1 Instructions - Parts List T1 2:1 Ratio Transfer Pump N EN For use with polyurethane foam, polyurea, and solvent-borne and water-borne materials. For professional use only. Model Gallon (200 Liter) Drum Size 180 psi (1.2 MPa, 12 bar) Maximum Air Working Pressure 360 psi (2.5 MPa, 25 bar) Maximum Fluid Working Pressure Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. TI17170a 0359 II 1/2 G T6 ITS03ATEX11227
2 Contents Warnings Isocyanate Hazard Moisture Sensitivity of Isocyanates Foam Self-Ignition Keep Components A and B Separate Changing Materials Typical Installation Typical Installation without Circulation Typical Installation with Circulation Typical Installation for Lubrication Applications. 9 Installation System Accessories Air Line Accessories Fluid Line Accessories Setup Grounding Operation Pressure Relief Procedure Flush Pump Before Use Flushing Daily Startup Daily Shutdown Repair Before you start Air Motor Disassembly Air Motor Reassembly Pump Lower Disassembly Pump Lower Reassembly Troubleshooting Parts Accessories Dimensions Technical Data Performance Chart Graco Standard Warranty Graco Information N
3 Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable. WARNING TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. Read MSDS s to know the specific hazards of the fluids you are using. Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines. Always wear impervious gloves when spraying or cleaning equipment. PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to: Protective eyewear Clothing and respirator as recommended by the fluid and solvent manufacturer Gloves Hearing protection FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: Use equipment only in well ventilated area. Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc). Keep work area free of debris, including solvent, rags and gasoline. Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present. Ground all equipment in the work area. See Grounding instructions. Use only grounded hoses. Hold gun firmly to side of grounded pail when triggering into pail. If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem. Keep a working fire extinguisher in the work area N 3
4 Warnings WARNING EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. Do not operate the unit when fatigued or under the influence of drugs or alcohol. Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer s warnings. For complete information about your material, request MSDS forms from distributor or retailer. Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer s replacement parts only. Do not alter or modify equipment. Use equipment only for its intended purpose. Call your distributor for information. Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not kink or over bend hoses or use hoses to pull equipment. Keep children and animals away from work area. Comply with all applicable safety regulations. PRESSURIZED EQUIPMENT HAZARD Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury. Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment. Tighten all fluid connections before operating the equipment. Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. MOVING PARTS HAZARD Moving parts can pinch or amputate fingers and other body parts. Keep clear of moving parts. Do not operate equipment with protective guards or covers removed. Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure in this manual. Disconnect power or air supply N
5 Isocyanate Hazard Isocyanate Hazard To prevent exposing ISO to moisture: Spraying materials containing isocyanates creates potentially harmful mists, vapors, and atomized particulates. Read material manufacturer s warnings and material MSDS to know specific hazards and precautions related to isocyanates. Prevent inhalation of isocyanate mists, vapors, and atomized particulates by providing sufficient ventilation in the work area. If sufficient ventilation is not available, a supplied-air respirator is required for everyone in the work area. To prevent contact with isocyanates, appropriate personal protective equipment, including chemically impermeable gloves, boots, aprons, and goggles, is also required for everyone in the work area. Always use a sealed container with a desiccant dryer in the vent, or a nitrogen atmosphere. Never store ISO in an open container. Use moisture-proof hoses specifically designed for ISO, such as those supplied with your system. Never use reclaimed solvents, which may contain moisture. Always keep solvent containers closed when not in use. Never use solvent on one side if it has been contaminated from the other side. Always lubricate threaded parts with Part ISO pump oil or grease when reassembling. Moisture Sensitivity of Isocyanates Isocyanates (ISO) are catalysts used in two component foam and polyurea coatings. ISO will react with moisture (such as humidity) to form small, hard, abrasive crystals, which become suspended in the fluid. Eventually a film will form on the surface and the ISO will begin to gel, increasing in viscosity. If used, this partially cured ISO will reduce performance and the life of all wetted parts. The amount of film formation and rate of crystallization varies depending on the blend of ISO, the humidity, and the temperature N 5
6 Isocyanate Hazard Foam Self-Ignition Some materials may become self-igniting if applied too thick. Read material manufacturer s warnings and material MSDS. Keep Components A and B Separate CAUTION To prevent cross-contamination of the equipment s wetted parts, never interchange component A and component B. Changing Materials When changing materials, flush the equipment multiple times to ensure it is thoroughly clean. Check with your material manufacturer for chemical compatibility. Some materials use catalyst on the A side, but some applications may use catalyst on the B side. Epoxies often have amines on the B (catalyst) side. Polyurethanes often have amines on the B (resin) side N
7 Typical Installation Typical Installation Typical Installation without Circulation Key for FIG. 1. A Reactor Proportioner B Heated Hose C Fluid Temperature Sensor (FTS) D Heated Whip Hose E Fusion Spray Gun F Proportioner and Gun Air Supply Hose G Feed Pump Air Supply Lines 3/8 in. (76 mm) ID min. H Waste Containers J Fluid Supply Lines (217382) K Feed Pumps L Agitator M Desiccant Dryer N Bleed Lines/Over Pressure Relief P Gun Fluid Manifold K G M K A N F J D E L H P C* B FIG. 1: Typical Installation without Circulation ti11572a * Shown exposed for clarity. Wrap with tape during operation N 7
8 Typical Installation Typical Installation with Circulation Key for FIG. 2. A Reactor Proportioner B Heated Hose C Fluid Temperature Sensor (FTS) D Heated Whip Hose E Fusion Spray Gun F Proportioner and Gun Air Supply Hose G Feed Pump Air Supply Lines 3/8 in. (76 mm) ID min. J Fluid Supply Lines (217382) K Feed Pumps L Agitator M Desiccant Dryer N Bleed Lines/Over Pressure Relief P Gun Fluid Manifold K G M K A N F J D E L P N C* B ti11571a FIG. 2: Typical Installation with Circulation * Shown exposed for clarity. Wrap with tape during operation N
9 Typical Installation Typical Installation for Lubrication Applications Key for FIG. 3. AA Pump Air Regulator AB Air Line Lubricator AC Air Line Filter AD Bleed-Type Master Air Valve (required, for pump) AE Fluid Drain Valve (required) AF AG AH AJ AK AL AM Bung Adapter Grounded Air Hose Grounded Fluid Hose Pump Fluid Inlet 1/4 npt(f) Pump Air Inlet 1/2 npt(f) Pump Fluid Outlet Return Port AG AK AD AC AA AD AB AM AL AH AE AF ti11573a FIG. 3: Typical Installation for Lubrication Applications AJ N 9
10 Installation Installation A bleed-type master air valve (AD) and a fluid drain valve (AE) are required in your system, to help reduce the risk of serious injury, including splashing fluid in the eyes or on the skin, and injury from moving parts when you are adjusting or repairing the pump. The bleed-type master air valve (AD) relieves air trapped between this valve and the pump after the pump is shut off. Trapped air can cause the pump to cycle unexpectedly and result in serious injury, including amputation. Install the valve close to the pump. The fluid drain valve (AE) helps relieve pressure in the displacement pump, hose, and dispensing valve when shutting off the pump. Actuating the dispensing valve to relieve pressure may not be sufficient, especially if there is a clog in the hose or the dispensing valve. A bleed-type master air valve (AD) is required in your system to relieve air trapped between it and the air motor when the valve is closed (see the WARNING on left). Be sure the bleed valve is easily accessible from the pump, and is located downstream from the air regulator. An air line filter (AC) to remove harmful dirt and moisture from the compressed air supply. A second bleed-type air valve (AD) isolates the air line accessories for servicing. Locate upstream from all other air line accessories. Fluid Line Accessories A fluid drain valve (AE) is required in your system to relieve fluid pressure in the hose and gun (see the WARNING on left). Install the drain valve so that it points down and the handle points up when the valve is opened. System Accessories Refer to FIG. 3 and the Accessories on page 24. To ensure maximum pump performance, be sure that all accessories used are properly sized to meet your system s requirements. Air Line Accessories Install the following accessories in the order shown in the Typical Installation for Lubrication Applications, using adapters as necessary: An air line lubricator (AB) provides automatic air motor lubrication N
11 Setup Setup 1. Apply thread sealant to the male threads of the air needle valve (54) and the quick disconnect fitting (55). Install into inlet port (AK). 3. Use labels (25) provided to identify the appropriate pump for your material. 1 Apply thread sealant FIG. 6 ti11649a FIG AK TI17171a 2. Apply thread sealant to the male outlet fitting (BC) (not supplied) and insert into the outlet port (AL). 4. Lubricate the bung adapter (16) inside diameter and mounting threads. Ensure the gasket is in place and screw the bung adapter (16) securely into the bunghole of the drum. Insert the pump through the adapter (16) and lock it in place. 1 Apply thread sealant 16 AL 1 BC TI17173a FIG. 7 FIG. 5 TI17172a N 11
12 Setup 5. Install air line (3/8 in. (76 mm) ID minimum) with quick disconnect air coupler (56). end of the wire to a true earth ground. Make certain to comply with all National, State, and Local Electrical Codes. 56 Y 2 AL 24 AH AM FIG. 9 TI17175a FIG Connect a grounded fluid hose (AH) to the 1/2 npt(f) fluid outlet (AL). In a circulating system, remove the pipe plug (2) and connect a fluid return line to the 3/8 npt(f) return port (AM). Grounding TI17174a 2. Air compressor: according to manufacturer s recommendations. 3. Fluid hoses: use only grounded hoses with a maximum of 300 ft (91 m) combined hose length to ensure grounding continuity. 4. Dispensing valve: grounding is obtained through connection to a properly grounded fluid hose and pump. 5. Object being sprayed: according to local code. 6. Fluid supply container: according to local code. To reduce the risk of static sparking, ground the pump and all other equipment used or located in the pumping area. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Ground all of this equipment. 1. Pump: Connect Ground Wire (Y) to grounding screw (24) and tighten the screw securely. See FIG. 9. Connect the other 7. All solvent pails used when flushing, according to local code. Use only metal pails, which are conductive. Do not place the pail on a non conductive surface, such as paper or cardboard, which interrupts the grounding continuity. 8. To maintain grounding continuity when flushing or relieving pressure, always hold a metal part of the spray gun/dispensing valve firmly to the side of a grounded metal pail, then trigger the gun/valve N
