1 Composite OEM Products Porcelain PRODUCTS CATALOG Hardware Glass
2 ABOUT US Our mission at GAMMA can be summed up in one simple, yet effective phrase: Provide Consistently High Quality Products Supported by Best in Class Customer Service. SERVICE IS OUR PASSION Customer satisfaction is our number one priority, setting GAMMA apart from all other manufacturers. Our goal is to continually exceed expectations in product quality, application solutions, timely response, product knowledge, and customer service Every Customer, Every Contact, Every Time! RESPECT AND COMMITMENT Human talent and potential is our greatest asset; at GAMMA, we facilitate both the personal and professional development of all our employees. GAMMA employees work in a friendly and safe environment, where respect and dignity are expected, and the values of honesty, ethics and accountability stand at the forefront of all our actions. INNOVATION AND CONTINUOUS IMPROVEMENT Freedom to innovate coupled with a culture that promotes continuous improvement inspires GAMMA employees to achieve the highest standards of excellence. Using tried-and-true practices and techniques, we analyze, measure, and test our products and processes to ensure consistent quality. We relentlessly pursue ways to innovate, reduce costs, and increase efficiency in order to add value to our customers. INVEST IN THE FUTURE GAMMA s business operates in a fiscally responsible manner, because only a financially healthy company can lead an industry with the highest level of products and services. Financially sound companies also have the flexibility to make strategic, long-term decisions, rather than resorting to last-ditch, short-term fixes. As a company in business for the long term, GAMMA makes current and future investments a key business strategy for the development of our company.
3 SOCIALLY CONSCIOUS Committed to being a socially conscious organization, we make it our goal to improve the environment in which we operate. GAMMA actively participates in economic development projects, environmental protection practices, and the sustainability of the natural resources used in producing our products. Throughout our 50-year history of manufacturing, GAMMA has maintained its primary focus on the utility industry we take pride both in the products we offer and our position as an industry leader in manufacturing. Productivity and global efficiency, along with social and environmental responsibility, form the foundation of our organization and allow us achieve our goal of Total Customer Satisfaction. Experience the GAMMA Difference! Mauricio Yepes General Manager, Gamma Insulator Corporation ABOUT GAMMA INSULATORS CORPORATION GAMMA Insulator Company is the utility products manufacturing subsidiary of the Corona Group, a multinational conglomerate with over 130 years manufacturing experience. Corona has nine manufacturing facilities throughout the United States and Colombia, and automated warehouses within easy reach of 32 markets worldwide. Corona s state-of-the-art manufacturing facilities utilize the latest technologies and are all certified to the latest ISO 9001, and OHSAS standards. We employ world-class manufacturing tools and management systems such as TMP, Lean Manufacturing, DFSS, and Six Sigma to produce the high quality products you have come to expect from GAMMA. The GAMMA manufacturing facility, located in Colombia, South America, near the city of Medellin, is optimally located to serve the both North American and South American utility markets. With access to the Atlantic and Pacific Oceans, factory-direct shipments to the US and Canada are measured in days rather than weeks. In addition, GAMMA s fully stocked North American warehouse, located in Savannah, GA, provides a solution for all immediate fulfilment needs.
4 Suspensions Polymer Dead Ends Spools Guy Strains Fiberglass Guy Strain Pins Posts Polymer Line Post Clamp Tops Station Posts Hardware
5
6 Suspension type insulators mechanically hold the conductor thus isolating it from contact with land and other conductors. GAMMA suspensions support mechanical and electrical charges ranging from 15,000 to 30,000 lbs. and are available in all tension levels, for both distribution and transmission systems. Porcelain suspensions are specifically designed to comply with ANSI CLASS (C ) standards, ensuring the performance of both the electrical and mechanical functions, as well as to satisfy all dimensional specifications and applicable requirements. The porcelain suspensions portfolio includes FOG type insulators for high-contaminated environments. These are offered in brown or gray glaze according to customer preferences and standards for each country. Post and cable mount hardware allow insulators to be fixed in suspension and retention designs for a perfect connection. These are manufactured in galvanized steel with different configurations, including double galvanized layer or zinc sleeve characteristics that satisfy all mounting requirements.
7 1/2 5/8 5 1/2 11/16 11/16 7/8 6 1/2
8 1/2 5/8 11/16 11/16 6 1/4 7/8 4 3/4
9 5 3/4 10 3/4
10 1/2 5/8 11/16 5 3/4 11/16 11/ /4
11 5 3/4 10 3/4
12 1/2 5/8 11/6 5 3/4 11/6 10 3/4
13
14 Suspension type polymer insulators mechanically hold the conductor cable and electrically isolate it both from contact from the land and from other conductors. GAMMA polymer suspensions support mechanical loads ranging from 15736lb to lbs., with resisting tensions between 15kV and 69kV for distribution, and between 115kV and 500kV for transmission. Polymer insulators are designed and manufactured according to IEC and ANSI C29.13 standards, to satisfy all applicable requirements, as well as to ensure the quality and performance of the product throughout its length of service. Polymer dead ends are manufactured with the highest quality raw materials to ensure a perfect assembly between the fiberglass nucleus and HTV silicone. Due to this and to the hydrophobic characteristics of the silicone, humidity cannot enter the nucleus, thus preventing deterioration of the insulator and extending its service life. These products are lightweight, resistant to vandalism, and immune to damage due to ultraviolet rays or solar radiation. These insulators have an aerodynamic design to facilitate self-cleaning by wind and rain. All polymer suspension end fittings are designed to satisfy their mechanical and electrical functions. We offer different combinations of iron fittings for distribution and transmission lines assemblies: clevis, thimble, ball and socket and Y-clevis type. Depending on the installation site and customer requirements, we also offer iron fittings with a double galvanized layer for use in contaminated environments. Polymer Dead Ends Clevis - tongue Polymer Dead Ends ball and socket PS015 PS025 PS035 PS045 PS069 PS015B PS025B PS035B PS035B80 PS69S1201 Polymer Dead Ends Y-Clevis - tongue Polymer Dead Ends Y-Clevis - ball PS69Y1201 PS69B1201 Polymer Dead Ends Tongue - tongue PS003 Content
15 Polymer dead ends Clevis - Tongue H C A 3 1/2" 1 1/16" 5/8 CATALOG NUMBER ANSI CLASS (C ) PS015 PS025 PS035 DS-15 DS-28 DS-35 CRITICAL DISTANCES, inches Dry arcing distance Leakage distance 7 1/2 16 2/ / / /8 36 MECHANICAL VALUES Specified mechanical load (SML) pounds Routine test load (RTL) pounds Torsional load, lbf.ft ELECTRICAL VALUES,kV Typical application voltage Low-frequency dry flashover Low-frequency wet flashover Critical impulse flashover positive RADIO INFLUENCE DATA Test voltage, kv Maximum RIV 1000 khz, μv DIMENSIONS ACCORDING TO DRAWING Total height H, inches Length C, inches Number of sheds, A < 10 < 10 < /4 18 5/8 22 3/ / / Note 1: Polymer housing: high voltage silicone Note 2: End fitting: nodular galvanized iron
16 Polymer dead ends Clevis - Tongue H C A Ø3 7/10 1 1/16" 5/8 CATALOG NUMBER ANSI CLASS (C ) CRITICAL DISTANCES, inches Dry arcing distance Leakage distance PS045 DS / /16 PS069 DS /8 MECHANICAL VALUES Specified mechanical load (SML) pounds Routine test load (RTL) pounds Torsional load, lbf.ft ELECTRICAL VALUES,kV Typical application voltage Low-frequency dry flashover Low-frequency wet flashover Critical impulse flashover positive RADIO INFLUENCE DATA Test voltage, kv Maximum RIV 1000 khz, μv DIMENSIONS ACCORDING TO DRAWING Total height H, inches Length C, inches Number of sheds, A < 10 < / / Note 1: Polymer housing: high voltage silicone Note 2: End fitting: nodular galvanized iron
17 Polymer dead ends Ball and socket H C A Ø3 1/2 CATALOG NUMBER ANSI CLASS (C ) PS015B PS025B PS035B DS-15 DS-28 DS-35 CRITICAL DISTANCES, inches Dry arcing distance Leakage distance 7 1/2 16 2/ / / /8 36 MECHANICAL VALUES Specified mechanical load (SML) pounds Routine test load (RTL) pounds Torsional load, lbf.ft ELECTRICAL VALUES,kV Typical application voltage Low-frequency dry flashover Low-frequency wet flashover Critical impulse flashover positive RADIO INFLUENCE DATA Test voltage, kv Maximum RIV 1000 khz, μv DIMENSIONS ACCORDING TO DRAWING Total height H, inches Length C, inches Number of sheds, A < 10 < 10 < /2 17 3/ / /5 20 3/ Note 1: Polymer housing: high voltage silicone Note 2: End fitting: nodular galvanized iron
18 Polymer dead ends Ball and socket 21 1/10" 20 6/10" 3 6/10" CATALOG NUMBER ANSI CLASS (C ) CRITICAL DISTANCES, inches Dry arcing distance Leakage distance MECHANICAL VALUES Specified mechanical load (SML) pounds Routine test load (RTL) pounds Torsional load, lbf.ft ELECTRICAL VALUES,kV Typical application voltage Low-frequency dry flashover Low-frequency wet flashover Critical impulse flashover positive RADIO INFLUENCE DATA Test voltage, kv Maximum RIV 1000 khz, μv PS035B80 DS / / < 10 Note 1: Polymer housing: high voltage silicone Note 2: End fitting: nodular galvanized iron
19 Polymer dead ends Ball and socket 32 3/5 31 3/10 A Ø3 1/2 CATALOG NUMBER ANSI CLASS (C ) CRITICAL DISTANCES, inches Dry arcing distance Leakage distance MECHANICAL VALUES Specified mechanical load (SML) pounds Routine test load (RTL) pounds Torsional load, lbf.ft ELECTRICAL VALUES,kV Typical application voltage Low-frequency dry flashover Low-frequency wet flashover Critical impulse flashover positive RADIO INFLUENCE DATA Test voltage, kv Maximum RIV 1000 khz, μv PS69S1201 DS / < 10 DIMENSIONS ACCORDING TO DRAWING Number of sheds, A 13 Note 1: Polymer housing: high voltage silicone Note 2: End fitting: nodular galvanized iron
20 Polymer dead ends Y Clevis - tongue 34 2/5 Ø7/ /5 A 45 Ø3 1/2 Ø20.0 CATALOG NUMBER ANSI CLASS (C ) CRITICAL DISTANCES, inches Dry arcing distance Leakage distance MECHANICAL VALUES Specified mechanical load (SML) pounds Routine test load (RTL) pounds Torsional load, lbf.ft ELECTRICAL VALUES,kV Typical application voltage Low-frequency dry flashover Low-frequency wet flashover Critical impulse flashover positive RADIO INFLUENCE DATA Test voltage, kv Maximum RIV 1000 khz, μv PS69Y1201 DS / < 10 DIMENSIONS ACCORDING TO DRAWING Number of sheds, A 13 Note 1: Polymer housing: high voltage silicone Note 2: End fitting: nodular galvanized iron
