subsequent versions until the document
Citrix XenServer-6.2 Administration Training
Citrix XenServer-6.2 Administration Training Course Duration : 20Days Class Duration : 3hours per day ( Fast Track Course duration 7days Per day 8 hours ) Classroom Training Fast-Track Training: - Online
HP VMware ESXi 5.0 and Updates Getting Started Guide
HP VMware ESXi 5.0 and Updates Getting Started Guide Abstract This guide is intended to provide setup information for HP VMware ESXi. HP Part Number: 616896-002 Published: August 2011 Edition: 1 Copyright
Virtual Machine Backup Guide
Virtual Machine Backup Guide ESX 4.0, ESXi 4.0 Installable and vcenter Server 4.0, Update 2 and later for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5 This document supports the version
FioranoMQ 9. High Availability Guide
FioranoMQ 9 High Availability Guide Copyright (c) 1999-2008, Fiorano Software Technologies Pvt. Ltd., Copyright (c) 2008-2009, Fiorano Software Pty. Ltd. All rights reserved. This software is the confidential
Support Notes for SUSE LINUX Enterprise Server 9 Service Pack 3 for the Intel Itanium 2 Processor Family
Support Notes for SUSE LINUX Enterprise Server 9 Service Pack 3 for the Intel Itanium 2 Processor Family *5991-5301* Part number: 5991-5301 Edition: 3, E0406 Copyright 2006 Hewlett-Packard Development
EMC VPLEX: LEVERAGING ARRAY BASED AND NATIVE COPY TECHNOLOGIES
White Paper EMC VPLEX: LEVERAGING ARRAY BASED AND NATIVE COPY TECHNOLOGIES Second Edition Abstract This white paper provides best practices planning and use cases for using array-based and native replication
EMC NetWorker Module for Microsoft Applications Release 2.3. Application Guide P/N 300-011-105 REV A02
EMC NetWorker Module for Microsoft Applications Release 2.3 Application Guide P/N 300-011-105 REV A02 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright