DSL INSTRUCTION MANUAL
|
|
|
- Charlotte Summers
- 10 years ago
- Views:
Transcription
1 DSL INSTRUCTION MANUAL 7010 Lindsay Dr., Mentor, OH Phone: U.S./Canada: FAX: Certified to ISO 9001:2008, including design Revision - Date: 02-02/20/13 30
2 CONTENTS Model Identification / Installation...2 Wiring...3 Wiring for Transmitter Inputs Wiring for 15 VDC Outputs Wiring for Optional Inputs and Outputs Front Panel Key Functions...6 The Home Display Diagnostic Error Messages...8 Notation Conventions for the Menus...11 Menu Selections...11 Primary Menu...11 Secondary Menu...11 Operation and Programming of Options...12 Secure Menu...15 Alarm Type and Action...23 Operation of Self Tune Function...25 Theory of Operation...26 Specifications...27 Dimensions...29 Revision - Date: 02-02/20/13 1
3 MODEL IDENTIFICATION DSL designation Model 16A *037 Standard Alarm high, low, absolute or deviation Heat (reverse acting) Cool (direct acting) Input 1000 ohm 2 wire RTD, convertible to thermocouple, DC volts, DC amps Model 16A *037-( ) RS -232 serial port for customer supplied software -485 com port for optional ProTrac software or customer supplied software Model 16A *037 MAC Similar to Standard above except, 0-20 ma current control output Model 16A *037 VC Similar to Standard above except, 15 VDC control output Model 16A *037-( ) VR -ma Temperature retransmission, 4-20 ma -VDC Temperature retransmission, 0 to 10 VDC INSTALLATION Mount the instrument in a location that will not be subject to excessive temperature, shock, or vibration. All models are designed for mounting in an enclosed panel. Select the position desired for the instrument on the panel. If more than one instrument is required, clearance allowances for mounting collar access should be considered as shown below. Prepare the panel by cutting and deburring the required opening. Revision - Date: 02-02/20/13 2 DIAGRAM 1
4 From the front of the panel, slide the housing through the cutout. The housing gasket should be against the housing flange before installing. From the rear of the panel, slide the mounting collar over the housing. Hold the housing with one hand and using the other hand, push the collar evenly against the panel until the spring loops are slightly compressed. The ratchets will hold the mounting collar and housing in place. PANEL 6.35 mm (0.25 ) MAX. GASKET SPRING LOOP MOUNTING COLLAR (SHOWN IN POSITION) SLIDE COLLAR ONTO THE HOUSING BEFORE WIRING THE REAR TERMINALS DIAGRAM 2 WIRING Do not run thermocouple or other signal wiring in the same conduit as power leads. Use only the type of thermocouple or RTD probe for which the control has been programmed. Maintain separation between wiring of sensor, auxiliary in or out, and other wiring. See the Secure Menu for input selection. For thermocouple input, always use extension leads of the same type designated for your thermocouple. For 2 wire RTD sensors, supply a jumper between terminals 3 & 4. For supply connections, use No. 16 AWG or larger wires rated for at least 75 C. Use copper conductors only. All line voltage output circuits must have a common disconnect and be connected to the same pole of the disconnect. Input wiring for thermocouple, current, and RTD; and output wiring for current and 15 VDC is rated CLASS 2. Control wiring is as shown. Revision - Date: 02-02/20/13 3
5 DIAGRAM 3 DIAGRAM 4 Wiring for 4 to 20mA Transmitter Inputs Wire power and outputs as shown above. Two-wire transmitters wire as shown on the following page. For three or four wire transmitters follow, the wiring instructions provided with your transmitter. Revision - Date: 02-02/20/13 4
6 DIAGRAM 5 Wiring for Optional Inputs and Outputs Wire power and outputs as shown on previous pages. All wiring shown below is Class 2. Shielded twisted pair is required for RS-485 option. DO NOT RUN SIGNAL WIRING IN THE SAME CONDUIT OR CHASE AS THE POWER WIRING. ERRATIC OPERATION OR CONTROL DAMAGE WILL RESULT. DIAGRAM 6 Revision - Date: 02-02/20/13 5
7 FRONT PANEL KEY FUNCTIONS Alarm Lamp Set Point 1 Lamp Process Display Set Point Display Set Point 2 Lamp Remote Set Lamp F Indicator C Indicator Per Cent Lamp Index Up Arrow Down Arrow DIAGRAM 7 Enter Keys are illuminated when pressed. Key functions are as follows: INDEX: Pressing the INDEX key advances the display to the next menu item. May also be used in conjunction with other keys as noted. For the primary menu (factory default), you will advance through the SP1, SP2 and AlHi settings. UP ARROW: Increments (increases) a value, changes a menu item, or selects the item to ON. The maximum value obtainable is 9999, regardless of decimal point placement. DOWN ARROW: Decrements (decreases) a value, changes a menu item, or selects the item to OFF. The minimum value obtainable is -1999, regardless of decimal point placement. ENTER: Pressing ENTER stores (updates) the value or the item changed. If not pressed, the previously stored value or item will be retained. The display will flash once when ENTER is pressed. Revision - Date: 02-02/20/13 6
8 UP ARROW & ENTER: Pressing these keys simultaneously brings up the secondary menu starting at the PEA, UAL, SP1d, etc. Pressing these keys for 5 seconds will bring up the secure menu. INDEX & DOWN ARROW: Pressing these keys simultaneously will allow backing up one menu item, or if at the first menu item, they will cause the display to return to the primary menu. If an alarm condition has occurred, these keys may be used to reset the alarm. To reset an alarm, press and hold both keys for three seconds. INDEX & ENTER: Pressing these keys simultaneously and holding them for 5 seconds allows recovery from the various error messages. The following menu items will be reset: ALiH: Alarm inhibit bad InP: Input error message OPEn InP: Input error message CHEC CAL: Check calibration error Correct the problems associated with the above conditions before using these reset keys. More than one error could be present. Caution is advised, since several items are reset at one time. THE HOME DISPLAY The home display is the normal display while the control is operating. If no errors or functions are active, the HOME display will indicate the Process Variable (the temperature, pressure, flow, RH, etc., that is being measured) on the top display and the Set Variable (Set Point 1) on the bottom. If PctO (Secure Menu) is turned On, the lower display changes to show the active percentage of output as required to maintain SP1 and SP2. The value displayed is no longer the SV, but percent output. The SP2 output is indicated by the use of an overline on the letter o. Access to the SP1 or SP2 value is done by the INDEX key. If the control has both SP1 and SP2, the lower display will alternate between the SP1 percent output and the SP2 percent output. Error messages are listed on the following two pages. Revision - Date: 02-02/20/13 7
9 Revision - Date: 02-02/20/13 8
10 Revision - Date: 02-02/20/13 9