21 Polymer dead ends Y Clevis - ball Ø A 45 Ø95.0 CATALOG NUMBER ANSI CLASS (C ) CRITICAL DISTANCES, inches Dry arcing distance Leakage distance MECHANICAL VALUES Specified mechanical load (SML) pounds Routine test load (RTL) pounds Torsional load, lbf.ft ELECTRICAL VALUES,kV Typical application voltage Low-frequency dry flashover Low-frequency wet flashover Critical impulse flashover positive RADIO INFLUENCE DATA Test voltage, kv Maximum RIV 1000 khz, μv PS69B1201 DS / < 10 DIMENSIONS ACCORDING TO DRAWING Number of sheds, A 13 Note 1: Polymer housing: high voltage silicone Note 2: End fitting: nodular galvanized iron
22 Polymer dead ends Tongue - tongue 13 1/2" 11 13/16" 3 1/2" CATALOG NUMBER CRITICAL DISTANCES, inches Dry arcing distnace Leakage distnace PS MECHANICAL VALUES Specified mechanical load (SML), pounds Routine test load (RTL), pounds) 7868 Torsional load, lbf.ft 35 ELECTRICAL VALUES,kV Typical application voltage 3 (Direct Current) Low-frequency dry flashover 74 Low-frequency wet flashover 54 RADIO INFLUENCE DATA Total height H, inches 13 1/2 Length C, inches 1113/16 Note 1: Polymer housing: high voltage silicone Note 2: End fitting: nodular galvanized iron
23 Spool
24 Spool These support type insulators are designed to provide the energized conductor cable a support point to keep it separated from the low-tension lines structures. These are installed in iron fittings known as hangers, in individual units or in groups. They have a transversal resistance ranging from 2000 to 6000 lbs. depending on the spool size. Spool Content
25 Spool 2 1/4 1 3/4 7/8 3 1/8 1 3/4 15/ /4 15/16 1/2 3/4 3/4 R 3/8 2 1/8 R 7/16 3 R 11/ / / /64 CATALOG NUMBER ANSI CLASS (C rev.2002) MECHANICAL VALUES, pounds Transverse str ength ELECTRICAL VALUES, kv Low-frequency dry flasho ver Low-frequency wet flasho ver, vertical Low-frequency wet flasho ver, horizontal Note: ANSI 70 gr ay is standar d. Brown or white a vailable by r equest
26 Spool 3 1 3/4 15/16 4 1/ /8 15/16 3/4 2 7/8 15/ /16 R 7/16 3 3/4 R 5/8 4 1/8 R 7/ /16 11/ /16 CATALOG NUMBER ANSI CLASS (C rev.2002) MECHANICAL VALUES, pounds Transverse str ength ELECTRICAL VALUES, kv Low-frequency dry flasho ver Low-frequency wet flasho ver, vertical Low-frequency wet flasho ver, horizontal Note: ANSI 70 gr ay is standar d. Brown or white a vailable by r equest
27 Guy strain
28 Guy strain Guy strain type porcelains are used in low and medium voltage lines. They are designed to work in mechanical tension (strain), to withstand the pull of a suspended electrical wire or cable. Guy strains are used in overhead electrical wiring to support radio antennas and overhead power lines. A strain insulator may be inserted between two lengths of wire, to isolate them electrically from each other while maintaining a mechanical connection, or where a wire attaches to a pole or tower, to transmit the pull of the wire to the support while insulating it. GAMMA guy strain type insulators are designed, manufactured and tested according to ANSI standard (C ) using wet shaping processes. These insulators work under compression efforts instead of tension. Insulator s surface is covered with a waterproof glaze coat, which allows the porcelain to stay free from dust and dirt caused by environmental contamination. Gray, white or brown glazing is available according to customer requirements. Guy strain Content
29 Guy strain 2 7/8" 2 1/2" 3 1/2" 2 1/2" 1 3/4" 1 3/4" 4 1/4" 2 1/4" 3" 2 1/8" 5/8" 7/8" CATALOG NUMBER ANSI CLASS (C rev.2002) CRITICAL DISTANCES, inches Leakage distance /8 1 7/8 MECHANICAL VALUES, pounds Tensile strength ELECTRICAL VALUES, kv Low-fr equency dry flasho ver Low-frequency wet flasho ver Note: ANSI 70 gr ay is standar d. Brown or white available by request
30 Guy strain 3 1/2" 5 1/2" 4 1/16" 2 3/8" 3 3/8" 6 3/4" 2 5/8" 4 1/2" 2 3/8" 3 1/8" 1" 1" CATALOG NUMBER ANSI CLASS (C rev.2002) CRITICAL DISTANCES, inches Leakage distance /4 3 MECHANICAL VALUES, pounds Tensile strength ELECTRICAL VALUES, kv Low-fr equency dry flasho ver Low-frequency wet flasho ver Note: ANSI 70 gr ay is standar d. Brown or white available by request
31 Pin
32 Pin Pin type insulators are designed to provide line support. The function of these insulators is to support the conducting cable directly on the head or neck of the insulator (top and side grooves). Pin type insulators are designed and manufactured according to ANSI standard (C ) in order to ensure their electrical and mechanical performance, as well as to satisfy all dimensional specifications and requirements. We offer low and medium voltage pins, and are used in distribution lines ranging from 7.2kV to 34 Kv. These insulators are also offered with a semi-conductive glaze, generally used to homogenize the field generated by the electrical path through the conductor that may cause radio interference. Pin type insulators are mounted on metallic cross arms, wood cross arms or directly on the post. GAMMA offers the appropriate iron fittings for each assembly, including fittings with nylon thread mounting studs replace traditional studs made with lead. Among the beneficial properties of the nylon thread mounting studs is that these do not impact the environment or adversely affect the health of individuals manipulating them. Low - medium voltage Pin insulators 6188R R RA R R-70 High voltage Pin insulators R R R R-70 Content
33 Low - medium voltage Pin 3 1/4" 1 1/2" 3 1/2" 2 1/4" R 5/8" R 5/8" 3 3/4" 1 1/2" 3 3/8" 2 1/4" R 9/16" R9/16" 3 3/4 1 1/2 3 3/8 2 1/4 Ø 1 7/10 R 9/16 3 3/4" 6188R /4" 6184R /4 6184RA-70 4" 2 7/8" R 1" 4" 2 7/8" RF 1" R 9/16" RF 9/16" 4 3/8"1 3/4" 4 7/8"2" CATALOG NUMBER ANSI CLASS (C rev. 2002) CRITICAL DISTANCES, inches Dry ar cing distance Leakage distance Minimum pin heigh t MECHANICAL VALUES, pounds Cantilever str ength ELECTRICAL VALUES, kv Typical applica tion voltage Low-frequency dry flasho ver Low-frequency wet flasho ver Critical impulse flasho ver, positive Critical impulse flasho ver, negative Low-frequency puncture voltage 5 19/32" 6183R-70 RADIO INFLUENCIA VOLTAGE DATA Low-frequency test voltage, RMS to gr ound, kv Maximum R IV at 1000 khz, μv 6188R R RA R R /8 4 1/2 4 1/ / " 7061R Note 1: ANSI 70 gr ay is standar d. Brown or white a vailable by r equest Note 2: Conductive Glaz e - applied to head, side wir e grooves and pin hole for one-piece units Note 3: Neck Siz es - C & F according to industry standards Note 4: Pin Hole Siz es - Standar d 1 to 15 kv and r ef R -70, 1 3/8 for the r est of 23 kv & 35 kv units
34 High voltage pin 4 5/8 4 3/4" 3 1/2" R 1" R 5/8" 3 1/2 R 3/4 R 9/16 5 1/2" 2 1/4" 5 3/ /8" 7 1/ R R /8 5 1/4 4 4 R 3/4 R 3/4 R 9/16 R 9/16 6 1/ / R /2 8190R-70 CATALOG NUMBER ANSI CLASS (C rev. 2002/C rev CRITICAL DISTANCE, inches Dry ar cing distance Leakage distance Minimum pin heigh t MECHANICAL VALUES, pounds Cantilever str ength ELECTRICAL VALUES, kv Typical applica tion voltage Low-frequency dry flasho ver Low-frequency wet flasho ver Critical impulse flasho ver, positive Critical impulse flasho ver, negative Low-frequency puncture voltage R R R R /4 9 1/ / RADIO INFLUENCIA VOLTAGE DATA Low-frequency test voltage, RMS to gr ound, kv Maximum R IV at 1000 khz, μv Note 1: ANSI 70 gr ay is standar d. Brown available by r equest Note 2: Conductive Glaz e - applied to head, side wir e grooves and pin hole for one-piece units Note 3: Neck Siz es - C & F according to industry standards Note 4: Pin Hole Siz es - Standar d 1 to 15 kv and r ef R -70, 1 3/8 for the r est of 23 kv & 35 kv units
35 Line post
36 Line posts are support type insulators and are installed on wooden, concrete or metal cross arms. These are especially designed for distribution lines with typical application voltages ranging from 25kV to 66kV as per standard ANSI (C ). Their strong and robust structural form provides unequalled mechanical and electrical characteristics. Nearly impervious to puncture, these insulators generally are used in areas with lighting hot zones. Designs have a cantilever resistance ranging from 6.6kN to 12.5kN. Tie top line post 9325X X X X X-70 Pin post Distribution post Insulator C neck Distribution post Insulator C neck 4315X X X X PX PX PX PX-70
37 Tie top line post 5 7/8" 2 7/8" R 1" R 1" 9 3/16" 6 1/8" 2 7/8" R 1" R 1" 9325X-70 3/4"-10 UF 6 5/16" 2 7/8" R 1" R 1" 12 7/16" 15" 3/4"/10 UF 9335X X-70 3/4"-10 UF CATALOG NUMBER ANSI CLASS (C rev. 2002) 9325X X X CRITICAL DISTANCES, inches Dry arcing distance Leakage distance MECHANICAL VALUES, pounds Cantilever strength ELECTRICAL VALUES, kv Typical application voltage Low-frequency dry flashover Low-frequency wet flashover Critical impulse flashover, positive RADIO INFLUENCE DATA Low-frequency test voltage, RMS to ground, kv Maximum RIV at 1000 khz, μv Note 1: ANSI 70 gray is standard, Brown or white available by request Note 2: can be requested with M20 thread size Note 3: Available with short or long stud, sold separately
38 Tie top line post 7" 6" 1 1/2" 7 1/2" 6" 1 1/2" 20 1/4" 21 1/4" 8416X-70 3/4-10 UF 8417X-70 3/4-10 UF CATALOG NUMBER 8416X X-70 ANSI CLASS (C rev. 2002) CRITICAL DISTANCES, inches Dry arcing distance Leakage distance MECHANICAL VALUES, pounds Cantilever strength ELECTRICAL VALUES, kv Typical application voltage Low-frequency dry flashover Low-frequency wet flashover Critical impulse flashover, positive RADIO INFLUENCE DATA Low-frequency test voltage, RMS to ground, kv Maximum RIV at 1000 khz, μv Note 1: ANSI 70 gray is standard, Brown or white available by request Note 2: can be requested with M20 thread size Note 3: Available with short or long stud, sold separately
39 Pin post 6 2 7/8 R 1 R 3/ / CATALOG NUMBER CRITICAL DISTANCES, inches Dry arcing distance 9 Leakage distance 15.5 MECHANICAL VALUES, pounds Cantilever strength 3000 ELECTRICAL VALUES, kv Typical application voltage 25 Low-frequency dry flashover 100 Low-frequency wet flashover 70 Critical impulse flashover, positive 155 Critical impulse flashover, negative 190 Low voltage puncture voltage 160 RADIO INFLUENCE VOLTAGE DATA Low-frequency test voltage, RMS to ground, kv 20 Maximum RIV at 1000 khz, μv 100 Note: ANSI 70 gray is standard. Brown or white available by request
40 Distribution post C Neck 4 4/5 2 1/4 R 1 R 1 F Neck 4 4/5 2 7/8 R 1 R 1 C Neck 5 2 1/4 R 1 R 1 F Neck 5 2 7/8 R 1 R " 3/4-10 UF 3/4-10 UF 4315X PX X-70 3/4-10 UF 4320PX-70 3/4-10 UF C Neck 5 5/32 2 1/4 R 1 F Neck 5 5/32 2 7/8 R 1 C Neck 5 2/10 2 2/10 R1" R1" F Neck 4 5/10" 2 9/10" R1" R1" R 1 R / /16 11" 11" 4327X-70 3/4-10 UF 4327PX-70 3/4-10 UF 3/4-10 UF 4335PX X-70 3/4-10 UF CATALOG NUMBER 4315X PX X PX-70 CRITICAL DISTANCES, inches Dry arcing distance 5 5 3/4 7 5/8 Leakage distance 7 1/ X X PX PX MECHANICAL VALUES, pounds Cantilever strength ELECTRICAL VALUES, kv Typical application voltage Low-frequency dry flashover Low-frequency wet flashover Critical impulse flashover, positive RADIO INFLUENCE VOLTAGE DATA Low-frequency test voltage, RMS to ground, kv Maximum RIV at 1000 khz, μv Note 1: ANSI 70 gray is standard, Brown or white available by request Note 2: Available with short or long stud, sold separately
41 Polymer Line Post