13 Operation Operation Pressure Relief Procedure Flushing Flush at the lowest pressure possible. Check connectors for leaks and tighten as necessary. Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury from splashing or moving parts. Flush with a fluid that is compatible with the fluid being dispensed and the equipment wetted parts. 1. Shut off the air to the pump. 2. Close the bleed-type master air valve (AD). 3. Hold a metal part of the dispense valve firmly to a grounded metal pail. Trigger the valve to relieve pressure. 4. Open all fluid drain valves in the system, having a waste container ready to catch drainage. Leave drain valve(s) open until you are ready to dispense again. 5. If you suspect the nozzle or hose is clogged or that pressure has not been fully relieved after following the steps above, VERY SLOWLY loosen the hose end coupling to relieve pressure gradually, then loosen completely. Clear hose or nozzle obstruction. Flush Pump Before Use The pump is tested with lightweight oil, which is left in to protect the pump parts. To prevent contamination of the fluid you are pumping, flush the pump with a compatible solvent before using it. See Flushing, page 13. Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury from splashing or moving parts. 1. Follow Pressure Relief Procedure, page Place suction tube in grounded metal drum containing cleaning fluid. 3. Set pump to lowest possible fluid pressure, and start pump. 4. Hold a metal part of the dispense valve firmly to a grounded metal pail. Trigger the dispense valve until clean solvent dispenses. 5. Remove valve from hose. 6. Follow Pressure Relief Procedure, and remove fluid filter and soak in solvent. Replace filter cap. 7. Cycle the pump slowly for at least 5 minutes, then stop and disconnect the air hose. 8. Push up on the ball (5) of the intake valve (29) to drain the lower part of the pump. 9. Turn the pump over to drain the upper part of the pump N 13
14 Operation Daily Startup 1. Verify that the air needle valve (54) is closed. 2. Connect the air line quick disconnect coupler (55) to the transfer pump. 3. Turn on the main air supply. 4. Slowly open the air needle valve until the transfer pump runs slowly. 5. Use the air needle valve to control the pump speed. Caution Never allow the pump to run dry. A dry pump will quickly accelerate to a high speed and can damage the pump. If the pump accelerates quickly or starts running too fast, stop it immediately and check the fluid supply. If the supply container is empty or air has been pumped into the lines, refill the container; prime the pump and the lines with fluid, or flush and leave it filled with a compatible solvent. Be sure to eliminate all air from the fluid system. Corrosion Protection for Pump Caution Water or moist air can cause your pump to corrode. To help prevent corrosion, NEVER leave the pump filled with water or air. After normal flushing, flush the pump again with mineral spirits solvent (also called white spirit) or oil-based solvent, relieve pressure, and leave the mineral spirits solvent (also called white spirit) in the pump. Be sure to follow to the Pressure Relief Procedure on page 13. Lubrication If you are not using an accessory air line lubricator, manually lubricate the motor daily. Disconnect the air regulator, place about 15 drops of light machine oil in the pump air inlet, reconnect the regulator and turn on the air supply to dispense oil into the motor. Do not attempt to operate pump unless it is securely mounted in a drum. Daily Shutdown 1. Disconnect the air line quick disconnect coupler (55). 2. When air pressure is bled off, close the air needle valve (54) N
15 Repair Repair Air Motor Disassembly Before you start Have all the necessary repair parts on hand. Clean all parts with a compatible solvent. Inspect parts for wear or damage and replace as needed. Flush the pump, if possible. Stop the pump at the bottom of its stroke. Follow Pressure Relief Procedure on page 13 before repairing any part of the system. Disconnect the air and the fluid hoses and the grounding wire. Remove the pump from its mounting and clamp it in a vise. To reduce the risk of injury when servicing the air motor, always remove cylinder cap (34) from air cylinder (8) before removing air cylinder from base (13). 1. Unscrew the cylinder cap (34) from the cylinder (8). To remove the spring (7), pry gently under the coils in the direction of the helix. Inspect the spring (7) and gasket (27) for wear or damage; replace if necessary. See FIG Required Tools Pliers Set of socket wrenches Set of adjustable wrenches 8 13 Insert Tool 24B917 FIG. 10 TI17176a 2. Unscrew the cylinder (8) from the air motor base (13) and lift the cylinder straight off the air piston (38). Unscrew by hand or use a chain wrench to prevent distortion of the cylinder s shape. See FIG N 15
16 Repair 3. Use a pliers on the top plate of the air valve piston (38) and a wrench on the piston rod (35) to unscrew the air valve piston from the piston rod. See FIG Disconnect the piston rod (35) from the pump connecting rod (37) and pull the piston rod out of the air motor base (13). Remove o-ring (6). Inspect o-ring (6) and replace if necessary FIG. 11 ti11654a 9 4. Remove washer (10), lower spring (9), and gasket (27). Inspect for wear or damage and replace as necessary. See FIG If any valve plate spacers (38d) are damaged, replace all three to maintain the correct clearance between the valve plates (18a,18f) and the seats. See FIG Apply locking compound to threads. Torque to in-lb ( N m) 38a 38d 27 6 FIG. 13 Air Motor Reassembly TI17177a 1. Reinstall o-ring (6). Reconnect the piston rod (35) and the pump connecting rod (37). See FIG Reinstall the gasket (11), spring (9), and washer (10). Reassemble the piston (38). Apply thread sealant to the threads of the piston rod (35) and carefully screw the piston (38) onto the rod. See FIG. 11 and FIG. 13. FIG f When installed, there should be in. (0.8 mm) minimum clearance between the washer (10) and the shoulder of the piston rod (35) N