11 While in the Primary or Secondary Menu, if no key is pressed for a period of 30 seconds, the display will return to the HOME position displaying the temperature value. While in the Secure Menu, if no key is pressed for a period of 60 seconds, the display will return to the HOME position displaying the temperature value. Outputs are disabled (turned off) when the Secure Menu is active. NOTE: To move to the Primary Menu quickly from any other menu, press the UP ARROW & ENTER keys followed by pressing the INDEX & DOWN ARROW keys. SECURITY LEVEL SELECTION Four levels of security are provided. Selecting a specific security level will inhibit casual access by operating personnel wishing to alter various programmed parameters. Accessing the security level menu will display the current security level. To change security levels, change the password value using the UP & DOWN ARROW keys and pressing the ENTER key. Refer to the password table (following) for the correct value to enter for the security level desired. The SECr menu item security level may be viewed or changed at any time regardless of the present security level. The factory setting is security level 2. To the access the security level and change it to, for example, 3, press and hold for at least 4 seconds the UP ARROW and ENTER keys simultaneously. The SECr menu will appear indicating the current security level. Press the UP ARROW key until the upper display indicates Press the ENTER key. The display will blink and will indicate the new security level, 3, in the upper display. The password values shown in the table cannot be altered, so retain a copy of these pages for future reference. This is the only reference made to password values in this instruction book. Security Level Displayed Value Password Value Menu Status When Accessed To Enter Primary Locked Secondary Locked Secure Locked Primary Unlocked Secondary Locked Secure Locked Primary Unlocked Secondary Unlocked Secure Locked Primary Unlocked Secondary Unlocked Secure Unlocked Revision - Date: 02-02/20/13 10
12 NOTATION CONVENTIONS FOR THE MENUS Because of the number of features available in this control, information is included that may not apply to your specific control. All usable features are included in this book, but may not be used in your process. To increase clarity, the following conventions are used: 1. Certain features, menu items, and functions shown in this book may or may not appear on your control, depending on other menu Item selections. At various places in the menus there are notes identifying menu items that control or direct other menu items. If you are looking for a particular menu item and can t find it, check the menu item that is its control for proper setting. 2. The # symbol is used in two ways. It is used inside a group of characters to indicate which set point function (SP1 or SP2) is being affected. It is also used before a group of characters of a menu item to indicate that there may be more than one selection or value for that menu item. 3. Features that apply only to Options will be printed in italics. MENU SELECTIONS PRIMARY MENU Press INDEX to advance to the next menu item. Press UP ARROW or DOWN ARROW to change the value in the display. Press ENTER to retain the value. #SP1 (optional 4-Stage Set Point) or SP1 Set Point 1 Adjust, Control Point 1. SP2 Set Point 2 Adjust, Control Point 2. AlLo Alarm Low: The Low Alarm point is usually set below the Set Point. Alarm Low will not appear unless selected at AL1 setting in Secure Menu. AlHi Alarm High: The High Alarm Point is usually set above the Set Point. SECONDARY MENU Hold UP ARROW & ENTER. Press INDEX to advance to the next menu item. Press UP ARROW or DOWN ARROW to change the value in the display. Press ENTER to retain the value. PEA The Peak feature stores the highest input the control has measured since the last reset or Power On. At Power On, PEA is reset to the present input. To manually reset the value, PEA must be in the lower display. Press the ENTER key to reset. PEA will be reset and display the present input value. UAL The Valley feature stores the lowest input the Instrument has measured since the last reset or Power On. At Power On, UAL is reset to the present input. To manually reset the value, UAL must be in the lower display. Press the ENTER key. UAL will be reset and display the present input value. Revision - Date: 02-02/20/13 11
13 SP#d Set Point On-Off Differential (hysteresis). Select 1 to 9999 (direct acting), or -1 to (reverse acting). This value will be negative for reverse acting set points, and positive for direct acting outputs. Set the value for the amount of difference between the turn off point (set point) and the turn on point. The following drawing shows output behavior for reverse and direct action. DIAGRAM 8 InPC Input Correction: Select ±0-500 F, C, or counts. This feature allows the input value to be changed to agree with an external reference or to compensate for sensor error. Note: InPC is reset to zero when the input type is changed, or when decimal position is changed. OPTIONS VR Option, Isolated Temperature Retransmission. The analog retransmission option allows the Process Variable or the Set Variable to be sent as an analog signal to an external device. The signal may be either 0 to 10 VDC (Option VDC) or 0 (or 4) to 20 madc (Option ma). The output may be changed in the field from one to the other by the toggle switch located on the top printed circuit board. Wire the output as shown on page 5. To set up the analog retransmission, first determine the scale range that the analog signal will represent. The maximum scale is 9999 F, 5530 C, or 9999 counts. In the Secondary Menu set POL for the scale value that will be represented by the low end of the analog signal (0 Volts or 0 ma). Set POH for the scale value that will be represented by the high end of the analog signal (10 Volts or 20 ma). If you require a suppressed scale or output, you may use the following equations to determine the proper settings for POL and POH. K = (Highest desired scale reading - Lowest desired scale reading) (Maximum desired analog signal - Minimum desired analog signal). POH = (Maximum possible analog output - Maximum desired analog signal X K) + Highest desired scale reading. POL = Lowest desired scale reading - (Minimum desired analog output X K). Revision - Date: 02-02/20/13 12
14 Example Span of F with a 4-20mA ouput K = (500-0)/(20-4) = POH = ((20-20) X 31.25) = +500 POL = 0-(4 X 31.25) = -125 Next, select whether you want the retransmission signal to follow the Process Variable or the Set Variable. Usually the Process Variable is sent to recorders or other data acquisition devices. Usually the Set Variable is sent to other controls to be used as an analog remote set point. If you want the analog retransmission signal to follow the PV, in the Secondary Menu set POSr to InP. If you want the analog retransmission signal to follow the SV, set POSr to SPt. Operation is automatic. There are no further programming steps required. 4-Stage Set Point The 4-stage set point option allows four different values to be used for SP1 and all of the values associated with the tune menu items. The control will switch to a given stage when an external contact or contacts are made or opened across the appropriate terminals at the rear of the control (when SPSA, Set Point Switch Action, is set for remote, re), or when the stage is selected from the Secondary Menu, SP (when SPSA is set for Int). When the state of a contact changes (or the stage number is changed in the Secondary Menu), the values in use are stored and the previously stored values for the new stage are used. Wire the input as shown on page 5, diag. 6. Usually the control is configured for external switching of the stages. In this case, the operation is usually automatic, selected by the external switches driven by the machine logic. If it is necessary to program the stages in advance, you may select the stage to modify with the SP menu item. When SP is changed while the SPSA is set for re, the selected stage is displayed for modification, but only used when the appropriate contact is made. RS Option, Serial Communication. The serial communications options allow the control to be written to and read from a remote computer or other similar digital device. Communication is allowed either through an RS-485 (Option 485) port, or an RS-232 (Option 232) port. Wire the communication lines as shown on Page 5, diag. 6. Wiring for the RS-485 is run from control to control in a daisy chain fashion with a termination resistor (120 ohms) across the transmit and receive terminals of the last control in the chain. A RS485/232 transceiver and PROTRAC software package are available for purchase if you do not have your own software. Revision - Date: 02-02/20/13 13
15 Select the control address and communication baud rate with the Addr and baud menu items in the Secure Menu. THE BAUD RATE AND AD- DRESS MENU ITEMS WILL TAKE EFFECT ON THE NEXT POWER UP OF THE CONTROL. BE SURE TO POWER CYCLE THE CONTROL BEFORE USING THE NEW BAUD RATE AND ADDRESS. In operation, you have the option of preventing a write command from the host computer. To prevent the host from writing to the control, change the LOrE menu item in the Secondary Menu to LOC. To allow the host to write commands to the control, set LOrE to re. (The host does have the ability to change the LOrE state, but it is not automatic.) If your system depends on constant reading or writing to and from the host, you may wish to set the No Activity Timer (nat) to monitor the addressing of the control. When the LOrE is set to re and the nat is set to any value other than Off, the control will expect to be addressed on a regular basis. If the control is not addressed in the time set by the value of nat, then the control will display the error message CHEC LOrE. To clear the message, set LOrE to LOC. The following menu items apply only if your control is equipped with a 4 stage set point option. SP (4-Stage Set Point) Active Set Point Stage. Select 1SP1, 2SP1, 3SP1, 4SP1. 1SP1 Set Menu Items to display Stage 1 for view and change access. If SPSA is set for Int, 1SP1 is made active. 2SP1 Set Menu Items to display Stage 2 for view and change access. If SPSA is set for Int, 2SP1 is made active. 3SP1 Set Menu Items to display Stage 3 for view and change access. If SPSA is set for Int, 3SP1 is made active. 4SP1 Set Menu Items to display Stage 4 for view and change access. If SPSA is set for Int, 4SP1 is made active. The following menu items apply only if your control is equipped with the VR option. POL POH POSr (Analog Retransmission Output) Process Output Low: Select 1999 counts to any value less than POH. (Analog Retransmission Output) Process Output High: Select from any value greater than POL to 9999 counts. (Analog Retransmission Output) Process Output Source: Select InP or SPt. InP Process Output follows the Process Variable (input). SPt Process Output follows the Set Variable (SP1). Revision - Date: 02-02/20/13 14
16 The following menu item applies only if your control is equipped with the remote set point option. rspt rsch (Analog Remote Set Point) Remote Set Point: Select On or OFF. OFF The control uses the value set for SP1. On The control uses the value set by the analog remote set point signal as established by the Secure Menu items rscl and If the analog signal fails, the control will display the error message CHEC/ LorE and revert to the SP1 local value. The following menu items apply only if your control is equipped with the RS option. LOrE Addr (Serial Communications) Local / Remote Status: Select LOC or re. LOC The host computer is advised not to send remote commands. Any write commands sent to the controls will be rejected. re The host computer is allowed to send write commands. If the control is not addressed within the time set in the nat (No Activity Timer, see Secure Menu), the CHEC LorE error message will be displayed. (Serial Communications) Control Address: Set from 1 to 3FF. This number (hexadecimal, base 16) must match the address number used by the host computer. Viewed only in this menu. To change this parameter, see Addr in the Secure Menu. SECURE MENU Hold UP ARROW & ENTER for 5 Seconds. Press INDEX to advance to the next menu item. Press UP ARROW or DOWN ARROW to change the value in the display. Press ENTER to retain the value. OUTPUTS ARE DISABLED (TURNED OFF) WHILE CONTROL IS IN SECURE MENU. SECr Security Code: See the Security Level Selection and the Password Table on page 10 of this manual in order to enter the correct password. Note: The menu items for tune (below) are modified when 4 Stage Set Point is in use. When 4 Stage Set Point is active, the menu items are preceded with the stage number selected in SP above. The stage number is noted here with the # sign. When the 4 Stage Set Point option is active, each stage has its own set of tune parameters. #tun (4-Stage Set Point) or tune Tuning Choice: Select SELF, Pid, SLO, nor, or FASt. Revision - Date: 02-02/20/13 15
17 Pid2 ArUP SELF The Controller will evaluate the Process and select the PID values to maintain good control. Active for SP1 only. LErn Select YES or no YES Start Learning the Process. After the process has been learned, the menu item will revert to no. no Learning will stay in present mode. dfac Damping factor, Select OFF, 1 to 7. Sets the ratio of Rate to Reset for the SELF tune mode. 7 = most Rate. Factory set to 3. For a fast response process, the value should be lowered (less Rate). For a slower process, the value should be increased (more Rate). Pid Manually adjust the PID values. PID control consists of three basic parameters: Proportional Band (Gain), Reset Time (Integral), and Rate Time (Derivative). #Pb1 (4-Stage Set Point) or Pb1 Proportional Band (Bandwidth). Select 1 to 9999 F, C, or counts. Pb2 Proportional Band (Bandwidth). Select 1 to 9999 F, C, or counts. Appears only if control is equipped with second set point and Out2 is NOT selected as ONOF. #res (4-Stage Set Point) or res Automatic Reset Time. Select OFF, 0.1 to 99.9 minutes. Select OFF to switch to OFS. #OFS (4-Stage Set Point) or OFS Manual Offset Correction Select OFF, 0.1 to 99.9%. Select OFF to switch to res. #rte (4-Stage Set Point) or rte Rate Time. Select OFF, 0.01 to minutes, derivative. SLO PID values are preset for a slow response process. nor PID values are preset for a normal response process. FASt PID values are preset for a fast response process. Linkage of PID parameters between SP1 and SP2: Select On or OFF. On Applies SP1 res, rte, Fbnd, and FrtE terms to SP2 for heat/cool applications. OFF SP2 functions without res, rte, Fbnd and FrtE. Anti- Reset Windup Feature: Select On or OFF. On When ArUP is On the accumulated Reset Offset value Revision - Date: 02-02/20/13 16
18 will be cleared to 0% when the process input is not within the Proportional Band. OFF When ArUP is OFF, the accumulated Reset Offset Value is retained in memory when the process input is not within the Proportional Band. ArtE Approach Rate Time: Select OFF, 0.01 to minutes. The function defines the amount of Rate applied when the input is outside of the Proportional Band. The ArtE time and the rte time are independent and have no effect on each other. To increase damping effect and reduce overshoot, set the approach rate time for a value greater than the natural rise time of the process (natural rise time = process value time to set point). Fint Fuzzy Logic Intensity: Select 0 to 100%. 0% is OFF (disables Fuzzy Logic). The function defines the amount of impact Fuzzy Logic will have on the output. Fbnd Fuzzy Logic Error Band: Select 0 to 4000 F, C, or counts. Sets the bandwidth of the Fuzzy Logic. Set Fbnd equal to PID proportional band (Pb1) for best results. FrtE Fuzzy Logic Rate of Change: Select 0.00 to counts/second. For best initial setting, find the degrees/second change of process value near set point with output at 100%. Multiply this value by 3. Set FrtE to this calculated value. PctO Percent Output Feature: Select On or OFF. On When selected On, the HOME lower display will indicate the output of the controller in percent. An o will appear in the right hand side of the lower display to indicate percent output for SP1. An o will appear on the right hand corner of the lower display to represent percent output for SP2, if the control is so equipped. The display will alternate between these values. OFF Percent Output display is disabled. InP Input Type: Select one of the following. Refer to the Input wiring section for the proper wiring. J-IC Type J Thermocouple, Iron/Constantan (NIST) CA Type K Thermocouple Chromel/Alumel E- Type E Thermocouple Chromel/Constantan t- Type T Thermocouple Copper/Constantan L- Type L Thermocouple Iron/Constantan (DIN) n- Type N Thermocouple Nicrosil/Nisil r-13 Type R Thermocouple Pt 13%Rh/Pt S-10 Type S Thermocouple Pt 10%Rh/Pt b- Type B Thermocouple Pt 6%Rh/Pt 30%Rh C- Type C Thermocouple W 5%Re/W 26%Re P ohm Platinum (NIST W/W/ C) RTD n ohm Nickel RTD Revision - Date: 02-02/20/13 17
19 P ohm Platinum (DIN W/W/ C) RTD 1P ohm Platinum (DIN W/W/ C) RTD Curr DC Current Input 0.0 to 20.0 or 4.0 to 20.0 ma VoLt DC Voltage Input 0.0 to 5.0 or 1.0 to 5.0 volts diff DC Voltage Input -10 to +10 mv Reserved OSUP Zero Suppression: Select On or OFF. Only with Current and Voltage input types. OFF The input range will start at 0 (zero) Input. On The input range will start at 4.00 ma or 1.00 V. Unit F, C or none. F F descriptor is On and temperature inputs will be displayed in actual degrees Fahrenheit. C C descriptor is On and temperature inputs will be displayed in actual degrees Celsius. none F and C descriptors will be Off. This is only available with Current and Voltage Inputs. dpt Decimal Point Positioning: Select 0, 0.0, 0.00, 0.000, or On temperature type inputs, this will only effect the Process Value, SP1, SP2, ALLo, ALHi, and InPC. For Current and Voltage Inputs, all Menu Items related to the Input will be affected. 0 No decimal point is selected. This is available for all Input Types. 0.0 One decimal place is available for Type J, K, E, T, L, RTDs, Current and Voltage Inputs Two decimal places is only available for Current and Voltage Inputs Three decimal places is only available for Current and Voltage inputs Four decimal places is only available for Current and Voltage inputs. InPt Input Fault Timer: Select OFF, 0.1 to minutes. Whenever an Input is out of range (UFL or OFL displayed), shorted, or open the timer will start. When the time has elapsed, the controller will revert to the output condition selected by InPb below. If OFF is selected, the Input Fault Timer will not be recognized (time = infinite). If resolution is selected, this should be increased to 4. If this value is set too high, controllability will suffer. InPb Input Fail Action: Select FAIL, AVE or PrE. When the INput is out of range (UFL or OFL displayed) and the Input timer (InPt) time has elapsed, the controller will revert to the selected condition. FAIL Outputs are disabled (go to 0% output). AVE The outputs will hold the last known average percentage of output. PrE The outputs will maintain a preprogrammed percentage Revision - Date: 02-02/20/13 18
20 of output as specified in PrE1 and PrE2. PrE1 Preset output for Set Point 1. Select 0 to 100%. PrE2 Preset output for Set Point 2. Select 0 to 100%. SEnC Sensor Rate of Change: Select OFF, 1 to 4000 F, C, or counts per 1 second period. This value is usually set to be slightly greater than the fastest process response expected during a 1 second period, but measured for at least 2 seconds. If the process is faster than this setting, the SEnC bad error message will appear. The outputs will then be turned off. This function can be used to detect a runaway condition, or speed up detection of an open thermocouple. Use the INDEX & ENTER keys to reset. FiLt Digital Filter: Select OFF, 1 to 99. In some cases the time constant of the sensor, or noise, could cause the display to jump enough to be unreadable. A setting of 2 is usually sufficient to provide enough filtering for most cases (2 represents approximately a 1 second time constant). When the 0.1 degree resolution is selected, this should be increased to 4. If this value is set too high, controllability will suffer. SCAL Scale Low: Select 100 to 9999 counts below SCAH. The total span between SCAL and SCAH must be within counts. Maximum setting range is to counts. For Current and Voltage inputs, this will set the low range end. Viewable (cannot be changed) only for Thermocouple and RTD ranges. SCAH Scale High: Select 100 to 9999 counts above SCAL. The total span between SCAL and SCAH must be within counts. Maximum setting range is to counts. For Current and Voltage inputs, this will set the high range end. Viewable (cannot be changed) only for Thermocouple and RTD ranges. SPL Set Point Low: Select from the lowest input range value to SPH value. This will set the minimum SP1 or SP2 value that can be entered. The value for SP1 or SP2 will not stop moving when this value is reached. SPH Set Point High: Select from the highest input range value to SPL value. This will set the maximum SP1 or SP2 value that can be entered. The value for SP1 or SP2 will not stop moving when this value is reached. SP1O Set Point 1 Output Select: Select OutA or Outb. OutA Set Point 1 is routed through Output A, Set Point 2 (if equipped) is routed through Output B. Outb Set Point 1 is routed through Output B, Set Point 2 (if equipped) is routed through Output A. Out1 Output selection: Select OnOf, 1tP, 1PuL, or ProP. ONOF A setting of ONOF allows the control to operate as a simple on/off mode. This setting forces the control to turn off at set point, and on at the set point plus the differential Revision - Date: 02-02/20/13 19
21 S1St S1OL S1OH ##tp (SP_d). When selected, the Out1/OnOF menu item is followed by ####/SP1d, and the tune, Pb, res, OFS, rte, and ArUP selections in the Secondary menu and the S1OL and S1OH selections in the Secure menu are suppressed. Time Proportioning Cycle Time. Select 1tP to 80tP. 1tP A setting of 1tP is recommended for solid state outputs (SSR or 15VDC). 2tP to 80tP Time Proportioning Control is adjustable in 1 second steps. Recommended for mechanical outputs (relays, solenoids, etc.). For best contact life, a time should be selected as long as possible without causing the process to wander. #PuL Pulsed Time Proportioning Output: Select 1PuL to 7PuL. 1PuL = Linear and 7PuL = most nonlinear. Changes output linearity for use in cooling applications or for an extremely fast response processes. At the center of the proportional band, a pulse value of 1 provides an output of one second on and one second off (50% output). A pulse value of 2 provides an output of one second on and two seconds off (33% output). Output at center of band equals one second on, 2 (pulse value-1) seconds off. ProP For Current (Code 5) outputs only. Set Point 1 State: Select dir or re. dir Direct Action. As the input increases, the output will increase. Most commonly used in cooling processes. re Reverse Action. As the input increases, the output will decrease. Most commonly used in heating processes. If Out1 is set for ##tp, #PUL, or ProP, then S1OL and S1OH (following) appear. If Out1 is set for ONOF, then skip to S1rE. Set Point Output Low Limit: Select 0 to 100% but not greater than S1OH. This item limits the lowest output value. This is useful for adding a bias to the process when needed. Factory set to 0 for output codes 1,2, and 3. Factory set to 20 for output code 5 (20% output equals 4 ma output). Set Point 1 Output High Limit: Select 0 to 100% but not less than S1OL for output codes 1, 2, or 3. Select 0 to 102% but not less than S1OL for output code 5. This item allows setting the maximum output limit. This is useful with processes that are over powered. Adjustment to 102% allows setting current output to force a full ON condition for output devices which do not have bias adjustments. Factory set to 100 for all output codes. Revision - Date: 02-02/20/13 20
22 If Out1 is set for ##tp, #PUL, or ProP, then skip to S1LP below. S1rE S1Pi S1iH S1LP Set Point 1 Reset. Select OnOF or Hold. OnOF Control will automatically reset when process passes back through SP1d. HoLd Manual Reset. Reset (acknowledge) by simultaneously pressing the INDEX & DOWN ARROW keys for 5 seconds. Set Point 1 Power Interrupt. Select On or OFF. On Alarm Power Interrupt is On. Control will automatically reset on power-up if no alarm condition exists. OFF Alarm Power Interrupt is OFF. Control will power-up in alarm condition regardless of condition of process. Set Point 1 Inhibit: Select On or OFF. On Alarm Inhibit is On. Alarm action is suspended until the process value first enters a non-alarm condition. OFF Alarm Inhibit is OFF. Set Point Lamp: Select O on or OoFF. O on Lamp ON when Output is ON. OoFF Lamp OFF when Output is ON. If your control is not equipped with Set Point 2, then proceed to the alarm section (page 23). S2t Out2 Set Point 2 type: Select Abs or de. AbS Absolute SP2. SP2 is independent of SP1, and may be set anywhere between the limits of SPL and SPH. de Deviation SP2. SP2 is set as a deviation from SP1, and allows SP2 to retain its relationship with SP1 when SP1 is changed (tracking SP2). Output selection: Select OnOf, 2tP, 2PuL, or ProP. ONOF A setting of ONOF allows the control to operate as a simple on/off mode. This setting forces the control to turn off at set point, and on at the set point plus the differential (SP2d). When selected, the Out2/OnOF menu item is followed by ####/SP2d, and the Pb2 selection in the Secondary menu and the S2OL and S2OH selections in the Secure menu are suppressed. SP2d Set Point On-Off Differential (hysteresis). Select 1 to 9999 (direct acting), or -1 to (reverse acting). This value will be negative for reverse acting set points, and positive for direct acting outputs Set the value for the amount of difference between the turn off point (set point) and the turn on point. Diagram 8 on page 12 shows output behavior for reverse and direct action. Revision - Date: 02-02/20/13 21
23 ##tp Time Proportioning Cycle Time. Select 1tP to 80tP. 1tP A setting of 1tP is recommended for solid state outputs (15VDC). 2tP to 80tP Time Proportioning Control is adjustable in 1 second steps. Recommended for mechanical outputs (relays, solenoids, etc.). For best contact life, a time should be selected as long as possible without causing the process to wander. #PuL Pulsed Time Proportioning Output: Select 1PuL to 7PuL. 1PuL = Linear and 7PuL = most nonlinear. Changes output linearity for use in cooling applications or for extremely fast response processes. At the center of the proportional band, a pulse value of 1 provides an output of one second on and one second off (50% output). A pulse value of 2 provides an output of one second on and two seconds off (33% output). Output at center of band equals one second on, 2 (pulse value-1) seconds off. ProP For Current (Code 5) outputs only. S2St Set Point 2 State: Select dir or re. dir Direct Action. As the input increases, the output will increase. Most commonly used in cooling processes. re Reverse Action. As the input increases, the output will decrease. Most commonly used in heating processes. If Out2 is set for ##tp, #PUL, or ProP, then S2OL and S2OH (following) appear. If Out2 is set for ONOF, then skip to S2rE. S2OL Set Point Output Low Limit: Select 0 to 100% but not greater than S2OH. This item limits the lowest output value. This is useful for adding a bias to the process when needed. Factory set to 0 for output codes 1,2, and 3. Factory set to 20 for output code 5 (20% output equals 4 ma output). S2OH Set Point 1 Output High Limit: Select 0 to 100% but not less than S2OL for output codes 1, 2, or 3. Select 0 to 102% but not less than S2OL for output code 5. This item allows setting the maximum output limit. This is useful with processes that are over powered. Adjustment to 102% allows setting current output to force a full ON condition for output devices which do not have bias adjustments. Factory set to 100 for all output codes. S2rE Set Point 2 Reset. Select OnOF or Hold. OnOF Control will automatically reset when process passes back through SP2d. HoLd Manual Reset. Reset (acknowledge) by simultaneously pressing the INDEX & DOWN ARROW keys for 5 seconds. Revision - Date: 02-02/20/13 22
24 S2Pi S2iH S2LP Set Point 2 Power Interrupt. Select On or OFF. On Alarm Power Interrupt is On. Control will automatically reset on power-up if no alarm condition exists. OFF Alarm Power Interrupt is OFF. Control will power-up in alarm condition regardless of condition of process. Set Point 2 Inhibit: Select On or OFF. On Alarm Inhibit is On. Alarm action is suspended until the process value first enters a non-alarm condition. OFF Alarm Inhibit is OFF. Set Point 2 Lamp: Select O on or OoFF. O on Lamp ON when Output is ON. OoFF Lamp OFF when Output is ON. ALARM TYPE AND ACTION (if present) Caution: In any critical application where failure could cause expensive product loss or endanger personal safety, a redundant limit controller is required. When setting an alarm value for an absolute alarm (A#t = AbS), simply set the value at which the alarm is to occur. When setting the alarm value for a deviation alarm (A#t = de), set the difference in value from the Set Point (SP) desired. For example, if a low alarm is required to be 5 degrees below the SP, then set A#Lo to -5. If a high alarm is required 20 degrees above the SP, then set A#Hi to +20. If SP is changed, the alarm will continue to hold the same relationship as originally set. The diagram below shows the action and reset functions for both absolute and deviation alarms. DIAGRAM 9 Revision - Date: 02-02/20/13 23
25 When Alarm Power Interrupt, A#Pi, is programmed ON and Alarm Reset, A#rE, is programmed for Hold, the alarm will automatically reset upon a power failure and subsequent restoration if no alarm condition is present. If Alarm Inhibit, A#iH, is selected ON, an alarm condition is suspended upon power up until the process value passes through the alarm set point once. Alarm inhibit can be restored as if a power up took place by pressing both the INDEX and ENTER keys for 5 seconds. Warning: Resetting a high alarm inhibit will not cause an alarm to occur if the Process Value does not first drop below the high alarm setting. Do not use the Alarm Inhibit feature if a hazard is created by this action. Be sure to test all combinations of high and low alarm inhibit actions before placing control into operation. The following menu items apply only to the alarm. AL1 Alarm 1 function: Select OFF, Lo, Hi, HiLo, or Evnt. OFF Alarm 1 is disabled. No Alarm 1 menu items appear in the Secondary or Secure menus. Lo Low Alarm Only. A1Lo appears in the Secondary Menu. Hi High Alarm Only. A1Hi appears in the Secondary Menu. HiLo High and Low Alarms. Both A1Lo and A1Hi appear in the Secondary Menu, and share the same Alarm 1 Relay output. Evnt Alarm 1 is controlled by an external event. If AL1 is set to OFF and the control is not equipped with options, the Secure Menu ends. If AL1 is set to OFF and the control is equipped with options, proceed to SPSA, Addr, or rscl below. If AL1 is set to Evnt, go to A1St. A1t Alarm 1 Type: Select AbS or de AbS Absolute Alarm that may be set anywhere within the values of SCAL and SCAH and is independent of SP1. de Deviation Alarm that may be set as an offset from SP1. As SP1 is changed the Alarm Point will track with SP1. A deviation alarm will also track any active ramp or soak set point. A1rE Alarm 1 Reset: Select OnOF or Hold. OnOF Automatic Reset. Hold Manual Reset. Reset (acknowledge) by simultaneously pressing the INDEX & DOWN ARROW keys for 5 seconds. A1Pi Alarm 1 Power Interrupt: Select On or OFF. On Alarm Power Interrupt is On. OFF Alarm Power Interrupt is OFF. A1iH Alarm 1 Inhibit: Select On or OFF. On Alarm Inhibit is On. Alarm action is suspended until the process value first enters a non-alarm condition. OFF Alarm Inhibit is OFF. A1St Alarm 1 Output State: Select CLOS or OPEn. Revision - Date: 02-02/20/13 24
26 CLOS Closes Contacts at Alarm Set Point. OPEn Opens Contacts at Alarm Set Point. A1LP Alarm 1 Lamp: Select O on or OoFF. O on Alarm Lamp is ON when alarm contact is closed. OoFF Alarm Lamp is OFF when alarm contact is closed. A1Lb Alarm 1 Loop Break. Select On or OFF. On Loop Break Condition will cause an Alarm Condition. OFF Loop Break will not affect the Alarm Condition. LPbr Loop Break Protection: Select OFF, 1 to 9999 seconds. If, during operation, the output is minimum (0%) or maximum (100%), and the input moves less than 5 F (3 C) or 5 counts over the time set for LPbr, the LOOP bad message will appear. This condition can also be routed to an Alarm Condition if alarms are present and turned On (see ALbr in the secure menu). The loop break error can be reset by pressing the ENTER key when at the LPbr menu item. The INDEX & ENTER keys may also be used. SPSA (4-Stage Set Point) Switch Action: Select re or Int. re Set Point Stage selected by external contact closures. Int Set Point Stage selected by internal menu selection. See SP menu item in Secondary Menu. Addr (Serial Communications) Control Address: Set from 1 to 3FF. This number (hexadecimal, base 16) must match the address number used by the host computer. baud (Serial Communications) Communication Baud Rate: Select 300, 1200, 2400, 4800, 9600, or This number must match the baud rate used by the host computer. nat (Serial Communications) No Activity Timer: Set from OFF or 1 to 99 minutes Maximum time between host computer accesses. If timer counts to 0, CHEC/LorE will be displayed. OFF No Activity Timer function is disabled. rscl (Analog Remote Set Point) Remote Scale Low: Select 100 to 9999 counts below rsch. The total span between rscl and rsch must be within counts. Maximum setting range is to counts. rsch (Analog Remote Set Point) Remote Scale High: Select 100 to 9999 counts above rscl. The total span between rscl and rsch must be within counts. Maximum setting range is to counts. OPERATION OF SELF TUNE FUNCTION Self Tune allows automatic selection of the necessary parameters to achieve best control operation from your DSL Series control. If you are using the control output as a simple on-off function (Out1 set for OnOF), none of the following will apply. Revision - Date: 02-02/20/13 25
27 Theory of Operation The Self Tune function calculates the Pb1, res, and rte parameters under the PID tune selection, and the Fbnd and FrtE parameters, as shown in the Secure Menu. These values are determined by measuring the response of the process connected to the control. When Self Tune is started, the control temporarily acts as an on-off control. While in this mode, the control measures the overshoot and undershoot of the process, and the period of the process (the time from peak value to the next peak value). These measurements are collected over three periods of overshoot and undershoot. The data collected over this time is then compared and calculated into final PID and Fuzzy Logic values. The effect of Fuzzy Logic on the process is still controlled by the Fint (fuzzy intensity) setting. If Fint is 0, the Fbnd and FrtE will be calculated, but will have no effect. The calculations for the PID values are the same as used in the standard Ziegler - Nichols equations that have been recognized as standard for decades. The only modification to the application of the Ziegler - Nichols equations is controlled by the dfac menu item. This menu item controls the amount of rate (derivative) that is applied. A dfac setting of 3 (factory default) or less allows for less damping. A dfac setting of 4 allows for critical damping as set forth in Ziegler - Nichols. A dfac setting of 5 or more allows over damping of the process. Fuzzy Logic The term "Fuzzy Logic" as used in this control describes a set of control algorithms which alter the output variables. They can be said to be a "smart" data manipulator. When properly applied, fuzzy logic can increase the heatup response by virtue of the fuzzy band width (Fbnd), and improve system recovery after an upset by virtue of the fuzzy rate of change (FrtE). This is particularly useful in high energy electric heating or anywhere that rapid process variables are present. Since Fuzzy Logic modifies these output variables, we can increase or decrease this effect through adjustment of the fuzzy logic intensity (Fint). Review the setting information found on page 17 of this manual. Program Setup and Operation In the secondary menu, set tune to SELF. Skip LErn and check to make sure that dfac is set to the desired value. Back up to LErn and set to YES. The control will begin the Self Tune function. While the Self Tune function is active, the right hand decimal point on the lower display will blink. When Self Tune is complete, the blinking will stop. After Self Tune is complete, the tune setting automatically switches to PID. This allows examination and/or modification of the values calculated. We recommend that you do not change the calculated values unless you have a firm understanding of the parameters involved and their function. For more information on PID tuning, please contact Process Technology Technical Sales personnel. Revision - Date: 02-02/20/13 26
28 SPECIFICATIONS Selectable Inputs: Thermocouple, RTD, DC Voltage, or DC Current selectable. Input Impedance: Thermocouple = 3 megohms minimum. RTD current = 200 ua. Current = 10 ohms. Voltage = 5000 ohms. Sensor Break Protection: De-energizes control output to protect system after customer set time. (See InPt in Secondary Menu.) Set Point Range: Selectable (See Range Chart Page 22). Display: Two 4 digit, 7 segment 0.3" high LEDs. Control Action: Reverse (usually heating), Direct (usually cooling) selectable. Proportional Band: 1 to 9999 F, C, or counts. Reset Time (Integral): Off or 0.1 to 99.9 minutes. Rate Time (Derivative): Off or 0.01 to minutes. Cycle Rate: 1 to 80 seconds. On - Off Differential: Adjustable 1 F, 1 C, or 1 count to full scale in 1 F, 1 C, or 1 count steps. Alarm On - Off Differential: 1 F, 1 C, or 1 count. Fuzzy Percent: 0 to 100%. Fuzzy Rate: Off or 0.01 to minutes. Fuzzy Band: Off or 1 to 4000 F, C, or counts. Accuracy: ±0.25% of span, ±1 least significant digit. Resolution: 1 degree or 0.1 degree, selectable. Line Voltage Stability: ±0.05% over the supply voltage range. Temperature Stability: 4μV/ C (2.3 μv/ F) typical, 8 μv/ C (4.5 μv F) maximum (100 ppm / C typical, 200 ppm / C maximum). Common Mode Rejection: 140 db minimum at 60 Hz. Normal Mode Rejection: 65 db typical, 60 db at 60 Hz. Isolation: Relay and SSR outputs: 1500 VAC to all other inputs and outputs. SP1 and SP2 Current outputs: 500 VAC to all other inputs and outputs, but not isolated from each other. SP1 and SP2 Switched Voltage outputs: 500 VAC to all other inputs and outputs, but not isolated from each other. Process Output: 500 VAC to all other inputs and outputs. Supply Voltage: 100 to 240 VAC, nominal., %, 50 to 400 Hz. single phase; 132 to 240 VDC, nominal., %. Power Consumption: 5VA maximum. Operating Temperature: -10 to +55 C (+14 to 131 F). Storage Temperature: -40 to +80 C (-40 to 176 F). Humidity Conditions: 0 to 90% up to 40 C non-condensing 10 to 50% at 55 C non-condensing. Memory Backup: Nonvolatile memory. No batteries required. Revision - Date: 02-02/20/13 27