42 POLYMER LINE POST GAMMA Polymer Distribution Line Post provide superior support and electrical insulation on overhead distribution lines, conductor jumpers or leads. They can be installed horizontally or vertically on metal, concrete or wooden structures. The core of the insulator is made of a corrosion resistant epoxy resin fiberglass rod constructed exclusively for electrical and mechanical applications. Housing and sheds consist of a one-piece injection molded composite material that chemically bonds to the core rod. This creates a water-tight seal between the polymer and the rod that is impervious to moisture penetration. The composite material itself is made of silicone rubber with additives to enhance performance in contaminated environments and under a variety of conditions such as rain, ice, sand and salt. The line end of GAMMA s Polymer Line Post Insulator is available in two configurations: Hot Dip Galvanized Iron Casting or Porcelain. The porcelain end fitting provides superior leakage distance and reduced unit weight. Both are sealed to prevent water from penetrating to the fiberglass core GAMMA Polymer Line Post are designed, manufactured and tested according to ANSI standard C Polymer Line Post Insulator for distribution PL015 PL015H PL028 PL028H PL035 PL035H PL046 PL046H Content
43 Polymer line post for distribution Hot dip galvanized Steel Ø2 4/5 R1 Porcelain Ø23 R 3/5 11/10 Ø1 7/10 1 1/10 2 3/ /10 Ø1 7/10 2 3/10 10 Ø3 Ø4 2/5 Ø5 3/5 Ø 3.0 Ø4 2/5 Ø5 3/5 PL015 STANDARD VERSION PL015H *HYBRID VERSION CATALOG NUMBER ANSI (C29.18) Class Neck type CRITICAL DISTANCES, inches Arcing distance Leakage distance MECHANICAL VALUES, Lb SCL Maximum density cantilever load Tensile strength ELECTRICAL VALUES,kV Rated voltage Low-frequency dry flashover Low-frequency wet flashover Critical impulse flashover, positive Critical impulse flashover, negative PL F F 6 1/2 13 7/10 5,000 1,348 5, PL015H 6 3/4 14 7/10 3,000 1,348 3, RADIO INFLUENCE VOLTAGE DATA Low-frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv DIMENSIONS ACCORDING TO DRAWING Center hole nominal thread size Note1: Dimensions in inches. * Combines a ceramic head and silicone elastomer housing properties superior leakage distance and reduced unit weight. Housing: High voltage silicone - High temperature vulcanized (HTV). Fittings: Hot dip galvanized steel / /4
44 Polymer line post for distribution Hot dip galvanized Steel Ø 2 4/5 R 1 Porcelain Ø2 3/10 Ø7/10 Ø1 4/5 13 7/10 Ø7/10 Ø2 4/5 Ø2 3/ /5 Ø2 3/10 Ø3 Ø 4 2/5 Ø5 1/5 Ø3 Ø 4 2/5 Ø5 1/5 PL028 STANDARD VERSION PL028H *HYBRID VERSION CATALOG NUMBER ANSI (C29.18) Class Neck type CRITICAL DISTANCES, inches Arcing distance Leakage distance PL F F 8 4/5 22 PL028H 9 7/ /5 MECHANICAL VALUES, Lb SCL Maximum density cantilever load Tensile strength ELECTRICAL VALUES,kV Rated voltage Low-frequency dry flashover Low-frequency wet flashover Critical impulse flashover, positive Critical impulse flashover, negative RADIO INFLUENCE VOLTAGE DATA Low-frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv DIMENSIONS ACCORDING TO DRAWING Center hole nominal thread size 5,000 1,348 5,000 3,000 1,348 3,000 Note1: Dimensions in inches. * Combines a ceramic head and silicone elastomer housing properties superior leakage distance and reduced unit weight. Housing: High voltage silicone - High temperature vulcanized (HTV). Fittings: Hot dip galvanized steel / /4
45 Polymer line post for distribution Hot dip galvanized Steel Ø 2 4/5 R 1 Porcelain Ø2 3/10 R3/5 Ø7/10 1 4/5 2 3/10 Ø 7/10 1 4/5 2 3/ / /5 Ø3 Ø4 2/5 Ø5 3/5 PL035 STANDARD VERSION Ø3 Ø4 2/5 Ø5 3/5 PL035H *HYBRID VERSION CATALOG NUMBER ANSI (C29.18) Class Neck type CRITICAL DISTANCES, inches Arcing distance Leakage distance PL F F 11 1/5 30 1/4 PL035H 11 9/ /4 MECHANICAL VALUES, Lb SCL Maximum density cantilever load Tensile strength ELECTRICAL VALUES,kV Rated voltage Low-frequency dry flashover Low-frequency wet flashover Critical impulse flashover, positive Critical impulse flashover, negative RADIO INFLUENCE VOLTAGE DATA Low-frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv DIMENSIONS ACCORDING TO DRAWING Center hole nominal thread size 5,000 1,348 5,000 Note1: Dimensions in inches. * Combines a ceramic head and silicone elastomer housing properties superior leakage distance and reduced unit weight. Housing: High voltage silicone - High temperature vulcanized (HTV). Fittings: Hot dip galvanized steel /4 3,000 1,348 3, /4
46 Polymer line post for distribution Hot dip galvanized Steel Ø2 4/5 R1 Porcelain Ø2 4/5 R3/5 Ø1 7/10 1 1/ /5 Ø7/10 1 1/ /5 2 3/10 2 3/10 CATALOG NUMBER ANSI (C29.18) Class Neck type Ø3 Ø 4 2/5 Ø5 3/5 PL046 STANDARD VERSION CRITICAL DISTANCES, inches Arcing distance Leakage distance Ø3 Ø 4 2/5 Ø5 3/5 PL046H *HYBRID VERSION PL F F 13 3/5 38 1/2 PL046H 13 15/ /16 MECHANICAL VALUES, Lb SCL Maximum density cantilever load Tensile strength ELECTRICAL VALUES,kV Rated voltage Low-frequency dry flashover Low-frequency wet flashover Critical impulse flashover, positive Critical impulse flashover, negative RADIO INFLUENCE VOLTAGE DATA Low-frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv DIMENSIONS ACCORDING TO DRAWING Center hole nominal thread size 5,000 1,348 5,000 Note1: Dimensions in inches. * Combines a ceramic head and silicone elastomer housing properties superior leakage distance and reduced unit weight. Housing: High voltage silicone - High temperature vulcanized (HTV). Fittings: Hot dip galvanized steel /4 3,000 1,348 3, /4
47 Clamp top
48 Clamp top insulators are designed and manufactured according to ANSI C29.7, to ensure both electrical and mechanical performance. These characteristics satisfy all dimensional specifications and applicable requirements. GAMMA offers vertical type clamp tops, as well as cup base and gain base horizontal type for voltages ranging from 20kV to 45kV for distribution lines. Clamp tops can be assembled in wood or metallic cross arms, concrete posts or metallic structures. Clamp top vertical type Clamp top horizontal cup base type
49 Clamp top 5/8-11 NC 5/8-11 NC 5 13/16 9 5/16 6 1/ /64 3/4-10 UF /4-10 UF /8-11 NC 5/8-11 NC 6 5/8 6 3/8 14 5/ / /4-10 UF 3/4-10 UF CATALOG NUMBER ANSI CLASS (C rev. 2002) CRITICAL DISTANCES, inches Dry arcing distance Leakage distance MECHANICAL VALUES, pounds Cantilever strength Tensión strength ELECTRICAL VALUES, kv Typical application voltage Low-frequency dry flashover Low-frequency wet flashover Critical impulse flashover, positive RADIO INFLUENCE VOLTAGE DATA Low-frequency test voltage, RMS to ground, kv Maximum RIV at 1000 khz, μv Note 1: ANSI 70 gray is standard. Brown available by request Note 2: LN = Lock nut / LNC= Lock nut with trunnion bolt Note 3: Available with short or long stud, sold separately LN LNC LN LNC LN LNC LN LNC
50 Clamp top Horizontal cup Base type Note 1: Note 2: Note 3:
51 Ø 6 1/8 Ø19/32 Clamp top Horizontal gain Base type 5/8-11 NC 5/8-11 NC 11 13/ /8 Ø 7/ /16 5/8-11 NC 5/8-11 NC 11 13/16 Ø7/8 Ø6 3/8" 11 13/16 Ø7/ /16" 17 13/64" /16 Note 1: Note 2:
52 Station post INSULATORS
53 Station post station post The GAMMA and GAMMA-CERISOL brand of ANSI solid core porcelain station-post are ideally suited for substation bus support and switch applications. Station posts in this catalog are available in standard strength, high strength, and extra high strength, in ratings from 95kV BIL through 1800kV BIL, and for applications ranging from 7.5kV through 500kV operating voltages. Each insulator body is molded from the highest quality raw materials produced in our state-of-the-art mineral processing facilities, yielding a product of exceptional wet process workability, purity, and uniformity. The entire surface of each station post receives a smooth, uniform glaze, in either gray or brown, to provide maximum mechanical porcelain strength, to resist the accumulation of contaminants on the surface, and to facilitate ease of cleaning via rain or routine maintenance. In addition, the product line features uniform surface drying and voltage distribution to prevent flashover as well as dry-band arc suppression for high performance and long term reliability. All hardware fittings are manufactured using hot dipped galvanized malleable cast iron or ductile cast iron, and are designed specifically for all mechanical and electrical applications to ensure optimum performance and service longevity. Portland base mortar is used to secure the hardware to the porcelain body using a proven system that transfers the load uniformly from the hardware into the porcelain body. A bituminous coating is applied on the porcelain and the interior of the fittings to compensate for thermal expansion in extreme weather applications. Station post type, 95kV BIL Station post type, 110kV BIL 202SU HU SU HU0110 Station post type, 750kV BIL Station post type, 900kV BIL 291SU HU SU HT HU0900 Small station post Station post type, 150kV BIL Station post type, 200kV BIL Station post type, 250kV BIL 208SU HU SU HU SU HU0250 Station post type, 1050kV BIL Station post type, 1300kV BIL 312ST SU HT HU EU ST SU HT EU ET1300 Station post type, 350kV BIL Station post type, 550kV BIL Station post type, 650kV BIL 216SU HU SU HU SU HU0650 Station post type, 1470kV BIL Station post type, 1550kV BIL Station post type, 1800kV BIL 330SU HT EU ET HT ST1800 Content
54 STATION POST INSULATORS Sheds Sheds are designed to provide excellent electrical insulation under highly contaminated conditions, and are strong enough to provide protection against mechanical intrusion. If the shed does break, it is designed to break cleanly, leaving the body undamaged and the insulator serviceable. In addition, our station post insulators utilize sheds that, when accompanied with adequate angle and radius geometry, will ensure the best protection against rain and pollution. 100% Solid Core Porcelain Body Each insulator body is molded from the highest quality raw materials produced in our state-of-the-art mineral processing facilities, yielding a product of exceptional wet process workability, purity, and uniformity. Hardware All our Station Post hardware fittings are manufactured using hot dipped galvanized malleable cast iron or ductile cast iron. Are designed specifically for all mechanical and electrical applications to ensure optimum performance and service longevity. Glaze The entire surface of each Station Post receives a smooth, uniform glaze in either gray or brown to provide maximum mechanical porcelain strength, to resist the accumulation of contaminants on the surface, and to facilitate ease of cleaning via rain or routine maintenance. Cementing With Portland base mortar, hardware fittings are cemented to the porcelain body using a proven system that transfers the load uniformly from the hardware into the porcelain body. A bituminous coating is applied on the porcelain and the interior of the fittings to compensate for thermal expansion in extreme weather applications. World class manufacturing facilities and engineering expertise, along with in-house tooling and development capabilities, give us the ability and skill set required to produce custom designed station posts for a wide variety of applications and customer specifications. Experience the GAMMA Difference!
55 Station-post Type, 95 kv BIL 4 Threads Ø1/2" Threads Ø5/8" /2" 10" 3" Ø4 1/4" Ø7" TR-202 STANDARD STRENGTH UNIT 5" Ø6.25" Ø7.24" TR-222 HIGH STRENGTH UNIT CATALOG NUMBER 202SU HU0095 ANSI CLASS C (R2002, R2012) TR-202 TR-222 CRITICAL DISTANCES, inches Leakage distance 10 1/2 10 1/2 MECHANICAL VALUES, pounds Cantilever strength, upright Cantilever strength, underhung Tensile strength Torsion strength, inch-pounds Compression strength ELECTRICAL VALUES, kv Typical application voltage Impulse flashover, positive Low frequency withstand, 10 sec. wet Impulse withstand RADIO - INFLUENCE VOLTAGE Low frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv Note 1: ANSI 70 gray is standard. Brown available by request. Note 2: can be ordered with M12 thread size. Contact your GAMMA sales representative for additional information
56 Station-post Type, 110 kv BIL 4 Threads Ø 1/2" Threads Ø 5/8" " 12" 3" 5" Ø4 1/4" Ø6.25" Ø7" Ø7.24" TR-205 STANDARD STRENGTH UNIT TR-225 HIGH STRENGTH UNIT CATALOG NUMBER 205SU HU0110 ANSI CLASS C (R2002, R2012) TR-205 TR-225 CRITICAL DISTANCES, inches Leakage distance 15 1/2 15 1/2 MECHANICAL VALUES, pounds Cantilever strength, upright Cantilever strength, underhung Tensile strength Torsion strength, inch-pounds Compression strength ELECTRICAL VALUES, kv Typical application voltage Impulse flashover, positive Low frequency withstand, 10 sec. wet Impulse withstand RADIO - INFLUENCE VOLTAGE Low frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv Note 1: ANSI 70 gray is standard. Brown available by request. Note 2: can be ordered with M12 thread size. Contact your GAMMA sales representative for additional information
57 Station-post Type, 150 kv BIL 4 Threads Ø 1/2" Threads Ø 5/8" " 15" 3" Ø4 1/4" Ø6 1/2" 5" Ø6.31" Ø8.46" TR-208 STANDARD STRENGTH UNIT TR-227 HIGH STRENGTH UNIT CATALOG NUMBER 208SU HU0150 ANSI CLASS C (R2002, R2012) CRITICAL DISTANCES, inches TR-208 TR-227 Leakage distance MECHANICAL VALUES, pounds Cantilever strength, upright Cantilever strength, underhung Tensile strength Torsion strength, inch-pounds Compression strength ELECTRICAL VALUES, kv Typical application voltage Impulse flashover, positive Low frequency withstand, 10 sec. wet Impulse withstand RADIO - INFLUENCE VOLTAGE Low frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv Note 1: ANSI 70 gray is standard. Brown available by request. Note 2: can be ordered with M12 thread size. Contact your GAMMA sales representative for additional information
58 Station-post Type, 200 kv BIL 4 Threads Ø 1/2" Threads Ø 5/8" " 20" 3" 5" Ø4 1/4" Ø6.31" Ø7 1/2" Ø8.58" TR-210 STANDARD STRENGTH UNIT TR-231 HIGH STRENGTH UNIT CATALOG NUMBER 210SU HU0200 ANSI CLASS C (R2002, R2012) CRITICAL DISTANCES, inches TR-210 TR-231 Leakage distance MECHANICAL VALUES, pounds Cantilever strength, upright Cantilever strength, underhung Tensile strength Torsion strength, inch-pounds Compression strength ELECTRICAL VALUES, kv Typical application voltage Impulse flashover, positive Low frequency withstand, 10 sec. wet Impulse withstand RADIO - INFLUENCE VOLTAGE Low frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv Note 1: ANSI 70 gray is standard. Brown available by request. Note 2: can be ordered with M12 thread size. Contact your GAMMA sales representative for additional information
59 Station-post Type, 250 kv BIL 4 Threads Ø 1/2" Threads Ø 5/8" " 24" 3" Ø4 1/4" Ø7" 5" Ø6.31" Ø8.74" TR-214 STANDARD STRENGTH UNIT TR-267 HIGH STRENGTH UNIT CATALOG NUMBER 214SU HU0250 ANSI CLASS C (R2002, R2012) CRITICAL DISTANCES, inches TR-214 TR-267 Leakage distance MECHANICAL VALUES, pounds Cantilever strength, upright Cantilever strength, underhung Tensile strength Torsion strength, inch-pounds Compression strength ELECTRICAL VALUES, kv Typical application voltage Impulse flashover, positive Low frequency withstand, 10 sec. wet Impulse withstand RADIO - INFLUENCE VOLTAGE Low frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv Note 1: ANSI 70 gray is standard. Brown available by request. Note 2: can be ordered with M12 thread size. Contact your GAMMA sales representative for additional information
60 Station-post Type, 350 kv BIL 4 Threads Ø1/2" Threads Ø 5/8" " 30" 3" Ø4 1/4" Ø8.1" 5" Ø6.3" Ø9.1" TR-216 STANDARD STRENGTH UNIT TR-278 HIGH STRENGTH UNIT CATALOG NUMBER 216SU HU0350 ANSI CLASS C (R2002, R2012) CRITICAL DISTANCES, inches TR-216 TR-278 Leakage distance MECHANICAL VALUES, pounds Cantilever strength, upright Cantilever strength, underhung Tensile strength Torsion strength, inch-pounds Compression strength ELECTRICAL VALUES, kv Typical application voltage Impulse flashover, positive Low frequency withstand, 10 sec. wet Impulse withstand RADIO - INFLUENCE VOLTAGE Low frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv Note 1: ANSI 70 gray is standard. Brown available by request. Note 2: can be ordered with M12 thread size. Contact your GAMMA sales representative for additional information
61 Station-post Type, 550 kv BIL 4 Tapped holes Ø 5/8" - 11UNC 4 Tapped holes Ø 5/8" - 11UNC CATALOG NUMBER Ø6.22 Ø8.46 TR-286 STANDARD STRENGTH UNIT Ø6.3 Ø9.4 TR-287 HIGH STRENGTH UNIT 286SU HU0550 ANSI CLASS C (R2002, R2012) CRITICAL DISTANCES, inches TR-286 TR-287 Leakage distance MECHANICAL VALUES, pounds Cantilever strength, upright Cantilever strength, underhung Tensile strength Torsion strength, inch-pounds Compression strength ELECTRICAL VALUES, kv Impulse flashover, positive Low frequency withstand, 10 sec. wet Impulse withstand RADIO - INFLUENCE VOLTAGE Low frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv DIMENSIONS ACCORDING Sheds Note 1: ANSI 70 gray is standard. Brown available by request. Note 2: can be ordered with M16 thread size if 5/8-11UNC diameter. Contact your GAMMA sales representative for additional information
62 Station-post Type, 650 kv BIL 4 Tapped holes Ø 5/8" - 11UNC 4 Tapped holes Ø 5/8" - 11UNC Ø6.22 Ø8.46 TR-288 STANDARD STRENGTH UNIT Ø6.3 Ø9.1 TR-289 HIGH STRENGTH UNIT CATALOG NUMBER 288SU HU0650 ANSI CLASS C (R2002, R2012) CRITICAL DISTANCES, inches TR-288 TR-289 Leakage distance MECHANICAL VALUES, pounds Cantilever strength, upright Cantilever strength, underhung Tensile strength Torsion strength, inch-pounds Compression strength ELECTRICAL VALUES, kv Impulse flashover, positive Low frequency withstand, 10 sec. wet Impulse withstand RADIO - INFLUENCE VOLTAGE Low frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv DIMENSIONS ACCORDING Sheds Note 1: ANSI 70 gray is standard. Brown available by request. Note 2: can be ordered with M16 thread size if 5/8-11UNC diameter. Contact your GAMMA sales representative for additional information
63 Station-post Type, 750 kv BIL 4 Tapped holes Ø 5/8" - 11UNC 4 Tapped holes Ø 5/8" - 11UNC CATALOG NUMBER Ø6.22 Ø8.78 TR-291 STANDARD STRENGTH UNIT Ø6.3 Ø9.53 TR-295 HIGH STRENGTH UNIT 291SU HU0750 ANSI CLASS C (R2002, R2012) CRITICAL DISTANCES, inches TR-291 TR-295 Leakage distance MECHANICAL VALUES, pounds Cantilever strength, upright Cantilever strength, underhung Tensile strength Torsion strength, inch-pounds Compression strength ELECTRICAL VALUES, kv Impulse flashover, positive Low frequency withstand, 10 sec. wet Impulse withstand RADIO - INFLUENCE VOLTAGE Low frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv DIMENSIONS ACCORDING Sheds Note 1: ANSI 70 gray is standard. Brown available by request. Note 2: can be ordered with M16 thread size if 5/8-11UNC diameter. Contact your GAMMA sales representative for additional information
64 Station-post Type, 900 kv BIL 4 Tapped holes Ø 5/8" - 11UNC 4 Tapped holes Ø 5/8" - 11UNC 4 Tapped holes Ø 5/8" - 11UNC UNIT 1 UNIT 1 UNIT Ø UNIT 2 UNIT 2 UNIT Ø6.22 Ø8.39 Ø6.3 Ø9.33 Ø6.3 Ø9.33 TR-304 TR-308 HT TR-308 HU STANDARD STRENGTH UNIT HIGH STRENGTH UNIT EXTRA - HIGH STRENGTH UNIT CATALOG NUMBER 304SU HT HU0900 ANSI CLASS C (R2002, R2012) TR-304 CRITICAL DISTANCES, inches Leakage distance MECHANICAL VALUES, pounds Cantilever strength, upright Cantilever strength, underhung Tensile strength Torsion strength, inch-pounds Compression strength ELECTRICAL VALUES, kv Impulse flashover, positive Low frequency withstand, 10 sec. wet Impulse withstand RADIO - INFLUENCE VOLTAGE Low frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv DIMENSIONS ACCORDING Sheds unit 1 Sheds unit Note 1: ANSI 70 gray is standard. Brown available by request. Note 2: can be ordered with M16 thread size if 5/8-11UNC diameter. Contact your GAMMA sales representative for additional information. TR-308 TR
65 Station-post Type, 1050 kv BIL 4 Tapped holes Ø 5/8" - 11UNC 4 Tapped holes Ø 5/8" - 11UNC UNIT 1 UNIT UNIT 2 UNIT Ø6.22 Ø8.46 TR-312 ST STANDARD STRENGTH UNIT Ø6.22 Ø8.46 TR-312 SU STANDARD STRENGTH UNIT CATALOG NUMBER ANSI CLASS C (R2002, R2012) CRITICAL DISTANCES, inches Leakage distance MECHANICAL VALUES, pounds Cantilever strength, upright Cantilever strength, underhung Tensile strength Torsion strength, inch-pounds Compression strength ELECTRICAL VALUES, kv Impulse flashover, positive Low frequency withstand, 10 sec. wet Impulse withstand RADIO - INFLUENCE VOLTAGE Low frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv DIMENSIONS ACCORDING Sheds unit 1 Sheds unit 2 Note 1: ANSI 70 gray is standard. Brown available by request. Note 2: can be ordered with M16 thread size if 5/8-11UNC diameter. Contact your GAMMA sales representative for additional information. 312ST1050 TR SU1050 TR
66 Station-post Type, 1050 kv BIL 4 Tapped holes Ø 5/8" - 11UNC 4 Tapped holes Ø 5/8" - 11UNC 4 Tapped holes Ø 3/4" - 11UNC UNIT 1 UNIT 1 UNIT Ø8.98 Ø UNIT 2 UNIT 2 UNIT Ø6.3 Ø9.41 TR-316 HT HIGH STRENGTH UNIT Ø6.3 Ø9.41 TR-316 HU HIGH STRENGTH UNIT Ø8.66 Ø10.43 TR-362 EU EXTRA - HIGH STRENGTH UNIT CATALOG NUMBER 316HT HU EU1050 ANSI CLASS C (R2002, R2012) CRITICAL DISTANCES, inches Leakage distance MECHANICAL VALUES, pounds Cantilever strength, upright Cantilever strength, underhung Tensile strength Torsion strength, inch-pounds Compression strength ELECTRICAL VALUES, kv Impulse flashover, positive Low frequency withstand, 10 sec. wet Impulse withstand RADIO - INFLUENCE VOLTAGE Low frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv DIMENSIONS ACCORDING Sheds unit 1 Sheds unit 2 TR Note 1: ANSI 70 gray is standard. Brown available by request. Note 2: can be ordered with M16 thread size if 5/8-11UNC diameter. Note 3: can be ordered with M20 thread size if 3/4-10UNC diameter. Contact your GAMMA sales representative for additional information. TR TR
67 Station-post Type, 1300 kv BIL 4 Tapped holes Ø 5/8" - 11UNC 4 Tapped holes Ø 5/8" - 11UNC UNIT 1 UNIT Ø UNIT 2 UNIT Ø6.3 Ø9.06 TR-324 ST STANDARD STRENGTH UNIT Ø6.3 Ø9.06 TR-324 SU STANDARD STRENGTH UNIT CATALOG NUMBER ANSI CLASS C (R2002, R2012) CRITICAL DISTANCES, inches Leakage distance MECHANICAL VALUES, pounds Cantilever strength, upright Cantilever strength, underhung Tensile strength Torsion strength, inch-pounds Compression strength ELECTRICAL VALUES, kv Impulse flashover, positive Low frequency withstand, 10 sec. wet Impulse withstand RADIO - INFLUENCE VOLTAGE Low frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv DIMENSIONS ACCORDING Sheds unit 1 Sheds unit 2 324ST1300 TR Note 1: ANSI 70 gray is standard. Brown available by request. Note 2: can be ordered with M16 thread size if 5/8-11UNC diameter. Contact your GAMMA sales representative for additional information SU1300 TR
68 Station-post Type, 1300 kv BIL 4 Tapped holes Ø 5/8" - 11UNC Ø Tapped holes Ø 3/4" - 11UNC 4 Tapped holes Ø 5/8" - 11UNC Ø8.66 UNIT 1 UNIT 1 UNIT Ø8.46 Ø10.04 Ø UNIT 2 UNIT 2 UNIT Tapped holes Ø 3/4" - 11UNC Ø8.66 Ø10.04 TR-367 HT HIGH STRENGTH UNIT Ø8.66 Ø10.43 TR-368 EU EXTRA - HIGH STRENGTH UNIT 4 Tapped holes Ø 3/4" - 11UNC Ø8.66 Ø10.43 TR-369 ET EXTRA - HIGH STRENGTH UNIT CATALOG NUMBER 367HT EU ET1300 ANSI CLASS C (R2002, R2012) TR-367 TR-368 CRITICAL DISTANCES, inches Leakage distance MECHANICAL VALUES, pounds Cantilever strength, upright Cantilever strength, underhung 2050 Tensile strength Torsion strength, inch-pounds Compression strength ELECTRICAL VALUES, kv Impulse flashover, positive Low frequency withstand, 10 sec. wet Impulse withstand RADIO - INFLUENCE VOLTAGE Low frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv DIMENSIONS ACCORDING Sheds unit 1 Sheds unit Note 1: ANSI 70 gray is standard. Brown available by request. Note 2: can be ordered with M16 thread size if 5/8-11UNC diameter. Note 3: can be ordered with M20 thread size if 3/4-10UNC diameter. Contact your GAMMA sales representative for additional information TR
69 Station-post Type, 1470 kv BIL 4 Tapped holes Ø 5/8" - 11UNC 4 Tapped holes Ø 5/8" - 11UNC Ø Tapped holes Ø 3/4" - 11UNC Ø6.3 4 Tapped holes Ø 5/8" - 11UNC UNIT 1 UNIT 1 UNIT 1 UNIT Ø8.78 Ø10.24 Ø UNIT 2 UNIT 2 UNIT 2 UNIT Ø6.3 Ø Tapped holes Ø 3/4" - 11UNC Ø8.66 Ø9.72 Ø8.66 Ø Tapped holes Ø 3/4" - 11UNC Ø8.66 Ø10.32 TR-330 SU TR-371 HT TR-372 EU TR-373 ET STANDARD STRENGTH UNIT HIGH STRENGTH UNIT EXTRA - HIGH STRENGTH UNIT EXTRA - HIGH STRENGTH UNIT CATALOG NUMBER 330SU HT EU ET1470 ANSI CLASS C (R2002, R2012) TR-373 CRITICAL DISTANCES, inches Leakage distance MECHANICAL VALUES, pounds Cantilever strength, upright Cantilever strength, underhung Tensile strength Torsion strength, inch-pounds Compression strength ELECTRICAL VALUES, kv Impulse flashover, positive Low frequency withstand, 10 sec. wet Impulse withstand RADIO - INFLUENCE VOLTAGE Low frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv TR TR TR DIMENSIONS ACCORDING Sheds unit Sheds unit Note 1: ANSI 70 gray is standard. Brown available by request. Note 2: can be ordered with M16 thread size if 5/8-11UNC diameter. Note 3: can be ordered with M20 thread size if 3/4-10UNC diameter. Contact your GAMMA sales representative for additional information
70 Station-post Type, 1550 kv BIL Ø6.3 4 Tapped holes Ø 5/8" - 11UNC UNIT Ø UNIT 2 Ø CATALOG NUMBER 4 Tapped holes Ø 3/4" - 11UNC Ø8.66 Ø10.83 TR-379 HT HIGH STRENGTH UNIT 379HT1550 ANSI CLASS C (R2002, R2012) TR-379 CRITICAL DISTANCES, inches Leakage distance 280 MECHANICAL VALUES, pounds Cantilever strength, upright Tensile strength Torsion strength, inch-pounds Compression strength ELECTRICAL VALUES, kv Impulse flashover, positive Low frequency withstand, 10 sec. wet Impulse withstand RADIO - INFLUENCE VOLTAGE Low frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv DIMENSIONS ACCORDING Sheds unit 1 Sheds unit 2 Note 1: ANSI 70 gray is standard. Brown available by request. Note 2: can be ordered with M16 thread size if 5/8-11UNC diameter. Contact your GAMMA sales representative for additional information
71 Station-post Type, 1800 kv BIL 4 Tapped holes Ø 5/8" - 11UNC Ø6.69 UNIT 1 Ø UNIT 2 Ø UNIT 3 Ø CATALOG NUMBER 4 Tapped holes Ø 3/4" - 11UNC Ø8.66 Ø10.83 TR-391 ST HIGH STRENGTH UNIT 391ST1800 ANSI CLASS C (R2002, R2012) TR-391 CRITICAL DISTANCES, inches Leakage distance MECHANICAL VALUES, pounds Cantilever strength, upright Tensile strength Torsion strength, inch-pounds Compression strength ELECTRICAL VALUES, kv Impulse flashover, positive Low frequency withstand, 10 sec. wet Impulse withstand RADIO - INFLUENCE VOLTAGE Low frequency test voltage, RMS to ground, kv Maximum RIV at 1,000 khz, μv DIMENSIONS ACCORDING Sheds unit 1 Sheds unit 2 Sheds unit 3 Note 1: ANSI 70 gray is standard. Brown available by request. Note 2: can be ordered with M16 thread size if 5/8-11UNC diameter. Contact your GAMMA sales representative for additional information
72 Small station post 3/8-16 Thread (Galv. Steel) TYP 3/8-16 Thread (Galv. Steel) TYP 3/8-16 Thread (Galv. Steel) TYP 6 3/4" 7" 8" 1" 2 1/4" Ø3 7/10" Ø5 1/2" 1" 2 1/4" Ø3 7/10" Ø5 1/2" 1" 2 1/4" Ø3 7/10" Ø5 1/2" /8-16 Thread (Galv. Steel) TYP 3/8-16 Thread (Galv. Steel) TYP 9" 10" 1" 2 1/4" Ø3 7/10" Ø5 1/2" 1" 2 1/4" Ø3 7/10" Ø5 1/2" CATALOG NUMBER CRITICAL DISTANCES, inches Leakage distance 13 9/ /4 17 1/2 20 7/8 24 3/8 MECHANICAL VALUES, pounds Cantilever strength, pounds Tensile strength, pounds Torsion strenght, inch-pounds Compression strenght, pounds ELECTRICAL VALUES, kv Low-frequency withstand, 10 sec. wet Basic insulation level (BIL), kv Note: ANSI 70 gray is standard. Brown available by request.
73 Fiberglass guy strain
74 Fiberglass guy strain type insulators are used in low and medium voltage lines. These are designed to work in mechanical tension (strain), to withstand the pull of a suspended electrical wire or cable. They are used in overhead electrical wiring to support radio antennas and overhead power lines. Fiberglass guy strains are manufactured using high quality raw materials to ensure a perfect connection between the fiberglass nucleus and cast ductile iron fittings. Fittings are designed to satisfy applicable mechanical and electrical requirements. Various combinations are available for distribution lines assemblies: Clevis, Y- clevis, roller and thimble eye, which resist mechanical loads ranging from 15,000 up to 36,000 lbs. Fiberglass guy strain, GS15 GS1512- XX GS1518- XX GS1524- XX GS1530- XX GS1536- XX GS1542- XX GS1554- XX GS1560- XX GS1578- XX GS1590- XX GS1596- XX GS15120-XX GS15144-XX Fiberglass guy strain, GS21 GS2112- XX GS2118- XX GS2124- XX GS2130- XX GS2136- XX GS2142- XX GS2154- XX GS2160- XX GS2178- XX GS2190- XX GS2196- XX GS21120-XX GS21144-XX Fiberglass guy strain, GS36 GS3612- XX GS3618- XX GS3624- XX GS3630- XX GS3636- XX GS3642- XX GS3654- XX GS3660- XX GS3678- XX GS3690- XX GS3696- XX GS36120-XX GS36144-XX Content
75 Fiberglass guy strain GS15 - Series L 0.6 GM GM L ASSEMBLY RL STICK CATALOG NUMBER MECHANICAL STRENGTH CLASS, Lbs (KN) LENGTH L, inches (mm) GS1512- XX GS1518- XX GS1524- XX GS1530- XX GS1536- XX GS1542- XX GS1554- XX GS1560- XX GS1578- XX GS1590- XX GS1596- XX GS15120-XX GS15144-XX Note 1: XX code is the type of cast ductile iron, hot dip galvanized end fittings. T: Thimble Eye Y: Y - Clevis C: Clevis with pin and clip R: Clevis with roller pin and clip Example: TC (Thimble eye - Clevis with pin and clip) end (67) 12" (305) (67) 18" (457) (67) 24" (610) (67) 30" (762) (67) 36" (914) (67) 42" (1067) (67) 54" (1372) (67) 60" (1524) (67) 78" (1981) (67) 90" (2286) (67) 96" (2438) (67) 120" (3048) (67) 144" (3657)
76 Fiberglass guy strain GS21 - Series L GM GM L ASSEMBLY 0.75 RL STICK CATALOG NUMBER MECHANICAL STRENGTH CLASS, Lbs (KN) LENGTH L, inches (mm) GS2112- XX GS2118- XX GS2124- XX GS2130- XX GS2136- XX GS2142- XX GS2154- XX GS2160- XX GS2178- XX GS2190- XX GS2196- XX GS21120-XX GS21144-XX Note 1: XX code is the type of cast ductile iron, hot dip galvanized end fittings. T: Thimble Eye Y: Y - Clevis C: Clevis with pin and clip R: Clevis with roller pin and clip Example: TC (Thimble eye - Clevis with pin and clip) end (95) 12" (305) (95) 18" (457) (95) 24" (610) (95) 30" (762) (95) 36" (914) (95) 42" (1067) (95) 54" (1372) (95) 60" (1524) (95) 78" (1981) (95) 90" (2286) (95) 96" (2438) (95) 120" (3048) (95) 144" (3657)
77 Fiberglass guy strain GS36 - Series L 0.8 GM GM L ASSEMBLY RL STICK CATALOG NUMBER MECHANICAL STRENGTH CLASS, Lbs (KN) LENGTH L, inches (mm) GS3612- XX GS3618- XX GS3624- XX GS3630- XX GS3636- XX GS3642- XX GS3654- XX GS3660- XX GS3678- XX GS3690- XX GS3696- XX GS36120-XX GS36144-XX Note 1: XX code is the type of cast ductile iron, hot dip galvanized end fittings. T: Thimble Eye C: Clevis with pin and clip R: Clevis with roller pin and clip Example: TC (Thimble eye - Clevis with pin and clip) end (160) 12" (305) (160) 18" (457) (160) 24" (610) (160) 30" (762) (160) 36" (914) (160) 42" (1067) (160) 54" (1372) (160) 60" (1524) (160) 78" (1981) (160) 90" (2286) (160) 96" (2438) (160) 120" (3048) (160) 144" (3657)
78 Hardware
79 Hardware For The Product: Designed to eliminate abrupt changes in curvature, our high quality finished products, relies on smooth surfaces, with no sharp edges, protusions, burrs, slag or scales. These designs, avoids points of mechanical stress concentration or electric field, and possible radio interface signal. The Galvanized: Galvanized hardware to ensure proper protection from corrosion and contaminant elements. We also offer double galvanized hardware in order to potentiate those features, especially when these are going to be installed in contaminated environments, overall, with our polymer dead end insulators. Standards as applicable: ANSI C135.17: 1979 pin studs ASTM D-4066 nylon threads ASTM A-536 Class for nodular steel IEEE std C for clamps Constitutive Parts: Clamps are of aluminum alloy 356 and T6 type heat treatment. The product provides excellent mechanical properties resulting from the use of aluminum alloy of high conductivity, giving, simultaneously, high resistance to corrosion. Stainless steel cotter pins. Provides security in the assembly, in the way that the pin material has high corrosion resistance and excellent mechanical properties, therefore, ensures the mounting assembly. Hardwares Eye nuts Hangers Thimbles Clamps Couplings Mounting Studs nylon thread Mounting studs Content
