1 Anchor table ejotherm anchors with European Technical Approval (ETA) Fasteners for insulation boards Rail systems ejotherm ejotherm ejotherm ejotherm ejotherm ejotherm STR U STR H NT U NTK U SDK U NK U page 16 page 17 page 20 page 21 page 24 page 25 Normal weight concrete C 12/15 acc. to EN Normal weight concrete C 16/20 - C 50/60 EN Clay bricks (Mz) acc. to DIN 105 Solid lime sandstone (KS) DIN EN 106 Solid masonry of lightweight concrete (V) DIN Vertically perforated clay bricks (Hlz) acc. to DIN 105 Sand-lime perforated bricks (KSL) DIN EN 106 Lightweight concrete hollow blocks (HbL) DIN Lightweight aggregate concrete (LAC) Vertical coring reference bricks (Hlz) ÖNORM B 6124 Autoclaved aerated concrete P2 - P7 Wooden substrates and metal sheets (without ETA) Fastening solutions for special applications with German DIBt approval Clinker systems Specialty solutions EJOT EJOT EJOT EJOT EJOT SDF S plus 8UB SDP S plus 8 SDM T plus 8/60U VSD WSS/KERI page 28 page 29 page 30 page 32 page 33 Normal weight concrete Clay bricks Solid lime sandstone Vertically perforated clay bricks Solid masonry or solid blocks of lightweight concrete Sand-lime perforated bricks Lightweight concrete hollow blocks Weather panels of three layer facade envelope (concrete) Lightweight aggregate concrete Autoclaved aerated concrete acc. to DIN Autoclaved aerated concrete acc. to TGL Application ruled in the approval Proof of qualification through tests on the building no approval
2 Imprint Publisher: EJOT Baubefestigungen GmbH Bad Laasphe Germany Layout and execution: conception Werbung & Marketing GmbH, Siegen EJOT Baubefestigungen GmbH Photos: Title and Underground garage, Niels Otto Bricklayer, Birgid Allig/zefa/Corbis Freiherr-vom-Stein-Gymnasium, Münster, Christian Richters Fotografie Schlossarkaden Braunschweig, ECE Products, Theissen Fotodesign Print: Schlabach GmbH & Co. KG, D Erndtebrück Legal notes: Our latest sales terms and delivery conditions apply. EJOT products are constantly enhanced. They are subject to technical changes, assortment and price changes. During planning and use of our products please comply with accepted engineering rules, planning laws as well as relevant safety regulations. The national technical approvals granted to our products can be downloaded on the internet at by EJOT Baubefestigungen GmbH EJOT is a registered trademark of EJOT GmbH & Co. KG. ejotherm is a registered trademark of EJOT Baubefestigungen GmbH. TORX is a registered trademark of Camcar, Div. of Textron, Rockford, IL.
3 Content 4 Your strong partner 6 ETICS experience 12 References 13 The ejotherm generation 14 The EJOT STR principle 15 ejotherm plate anchors 16 ejotherm STR U Cap anchor for concrete and masonry 17 ejotherm STR H Cap anchor for wood and metal sheets 18 ejotherm STR accessories 20 ejotherm NT U Universal hammer-in anchor 21 ejotherm NTK U Telescope anchor 22 EJOT additional plates 23 ejotherm anchors for rail fastenings 24 ejotherm SDK U Screw-in anchor for rails 25 ejotherm NK U Hammer-in anchor for rails 26 Accessories for rail fastenings 27 EJOT anchors for clinker systems 28 EJOT SDF S plus 8UB Clinker system anchor for concrete and masonry 29 EJOT SDP S plus 8 Clinker system anchor for gas concrete 30 Solutions for special applications 30 EJOT SDM T plus 8/60U Specialist for problematic substrates 31 EJOT SDF K plus 8U Specialist for rail systems on problematic substrates 32 EJOT VSD Renovation anchor for prewall shells 33 EJOT WSS and Keri Renovation rods for weather shells 34 EJOT special drill for optimum loads in peforated bricks 34 EJOT spiral anchor for fastening of light attachments on ETICS facades 35 Fasteners for ceiling insulation 36 EJOT DDS and DDT Ceiling insulation screw with additional plate 37 EJOT DDA Ceiling insulation anchor 38 EJOT DMH and DMT Metal insulation support with additional plate 39 EJOT anchor basics 3
4 Your strong partner EJOT Building Fasteners: Over 30 years of special knowledge around the building envelope b a Industrial lightweight construction (ILB) High-quality fastener products for fixing profiled sheets and sandwich panels on industrial steel frame construction External Thermal Insulation Composite Systems (WDVS) Special anchors for fixing insulation on external wall systems a plate anchors for direct fastening of insulation boards on the facade b anchors for fastening of base and profile rails c specialty solutions for rebuilding stability d fastening solutions for ceiling insulations e specialty solutions and accessories Rear ventilated facades (VHF) Fasteners and anchors for fixing brackets to substrate, frame to brackets, insulation to substrate and facade fascias on rear ventilated systems c a 4 5 Flat roofing (FLD) Fasteners, stress plates and installation tools for the efficient attachment of insulation and waterproof membrane to deck Industrial Window and Facades Technique (IFF) Application specific fasteners for UPVC window and door manufacturing and aluminium/glass curtain wall systems 4
5 Your strong partner EJOT Your strong partner for fastening solutions in the building industry l Expertise and experience With over 30 years of experience and development know-how Made in Germany, we understand the requirements of a fastener and its application on building envelopes very precisely. Our knowledge is the base and source of our products and subsequent solutions which offer our customers real benefits. l Quality and easy installation The quality of our products surpasses planning laws and legal requirements. Our highest aim is to ensure quick and easy assembly. l Customer-friendly service We make a point of building trusting and friendly relationships with our customers. Our personal advisers offer 24-hour customer service. If required our employees deliver technical back-up on the building site. In addition we provide our knowhow through training seminars. l There for you worldwide Our Europe-wide sales and service network with over 25 subsidiaries as well as a worldwide project support team is pleased to help our customers at any time. 5
6 ETICS competency Your service Our quality: EJOT philosophy sets standards Are you absolutely sure what is behind the old rendering? ETICS are often used in renovation. The major part of the structural fabric is of bad quality or combined masonry was used. The bearing capacity of the old render is reduced through environmental stress. The ejotherm anchor generation provides safety. Especially the ejotherm STR U can be used in any substrate. As the first 8 mm ETICS anchor, it obtained a European Technical Approval for all building material categories. Despite shortest anchorage depths, it reaches the highest characteristic loads. With EJOT quality your service promise will not hang by a thread
7 ETICS competency I cannot afford a construction site to stagnate due to installation problems. And even worse are customer complaints. Today, everything has to be fast and smooth but without reduction of quality and security. EJOT anchors are great to work with. Especially the STR principle is simply ingenious. 100% setting control and homogeneous insulation surfaces thus I can still relax after many years. 7
8 ETICS competency Your system Our know-how: over 30 years of ETICS anchors by EJOT Through our close contact to practitioners and developers, we are able to develop ideal fastening solutions for today s and tomorrow s facade insulation systems. Make use of this head start for your system! And experience how decades of know-how reveal in easy and quick installation. Based on this practical experience, in special cases our experts work out individual solutions for you even right on the building site. Some examples of our service: l personal consultants - even on the building site l competent consulting via phone or l fast and reliable delivery service l anchor pull-out tests on site l trainings in fastening technology l support with bidding processes Your benefits: l custom-designed solutions you can rely on l our decades of know-how l planning security
9 ETICS competency As consultant of a system owner, I know the daily perfidies and annoyances that make life hard for users and cost them valuable time. With EJOT anchors, the right choice is easy. And I can rely on that they work even when the conditions at the object are not ideal.! EJOT anchors for ETICS are important components of high-grade facade systems. Like all other system components they are exclusively sold to system owners. 9
10 ETICS competency Your advantage Our programme: anchor choice made easy Which anchor do I need for which substrate? What do I do when faced with mixed masonry? Our ejotherm family with European Technical Approval (ETA) simplifies your choice. Powerful anchors provide for secure fastening in all substrates and with all kinds of insulation materials. Your benefits: l clear product range for all substrates l solutions for all insulation materials l easy anchor choice l reduced stock volume Moreover you have a special programme with cost-efficient special solutions at your hand. Typical applications are: l rebuilding the stability of damaged ETICS l solutions for renovating the renovation l re-establishing the stability of weather shells and prewall shells Use category A Use category B Use category C Use category D Use category E ejotherm STR U competitive product A competitive product B competitive product C Normal weight concrete Solid masonry Hollow or perforated masonry Lightweight aggregate concrete Autoclaved aerated concrete 10
11 ETICS competency To me as a planer, energy savings and the design of a new ETICS facade are most important. Moreover I am responsible that the facade is secure and immaculate even after years this is what the client expects. That is why we advertise ejotherm STR U. If necessary, EJOT experts already consult me during the bidding process even right on the building site. 11
12 References Freiherr-vom-Stein-Gymnasium, Munster EJOT The Quality Connection: international customers rely on EJOT During more than three decades, over 500,000,000 sqm of ETICS facades have been fastened with EJOT anchors without even a single incident! This equals an area of more than 70,000 football pitches. Roughly 150 billion liters of heating oil or 440 million tons of CO 2 have been saved a valuable contribution to the environment. And they get more by the day. More and more international customers and principals rely on sophisticated fastening solutions and the competent advice by EJOT. EJOT quality connects also internationally! Ginger & Fred, Prague Estate Blumlägerfeld, Celle Schloss-Arkaden Braunschweig Music Academy, Stuttgart 12
13 The ejotherm generation Up to 45 mm shorter anchor lengths Short and good quick and economic: performance up, costs down The new ejotherm generation makes it possible. Specially developed expansion zones enable highest characteristic loads with minimum anchorage depths. The result: quick installation and economic total cost. Your benefits: l up to 45 mm shorter anchor lengths *) l valuable safety reserves in doubtful substrates l economic anchor usage l universal expansion zones for maximum use range l universal drill diameter for all substrates (8 mm) *) in comparison with earlier EJOT anchors nominal anchorage depth h nom characteristic load ejotherm STR U ejotherm NT U competitive product A competitive product B cost installation time, anchor length, drill abrasion performance safety, number of anchors/m 2, sensitivity with varying substrate qualities Substrate: Vertically perforated clay bricks (Hlz) Source: specifications of the individual European Technical Approval (ETA) 13
14 The EJOT STR principle Your guarantee Our STR principle For long-lasting beautiful facades With its STR principle, EJOT has developed a unique fastening system. Without any additional work, the anchor plates are installed countersunk and covered with an insulation cap. This creates a homogenous surface and an even rendering, and helps to avoid anchor marks. For all substrates The ejotherm STR U is the first 8 mm ETICS anchor with European approval for all building materials, including gas concrete (use categories A - E). For fastenings on wooden materials we provide ejotherm STR H. Both anchors are installed with the same ejotherm STR tool. Easy installation: Quick drilling thanks to reduced drill depth Put anchor with pre-mounted screw into the hole until the plate bears on the surface Screw with the STR tool: countersinking happens automatically (no milling, no dust) Insert the STR insulation cap ready! For all insulation materials Both ejotherm STR U and ejotherm STR H can be either installed countersunk according to the STR principle or plain with the surface with the STR plug. This way an adaptation to all commonly used types of insulation is possible. Quality and safety in XXL The EJOT STR princple is available for insulation of up to 360 mm the perfect fastening system for zero- and lowenergy houses. 14
15 ejotherm plate anchors ejotherm plate anchors anchor choice made easy When fastening an ETICS, insulation boards are usually attached to the facade with adhesive and then fastened with anchors. The bearing load of the system is carried onto the facade via shearing forces. High-quality plate anchors installed through the insulation guarantee additional contact pressure through their stiff plates. This contact pressure supports the permanent frictional bonding between adhesive and substructure. Through a powerful anchoring in the wall and the contact pressure of the plate, the tension of the insulation releases ( screw clamp effect ). ejotherm plate anchors with European Technical Approval offer certified safety even under high wind loads. Through their plates and the expansion element, they redirect the tensile load into the bearing substructure. The plate anchors of the ejotherm generation make things easy for you: Easy anchor choice for safe anchoring in any building material. Together with a minimum anchor depth and maximum performance. Performance up, total cost down! For long-lasting, energy-saving facades. 15
16 ejotherm STR U Cap anchor for concrete and masonry l approved for all categories of building materials l the EJOT STR principle with STR cap for homogeneous surfaces and even rendering - quick and easy without milling dust l also installable plain with the surface with STR plug l shortest anchorage depths, highest loads for maximum safety and economic anchor usage l permanent contact pressure l optimised thermal bridges l premounted screw for quick installation l 100% setting control: the countersunk installation of the plate signalises safe anchorage Technical data Installation Anchor diameter 8 mm Plate diameter 60 mm Drill hole depth, countersunk installation h 1 >_ 50 mm (90 mm) Drill hole depth, plain with the surface h 2 >_ 35 mm (75 mm) Anchorage depth h ef >_ 25 mm (65 mm) Use categories acc. to ETA A, B, C, D, E European Technical Approval ETA-04/0023 Values in parentheses: anchoring in gas concrete (use category E) Characteristic loads Normal weight concrete C 12/15 acc. to EN kn Normal weight concrete C 16/20 - C 50/60 acc. EN kn Clay bricks (Mz) acc. to DIN kn Solid lime sandstone (KS) acc. to DIN EN kn Solid masonry of lightweight concrete (V) acc. DIN kn Vertically perforated clay bricks (Hlz) acc. to DIN kn Vertical coring reference bricks (Hlz) acc. ÖNORM B kn Sand-lime perforated bricks (KSL) acc. to DIN EN kn Lightweight concrete hollow blocks (HbL) acc. DIN kn Lightweight aggregate concrete (LAC) 0.9 kn Autoclaved aerated concrete P2 - P kn Regarding design loads the national safety factors are to be incorporated (e.g. Germany: 3). Please observe the approval. Countersunk installation acc. STR principle with STR cap Installation plain with the surface with STR plug Product range Use category Use category Product name Use category Use category Product name A D E and A D E and Insulation (mm) Insulation (mm) length (mm) Insulation (mm) Insulation (mm) length (mm) New build. ¹) Renovation ²) New build. ¹) Renovation ²) New build. ¹) Renovation ²) New build. ¹) Renovation ²) ) ejotherm STR U ejotherm STR U ) ejotherm STR U ejotherm STR U ) ejotherm STR U ejotherm STR U ejotherm STR U ejotherm STR U ejotherm STR U ejotherm STR U ejotherm STR U ejotherm STR U ejotherm STR U ejotherm STR U ejotherm STR U 255 Product code: (e.g. ejotherm STR U 115: ). ¹ ) 10 mm adhesive ² ) 3) 10 mm adhesive and 20 mm old render to be installed plain with the surface only Note: Always use in combination with STR cap and STR plug respectively. Packaging: 100 pieces each. 16
17 ejotherm STR H Cap anchor for wood and metal sheets l for wooden substrates as well as metal sheets of up to 0.75 mm l the EJOT STR principle with STR cap for homogenous surfaces and even rendering - quick and easy without milling dust l also installable plain with the surface with STR plug l permanent contact pressure l 100% setting control: the countersunk installation of the plate signalises safe anchorage Installation Technical data Screw diameter Plate diameter Screw-in depth 6 mm 60 mm mm Recommended use loads Wood fibreboards (thickness >_ 17,0 mm) Chipboards (thickness >_ 13,0 mm) Gypsum fibreboards (thickness >_ 12,5 mm) OSB plates (thickness >_ 16,0 mm) Solid wood plates (thickness >_ 27 mm) The recommended use loads are calculated with a safety factor of 3. They may differ according to the object kn 0.25 kn 0.15 kn 0.25 kn 0.25 kn Countersunk installation acc. STR principle with STR cap Installation plain with the surface with STR plug Product range Countersunk Installation plain Product name Product code installation with the surface and Insulation (mm) Insulation (mm) length (mm) ) 40 ejotherm STR H ejotherm STR H ejotherm STR H ejotherm STR H ejotherm STR H ejotherm STR H ejotherm STR H ejotherm STR H Note: Always use in combination with STR cap and STR plug respectively. Further lengths on request. Packaging: 100 pieces each. 17
18 ejotherm STR accessories ejotherm STR cap EPS l specially developed system cap of polystyrene (EPS) l to be used with ejotherm STR U and ejotherm STR H l colours: white or grey ejotherm STR cap MW l specially developed system cap of mineral wool l to be used with ejotherm STR U and ejotherm STR H ejotherm STR plug l sepcial plug of polystyrene (EPS) l to be used with ejotherm STR U when installed plain with the surface (included with ejotherm STR H) Product range Product name Product code Packaging (pieces/box) ejotherm STR cap EPS white ejotherm STR cap EPS grey ejotherm STR cap MW ejotherm STR plug
19 ejotherm STR accessories ejotherm STR tool l specially developed tool for countersunk installation of ejotherm STR U and ejotherm STR H l sturdy construction for long durability l wear parts are exchanged quickly l set comprises: STR-tool, additional cutting metals, angle screw driver, bits for all applications ejotherm STR tool spare kit l to replace wear parts of the STR tool l set comprises: 3 cutting metals, 3 bits for countersunk installation ejotherm STR renovation cutter l for subsequently securing ETICS facades: cost-efficient re-establishment of the structural stability through subsequent anchoring l avoids the de-installation of the old system in many cases l utilisation of the EJOT STR technology: 1. mill the existent plaster layer, 2. install the ejotherm STR U, 3. insert the STR cap to obtain an even plaster base, 4. plaster a new final rendering Product range Product name Product code Packaging (pieces/box) ejotherm STR tool ejotherm STR tool spare kit ejotherm STR renovation cutter
20 ejotherm NT U Universal hammer-in anchor l approved for concrete, solid and perforate masonry l solid steel nail (break-proof) l plastic injection moulding to reduce thermal bridges l installable with additional plate l shortest anchorage depths, minimum drill hole depth l high loads for your security l economic anchor usage l premounted nail for quick installation Technical data Installation Anchor diameter Plate diameter Drilll hole depth h 1 >_ Anchorage depth h ef >_ Use categories acc. to ETA European Technical Approval (ETA) 8 mm 60 mm 35 mm 25 mm A, B, C ETA-05/0009 Characteristic loads Normal weight concrete C 12/15 acc. to EN kn Normal weight concrete C 16/20 - C 50/60 acc. EN kn Clay bricks (Mz) acc. to DIN kn Solid lime sandstone (KS) acc. to DIN EN kn Solid masonry of lightweight concrete (V) acc. DIN kn Vertically perforated clay bricks (Hlz) acc. to DIN kn Sand-lime perforated bricks (KSL) acc. to DIN EN kn Lightweight concrete hollow blocks (HbL) acc. DIN kn Regarding design loads the national safety factors are to be incorporated (e.g. Germany: 3). Please observe the approval. Product range Insulation (mm) Product name Product code New build. ¹) Renovation ²) and length (mm) ejotherm NT U ejotherm NT U ejotherm NT U ejotherm NT U ejotherm NT U ejotherm NT U ejotherm NT U ejotherm NT U ejotherm NT U ejotherm NT U ejotherm NT U ¹ ) 10 mm adhesive ² ) 10 mm adhesive and 20 mm old render Packaging: 100 pieces each. 20
21 ejotherm NTK U Telescope anchor l approved for concrete, solid and perforated masonry l defined move-in of the plate through the EJOT telescope effect: with the last blow, the plate decouples and moves on the sleeve while the expansion zone is safely anchored l safe and smooth installation with built-in setting control through the EJOT telescope effect l optimised thermal bridge l minimised risk of breaking nails due to fibre-reinforced composites l premounted expansion nail for quick installation Installation Technical data EJOT Telescope Effect Put the anchor into the borehole until the plate bears on the insulation, hammer the nail into the sleeve Anchor diameter Plate diameter Drill hole depth h 1 >_ Anchorage depth h ef >_ Use categories acc. to ETA European Technical Approval (ETA) 8 mm 60 mm 50 mm 40 mm A, B, C ETA-07/0026 Characteristic loads With the next blow the plate decouples from the sleeve and moves into the insulation Normal weight concrete C 12/15 acc. to EN kn Normal weight concrete C 16/20 - C 50/60 acc. EN kn Clay bricks (Mz) acc. to DIN kn Solid lime sandstone (KS) acc. to DIN EN kn Vertically peforated clay bricks (Hlz) acc. to DIN kn Sand-lime perforated bricks (KSL) acc. to DIN EN kn Regarding design loads the national safety factors are to be incorporated (e.g. Germany: 3). Please observe the approval. Product range Insulation (mm) Product name Product Code and length (mm) New build. ¹) Renovation ²) 40 ejotherm NTK U ejotherm NTK U ejotherm NTK U ejotherm NTK U ejotherm NTK U ejotherm NTK U ejotherm NTK U ¹ ) 10 mm adhesive ² ) 10 mm adhesive and 20 mm old render Packaging: lengths : 200, otherwise 100 pieces each. ejotherm NTK U length 230 available from mid Please contact your EJOT team. 21
22 EJOT additional plates Additional plates The plate diameter is enlarged through specially matched additional plates. In this way the EJOT plate anchor is perfectly fitted to the demands of different insulation materials. Which additional plates are used in a specific case, depends on the specifications of the ETIC system owner. EJOT VT 90 l plate diameter: 90 mm l high plate solidness for smooth move-in of the plate l smooth installation EJOT SBL 140 plus l plate diameter: 140 mm l specially for mineral wool lamella boards l high plate solidness for smooth installation l high buckling loads thanks to additional plaster bonding Product range Product name Product code Packaging (pieces) EJOT VT EJOT SBL 140 plus When using additional plates the STR principle cannot be applied. When combining our additional plates with ejotherm STR U or ejotherm STR H, the special STR closing plugs have to be mounted. 22
23 ejotherm anchors for rail fastenings ejotherm anchors for rail-fixed ETICS A special kind of External Thermal Insulation Composite Systems is the mechanical fixing of the insulation boards with the help of holding rails. These systems are preferably used on old facades with large tolerances (unevenness of the old render) or significantly damaged old render (lose parts, partially missing old render). Holding rails of plastic or aluminium are directly fastened on the substrate with special collar head anchors. Our spacers EJOT AS balance tolerances and bridge missing parts. Simply clip the chosen thickness onto the anchor between wall and holding rail ready! System-specific insulation boards are put into the profiles of holding rails through incorporated grooves. For additional anchoring of the insulation in the centre of the board, we recommend our cap anchor ejotherm STR U (see page 16). For problematic substrates we offer our special anchor EJOT SDF-K plus 8 U (page 31). 23
24 ejotherm SDK U Screw-in anchor for rails l for installing holding and base rails l approved for all categories of building materials l shortest anchorage depths, minimum drill hole depths l highest loads for maximum safety l economic anchor usage l premounted screw for quick installation l to compensate facade tolerances use spacers EJOT AS Technical data Installation Anchor diameter 8 mm Collar diameter 16 mm Drill hole depth h 1 >_ 35 mm (75 mm) Anchorage depth h ef >_ 25 mm (65 mm) Screw drive TORX T30 Use categories acc. to ETA A, B, C, D, E European Technical Approval (ETA) ETA-04/0023 Values in parentheses: anchoring in gas concrete (use category E) Characteristic loads Normal weight concrete C 12/15 acc. to EN kn Normal weight concrete C 16/20 - C 50/60 acc. EN kn Clay bricks (Mz) acc. to DIN kn Solid lime sandstone (KS) acc. to DIN EN kn Solid masonry of lightweight concrete (V) acc. DIN kn Vertically perforated clay bricks (Hlz) acc. to DIN kn Vertical coring reference bricks (Hlz) acc. ÖNORM B kn Sand-lime perforated bricks (KSL) acc. to DIN EN kn Lightweight concrete hollow blocks (HbL) acc. DIN kn Lightweight aggregate concrete (LAC) 0.9 kn Autoclaved aerated concrete P2 - P kn Regarding design loads the national safety factors are to be incorporated (e.g. Germany: 3). Please observe the approval. To compensate facade tolerances use spacers EJOT AS (p. 26). Product range Max. tolerance Product name Product code compensation (mm) and length (mm) 20 ejotherm SDK U ejotherm SDK U ejotherm SDK U ejotherm SDK U Packaging: 100 pieces each, in box per 1,000 pieces. 24
25 ejotherm NK U Hammer-in anchor for rails l for installing holding and base rails l approved for concrete, solid and perforated masonry l shortest anchorage depths, minimum drill hole depths l high loads for high security l premounted nail for quick installation l to compensate facade tolerances use spacers EJOT AS Installation Technical data Anchor diameter Collar diameter Drill hole depth h 1 >_ Anchorage depth h ef >_ Use categories acc. to ETA European Technical Approval (ETA) 8 mm 16 mm 35 mm 25 mm A, B, C ETA-05/0009 Characteristic loads Normal weight concrete C 12/15 acc. to EN kn Normal weight concrete C 16/20 - C 50/60 acc. EN kn Clay bricks (Mz) acc. to DIN kn Solid lime sandstone (KS) acc. to DIN EN kn Solid masonry of lightweight concrete (V) acc. DIN kn Vertically perforated clay bricks (Hlz) acc. to DIN kn Sand-lime perforated bricks (KSL) acc. to DIN EN kn Lightweight concrete hollow blocks (HbL) acc. DIN kn Regarding design loads the national safety factors are to be incorporated (e.g. Germany: 3). Please observe the approval. To compensate facade tolerances use spacers EJOT AS (p. 26). Product range Max. tolerance Product name Product code compensation (mm) and length (mm) 20 ejotherm NK U ejotherm NK U ejotherm NK U Packaging: 100 pieces each, in box per 1,000 pieces. 25
26 Accessories for rail fastenings EJOT spacers AS l for levelling out facade tolerances: lengths can be combined individually (3, 5, 8, 10, 15 and 30 mm) l simply clip onto the anchor between wall and rail l for anchor diameters 6 mm, 8 mm and 10 mm l sorted by colour EJOT profile connector PV l for connecting profile rails l simply clip onto the rail elements to be connected l facilitates the precise adjustment of base rails l length: 30 mm each EJOT nail anchors ND K 6 x 60 and 8 x 75 l premounted nail anchor to mount base rails l diameters: 6 mm and 8 mm l drill hole depth: >_ 40 mm l anchorage depth: >_ 30 mm EJOT installation set l special composition of frequently used accessories for installing base rails l set comprises: 75 nail anchors ND-K 6 x 60, 10 profile connectors PV, 50 spacers AS 3 Product range Product name Product code Packaging (pieces) EJOT AS (box: 3.000) EJOT AS (box: 2.500) EJOT AS EJOT AS EJOT AS EJOT AS EJOT profile connector PV EJOT ND-K 6 x (box: 1.000) EJOT ND-K 8 x (box: 1.000) EJOT installation set set (box: 10 sets) 26
27 EJOT anchors for clinker systems EJOT anchors for prefabricated ETICS with clinker External Thermal Insulation Composite Systems open a multitude of optical design scopes to significantly improve energy efficiency and outlook at the same time when renovating a facade. Besides different renderings and colourings, ceramic claddings have become increasingly popular. Due to the significantly higher mass per unit area, clinker-built ETICS are generally anchored. ETICS with facing clinker that is already glued on the insulation board usually allow for a purely mechanical fastening with special countersunk anchors directly to the facade. The holes are almost invisible at the joint pattern. If the ceramic cladding is glued on after the anchoring, either completely or in parts, it is recommendable to use ejotherm plate anchors. When using the cap anchor ejotherm STR U with cap, an advantageous decoupling of the facing clinker from the anchor plates is achieved. 27
28 EJOT SDF S plus 8UB Clinker system anchor for concrete and masonry l approved for concrete, solid and perforated masonry l torsion-proof anchor tube l anchor tube with small countersunk head for unobtrusive installation in the joint l universal expansion zone for safe anchoring l high loads l anchor with increased bending moment l premounted screw for quick installation Technical data Installation Anchor diameter Diameter of countersunk head Drill hole depth h 1 >_ Anchorage depth h ef >_ Screw drive German DIBt Approval 8 mm 12 mm 80 mm 70 mm TORX T30 Z Design loads Normal weight concrete >_ C 12/15 acc. to EN Weather shell of concrete >_ B 15 Clay bricks (>_ Mz 12) acc. to DIN 105 Solid lime sandstone (>_ KS 12) acc. to DIN EN 106 Solid masonry of lightweight concrete (>_ V 2) DIN kn 0.25 kn 0.4 kn 0.4 kn 0.2 kn Vertically perforated clay bricks (Hlz) acc. to DIN 105 * Vertical coring reference brick (Hlz) acc. ÖNORM B kn Sand-lime perforated bricks (>_ KSL 6) acc. DIN EN kn Lightweight concrete hollow blocks (>_ HbL 2) DIN kn Lightweight aggregate concrete 0.3 kn * according to approval to be determined through pull-out tests at the building The design loads given are in accordance with the German building code. National safety factors are already incorporated. Please observe the approval. Product range Insulation (mm) Product name Product code and length (mm) zinc-plated steel steel with Deltaseal ¹) stainless steel A4 New build. Renovation ²) 20 EJOT SDF S plus 8UB x EJOT SDF S plus 8UB x EJOT SDF S plus 8UB x EJOT SDF S plus 8UB x EJOT SDF S plus 8UB x EJOT SDF S plus 8UB x EJOT SDF S plus 8UB x ¹ ) organic coating for higher corrosion resistance ² ) 20 mm old render Packaging: 100 pieces each. 28
29 EJOT SDP S plus 8 Clinker system anchor for gas concrete l approved for gas concrete l torsion-proof anchor tube l anchor tube with small countersunk head for unobtrusive installation in the joint l special expansion zone with hooks for form-fit anchoring l high loads l premounted screw for quick installation Installation Technical data Anchor diameter Diameter of countersunk head Drill hole depth h 1 >_ Anchorage depth h ef >_ Screw drive German DIBt Approval 8 mm 12 mm 120 mm 110 mm TORX T30 Z Design loads Autoclaved aerated concrete acc. DIN (2 and 3.3 resp.) 0.2 kn Autoclaved aerated concrete acc. DIN (4 and 4.4 resp.) 0.5 kn Autoclaved aerated concrete acc. TGL (Laußig plant) 0.3 kn Autoclaved aerated concrete acc. TGL (Parchim plant) 0.15 kn The design loads given are in accordance with the German building code. National safety factors are already incorporated. Please observe the approval. Product range Insulation (mm) Product name Product code and length (mm) zinc-plated steel stainless steel New build. Renovation 1) 20 EJOT SDP S plus 8 x EJOT SDP S plus 8 x EJOT SDP S plus 8 x EJOT SDP S plus 8 x ¹ ) 20 mm old render Packaging: 100 pieces each. 29
30 Solutions for special applications EJOT SDM T plus 8/60 U Specialist for problematic substrates l approved for concrete, solid and perforated masonry l universal expansion zone for for problematic substrates and high tolerances l also available for very thick insulation (up to 340 mm) l solid steel screw with plastic injection moulded head l premounted screw for quick installation Technical data Installation Anchor diameter Plate diameter Drill hole depth h 1 >_ Anchorage depth h ef >_ Screw drive Use categories acc. to ETA European Technical Approval (ETA) 8 mm 60 mm 80 mm 70 mm TORX T40 A, B, C ETA-04/0064 Characteristic loads Normal weight concrete C 12/15 acc. to EN kn Normal weight concrete C 16/20 - C 50/60 acc. EN kn Clay bricks (Mz) acc. to DIN kn Solid lime sandstone (KS) acc. to DIN EN kn Solid masonry (V) of lightweight concrete acc. DIN kn Vertically perforated clay bricks (Hlz) acc. to DIN kn Sand-lime perforated bricks (KSL) acc. to DIN EN kn Lightweight concrete hollow blocks (HbL) acc. DIN kn Regarding design loads the national safety factors are to be incorporated. Please observe the approval. Product range Insulation (mm) Product name Product code and length (mm) New build. 1) Renovation ²) 40 EJOT SDM T plus 8/60 U x EJOT SDM T plus 8/60 U x EJOT SDM T plus 8/60 U x EJOT SDM T plus 8/60 U x EJOT SDM T plus 8/60 U x EJOT SDM T plus 8/60 U x EJOT SDM T plus 8/60 U x EJOT SDM T plus 8/60 U x EJOT SDM T plus 8/60 U x EJOT SDM T plus 8/60 U x EJOT SDM T plus 8/60 U x EJOT SDM T plus 8/60 U x EJOT SDM T plus 8/60 U x EJOT SDM T plus 8/60 U x ¹ ) 10 mm adhesive ² ) 10 mm adhesive and 20 mm old render Packaging: 100 pieces each. 30
31 Solutions for special applications EJOT SDF K plus 8 U Specialist for rail systems on problematic substrates l approved for concrete, solid and perforated masonry l for installing fastening and holding rails l universal expansion zone for problematic substrates and high tolerances l premounted screw for quick installation l to compensate facade tolerances use spacers EJOT AS (page 26) Installation Technical data Anchor diameter Collar diameter Drill hole depth h 1 >_ Anchorage depth h ef >_ Screw drive Use category acc. to ETA European Technical Approval (ETA) 8 mm 16 mm 80 mm 70 mm TORX T30 A, B, C ETA-04/0064 Characteristic loads Normal weight concrete C 12/15 acc. to EN kn Normal weight concrete C 16/20 - C 50/60 acc. EN kn Clay bricks (Mz) acc. to DIN kn Solid lime sandstone (KS) acc. to DIN EN kn Solid masonry (V) of lightweight concrete acc. DIN kn Vertically perforated clay bricks (Hlz) acc. to DIN kn Sand-lime perforated bricks (KSL) acc. to DIN EN kn Lightweight concrete hollow blocks (HbL) acc. DIN kn Regarding design loads the national safety factors are to be incorporated. Please observe the approval. Product range Max. tolerance Product name Product code compensation (mm) and length (mm) 10 EJOT SDF K plus 8 U x EJOT SDF K plus 8 U x EJOT SDF K plus 8 U x EJOT SDF K plus 8 U x EJOT SDF K plus 8 U x EJOT SDF K plus 8 U x EJOT SDF K plus 8 U x EJOT SDF K plus 8 U x Packaging: 100 pieces each. Product will be phased out, availability on request. 31
32 Solutions for special applications Renovation of two-shell masonry When renovating old building fabric, it may be required by law to check the stability of the wall before installing ETICS. If necessary, the stability needs to be rebuilt at first. On two-shell wall constructions with facing shells, anchors from zinc-coated steel were used in the late 70 s for the first time. Their stability is often not safe due to advanced corrosion. With the EJOT VSD, the stability can be rebuilt. EJOT VSD Renovation anchor for prewall shells l cost-efficient rebuilding of the stability of facing shells in two-shell constructions l simple application: double expansion zone plugs simultaneously into the load-bearing wall and the facing shell l screw of non-corroding high-grade steel A4 l no mortar technique, quick handling l also applicable with low outside temperatures Technical data Installation Anchor diameter Drill hole depth h 1 >_ Anchorage depth h ef >_ Screw drive German DIBt Approval 8 mm 80 mm 70 mm TORX T30 Z Approved substrates Normal weight concrete C 12/15 acc. EN Normal weight concrete C 16/20 - C 50/60 acc. EN Clay bricks (Mz) acc. to DIN 105 Solid lime sandstone (KS) acc. to DIN EN 106 Solid masonry (V) of lightweight concrete acc. DIN Vertically perforated clay bricks (Hlz) acc. to DIN 105 Sand-lime perforated bricks (KSL) acc. to DIN EN 106 Lightweight concrete hollow blocks (HbL) acc. DIN Product range The EJOT VSD is installed in the centre of the stone. Minimum thickness of the facing shell: 115 mm. Distance between Product name Product code inner and outer shell (mm) and length (mm) 20 EJOT VSD 8 x EJOT VSD 8 x EJOT VSD 8 x EJOT VSD 8 x EJOT VSD 8 x EJOT VSD 8 x Packaging: 100 pieces each. 32
33 Solutions for special applications Weather shells of prefabricated building elements (precast concrete slab-type construction) were installed with steel tie rods in front of the load-bearing wall. Due to corrosion influences the stability can be endangered. Thus before renovating the facade with ETICS, the stability needs to be rebuilt. EJOT offers two convincing systems. Renovation rods for weather shells Renovation systems for rebuilding the stability of weather shells EJOT weather shell protection WSS l to rebuild the stability of weather shells of three-layered exterior wall panels l high-grade renovation specifically for the precast concrete slab-type construction l dry drilling method applicable l handling independent of the temperature (without mortar) l immediately stressable l with European Technical Approval (ETA-99/0007) EJOT weather shell protection KERI l cone anchor to rebuild the stability of weather shells of three-layered exterior wall panels l high-grade renovation specifically for the precast concrete slab-type construction l handling independent of the temperature (without mortar) l immediately stressable l approved by the German Deutsches Institut für Bautechnik (Z ) Product range Fastening thickness Product name Product code B <_ mm 120 EJOT WSS 24 x EJOT WSS 24 x EJOT KERI 40 x EJOT KERI 40 x Packaging: 100 pieces each. Our service for you: For safety reasons, rebuilding the stability of a weather shell or a facing shell should be calculated by an engineer. Our technical service is happy to help you choose the right renovation solution and delivers all details necessary. 33
34 Solutions for special applications EJOT special drill For optimum buckling loads in perforated bricks l special drill for perforated substrates l aggressive cutting angle for fast drilling without percussion l avoids bursting drill holes l with SDS-plus adapter l not to be used with percussion or hammer drilling Product range Total length/ Product name Product code use length (mm) 210 / 150 EJOT special drill 8.0 x 210/ / 200 EJOT special drill 8.0 x 260/ / 400 EJOT special drill 8.0 x 450/ Packaging: 1 piece each. EJOT spiral anchor Fastening solution for light attachments on ETICS facades l recommended load: max. 5 kg per mounting point l no thermal bridges l simply screw through the final rendering into the insulation (usually without pre-drilling), fasten a 4-5 mm screw (drive TORX T40) and fix the attachment Product range Installation Product name Product code EJOT spiral anchor Packaging: 10 pieces each, in box per 250 pieces. 34
35 Fasteners for ceiling insulation EJOT fastening solutions for ceiling insulation The energy optimisation of the building envelope is closely intertwined with insulating the ceiling of the lowest level. Especially next to unheated rooms like basements, garages, warehouses or passages... Moreover ceiling insulation is employed to improve acoustics. It is used for example as noise insulation in commercially used rooms or halls or as noise protection in shooting ranges. 35
36 Fasteners for ceiling insulation EJOT ceiling insulation screw DDS l fastening of ceiling and acoustic insulation l easy installation: drilling, screwing - done! l short anchorage depth l plastic injection moulded head with wood wool structure in colours beige or white for unobtrusive fastening l special service: coloured varnishing of the screw heads according to your preferences Technical data Installation Head diameter* Drill hole diameter Drill hole depth h 1 >_ Anchorage depth h ef >_ Screw drive Recommended substrate *incl. plastic injection moulding 25 mm 6 mm 30 mm 20 mm TORX T30 concrete Please observe the pull-out loads given in the approval of the system owner. Your EJOT team will be happy to help! Product range Insulation (mm) Product name Product code* and length (mm) head white head beige 25 EJOT DDS EJOT DDS EJOT DDS EJOT DDS EJOT DDS EJOT DDS EJOT DDS EJOT DDS EJOT DDS * screw head with plastic injection moulding Packaging: 100 pieces each. 36
37 Fasteners for ceiling insulation EJOT ceiling insulation plate DDT l to combine with ceiling insulation screw EJOT DDS to enlarge the plate diameter when it comes to soft insulation material l plate diameter: 70 mm l zinc-coated steel plate with coloured varnishing possible Product range Product name Product code plate white EJOT DDT Packaging: 100 pieces each. EJOT ceiling insulation anchor DDA l fastening of ceiling and acoustic insulation l easy installation: drill, hammer - done! l available in colours beige or white Technical data Head diameter Drill hole diameter Drill hole depth h 1 >_ Anchorage depth h ef >_ Recommended substrate 25 mm 8 mm 35 mm 25 mm concrete Please observe the pull-out loads given in the approval of the system owner. Your EJOT team will be happy to help! Product range Insulation (mm) Product name Product code and length (mm) colour white colour beige 50 EJOT DDA EJOT DDA EJOT DDA EJOT DDA EJOT DDA Packaging: 100 pieces each. 37
38 Fasteners for ceiling insulation EJOT metal insulation support DMH l fastening of hard insulation material for ceiling insulation l especially suitable for tougher fire protection requirements l easy installation: drill, hammer - done! l for gas concrete no predriling is necessary l metal support of stainless steel A2 to reduce thermal bridges l metal support is also available of zinc-coated steel Technical data Head diameter Drill hole diameter Drill hole depth h 1 >_ Anchorage depth h ef >_ Recommended substrates 35 mm 8 mm 60 mm 50 mm concrete, solid + perforated bricks Please observe the pull-out loads given in the approval of the system owner. Your EJOT team will be happy to help! EJOT metal insulation support plate DMH l to combine with metal insulation support EJOT DMH for soft insulation material l plate diameter: 80 mm l plate of stainless steel A2 to reduce thermal bridges l metal plate is also available of zinc-coated steel Product range Insulation (mm) Product name Product code and length (mm) zinc-coated steel stainless steel 30 EJOT DMH EJOT DMH EJOT DMH EJOT DMH EJOT DMH EJOT DMH EJOT DMT Packaging: 100 pieces each. 38
39 anchor 10 Building laws background EJOT anchor basics To harmonise the EU single market the EU Commission issued a directive on construction parts (89/106 EWG). It determines which building parts need to comply with the following essential requirements regarding their intended use: When processing the products, national requirements are to be regarded. This way, member states may explicitly incorporate specific national or regional requirements (e.g. different wind loads, safety factors, country-specific construction methods). l mechanical resistance and stability l safety in case of fire l hygiene, health and the environment l safety in use l protection against noise l energy economy and heat retention Working groups of the European Organisation for Technical Approvals (EOTA) have elaborated criteria on how to precisely prove these requirements are fulfilled for ETICS. These criteria and corresponding testing methods are stated in the European Technical Approval Guidelines (ETAG). For ETICS the following guidelines are relevant: l ETAG 004: external thermal insulation composite systems with rendering l ETAG 014: plastic anchors for fixing external thermal insulation composite systems with rendering l CUAP according to the relevant ETAG These guidelines are mandatory for all member states of the European Union (EU) as for well as those states of the European Free Trade Association (EFTA), that have signed the agreements of the European Economic Area (EEA), Iceland, Liechtenstein and Norway. The guidelines form the base for awarding European Technical Approval (ETA) for individual products. Construction parts with ETA and certificate of conformity may carry the CE mark, which enables the free movement of goods within the member states of the EEA. This way a uniform appraisal of construction parts and their fundamental technical specifications is ensured. Therefore each member state can assume without further testing that the construction part is generally suitable for the intended use if planning and construction are done correctly. Nevertheless, the CE mark may not be regarded as a quality mark. In terms of the EC guideline on construction parts, external thermal insulation composite systems are kits. The producer whose system receives an ETA is responsible for carefully choosing the single constituents. In accordance with ETAG 004, components of an ETICS are: l adhesive l insulation product l rendering system (including mesh reinforcement) l mechanical fixing devices (anchors, holding rails) l ancillary materials (e.g. corner strips and base profile) The approval lapses if components of various system owners are used. This constitutes a breach of the building code that leads to the loss of the warrantee by the owner and may have legal consequences. EJOT advises: Buy all system components exclusively from the provider of an approved system! An ETICS itself does not contribute to the structural stability of a building. Especially in renovation the stability of the wall construction has to be checked if an ETICS shall be installed. Since it has to carry the dead load of the insulation system after renovation, the stability might have to be rebuilt before attaching an ETICS. In particular this effects wall constructions of multiple shells (buildings with a prewall shell and precast concrete slab-type constructions). The guidelines assume a prospective useful life of ETICS of at least 25 years. In accordance with current practical experiences, the actual useful life may be much longer without having to fear fundamental quality impairment. In spite of that, a guarantee towards the system owner or single components cannot be inferred. 39
40 anchor 10 Good reasons for anchoring ETICS EJOT anchor basics Safe installation on old facades ETICS are often used for energetic insulation of old buildings. Do you know how much load the old render can actually carry? For decades it was exposed to weather and emissions. Soot, dirt and old paint reduce the bearing strength of the glue. Or single components are not compatible with the composition of the glue ( saponifying ). After installing a new ETICS building physics can change the bearing capacity of the old render (failure of old render) even after years. Regarding new buildings residues of release oil on concrete may cause difficulties. Cleaning a facade is complex and costly. Contaminated waste water has to be collected and professionally disposed. Moreover the old render is imbued when thoroughly cleaned. Highest structural stability When insulation boards are solely glued, the deadweight of an ETICS is passed onto the wall through shearing forces. The used glue is therefore the only connection between wall and insulation. Thanks to their specifically solid anchor plate and high characteristic loads, ejotherm plate anchors give your facade safe support. Through contact pressure the frictional bond between facade surface and adhesive as well as between adhesive and insulation board is steadily increased. This results in a higher stability of the whole system. Moreover anchors with steel screw or steel nail offer higher safety reserves. Safe is safe! But if insulation boards are additionally anchored, usually no special treatment of the facade is necessary. Only loose parts of the render, efflorescence and paint flaking off need to be roughly removed. Possible holes are filled. Eventually anchors provide safe support Weathered facade Z D Q Facade renovated with an ETICS Impact of anchoring: dead load of the system is passed on via adhesive and insulation plate anchors provide additional contact pressure Advantages: highest stability for the hole system anchor plates divert wind load highest security in case of wind loads 40
41 EJOT anchor basics 1Good reasons for anchoring an ETICS Highest security against hygrothermal impacts Hygrothermal influences like temperature changes and shrinkage lead to fluctuating material expansion that effect the inelastic adhesive joints. If solely glued there is a latent danger of the insulation boards to bulge due to lacking expansion possibility at the joints. The additional anchoring in the area of the joints as well as in the centre of the board results in a mechanical fixing of the system onto the wall and therefore reduces the risk of cracking plaster. Highest security against wind loads Wind loads affect in the opposite direction of the deadweight. They provide for a vertical tensile load onto the adhesive joint. Special importance is attached to the intersection of wall/ adhesive (new buildings) and of old render/adhesive (renovation) respectively as well as of adhesive/insulation. Particularly high wind loads exist l at higher buildings l at building edges l at free-standing buildings l in exposed areas l in coastal areas l in stormy weather warm outside cold outside Therefore: Climate scientists assume that the risk of heavy storms and grave damages will increase worldwide. EJOT anchors provide additional security! Additional fixing of the insulation boards with ETICS anchors by EJOT 41
42 anchor 10 Ways to perfect anchoring EJOT anchor basics Judginig the substructure The expansion zone of an anchor has to perfectly fit the wall substrate found at the building. It is the only way the anchor can optimally fulfil its function within the ETIC system. This is why carefully assessing the substructure is highly important. Determining the anchor type for the substrate After the substructure is determined, the proper anchor can be assigned with its approval since anchors with ETA are tested and approved for specific use categories. The following cases are possible: ETAG 014 (guideline for anchors in external thermal insulation composite systems) distinguishes standard substrates according to so-called use categories in order to facilitate the assignment of the matching anchor. Substrates Use category A: Normal weight concrete Use category B: Solid masonry Case 1: The anchor is approved for the determined building material category. The identified substrate is mentioned in the ETA of the anchor. The anchor may be used on the building without further testing. The loads given in the approval can be used offhand for calculating the necessary number of anchors. Where required, national safety factors need to be observed. Example: Solid lime sandstone was determined as wall substrate. This corresponds to use category B. The anchor has an ETA for use categories A and B. For solid lime sandstones, the ETA mentions a characteristic load of 1.2 kn. National rules require a security value of 3 for use category B. Therefore the anchor can be calculated having a design load of 1.2 kn : 3 = 0.4 kn without further testing on the building. Case 2: The anchor has no approval for the determined building material category. Use category C: Hollow or perforated masonry Use category D: Lightweight aggregate concrete If the determined substrate at the building does not belong to a use category for which the anchor is approved according to the ETA, the anchor may not be used on this object. In this case, the usability of the anchor cannot be proven through pull-out tests. Example: Vertical coring bricks were determined as wall substrate. This corresponds to use category C. An anchor only approved for use categories A and B may not be used. Use category E: Autoclaved aerated concrete 42
43 1 EJOT Ways to perfect anchoring Case 3: The anchor is generally approved for the determined building material category. But the identified substrate is not explicitly named in the ETA of the anchor. The anchor may be used if its usability is proven through tests on the building. The object specific characteristic loads are determined through pull-out tests as described in the ETA. When deducting the design load national safety factors need to be incorporated. Example: Perforated lime sandstone was determined as wall substrate. This corresponds to use category C. The anchor has an ETA for use categories A, B, C and D. Nevertheless, perforated lime sandstone is not explicitly named in the ETA. Pull-out tests with this anchor on the object result in a characteristic load of 1.5 kn. National rules require a security value of 3 for use category C. The anchor can be calculated having an design load of 1.5 kn : 3 = 0.5 kn. Case 4: The anchor is generally approved for the determined building material category. The identified substrate is already mentioned in the ETA of the anchor, but the gross density or the compression strength of the stone differs from the declaration of the approval. In principle this case corresponds to case 3. The usability for the substructure can be proven through tests on the building. Special case: Weather shells of concrete (precast concrete slab-type construction) are assigned to use category A. With any ejotherm anchor the loads may be calculated employing tests on the building. EJOT advises: l The ejotherm STR U (as plate anchor) as well as the ejotherm SDK U (for fastening rails) have a European Technical Approval for all building material classes. Many substrates are already tested for the approval and named in the ETA. Therefore usually no additional tests are necessary. l Should tests on the building site be needed, you have EJOT s service at your hand. anchor basics Further criteria for choosing the perfect anchor If in principal several anchor types are applicable in the found building material, further assessment criteria can be employed. Example ejotherm STR U 100% setting control 3 1) Homogenous insulation surface 3 Even rendering 3 Permanent contact pressure 3 Less work thanks to premounted expansion element 3 Installation behaviour ++ Loads ++ Reduction of thermal bridges + Range of use 2 ++ Anchorage depth When applying the STR principle for countersunk installation. 2 A bigger range of application offers more security regarding fluctuating substrate qualities and mixed masonry. 3 Please note possible differences between effective and nominal anchorage depth when comparing with other products. Additonal plates depending on the application Depending on the application, our ETICS anchors are combined with additional plates. The additional plates are very simple to use and are available in various diameters. They are put on the plate anchor like a washer. The further installation is processed as usual. In which case a specific additional plate is applied, depends on the used insulation and the system configuration. Crucial are the specifications of the system owner. Note: Additional plates are system components of the anchor. They are tested accordingly and described in the approval of the anchor. Therefore plate anchors may only be combined with the matching additional plates by the same manufacturer. 43
