Technical Manual. Hawker Life IQ TM. Single phase and 3-phase chargers
|
|
|
- Archibald Farmer
- 9 years ago
- Views:
Transcription
1 Technical Manual GB Hawker Life IQ TM Single phase and 3-phase chargers 1
2 Technical manual Life IQ TM - Single phase and 3-phase chargers CONTENTS AIMS OF THIS MANUAL...2 INFORMATION...2 WARRANTY... 2 RECOMMENDATIONS...2 ELECTRICAL SAFETY... 2 LIMITATIONS OF USE... 3 PRODUCT RECYCLING DESTRUCTION...3 MODIFICATIONS AND IMPROVEMENTS...3 RECEIVING STORAGE...3 SPARE PARTS... 3 INFORMATION PLATE... 3 GLOSSARY... 3 EEC DECLARATION OF CONFORMITY... 3 DESCRIPTION... 4 INTRODUCTION... 4 FEATURES... 4 EXTERNAL COMPONENTS... 4 CONTROL PANEL... 4 THE MENUS... 5 ACCESS TO THE MENUS... 5 MEMORISED DATA... 5 STATUS... 5 USB... 5 CONFIGURATION... 5 PARAMETERS... 6 PASSWORD... 6 INFORMATION... 6 USING THE CHARGER... 6 UNPACKING...6 MECHANICAL INSTALLATION... 6 ELECTRICAL CONNECTIONS... 7 FACTORY SETUP... 8 CHARGING THE BATTERY... 8 HISTORICAL DATA PER CHARGE... 9 CHARGER HISTORICAL DATA...9 MESSAGES AND FAULT CODES... 9 INFORMATION GOALS OF THIS MANUAL This manual is aimed at any authorized personnel wanting to use a single phase and 3-phase Life IQ TM charger to recharge lead acid motive power batteries (vented, Hawker XFC TM, Gel or Water Less / Water Less 20 ranges) This manual contains information on: Charger functionality. Use and setting of charger parameters. Technical specifications of the Life IQ chargers. EnerSys intends to provide clear and simple information in this manual, and assumes no responsibility for misunderstanding or improper interpretation of the information. The owner of the equipment is required to preserve this manual during the life of the equipment and to transfer said manual to any subsequent purchaser. WARRANTY Warranty is offered by the manufacturer based on local regulations. Please contact your local distributor for further information. RECOMMENDATIONS Recommendations for safe operation This manual should be carefully read, prior to using the equipment, by anyone intending to use the charger. The Life IQ: Must not have its air circulation impaired in any way, primarily around the air inlet areas. Dust accumulation must be removed every 12 months. Must be used within its protection norms, and never be directly in contact with water. Must be used only within the temperature range specified in the technical specifications. Internal connection torques must be checked once a year. Must not be installed on a surface subject to high vibration levels (proximity of motors, compressors, etc.). Must not be installed close to the batteries in order to avoid any gassing that could damage it prematurely. Must not be installed in arduous environments such as: Harbour applications (saline air) Close to cold stores External locations with exposure to wind and rain. Operator safety All proper precautions must be observed when the equipment is used in areas where accidents are possible. Ensure proper ventilation when the charger is used with lead-acid batteries, due to gassing. Never disconnect the battery during the charging process. General warnings Requirements for use: The equipment must be properly grounded (earthed). The input voltage must match the charger requirements. The battery voltage must match the charger s capabilities. The battery capacity is within the charger s range. ELECTRICAL SAFETY Safety regulations and requirements must be observed. Safety devices installed on the electrical supply to the chargers must be of the proper type and rating. It is important to ensure that only fuses of the proper capacity be used, should they need to be replaced. This charger meets the Class 1 Electrical Safety requirements, and therefore needs to be properly grounded during installation. It must be connected to a power supply equipped with a ground cable, and the ground connection should be as short as possible. The equipment must be totally disconnected from all power sources (main supply and battery) before it can be opened for inspection or servicing. The battery can only be disconnected after the STOP/START button has been pushed. Access to the inside of the charger should be restricted to authorized maintenance personnel. Please consult a qualified factory representative about any problems or questions related to the installation of this unit. 2
3 LIMITS OF USE This charger is designed to be used in a sheltered area. It is designed exclusively to recharge lead batteries in an industrial environment. PRODUCT RECYCLING - DESTRUCTION When this charger becomes obsolete, it can be recycled or destroyed by authorized facilities. Local regulations will prevail and must be followed. MODIFICATIONS AND IMPROVEMENTS EnerSys reserves the right, at any time, to modify or improve its products, without any obligation to update this product or this manual accordingly. RECEIVING - STORAGE Upon receipt, please inspect visually the exterior of the charger for any physical damage. If necessary, proceed within 24 hours with the usual claims procedure with the transport company. If the charger is to be stored before use, it should remain in the original packaging, carefully closed. Store in a clean, dry area at a moderate temperature (0 C to +40 C). If the equipment is stored at a temperature below 15 C, it must be gradually (24 hours) restored to operating temperature before use, to prevent the risk of condensation that could cause electrical faults and short-circuits. SPARE PARTS Please supply the unit s serial number, indicated on the information plate when ordering any spare parts. INFORMATION PLATE Located on either side of the charger. GLOSSARY Mixing enables faster charging of the battery and eliminates the differences in density by homogenizing the electrolyte throughout the cells. The ionic profile doesn t require weekly equalisation charge. Gel battery profile The procedure for charging sealed, maintenance-free batteries has been optimised to ensure that the particular requirements necessary for recharging are observed. The main advantages of these batteries are that there is no necessity to add water, thus reducing maintenance costs, and no necessity for special charging rooms (subject to local regulations) with ventilation and water demineralisation units. Water Less /Water Less 20 battery profile The charging procedure for Water Less batteries has been optimised in order to provide more flexibility and more time due to longer topping up intervals. Pneumatic battery profile PzM profile (Water Less) - 65 cycles WL20 profile (Water Less 20) cycles This type of battery is fitted with an air injection circuit allowing electrolyte circulation. The electrolyte circulation system reduces the charging time and the water consumption. EC DECLARATION OF CONFORMITY EnerSys hereby declares that the chargers in the Life IQ range covered by this declaration conform to: Directive 2006/95/EC (Low Voltage Directive) : EN Directive 2004/108/EC (ElectroMagnetic Compatibility) : EN , EN : Immunity and emissions limits for industrial electronics (class A- Industrial Environments) Directive 2002/95/EC (RoHS) Charger Features The EnerSys chargers are managed by a microprocessor. The microprocessor can calculate the battery capacity and automatically sets the appropriate charging profile. This allows the charger to work over a wide range of battery capacities. The control of the charging factor is absolute on all battery types. The Life IQ TM chargers adapt to battery capacity and depth of discharge. Charge factor Charge factor is the quantity of Ampere Hours returned to the battery during the charge cycle versus the amount removed during the last discharge. Refresh Charge A refresh charge maintains the battery at the optimum level as long as it is connected to the charger. Desulphation charge A desulphation charge is done prior to normal charging, and this charge restores the specific gravity of over-discharged or under-utilised batteries. Equalisation charge Done after the normal charge, a balancing charge that equalises the cell voltages and specific gravity of all cells in the battery. Wi-IQ This device, permanently installed on the battery, wirelessly transmits battery parameters to the charger in order to optimise the charge and to manage the charge and discharge data. Communicated parameters are: Temperature, battery capacity, warnings (water level, voltage balance), voltage, charging status The Wi-IQ also transmits data of the battery temperature during the charging process and will possibly stop the charge if the temperature is too high. Charging profile Defines the profile of the current applied to the battery during charging in relation to available time. Diverse charging profiles can be selected. The charger adapts to the battery based on capacity and state of charge and age in order to maximize overall battery life. The control of the overcharge factor, whatever the battery depth of discharge, provides a reduction in water consumption (except on VRLA batteries) and energy consumption. Ionic profile Also called Ionic Mixing this profile consists of applying short current pulses to the battery, thus provoking gassing in the active material to diffuse the sulphuric acid from the plates. This introduction of Ionic 3
4 DESCRIPTION COLOUR FUNCTION INTRODUCTION The Life IQ TM range of chargers is designed to recharge 24V, 36 V, 48 V or 80 V batteries, depending on the version supplied, from a singlephase or 3-phase main supply. The microprocessor-controlled unit automatically recognises the battery (voltage, capacity, charge level, etc.) and very effectively analyses its condition for optimum handling. Several charging profiles are available (vented lead/acid batteries, VRLA batteries (Hawker XFC TM ), gel batteries or Water Less batteries) depending on the configuration selected by the user. The capability for desulphation, equalisation and refresh charging is also included. FEATURES Dark blue Light blue Light blue Green Red Green Orange Orange Waiting status until battery connected Battery on charge Alternating, on charge indicating a defect pump or overdischarge or thermal fault Battery charged Charger faults DF1, DF2, DF3, TH Alternating, battery charged with defect pump or overdischarge The Life IQ chargers are: fitted as standard with: A wide LCD display with a five colour backlight indicating the status of the charger (Waiting, On charge, Fault, Battery charged) Wireless communication with the battery controller, Wi-IQ. This communication allows optimisation of the charge and automatic adjustment of the charger to the battery according to temperature, capacity and technology (vented, VRLA ). Communication occurs during the charge to analyse the battery temperature and compen sate for any loss in the output cables. A real time clock allows the management of charging at a precise time of day (for example, to use off-peak electricity tariffs), for equalising periods (for example: the user can configure an equalisation charge once or several times a week as required). Anti arcing system for safe disconnection during the charge. A USB interface enables the connection of a USB stick to download all data stored in the charger. optionally fitted with: Ethernet interface for remote management of the charger. EXTERNAL COMPONENTS Presented below: Functions of keys The keys offer the following general functions: Key GREEN/RED Function Navigation in the menu. Start/End of list (Press 2 seconds) The central button is equipped with a two-coloured LED Green/Red (Green: charger is waiting, Red charger operating) Stop or Start of charge Selection of active menu or validation of value stored Cancel the value stored (Press 2 seconds) Start an equalisation charge. Access to a sub-menu. Single phase model 3 phases model Access to the menus (press 3 seconds) Close the window Ref. Function 1. Ventilation louvres. 2. Display and control panel 3. AC input cable. 4. Battery cable. 5. Wall mounting frame. 6. Case retaining screw. 7. Navigation button Stop/Start button of the charger 8. USB 9. Option connector (Electro-valve, BSI, Ethernet ). Figure 1: Principal components of the charger. CONTROL PANEL Incorporates the Display and the Control Panel. See Chapters The Menus and Using the charger to get more detailed information. LCD Display The display is fitted with 5 different colours indicating the status of the charger: 4
5 THE MENUS The menus provide access to the following functions: Last 200 charging cycles (Memorisations menu). Viewing of faults, alarms, etc. (Status menu). Download of data stored in the charger via the USB storage memory. Charger configuration (Configuration menu). Setting of date, language and others (Parameters menu). Management of password (Password menu) Viewing basic information, type of charger (Information menu) ACCESS TO THE MENUS Functions of the keys To access the menu, press the key MEMORISED DATA for 3 seconds. Displays historical data from the last 200 charging cycles. The MEMO 1 refers to the latest record. Display an history Battery Auto/Manu capacity The charger can estimate the capacity of the connected battery (Auto) or the user can determine the capacity (Manu) via the Capacity menu. Capacity Determines the battery capacity for an optimised charge (Manu) Temperature Defines the battery temperature when the charge is started. This parameter adjusts the regulation voltages on the charging profile (values between 15 C and 65 C). Without Wi-IQ : defines the average operating battery temperature before the charge. With Wi-IQ: the battery operating temperature will be automatically defined. It is recommended to enter the observed average temperature, especially in cold areas. The battery temperature will be analysed during the charge; if it increases too much, the charger will stop to prevent any possible damage. High temperature Defines the safety limit in high temperatures. Without Wi-IQ: not used. With Wi-IQ: If the battery temperature, during the charge, reaches the programmed limit, the charger will stop the charge and wait until the temperature decreases. Charge Proceed as follows: 1. Select a record with or. 2. View the first screen by pressing. 3. View the successive lines by pressing. 4. Return to previous screen by pressing. STATUS This menu displays the charger s internal counters (number of normal charges, faults by type, etc.) Information displayed Reset information of this screen is done via the Configuration menu. Indication EGAL TH Information Number of complete charges. Number of incomplete charges. Number of automatic equalisation charges carried out by the charger. Number of temperature faults*. DF1, etc. Number of faults an types 1, 2, 3, 4, 5 or fault pump*. (*): see Fault codes USB This menu provides access to the USB function. The charger can store charging data in a USB memory. Record Memo Enables the storage of charge Memorisations and the Status data. The file, in CSV format (useable with Memoreport PC or Excel), will be stored in the USB stick under the name: MDDDHHMM.CSV with M : for Memorization DDD : Day of the year HH : Hour of file creation MM : Minute of file creation Eject For safe removal of the USB stick without damaging the data file. CONFIGURATION This menu allows to configure the charger. 006 Profile For selecting the right charging profile for the battery: ionic, gel, pneumatic, PzM (Water Less ) WL20 (Water Less 20), Hawker XFC TM With Wi-IQ: the selection of the profile will be automatic and the charger will recharge the battery with the appropriate profile whatever profile has been selected. AutoStart Default is ON, so the charge will start as soon the battery is connected to the charger. If Autostart is OFF, the charge will start only if the central button is pressed. Delayed start Defines: Either the charging start deadline Or the charging start hour. This delay enables the charger to be used during off-peak when the electricity is at lower tariffs. Note: the charger doesn t manage the summer/winter time changes. Conditional charge The charger will only commence the charge if the battery has reached the limit of depth of discharge of more than x%. For example if the user wants to charge the battery only if it is discharged more than 30%, the parameter 30 has to be entered in the conditional charge. The 0 value disables the function. Floating voltage Setting a floating voltage at the end of charge to compensate eventual consumption by the truck (AGV type). The parameter voltage determines the floating voltage at the end of the charge. The parameter Current defines the average current consumed by the truck electronics (crucial for currents at the end of charge). Maximum current This manually decreases the maximum output current of the charger. Equalisation These parameters are not valid for GEL and Hawker XFC TM batteries. Manu Current This defines the equalisation or desulphation current for a manual start. Time Sets the equalisation time from 1 hr to 48 hrs Delayed start (delay) Sets the delay between the normal charge and the equalisation charge from 0 hr to 23 hrs. Frequency Selects one or several periods for carrying out the equalisation charge. The user can select one or several days per week. Refresh Default is ON, (only for the IONIC profile) the refresh charge after the main charge maintains the battery in good condition by adding some pulse after the main charge. If the refresh is OFF, the refresh charge is disabled, but the equalization charge is still operating as defined on the previous menu. 5
6 Cable Length Selects the length of battery-charger DC cable from 1 m to 11 m. Section Defines the battery-charger DC cable cross-section. Select one section over the list of values (10, 16, 25, 35, 50, 70, 95 or 120 mm²). Network (Option) Sets the protocol and configuration for the connection of the charger to a network, type Ethernet or series. Option Options test Carries out a test of correct functionality of the options - managing the pump, electro-valve and remote display green/red during 30 seconds. Electrovalve time Defines the opening time (between 15 and 300 seconds ionic profile pneumatic, PzM (Water Less ) WL20 (Water Less 20) of the electro-valve for the automatic water refilling of the batteries. Reset Memo/status To reset the memorizations and status recorded by the charger. USING THE CHARGER UNPACKING The charger is delivered with the following: 2m AC mains cable. 3m DC battery cable. This technical manual. MECHANICAL INSTALLATION The charger must be mounted in a vertical position. For wall mounted chargers, the bottom of the charger must be at least 0.60 m from the floor and/or the charger below and the top of the unit at least 1.0 m from the ceiling. The minimum distance between two adjacent chargers must be 0.30 m. See paragraph Recommendations and avoid areas where the chargers may be splashed with water, or saline environments. The charger is held by 4 x M6 or M10 screws suitable for the type of support. The drilling pattern is depending on the charger model. See illustration below. Standard charger model 2 - Fixing L x H: 120 x 470 mm PARAMETERS Date/Time Sets date and time of the charger. The charger doesn t manage summer/winter time changes. Language Selects the language displayed in the menus. Region Selects the format for date, metric/imperial units for temperature and length. Contrast Modifies the display contrast level. Change Password Changes the password. PASSWORD Manages a password to limit access to charger menu.. INFORMATION Charger model 2 with optional pump - Fixing L x H: 304 x 355 mm Gives information on the software version, memory and time clock. 6
7 Standard charger model D - Fixing L x H: 470 x 350 mm Standard charger model E with optional pump - Fixing L x H: 470 x 350 mm Standard charger model D with optional pump - Fixing L x H: 470 x 350 mm ELECTRICAL CONNECTIONS Single phase and 3-phase input Connection to the mains supply will be 230V AC single phase or 400V AC 3-phase and must be connected using a suitable plug and adequately sized circuit breaker (not included). Current requirements in Amps are indicated on the charger information plate. Battery output It is essential to ensure correct polarity. However, reversed polarity will result in blowing the output fuse, inability to charge and the fault code DF2 to be displayed. See Fault Codes. Connection to the battery should be done using the cables supplied: RED cable: battery POSITIVE. BLACK cable: battery NEGATIVE. Standard charger model E - Fixing L x H: 470 x 350 mm 7
8 FACTORY SETUP The charger is delivered with a factory setup as follows: Profile: Output DC cable length: Configuration: Automatic equalisation: Delayed start enabled: As ordered 3 m As ordered No No If no modifications are required, go directly to the section: Charging the battery. If changes are required, go to the Configuration section. CHARGING THE BATTERY It is now assumed that the charger has been set up as per the Configuration section. Charging can only begin with a battery of the appropriate type, capacity and voltage connected to the charger. Off-charge display With the charger in waiting mode, the display shows information concerning the charger (top and bottom lines): 1. Charger type (Battery voltage + current). 2. Last selected charging profile. 3. Software version. 4. Waiting indication. 5. Date and time of the charge. 6. Set up battery operating temperature. Ref. Without Wi-IQ With Wi-IQ 1. Charger status (CHARGE, AVAIL, DEFAULT, EQUAL..), possible pump fault or DF4. 2. Alternating display of battery voltage, voltage per cell, Ah restored, charging time, remaining charging time, percentage of battery charge. 3. Set up operating battery T C, Battery temperature and and battery capacity if manual capacity given by the Wi-IQ mode set. (*). 4. Charging current 5. Programmed charging profile. Detected charging profile (*). 6. Various information can be displayed: equalisation symbol required at the end of charge, USB connection symbol, Wi-IQ link symbol, possibly battery default DF4. 7. Empty line. Alternating, detected serial number, as information is received and alarms if present. See Fault codes. Alternating battery temperature/capacity if the manu capacity mode is selected. WAIT 012 (*) as information is received. As soon as the countdown time has elapsed, the display shows the information relative to the charge. 010 To induce the start of the charge if the delayed charge has been programmed: 1. Connect the battery Delayed start If the charger was programmed for a delayed start (Configuration menu/delayed start), charging will begin following that delay. or at the specified time. The display shows the time remaining before the programmed charging starts. Starting a desulphation cycle before charging Desulphation of a vented battery is started manually, in this case the charger will consider the configuration in the menu Equalisation with the current and time set up in the charger menu. To start the desulphation charge, please proceed as follows. 1. Connect the battery 2. Press the central button to stop the charger. 3. Press and hold the button. 4. Press the central button to start the charger. Release. The standard charging cycle will have to be started manually after the desulphation cycle is completed. Initiating the equalisation charge after a standard charge An equalisation charge can be programmed at the end of charge when the user presses the button during the standard charge or when the battery is available. The equalisation symbol appears on the top, left side of the display. The equalisation current is defined by the charger. Starting the charge 1. If Autostart = On (default ON), the charge starts automatically when the battery is connected to the charger. To stop the charge, press the central button. If Autostart = OFF the charge will start only if the central button is pressed. To stop the charge, press the central button. The displays shows information relative to the connected battery and counts down the time remaining until the effective charge begins. 2. Press the central button to stop the charger. 3. Press and hold the central button for 3 seconds. Release. Defaults DF1, DF2, DF3 and TH inhibit the charge. Refer to section Fault codes. End of charge without equalisation 1. The backlight of the screen becomes green at the end of a correct charge. And the indication AVAIL is displayed. Possible alternating display between DF5 default and pump default and DF4 (ref.1). The displays shows alternately: (ref. 2): charging time achieved. number of Ah restored. Refer to sections Memorisations or Status for detailed information relevant to the end of charge. If the battery remains connected, and in order to maintain it in a fully charged condition, refresh charges followed by equalisation charges will be automatically initiated according to the battery technology. 2. If an equalisation charge has been programmed (vented battery), it will start automatically. Alternatively, an equalisation charge can be triggered manually; go to section End of charge with equalisation. 3. Press the central button or disconnect the battery that is now ready for use. End of charge with equalisation Equalisation only applies to vented batteries. Start can be manual or automatic. Manual start 1. At the end of charge (green lighted display on), press the key. The start of the equalisation charge is indicated by the message EQUAL. During the equalisation charge, the charger displays the current (ref 4) and alternating, the battery voltage, voltage per cell, remaining time (ref 2). 2. The battery will be available as soon as the screen becomes green. 8
9 Automatic start If the equalisation charge has been programmed (Configuration/Equalisation menu), the equalisation charge is initiated automatically. If the battery remains connected, and in order to maintain it in a fully charged condition, refresh charges followed by an equalisation charge will be automatically initiated according to the battery technology. Similar indications to those displayed in manual start (see above) are displayed. DISPLAY OF HISTORICAL DATA PER CHARGE For viewing and resetting stored information, please refer to section Memorisations. CHARGER HISTORICAL DATA For viewing and resetting the charger history, please refer to section Status. MESSAGES AND FAULT CODES TEMP* Critical battery Wait until the battery temperature. temperature cools down, check the battery state (water, profile) Verify the set up of temperature in the menu Configuration- Battery-High temperature. Control the temperature sensor of the Wi-IQ. DEF EEP* Memory/Charger menu. Change the main board DEF MENU* DEF CFG* Error in configuration or Check the input fuses and the 1 phase missing 3 phases, if OK, enter the password, go into the configuration menu, select charge menu, select charger list and select the right configuration on the list. IQ SCAN Look for present Wi-IQ Fault Cause Solution IQ LINK Set the link Wi-IQ-Charger DF1* Charger problem. DF1 appears when the charger is not able to supply its output current. Follow the breakdown procedure for the charger with control of the IGBT, diode, mains voltage DF2* Output default. Check the correct connection of the battery (reversed polarity cables) and the output fuse. DF3* Wrong battery. Too high or too low battery voltage. Battery voltage must be between 1.6V and 2.4V per cell. Use correct charger for the battery. DF4 Battery discharged more Charge continues. than 80% of its capacity. DF5 Battery requires DF5 appears when the charging inspection. profile has been achieved with a fault condition, that can be a current increase in regulation phase demonstrating a battery heating or badly programmed regulation voltage, or the charging time is too long and has exceeded the safety limit. Low electrolyte level Default of balance voltage detected by the Wi-IQ Battery water topping up or ensure that the Wi-IQ is properly adjusted and installed (see Wi-IQ mounting instructions) Check each battery cell during discharge. Check the Wi-IQ is correctly set-up (see Wi-IQ instructions of mounting). Battery temperature Verify the battery electrolyte T too high. level or the correct set up of the charger. Preventive maintenance indicator. Check the temperature sensor of the Wi-IQ. Consult a qualified factory representative to conduct preventive maintenance operation. (*): blocking fault preventing charging from continuing. Check charging parameters: profile, temperature, capacity, cables. Check the battery (defective cells, high temperature, water level..). DF PUMP Fault in the air circuit Check the proper operation of of the electrolyte the pump via the menu circulation system. Option-Option test. Check the air circuit (pump, tubes). If this fault occurs, the charger will adapt the battery charging profile for a safe, optimised charge. TH* Thermal problem in Verify the correct operation of charger resulting in the fans, check for too high charge interruption. ambient temperature, or whether there is poor natural ventilation to the charger. STOP* Critical battery electrolyte Top up battery electrolyte level level in accordance with battery operating instructions. 9
10 Wherever you do business, EnerSys can support you with motive power energy. The Hawker branded battery range, matched chargers and systems provide trouble free perfor mance under the most demanding service conditions. Our strategically located manufacturing plants are efficient and responsive with a culture of continuous improvement and added value for our business partners. EnerSys has an enviable position in technology leader ship and with significant investment in research and development we intend to stay at the leading edge in product innovation. The recently developed energy solutions: Water Less 20 and Hawker XFC TM batteries, Lifetech and Lifespeed IQ TM HF chargers, have defined new benefits for our customers: faster recharge, more machine availability, lower operating and investment costs, reduced carbon footprint. Our team of development engineers is driven by the desire to build the best energy solutions and works closely with our customers and suppliers to identify development opportunities. Our bias for rapid in no vation means we get new products to market fast. EnerSys's integrated sales and service network is dedicated to providing our customers with the best solutions and after-sales support for their business. Whether you require 1 battery or a complete fleet of batteries, chargers, a battery handling system and a state of the art fleet management system, you can count on us. EnerSys is the world's largest industrial battery manufacturer and we are dedicated to being the best. European Headquarters: EnerSys EMEA EH Europe GmbH Löwenstrasse Zürich Switzerland Phone: Fax: Local contact: Enersys Ltd Oak Court Clifton Business Park Wynne Avenue Swinton Manchester M27 8FF Phone: Fax: Please refer to the website address for details of your nearest EnerSys office: All rights reserved. All trademarks and logos are the property of or licensed to EnerSys and its affiliates unless otherwise noted Subject to revisions without prior notice
Technical data Smart chargers Hawker Lifetech
Technical data Smart chargers Hawker Lifetech Lifetech chargers Matching table of capacity and recharge time Recharge time in hours for a 80 % discharged battery, discharged battery at a electrolyte temperature
Small Traction powerbloc powerbloc dry Hawker XFC TM
Small Traction powerbloc powerbloc dry Hawker XFC TM Bigger power for small traction Powerbloc Powerbloc dry Hawker XFC TM Powerbloc, powerbloc dry and Hawker XFC are ranges of bloc batteries for all applications
HAWKER MODULAR CHARGERS KEEP ON GOING! EVEN WHEN PART OF THE TEAM IS MISSING...
HAWKER MODULAR CHARGERS KEEP ON GOING! EVEN WHEN PART OF THE TEAM IS MISSING... MODULAR: SETTING A NEW STANDARD PEAK PERFORMANCE AND RELIABILITY The plug and play modules are managed by the charger s algorithm.
www.ringautomotive.co.uk Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A
SmartChargePro7 RSCPR7-12v, 7A SmartChargePro10 RSCPR10-12v, 10A SmartChargePro15 RSCPR15-12v, 15A SmartChargePro25 RSCPR25-12v, 2 / 6 / 12 / 25A SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A SmartChargePro50
MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.
MX MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest
BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000
Manual EN BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000 Contents EN 1.Important safety instructions... 2 2. Installation... 2 3.Product
HAWKER MODULAR CHARGERS KEEP ON GOING! EVEN WHEN PART OF THE TEAM IS MISSING...
HAWKER MODULAR CHARGERS KEEP ON GOING! EVEN WHEN PART OF THE TEAM IS MISSING... Service manual The modular range is based on the modular concept made of universal power bricks allocated into different
1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.
MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest
EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY
MODE 24V/ MANUAL MXT 14 CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents
MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING
MODE 12V/ MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the
MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.
MANUAL CONGRATULATIONS on the purchase of your new professional switch mode battery charger and tester. This charger and tester is included in a series of professional chargers from CTEK Sweden AB and
MANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel
MANUAL CONGRATULATIONS on the purchase of your new CTEK professional battery management unit. This unit is part of a range of professional battery chargers from CTEK SWEDEN AB. It represents the latest
Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS
+ Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger
Digital echo-charge Owner s Manual Xantrex Digital echo-charge Battery Charger Thank you for purchasing a Xantrex Digital echo-charge. Xantrex Technology Inc. takes pride in manufacturing quality products
SPY-BATT Battery Tutor Device Installation Manual Rev. 1.1-07/04/2016
SPY-BATT Battery Tutor Device Installation Manual Rev. 1.1-07/04/2016 1. GENERAL DESCRIPTION The SPY-BATT is a device that allows to monitor the state of your battery. The SPY-BATT stores over time the
Solar Controller / Battery Charger User s Manual
Solar Controller / Battery Charger User s Manual 1 Congratulations! You have made an excellent choice by purchasing this high quality KORR PWM solar controller which has been manufactured to the highest
PD 100A. Printing data system
PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep
2 Installation Explanation
Intelligent Solar Charge Controller Solar30 User s Manual Please read this instruction carefully before using it. SOLAR30 12V/24V AUTO WORK 1 Product introduction This controller is a kind of intelligent
MXS 3. MANUAL FULLY CHARGED PULSE, MAINTENANCE CHARGING EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT CHARGE CABLE ERROR LAMP MODE- BUTTON
MODE 12V/ MXS 3. MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWED AB and represents
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
SNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
SOLAR POWER - THE NEW WAY TO RV!
IMPORTANT! - YOU'RE SOLAR READY SOLAR POWER - THE NEW WAY TO RV! Your RV is PRE-WIRED for SOLAR POWER! Benefits of Solar Zamp Solar Portable Solar Kit Maximize Battery Life Electrical Independence Green,
MULTI XS 4003 Battery charger
MULTI XS 4003 Battery charger For lead-acid batteries 1.2 140Ah FI NO DK SE NL QUICK GUIDE EN DE IT ES FR Model 1035 User s Manual and a guide to professional battery charging for starter/deep cycle batteries.
Industrial Batteries / Motive Power. 2100 Chargers 2100.NET.»For improved efficiency and durability«
Industrial Batteries / Motive Power 2100 Chargers 2100.NET»For improved efficiency and durability« Motive Power > 2100 Product overview 2100 product range Energy Efficiency and Economy reduce overall operating
LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL 16350 TYPE 12/24EL40-10ET
LESTRONIC DV AUTOMATIC 12 OR 2 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL 16350 TYPE 12/2EL0-10ET PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS For correct operation of the equipment,
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
LITHIUM BALANCE CHARGER
LITHIUM BALANCE CHARGER A Microprocessor controlled, high-performance charger for NiCd/NiMH/LiPo/Pb batteries with an integral individual voltage balancer (LiPo only) Operating Manual Please read this
13 Watt PORTABLE SOLAR POWER KIT
3 Watt PORTABLE SOLAR POWER KIT User s Manual Thank you for purchasing a Sunforce Portable Solar Power Kit. Please read these instructions carefully and thoroughly before using the product. Your new Portable
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
B/S/H/ Error codes and service programmes PH
1 ERROR CODES AND APPLIANCE MESSAGES... 3 1.1 Complete overview of all error codes (in order)... 3 Automatic switch-off... 3 Display is dark and any individual LEDs are lit... 3 E 005... 3 E 011... 3 E
MULTI XS 3600. Battery charger. For lead-acid batteries 1,2-120Ah
MULTI XS 3600 Battery charger For lead-acid batteries 1,2-120Ah User s Manual and a guide to professional battery charging For Starter/Deep Cycle batteries EN INTRODUCTION Congratulations on your purchase
Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation
Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation BATTERY CHARGING GUIDELINES FOR GLOBAL/DAVIDSON TUBULAR PLATE BATTERIES Introduction Your Global/Davidson
12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual
12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual This 30Amp charge controller is designed to protect your 12Volt Lead-acid or Gel-cell battery from being overcharge by solar
Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps
Solar Home System User Manual AEHSHS0110W2L Solar Home System 2 Lamps All rights reserved Specifications subject to change without prior notice 2 Dear Customer, Thank you for purchasing Schneider Electric
Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.
*00151* FEATURES Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate. Silicon diodes with inherent surge protection operated at a conservative
Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
Back-UPS 650 VA 120 V with AVR (BX650CI-LM)
Back-UPS 650 VA 120 V with AVR (BX650CI-LM) Overview Do not install the unit in direct sunlight, in areas of excessive heat or humidity, or in contact with fluids ON/OFF button Battery connector Circuit
Manual. Solar Fountain Mobile Phone Charger
EN Manual Solar Fountain Mobile Phone Charger Copyrights 2008 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose.
OCSM Series. High Resolution Digital Crane Scale. User Guide
OCSM Series High Resolution Digital Crane Scale Content 1. Safety Guide... 1 2. Features... 1 3. Specifications... 2 4. Capacity... 3 5. Display & Keys... 3 Scale & Remote Keys... 3 Indicators... 4 Message...
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
How To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
ACHIEVING CHARGE QUALITY FOR LEAD ACID BATTERIES IN INDUSTRIAL MOTIVE APPLICATIONS
ACHIEVING CHARGE QUALITY FOR LEAD ACID BATTERIES IN INDUSTRIAL MOTIVE APPLICATIONS Delta-Q Technologies success as an industrial battery charger supplier to original equipment manufacturers (OEMs) has
Charge Regulator SCR 12 Marine
Charge Regulator SCR 12 Marine Manual Many thanks for purchasing a superwind product. The SCR 12 Marine is a charge regulator of highest quality and will perfectly and reliably charge your batteries for
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
Installation and Operation Back-UPS 1250, 1300, 1500
Installation and Operation Back-UPS 1250, 1300, 1500 Inventory bu001a Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with
3000W Power Inverter
3000W Power Inverter OWNER S MANUAL Model number-4573000 TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE
User Manual for CH-PFC76810
AA Portable Power Corp www.batteryspace.com, Email: [email protected] User Manual for CH-PFC76810 1. Overview The CH-PFC76810 charger is suitable for charging lithium ion battery packs such as those
BATTERY CHARGING GUIDELINES FOR 6-VOLT DEEP CYCLE BATTERIES
BATTERY CHARGING GUIDELINES FOR 6-VOLT DEEP CYCLE BATTERIES Introduction Your 6-volt deep cycle battery set has been specially formulated for long cycle life and has particular voltage and specific gravity
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
POWER TO GET THE JOB DONE
52720 1.5 AMP SLOW 12 VOLT BATTERY CHARGER OWNER S MANUAL KEEPS BATTERIES FULLY CHARGED IN STORAGE Automatic over-charging protection Short circuit protection Reverse hook-up protection Overheat protection
Sigma Control PC INSIDE. 97 psi 187 F R on load
Sigma Control PC INSIDE 97 psi 187 F R on load Innovation Sigma Control with a PC inside At Kaeser, we pride ourselves on being the world s leading innovator in air system technology. Over twenty-five
CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/
CW-5000/ 5200 Contents Cautions ---------------------------------------------------------------- 3 Parts introduction --------------------------------------------------- 4 Installation ------------------------------------------------------------
UPS Network Interface. Quick InstallationGuide
UPS Network Interface Quick InstallationGuide Version 1.1 March 1999 COPYRIGHT Copyright 1999 RINGDALE UK Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed,
Installation guide H-5500-8554-03-A. HSI hardwired system interface
Installation guide H-5500-8554-03-A HSI hardwired system interface 2008-2011 Renishaw plc. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred to any
QFP910. Water detector. Building Technologies. CE1N2732en 2016-03-01. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
E E V R E - R S - O S L O A L R
Solar Eye User Manual Edition JIANGSU EVER-SOLAR NEW ENERGY CO., LTD. Revision History Date Edition Specification 17/08/2011 1.0 Create File 02/09/2011 1.1 Add Micro SD function description www.ever-solar.com
Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.