80 Hardware Guide for insulators usage Suspensions CH645 CH651 Hanging Rings Post Mount CH627 Polymers CH607 Eye Nuts CH631 Casting ASTM 536 hot dip galvanized GAMMA Cable Mount ANSI 52-9 A CH657 Thimble CH013GRP1 CH017GRP1 CH017GRR1 CH012GRR1 Clamps Aluminum 356 treatment T6 CH017GSS1 CH645 CH651 Hanging Rings Post Mount CH657 Thimble CH627 CH607 Eye Nuts CH631 Cable Mount Casting ASTM 536 hot dip galvanized Couplings for Porcelain and Polymers GAMMA PS015 PS025 PS035 PS045 PS069 ANSI DS-15 DS-28 DS-35 DS-46 DS-69 CH013GRP1 CH017GRP1 CH017GRR1 CH012GRR1 Clamps Aluminum 356 treatment T6 CH017GSS1 Post Mount CH620 Ball Clevis CH638 Eye Ball GAMMA Cable Mount ANSI CH623 Socket Tongue Casting ASTM 536 hot dip galvanized Cable Mount GAMMA ANSI CH630 Clevis Tongue CH620 Ball Clevis
81 Eye nuts Hardware Ø6/10 3 Ø15/10 16/10 Thread 5/8-11UNC-2B 8/10 13/10 11/10 Ø16/10 26/10 6/10 Ø7/10 Ø6/10 44/10 5/8 33/10 45/10 28/10 Thread 5/8-11UNC-2B Thread 5/8-11UNC-2B 7/10 11/10 6/10 Ø25/10 Ø14/10 28/10
82 Hangers Hardware Ø26/10 Ø5/8 5/8 Ø13/10 35/10 39/10 7/10 Ø17/10 5/8 Ø16/10 7/ /10 Ø3/10 27/10 Ø3/10 Ø5/8 32/10 Ø5/8 32/10
83 Thimble Hardware 16/10 17/10 9/10 Ø7/10 Ø2/10 Ø5/8 23/10 31/10 52/ /10 16/10 3
84 Clamps Hardware 1 1 A Ø5/8 7 B 11/ C 6 5/ /10 B A C Deadend clamp Quadrant deadend clamp RAW MATERIAL 1. Aluminum alloy T6 2. Aluminum alloy T6 3. Galvanized steel U-bolts 4. Galvanized steel U-bolts 5. Galvanized steel U-bolts 6. Galvanized forged steel 7. Stainless steel
85 Clamps Hardware B Ø5/8 11/4 1 Quadrant deadend clamp 7 A 1 Ø5/8 C / B 6 2 C 5/8 4 1 B A Deadend clamp RAW MATERIAL 1. Aluminum alloy T6 2. Aluminum alloy T6 3. Galvanized steel U-bolts 4. Galvanized steel U-bolts 5. Galvanized steel U-bolts 6. Galvanized forged steel 7. Stainless steel
86 Couplings Hardware 1 1/2 7/8 1 1/2 Ø3/4 2 3/4 2 7/ /4 2 1/2 2 1/2 4 R3 4 Ø11/2 Ø11/16 1 1/2 1 1/2 R1/ /2 1 1 Ø1 1/2 2 Ø3 1/2 5 Ø1 1/16 Ø11/16 Ø3/4 Ø2 1/2 Ø1 1/2
87 Hardware for Pins Guide for insulators usage Pin Type GAMMA 6188R R-70 ANSI GAMMA 6183R R-70 ANSI Wood Crossarm Metal Crossarm Post Mount CH150EME1 CH150EMA1 CH150ECO1 Casting ASTM 536 Nylon thread Ø 1 ASTM D 4066 GAMMA R R-70 ANSI GAMMA 10435R R-70 ANSI Wood Crossarm Metal Crossarm Post Mount CH203EME1 CH203EMA1 CH203ECO1 Pin post Casting ASTM 536 Nylon Thread Ø 1 1/2 ASTM D 4066 GAMMA Wood Crossarm Metal Crossarm Post Mount CH150EME1 CH150EMA1 CH150ECO1 Casting ASTM 536 Nylon Thread Ø 1 1/2 ASTM D 4066
88 Mounting Studs Nylon Thread Nylon Thread Ø1 Ø9/10 Ø3/4 Ø2 1 3/4 A 6 B
89 Mounting Studs Nylon Thread Nylon Thread Ø1 3/8 Ø1 1/2 Ø1 Ø3 1/2 Ø3/4 2 1/8 A 8 B
90 Hardware for Posts Guide for insulators usage Tie Top GAMMA 9325X X X-70 ANSI GAMMA 8416X X-70 ANSI Metal Crossarm Wood Crossarm Wood Crossarm Metal Crossarm Metal Crossarm V A V A V V V Wrought hot dip galvanized Clamp top GAMMA ANSI GAMMA ANSI Metal Crossarm Wood Crossarm Wood Crossarm Metal Crossarm Metal Crossarm V A V A V V V Wrought hot dip galvanized
91 Mounting Studs 0.06 FLAT BEARING SURFACE A /4-10 3/4-10 Ø1.25 SERRATED SURFACE R A (25/32 ) HEX MUST PASS Ø0.81 HOLE SECTION A - A CATALOG NUMBER V A Dimensions in inches ACCESORIES 1 Med type positive lock washer 1 Square Washer 1 Standard square nut 1 Lock nut 3/4 2.25sq x 0.81 x /4 3/4 Notes: Wood crossarm Rating, kv: 35, 45, 55, 66 Material: C-1038 steel Minimum Brinnell 143 Hot dip galvanized
92 Mounting Studs A Ø1.25 3/4-10 5/ REF. SERRATED SURFACE 8.75 A 4.0 SECTION A - A CATALOG NUMBER V A Dimensions in inches ACCESORIES 1 Med type positive lock washer 1 Square Washer 1 Regular square nut 1 Lock nut 3/4 2 x 2 x 11/16 x 1/8 5/8 5/8 Notes: Wood crossarm Rating, kv: 15, 20, 25 Material: C-1038 steel Minimum Brinnell 143 Hot dip galvanized
93 Mounting Studs / Ø1.25 SERRATED SURFACE R / /8-11 NUT MUST PASS OVER HEX. CORNERS AFTER GALV MUST FIT 7/16 WRENCH CATALOG NUMBER V Dimensions in inches ACCESORIES 1 LT type positive lock washer 1 LT type positive lock washer 1 Square washer 1 Regular hexagonal nut 3/4 5/ x 2.25 x 0.69 x /8 Notes: Metal crossarm Rating, kv: 15,20, 25 Material: C-1038 steel Minimum Brinnell 143 Hot dip galvanized
94 GAMMA INSULATORS CORP. - TERMS & CONDITIONS OF SALE 1. AGREEMENT. The contract of sale resulting from documentation on the reverse side or attached hereto together with these terms and conditions ( Contract ) constitutes the entire agreement between the parties hereto, except as modified in writing signed by both the Seller and Purchaser. The Seller is Gamma Corp. and the Purchaser is identified in the Contract. Any terms in a purchase order, irrespective of their materiality, which are either different from or additional to Seller s terms and conditions of sale, are objected to and are excluded unless the Seller expressly agrees in writing to such terms. Execution of such forms by Seller to accommodate Purchaser s procedures or to evidence agreed upon change orders shall not be construed as assent to Purchaser s terms. Any representations, warranties or statements made by any employee, sales person or agent of Seller not expressed in the Contract shall not be binding on Seller. Acceptance of the goods shipped shall constitute assent to Seller s terms and conditions of sale. The Contract shall be binding upon Purchaser and Seller, and on their successors and assigns. 2. ACCEPTANCE AND APPROVAL OF ORDER. A proposal or quotation from Seller shall not be considered as an offer, but the basis for an order from Purchaser which is subject to acceptance by Seller. An order will become binding on Seller only when accepted and approved by the Sales and Credit Department of the Seller. Orders are accepted only at Rochester, New York and / or Sabaneta, Colombia. The minimum order is $500. Partial orders are subject to price reviews. Orders must be in even standard packages. In the event of an order that does not correspond to standard package size, Seller will increase the order quantity to the next largest standard package size. 3. CREDIT. Credit terms of payment must have the approval of Seller s Credit Department and must be specified in writing on Seller s invoice or in the Contract. If Purchaser s credit is found by Seller to be unsatisfactory, Seller may rescind or terminate the Contract. If at any time during the term of the Contract Purchaser s financial responsibility becomes impaired or unsatisfactory to Seller, Seller reserves the right to stop shipment on notification to Purchaser, demand payment in advance or at time of delivery for future deliveries, or require other security satisfactory to Seller and in the absence thereof, to terminate the unfilled portion of the Contract. Seller will notify Purchaser promptly of its decision to stop shipments and give an advance notice to the extent possible. In the absence of credit terms, sales are for cash. 4. PAYMENT. Default unless otherwise stated is Net 30 days in U.S. Funds. Specific terms of payment shall be set forth on the reverse side of the Contract or identified and appended hereto. Purchaser agrees to make payment at Seller s location specified in the Contract in lawful money of the United States. Purchaser further agrees to make all payments when due to Seller in accordance with the agreed terms of payment in the Contract with no right of retention or set-off. Purchaser agrees to pay a finance charge of 1.5% per month (or, to the extent permitted by law if less) on all delinquent balances if and when assessed by Seller, and any attorney s fees and court costs arising out of and made necessary in collection of Purchaser s obligation to Seller created by the Contract. 5. TAXES. Any federal, state or local tax, assessment, fee, duty or charge hereafter imposed on or measured by the products purchased hereunder shall be for Purchaser s account, unless Purchaser furnishes Seller an acceptable exemption certificate from such tax, fee, duty or charge prior to shipment. 6. FORCE MAJEURE. Seller shall make delivery in accordance with the terms of the Contract or within a reasonable time in the absence of any specific commitment, but Seller shall not be liable for delays or defaults in delivery caused by floods, fires, storms, or other acts of God, by war or act of public enemy (or civil disturbance), strikes, lockouts, shortages of labor or raw materials and supplies (including fuel) or production facilities, transportation service or equipment shortages or failures, action of any governmental authority or other conditions beyond Seller s reasonable control. 7. CANCELLATION. Order cancellations and/or deferrals will be subject to a minimum 25% charge. If Purchaser desires to cancel or change any portion of the Contract, it must make such request in writing to Seller. Seller may, in its sole discretion, accept or reject any such request. If accepted, the Purchaser nonetheless must take delivery and make payment to Seller for all material manufactured and in stock or in process of manufacture at time of notice, and all special materials ordered at time of notice and for which Seller must take delivery, unless otherwise agreed by Seller in writing. All such materials must be removed from Seller s premises within 30 days after payment and payment will be due at time of notice. 8. INSPECTION AND TESTING. Seller s standard specifications and tests apply to all orders. All charges for inspections or tests not regularly furnished are for Purchaser s account and subject to prior negotiation. All inspections shall be conducted at Seller s plant, and failure of Purchaser to avail itself of inspection privileges shall be deemed a waiver of such privileges.