44 anchor 10 Ways to perfect anchoring EJOT anchor basics Determining the necessary anchor length The correct determination of the anchor length is an important prerequisite to obtain the highest fastening safety possible. The object specific preconditions always have to be taken into account. But determining the necessary anchorage length itself is easy: nominal anchorage depth h nom + tolerance compensation t tol + insulation thickness h D = necessary anchor length l D Determining the necessary number of anchors The necessary number of anchors has to be determined for each building individually. According to new European and national wind load standards several factors have to be incorporated. Amongst the most essential influences are the building construction (height, ground plan, profile) as well as the surroundings of the building. Exposed conditions in coastal areas, on mountains or outside closed housing areas normally lead to significantly higher wind loads. Details and actual maps with zones of different wind loads are part of national standards. h 1 h ef = h nom t tol h D From the system point of view the anchor usage is increased by the bearing load of the used insulation board as well as the characteristic load and the plate stiffness of the employed anchors. Therefore the working guidelines of the ETICS provider have to be observed. Generally speaking: the higher the building and the more exposed its surrounding area, the higher the necessary number of anchors. On the other hand high-quality anchors often mean a lower usage of anchors per square metre and thus save material cost and working hours. h 1 = drill hole depth h ef = effective anchorage depth h nom = nominal anchorage depth (>_ h ef ) t tol = tolerance compensation = insulation thickness h D Notes: If no other specifications are given, the nominal anchorage depth h nom is equal to the effective anchorage depth h ef. The tolerance compensation consists of: thickness of old render (if existent, the old render often is approx. 20 mm thick) + thickness of the adhesive joint after pressing the insulation boards against the wall (as a rule approx. 10 mm)* + additional compensation of facade unevenness* = tolerance compensation t tol Correct processing is crucial for the function of the anchor The position of the anchor results from the anchor scheme of the ETIC system owner. Common anchorage alignments are for example: l alignment of anchors for insulation boards with formats 1000 x 500 mm, e.g. rigid foam plates of polystyrene and 800 x 625 mm, e.g. mineral wool plates (table 1) l alignment of anchors for insulation boards with formats 1000 x 200 mm, e.g. lamella plates of mineral wool (table 2) Anchors should always be installed in the area of the adhesive, so that they can support the adhesive joint by means of contact pressure in the best way possible. If during the energetic renovation there is a larger facade unevenness to compensate, it may be necessary to employ different anchor lengths. * Facade tolerances are eventually compensated through the actual total thickness of the adhesive mortar. 44
45 1 EJOT Ways to perfect anchoring anchor basics Table 1 Table 2 Anchors per square metre Anchor alignment Anchors per square metre Anchor alignment
46 anchor 10 Ways to perfect anchoring EJOT anchor basics Drilling methods Depending on the drilling machine and the hammer drill respectively, the following drilling methods are possible: l rotary drilling - without percussion l percussion drilling - many percussions with low energy l hammer drilling - few percussions with high energy rotary drilling percussion drilling hammer drilling Standard carbide drill for percussion and hammer drilling EJOT special drill for clean rotary drilling The drilling method is dependent upon the individual anchorage substructure. It is given in the following table. Use category A B C D E Drilling method percussion/ rotary drilling without hammer drilling percussion 46
47 EJOT anchor basics Ways to perfect anchoring 1EJOT advises: When drilling in rotary mode (without percussion), use our special drills to achieve a clean hole in a short time. Drills are wearing parts. Their durability depends on the solidness of the substructure: The harder it is, the higher the abrasion. To achieve an efficient work progress, drills should be exchanged in time. When drilling, please exactly follow the specified installation values of the individual anchor type (especially the minimum drilling hole depth). The exact geometry of the drill hole is important for the bearing capacity of the anchor. Therefore always drill orthogonally and never change direction while drilling. This is especially important with regards to soft substrates. Before inserting the anchor clean the hole from drill dust by pulling out the drill several times. Plate moves in too deeply With regards to plate anchors the anchor plates are either installed countersunk into the insulation board following the EJOT STR principle or plain with the surface on the insulation exterior (always in combination with additional plates). When installing plain with the surface it should be regarded that the upper side of the anchor plate forms one level with the upper side of the insulation. When the plate moves in too deeply, the cavity needs to be levelled out before installing the mesh. This leads to heightened plaster in the area of the plate and bears the risk of cracking plaster. When the plate does not enter deep enough, a thicker mesh layer has to be installed over the whole facade in order to achieve the minimum render thickness over the anchor plates. This results in higher costs. Plate not deep enough EJOT advises: When using the EJOT STR principle, the anchor plate is quickly and cleanly countersunk into the insulation and covered with an STR cap. This way a smooth and homogenous insulation surface as basis for an even rendering is established. No additional work for levelling out the anchor plates is needed. Moreover, the anchor plates are detached from the rendering. Perfect: installation of ejotherm STR with cap 47
48 EJOT Building Fasteners There for you worldwide! EJOT AUSTRIA GmbH Grazer Vorstadt 146 A 8570 Voitsberg ph. +43 (31 42) fax +43 (31 42) e mail: [email protected] internet: EJOT FESTESYSTEM A/S Aslakveien 20A N 0701 Oslo ph. +47 (23) fax +47 (23) e mail: [email protected] internet: EJOT SLOVAKIA, s.r.o. Juzná trieda 82 (Areál VSS) SK Košice ph (55) fax (55) e mail: [email protected] internet: EJOT & AVDEL SYSTEM AB Sandtagsvägen 7 S Örebro ph. +46 (19) fax +46 (19) e mail: info@ejot avdel.se internet: avdel.se UAB EJOT Baltic Titnago g. 19 LT Vilnius ph (5) fax +370 (5) e mail: [email protected] EJOT BAUBEFESTIGUNGEN GmbH In der Stockwiese 35 D Bad Laasphe ph. +49 (27 52) fax +49 (27 52) e mail: [email protected] internet: EJOT Benelux NV Grote Bergen 26 B-2830 Heindonk-Willebroek ph. +32 (03) fax +32 (03) e mail: [email protected] EJOT Bulgaria EOOD & Co. KD Grivishko Shosse Number 1 Complex Industrialen BG-5800 Pleven ph (64) fax +359 (64) e mail: [email protected] EJOT CZ spol. s.r.o. Zdĕbradská 65 CZ Řič any Jažlovice ph (3 23) fax +420 (3 23) e mail: [email protected] internet: EJOT Danmark APS Karisevej 72 DK 4690 Haslev ph. +45 (56) fax +45 (56) e mail: [email protected] internet: EJOT Fastening Systems (Taicang) Co., Ltd. 88, Zhenghe Road (East), Taicang, Jiangsu, PC ph. +86 (512) fax +86 (512) e mail: [email protected] internet: EJOT The Quality Connection EJOT FRANCE S.A.R.L. Z.l. rue du Climont F Villé ph. +33 (3 88) fax +33 (3 88) e mail: [email protected] internet: EJOT HUNGÁRIA Kft. Ócsai út 1 3 H 1239 Budapest ph. +36 (1) fax +36 (1) e mail: [email protected] internet: EJOT Ibérica S.L. Pol. P 29, C/ Azuela 78, nave 4 S Collado Villalba (Madrid) ph. +34 (91) fax +34 (91) e mail: [email protected] EJOT ITALIA srl. Via Migliarone, n. 21/bis I Alpignano Torino ph. +39 (0 11) fax +39 (0 11) e mail: [email protected] internet: EJOT Middle East FZE Sharjah Airport International Free Zone VAE-P.O. Box ph (6) fax +971 (6) e mail: [email protected] EJOT ROMÂNIA S.R.L. Sos. Bucuresti-Pitesti nr.161 bis RO Stefanesti ph. +40 (2 48) fax +40 (2 48) E Mail: [email protected] EJOT d.o.o. Sarajevo Rajlovacka b.b. BiH Sarajevo ph (33) fax +387 (33) e mail: [email protected] EJOT SCHWEIZ AG Uttwiler Straße 3 CH 8580 Dozwil ph. +41 (71) fax +41 (71) e mail: [email protected] EJOT SPOJNA TEHNIKA d.o.o. Franje Luč ić a 23/3 HR Zagreb ph (1) fax +385 (1) e mail: [email protected] EJOT Technika Mocowań Spółka z ograniczoną odpowiedzialnością Sp. k. Ul. Jez owska 9 PL Ciasna ph. +48 (34) fax +48 (34) e mail: [email protected] EJOT Tehnika Spajanja d.o.o. Belgrad Autoput Beograd Novi Sad 296X SCB Zemun ph (11) fax +381 (11) e mail: [email protected] internet: EJOT TEZMAK Cebeci Cad. No. 84 TR Küçükköy Istanbul ph. +90 (2 12) fax +90 (2 12) e mail: info@ejot tezmak.com internet: tezmak.com EJOT U.K. Ltd. Hurricane Close Sherburn Enterprise Park Sherburn in Elmet GB Leeds LS25 6PB ph. +44 (19 77) fax +44 (19 77) e mail: [email protected] internet: TOV EJOT Ukraina Kurenevskij proulok, b. 17, UA 04073, Kiev ph. +38 (0 44) fax +38 (0 44) OOO EJOT WOSTOK Projektiruemij Proezd Nr Nagatinskij Terminal RUS , Moscow ph. +7 (4 95) fax +7 (4 95) e mail: [email protected] internet: For all other countries, please contact our headoffice in Germany, EJOT Baubefestigungen GmbH. 419 E/01.08
49 ETICS Anchors Simply faster, safer and more efficient!
50 Anchor table EJOT fastening systems for ETICS a solution for everything. For the anchor table simply fold.
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
HUS-HR, CR Screw anchor, stainless steel
HUS-HR, CR Screw anchor, Anchor version HUS-HR 6 / 8 / 10 / 14 Stainless steel concrete Screw with hexagonal head HUS-CR 10 Stainless steel concrete screw with countersunk head Benefits - High productivity
Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+
Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+ The wall sleeve The wall sleeve a largely unnoticed but very important sealing part. Wall sleeves
WATERPROOFING OF WET ROOMS
WATERPROOFING OF WET ROOMS Waterproofing under tiles For longterm enjoyment of a wetroom area a complete and resistant waterproofing system is an important precondition. Most tiles are by themselves waterproof
fischer Test Report Fixing Tests for Wienerberger Porotherm blocks
fischer Test Report Fixing Tests for Wienerberger Porotherm blocks CONTENTS. Test Parameters... Substrates Tested Wienerberger Porotherm 90 &. Fixings Products Tested... Fischer Nylon UX Plug... Fischer
RELAZZO DECKING THE TERRACE. INSTALLATION GUIDE. Construction Automotive Industry. REHAU R20680 EN 05.2015 www.rehau.com/relazzo
Construction Automotive Industry RELAZZO DECKING THE TERRACE. INSTALLATION GUIDE REHAU R20680 EN 05.2015 www.rehau.com/relazzo Scan the QR code and learn more: RELAZZO DECKING THE TERRACE. Installation
12.1 Schlüter -KERDI-BOARD
I n n o v a t i v e p r o f i l e s 12.1 Schlüter -KERDI-BOARD S u b s t r a t e U N I V E R S A L S T R U C T U R A L P A N E L, B O N D E D W A T E R P R O O F I N G Application and Function Schlüter
BETONYP building boards. The modern way of living.
BETONYP building boards The modern way of living. Tough for 30 years. Healthy, debarked pine wood and cement: the raw materials used to produce one of our most successful products for more than three decades.
Rockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
(English language translation, the original version is in French language) SPIT HIT M. Société SPIT Route de Lyon F-26501 BOURG-LES-VALENCE France
Centre Scientifique et Technique du Bâtiment 84 avenue Jean Jaurès CHAMPS-SUR-MARNE F-77447 Marne-la-Vallée Cedex 2 Tel. : (33) 01 64 68 82 82 Fax : (33) 01 60 05 70 37 Autorisé et notifié conformément
Discussion on Products under the Scope of EN 1090-1 and proposed CEN/TR to clarify the scope
CEN/TC 135 N 686 European Committee for Standardization Comité Européen de Normalisation Europäisches Komitee für Normung CEN/TC 135 Execution of steel structures and aluminium structures N 686 Secretariat:
INNOVATIONS. Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems. A Company of the SAARGUMMI Group
INNOVATIONS Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems A Company of the SAARGUMMI Group OUR SOLUTION TO REFURBISH ROOFS FOR LONG-TERM DURABILITY Quality and Experience from the Innovation
HUS-HR Stainless steel Concrete Screw A4 316. CE conformity. Corrosion resistance. European Technical Approval
HUS-HR screw anchor Anchor version Benefits HUS-HR Stainless steel Concrete Screw Quick and easy setting Low expansion forces in base materials Through fastening Removable Forged-on washer and hexagon
HUS-A 6 / HUS-H 6 / HUS-I 6 / HUS-P 6 Screw anchor in precast prestressed hollow core slabs
HUS-A 6 / HUS-H 6 / HUS-I 6 / HUS-P 6 Screw anchor in precast Anchor version HUS-A 6 Screw with hex head HUS-H 6 Screw with hex head HUS-I 6 Screw with hex head Benefits - Quick and easy setting - Low
Composite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
HORIZONTAL INSTALLATION
THERMO/SOLAR Žiar s.r.o. MANUAL FOR INSTALLATION PV SUPPORTING FRAMES HORIZONTAL INSTALLATION Technical alternation reserved A1410 1 12/2014 CONTENT ORD.NO. PAGE Mounting information 3 Mounting, flat roof
Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko
INSTALLATION MANUAL Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko Ventilated Notified entity Building Technical and Research Institute Prague notification no. 1020 This instruction refers to double-layer
HVU with HAS/HAS-E rod adhesive anchor
HVU with HAS/HAS-E rod HVU with HAS/HAS-E rod adhesive anchor Mortar system Benefits Hilti HVU foil capsule HAS HAS-R HAS-HCR rod - suitable for non-cracked concrete C 20/25 to C 50/60 - high loading capacity
EJOT Spiralform. The thread formers for metal. EJOT The Quality Connection
EJOT Spiralform The thread formers for metal EJOT The Quality Connection Imprint Editor: EJOT GmbH & Co. KG Industrial Fasteners Division D 57319 Bad Berleburg Layout and Realisation: EJOT GmbH & Co. KG
European technical approval ETA-12/0208
- Original version in German language Handelsbezeichnung Trade name termoz SV II ecotwist Zulassungsinhaber Holder of approval Zulassungsgegenstand und Verwendungszweck Generic type and use of construction
HUS-HR, CR Screw anchor, stainless steel
HUS-HR, CR Screw anchor stainless steel HUS-HR, CR Screw anchor, stainless steel Anchor version HUS-HR 6 / 8 / 10 / 14 Stainless steel concrete Screw with hexagonal head HUS-CR 10 Stainless steel concrete
HS-Steel-Classic. Curing chambers for the concrete block industry in a proven steel version
ANLAGENTECHNIK HS-Steel-Classic Curing chambers for the concrete block industry in a proven steel version + special galvanising + simple assembly due to snap-in connections and building kit system We build
0845 0098 980 www.nicholsonsts.com
0845 0098 980 www.nicholsonsts.com ROOFTRAK The IFP is revolutionising the way we fix things to roofs. Technical Director of a leading UK roofing system manufacturer The ROOFTRAK-IFP A revolutionary solution
European Technical Approval ETA-12/0500
ETA-Danmark A/S Kollegievej 6 DK-2920 Charlottenlund Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet www.etadanmark.dk Authorised and notified according to Article 10 of the Council Directive 89/106/EEC
PC-Concrete Injectable Concrete Anchoring and Repair System
PC-Concrete Injectable Concrete Anchoring and Repair System DESCRIPTION: PC-Concrete is a two component (1:1 ratio), 100% solids, high modulus, structural epoxy paste. PC-Concrete is a solvent free, no
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
Scope of EN 1090-1 Clarification Document
Scope of EN 1090-1 Clarification Document This document has been submitted to the European Commission as the UK view on the scope of EN 1090-1. After discussions, including with the European Technical
Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.
Roofing Systems There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. BUR (Built-Up Roofing) Built-Up-Roofing, BUR is a roof that
HUS-V Screw anchor. HUS-V Screw anchor. Basic loading data (for a single anchor) Mean ultimate resistance
HUS-V Screw anchor Anchor version HUS-V 8 / 10 Carbon steel concrete screw with hexagonal head Benefits - High productivity less drilling and fewer operations than with conventional anchors - Technical
Product Data Sheet ROCKPANEL Rockclad
Product Data Sheet ROCKPANEL Rockclad Durable - Xtreme - FS-Xtra United Kingdom 1 Product description ROCKPANEL boards are prefabricated compressed mineral wool boards with synthetic binders. The surface
Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...
Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major
ICC-ES Evaluation Report
ICC-ES Evaluation Report ESR-2369 Reissued May 1, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council
Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing
Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD The universal substrate for tiles Flat. Level. Plumb. Square. No matter the quality, cost, or extravagance of
The answer. Cost-Benefit Ratio of different construction depths. Comparison of U f -values. profine GmbH Kömmerling Kunststoffe
Order No. 2 02 130270-0310.KA profine GmbH Kömmerling Kunststoffe Postfach 2165 66929 Pirmasens Germany Tel. +49 6331 56-0 Fax +49 6331 56-2475 E-mail: [email protected] Internet: www.koemmerling.de
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders
How To Make An Oriented Strand Board
ABOUT COMPANY Mission Provide solutions to enchance customers product value. Vision - To be a leader among wood based panel producers in the region. Values Innovation, integrity and team commitment. BOLDERAJA
ETAG 004 EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS WITH RENDERING
European Organisation for Technical Approvals Europäische Organisation für Technische Zulassungen Organisation Européenne pour l Agrément Technique Edition March 2000 Amendment June 2008 GUIDELINE FOR
Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades
Construction Sika For Sealing and Waterproofing Construction Gaps in Building Façades Waterproof and Airtight Flexible Seal Controlled Vapour Diffusion Bonds to any Building Substrate Prevents Interstitial
Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests
Product Data Sheet Edition 05/12/2014 Identification no: 020204030010000044 Sikadur -41 CF Rapid 3-part thixotropic epoxy patching mortar Construction Product Description Uses Characteristics / Advantages
Saferand easierinstallation
EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little
European Technical Approval ETA-10/0200
Deutsches Institut für Bautechnik Anstalt des öffentlichen Rechts Kolonnenstr. 30 B 10829 Berlin Germany Tel.: +49(0)30 787 30 0 Fax: +49(0)30 787 30 320 E-mail: [email protected] Internet: www.dibt.de Mitglied
PART E SPECIFICATIONS
PART E SPECIFICATIONS Page 1 of 5 PART E - SPECIFICATIONS GENERAL E1. APPLICABLE SPECIFICATIONS, STANDARD DETAILS AND DRAWINGS E1.1 The City of Winnipeg Works and Operations Division Standard Construction
172 Holesaws Overview Bosch Accessories for Power Tools 09/10. 189 Diamond holesaw. with Power-Change adapter. 190 Diamond drill bits
Holesaw 172 Holesaws Overview Bosch Accessories for Power Tools 09/10 Overview 178 Progressor holesaw 189 Diamond holesaw 196 Hole cutters 183 Sheet Metal holesaw 190 Diamond drill bits 186 Multi Construction
Rockwool Cladding Roll
Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F
Hilti HIT-HY 200 with rebar
Hilti HIT-HY 200 Injection mortar system Benefits Hilti HIT- HY 200-A 500 ml foil pack (also available as 330 ml) Hilti HIT- HY 200-R 500 ml foil pack (also available as 330 ml) Static mixer rebar BSt
Removable Aluminium posts
Post Solent Sail Shades Ltd 120 Billington Gardens Hedge End Southampton SO30 2RT Tel/Fax: 01489 788243 www.solentsailshades.co.uk Email: [email protected] Removable Aluminium posts Single Pole
Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale
Installation information METTLER TOLEDO MultiRange DW150 / DW150T wall scale DW150 / DW150T wall scale Contents Contents Page 1. Installation... 2 1.1 Preparatory work... 2 1.2 Installing the wall plates
1.2.1 1.1.8 PRODUCTBLADEN GT ROCKPANEL STRUCTURE
1..1 1.1.8 PRODUCTBLADEN SHEETS GT page 1 to 6 Rockpanel Structure is a very durable panel with a lightly textured finish, specially developed for use in cladding, fascia, soffit applications. The basic
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
Detailing of Reinforcment in Concrete Structures
Chapter 8 Detailing of Reinforcment in Concrete Structures 8.1 Scope Provisions of Sec. 8.1 and 8.2 of Chapter 8 shall apply for detailing of reinforcement in reinforced concrete members, in general. For
AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY
PERFORMANCE CEILINGS M ore s c op e f or i n n ovat i on AMF Line; wall absorbers Wall mounted acoustic designs MADE IN GERMANY 138568_Prospekt Wandabsorber_GB int.indd 1 Acoustic elements on the wall
Hanson Building Products. precast basement solutions
Hanson Building Products precast basement solutions Hanson Building Products Basement Systems Add an extra dimension and combine the inherent flexible, structural and waterproof properties of concrete
Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions
ABS-Lock X / X - SR Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions The ABS-Lock X system was developed to provide both a secure single anchorage point for
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
Surface Engineering Solutions Rebuild, Repair and Protect Industrial Equipment
Surface Engineering Solutions Rebuild, Repair and Protect Industrial Equipment Whatever You Rebuild, Repair and Protect...... Find the Right Solution! Henkel's Solutions for all Surface Engineering Needs
Mandate M/116 MASONRY AND RELATED PRODUCTS
Mandate M/116 Page 1 sur 19 Mandate M/116 MANDATE TO CEN/CENELEC CONCERNING THE EXECUTION OF STANDARDISATION WORK FOR HARMONIZED STANDARDS ON CReatE MASONR AND RELATED PRODUCTS RELATED TO THE FOLLOWING
Pipe Clamps and Accessories
Products 4.0 Products 4.1 Connection options to pipe clamps with Triple-Thread Connector NT 3G (M16, M10, M8) 4.2 Connection options to pipe clamps with Triple-Thread Connector NT 3G (3/8", M12, M10) 4.3
Operating Instructions
Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4
European Technical Assessment. ETA-02/0020 of 22 September 2015. English translation prepared by DIBt - Original version in German language
European Technical Assessment ETA-02/0020 of 22 September 2015 - Original version in German language General Part Technical Assessment Body issuing the European Technical Assessment: Trade name of the
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors
Installation Manual Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors SW602206 Rev B Table of Contents Chapter 1: Safety Warning... 3 Chapter 2: Kit Contents... 4 Included in Kit...
MERO Floor Systems - CleanRoom
MERO Floor Systems - CleanRoom Innovative solutions out of one hand Development Access floor Consulting Hollow floor Planning Floor covering and Manufacturing Installation Installation Services Floor systems
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal
SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS
NOISE TECHNICAL FACT SHEET FACT SHEET 5 SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS The sound insulation of exterior walls and roof-ceiling systems refers to their ability to reduce external
HSL-3 Heavy duty anchor carbon steel. Anchor Fastening Technology Manual HSL-3. Heavy duty anchor. Version 2015-09 09 / 2015 1
Anchor Fastening Technology Manual HSL-3 Heavy duty anchor HSL-3 Heavy duty anchor Version 2015-09 09 / 2015 1 HSL-3 Heavy duty anchor, Anchor version Sizes Benefits HSL-3 Bolt version Threaded rod version
MultiPost-AP anchorage device
MultiPost-AP anchorage device MultiPost anchorage point Type 1 Fixing on reinforced concrete with large, 360 rotating stainless steel lifting eye for the simultaneous securing of max. 2 persons. This can
ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.
Two-component flexible, waterproofing and protective cementitious grout. 1504-2 PI-MC-IR Technical features Two-component grout, based on cements, selected aggregates, special additives and synthetic polymers
Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments
Cannon T4 Modular Data Centres For Outside Deployment & Challenging Environments A high performance, full specification Data Centre, up to Tier 4* resilience, instantly deployable A highly secure Data
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
Solid shape molding is not desired in injection molding due to following reasons.
PLASTICS PART DESIGN and MOULDABILITY Injection molding is popular manufacturing method because of its high-speed production capability. Performance of plastics part is limited by its properties which
Sealing & Bonding Sika solutions for Window Installation
Sealing & Bonding Sika solutions for Window Installation Sika s Comprehensive Fenestration Competence Benefit of our solution Globally, growing requirements to save energy and to utilize natural resources
Flat Roofing Made www.ejot.co.uk Simple The EJOT Range includes:- Flat roofing fastening system for fixing thermal insulation and
Flat Roofing Made Simple EJOT U.K. Limited, Hurricane Close, Sherburn Enterprise Park, Sherburn-in-Elmet, Leeds LS25 6PB Tel: +44 19 68 40 Fax: +44 19 68 41 Email: [email protected] www.ejot.co.uk The EJOT
Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
Fall Protection Solutions
P R O V I D I N G S A F E T Y S O L U T I O N S W O R L D W I D E Fall Protection Solutions COLLECTIVE PROTECTION KEEGUARD FREE STANDING GUARD RAIL APPROVED BY CERAM AND APAVE KEE DOME SKYLIGHT FALL PROTECTION
CEILING SYSTEMS. CI/SfB (35) Xy April 2006. [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design
CEILING SYSTEMS [Between us, ideas become reality.] CI/SfB (35) Xy April 2006 ULTIMA CANOPY Data sheet Acoustic performance meets High Design ULTIMA CANOPY Installation Instructions I. GENERAL 1. Product
Lenntech. 1000 psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503
1 User s Guide to: Phoenix Vessel Technology Limited 1000 psi End port pressure vessels 2.5. Model number: 1503 Lenntech [email protected] Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Phoenix
AA Solar and Sun Power Plus
AA Solar and Sun Power Plus www.aasolar.co.nz www.sunpowerplus.co.nz -1- Contents Chapter Title Page 1 General information 3 2 Safety and Installer Responsibilities 4 3 Technical Specifications 5 4 Tools
After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE
86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is
building applications copper - redefined
building applications copper - redefined copper - redefined The task The development of an innovative tube for the future: economical, environmentally friendly, ecological, completely safe and easy to
STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES
ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.
SOLAR SOLUTIONS BONDED MOUNTING TECHNOLOGY. DURABLE BONDING OF PV MODULES TO MOUNTING SYSTEMS WITH Sikasil
SOLAR BONDED MOUNTING TECHNOLOGY DURABLE BONDING OF PV MODULES TO MOUNTING SYSTEMS WITH Sikasil ADDED VALUE BY BONDING OF MODULES TO MOUNTING SYSTEMS SUITABLE IN PRODUCTION AND ON-SITE NOWADAYS PHOTOVOLTAIC
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
Hilti HIT-HY 150 MAX with rebar
Hilti HIT-HY 150 MAX Injection mortar system Hilti HIT- HY 150 MAX 330 ml foil pack (also available as 500 ml and 1400 ml foil pack) Static mixer rebar BSt 500 S Benefits - suitable for non-cracked and
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
High-performance, 2-part epoxy anchoring adhesive
Product Data Sheet Edition 27/04/2009 Revision no: 0 Identification no: 01 04 02 06 001 0 000030-3+ -3+ High-performance, 2-part epoxy anchoring adhesive Construction Product Description Uses Solvent-free,
VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A
Technical Data Manual Model Nos. and pricing: see Price List Vacuum tube collector based on the heat pipe principle For the utilisation of solar energy VITOSOL r 200-T SP2A Product may not be exactly as
Customer Service 800.780.8889 or visit us online at smithnoble.com. Wood Shutters. Step by Step Installation. Troubleshooting Tips
reflect your style TM Customer Service 800.780.8889 or visit us online at smithnoble.com Wood Shutters Step by Step Installation Troubleshooting Tips Easy Care Instructions STEP 1 Your New Shutter Thank
How To Buy A Designo Grille
anal ompact anal Plus 1 2 3 1. omplete anal Plus underfloor unit 2. Heat exchanger and inside finish of the duct in dark grey 3. Enlarged range of grilles anal Plus Operating principal Options Flexible
BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"
BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP" Sl. 1 DISMANTLING WORK 1.1 Stripping off worn out plaster (outside and inside) and raking out joints
Baumit Renders for Porotherm Masonry. Application Guidelines. n Light and easy application n Tried and tested
Renders for Porotherm Masonry Application Guidelines n Light and easy application n Tried and tested Porotherm is a Wienerberger Group brand Ideas with a future Renders for Porotherm Masonry International
WHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow
Machine devices, jig devices
Machine devices, jig devices 853 K0697 Rolled thread studs DIN 6379 Material: Tempered steel. KIPP Rolled thread studs DIN 6379 Order No. D L B1 B2 Approx. weight g Surface finish: Thread rolled. Class
MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS
MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS May 29, 2013 Revision B Structural Guideline for Design and Installation Holes in Composite Floor Slab Terminal 3, Departure Level
STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
Important Information
Single Door Quadrant Instruction Manual ESQ Important Information Toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed according to
SikaProof A Technology
SikaProof A Technology The fully bonded waterproofing system Keep your basements durably and securely watertight What is SikaProof A? How does it work? Where can it be used? What are the advantages of
Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual
BR BO-01-02 Effective from June 1, 2000 Revision: March 26, 2002 Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual (Unofficial Manual) Technical Appraisal Department, Building