17 Repair 3. Reinstall the spring (7) and gasket (27) on the cylinder cap (34) and screw the cap onto the cylinder (8). Screw the cylinder into the air motor base (13). See FIG Unscrew the intake valve housing (29) from the piston cylinder (58). Disassemble intake valve. Pump Lower Disassembly 28 5 In mid-2013 the fluid section was upgraded to prevent threaded joints from loosening due to vibrations. Wrench flats were also added to improve serviceability. 58 Series A and B pumps can be upgraded with repair kit 24R989. FIG TI17179b 1. Unscrew the air motor connecting ring (15). Lay the pump on its side and rotate until the ball on the pump connecting rod (37) releases from the socket in the motor piston rod (35). Separate the motor from the displacement pump. 3. Unscrew the piston cylinder (58) from the pump frame (36) FIG. 14 TI17178b Support the Series A and B pump frame with a strap wrench. Series C pumps have wrench flats. To repair the air motor, see Air Motor Disassembly on page N 17
18 Repair 4. Push down on the pump connecting rod (37) until fluid piston assembly is clear of displacement pump frame (36). Pull the piston assembly and connecting rod out of the frame. Remove the bearing (31) and seal (51) from the frame. 5. Unscrew the piston body (23) from the piston valve housing on the fluid piston rod (19) TI17180b Support the Series A and B pump frame with a strap wrench. Series C pumps have wrench flats. FIG. 16 Scoring or irregular surfaces on the connecting rods (37, 19) or polished inner wall of the pump frame (36) and piston cylinder (58) can cause premature packing wear and leaking. To check these parts, rub a finger over the surface or hold the part up to the light at an angle. Replace if necessary. 23 FIG ti11660a 6. Unscrew the fluid piston rod (19) from the pump connecting rod (37). Remove the cup packing (17) and bearing (18) FIG D_no seal N
19 Repair Pump Lower Reassembly 1. Lubricate packing (17) and bearing (18) with no. 2 lithium-based grease. 2. Install the bearing (18), and cup packing (17) with the lips facing down on the pump connecting rod (37). See FIG Lubricate the piston seals (21) and bearing (22) with no. 2 lithium-based grease. Install one piston seal (21) with the lips facing down, bearing (22), and second piston seal (21) with lips facing up on the piston (23). Install the backup washer (20) with the grooves facing down. See FIG. 17 on page Place the ball (3) on top of the piston body (23) and screw the piston body and the fluid piston rod (19) together. Torque to ft-lb (41-48 N m). Screw the piston valve housing (29) onto the lower connecting rod (19). See FIG. 17 on page Install the seal (51), with the lips facing down, in the displacement pump frame (36), then install bearing (31). 36 Install seal (51) from the bottom of the pump frame (36) with insert tool 24B Use a turning motion to maneuver and install the pump connecting rod (37) and piston back into the pump frame (36). See FIG. 14 on page Install piston cylinder (58). a. For Series A and B Pumps: Support the pump frame (36) with a strap wrench. Lubricate o-ring (57) lightly with grease and apply loctite to threads of pump cylinder (58). Torque to ft-lbs ( N m) FIG. 20: Series A and B 36 TI21638b b. For Series C Pumps: Support the pump frame (36) with wrench flats. Lubricate o-ring (57) lightly with grease and apply loctite to threads of pump cylinder (58). Torque to ft-lbs (41-48 N m) TI17181a FIG. 19 TI21637a FIG. 21: Series C N 19
20 Repair 8. Install intake valve (29). a. For Series A and B Pumps: Apply thread locker to threads of intake valve (29). Torque to ft-lbs ( N m) FIG. 22: Series A and B 29 TI17179b b. For Series C Pumps: Lubricate o-ring (59) and install thread locking compound to threads of intake valve (29). Torque to ft-lbs (41-48 N m) FIG. 23: Series C 29 5 TI21636a N
21 Troubleshooting Troubleshooting Problem Cause Solution The pump fails to operate. Dirty or worn air motor. Clean, service. The pump operates, but the output is low on both strokes. The pump operates, but the output is low on the downstroke. The pump operates, but the output is low on the upstroke. Erratic or accelerated operation. Pump slowly moves after fluid shutoff in downstroke. Pump slowly moves after fluid shutoff in upstroke. Inadequate air supply or restricted lines. Closed or clogged air valves. Clogged fluid hose or valve. Worn or damaged valves or seals. Clogged fluid hose or valve. Low or empty fluid supply. Worn or damaged valves or seals. Held open or worn intake valve. Worn or damaged valves or seals. Held open or worn piston valve. Worn or damaged valves or seals. Low or empty fluid supply. Broken air motor compression spring. Clogged or dirty intake valve check ball. Worn or damaged valves or seats. Clogged or dirty lower piston ball or seat. Worn or damaged valves or seats. Clean lines or increase the air supply (see Technical Data). Open or clear the valves. Clear the hose or valves. Service the valves or seals. Clear the hose or valves. Refill the fluid supply and reprime the pump. Service the valves or seals. Clear or service the valve. Service the valves or seals. Clear or service the valve. Service the valves or seals. Refill the fluid supply and reprime the pump. Replace the spring. Clean ball and seat. Install repair kit. Clean ball and seat. Install repair kit N 21
22 Parts Parts T1 2:1 Ratio Transfer Pump, a b 38c 38 38d 38e 38f g (thick) 57 (medium) (thin) Torque to ft-lb (41-48 N m) Lips face down Lips face up Grooves face down 37 5 Use assembly tool 24B Thin, medium, and thick refers to the relative cross section thickness of the o-rings b 16d TI17182c 16c 16a (brown) N
23 Parts T1 2:1 Ratio Transfer Pump, Ref. Part Description Qty PLUG, pipe; SST BALL, bearing, upper BALL, bearing, lower O-RING SPRING, compression, tapered J673 CYLINDER, air SPRING, compression WASHER, valve J674 BASE, motor, air J675 HOUSING, connecting rod J676 RING, connecting ADAPTER, bung; SST (includes 1 16a-16g) 16a O-RING; inner 1 16b 24J526 ADAPTER 1 16c CLAMP, hopper 1 16d O-RING; O.D PACKING, cup; upper piston C799 BEARING, piston, upper ROD, piston, fluid RING, back-up SEAL, piston, lower BEARING, piston, lower PISTON SCREW, ground K008 LABEL, ID GASKET PIN, ball stop T262 HOUSING, valve, intake BEARING, connecting rod CAP, cylinder, air 1 Ref. Part Description Qty J678 ROD, piston K361 FRAME, pump ROD, pump, connector J679 PISTON, valve, air 1 38a PLATE, exhaust 1 38b PISTON 1 38c O-RING 1 38d SPACER 3 38e O-RING 3 38f PLATE, intake 1 38g SCREW, # TAG, instruction SEAL VALVE, needle FITTING, line, air COUPLER, line, air O-RING R988 CYLINDER, piston O-RING 1 Complete T1 pump repair kit 24X055 contains repair kits and 24K363. Parts included in repair kit Parts included in repair kit 24K363. Indicates parts not shown (shipped loose). Parts included in repair kit 24R989. See Pump Lower Disassembly, page 17, for instructions N 23
24 Accessories Accessories Grounding Clamp Part Description Qty CLAMP, ground 1 Part Description Qty LUBRICATOR, air line; 8 oz (0.24 liter) 1 bowl capacity; 1/2 npt(f) inlet and outlet Bleed-Type Master Air Valve 300 psi (2.1 MPa, 21 bar) Maximum Working Pressure Part Description Qty VALVE, ball, vented; 1/2 npt(m) inlet x 1/2 1 npt(f) outlet Air Line Filter and Regulator 180 psi (1.3 MPa, 13 bar) Maximum Working Pressure Part Description Qty FILTER, air; includes gauge and two 1/4 npt(m) outlet valves, 50 micron filter element with 100 mesh inlet strainer; 1/2 npt(f) inlet; flow rate is over 50 scfm (1.4 m 3 /min). 1 Air Line Filter 250 psi (1.7 MPa, 17.5 bar) Maximum Working Pressure Part Description Qty FILTER, air line; 1/2 npt(f) inlet and outlet 1 Air Line Lubricator 250 psi (1.7 MPa, 17.5 bar) Maximum Working Pressure N
25 Accessories Air Regulator and Gauge 300 psi (2.1 MPa, 21 bar) Maximum Working Pressure Part Description Qty REGULATOR, air; psi (0-14 bar) regulated pressure range; 3/8 npt(f) inlet and outlet 1 Fluid Pressure Regulator 250 psi (1.7 MPa, 17.5 bar) Maximum Working Pressure Part Description Qty REGULATOR, fluid; carbon steel; 0-60 psi 1 (0-4 bar) regulated fluid pressure range; 2 gpm (7.6 liter/min) maximum flow rate REGULATOR, fluid; stainless steel; psi (0.4-7 bar) regulated fluid pressure range; 3 gpm (11.3 liter/min) maximum flow rate 1 Fluid Drain Valve 500 psi (3.5 MPa, 35 bar) Maximum Working Pressure Part Description Qty VALVE, ball; 1/2 npt(m) x 3/8 npt(f); 1 for non-corrosive fluids; carbon steel and PTFE VALVE, ball; 3/8 npt(m) x 3/8 npt(f); for corrosive fluids; SST and PTFE 1 Fluid Filter psi (2.1 MPa, 21 bar) Maximum Working Pressure Part Description Qty FILTER, 30 mesh FILTER, 60 mesh FILTER, 100 mesh 1 Insert Tool 24B917 (4 in. long) UHMWPE Packing Conversion Kit, Part Description Qty PACKING, cup PACKING, cup BEARING, piston BEARING, piston MANUAL, instruction N 25
26 Dimensions Dimensions 1/4 npt(f) Air Inlet 1/2 npt(f) Fluid Outlet 33.7 in. (85.6 cm) 43.0 in. (109.2 cm) 51.5 in. (130.8 cm) TI17170a N
27 Technical Data Technical Data Pressure ratio :1 Maximum fluid working pressure psi (2.5 MPa, 25 bar) Maximum air inlet pressure psi (1.2 MPa, 12 bar) Pump cycles per 1 gallon (3.8 liters) Maximum recommended pump speed for 100 cycles per min (150 cycles per min continuous operation intermittent) Gallons (liters) per pump cycle (0.095) Air consumption See Performance Chart on page 28. Maximum ambient temperature F (50 C) Maximum fluid temperature F (82 C) Wetted parts Stainless Steel, PTFE, PEEK Fluid recirculation port /8 npt(f) Air inlet port /4 npt(f) Fluid outlet port 1/2 npt(f) Weight 18.5 lbs. (8.4 kg) Sound Pressure 88.7 db(a) at 80 psi (0.55 MPa, 5.5 bar) Sound Power, per ISO db(a) at 80 psi (0.55 MPa, 5.5 bar) N 27
28 Technical Data Performance Chart Calculate Fluid Outlet Pressure (black curves) To calculate fluid outlet pressure (MPa/bar/psi) at a specific fluid flow (lpm/gpm) and operating air pressure (MPa/bar/psi), use the following instructions and pump data chart. 1. Locate desired fluid flow along bottom of chart. 2. Follow vertical line up to intersection with selected air pressure curve (black). Follow horizontally left to read fluid outlet pressure. Calculate Pump Air Consumption (gray curves) To calculate pump air consumption (m 3 /min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (MPa/bar/psi), use the following instructions and pump data chart. 1. Locate desired fluid flow along bottom of chart. 2. Follow vertical line up to intersection with selected air pressure curve (gray). Follow horizontally right to read air consumption. Key: A 180 psi (1.2 MPA, 12.4 bar) B 100 psi (0.7 MPA, 7 bar) C 70 psi (0.5 MPa, 7.8 bar) D 40 psi (0.3 MPa, 2.8 bar) 350 (24.5, 245) 24 (0.672) Outlet Pressure in PSI (MPa, bar) 300 (21, 210) 250 (17.5, 175) 200 (14, 140) 150 (10.5, 105) 100 (7, 70) 50 (3.5, 35) 0 D D C (1.9) (3.8) (5.7) (7.6) (9.5) (11.4) Fluid Flow in gpm (lpm) B C A B A 3.5 (13.2) 4 (15.1) 20 (0.560) 16 (0.448) 12 (0.336) 8 (0.224) 4 (0.112) Air Consumption in SCFM (m 3 /min) N
29 Technical Data N 29
30 Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation. THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale. GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties. In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise. FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées. Graco Information For the latest information about Graco products, visit TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: or Toll Free: Fax: All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. For patent information, see Original instructions. This manual contains English. MM Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC. AND SUBSIDIARIES P.O. BOX 1441 MINNEAPOLIS MN USA Copyright 2008, Graco Inc. All Graco manufacturing locations are registered to ISO Revised December 2013
Leak Detection System
Instructions - Parts List Leak Detection System 311200A For detecting leaks in your diaphragm pump system. Not for use in explosive atmospheres. Part No. 234576 120 psi (0.8 MPa, 8 bar) Maximum Air Input
- For pumping exact amounts of lubrication fluids from a reservoir to specific lubrication points -
Instructions DSL/SVK Pumps 313261D ENG - For pumping exact amounts of lubrication fluids from a reservoir to specific lubrication points - DSL Models: 256907, 256908, 256929 3000 psi ( 20.7 MPa, 206.8
Instructions. Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG. Pressure Relief Procedure.
Instructions Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG Model 24G766 Important Safety Instructions For complete warnings and safety instructions see RoadLazer RoadPak
Feed Pump and Agitator Kits
Instructions - Parts Feed Pump and Agitator Kits 2769D EN Supplies viscous materials from drums or 20 gallon hoppers to XM and XP70 plural-component sprayers. Important Safety Instructions Read all warnings
Pump for Drywall Feed Pump System
Repair Pump for Drywall Feed Pump System 3A0912A ENG - For water-based materials only - - Not for use in explosive atmospheres - - Not for use with quick-set materials - READ ALL WARNINGS AND INSTRUCTIONS
Extrusion Flo-Valve INSTRUCTIONS-PARTS LIST. 3000 psi (210 bar) Maximum Working Pressure. Model 204 355, Series K. Rev.
INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 306 586 Rev. D Supercedes B Extrusion Flo-Valve Model 204 355, Series K 3000 psi
Fluid Regulator. Instructions Parts List 306563L LOW PRESSURE
Instructions Parts List LOW PRESSURE Fluid Regulator 306563L For accurate, positive control of fluid pressure to one spray gun, dispensing valve, or atomizing head. For professional use only. 250 psi (18
55-Gallon Dispenser Package
INSTRUCTIONS-PARTS LIST Husky 515 55-Gallon ispenser Package 08666 Rev. C INSTRUCTIONS This manual contains important warnings and information. REA AN KEEP FOR REFERENCE. 100 psi (6.9 bar) Maximum Air
Instructions Parts List
Instructions Parts List AIR DRIVEN Twistork Helix Mixer 30875P 00 psi (0.7 MPa, 7 bar) Maximum Working Pressure Model 224854, Series D Carbon Steel Agitator Model 235534, Series D Stainless Steel Agitator
OP300S / OP350 2:1 RATIO TRANSFER PUMP
OP300S / OP350 2:1 RATIO TRANSFER PUMP OPERATING MANUAL WITH PARTS IDENTIFICATION Copyright 2013 International Pump Manufacturing, Inc. This manual contains IMPORTANT WARNINGS and INSTRUCTIONS. Read and
Battery Charger. Instruction Manual 309502G
Instruction Manual Battery Charger 309502G EN Part No. 117427, Single Bay Charger, Series B, North America (N.A.) Part No. 120110, Single Bay Charger, Series B, Australia Part No. 117429, Four Bay Charger,
Ultra-Lite In-Line Flow Gun
INSTRUCTIONS-PARTS LIST 308 807 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. First choice when quality counts. Rev. B Supersedes A Ultra-Lite In-Line
GH 833 Sprayers 311283C
Repair GH 833 Sprayers Korean patent: 10-0647761 311283C - Use with Architectural Coatings, Paints, Roof Coatings and Below Grade Coatings - 4000 psi (27.6 MPa, 275.8 bar) Maximum Working Pressure Important
Graymills. Air Operated Double Diaphragm Pumps. Operations and Maintenance Instructions
795 08690 GM 12 00 Graymills Air Operated Double Diaphragm Pumps Operations and Maintenance Instructions /S Read all these SAFETY INSTRUCTIONS BEFORE installing or using this equipment. Keep this manual
AirPro Gravity Feed Airspray Gun
Instructions-Parts AirPro Gravity Feed Airspray Gun 312579K EN Conventional, HVLP, and compliant guns for specialty industrial applications. For professional use only. 100 psi (0.7 MPa, 7 bar) Maximum
In-Line Filters and Coalescers with Automatic Drains
Instructions/Parts In-Line Filters and Coalescers with Automatic Drains 310611G EN Air Filter with Automatic Drain Part No. 22601, Series B Maintenance To maintain maximum filtering efficiency and to avoid
15:1 Fire-Ball 300 Pumps
Instructions Parts List 15:1 Fire-Ball 300 Pumps 306531Z1 For pumping petroleum based undercoating material. 2700 psi (18.6 MPa, 186 bar) Maximum Working Pressure 180 psi (1.2 Ma, 12 bar) Maximum Air Input
ADP Autoline 3A0986A ENG
ADP Autoline 3A0986A ENG Definition of Terms Definition of Terms DMS: Dealer Management System Generic term referring to the business system a car dealership or similar organization uses to manage their
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
Test Fixture, High Voltage Probe, and kv Meter
Instructions/Parts List Test Fixture, High Voltage Probe, and kv Meter 309455B EN For Graco Pro Xp and PRO Xs Electrostatic Spray Guns, to test the electrostatic voltage of the spray gun, as well as the
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will
IMPORTANT SAFETY NOTICE
IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds
3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
PALLET JACK - 2.5 TON
PALLET JACK - 2.5 TON 39939 SET UP AND OPERATING INSTRUCTIONS Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious injury.
Installation, Maintenance, & Repair Series 4000B/LF4000B
Installation, Maintenance, & Repair Series 4000B/LF4000B Reduced Pressure Zone Assemblies Sizes: 1 2" 2" (15 50mm) RP/IS-A-4000B 4000B/LF4000B Size: 3 /4"! WARNING Testing Read this Manual BEFORE using
PAINT SPRAY GUN WASHER
PAINT SPRAY GUN WASHER 94996 ASSEMBLY AND OPERATING INSTRUCTIONS Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious
Trouble Shooting. Pump
Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft
Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW
Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...
PBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT
POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric
ROUGHNECK II Pumpless Drain
SERVICE BULLETIN SB4027 Rev. I 1/11 For Used Oil Only ROUGHNECK II Pumpless Drain Model #4110-022 FOR USED OIL ONLY (Black) For Antifreeze Only Model #4110-023 FOR USED ANTIFREEZE ONLY (Green) Patent #
Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19
Table of Contents Overview 1 Pump Disassembly 2 Control Disassembly / Reassembly 7 Pump Reassembly 13 Adjustment Procedures DR Control 19 Adjustment Procedures DRG Control 20 Adjustment Procedures DFR
Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet Address: http://www.powerteam.
ORIGINAL INSTRUCTIONS Form No.102842 5 SPX Hydraulic Technologies 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800)
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
MODEL G300 BRAKE BLEEDER
MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY
Rexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html TECHNICAL SERVICE DEPARTMENT Removal, Cleaning, & Reinstallation of the Burner Assembly For models 74 & GT199 Required tools -
2:1 RATIO TRANSFER PUMP
OP232-INST 2:1 RATIO TRANSFER PUMP OPERATING MANUAL WITH PARTS IDENTIFICATION IPM INC. Manufactured by International Pump Manufacturing, Inc. Covers models: OP232C, OP242CD and OP242A. Manual Number: MOP232062008
National- Spencer Inc.
9-27-2010 National- Spencer Inc. 19.2V HEAVY DUTY GREASE GUN PRODUCT SPECIFICATION Charger Input Power 110 VAC Battery Output Power 19.2V Battery Capacity 1500 MAH Battery Pack Charge Time 1 Hour Maximum
Instructions Parts List
Instructions Parts List ALUMINUM AND STAINLESS STEEL Husky 590 Air-Operated Diaphragm Pumps 0844ZAG.5 inch AODD pump for fluid transfer applications. For professional use only. See Models on page for a
PET-10 INSTRUCTION MANUAL PRESSURE TANK
INSTRUCTION MANUAL PRESSURE TANK PET-10 This manual contains IMPORTANT WARNINGS and INSTRUCTIONS. Equipment in this manual is exclusively for painting purposes. Do not use for other purposes. The operator
SE-100-1, SE-200-1, SE-500-1, and SE-1000-1 AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81) 83 54 10 18 ventas@industrialmagza.
AIR CHAMP PRODUCTS User Manual SE BRAKE MODELS: SE-00-, SE-200-, SE-500-, and SE-000- (i) FORM NO. L-20084-E-040 In accordance with Nexen s established policy of constant product improvement, the specifications
HYDRAULIC TABLE CART
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
240-3118 AIR CUT OFF KIT INSTALLATION INSTRUCTIONS
OPERATION MANUAL GLOBAL ELECTRONIC MIX SOLUTIONS PLURAL COMPONT MIXING SYSTEM 240-3118 AIR CUT OFF KIT INSTALLATION INSTRUCTIONS 77-3087-R1.0 (8/2015) 1 / 5 In this part sheet, the words WARNING, CAUTION
81000 Series Aluminum Gate Valve Installation and Repair Manual
High Vacuum Valves Leader in Quality and Value 81000 Series Aluminum Gate Valve Installation and Repair Manual Dear Customer, Thank you for choosing HVA as your vacuum valve supplier. Your valve will give
INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303
WATER MIST HAND PORTABLE FIRE EXTINGUISHERS Model B270 ¾ Gallon Model B272 2 ½ Gallon INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 6303 All fire extinguishers should be installed, inspected
ROTOR LOADER OWNER S MANUAL
ROTOR LOADER OWNER S MANUAL ROTOR LOADER OWNER S MANUAL WARNING IMPORTANT SAFETY INSTRUCTIONS AND GUIDELINES. Misuse of paintball equipment may cause serious injury or death. QUICK SET-UP GUIDE BATTERY
1/3 HP Submersible Sump Pump with Vertical Float Switch
1/3 HP Submersible Sump with Vertical Float Switch Item 68476 Specifications Float Switch Operation Height 7.1 IN. ON / 2.8 IN. OFF Electrical Requirements 120V~ / 60Hz / 7.6A Power Length Maximum Capacity
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
Installation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
Cable Drum Machine. Operation Manual BC260 SERIES. Cleans 1 1/4" to 3" lines up to 50'
Cable Drum Machine Operation Manual BC260 SERIES Cleans 1 1/4" to 3" lines up to 50' Used For: Sink, Shower & Floor Drains 42FM " WARNING - Read All Instructions, When Using Electric Tools, Basic Safety
TECHNICAL DATA. Dry 122a. November 12, 2013
Dry 122a 1. PRODUCT DESCRIPTION The Viking is a quick-opening device. When installed with the required external Anti-flood Device, the assembly is designed to increase the operating speed of Viking Model
BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: 3402270 & 3402275 OPERATING & MAINTENANCE INSTRUCTIONS GC04/12
BACKPACK SPRAYERS MODEL NOS: KSP16 & KSP20 Part Nos: 3402270 & 3402275 OPERATING & MAINTENANCE INSTRUCTIONS GC04/12 INTRODUCTION Thank you for purchasing this CLARKE Sprayer, designed for use only with
Stainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL Congratulations on choosing the Fascination 700 HVLP Tanning Pro System! Your system includes the following items: 1 Fascination 700 HVLP Tanning Pro
OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION
OPERATING INSTRUCTIONS Shortening Filter Model No. 99-A, 102-A, & 107-A Series TABLE OF CONTENTS PAGE Installation... 2 Operating... 3 Cleaning... 5 Parts List... 6 & 7 Troubleshooting... 8 LIMITED WARRANTY
GlasCraft Catalyst Pump
Repair - Parts GlasCraft Catalyst Pump 3A1218H EN For use with Graco polyester resin and gel coat systems. For professional use only. See page 2 for models. Important Safety Instructions Read all warnings
Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50
Back Pack Sprayer Operator's Manual MODELS MS - 40 MS - 50 WARNING DANGER Read rules for safe operation and all instructions carefully. ECHO provides this Operator's Manual which must be read and understood
Trillium 40 Axis Spring Tensioner Wire Replacement Instructions
Trillium 40 Axis Spring Tensioner Wire Replacement Instructions 1 Overview The objective is to replace the broken axis spring tensioner wire. This requires the following tasks: 1. Remove the seismometer
USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2
Remote Faucet Pump System USE &CARE GUIDE See Important Safeguards on page 2 An exclamation point within an equilateral triangle is intended to alert user to the presence of important operating and maintenance
Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer
Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve
1 / 4 IN. FFL x 4 FT. 9 IN. 1 / 2 IN. ACME x 4 FT. 9 IN. Gauge Accuracy +/-2% Set includes Quick Disconnect Valves
Specifications Blue (Low) Gauge 0-120 PSI Blue Hose 1 / 4 IN. FFL x 4 FT. 9 IN. Red (High) Gauge 0-500 PSI Red Hose 1 / 4 IN. FFL x 4 FT. 9 IN. Yellow Hose 1 / 2 IN. ACME x 4 FT. 9 IN. Gauge Accuracy +/-2%
DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information
Safety Safety Is Your Responsibility DANGER To avoid personal injury or death, carefully read and understand all instructions pertaining to the Anthony Liftgates product. Do not attempt to install, operate,
Dryaire Desiccant System
Instructions/Parts Dryaire Desiccant System 310595F Model 6760 Maximum Operating Pressure: 160 PSI (1.1 MPa, 11 bar) System Description Sharpe s DRYAIRE Desiccant Air Drying System is the painter s insurance
Chapter 7 Hydraulic System Troubleshooting
Chapter 7 Hydraulic System Troubleshooting General The following troubleshooting information is provided as a general guide to identify, locate and correct problems that may be experienced with the hydraulic
Fuel Injection Pump, Rotary (005-014)
Fuel Injection Pump, Rotary View Related Topic Page 1 of 30 Fuel Injection Pump, Rotary (005-014) Table of Contents Summary General Information Preparatory Steps Remove Front Gear Train Rear Gear Train
Parts. Ultra 395/495/595t Ultra Max II 490/495/595t 309675V 120 VAC. 3300 psi (228 bar, 22.8 MPa) Maximum Working Pressure.
Parts Ultra 395/495/595t Ultra Max II 490/495/595t 309675V EN 3300 psi (228 bar, 22.8 MPa) Maximum Working Pressure 0 VAC Type Stand Series Lo-boy Series Hi-boy Series Ultra 395t 2339 B 233961 B 233962
PC1130 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1130 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
Owner s Manual. Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE
Owner s Manual Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE WARNING!! Installation & Operating Instructions Self-Priming Centrifugal Pump DO NOT
Hydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
Unit: mm(in) Item Standard value Service limit Axle shaft run out - 0.2(0.008)
Rear Wheel/Brake/Suspension 13. Rear Wheel/Brake/Suspension Service Information 13-1 Troubleshooting 13-2 Rear Wheel 13-3 Rear Cushion 13-4 Rear Swing Arm 13-7 Service Information General Safety If the
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
STORED PRESSURE STAINLESS STEEL
STORED PRESSURE STAINLESS STEEL WATER FIRE EXTINGUISHERS Model 240-2-1/2 Gallon OWNER'S SERVICE MANUAL NO. 05601 INSPECTION, MAINTENANCE AND RECHARGE All fire extinguishers should be installed, inspected
tire inflator with pressure gauge
tire inflator with pressure gauge Model 95583 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks
Installation Instructions for Alarm Module Kit A043F059
Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS
INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS SETTING UP THE PRESS FOR OPERATION For shipping convenience, the gauge, pump handle, hoist crank, screw nose and base angles
IMPORTANT DOCUMENTATION DO NOT DISCARD!
PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance
Instructions Parts List
Instructions Parts List ALUMINUM, STAINLESS, AND DUCTILE IRON Husky50 Air Operated Diaphragm Pumps 308368ZAG inch AODD pump for fluid transfer applications. For professional use only. See Models on page
Char-Lynn Hydraulic Motor. Repair Information. 10 000 Series. October, 1997
Char-Lynn Hydraulic Motor October, 1997 Repair Information Geroler Motor Two Speed 001 27 Retainer inside bore of valve plate bearingless motors only 4 15 16 3 6 35 Parts Drawing 25 2 2 1 19 17 36 40 47
Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)
17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning
FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions
FJ2 2 Ton Trolley Floor Jack Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.
Wilo SP Series Submersible Sump Pumps ECS. ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions
Wilo SP Series Submersible Sump Pumps ECS ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions PREINSTALLATION CHECK Inspect this pump before it is used. Occasionally, pumps can
Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1
Hydraulic Air Riveter Recommend for mass production line industrial area Operation Manual RC197 RC198 Page 1 CONTENTS 1 Important Safety Rules 2 Tool Specification 2.1 Nomenclature 2.2 Technical Data 3
M A N U A L 13-10-05
Documentation The following information sheets illustrate the description below: 12-WW01-4G-E Sectional view of the lance with main dimensions 12-W101-6G-E Sectional view of the head of the lance with
Hydraulic Trouble Shooting
Hydraulic Trouble Shooting Hydraulic systems can be very simple, such as a hand pump pumping up a small hydraulic jack, or very complex, with several pumps, complex valving, accumulators, and many cylinders
BINKS MODEL 460 LIGHTWEIGHT AUTOMATIC SPRAY GUN
SERVICE MANUAL EN BINKS MODEL 460 LIGHTWEIGHT AUTOMATIC SPRAY GUN AIR FLOW ADJUSTMENT Clockwise to reduce pressure; Counterclockwise to increase pressure. 1/2" DIA. MOUNTING HOLE FLUID NEEDLE ADJUSTMENT
Instructions Parts List
Instructions Parts List ACETAL AND POLYPROPYLENE Husky 307 Air Operated Diaphragm Pumps For fluid transfer applications. For professional use only. Only pumps with acetal fluid sections are approved for
3 WATT LED SPOTLIGHT Model No. SLM - 3801
3 WATT LED SPOTLIGHT Model No. SLM - 3801 OWNER'S MANUAL Customer Service Tel: 1-800-268-3319 Superex Canada Ltd, Toronto,M2H 3B8 Made in China Table of Contents A). Important Safety Instructions B). Charging
Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
STEERING SYSTEM - POWER
STEERING SYSTEM - POWER 1990 Nissan 240SX 1990 STEERING Nissan - Power Rack & Pinion Axxess, Maxima, Pulsar NX, Sentra, Stanza, 240SX, 300ZX DESCRIPTION The power steering system consists of a rack and
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 [email protected] www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS
USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling
JC Carter LLC LNG Couplings USER MANUAL 10 GPM Small Single Line Cryogenic Coupling Models 50E722 Nozzle and 50E721 Receptacle User s Manual and Installation Guide! Warning: Read the User s Manual and