95 GAMMA INSULATORS CORP. - TERMS & CONDITIONS OF SALE 9. PRICES. Prices are subject to change without notice. Orders based on published prices and accepted for scheduled shipment will be invoiced at Seller s applicable price in effect on the scheduled date of shipment, unless otherwise specifically noted on Seller s order acknowledgement. All prices will be in accordance with applicable government regulations. Orders specifying palletizing or special packaging will involve special charges. 10. DELAYS. All orders are accepted subject to Seller s ability to make delivery at the time and in the quantities specified, and Seller shall not be liable for damages for failure to make partial or complete shipment or for any delay in making shipments. Purchaser shall be liable for any added expenses incurred by Seller because of Purchaser s delay in furnishing requested information to Seller, delay resulting from order changes by Purchaser, or delay in unloading shipments at delivery point. 11. SHIPMENT. Seller will select method of shipment and routing when transportation charges are for account of Seller. When shipping instructions are specified by the Purchaser, all costs in excess of the most economical method of transportation will be for the account of the Purchaser. The foregoing includes, but is not limited to, carrier s charges for notification prior to delivery, demurrage, delay in unloading, diversion, or reconsignment. If Purchaser needs a flatbed, the cost difference between regular truck and flatbed will be charged to the Purchaser, documentation of the difference will be available upon request. 12. FREIGHT ALLOWANCE. Freight terms are based on regular, enclosed truck to single destination, unless otherwise stated. If flatbed truck is required, additional charges will apply if order is freight allowed. Same applies for shipments during weekends, nights, expedite and/or air shipments. Seller s freight allowance is $7, or more per order shipment release to one destination for eastern states (1), $10, for western states (2), and $15, for shipments destined to Canada unless otherwise negotiated. For orders to Alaska and Hawaii that meet freight allowance requirements freight will be paid to the West Coast Port of Exit. The above policy applies to standard dry van ground transit only. The freight allowance terms are FOB Origin, Freight Prepaid. In the event the freight thresholds are not met, the terms will either be FOB Origin, Freight Prepaid and Billed or FOB Origin, Freight Collect. (1). Eastern States: AL, AR, CT, DE, FL, GA, IL, IN, IA, KY, LA, ME, MD, MA, MI, MN, MS, MO, NH, NJ, NY, NC, OH, PA, RI, SC, TN, VT, VA, WV, WI. (2). Western States: AK, AZ, CA, CO, HI, ID, KS, MT, NE, NM, NV, ND, OK, OR, SD, TX, UT, WA, WY. 14. IN TRANSIT CLAIMS. Claims for damage or shortage in transit must be made against the carrier by the owner of the shipment according to the FOB terms of the Contract. Purchaser has the responsibility to inspect shipments before or during unloading to identify any such damage or shortage and see that appropriate notation is made on the delivery tickets or an inspection report furnished by the local agent of the carrier in order to support a claim. 15. CLAIMS. Notice of claims against Seller hereunder for any reason, must be made to Seller in writing within 30 calendar days after discovery and within any applicable warranty period. Failure to give such notice to Seller shall constitute a waiver by Purchaser of any right later to assert such claim. Products must be inspected by Purchaser upon receipt and notice of defects or damage must be given to Seller within 24 hours of receipt of product. 16. RETURNS. All requests for returned goods must first be approved in writing, by the appropriate Product Line Manager. After written approval, returned goods shall be accepted for credit only if in saleable condition and only with evidence of Seller s prior written consent and proof of purchase within one year of request date. Product must be in original packaging and be in standard pack quantities. Special items of other than normal and standard design regularly sold by Seller cannot be returned. Seller will assess a minimum 25% restocking charge, if applicable. Delivery costs to and from the Purchaser that were paid by Seller will be deducted along with all loading and unloading costs and any costs of repair. 17. PATENTS. Seller agrees to defend, and to protect Purchaser against loss or damage usually arising out of any legal action for patent infringement in connection with the manufacture of its products sold to Purchaser, provided Seller is notified within 30 calendar days of any such action with complete information and is given an opportunity to defend. Seller s obligation hereunder shall be subject to the following: That Purchaser has not modified the product and is utilizing it for its intended purpose. In no event shall Seller be liable for any consequential or incidental damages.
96 GAMMA INSULATORS CORP. - TERMS & CONDITIONS OF SALE 18. WARRANTY; LIMITATION OF LIABILITY. Seller warrants title to each individual product sold under the Contract and further warrants for a period of one (l) year after shipment, but only to the extent and limit of the purchase price paid for such individual product, that such product conforms to the specifications set forth in the Contract and is free from defects in material and workmanship under normal service and use for which it was designed. Seller s sole obligation and Purchaser s exclusive remedy under this warranty shall be limited to one of the following, as selected by Seller: delivering to Purchaser a replacement for any product part thereof determined by Seller to be defective; repairing such product or part; or refunding the purchase price (or an equitable portion thereof) paid for such product or part by Purchaser. SELLER MAKES NO WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR MERCHANTABILITY, AND NO OTHER WARRANTY, WHETHER EXPRESS OR ARISING BY OPERATION OF LAW, COURSE OF DEALING, USAGE OF TRADE OR OTHERWISE IMPLIED SHALL EXIST IN CONNECTION WITH SELLER S PRODUCTS OR ANY SALE OR USE THEREOF. Purchaser must notify Seller within 30 calendar days of discovery and within the warranty period of any claim under this warranty. Seller s warranty extends only to the first purchaser of a product from Seller or Seller s authorized distributor. All goods not manufactured by Seller are warranted only to the extent of the warranties of the original manufacturer. Seller disclaims, and shall not be responsible for, any liability arising from tort, including strict liability, and Seller further disclaims, and shall not be responsible for, any liability (whether arising under this or any other provision of the Contract or otherwise) for any costs (including costs of removal and replacement), liabilities, lost profits, loss of good will or any other general, direct, special, incidental or consequential damages incurred by Purchaser in connection with the Contract or any product purchased thereunder, in all cases irrespective of whether Seller was advised of the possibility of such liability. 19. INDEMNIFICATION. Purchaser agrees to indemnify, defend and hold Seller harmless from any and all demands, claims, actions or judgments of a third party against Seller, directly or indirectly, relating to injury and/or death of any and all persons and for loss of and/or damage to property arising out of Purchaser s sale, re-sale and/or misuse of products and/or Purchaser s negligence or willful misconduct. This indemnification obligation shall apply even in the event of the fault, negligence or strict liability of Seller. 20. GOVERNMENTAL REGULATIONS. Seller warrants that no code, law, regulation, or ordinance of the United States, a state or any other governmental authority or agency or any applicable Executive Order has been violated in the manufacture or sale of the items covered by the Contract and warrants that the equipment, supplies and/or articles covered thereby conform with all such requirements. 21. LAW. The Contract shall be governed by and shall be construed by the law of the State of New York, and any disputes arising hereunder will be heard by a court of competent jurisdiction in New York.
produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.
www.ppcinsulators.com The very Best. The very Best. That s what we deliver. ong od Insulators Only a company that develops, produces and delivers products worldwide can provide the optimal solution for
Transmission Silicone Insulators Line Post 69 kv to 161 kv
K-LINE INSULATORS LIMITED Catalogue T-LP Transmission Silicone Insulators Line Post 69 kv to 161 kv ISO9001 SAI GLOBAL FILE No. 000117 Transmission Silicone Insulators Line Post Today transmission lines
Composite Insulators Suspensions Line Posts Brace Posts Station Posts
Composite Insulators Suspensions Line Posts Brace Posts Station Posts Quality, reliability and consistency for over four decades As an alternative and complement to our range of proven ceramic insulators,
The very Best. ANSI Post Insulators 2016
The very Best. ANSI Post Insulators 2016 Introduction ANSI Post Insulators High Tech TR Post Never comprom Better Design enables higher performances with less weight Under normal service conditions, the
TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR
TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR 1.1.0 SCOPE : This specification covers design, manufacture, testing at manufacture s works before
Veri*Lite Deadend & Suspension Insulators for 15-69kV Applications
Veri*Lite Deadend & Suspension Insulators for -69kV Applications Section 22-1 22 Warranty - Material Hubbell Power Systems, Inc. warrants all products sold by it to be merchantable (as such term is defined
25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp
Page 1 2015 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 15 kv or 25 kv Separable Insulated Connector (elbow) Equipment Connection Power Cable Power Cable Grounded Metal
Hi*Lite XL Transmission Insulators
Hi*Lite XL Transmission Insulators Section 261 26 A NOTE: Because Hubbell has a policy of continuous product improvement, we reserve the right to change design and specifications without notice. Copyright
Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)
August, 2009 Vertical Break Parallel (VBP) / Vertical Break Slant (VBS) Type VBPA (Aluminum) / Type VBPC (Copper) Type VBSA (Aluminum) / Type VBSC (Copper) PASCOR Air Break Switch Technology PASCOR offers
Design Test Report Veri*Lite Suspension Insulators Catalog Numbers: 405003, 405004, 405005, 405006
Design Test Report Veri*Lite Suspension s Catalog Numbers: 0003, 000, 000, 000 This design test report records the results of laboratory tests made on the Ohio Brass Veri*Lite Suspension s. Test performed
RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo
Connectors, Clamps, Compensating Devices, Insulators and Safety Equipment for Overhead Catenary Lines RAILWAY CATENARY SYSTEMS Components and Systems for the Electrification of Railway Lines. Welcome to
Medium voltage insulator
Medium voltage insulator Line post insulators type R-ET Commercial designation LPI 24 N ET 1) LPI 24 L ET/5 1)2) LPI 24 L ET/6 1)2) LPI 38 L ET 1) esignation acc. to IEC 720 R 12,5 ET 125 N R 12,5 ET 125
Transformer Bushings for GIS
Transformer Bushings for GIS Oil to SF6 Connections GARIP RTKG 725-55 kv SQS certified ISO 91 / ISO 141 Bushings RIP - Technology for SF6 / Oil - Bushings In modern metal enclosed switchgear SF6 -gas is
Veri*Lite Deadend, Suspension & Line Post Insulators for 15-69kV Applications
Veri*Lite Deadend, Suspension & Line Post Insulators for 15-69kV Applications Section 22-22 Warranty - Material Hubbell Power Systems, Inc. warrants all products sold by it to be merchantable (as such
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
1ZSC000563-AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide
1ZSC000563-AAC en, Rev. 7 Resin impregnated paper bushing, oil to air, type GSB Technical guide Original instruction The information provided in this document is intended to be general and does not cover
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated.
CAST IN PLACE DETECTABLE/TACTILE WARNING SURFACE TILE PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Special Conditions and Division 1 Specifications
HV glass suspension insulator U70BS and U70BL type Ball and socket type Standard profile
U70BS and U70BL type IEC 60305 U70BS U70BL GOST 27661 ПС70Е ПС70Е Minimum mechanical failing load kn 70 70 Minimum mechanical residual strength kn 56 56 Diameter of the insulating part, D mm 255 255 Nominal
1ZSE 2750-105 en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide
1ZSE 2750-105 en, Rev. 8 Transformer bushings, type GOE and GOE(2) Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible
Pole Guying More Complicated Than Meets the Eye. NRECA TechAdvantage 2014 Presented by Jason Settle, P.E. jason.settle@gdsassociates.
Pole Guying More Complicated Than Meets the Eye NRECA TechAdvantage 2014 Presented by Jason Settle, P.E. [email protected] Pole Guying Strength of components NESC vs. RUS Guy Factor Grounding
AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle
Scope This specification stipulates the minimum requirements for mechanically linked three-phase electronic sectionalizers, for use on outdoor medium voltage overhead lines of 15, 27, and 38 kv. Electronic
CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.
CAST IRON THE BASICS 1. DO NOT LIFT ON YOUR OWN. 2. ONLY LIFT THE RADIATOR VERTICALLY. 3. DO NOT LIFT MORE THAN 8/10 SECTIONS AT ANY ONE TIME. 4. POSITION THE RADIATOR BEFORE FINAL ASSEMBLY. 5. THIS PRODUCT
MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003
MiCAFIL 1 RIP Technology Z. Zic 09/2003 )XQFWLRQRI+LJK9ROWDJH%XVKLQJ Uncontrolled (natural) electrical field Capacity-controlled electrical field %XVKLQJV0DLQ,QVXODWLRQ6\VWHPV 7\SH 0DLQ,QVXODWLRQ +RXVLQJFRYHU
Design Test Report Report No. EU1531-H ANSI C29.18 PROTOTYPE/ CEA LWIWG 02 DESIGN TEST REPORT Silicone Rubber 69 kv Veri*Lite Line Post 80S069
Design Test Report Report No. EU1531-H ANSI C29.18 PROTOTYPE/ CEA LWIWG 02 DESIGN TEST REPORT Silicone Rubber 69 kv Veri*Lite Line Post 80S069 This test report records the results of laboratory tests made
SF 6 Gas Insulated Switchgear Type SDF for 170 kv
Three Phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDF for 170 kv 06B1-E-0001 With Trustworthy Technology, Structure Fuji Electric as a manufacturer of comprehensive substation equipment
Veri*Lite Silicone Rubber Line Post Insulators for 15-69kV Applications
Veri*Lite Silicone Rubber Line Post Insulators for 15-69kV Applications Section 2-1 2 Warranty - Material Hubbell Power Systems, Inc. warrants all products sold by it to be merchantable (as such term is
James M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
Cellular Wireless Antennas
Cellular Wireless Antennas A Technical Brief GarrettCom Inc., November 2010 Overview The Cellular Wireless Antenna Technical brief is provided to assist with the design and deployment of the DX940 Cellular
SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS
SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS PART 1: GENERAL 1.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of AW facilities. Closely coordinate construction work
Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW
Complete One Stop Solution for OPGW Cable and Fittings for OPGW 53, Justice Chandra Madhav Road, Kolkata - 700020. India. Phone: 91-33-24748575 / 7565 Fax: 91-33-2476-1955 Email: [email protected] Website:
Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...
Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information
WIRE AND CABLE ENGINEERING GUIDE
DC Hi Pot Testing Excerpt from PRYSMIAN S WIRE AND CABLE ENGINEERING GUIDE (FOR INFORMATIONAL PURPOSES ONLY) Page 1 of 6 DC HIGH POTENTIAL TESTING DC Hi-Pot testing can be applied as a withstand test (a
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
CAUTION. 4. Cable Connections DANGER WARNING CAUTION. 3. Bushing Components
Instruction Manual for POC Bushings 1. Scope This instruction contains general procedures to be followed during receiving, installation, storage and maintenance of all PCORE POC bushings. This instruction
SECTION 15105 DUCTILE IRON PIPE AND FITTINGS
SECTION 15105 DUCTILE IRON PIPE AND FITTINGS PART 1 GENERAL.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of Owner facilities. Closely coordinate construction work and connections
Transmission Foundations. helical piles and guy anchors for transmission structures. www.hubbellpowersystems.com
Transmission Foundations helical piles and guy anchors for transmission structures www.hubbellpowersystems.com Grid locked on your transmission job? Instant Foundation helical piles go places concrete
GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables
Engineering Department SEPTEMBER, 2007 GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables General Requirements This section applies to all public and private utilities,
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
PUSH-PULL CABLES CONTROL SYSTEMS
ISO 9001 CERTIFIED PUSH-PULL CABLES CONTROL SYSTEMS WESCON PRODUCTS COMPANY A subsidiary of LATSHAW ENTERPRISES, INC. WESCON'S PUSH-PULL CONTROL SYSTEMS Push-Pull Cable Ends Wescon Push-Pull Cable Assemblies
SMA Interface Mating Dimensions (Per MIL-STD-348)
SMA Series SMA 6 SMA Interface Mating Dimensions (Per MIL-STD-348) SMA Interface Dimensions MALE Inches/Millimeters 3 Minimum Nominal Maximum LTR in. mm in. mm in. mm A.250 6.35.263 6.68.. B.1790 4.55.1808
Installation Instructions Hustler 6-BTV Trap Vertical
Installation Instructions Hustler 6-BTV Trap Vertical ASSEMBLY 1. Check the package contents against the parts list on page 2. 2. WARNING. Installation of this product near power lines is dangerous. For
CLAMPS CONNECTORS & EQUIPOTENTIAL RING
CLAMPS CONNECTORS & EQUIPOTENTIAL RING March 2015 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata
Lightning Arresters P30027 18 KVA P30038 10 KVA. Description & Installation
Lightning Arresters P30027 18 KVA P30038 10 KVA Description & Installation Printed in USA 09/11 TO330 Rev. B Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT OVERVIEW 2 2.1 Intended Uses 2 2.2 Lightning
An Overview of Lapp Insulator High Voltage Bushing Design
An Overview of Lapp Insulator High Voltage Bushing Design W.A. Young Lapp Insulator Company LeRoy, NY 14482 USA INTRODUCTION High voltage bushings are devices designed to transmit electric energy through
Puddle Flange. FRANK Puddle Flange
Puddle Flange FRANK Puddle Flange The problem Problems keep on occurring when connecting pipes during construction work. Pipes laid in the ground must be introduced into concrete walls or shafts. In many
American National Standard. For Insulators. Wet Process Porcelain and Toughened Glass Suspension Type ANSI/NEMA C29.2-2012
ANSI/NEMA C29.2-2012 American National Standard For Insulators Wet Process Porcelain and Toughened Glass Suspension Type Secretariat: National Electrical Manufacturers Association Approved: October 2012
PC-Concrete Injectable Concrete Anchoring and Repair System
PC-Concrete Injectable Concrete Anchoring and Repair System DESCRIPTION: PC-Concrete is a two component (1:1 ratio), 100% solids, high modulus, structural epoxy paste. PC-Concrete is a solvent free, no
OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd
OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd ACTOM OUTDOOR DISCONNECTORS Single Side Break (SSB) Disconnector 22-132 kv, 800-1 A, 25 ka - 3s Typical bearing assembly. Voltage range 11 kv to 132
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
Implosive Connectors. for overhead transmission lines
Implosive Connectors Implosive Connectors for overhead transmission lines VP metall is situated in Raufoss Industrial Park, where you find the leading know-how in metallurgy and machining technology in
C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S
C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family
When power interruptions happen.
When power interruptions happen. We know it s never a good time to have your power go out, so we work all year pruning trees and investing in our system to cut down on problems before they start. Outage
Modular Systems wind portfolio overview Power Collection and Grid Connection products
Modular Systems wind portfolio overview Power Collection and Grid Connection products Slide 1 Modular Systems wind portfolio Wind power - definition A wind turbine is a device that converts kinetic energy
V.A PJM Design and Application of Overhead Transmission Lines 69kV and Above
V.A PJM Design and Application of Overhead Transmission Lines 69kV and Above These design criteria have been established to assure acceptable reliability of the bulk transmission system facilities. These
Transformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
SECTION 15140 - PIPE HANGERS AND SUPPORTS
Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the
Awning Instructions. Standard Manual 1.5m to 4.5m
Awning Instructions Standard Manual 1.5m to 4.5m English Standard Manual Instructions Contents Warning 1.5m 3.0m Awnings 4 x Expansion bolts (2 per bracket)** 2 x brackets 1 x Awning 1 x Winder handle
Horizontal Jet Pumps 1/3-1-1/2 HP
Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The
Fixed Access Ladders. Table of Contents. 1. Legislative Requirements
Fixed Access Ladders Engineering Data Sheet 2-04 Revised: January 1997 Table of Contents 1. Legislative Requirements 2. General 3. Rungs 4. Side Rails 5. Safety Cages 6. Attachment & Anchoring 7. Platforms
Dock Hardware & Accessory Products Catalog
Dock Hardware & Accessory Products Catalog Product Page # Product Page # Angle Brackets/Clips 8 Back Up Plate 5 Backing Plate/Hurricane Stop 10 Carriage Bolt Sets 4 Chain Retainer 10 Connector Pin Set
WiMo Antennen und Elektronik GmbH Am Gäxwald 14, D-76863 Herxheim Tel. (07276) 96680 FAX 9668-11
The I-PRO Traveller part no. 11440 Thank you for your purchase, please take your time to digest some of the important building tips and the essential matching/adjustment techniques. You will need 8m of
Complete System Shelter
Complete System Shelter For Weather Console Installations The weather resistant Complete System Shelter (CSS) provides protection from the elements for system components such as the Vantage Pro2 and Vantage
Ordering Information. Specifications. Electrode Holder PS-@S(R)/-31. Electrode Holders. Accessories (Order Separately)
Holder PS-@S(R)/-31 Separate Holders for Water Supply and Drainage Control in Buildings. Small, Lightweight Holders for Use as Built-in Components. The PS-@S(R) are separate Holders that allow the s to
INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS
INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS GENERAL DESCRIPTION:
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER
CABLE ACCESSORIES 110-220 kv
CABLE ACCESSORIES 110-220 kv Termination 110 kv Technical description Termination MKB 126 / 145 with composite type insulator uses for cable line joints with other elements of power-supply systems. Termination
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE PART 1: GENERAL 1.01 SECTION INCLUDES PVC pressure pipe and fabricated fittings in nominal sizes 4-inches through 12-inches with cast iron pipe equivalent
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona
for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety
Low Voltage Transformers Sealed, General Purpose, Dry Type
Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................
Screw Thread Design. Rev. 3-4-09
Screw Thread Design Screw Thread Fundamentals A screw thread is defined as a ridge of uniform section in the form of a helix on either the external or internal surface of a cylinder. Internal threads refer
CLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
Chapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS.
Austin City Code - Volume II TITLE 25 LAND DEVELOPMENT\CHAPTER 25-12 TECHNICAL CODES\ARTICLE 1: UNIFORM BUILDING CODE\25-12-3 LOCAL AMENDMENTS TO THE BUILDING CODE Chapter 36 - STRAW BALE CONSTRUCTION
Scepter PVC Molded Junction Boxes
Scepter PVC Molded Junction Boxes ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" We build tough products for tough environments Standing Still is Not an Option. We re proud to introduce the NEW
SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION
SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION PART 1 GENERAL.01 SECTION INCLUDES Furnishing and installing 4 inch through 16 inch high density
Electrical Safety Products
Electrical Safety Products Trelleborg Electrical Safety Products A safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount. Trelleborg
MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS
MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS Meher Capacitors offers reliable and innovative products and solutions in the fields of Reactive Power Compensation, Power Quality and Energy
K2 STONE NATURAL VENEER
INTRODUCTION WHAT IS K2 NATURAL THINSTONE VENEER? Natural K2 Stone veneer is real stone, cut 1 inch thick, making it light enough to be installed as a veneer. Sometimes referred to as thin veneer, thin
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+
Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+ The wall sleeve The wall sleeve a largely unnoticed but very important sealing part. Wall sleeves
Mueller. Pipe Repair Products. A complete selection for all types of gas lines... all from a single source. GAS PRODUCTS DIVISION
Mueller Pipe Repair Products A complete selection for all types of gas lines... all from a single source. GAS PRODUCTS DIVISION MUELLER STAINLESS STEEL REPAIR CLAMPS Mueller offers a full line of stainless
Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.
Mueller Pipe Repair Products Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source. SERVICE SADDLES Mueller service saddles, available in bronze,
Capacitor Voltage Transformer. Answers for energy.
Capacitor Voltage Transformer Answers for energy. Capacitor Voltage Transformer Siemens Capacitor Voltage Transformers are based on technology from Trench, a recognized world leader in the design and manufacture
Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia
Exel Composites Cable Support Systems offer engineers a structural product for solving many design and plant engineering problems, enabling long term reliable support of expensive and often critical cables.
Wastewater Capital Projects Management Standard Construction Specification
CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,
ABLOY DOOR AUTOMATICS Easy access for all types of swing doors
ABLOY DOOR AUTOMATICS Easy access for all types of swing doors Automatic door operators bring additional convenience in situations where the doors opening manually would be inconvenient or laborious. Recommended
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials
60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality
IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION Generated: Sergiy Papyshev Engineering Approved: Don Prysi Manufacturing Approved: Merzuk Ramic Quality Approved: Steven Barnett Administrative DATE DATE DATE
Byonics Micro Trak 1000 High Altitude Balloon Tracker
Byonics Micro Trak 1000 High Altitude Balloon Tracker The Micro Trak 1000 (MT 1000) is a high altitude balloon (HAB) tracker. It is usually sold as a combination to provide a simple, turn key tracking
F-Series Camera Mounting Accessories
F-Series Camera Mounting Accessories Document Number: 427-0462-00-12 Version: 100 Issue Date: September 2010 2010. All rights reserved worldwide. FLIR Commercial Systems, Inc. 70 Castilian Drive Goleta,
SECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:
Two most common lock nut groups: 1. PREVAILING TORQUE a design feature of the lock nut produces friction between threads of mated components thereby increasing the force needed to tighten as well as loosen
Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.
Power Voltage Transformers for Air Insulated Substations THE PROVEN POWER. Introduction Trench Power Voltage Transformers (Power VTs) combine the attributes of an inductive voltage transformer with the
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Cable Trays Technical Instructions & Specifications
Cable Trays Technical Instructions & Specifications Products Catalogue Objective and Structure The company s main objective is the supply of quality products, with respect to: practical design increased
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
DISCONNECTORS AND LOAD SWITCHES for railways
DISCONNECTORS AND LOAD SWITCHES for railways GRID Disconnectors and load switches for railways Alstom Grid delivers transmission solutions worldwide to utility and large industrial customers seeking smarter,
LAYING BLOCK AND BRICK
LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct