RESEARCH ON DECREASE OF OUTSIDE AIR HEAT PUMP PASSIVE EVAPORATORS ICE-COVER
|
|
|
- Patience Mills
- 10 years ago
- Views:
Transcription
1 ISSN ISBN Environment. Technology. Resources Proceedings of the 8th International Scientific and Practical Conference. Volume 1 Rēzeknes Augstskola, Rēzekne, RA Izdevniecība, 2011 RESEARCH ON DECREASE OF OUTSIDE AIR HEAT PUMP PASSIVE Andrievs Ilsters, Imants Ziemelis Latvia University of Agriculture, Research Institute of Agricultural Machinery 1 Instituta St, Ulbroka, Riga region, Latvia [email protected]; [email protected] Abstract. Two years ( ) experience of the experimental use of alternative energy sources in technological processes of agriculture is analyzed. Water was heated by an outside air heat pump with passive evaporators, and used for new born piglets resting place floor heating. Experimental data were obtained by the reckoning consumption of electric energy for the operation of the heat pump s compressor and electric heater, and by a heat meter registering the consumed heat energy. The obtained data show that the outside air heat pump with passive evaporators is working successfully during summer months, when the coefficient of performance (COP) of the heat pump exceeds 3.5. When the outside temperature decreases under +10 C, the heat pump evaporators become covered with hoarfrost and ice. The value of the COP and produced amount of heat energy reduce, and the electric heater often switches on. During the experimental research one of the heat pump evaporators was supplied with a ventilator, air flow from which was washing the surface of the evaporator s plates. So the satisfactory operation of the heat pump was provided till December 10, 2009 and November 25, Keywords: coefficient of performance, heat pump, ice coverage. Introduction In order to widen the use of renewable energy sources in Latvia, detailed investigation, advance and support on technological investigation issues is needed. Particularly it concerns the use of heat pumps in the climatic conditions of Latvia. It is important to find out its place in the energy supply system for today and future [1]. Producers and disseminators of heat pumps are organizing impressive reclamation campaigns with recommendations on the use of heat pumps for living house heating, particularly when heated floors are introduced. The heat energy can be taken from the ground, water or air. An attention deserves the latest projects, realised in Latvia, about the use of heat pumps, where the heat is taken from the sea (Salacgriva) and the lake (Katvari). The efficiency of an outside air heat pump essentially depends on the air temperature. The heat transformation ability is determined by coherence [2]: TH COP, (1) TH TL where COP coefficient of performance of the heat pump; T H highest (necessary for consumer) temperature, C; T L lowest (heat source) temperature, C. The heat pump s coefficient of performance (COP) is smaller at lower value of the outside air temperature. It is exactly when the need for heat is the highest. Therefore in case when the heat pump is not able to produce the necessary amount of heat energy, additional heat producing advices are envisaged. Conditions, different from living houses are in warmed domestic animal cattle-sheds, where intensive ventilation system is working. There polluted inside air is delivered out from the premises and the fresh and clean air is brought in. With the polluted air considerable amount of heat is lost. At the same time in order to maintain the necessary temperature inside the sucking and weaned piglet premises, all the year round electric heaters or heating boilers are used. The fossil energy consumption rises and the environment becomes spoiled. 197
2 By setting up pigsties with heat pumps of an appropriate power, during the period of hot weather it is possible to provide for heating piglets resting place floor without using additional heaters. Working out the solution of recovering the heat from brought out by ventilation system polluted but warm air, it could be possible to provide for heat pump operation at lower outside temperature, that is, during the heating period also. As a result the consumption of fossil energy would be diminished. The objective of the research is to ascertain the suitability of the use of outside air heat pump for piglets resting place floor heating, putting particular attention to the possibility of providing for high heat transmission coefficient (COP) of the heat pump during could and frosty weather conditions. Materials and methods For the experimental investigation an outside air heat pump with passive evaporators has been used. The compressor of the heat pump is driven by the electric motor of 5 kw power. The power of produced heat energy is up to 17 kw. The power of additional electric heater is 12 kw. The heat pump was installed at one of sows farrowing sections with two compartments, where 96 farrowing places are set. The passive evaporators are places outside the piggery, but compressor and other equipment inside the piggery. The hot water, heated by the heat pump up to C by means of a circulation pump through the pipe system to each of farrowing pens with heating floor panels has been delivered. The heat load of each of heating panels is 180 W. During the experimental investigation the panels surface temperature within the limits of C has been kept. The circulation pump operation regime after the back flow water temperature has been controlled, keeping it within the limits of C. Data about the produced amount of heat energy and consumed electric energy for heat pump compressor s and electric heater operation have been registered. The efficiency of the heat pump operation during certain periods has been estimated, establishing the COP and energy transfer coefficients using coherencies [1] Q COP (2) P c Q K (3) P where K energy transfer coefficient; Q produced amount of heat energy, kwh; P c electric energy consumed for compressor s operation, kwh; P total consumption of electric energy, kwh. For the registration of the consumed electric energy two 3-faze electric meters has been used, with the accuracy 0.01 kwh. One of them registered the electric energy consumed for the operation of the heat pump s compressor, and another one, additionally consumed electric energy by the electric heater. Produced amount of heat by the use of heat meter SONOMETER TM 1000 (accuracy 1 kwh) has been measured. The heat meter allows in every time moment to read of the efficiency of the hot water flow, the temperature of the heated floor inflow and outflow water, and the heat energy power as well. Average daily and monthly outside air temperatures during the experiment from the data base of the State Meteorological Service has been taken [3]. In order to carry out the experimental investigation on the possibility of the decrease of hoarfrost and ice coverage of the heat pump evaporators, one of them was provided for a ventilator (efficiency m 3 /s), which air flow on the evaporators plates has been directed. 198
3 Results and Discussion The heat energy, produced by the heat pump, was used for piglets resting place floor panels heating. From the data given in Table 1, about the exploitation parameters of the heat pump obtained in 2009 and 2010, firstly, direct relationship between the outside air temperature and COP of the heat pump is seen. Secondly, during the warm months of the summer July and August, the consumption of heat is essentially smaller. The heat pump all the necessary amount of heat is able to produce with breaks at COP >3.5. At the temperature under 10 C and down to the positive temperature above 0 C, the character of the operation of the heat pump changed. Particularly it is seen from the data about October and November, when the average temperature was 5-6 C and the evaporators plates started to be covered with hoarfrost and ice. The demand of heat for keeping the floor temperature in the necessary level increases also. The heat pump s compressor in the majority was working continuously. Not always the ice thawed from the heat evaporator plates, when the temperature in the middle of a day increased. As a result the COP of the heat pump felt down to The common heat transfer coefficient reduced to In certain time periods, particularly in nights, the electric heater switched on. The hoarfrost of radial placed evaporators plates increased so intensively that the evaporators entirely were covered by the ice and visually took a cylindrical shape. Table 1. Exploitation indexes of the heat pump with passive evaporators in 2009 and 2010 Average outside air temperature, o C Specific heat consumption, kwh/h Compressors common COP Months May June July August September Oktober November December Average Technical solutions for the diminishing of the hoarfrost and taking off the ice from the evaporators plates have been looked for. They are based on the direction of the warm air flow on the evaporators plates. The first investigations in the exploitation season of 2009 have been carried out. Around one of the evaporator blocs an isolation square box, where by means of a ventilator from one side the air from outside or the pigsty ante-room has been blown in. The average increase in heat energy power by kw has been obtained and the thaw of hoarfrost has been furthered [4]. During the further work this principle has been changed. The additional air flow was directed parallel to the evaporator s plates. It was completed placing the ventilator above the evaporator s block and by means of a special cone moving the air flow to the evaporator s plates (Fig.1). In order to intensify the process, the possibility to cover the evaporator s block from both outside and inside with special screens has been envisage. K 199
4 Air Fig.1. Scheme of screens for air flow movement parallel to evaporator plates: 1 air canal; 2 ventilator; 3 cover; 4 cone; 5 inside screen (movable); 6 outside screen (movable); 7 evaporator s block Fig.2. Ventilator above the heat pump evaporator Experimental results on the promotion of the ice thaw from the evaporator s plates by short time moving the air flow to evaporator s plates, and by long time moving the air flow to evaporator s plates in order to improve the heat pump operation. Results in Table 2 when the air flow is directed to the evaporator s plates, corresponds to regime 1. Period of time from September 1 to September 9 the heat pump was working in constant regime 0. Consumption of heat on the average was 9.5 kwh/h at the COP = In the morning of September 9 at the outside air temperature 9 10 C the evaporator s plates were covered by the hoarfrost, and the heat pump was working continuously with heat power kw, at the COP = In the next morning (September 10) at similar weather conditions switching on the ventilator and starting to direct the air flow to the evaporators plates, during several minutes the heat power from 10.4 kw increased to 12.5 kw. The compressor switched off and the thaw of the evaporator s plates started. When the compressor switched on next time, the heat power rose up to 13.8 kw. After some time when the ventilator was switched off, the heat power diminished a little, because the evaporator plates already were free from hoarfrost. Similar examination was repeated several times. The main gain from the additional switching on and off of the ventilator is to contribute to the thawing of the evaporators plates, which after that improves the parameters of the neat pump for longer time. Greater effect has been reached at additional operation of the ventilator in the first week of October (2009), when the temperature lowered under 5 8 C. On October 9 the ventilator has been operating all the day round (Fig.2). At the heat consumption 12.8 kwh/h the reached heat power was 15.2 kw at the COP = 3.08, including the energy consumed for the ventilator s operation K = 2.64). The two last rows in Table 2 reflect the average results of the long term operation of the heat pump at outside air temperature 5-6 C. From October 5 to 10 when the ventilator was out of operation, the compressor s COP on the average was As for some time the electric heater has been operating, the common energy transfer coefficient was K =
5 From October 10 till November 4 the ventilator was operating constantly. Therefore the hoarfrost essentially reduced, the air flow around the evaporator s plates was more intensive and the electric heater did not switch on. In result at the average heat consumption 12.2 kwh/h the compressor s COP increased up to 2.89, and including the ventilator s consumed power, the common coefficient K was Increase in heat pump operation results in September-October, 2010 coursed by outside air flow Table 2. Date R Outside air Q, Time, temperature, o N, COP K C kwh/ h kw average min max h Sept Sept Sept Sept Sept Oct Oct Oct Oct Oct Oct Oct. 10 Nov Designations: R regimes, 0 without air flow, 1 with outside air flow, N produced heat power, Q consumption of heat energy, COP compressor s coefficient of performance, K - common energy transfer coefficient. In Table 3 experimental results when outside air temperature was under +6 o C, and the evaporator was heated by outside or inside air flow using a ventilator (November, 2010), are presented. On November 4 afternoons at the outside air temperature +9 o C the heat power reached 14.3 kw. During the night temperature decreased and in the morning November 4 it was only +3 o C. The evaporators were slightly cowered with hoarfrost and the heat power has diminished to 9.9 kw. At switching on the ventilator with outside air flow after 5 minutes the heat power increase by 1,2 kw and later reached 13.7 kw, although hoarfrost of the evaporator s plates did not thaw. When warm air (+10 o C) from the ante-room was blown to the evaporator, fast hoarfrost thaw started and the heat power increased up to 15.7 kw. At switching the ventilator off and on repeatedly, the heat power changed correspondingly. Similar investigations several times during a week have been carried out. Always it resulted in the increase of produced heat power and the COP of the heat pump. 201
6 Evaporator s heating by outside or inside air flow in November, 2010 Table 3. Date R Time, T o Q, N, kw h out, C kwh/h from up to difference COP K Designations: R regimes, 0 without air flow, 1 with outside air flow, 2 with outside and inside air flow, 3 with inside air flow only, T out average outside air temperature, N produced heat power, Q consumption of heat energy, COP compressor s coefficient of performance, K - common energy transfer coefficient. Experimental results, when the outside air flow was directed to the evaporator covered by screens, in Table 4 are presented. One of experiments on October 6 when outside temperature reached +7 o C has been carried out. In the morning both evaporators were covered by hoarfrost. In the afternoon at p.m. the ventilator was switched on. In 10 minutes the heat power of the non-covered evaporator increased from 11.3 kw to 14.2 kw. After switching off the ventilator in 25 minutes the heat power diminished to 11.3 kw and the evaporator s plates did not thaw. After that a row of experiments have been carried out using the screens around the evaporator from outside and inside. Warm air flow (+12 o C) from the ante-room was delivered to the evaporator. Fast heat power increase started, reaching its maximum at 15.4 kw. The COP of the heat pump increased accordingly from 2.5 to 3.4. When the screens were taken off the indexes decreased (Table 4). Experimental results when the evaporator covered by screens (2010) Table 4. Date R Time, h T out, Q, Heat power, o C kwh/h kw COP Common K Nov * Nov ** 1 1,7 10* Designations: R regimes, 0 without air flow, 1 with inside air flow, T out average outside air temperature, Q consumption of heat energy, COP compressor s coefficient of performance, K - common energy transfer coefficient, * - air temperature in ante-room, ** - for short time the electric heater is switched on. 202