29 Control Output Ratings: SSR: 2.0 A combined outputs A & 240 VAC at 25 C (77 F). Derates to C (130 F). Relay: SPST, VAC resistive; VAC inductive; Pilot duty rating 240 VA, VAC or 1 A 240 VAC. Alarm Relay: SPST, VAC resistive. Current (isolated): 0 to 20 ma across 600 ohms maximum. Switched Voltage (isolated): ma. Panel Cutout: 45 mm x 45 mm (1.775" x 1.775"). Depth Behind Mounting Surface: mm (4.54"). Weight: 220 g (8 oz). Agency Approvals: culus, CE. Front Panel Rating: Type 2, 3R, 3S, 4, 4X, 12, for indoor use only (IP66). THERMOCOUPLE TYPES INPUT RANGES (Field Selectable) Input Type J or L* Type K* Type T* Type E* Type Iron Chromel Copper Chromel Constantan Alumel Constantan Constantan Range -100 to F -200 to F -350 to +750 F -100 to F -73 to +871 C -129 to C -212 to +398 C -73 to +982 C Input Type R Type S Type B Type C Type PT 13% PT 10% PT 6% RE W 5% RE PT PT PT 30% RE W 26% RE Range 0 to 3200 F 0 to 3200 F +75 to 3308 F 0 to 4208 F -17 to C -17 to C +24 to 1820 C -17 to 2320 C Input Type N* Type Ni Chr Si - Ni Si * These Input Types can be set for 0.1 display. If temperature goes above or less than Range -100 to F the display will return to whole degree resolution. -73 to C RTD TYPES Input 100 Ohm 100 Ohm 120 Ohm 1000 Ohm Type Platinum Platinum Nickel Platinum DIN Nist US Nist Curve* Curve* Ind. Curve* Curve* Range -328 to F -328 to F -112 to +608 F -328 to F -200 to +875 C -200 to +875 C -80 to +320 C -200 to +875 C Process Input Types The 0 to 20 madc, 4 to 20 madc, 0 to 10 VDC, 2 to 10 VDC, and -10 to +10 mvdc inputs are fully scalable from a minimum of 100 count span placed anywhere within the range of to Decimal point position is adjustable from the zero place (9999), tenths (999.9), hundredths (99.99), thousandths (9.999), or ten thousandths (.9999). Revision - Date: 02-02/20/13 28
30 DIAGRAM 10 Revision - Date: 02-02/20/13 29
Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C
F4 Process Controller Installation and Operation Guide SAFETY ALERTS The symbols below are used on the equipment and throughout this document to draw the user s attention to important operational and safety
Auto-tune PID. Temperature Controller BRAINCHILD FEATURES
Auto-tune PID Temperature Controller FEATURES Easy-to-use Fuzzy modified PID heat & cool control Fast A-D sampling rate (5 times/s) Universal input (PT100, thermocouple) with high accuracy 18-bit A-D Analog
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
PID Microprocessor temperature controllers CTD43 - CTD46 - CTH46
PID Microprocessor temperature controllers CTD43 - CTD46 - CTH46 Display 1. Red measurement display (or the set point for CTD 43 by pressing, indicated by a flashing decimal point). 2. Green display of
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.
Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line
BT. 2.9 M/E Process controller programmer /6 DIN - 48 x 48 mm gammadue series M line Advanced features, customizable and process adaptable High speed data aquisition and signal management. Efficent information
TC-9102 Series Surface Mount Temperature Controllers
TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may
SYL-2372 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.4 (May 2016)
AUBER INSTRUMENTS Instruction Manual SYL-7 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.4 (May 16) Caution This controller is intended to control equipment under normal operating conditions.
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
+ A + + - B V B - - + + + NO NC V COM - - - PV PV
+ - A + B B - V + - NO NC COM + - + - V + - PV PV Ramp Soak 100 70 50 30 3 5 3 8 5 3 Minute Steam Heating Sensor Cooling Water PID Hotplate Specifications Input power supply AC 100 to 240V, 50/60Hz, DC
MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE
DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000
Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual
Ⅰ. Warn Warning of connection Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual If the controller fails to operate or error occurs, the system will bring fault for it, please
2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:
COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER KT4, KT8 and KT9 No.KTC1E6 2009.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.
User Manual Auto Tuning PID Temperature Controller
User Manual Auto Tuning PID Temperature Controller TUPC-T series (Applicable for accurate controls of Temperature) TEMPSEN DEVICES Plot No : 2&3, Balaji Nagar, 4 th Street, Mettukuppam, Thoraipakkam, Chennai-600097
Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) 876-4444 Tel: (203) 426-7700 Fax: (203) 426-7800 www.walkeremd.
Eclipse Series Digital Panel Meters Installation and Operation Manual Number 57700-900-05 Models: 5770X-40X - DC Volts 5770X-4X - AC Volts 5770X-42X - DC Amps 5770X-43X - AC Amps 5770X-44X - 5A AC 5770X-45X
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
Electronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015
Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) The standard tuning values used in ADVANCED Motion Controls drives are conservative and work well in over 90%
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
HONEYWELL DC 1010 / 1020 1030 / 1040 DIGITAL CONTROLLER PRODUCT MANUAL 51-52-25-113 06/02
HONEYWELL DC 1010 / 1020 1030 / 1040 DIGITAL CONTROLLER PRODUCT MANUAL 51-52-25-113 06/02 Before using this manual, please check to ensure the Model number, input type Range and output match your requirements.
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
How to read this guide
How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information
PPM Users Manual Signature Software 01-12-00
PPM Users Manual Signature Software 0-2-00 PPM User Manual /8/02 Software Versions: 0.0.27 Contents. Introduction 2 2. Parameters 3 2. Overload Limit...4 2.2 Relative Upper Limit...4 2.3 Relative Lower
Programmer/Controller
Systems Plus START 7 8 9 envirotronics ALARM STOP 4 5 6 ALARM ACK Instrument Manual Systems Plus Programmer/Controller OFF HELP 1 2 0 3. ENTER ALARM RESET DEL Revision 6 9/12/97 Table of Contents 2 Menu
S4000TH HART. HART Communication Manual
HART Communication Manual The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by General
Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]
Bulletin P-DM-1100 Series DM-1000 DigiMag Digital Differential Pressure Gage Specifications - Installation and Operating Instructions PRESSURE CONNECTIONS 21/64 [8.59] LONG Ø5 [127.00] 4-31/64 [113.89]
Preliminary. Dual-line FLOW rate/totalizers. Pr ovu Model PD6200 Analog Input. Pr ovu Model PD6300 Pulse Input. Analog Inputs.
Dual-line FLOW rate/totalizers Pr ovu PD6200 Analog Input ProVu Se r i e s Pr ovu PD6300 Pulse Input Analog Inputs 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs Isolated 24 VDC @ 200 ma Transmitter
TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM
TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give
Nokeval. User's Manual Models 301 / 302 / 305
Nokeval User's Manual Models 301 / 302 / 305 No 16042010 1 Contents Contents... 2 General description... 3 Disabling front panel keys... 4 Front panel buttons and indicators... 5 Configuration mode...
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
O C M III. Open Channel Flow Monitor
O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this
THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012
Technical Information THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 GENERAL DESCRIPTION THYRISTORS T1-1PH is a full digital and universal
CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13
CONTENTS PAGE Chapter 1 General Information 1 Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13 Chapter 3 Alarm/Excitation Options 15 Wiring 17 Chapter
MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
Ground Resistance Clamp On Tester
USER MANUAL Ground Resistance Clamp On Tester MODEL 382357 Introduction Congratulations on your purchase of Extech s 382357 Ground Resistance Tester. This Clamp on device allows the user to measure ground
MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
User Manual. Humidity-Temperature Chart Recorder. Model RH520
User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,
MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card
Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully
920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown
Self-Regulating 920 Series Dual-point heat-tracing control system Power-Limiting Mineral Insulated 920*E4FWL*SIS302*SS3102 shown Product overview The DigiTrace 920 is a compact, full-featured, microprocessor-based,
Dyeing Programmer DP - 01
Dyeing Programmer DP - 01 Display and Controls. 1) Display: 16/2 alphanumeric display 2) Temperature range: 0 to 150 degree. 3) Resolution: 1 degree. 4) Accuracy: +/- 1 degree. 5) Temperature control setting:
DPI 260 SERIES: Digital Pressure Indicators
DPI 260 SERIES: Digital Pressure Indicators INTRODUCTION The DPI 260, 261 and 262 range of digital pressure instruments measure and indicate pressure in any specified scale units and provide accuracies
Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual
Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com [email protected] TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION
Controller Automation, Model II+
Controller Automation Page 2 of 2 Automation with the RADAK II+ power controller II+ I/O Points: Inputs 5 Programmable Digital inputs 2 Dedicated digital inputs (Channel select and External SCR control
J TB/TW Temperature limiter, temperature monitor
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: [email protected] Internet: www.jumo.net
AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002
AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002 First Edition MONITORING AND LABORATORY DIVISION August
BACnet Automation Interface Module (Network Version)
Sense +V Tx Rx LAN LINK Over ARCNET KBaud BACnet Rx BACnet Tx Archive Valid Port S Tx Port S Rx Low Battery Network- Enhanced Access Default MSTP PTP = Download Required on Rnet and Port S IP Address IP
NOW A PRODUCT! 1 /4 DIN PROCESS CONTROLLER. Single Loop Profile Controller (optional) NEMA 4X Front Panel PowerTune. The Interface Solution Experts
NOW A 5 3 5 The Interface Solution Experts PRODUCT! 5 3 5 1 /4 DIN PROCESS CONTROLLER Single Loop Profile Controller (optional) NEMA 4X Front Panel PowerTune The Interface Solution Experts www.miinet.com
Model 5511 Filler Controller User s Manual Version 1.1 October 2011
Thompson Scale Company WEIGHING SYSTEMS & PACKAGING MACHINERY CONTROLS 2758 Bingle Road Houston, Texas 77055 Phone: 713/932-9071 Fax: 713/932-9379 www.thompsonscale.com Model 5511 Filler Controller User
TC 1818a. Operating Guide. Control Module SWM-015.5
TC 1818a Control Module Operating Guide SWM-015.5 This guide is intended solely for use by owners of Thermon HeatChek TM heat tracing control and monitoring units. This manual describes operation for TC
4-Channel Thermometer / Datalogger
USER GUIDE 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This meter
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2
COMMERCIAL INSTALL GUIDE 2 Contents How to Use This Guide: The first section of this guide is designed to assist you with the installation of your DECK Monitoring hardware. The revenue grade meter and
Temperature Transmitter TTX300
coo Interface Description COM/TTX300/FF-EN Temperature Transmitter TTX300 FOUNDATION Fieldbus Contents Blinder Text Temperature Transmitter TTX300 Interface Description COM/TTX300/FF-EN 01.2010 Manufacturer:
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,
Multifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
T-100-R Installation Guide
T-100-R Installation Guide Table of Contents Page 2 Overview T-100-R Z-Wave Thermostat 3-4 Installation HVAC System Setup 6 Installer Settings Menu Items 7-9 Installer Settings Summary 10-11 Wiring Standard
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
Installation Instructions For Controllers with MS/TP Automatic MAC Addressing. Patent Pending 000-019-01
Installation Instructions For Controllers with MS/TP Automatic MAC Addressing Patent Pending 000-019-01 KMC Controls Important notices Disclaimer 2009, KMC Controls, Inc. TotalControl, BACstage and FullBAC
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
Analog Servo Drive 25A8
Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit
PRODUCT PROFILE FEATURES
PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER
THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Troubleshooting and Diagnostics
Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem
APPLICATION NOTE. Measuring Current Output Transducers with Campbell Scientific Dataloggers. App. Note Code: 2MI-B Revision: 1
App. Note Code: 2MI-B Revision: 1 APPLICATION NOTE Measuring Current Output s with Campbell Scientific Dataloggers 815 W. 1800 N. Logan, Utah 84321-1784 (435) 753-2342 FAX (435) 750-9540 Copyright (C)
TIMING, COUNTING, AND DATA-HANDLING INSTRUCTIONS. Key Points
M O D U L E F O U R TIMING, 4 COUNTING, AND DATA-HANDLING INSTRUCTIONS Key Points This module is a further exploration of the MicroLogix s programming instructions. Module 3 covered basic relay instructions,
Operator s Manual Revision III 03/31/99
A.P.E. Wide Area Radiant Surface (WAR S) Hot Plate Station Operator s Manual Revision III 03/31/99 Contents: 1.1. Introduction 1.2. Construction 1.3. Unpacking & Assembly 1.4. Power Up 1.5. Getting Started
The E5CN provides communications or event input functionality when mounted with one of the following Option Boards.
Digital Temperature Controller Compact and Intelligent Temperature Controller Auto-tuning and self-tuning available. Can auto-tune even during execution of self-tuning Heating or heating/cooling control
Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN
Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
DLP-PU/E Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
SX460. Generator Automatic Voltage Regulator Operation Manual
SX460 Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible with Newage SX460* * Use for reference purpose only and not a genuine Newage product. 1.
GREISINGER electronic GmbH
T38.0.0X.6C-03 CO2 - Transmitter Operating Manual GT10 - CO2-1R GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 Tel.: +49 9402 / 9383-0, Fax: +49 9402 / 9383-33, email: [email protected]
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
CPW Current Programmed Winder. Application Handbook. Copyright 2002 by Eurotherm Drives, Inc.
CPW Current Programmed Winder Application Handbook Copyright 2002 by Eurotherm Drives, Inc. All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted, in
HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function
Specifications Supply Voltage 240VAC @ 0.07Amps or 24VAC @ 0.380Amps Relays 240V @ 12A max (resistive) / Comp1,2,3, Aux Ht, Rv O/B) Fuses (Equipment) 15 Amps Maximum 3AG Control Range Minus 10 to 50C Control
BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault
Sierra S-Series Smart Interface Software User Manual
Sierra S-Series Smart Interface Software User Manual Part Number IM-SIP 08/99 Revision B 5 Harris Court, Building L Monterey, CA 93940 (831) 373-0200 (800) 866-0200 Fax (831) 373-4402 http://www.sierrainstruments.com
MODEL 1211 CURRENT PREAMPLEFIER
MODEL 1211 CURRENT PREAMPLEFIER Phone: (607)539-1108 Email: [email protected] www.dlinstruments.com The Model 1211 Current Preamplifier was designed to provide all of the features required of a modern
Mode Switch. Fan Switch Menu button Program button
Operation 3M-30 Day Time of day Target Temperature Time Slot Touch Screen Current Room Temperature Thermostat Mode Statement of use: The 3M-30 can be used with millivolt, 24VAC, single and 2 stage conventional
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
DWYER INSTRUMENTS, INC. Phone: 219/879-8000 P.O. BOX 373 MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.
Series DCT1000 Dust Collector Timer Controller Specifications Installation and Operating Instructions Bulletin E-97 Thank you for purchasing the DCT1000 Dust Collector Timer Controller. You have selected
