Intel Management Module Installation and User s Guide
|
|
|
- Alexina Walker
- 10 years ago
- Views:
Transcription
1 Intel Management Module Installation and User s Guide Document P/N C
2 Legal Information Intel Corporation This Intel Management Module Installation and User Guide as well as the software described in it is furnished under license and may only be used or copied in accordance with the terms of the license. The information in this manual is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by Intel Corporation. Intel Corporation assumes no responsibility or liability for any errors or inaccuracies that may appear in this document or any software that may be provided in association with this document. Except as permitted by such license, no part of this document may be reproduced, stored in a retrieval system, or transmitted in any form or by any means without the express written consent of Intel Corporation. INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. The Intel Server Board SE7520AF2, Intel Server Board SE7520BD2, Intel Server Board SE7520JR2, Intel Management Module Professional Edition, and Intel Management Module Advanced Edition may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. Intel, Pentium, Itanium, and Celeron are registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. * Other names and brands may be claimed as the property of others. Copyright 2004, 2005 Intel Corporation. All rights reserved. 2 Intel Management Module Installation and User s Guide
3 Contents Introduction 5 Intel Management Module Features... 5 Getting the Latest Information and Support... 6 Platform Compatibility and System Requirements... 6 Installation Procedures 8 Before You Begin... 8 Location of Intel Management Module Header... 8 Installing the Intel Management Module Professional Edition Removing the Intel Management Module Professional Edition Installing the Intel Management Module Advanced Edition Removing the Intel Management Module Advanced Edition Intel Advanced Remote Server Control 17 Alerting 18 Embedded SNMP 19 Configuring SNMP...19 Using the BMC-Resident SNMP Agent Embedded CLI (Telnet) 21 Configuring the Embedded CLI (Telnet) Feature Using the Embedded CLI (Telnet) Feature Embedded Web Server 22 Configuring the Embedded Web Server Using the Embedded Web Server Appendix A: Command Line Interface Syntax 26 References 31 Glossary 32 Intel Management Module Installation and User s Guide 3
4 4 Intel Management Module Installation and User s Guide
5 Introduction The Intel Management Module is an upgrade to the National Semiconductor PC87431 mini-bmc management controller on the Intel Server Board SE7520AF2, Intel Server Board SE7520BD2, Intel Server Board SE7520JR2, and Intel Server Board SE8500HW4. The Intel Management Module plugs into a connector on the server board. The Intel Management Module is available in two versions: Professional Edition Advanced Edition Intel Management Module Features Professional Edition Features The Professional Edition includes the following features: All the features provided by the mbmc Support for IPMI v2.0 specification Additional sensors Temperature-based fan speed control by the BMC Additional FRU records are visible to the management controller and management software applications (for example, Power Supply, DIMM, and hot-swap controller FRU s). The size of the System Event Log (SEL) is increased from 92 entries to 3276 entries The number of BMC users is increased from one anonymous user to four users (each with configurable user names and passwords on each LAN or Serial channel) The IPMI 2.0 serial features are supported. The serial port can be used for console redirection, Terminal-mode CLI, dial paging, Serial Over LAN (SOL), and other management functions. The Intelligent Chassis Management Bus (ICMB) is supported PCI SMBus is accessible to the management controller. This allows PCI add-in cards that support manageability to log events to the System Event Log (SEL). BIOS logging of POST progress codes is added to the existing capability of logging only the BIOS POST errors Front panel functionality is enhanced (See: Secure Mode Button Actions in the platform Technical Product Specification) For systems with the SATA or SCSI hot-swap controller (HSC), the HSC sensors are visible to server management software and HSC events are logged in the SEL. Intel Management Module Installation and User s Guide 5
6 Advanced Edition Features The Advanced Edition adds all the features listed above for the Professional Edition, plus the following features: BMC-resident SNMP support for out-of-band access using 3 rd party applications such as Hewlett-Packard* OpenView* Embedded web server to access system health, view the SEL, and issue IPMI commands Embedded Command Line Interface (using a Telnet server running on the BMC) to allow direct terminal access to the BMC Alerting via Intel Advanced Remote Server Control adds remote KVM functionality High-speed access to a dedicated NIC for the BMC on the Advanced Edition module The Intel Advanced Remote Server Control, alerting, embedded CLI, embedded web, BMC-resident SNMP agent, SOL, and other firmware-resident features are available Out-of-Band (OOB). This means that these features are available even when the Operating System is not running or the AC power is off. Getting the Latest Information and Support The latest information on each server board and Intel software is available at: Platform Compatibility and System Requirements The Intel Management Modules are compatible with the following Intel server boards: Intel Server Board SE7520AF2 Intel Server Board SE7520BD2 Intel Server Board SE7520JR2 Intel Server Board SE8500HW4 Table 1 on page 7 lists the minimum system requirements. 6 Intel Management Module Installation and User s Guide
7 Table 1. Minimum System Requirements To use this feature Intel Advanced Remote Server Control Embedded Web Server Embedded CLI (Telnet Server) Alerting Serial Over LAN You will need ISM 8.20 Intel Advanced Remote Server Control component installed on the Administration Console Intel Management Module Advanced Edition installed on the managed server Intel Management Module Advanced Edition installed on the managed server Intel Management Module Advanced Edition installed on the managed server Intel Management Module Advanced Edition installed on the managed server Intel Management Module Advanced Edition or Professional Edition installed on the managed server Intel Management Module Installation and User s Guide 7
8 Installation Procedures Before You Begin Read the Warnings and Safety Cautions section in the user s guide for your server baseboard. Location of Intel Management Module Header The following illustrations show the location of the Intel Management Module header on the Intel Server Board SE7520AF2, Intel Server Board SE7520BD2, Intel Server Board SE7520JR2, and Intel Server Board SE8500HW4. Figure 1. Location of Intel Management Module Connector on the Intel Server Board SE7520AF2 8 Intel Management Module Installation and User s Guide
9 Figure 2. Location of Intel Management Module Connector on the Intel Server Board SE7520BD2 Figure 3. Location of Intel Management Module Connector on the Intel Server Board SE7520JR2 Intel Management Module Installation and User s Guide 9
10 Module Header Figure 4. Location of Intel Management Module Connector on the Intel Server Board SE8500HW4 10 Intel Management Module Installation and User s Guide
11 Installing the Intel Management Module Professional Edition The Professional Edition consists of the following components: 1 nylon standoff Intel Management Module Professional Edition. The following illustration shows the location of the standoff and retraction strap on the Professional Edition module (the location is the same on the Advanced Edition module). The upper illustration shows the bottom of the module. The lower illustration shows the top of the module. KEY: A.) Location of the extraction strap B.) Location of the nylon standoff C.) Location of the module connector to the server board B. C. A. A. B. Figure 5. Location of the Connector, Extraction Strap, and Standoff on the Intel Management Module (Professional Edition) Intel Management Module Installation and User s Guide 11
12 To prepare for the installation, you will need the following: The utilities for your server board (available on the Intel Server Deployment Toolkit CD shipped with your server board) The latest FRU/SDR package, firmware update files, and Release Notes from To install the Professional Edition module, do the following: 1. Power down the system. 2. Remove AC power. 3. Open the chassis to gain access to the Intel Management Module Connector. 4. Insert the nylon standoff into the baseboard to support the Intel Management Module. Choose the hole farthest away from the strap after the Intel Management Module is inserted into the connector. 5. Align the Management Module over the baseboard connector and the nylon standoff. 6. Press down on the Management Module to fully seat the connector and standoff. 7. Close the chassis, reconnect the AC power, and power-on the system. 8. Update the firmware and FRU/SDR for your server board. Use the latest files and instructions for your server board that you downloaded from 9. Install ISM 8.20 from the ISM 8 Installation CD, or run the Intel Server Configuration Wizard (SCW) from the Intel Server Deployment Toolkit CD to configure the new features on the Professional Edition module. Removing the Intel Management Module Professional Edition To remove the Professional Edition module, do the following: 1. Power down the system. 2. Remove AC power. 3. Open the chassis to gain access to the Intel Management module. 4. Pinch the end of the standoff and slightly raise the Management Module to disengage the standoff. To avoid damage to the connector, do not lift the edge the board that is farthest from the connector (near the standoff). 5. Using the strap attached to the module, gently pull up to slightly disengage the end of the connector closest to the strap. Using your fingers, grasp the board near the other end of the connector and gently rock the board back and forth until the connector is completely disengaged. 6. Close the chassis and reconnect the AC power. 12 Intel Management Module Installation and User s Guide
13 Installing the Intel Management Module Advanced Edition The Advanced Edition Module consists of the following components: 1 Nylon Standoff Intel Management Module Advanced Edition The following illustration shows the location of the standoff, connector, and retraction strap on the Advanced Edition module. KEY: A.) Location of the extraction strap B.) Location of the nylon standoff C.) Location of the module connector to the server board A. C. B. Figure 6. Location of the Connector, Extraction Strap, and Standoff on the Intel Management Module (Advanced Edition) Intel Management Module Installation and User s Guide 13
14 NOTE This NIC card and associated hardware listed below are not used with the SE8500HW4 server board, which has a dedicated system management NIC on the server baseboard. Intel Management Module Network Interface Card. 2 Screws Rear filler panel with LAN connection knockout (not required for SR1400 and SR2400 chassis) The following illustration shows the network interface card, filler panel, and screws. Figure 7. Intel Management Module Network Interface Card, Rear Filler Panel, and Screws 2 I2C Cables (one long and one short cable) To prepare for the installation, you will need the following: The utilities for your server board (available on the Intel Server Deployment Toolkit CD shipped with your server board) The latest FRU/SDR, firmware update files, and Release Notes (download from ) A Medium Phillips screwdriver to attach the NIC card to the rear filler panel 14 Intel Management Module Installation and User s Guide
15 To install the Advanced Edition module, do the following: 1. Power down the system. 2. Remove AC power. 3. Open the chassis to gain access to the Intel Management Module Connector and the rear panel. 4. For Intel Server Chassis SR1400 or Intel Server Chassis SR2400 with Intel Server Board SE7520JR2: follow the instructions in the chassis Product Guide to remove the Add-in Card Riser. Insert one nylon standoff in the baseboard to support the Management Module. 5. If you are installing in a SE8500HW4 platform, skip this step. Connect the cable between the Management Module and the NIC card. If you are installing the NIC in the SR1400 or SR2400 chassis, use the short cable, otherwise use the longer cable. 6. Align the Management Module over the baseboard connector and the nylon standoff. 7. Press down on the Management Module to fully seat the connector and standoff. 8. For Intel Server Chassis SR1400 or Intel Server Chassis SR2400 with Intel Server Board SE7520JR2, install the NIC on the rear panel using 2 screws. The following illustration shows the location of the network connector (NIC3) on the rear panel of the Intel Server Chassis SR1400. NIC3 Replace the Add-in Card Riser. 9. For all other chassis types, except SE8500HW4 platforms: a. Connect the NIC to the filler panel with two screws. b. Install the NIC and filler panel in a full-height PCI rear panel slot. 10. Connect the LAN cable to the NIC. 11. Close the chassis, reconnect the AC power, and power-on the system. 12. Update the firmware and FRU/SDR for your server board. Use the latest files and instructions for your server board that you downloaded from For headless operation (no keyboard), enter BIOS Setup (press F2 during POST) and change the POST Error Pause option to disable. 14. Run the Intel Server Configuration Wizard (SCW) from the Intel Server Deployment Toolkit CD to configure the new features on the Advanced Edition module. NOTE To ensure that the NIC on the Advanced Edition module is properly configured, answer No to the following SCW question: Intel Server Manager Application software and/or agents will be installed on this server. Intel Management Module Installation and User s Guide 15
16 NOTE If you want to use Intel Advanced Remote Server Control (the ISM remote keyboard, video, and mouse software) with this IMM, when you run SCW, specify a static IP address for the NIC on the Advanced Edition module. 15. Run the ISM 8 Installation CD to install the Embedded SNMP MIB file and Intel Remote Server Control client viewer application. Removing the Intel Management Module Advanced Edition To Remove the Advanced Edition module, do the following: 1. Power down the system. 2. Remove AC power. 3. Open the chassis to gain access to the Intel Management Module. 4. Disconnect the cable to the NIC. 5. Pinch the end of the standoff and slightly raise the Management Module to disengage the standoff. 6. Using the strap attached to the module, gently pull up to disengage the connector. Using your fingers, lift up the other end of the connector and gently rock the connector back and forth until the connector is completely disengaged. To avoid damage to the connector, do not lift the edge the board that is farthest from the connector. 7. Close-up the chassis and reconnect the AC power. 16 Intel Management Module Installation and User s Guide
17 Intel Advanced Remote Server Control The Intel Advanced Remote Server Control feature provides Keyboard, Video, Mouse (KVM) redirection over the network to a remote client running the Intel Advanced Remote Server Control viewer application. Run the Intel Server Configuration Wizard (SCW) on the Intel Server Deployment Toolkit CD to enable the KVM feature. To use Intel Advanced Remote Server Control with the Advance Edition module, when you run SCW, specify a static IP address for the NIC on the IMM. The client-side utility for using this feature is launched either from the Intel Server Manager (ISM) 8.20 console or from a web browser. Use the ISM 8 Installation CD to install this component of ISM Intel Management Module Installation and User s Guide 17
18 Alerting Simple Mail Transport Protocol (SMTP) is a host-to-host protocol over TCP. SMTP alerting allows you to send simple alerts to preconfigured destinations. Use the Intel Server Configuration Wizard to configure the alerting feature. You can configure the following parameters: Number of supported alert configurations From, To, and Subject lines Alerting machine name The body of the alert message consists of the System Event Log (SEL) entry (English only) for the event that caused the alert. NOTE alerting is only available on the network attached to the Advanced Edition module NIC. 18 Intel Management Module Installation and User s Guide
19 Embedded SNMP You can connect to the managed server and use either an OS-resident SNMP agent or the Embedded (BMC-resident) SNMP agent. Table 2 summarizes the features available in the two SNMP access methods. Table 2. Features Available with BMC and OS Agents Feature BMC SNMP Agent OS SNMP Agent Access Sensor Data Yes Yes View threshold settings Yes Yes Modify threshold settings No Yes (Voltage, Temperature, System Fan) Read the SMBIOS tables No Yes Provide overall system health status No Yes SET Yes (Limited) Yes SNMP access without OS running on Yes No Managed Server Uses dedicated NIC Yes No Configuring SNMP For instructions on installing and using the OS-specific SNMP Subagents, refer to the Installing and Configuring the Intel Server Manager 8 SNMP Subagents document (SNMP_Subagent_Install_and_Config_Guide.pdf) on the ISM 8 Installation CD. To use the BMC-resident SNMP agent, install the BMC.MIB file using the ISM 8 SNMP installation option. Run the Server Configuration Wizard (SCW) on the Intel Server Deployment Toolkit CD to configure the BMC SNMP Agent. The SCW will allow the user to configure the following: Enable SNMP Configure the SNMP port number for Get/Set commands Configure LAN alerting for SNMP Traps Set the SNMP Trap destination Using the BMC-Resident SNMP Agent To use the BMC-resident SNMP Agent, do the following: 1. Connect the NIC on the Advanced Edition module to the network. 2. Launch your SNMP-aware network management station (for example, Hewlett-Packard s OpenView) on a remote administrative system. Intel Management Module Installation and User s Guide 19
20 3. Copy the BMC.MIB file from the Intel Server Deployment Toolkit CD to your local hard drive. Load this MIB into your NMS application. 4. Set the SNMP community string to public to read the sensor data, or private to use the SNMP SET commands. The user has two SNMP SET commands available when using the BMC-resident SNMP agent: Set the SNMP-only machine name variable to help confirm which managed server is being addressed by a particular SNMP request. Set Chassis ID LED to turn on/off the front panel ID LED. 20 Intel Management Module Installation and User s Guide
21 Embedded CLI (Telnet) Configuring the Embedded CLI (Telnet) Feature Run the Server Configuration Wizard (SCW) on the Intel Server Deployment Toolkit CD to configure the Embedded CLI Telnet Server. The SCW allows you to: Enable the Telnet Server in firmware Configure the Telnet port number Using the Embedded CLI (Telnet) Feature The firmware on the Advanced Edition module includes a telnet server. The telnet server provides you with both in-band and out-of-band monitoring and control of the server by using Intel s proprietary Command Line Interface (CLI) syntax called Common CLI (CCLI). The telnet server also allows you to establish a Serial Over LAN (SOL) session. To use the embedded CLI feature, do the following: 1. Connect to the Telnet server. For example, to Telnet to a server at IP address from the command prompt, type the following: Telnet Log-in to the server. The Telnet server will ask for the BMC user name and password for LAN channel 3 (this is the NIC attached to the Advanced Edition module). (Use the SCW to configure the user names and passwords.) The server responds with the CLI prompt: CLI> 3. Type a CLI command (the CLI syntax is listed in Appendix A on page 26). For example: CLI>health The server return codes and responses are listed in Appendix A on page 26. NOTE The CLI syntax for the embedded Telnet server is slightly different than the syntax defined in the IPMI 1.5 specification for terminal mode CLI. Intel Management Module Installation and User s Guide 21
22 Embedded Web Server Configuring the Embedded Web Server Run the Intel Server Configuration Wizard (SCW) from the Intel Server Deployment Toolkit CD to configure the Embedded Web Server. The SCW allows you to: Enable the web server in firmware Configure the HTTP Port number Using the Embedded Web Server Introduction The Embedded Web Server has six firmware-resident web pages: System Summary Page displays the overall system health and health indicators for individual sensors System Event Log displays selected number of records from the System Event Log Power provides power and reset controls IPMI Command accepts IPMI hex commands or Native CLI commands and returns a response Configuration provides configuration controls for the Embedded Web Server Help provides on-line help Each page has navigation links on the left side for quick navigation to another page plus an overall health indicator (directly above the navigation links). 22 Intel Management Module Installation and User s Guide
23 The following figure shows the System Summary Page. Using the Web Page Interface Figure 8. System Summary Page for the Embedded Web Server To access the Embedded Web Server, do the following: 1. Go to the following URL: [:portnumber] where hostname is the IP address or domain name for the server. If you have configured the port number to be some number other than port 80, add the port number to the URL. If you encounter problems connecting to the server, try disabling automatic configuration of the browser LAN settings. 2. The Embedded Web Server will prompt you for the BMC user name and password the first time you connect to the server. To log-in as the anonymous user with a Null password, simply leave the user name and password text boxes blank and press Enter. NOTE The Embedded Web Server checks the privilege level of the user before executing every command. The Embedded Web Server will prompt you again if you have logged in with insufficient privilege level to execute the requested command. 3. The Embedded Web Server will display the System Summary page after the user is authenticated. Intel Management Module Installation and User s Guide 23
24 Using the Embedded Web Server Scripting Interface The Embedded Web Server can be accessed from a scripting language such as Perl or JavaScript. The client script sends a GET or POST request to the server. The server returns either an HTML web page or an XML response. To return an HTML Page, use one of the following formats: where xx.xx.xx.xx.xx is an IPMI 2.0 command in hexadecimal that is supported by the platform where subcommand is one of the following: HealthyUpdateRate=num WarningUpdateRate=num CriticalUpdateRate=num UsrUrl1=url (on-line help page URL) UsrVal1=string (navigation bar label, the default is help ) UsrUrl2=url (the default is support.intel.com) UsrVal2=string (navigation bar label, the default is intel.com ) 3:Hostname=string (this only changes an internal web page variable) 3:Domainname=string (this only changes an internal web page variable) The following syntax returns an XML response (see Table 3): where xx represents one byte (two hex digits) of the IMPI 2.0 command (separate each pair of hex digits with a period) Table 3. Web Server Responses Command ipmipage webcmdpage ipmihex Response Argument 1 = completion code Argument 2 = the command that was executed Argument 3 = the command response Argument 1=an error code of 0 or 1 indicates no error Argument 2=an error string associated with the code Argument 3= the response data <ipmiresp completioncode= YY >XX-XX-XX </ipmiresp> (The completion code YY and the returned data bytes XX are defined in the IPMI specification.) 24 Intel Management Module Installation and User s Guide
25 HTML Example. In this example, the client-side page loads the page returned by the Embedded Web Server into a frame. <FRAMESET ><FRAME > <A HREF= IPMI Command to check if web is enabled</a></frame> </FRAMESET> Perl Script Example. In the following example, a Perl script sends an HTTP GET to the server. Use IO::Socket; $sock = new IO::Socket::INET (PeerAddr => , PeerPort => 80, Proto => tcp die Socket could not be created. Unless $sock; print $sock GET /ipmihex?cmd=20.c HTTP/1.0 ); NOTE The default authentication is MD5 Digest authentication. This means that command line scripting tools must be able to handle Authentication failures and respond to the server requests. Intel Management Module Installation and User s Guide 25
26 Appendix A: Command Line Interface Syntax The following Command Line Interface Syntax is used as the default for Terminal Mode CLI, embedded CLI (using the BMC-based Telnet server), and the embedded HTTP server IPMI Command page. Note that this syntax is slightly different than the IPMI 1.5 CLI syntax, or the CLI syntax used with the dpccli proxy (an optional component of ISM 8.20). Table 4 lists the standard return values. Table 5 lists the CLI command syntax. Table 4. Standard Return Values for CLI Commands ok unsupported command unrecognized command command time-out insufficient privilege session in progress Table 5. Command Line Interface Syntax Cmd IPMI Privilege Level Option(s) Short Description Output IPMI Rev: x.x help Display list of valid commands. FW Rev: xx.xx Commands -C <command> Returns a brief description of command Command: xx health User Display the health of the target. PWR:zzz H:xx T:xx V:xx PS:xx C:xx D:xx S:xx O:xx Where: PWR is system POWER state H is overall Health T is Temperature V is Voltage PS is Power Supply subsystem C is cooling subsystem (Fans) D is Hard Drive / RAID Subsystem S is physical Security O is Other (OEM) 26 Intel Management Module Installation and User s Guide
27 Cmd IPMI Privilege Level Option(s) Short Description Output zzz is: "ON", "OFF" (soft-off or mechanical off), "SLP" (sleep - used when can't distinguish sleep level), "S4", "S3", "S2", "S1", "??" (unknown) and xx is: ok, nc, cr, nr, uf, or?? where: "ok" = OK (monitored parameters within normal operating ranges) "nc" = non-critical ('warning': hardware outside normal operating range) "cr" = critical ('fatal': hardware exceeding specified ratings) "nr" = non-recoverable ('potential damage': system hardware in jeopardy or damaged) "uf" = unspecified fault (fault detected, but severity unspecified) "??" = status not available/unknown (typically because system power is OFF) Health :xx -f Display full health status Temperature :xx Voltage :xx id Callback Display the unique identifier for this target (UUID) xxxxxxxx-xxxx-xxxx-xxxxxxxxxxxxxxxx Attempts to reboot the system using OS shutdown by default boot Operator -f Force boot, do not attempt OS shutdown -console During boot, switch to system console output reset Operator -console Initiate a system reset During reset, switch to system console output Intel Management Module Installation and User s Guide 27
28 Cmd IPMI Privilege Level Option(s) Short Description Output shutdown Operator -f Power off by issuing an orderly shutdown to the OS Force OS shutdown. (Switch power off) See Note at the end of the table. -on Switch power on -console Set session to system console for power-on -off Switch power off (no OS shutdown) power Operator -cycle Switch power off, then on (no OS shutdown) -state Display target s current power state ON OFF End current session console (Only Telnet allows this command) Callback Switch the session to system console. ~. switches back to CLI mode. exit (quit) Callback End current session logon (Only Terminal Mode allows this command set) Callback -u <username> -n -p <password> Start a session 28 Intel Management Module Installation and User s Guide
29 Cmd IPMI Privilege Level Option(s) Short Description Output network Operator Displays the current network channel configuration of the BMC. If not LAN channel, it uses the primary NIC channel IP Address: x.x.x.x IP Address Source: (Static DHCP BIOS Other) MAC Address: xx:xx:xx:xx:xx:xx Subnet Mask: x.x.x.x Gateway: x.x.x.x -p <params> Display the requested parameter ( mac ip subnet gateway ). interrupt Operator -console Causes the BMC to generate an IPMI diagnostic interrupt (NMI for IA-32 systems) Switches to console mode and issues the interrupt version Callback Displays the Native CLI version number Native CLI version x.x. Display SEL records. Hex characters for each record, separated by linefeed characters. displaylog User -all All SEL records Ascending or -a -d Descending (default) order - s <first> <last> Displays a set of SEL records clearlog User Clears SEL records identify Operator Activate a local indicator to identify target system (if supported by hardware) Intel Management Module Installation and User s Guide 29
30 Cmd IPMI Privilege Level Option(s) Short Description Output -on [#] Switch indicator on; turn off in # seconds -off Switch indicator off -state Display current state of indicator ON (Application) ON (Button) OFF NOTE Performing a graceful OS shutdown requires that an Intel supplied OS agent be present. If this agent is not present or is unable to/does not respond after 7 seconds, an error message will be displayed for the user and the command will terminate, no reset or power-off will be performed. Graceful shutdown commands will not perform hard resets or power off if OS shutdown does not complete. 30 Intel Management Module Installation and User s Guide
31 References Intel Server Board SE7520BD2 Technical Product Specification (available on support.intel.com) Intel Server Board SE7520JR2 Technical Product Specification (available on support.intel.com) Intel Server Board SE7520AF2 Technical Product Specification (available on support.intel.com) Intel Server Board SE7520AF2 User Guide (provided with the server board and available on support.intel.com) Intel Server Board SE7520JR2 User Guide (provided with the server board and available on support.intel.com) Intel Server Board SE7520BN2 User Guide (provided with the server board and available on support.intel.com) Intel Server Board SE8500HW4 User Guide (provided with the server board and available on support.intel.com) Getting Started with Intel Server Manager 8 (ISM 8) (ism_getting_started_guide.pdf). This document is installed by the ISM installer from the ISM CD provided with the server board. Installing and Configuring the Intel Server Manager 8 SNMP Subagents (SNMP_Subagent_Install_and_Config_Guide.pdf). This document is installed by the ISM installer from the ISM CD provided with the server board. IPMI Intelligent Platform Management Interface Specification Second Generation v2.0, see for the latest specification and errata. Intel Management Module Installation and User s Guide 31
32 Glossary Term BIOS BMC CLI DIMM FRU HSC I2C ICMB ID IPMI ISM KVM LED mbmc MIB NIC NMS OOB PCI SATA SDR SEL SCSI SCW SNMP SMBus SMTP TPS Definition Basic Input Output System Baseboard Management Controller Command Line Interface Dual In-line Memory Module Field Replaceable Unit Hot-swap Controller Inter-Integrated Circuit Bus Intelligent Chassis Management Bus Identification Intelligent Platform Management Interface Intel Server Manager Keyboard Video Mouse Light Emitting Diode mini-baseboard Management Controller (National Semiconductor PC87431) Management Information Base Network Interface Card Network Management Station Out of Band (management of the server without the server Operating System) Peripheral Component Interconnect bus Serial ATA (Advanced Technology Attachment) Sensor Data Record System Event Log Small Computer System Interface Intel Server Configuration Wizard Simple Network Management Protocol System Management Bus Simple Mail Transfer Protocol Technical Product Specification 32 Intel Management Module Installation and User s Guide
Command Line Interface User Guide for Intel Server Management Software
Command Line Interface User Guide for Intel Server Management Software Legal Information Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel
Installing and Configuring the Intel Server Manager 8 SNMP Subagents. Intel Server Manager 8.40
Installing and Configuring the Intel Server Manager 8 SNMP Subagents Intel Server Manager 8.40 Legal Information This Installing and Configuring the Intel Server Manager 8 SNMP Subagents--Intel Server
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset) Version: 1.4 Table of Contents Using Your Gigabyte Management Console... 3 Gigabyte Management Console Key Features and Functions...
Intel N440BX Server System Event Log (SEL) Error Messages
Intel N440BX Server System Event Log (SEL) Error Messages Revision 1.00 5/11/98 Copyright 1998 Intel Corporation DISCLAIMERS Information in this document is provided in connection with Intel products.
C440GX+ System Event Log (SEL) Messages
C440GX+ System Event Log (SEL) Messages Revision 0.40 4/15/99 Revision Information Revision Date Change 0.40 4/15/99 Changed BIOS Events 0C EF E7 20, 0C EF E7 21 to 0C EF E7 40, 0C EF E7 41 Disclaimers
Intel Command Line Interface
Intel Command Line Interface User Guide Intel Command Line Interface Version 2.4 Legal Information INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS FOR THE PURPOSE OF SUPPORTING
Intel Simple Network Management Protocol (SNMP) Subagent v6.0
Intel Simple Network Management Protocol (SNMP) Subagent v6.0 User Guide March 2013 ii Intel SNMP Subagent User s Guide Legal Information INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL
Exploring the Remote Access Configuration Utility
Exploring the Remote Access Configuration Utility in Ninth-Generation Dell PowerEdge Servers The Remote Access Configuration Utility supports local and remote server management in ninth-generation Dell
System Area Manager. Remote Management
System Area Manager Remote Management Remote Management System Area Manager provides remote management functions for its managed systems, including Wake on LAN, Shutdown, Restart, Remote Console and for
System Event Log (SEL) Viewer User Guide
System Event Log (SEL) Viewer User Guide ROM-DOS Version Part Number: D67749-001 Disclaimer This, as well as the software described in it, is furnished under license and may only be used or copied in accordance
Server Management on Intel Server Boards and Intel Server Platforms. Revision 1.0 March 2009
Server Management on Intel Server Boards and Intel Server Platforms Revision 1.0 March 2009 Revision History Date Revision Description March 2008 0.5 Initial release. April 2008 0.9 Updated it for all
McAfee Firewall Enterprise
Hardware Guide Revision C McAfee Firewall Enterprise S1104, S2008, S3008 The McAfee Firewall Enterprise Hardware Product Guide describes the features and capabilities of appliance models S1104, S2008,
Understanding DRAC/MC Alerts
Understanding DRAC/MC Alerts The Dell Remote Access Controller/Modular Chassis (DRAC/MC) provides various alerting mechanisms by which administrators can monitor and manage the components within a Dell
System Event Log (SEL) Viewer User Guide
System Event Log (SEL) Viewer User Guide For Extensible Firmware Interface (EFI) and Microsoft Preinstallation Environment Part Number: E12461-001 Disclaimer INFORMATION IN THIS DOCUMENT IS PROVIDED IN
Foglight Experience Monitor and Foglight Experience Viewer
Foglight Experience Monitor and Foglight Experience Viewer Quest Software, Inc. April 2008 Using the Dell Remote Access Controller Copyright Quest Software, Inc. 2008. All rights reserved. This guide contains
This chapter explains a preparation for the use of RemoteControlService.
ServerView User's Guide (For RemoteControlService) Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview of RemoteControlService
Server Management on Intel Server Boards and Intel Server Platforms. Revision 1.1 September 2009
Server Management on Intel Server Boards and Intel Server Platforms Revision 1.1 September 2009 Revision History Date Revision Description March 2008 0.5 Initial release. April 2008 0.9 Updated it for
Intel RAID Controller Troubleshooting Guide
Intel RAID Controller Troubleshooting Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Intel order number C18781-001 September 2, 2002 Revision History Troubleshooting
Intel Active Management Technology with System Defense Feature Quick Start Guide
Intel Active Management Technology with System Defense Feature Quick Start Guide Introduction...3 Basic Functions... 3 System Requirements... 3 Configuring the Client System...4 Intel Management Engine
Gigabyte Content Management System Console User s Guide. Version: 0.1
Gigabyte Content Management System Console User s Guide Version: 0.1 Table of Contents Using Your Gigabyte Content Management System Console... 2 Gigabyte Content Management System Key Features and Functions...
Monthly Specification Update
Monthly Specification Update Intel Server Board S1400FP Family August, 2013 Enterprise Platforms and Services Marketing Enterprise Platforms and Services Marketing Monthly Specification Update Revision
Intel Entry Storage System SS4000-E
Intel Entry Storage System SS4000-E Software Release Notes March, 2006 Storage Systems Technical Marketing Revision History Intel Entry Storage System SS4000-E Revision History Revision Date Number 3 Mar
AST2150 IPMI Configuration Guide
AST2150 IPMI Configuration Guide Version 1.1 Copyright Copyright 2011 MiTAC International Corporation. All rights reserved. No part of this manual may be reproduced or translated without prior written
Intel System Event Log (SEL) Viewer Utility
Intel System Event Log (SEL) Viewer Utility User Guide Document No. E12461-003 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS FOR THE GENERAL PURPOSE OF SUPPORTING
Configuring and Using AMT on TS140 and TS440
Configuring and Using AMT on TS140 and TS440 Lenovo ThinkServer TS Series Servers Lenovo Enterprise Product Group Version 1.0 September 17, 2013 2013 Lenovo. All rights reserved. LENOVO PROVIDES THIS PUBLICATION
IPMI overview. Power. I/O expansion. Peripheral UPS logging RAID. power control. recovery. inventory. Hugo Caçote @ CERN-FIO-DS
Intelligent Platform Management Interface IPMI Server Management IPMI chronology PROMOTERS 1998 IPMI v1.0 2001 IPMI v1.5 2004 IPMI v2.0 IPMI overview power control Power monitor Rack Mount alert Blade
Intel Server Boards and Server Platforms Server Management Guide
Intel Server Boards and Server Platforms Server Management Guide Intel part number: G37830-002 October 2012 Revision History Revision History Date Revision Description March 2008 0.5 Initial release. April
Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.
Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of
Server Management with Lenovo ThinkServer System Manager
Server Management with Lenovo ThinkServer System Manager For next-generation Lenovo ThinkServer systems Lenovo Enterprise Product Group Version 1.0 September 2014 2014 Lenovo. All rights reserved. LENOVO
Monthly Specification Update
Intel Server Board S1200BTLR Intel Server Board S1200BTSR Intel Server Board S1200BTLRM Intel Server System R1304BTLSFANR Intel Server System R1304BTSSFANR Intel Server System R1304BTLSHBNR Intel Server
ThinkServer RD230 and RD240 Remote Management User Guide
ThinkServer RD230 and RD240 Remote Management User Guide ThinkServer RD230 and RD240 Remote Management User Guide Note: Before using this information and the product it supports, be sure to read and understand
NEC Express5800 Series NEC ESMPRO AlertManager User's Guide
NEC Express5800 Series NEC ESMPRO AlertManager User's Guide 7-2006 ONL-4152aN-COMMON-128-99-0606 PROPRIETARY NOTICE AND LIABILITY DISCLAIMER The information disclosed in this document, including all designs
SyAM Software* Server Monitor Local/Central* on a Microsoft* Windows* Operating System
SyAM Software* Server Monitor Local/Central* on a Microsoft* Windows* Operating System with Internal Storage Focusing on IPMI Out of Band Management Recipe ID: 19SYAM190000000011-01 Contents Hardware Components...3
Intel System Event Log (SEL) Viewer Utility
Intel System Event Log (SEL) Viewer Utility User Guide Document No. E12461-007 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS FOR THE GENERAL PURPOSE OF SUPPORTING
Intel System Event Log (SEL) Viewer Utility
Intel System Event Log (SEL) Viewer Utility User Guide Document No. E12461-005 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS FOR THE GENERAL PURPOSE OF SUPPORTING
Intel Desktop Board D925XECV2 Specification Update
Intel Desktop Board D925XECV2 Specification Update Release Date: July 2006 Order Number: C94210-005US The Intel Desktop Board D925XECV2 may contain design defects or errors known as errata, which may cause
Chapter 3 Management. Remote Management
Chapter 3 Management This chapter describes how to use the management features of your ProSafe 802.11a/g Dual Band Wireless Access Point WAG102. To access these features, connect to the WAG102 as described
Intel Management Engine BIOS Extension (Intel MEBX) User s Guide
Intel Management Engine BIOS Extension (Intel MEBX) User s Guide User s Guide For systems based on Intel B75 Chipset August 2012 Revision 1.0 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH
Intel Server Control User s Guide
Legal Information Intel Server Control User s Guide Version 2.3 Part Number: A09225-004 About Intel Server Control Finding the Right Tool Managing Remote Servers Connecting to a Remote Server Paging an
Intel RAID Volume Recovery Procedures
Intel RAID Volume Recovery Procedures Revision 1.0 12/20/01 Revision History Date Revision Number 12/20/01 1.0 Release Modifications Disclaimers Information in this document is provided in connection with
User s Manual Network Management Card
User s Manual Network Management Card RMCARD202 Intelligent Network Management Card allows a UPS system to be managed, monitored, and configured Version 1.0 E-K01-SNMP005-0 TABLE OF CONTENTS Introduction
System Release Notes Express5800/320LB System Release Notes
System Release Notes Express5800/320LB System Release Notes PN: 455-01681-004 2 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related
Intel System Event Log (SEL) Viewer Utility. User Guide SELViewer Version 10.0 /11.0 December 2012 Document number: G88216-001
Intel System Event Log (SEL) Viewer Utility User Guide SELViewer Version 10.0 /11.0 December 2012 Document number: G88216-001 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH
Hardware Monitoring with the new Nagios IPMI Plugin
Hardware Monitoring with the new Nagios IPMI Plugin Werner Fischer Technology Specialist Thomas-Krenn.AG LinuxTag 2010 Berlin, 10.06.2010 Agenda 1) About Thomas Krenn 2) IPMI basics 3) Nagios IPMI Sensor
RSA Security Analytics. S4 Broker Setup Guide
RSA Security Analytics S4 Broker Setup Guide Copyright 2010-2013 RSA, the Security Division of EMC. All rights reserved. Trademarks RSA, the RSA Logo and EMC are either registered trademarks or trademarks
Compaq Presario Desktop Products. Upgrading and Servicing Guide
Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to
Wash Select II to WashPay Integration Field Retrofit Installation Guide
Wash Select II to WashPay Integration Field Retrofit Installation Guide Wash Select II Software Version 6.00 and above POS4000 Software Version 8.25 Unitec www.startwithunitec.com WASH SELECT II TO WASHPAY
SyAM Software, Inc. Server Monitor Desktop Monitor Notebook Monitor V3.2 Local System Management Software User Manual
SyAM Software, Inc. Server Monitor Desktop Monitor Notebook Monitor V3.2 Local System Management Software User Manual Revision A August 2006 1 2006 SyAM Software, Inc. All rights reserved. SyAM Software
QuickSpecs. Overview. Compaq Remote Insight Lights-Out Edition
Overview M ODELS Remote Insight Lights-Out Edition 157866-001 New Remote Insight Lights-Out Edition provides virtual graphical control using any standard browser to your remote or data centre server, giving
Installation and User Guide. for. Acer Server Manager Enterprise (ASMe) Ver. 5.1
Installation and User Guide for Acer Server Manager Enterprise (ASMe) Ver. 5.1 Legal Information Information in this document is provided in connection with Intel products. No license, express or implied,
Chapter 4 Management. Viewing the Activity Log
Chapter 4 Management This chapter describes how to use the management features of your NETGEAR WG102 ProSafe 802.11g Wireless Access Point. To get to these features, connect to the WG102 as described in
User s Manual UPS SERIES. Network Interface Card UPS-IPCARD. I-00453 Rev B
User s Manual UPS SERIES Network Interface Card UPS-IPCARD I-00453 Rev B TABLE OF CONTENTS INTRODUCTION............................................................. 3-4 INSTALLATION GUIDE.......................................................