7 Power, kw; Temperature, Ilsters A., Ziemelis I. RESEARCH ON DECREASE OF OUTSIDE AIR HEAT PUMP PASSIVE The process of the investigation in Fig.2 is shown. Steep increase in the heat power just after switching on the ventilator in Fig.3 is seen. Similar results in repeated experiments are obtained. The evaporator block with opened screens after thawing in Fig.4 is given. On the left side (Fig.4) another evaporator s block is seen, which at the same time did not thaw. Power, kw o C Time, h COP 3.5 Nh Tout COP Fig.2. The gain of the COP and heat energy power N h of the heat pump: T out outside air temperature Time, min Fig.3. The dynamics of the gain in power during 4 minutes after the start of warm air flow: upper curve with screen, lower - without screen Fig.4. The evaporator block with opened screens after thawing Conclusions From our two years investigation results about the possibility of the use of an outside air heat pump for piglets resting place floor panels heating, the following is concluded: 1. In summer period at the outside air temperature above o C the coefficient of performance of a heat pump is above 3 and the heat consumption 5 9 kwh/h. The evaporators of the heat pump are not covered by hoarfrost. 2. At outside air temperature 3-10 o C the heat demand increases. The heat pump operates constantly or with small breaks. The evaporators start to be covered by hoarfrost. The exploitation indexes of the heat pump decreases. The heat transfer coefficient becomes fewer than At the positive outside air temperature within the limits of 2-5 o C the evaporators coverage by hoarfrost increases, and without additional undertakings to this, the heat pump operation is not useful. 4. The thawing of the hoarfrost using additional air flow in successful only in the outside temperature interval 6-12 o C. 203
8 5. At the outside air temperature under 12 o C it is recommended to blow the heat pump evaporators by warmed air flow. In our experimental examination the obtained gain of the heat power was by kw, and the COP of the heat pump increased by on the average. 6. The investigation has shown that the blowing of the evaporators by warmed air can prolong the operation of the heat pump at lower outside temperature period. In our experimental pigsty using the transformed by a heat pump the heat energy for piglets resting place floor heating from May till the middle of November (2010) the economy was about Our experimental investigation has shown that using the worm air from a pigsty ventilation system for evaporators warming, the heat pump operation is possible even at negative outside temperature. Acknowledgment Research is completed by financial support of European Structural Fund: Attraction of human resources for investigation of renewable energy resources. Realized by the Project Department of the Latvia University of Agriculture (contract no. 2009/0225/1DP/ /09/APIA/VIAA/129). References 1. Blumberga D. Heat pump. R.: RTU p. (in Latvian). 2. Reay D., Macmichael D. Heat Pumps. M.: Energoizdat p. (in Russian) (in Latvian). 4. Ilsters A., Ziemelis I., Zagorska V. Warming of Piglets Resting Places by Air Heat Pump in Dependence on Outside Air Temperature. Proceedings of the 9 th International Scientific Conference Engineering for Rural Development, Jelgava, Latvia, 2010, pp
Exploitation Tests of Borehole Heat Exchangers in the Laboratory of Renewable Energy Sources in Miekinia Poland
Proceedings World Geothermal Congress 2015 Melbourne, Australia, 19-25 April 2015 Exploitation Tests of Borehole Heat Exchangers in the Laboratory of Renewable Energy Sources in Miekinia Poland Jaroslaw
CALCULATION OF ENERGY PRODUCED BY SOLAR COLLECTORS
CALCULATION OF ENERGY PRODUCED BY SOLAR COLLECTORS Imants Ziemelis, Liene Kancevica, Zanis Jesko, Henriks Putans Latvia University of Agriculture, Research Institute of Agricultural Machinery [email protected],
Energy consumption and heat recovery of refrigeration system in modern Arena
Energy consumption and heat recovery of refrigeration system in modern Arena By Alexander Cohr Pachai Johnson Controls Building Efficiency Christian X s Vej 201 8270 Hoejbjerg Denmark [email protected]
Daikin Altherma Hybrid Heat Pump
your comfort. our world. Daikin Altherma Hybrid Heat Pump Smart heating technology for the best of both worlds Heating Integrated Solutions Ventilation Air Conditioning Refrigeration Forward thinking About
Daikin Altherma Hybrid Heat Pump
Daikin Altherma Hybrid Heat Pump Smart technology for the best of both worlds NATIONAL HEAT PUMP 19 JUNE 2014 ICC BIRMINGHAM WINNER Forward thinking Now is the time to rethink the way we heat our homes
Performance Evaluation of a Heat Pump System for Simultaneous Heating and Cooling
for Simultaneous Heating and Cooling F. Sustainable Energy Centre, University of South Australia Mawson Lakes Boulevard, Mawson Lakes 5095 AUSTRALIA E-mail: [email protected] Abstract The high efficiency
Sea Water Heat Pump Project
Sea Water Heat Pump Project Alaska SeaLife Center, Seward, AK Presenter: Andy Baker, PE, YourCleanEnergy LLC Also Present is ASLC Operations Manager: Darryl Schaefermeyer ACEP Rural Energy Conference Forum
The function of a power station is to deliver
CHAPTER CHAPTER 3 Variable Load on Power Stations 3.1 Structure of Electric Power System 3.2 Variable Load on Power Station 3.3 Load Curves 3.4 Important Terms and Factors 3.5 Units Generated per Annum
New technical solutions for energy efficient buildings
- New technical solutions for energy efficient buildings State of the Art Report New technologies for heat pumps Authors: Heimo Staller, Angelika Tisch, IFZ Oct. 2010 Background Heat pumps are machines
Natural geothermal energy.
ROTEX ground source heat pump Natural geothermal energy. ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient.
RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary
RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary January 2013 TABLE OF CONTENTS INTRODUCTION... 3 GENERAL RECOMMENDATIONS... 3 Communication with customers in the field of environmental sustainability...
Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"
Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A" Takahiro OUE *1, Kazuto OKADA *1 *1 Refrigeration System & Energy Dept., Compressor Div., Machinery Business Kobe Steel has developed an air-sourced
Daikin Altherma hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient
Zhao et al. 2.2 Experimental Results in Winter Season The analysis given below was based on the data collected from Nov. 2003 to Mar. 15, 2004.
Proceedings World Geothermal Congress 2005 Antalya, Turkey, 24-29 April 2005 A Case Study of Ground Source Heat Pump System in China Jun Zhao, Chuanshan Dai, Xinguo Li, Qiang Zhu and Lixin Li College of
Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets
2 Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets - Extending Use of New Heat Pump System in Cold Regions
Hybrid heat pumps. saving energy and reducing carbon emissions
Hybrid heat pumps saving energy and reducing carbon emissions Bart Aspeslagh Product planning and new technology manager, Daikin Europe NV. [email protected] Stefanie Debaets Design engineer,
Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment
Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment The heating, ventilation and cooling loads of typical commercial office space can range
Yijun Gao, Wei Wu, Zongwei Han, Xianting Li *
Study on the performance of air conditioning system combining heat pipe and vapor compression based on ground source energy-bus for commercial buildings in north China Yijun Gao, Wei Wu, Zongwei Han, Xianting
Energy audit in Finland
Energy audit in Finland NorTech Oulu Lauri Mikkonen Energy Audit in Finland An energy audit tells about the energy efficiency and total energy consumption in a building, including all consumed heating,
HEATING, VENTILATION & AIR CONDITIONING
HEATING, VENTILATION & AIR CONDITIONING as part of the Energy Efficiency Information Grants Program Heating and cooling can account for approximately 23 % of energy use in pubs and hotels 1. Reducing heating
HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS
HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS INTRODUCTION 1. There are no general EU regulations and standards for outdoor swimming pool heating. Local regulations in the member countries are covering most
Rainwater Harvesting
Rainwater Harvesting With climate change now a reality rather than a speculated possibility, the demand on water resources has gone up, whilst the amount of water available for supply has gone down. Forth
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
Federation of European Heating, Ventilation and Air-conditioning Associations
Federation of European Heating, Ventilation and Air-conditioning Associations Address: Rue Washington 40 1050 Brussels Belgium www.rehva.eu [email protected] Tel: +32 2 514 11 71 Fax: +32 2 512 90 62 REHVA
The natural ombination
The natural ombination DAIKIN ALTHERMA HYBRID HEAT PUMP 2 A new pportunity in residential heating! There is a growing demand from home owners to replace heating systems, especially replacing of gas boilers,
The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.
MSV: Square Footage: 24,844 No. of Floors: 1 Year Built: 1963 Type of Use: Lounge and dining area open all night for snacks Steam Water-cooled condenser, 50-Ton York unit with a 6 cylinder-reciprocating
HEAT PUMPS A KEY COMPONENT IN LOW CARBON FUTURE
HEAT PUMPS A KEY COMPONENT IN LOW CARBON FUTURE Satish Joshi Managing Director CONTENTS 1. INTRODUCTION, APPLICATIONS 2. TECHNOLOGY, PROJECTS DONE, COST COMPARISION 3. HEAT PUMPS IN THE RENEWABLES DIRECTIVE,
THE TRACKING SYSTEM FOR SOLAR COLLECTORS WITH REFLECTORS
THE TRACKING SYSTEM FOR SOLAR COLLECTORS WITH REFLECTORS Liene Kancevica, Henriks Putans, Imants Ziemelis Latvia University of Agriculture, Research Institute of Agricultural Machinery [email protected],
ENERGY SAVING WORT BOILING SISTEM IN BREWING FACTORY
ENERGY SAVING WORT BOILING SISTEM IN BREWING FACTORY Mariana Geta TOMESCU (cas. Cismarescu) *, Carol CSATLOS** * Faculty of Food and Tourism, Transilvania University of Braşov, Braşov, Romania ** Faculty
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries
Study on Performance Evaluation of a Split Air Conditioning System Under the Actual Conditions
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Study on Performance Evaluation of a Split Air Conditioning System Under
Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...
Solar air collectors for industry and larger halls N S Ø Efficient dehumidification and air heating for free... This booklet contains information about SolarVenti Industrial air solar system. The system
RESEARCH HIGHLIGHT. Performance Assessment of a Cold-Climate Air Source Heat Pump
RESEARCH HIGHLIGHT December 2014 Technical Series 14-102 Performance Assessment of a Cold-Climate Air Source Heat Pump INTRODUCTION Most Canadians are familiar with air source heat pump technology in the
Daikin Altherma. hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Why choose Daikin? As an industry leader, Daikin combines broad experience, technical innovation and responsive customer service to help you meet
Design and Re-Use Of Shovadans In Today's Architecture "With Due Attention To Have Thermal Energy Of The Earth"
RESEARCH INVENTY: International Journal of Engineering and Science ISBN: 2319-6483, ISSN: 2278-4721, Vol. 1, Issue 8 (November 2012), PP 60-64 www.researchinventy.com Design and Re-Use Of Shovadans In
ROTEX gas hybrid heat pump. A strong team.
ROTEX gas hybrid heat pump A strong team. The new ROTEX HPU hybrid gas hybrid heat pump always selects the most favourable heating mode automatically. For a long time the general opinion was that a heat
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
How Ground/Water Source Heat Pumps Work
How Ground/Water Source s Work Steve Kavanaugh, Professor Emeritus of Mechanical Engineering, University of Alabama Ground Source s (a.k.a. Geothermal s) are becoming more common as the costs of energy
ENERGY PRODUCING SYSTEMS
ENERGY PRODUCING SYSTEMS SOLAR POWER INTRODUCTION Energy from the sun falls on our planet on a daily basis. The warmth of the sun creates conditions on earth conducive to life. The weather patterns that
Ecodan Air Source Heat Pump and Flow Temperature Controller 2
HOMEOWNER STANDALONE Homeowner Information SEPTEMBER 2011 Ecodan Air Source Heat Pump and Flow Temperature Controller 2 Ecodan Air Source Heat Pump Model Number PUHZ-W50VHA(2)-BS PUHZ-W85VHA(2)-BS PUHZ-HW140VHA(2)-BS
Heat Pumps for Swimming Pools
Page 1 of 5 Heat Pumps for Swimming Pools This factsheet provides members with invaluable information about heat pumps and their use for heating swimming pool water. There is a consumer factsheet already
Daikin Altherma Hybrid Heat Pump
your comfort. our world. Daikin Altherma Hybrid Heat Pump The natural combination Heating Integrated Solutions Ventilation Air Conditioning Refrigeration About Daikin Forward thinking... Daikin has a worldwide
SEERS International. Hybrid Hot Water Systems. Innovation Technology
SEERS International Hybrid Hot Water Systems Innovation Technology EFFECTS OF GLOBAL WARMING Invented & Manufactured By : Seers International Patent Number: PI-20082195 5 th Generation Hybrid Hot Water
Dehumidifier D 850E. - Instruction manual version 02
Dehumidifier D 850E - Instruction manual version 02 Content 1. Description of dehumidifier 1.1. General data 1.2. Technical data 2. Operation and usage 2.1. Usage 2.2. Location and installation 2.3. Preparing
Best Practice Guide BPGCS007
Best Practice Guide BPGCS007 ENERGY MANAGEMENT Introduction: With rising fuel costs, opening of electricity and gas markets to alternate suppliers and climate change, the requirement to monitor and reduce
How to choose a heat pump and use it wisely
How to choose a heat pump and use it wisely Contents How does a heat pump work? 2 Insulating your home 3 Heat loss in the home Not all heat pumps are created equal 4 Choosing a heat pump 4 Choosing by
Crowne Plaza Copenhagen Towers The world s greenest hotel
Crowne Plaza Copenhagen Towers The world s greenest hotel The new Crowne Plaza Copenhagen Towers in Copenhagen, has been designed with sustainability in top of mind. The hotel is one of the first hotels
A Class Air Source Heat Pump User Guide
A Class Air Source Heat Pump User Guide IMPORTANT THIS MANUAL MUST BE LEFT WITH THE USER AFTER INSTALLATION 8/60476/0 Issue 1.03 Contents 1: Introduction 1 2: How the Heat Pump Works 1 2.1 Tips and advice
HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.
HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET. AFFORDABLE SOLUTIONS FROM AMERISTAR. We know that heating and cooling systems can be a major investment for homeowners. Our goal is
Standards & Labeling System for Air-conditioning Equipment in US, Europe and Japan
Standards & Labeling System for Air-conditioning Equipment in US, Europe and Japan The Japan Refrigeration and Air Conditioning Industry Association (JRAIA) Tetsuro Kishimoto, President Sugawara Sakuo,
Integrated Solar Radiant Systems
Integrated Solar Radiant Systems William Shady PE President Topics Radiant heating Indoor air quality Radiant Cooling Project Photos Questions and answers The goal for our clients Healthy Comfort Why Radiant
Commercial Energy Savings Guide. www.touchstoneenergy.coop
Commercial Energy Savings Guide www.touchstoneenergy.coop NRECA Pocket Savings Guide Pag.indd 1-3 2/7/05 4:19:07 PM Commercial Energy Saving Tips Notes: This guide provides basic hints on ways to reduce
ALONE. small scale solar cooling device Project No TREN FP7EN 218952. Project No TREN/FP7EN/218952 ALONE. small scale solar cooling device
Project No TREN/FP7EN/218952 ALONE small scale solar cooling device Collaborative Project Small or Medium-scale Focused Research Project DELIVERABLE D5.2 Start date of the project: October 2008, Duration:
HEATER, AIR CONDITIONING AND VENTILATION
55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT
Energy Saving Tips. They can have a dramatic impact on your bill. The cheapest energy is the energy you don t use.
Energy Saving Tips They can have a dramatic impact on your bill. The cheapest energy is the energy you don t use. Drive by your building at night. Driving by your building at night makes it easy to check
REDUCING ENERGY CONSUMPTION AND PEAK POWER IN BELGIUM
REDUCING ENERGY CONSUMPTION AND PEAK POWER IN BELGIUM With the support of: [email protected] www.3e.eu PRESENTATION CONTENT Outline Objective Background Energy efficiency: examples in 3 sectors Residential: electric
Regency TAFE, SA. An evaluation of the effects of PermaFrost treatment on a Fujitsu Heat Pump. July 2008. Prepared by
Regency TAFE, SA An evaluation of the effects of PermaFrost treatment on a Fujitsu Heat Pump July 2008 Prepared by Andrew Pang Andrew Pang & Associates Pty Ltd Phone: 0438 188 180 Facsimile: 9331 0898
ENERGY AUDITS IN DWELLING BUILDINGS IN LATVIA. DATA ANALYSIS
ENERGY AUDITS IN DWELLING BUILDINGS IN LATVIA. DATA ANALYSIS SUMMARY D. BLUMBERGA*, A. BLUMBERGA, V. VITOLINS Riga Technical University Kronvalda bulvaris 1, LV1010, Riga, Latvia [email protected] Tel.: +
Solar systems provide a range of flexible heating
f a c t s h e e t 7 Solar Power Production photo by Alex Nikada Why solar? Solar systems provide a range of flexible heating and electricity options and are particularly wellsuited to remote or off-grid
International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS
International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES
PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING
PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING LI CHUNYING DOCTOR OF PHILOSOPHY CITY UNIVERSITY OF HONG KONG FEBRUARY 2012 CITY UNIVERSITY OF HONG KONG 香 港 城 市 大 學 Performance Evaluation of Water-flow
Factory owners must ensure the boiler is:
Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised
Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold
Bradlee Boilers Ltd Instruction Manual for starting up Bradlee Hire Boiler from Cold To be read in conjunction with Bradlee Boiler guide to Commissioning Boilers Document Ref: HM001 1. Ensure that all
DataCenter 2020: first results for energy-optimization at existing data centers
DataCenter : first results for energy-optimization at existing data centers July Powered by WHITE PAPER: DataCenter DataCenter : first results for energy-optimization at existing data centers Introduction
Catalyst RTU Controller Study Report
Catalyst RTU Controller Study Report Sacramento Municipal Utility District December 15, 2014 Prepared by: Daniel J. Chapmand, ADM and Bruce Baccei, SMUD Project # ET13SMUD1037 The information in this report
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The
Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions
Free Cooling in Data Centers John Speck, RCDD, DCDC JFC Solutions Why this topic Many data center projects or retrofits do not have a comprehensive analyses of systems power consumption completed in the
Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now
Fact Sheet #6 Air Conditioning In this fact sheet you will discover: The opportunity for energy efficiency How air conditioning works Low cost actions to reduce energy usage now Investments to reduce costs
Ambient Temperature Operation and Matching MAN B&W Two-stroke Engines
Ambient Temperature Operation and Matching MAN B&W Two-stroke Engines Content Introduction...5 Standard ambient matched engine...5 Operating at high seawater with standard matched engine...6 Non-standard
Adaptive strategies for office spaces in the UK climate
International Conference Passive and Low Energy Cooling 631 Adaptive strategies for office spaces in the UK climate I. Gallou Environment & Energy Studies Programme, Architectural Association Graduate
Creating Efficient HVAC Systems
Creating Efficient HVAC Systems Heating and Cooling Fundamentals for Commercial Buildings Heating, ventilating, and air conditioning (HVAC) systems account for nearly half of the energy used in a typical
steinecker Stromboli wort boiling system Perfect in every brewing process
wort boiling system Perfect in every brewing process Perfect for wort quality and saving resources Wort boiling is a fundamental step in the production of premium-quality beer. A stable head on the beer
PTAC Selection Guide. Optimize your spend with the right PTAC equipment!
PTAC Selection Guide Optimize your spend with the right PTAC equipment! The Direct Supply Difference Direct Supply Equipment & Furnishings understands the challenges of securing equipment for your communities.
MONITORING SCHOOL ENERGY CONSUMPTION
MONITORING SCHOOL ENERGY CONSUMPTION Goal(s): The mains goal of the energy monitoring activity are: To make the pupils and all school staff aware of school energy consumption; and To show how changes in
HIGH-EFFICIENCY CO 2 HEAT PUMP WATER HEATER SYSTEMS FOR RESIDENTIAL AND NON-RESIDENTIAL BUILDINGS
1 HIGH-EFFICIENCY CO 2 HEAT PUMP WATER HEATER SYSTEMS FOR RESIDENTIAL AND NON-RESIDENTIAL BUILDINGS Jørn Stene SINTEF Energy Research, 7465 Trondheim, Norway [email protected] In hotels, hospitals,
Variable Capacity Compressors, a new dimension for refrigeration engineers to explore
Variable Capacity Compressors, a new dimension for refrigeration engineers to explore By: Marcos G. Schwarz, VCC Group Leader Corporate Research & Development, EMBRACO SA Abstract: This paper presents
GETTING STARTED WITH THE MIPOWER MANAGEMENT SYSTEM
GETTING STARTED WITH THE MIPOWER MANAGEMENT SYSTEM This Quick Start guide will help you start using the MiPower Management System provided by Grayson Collin Electric Cooperative. You should create your
Analysis of data centre cooling energy efficiency
Analysis of data centre cooling energy efficiency An analysis of the distribution of energy overheads in the data centre and the relationship between economiser hours and chiller efficiency Liam Newcombe
Resources for School Energy Managers
Resources for School Energy Managers Cooling can present a substantial energy cost to schools. Temperatures of 24 to 27 C with less than 60% relative humidity give acceptable comfort in summer. Higher
Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro
Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro Dept. Building Environment Science &Technologies Politecnico di Milano Italy Research funded
Waste Heat Recovery through Air Conditioning System
International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn : 2278-800X, www.ijerd.com Volume 5, Issue 3 (December 2012), PP. 87-92 Waste Heat Recovery through Air Conditioning
How To Improve Energy Efficiency Through Raising Inlet Temperatures
Data Center Operating Cost Savings Realized by Air Flow Management and Increased Rack Inlet Temperatures William Seeber Stephen Seeber Mid Atlantic Infrared Services, Inc. 5309 Mohican Road Bethesda, MD
Heating & Cooling Efficiency
Heating & Cooling Efficiency Advantages of Geothermal HVAC Efficiency Keith Swilley Gulf Power Company Why Gulf Power Promotes Energy Efficiency? Customer Satisfaction Education Help Customers Make Smart
Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2008 Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications
High-efficient gas boiler CompactGas
High-efficient gas boiler CompactGas Patented alufer for a high efficiency and low emission. 1 CompactGas (1000-2800). Advantages at a glance. The Hoval CompactGas fulfils all expectations with regard
Clean & Clever Energy Toolkits Hot Water System
Clean & Clever Energy Toolkits Hot Water System Acknowledgement This Activity received funding from the Department of Industry as part of the Energy Efficiency Information Grants Program. Disclaimer The
Direct Fresh Air Free Cooling of Data Centres
White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The
warm air for the healthiest, most comfortable home environment possible. This occurs with a system efficiency of up to 90%.
Lifebreath delivers a complete indoor climate control package Indoor comfort in a small package The patented Lifebreath Clean Air Furnace combines the fresh air benefits of the Heat Recovery Ventilator
OPTIMAL POLYGEN COOLING CONCEPT FOR ST. OLAVS HOSPITAL IN TRONDHEIM, NORWAY
1st European Conference on Polygeneration OPTIMAL POLYGEN COOLING CONCEPT FOR ST. OLAVS HOSPITAL IN TRONDHEIM, NORWAY G. Eggen 1, A. Utne 2 1) COWI A/S, PB 2564 Sentrum, NO-7414 Trondheim, Norway, e-mail:
HP switch LP switch Discharge thermo Comp. Surface thermo
1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer
Retail Tariffs. Business, Irrigation and Farming Tariffs
Retail Tariffs Business, Irrigation and Farming Tariffs Background on Ergon Energy Qld Retail Tariffs The Queensland Competition Authority (QCA) has been delegated the task of determining notified prices
Heat Recovery from Data Centers. Guided Tour in Kista, January 21, 2015
Heat Recovery from Data Centers Guided Tour in Kista, January 21, 2015 Welcome! The purpose of this tour is to show you large scale heat recovery in practice! We will take you through Kista Science City
A heat pump system with a latent heat storage utilizing seawater installed in an aquarium
Energy and Buildings xxx (2005) xxx xxx www.elsevier.com/locate/enbuild A heat pump system with a latent heat storage utilizing seawater installed in an aquarium Satoru Okamoto * Department of Mathematics
District heating and district cooling with large centrifugal chiller - heat pumps
10th International Symposium on District Heating and Cooling September 3-5, 2006 Tuesday, 5 September 2006 Sektion 5 a Renewable energy and district heating District heating and district cooling with large
LG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,