Overview of ServerView Windows Agent This chapter explains overview of ServerView Windows Agent, and system requirements.
ServerView User s Guide (For Windows Agent) Areas Covered - Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview of ServerView
Broadband Router ESG-103. User s Guide
Broadband Router ESG-103 User s Guide FCC Warning This equipment has been tested and found to comply with the limits for Class A & Class B digital device, pursuant to Part 15 of the FCC rules. These limits
Enhancements to idrac7 Alert Notification
Enhancements to idrac7 Alert Notification This Dell white paper discusses the improvements made to the idrac7 version 1.30.30 alerting capabilities Test Engineer Enterprise Software Validation Test Engineer
McAfee Data Loss Prevention
Hardware Guide Revision B McAfee Data Loss Prevention 1650, 3650, 4400, 5500 This guide describes the features and capabilities of McAfee Data Loss Prevention (McAfee DLP) appliances to help you to manage
Remote Supervisor Adapter II. User s Guide
Remote Supervisor Adapter II User s Guide Remote Supervisor Adapter II User s Guide Note: Before using this information and the product it supports, read the general information in Appendix B, Notices,
Intel RAID Software v6.x (and newer) Upgrade/Installation Procedures
Intel RAID Software v6.x (and newer) Upgrade/Installation Procedures For Intel Server RAID Controller U3-1 and Intel Server RAID Controller U3-1L Revision 1.1 12/21/01 Date Rev Modifications 12/21/01 1.1
PRIMERGY BX Blade Server Systems. RemoteView Management Blade User Interface Description
PRIMERGY BX Blade Server Systems RemoteView Management Blade User Interface Edition November 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this
Intel vpro Provisioning
Intel vpro Provisioning Introduction............................................................ 2 AMT Setup and Configuration............................................... 2 SMB Mode - AMT Setup and
IPMI Coniguration Guide
IPMI Coniguration Guide 1. Introduction of Megarac SP... 2 2. Megarac SP GUI Overview... 3 1 1. Introduction of Megarac SP Megarac SP allows remote access of computers with BMC (Baseboard Management Controllers)
Title Page Web/SNMP Management SmartSlot Card
Title Page Web/SNMP Management SmartSlot Card AP9606 User s Guide Thank You! Thank you for selecting the APC Web/SNMP Management SmartSlot Card. It has been designed for many years of reliable, maintenance-free
This guide explains how to install an Intel Solid-State Drive (Intel SSD) in a SATA-based desktop or notebook computer.
Installation Guide This guide explains how to install an (Intel SSD) in a SATA-based desktop or notebook computer. The instructions include migrating your data from your current storage device (such as
PREFACE http://www.okiprintingsolutions.com 07108001 iss.01 -
Network Guide PREFACE Every effort has been made to ensure that the information in this document is complete, accurate, and up-to-date. The manufacturer assumes no responsibility for the results of errors
Dell Server Management Pack Suite Version 6.0 for Microsoft System Center Operations Manager User's Guide
Dell Server Management Pack Suite Version 6.0 for Microsoft System Center Operations Manager User's Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make
Setting Up a Unisphere Management Station for the VNX Series P/N 300-011-796 Revision A01 January 5, 2010
Setting Up a Unisphere Management Station for the VNX Series P/N 300-011-796 Revision A01 January 5, 2010 This document describes the different types of Unisphere management stations and tells how to install
Network Management Card. User Manual
User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1
AXIS Camera Station Quick Installation Guide
AXIS Camera Station Quick Installation Guide Copyright Axis Communications AB April 2005 Rev. 3.5 Part Number 23997 1 Table of Contents Regulatory Information.................................. 3 AXIS Camera
SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3
SIP Proxy Server Administrator Installation and Configuration Guide V2.31b 09SIPXM.SY2.31b.EN3 DSG, DSG logo, InterPBX, InterServer, Blaze Series, VG5000, VG7000, IP590, IP580, IP500, IP510, InterConsole,
Symantec Database Security and Audit 3100 Series Appliance. Getting Started Guide
Symantec Database Security and Audit 3100 Series Appliance Getting Started Guide Symantec Database Security and Audit 3100 Series Getting Started Guide The software described in this book is furnished
Installation Guide. Wyse C Class Conversion to WES7. Wyse USB Firmware Tool TM Release 1.10. Issue: 102910 PN: 883887-17L Rev. B
Installation Guide Wyse C Class Conversion to WES7 Wyse USB Firmware Tool TM Release 1.10 Issue: 102910 PN: 883887-17L Rev. B Copyright Notices 2010, Wyse Technology Inc. All rights reserved. This manual
Legal Disclaimers. For C-UL Listed applications, the unit shall be installed in accordance with Part 1 of the Canadian Electrical Code.
ACS5000 Networking Admin Interface Guide 1/21/2015 Legal Disclaimers Federal Communications Commission (FCC) Compliancy This equipment has been tested and found to comply with the limits for a Class B
Intel One Boot Flash Update Utility
Intel One Boot Flash Update Utility User Guide February 2012 Document Number: E71543-005 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS FOR THE PURPOSE OF SUPPORTING
Upgrading and Servicing Guide
Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed
Contents. Preparation/SetUp...2
LAN Control Utility User Manual (for MH850U) Contents Preparation/SetUp... Preparation before using the network function... Connection...3 Installation...3 Setting the IP address of the projector...5 When
Welcome. Unleash Your Phone
User Manual Welcome Unleash Your Phone For assistance with installation or troubleshooting common problems, please refer to this User Manual or Quick Installation Guide. Please visit www.vonage.com/vta
9 Headless Systems & Remote Management
9 Headless Systems & Remote Management Headless support is a key feature of XPe. Since the nature of the XP operating system is to have a graphical interface, designing an XPe headless device involves
USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks
USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu,
Installing Microsoft Windows Server 2008R2 with EasyStartup
Installing Microsoft Windows Server 2008R2 with EasyStartup Version 1.5 1/11/2013 LENOVO PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED
SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems
SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and
How to Set Up Your NSM4000 Appliance
How to Set Up Your NSM4000 Appliance Juniper Networks NSM4000 is an appliance version of Network and Security Manager (NSM), a software application that centralizes control and management of your Juniper
PROMISE ARRAY MANAGEMENT (PAM) for
PROMISE ARRAY MANAGEMENT (PAM) for FastTrak SX4030, SX4060 and S150 SX4-M User Manual Version 1.1 PAM for FastTrak SX4030, SX4060 and S150 SX4-M User Manual Copyright 2004 Promise Technology, Inc. All
Express5800/320Lb System Release Notes
System Release Notes Express5800/320Lb System Release Notes PN: 455-01681-004 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
SNMP Manager User s Manual
SNMP Manager User s Manual Table of Contents 1. Introduction...2 2. SNMP Manager Install, Quick Start and Uninstall...2 2.1. Software Installation...2 2.2. Software Quick Start...2 2.3. Software Uninstall...2
Cisco TelePresence VCR MSE 8220
Cisco TelePresence VCR MSE 8220 Getting started 61-0008-05 Contents General information... 3 About the Cisco TelePresence VCR MSE 8220... 3 Port and LED location... 3 LED behavior... 4 Installing the VCR
Focal Point 2.1 Management Software & CPSMM100 Firmware Manual
Focal Point 2.1 Management Software & CPSMM100 Firmware Manual Manual 33293 Rev B Focal Point Management Software Transition Networks Table of Contents Section I:...1 Introduction...1 About this manual...2
Intel Unite Solution. Standalone User Guide
Intel Unite Solution Standalone User Guide Legal Disclaimers & Copyrights All information provided here is subject to change without notice. Contact your Intel representative to obtain the latest Intel
Out-of-Band Management Reference
www.novell.com/documentation Out-of-Band Management Reference ZENworks 11 Support Pack 3 Beta February 2014 Legal Notices Novell, Inc., makes no representations or warranties with respect to the contents
Dell OpenManage SNMP Reference Guide Version 8.0.1
Dell OpenManage SNMP Reference Guide Version 8.0.1 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates
Intel Compute Stick STCK1A32WFC User Guide. Intel Compute Stick STCK1A32WFC
Intel Compute Stick STCK1A32WFC User Guide 1 Revision History Revision Revisions History Date 01 First release of the Intel Compute Stick STCK1A32WFC User Guide April 2015 Disclaimer INFORMATION IN THIS
9236245 Issue 2EN. Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation
9236245 Issue 2EN Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation Nokia 9300 Configuring connection settings Legal Notice Copyright Nokia 2005. All rights reserved. Reproduction,
Type Message Description Probable Cause Suggested Action. Fan in the system is not functioning or room temperature
Table of Content Error Messages List... 2 Troubleshooting the Storage System... 3 I can t access the Manager... 3 I forgot the password for logging in to the Manager... 3 The users can t access the shared
Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive
Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive This guide explains how to create and use a Rescue USB flash drive to reinstall and recover the ExtraHop system. When booting
DPXR4X1A-16NP, DPXS20A-16AU-M,
- 1 - Release Notes for Dominion PX Software Version 1.3.5 (firmware version will be displayed as 01.03.05 in the GUI after an upgrade) Version: DPX 1.3.5 Release Notes, Revision 1.1 Date: June 8, 2009
026-1010 Rev 7 06-OCT-2011. Site Manager Installation Guide
026-1010 Rev 7 06-OCT-2011 Site Manager Installation Guide Retail Solutions 3240 Town Point Drive NW, Suite 100 Kennesaw, GA 30144, USA Phone: 770-425-2724 Fax: 770-425-9319 Table of Contents 1 SERVER
Network Management Card
Network Management Card AP9617 AP9618 AP9619 Installation and Quick-Start Manual How to Avoid Equipment Damage Disconnect UPS power You do not need to turn off a Symmetra or a Silcon model UPS to install
BIOS Update Release Notes
BIOS Update Release Notes PRODUCTS: DH55TC, DH55HC, DH55PJ (Standard BIOS) BIOS Version 0040 - TCIBX10H.86A.0040.2010.1018.1100 October 18, 2010 Integrated Graphics Option ROM Revision on HC/TC: 2017 PC
Barracuda Link Balancer Administrator s Guide
Barracuda Link Balancer Administrator s Guide Version 1.0 Barracuda Networks Inc. 3175 S. Winchester Blvd. Campbell, CA 95008 http://www.barracuda.com Copyright Notice Copyright 2008, Barracuda Networks
Job Aid: Replacing the Hard Drive on the Avaya S8710 Media Servers R2.2 or Later
Job Aid: Replacing the Hard Drive on the Avaya S8710 Media Servers R2.2 or Later This job aid describes the steps required to replace the hard drive on an Avaya S8710 Media Servers running Release 2.2
Securely manage data center and network equipment from anywhere in the world.
LES1516A LES1532A LES1548A Secure Server with Cisco Pinout Securely manage data center and network equipment from anywhere in the world. To download the user manual, this quick start guide, and software