Data logger Installation and operating instructions SOREL Connect Read carefully before installation, commissioning and operation 1.1. - Specifications Description of data logger Electrical specifications:
Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V
Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V APC Smart-UPS, 670 Watts / 1000 VA,Input 230V / Output 230V, Interface Port DB-9 RS-232, SmartSlot, USB Includes: CD with software, Smart UPS signalling
GSM Alarm System User Manual
GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following
OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada
2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) OWNER S MANUAL 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada Tel: (604) 420-1585 Fax: (604) 420-1591 http:// www. statpower.com PROsine 2.5/3.0 ACS Panel
I4.35. Link 2000. Owner's Manual. AL Xantrex OWNERS MANUAL. Link 2000. Inverter Controller and Dual Battery Monitor. Link 2000. Control.
Link 2000 Control Invert Idle Mode Charger Pwr Share I4.35 Battery 1 Reset A hrs 2 Data Setup Volts Charged V Amps Charged % A hrs Batt Cap Time Function Equalize Status: AC In Charge Accept F l o a t
TROUBLESHOOTING GUIDE
TROUBLESHOOTING GUIDE LESTRONIC II BATTERY CHARGER FOR MOTIVE POWER BATTERIES PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS For correct operation of the equipment, it is important to read
ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
148 OLD CONCORD TURNPIKE, BARRINGTON NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:[email protected] www.seafrost.com ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
Quick start guide smart.power smart.power smart.power
Quick start guide Intended use: smart.power is a universal charging device for charging (in absence of other charging options) your mobile phone, your TEASI-navigation system or other devices with a 5V
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
Stereoscopic 3D Digital Theater System. Operator Manual (MI-2100)
Stereoscopic 3D Digital Theater System Operator Manual (MI-2100) -1- All information contained in or disclosed by this document is confidential and propriety to masterimage Co., Ltd. (hereinafter referred
D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.
SECTION 263354 STATIC UPS TESTING AND COMMISSIONING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes 1. System start-up services. 2. Battery charging. 3. Load bank testing. 4. Battery load testing. 5.
PSC POWER STAR LiFE TM
PSC POWER STAR LiFE TM Operation Manual Version 3.0 Copyright 2012 Professional Sound Corp 28085 Smyth Drive, Valencia, CA 91355 USA CE RoHS Printed in the U.S.A. Thank you for purchasing your new PSC
LCD5500Z / PKP-LCD v3.x Installation Instructions
LCD5500Z / PKP-LCD v3.x Installation Instructions TM Introduction The LCD5500Z / PKP-LCD keypad displays system status using an LCD screen. The keypad can be used on PowerSeries security systems with up
DAB+ / FM Tuner Model: TU-201
DAB+ / FM Tuner Model: TU-201 Instruction Manual www.pulse-audio.co.uk 1 Safety Information The lightning bolt within a triangle is intended to alert the user to the presence of dangerous voltage levels
Operation and Installation Manual
Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control
Communication bridge Xcom-MS User Manual
Communication bridge User Manual Copyright 2011 Studer Innotec SA - V1.0.1 Communication bridge : User Manual V1.0.1 Copyright 2011 Studer Innotec SA About the software This document applies to the software
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The
PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00
Standalone door control module PK-01 Firmware version 1.00 pk-01_en 06/12 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 [email protected] www.satel.eu WARNINGS Read carefully
TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser
FITTING AND OPERATING INSTRUCTIONS FOR DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM General information is given in the users instruction leaflet despatched with the appliance and/or on
User Manual HomeGrid 3000 Solar Generator
User Manual HomeGrid 3000 Solar Generator For more information and instruction videos visit: www.pointzeroenergy.com/learn/videos/ HomeGrid 3000 Solar Generator Congratulations on purchasing Point Zero
Installation and Operating Instructions (for chargers shown below)
Installation and Operating Instructions (for chargers shown below) For additional information please call our Technical Support Group 800.742.2740 PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard,
Constant Voltage Charger Selection for VRLA Batteries
TECHNICAL BULLETIN 41-2129 Constant Voltage Charger Selection for VRLA Batteries Please Note: The information in this technical bulletin was developed for C&D Dynasty 12 Volt VRLA products. While much
Nokia Bluetooth Headset BH-607. Issue 2. 1
Nokia Bluetooth Headset BH-607 2 3 1 4 5 6 7 8 9 11 10 Issue 2. 1 12 13 14 DECLARATION OF CONFORMITY Hereby, NOKIA CORPORATION declares that this BH-607 product is in compliance with the essential requirements
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.7) Version:3.0 ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2
PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: WWW.BRITEQ-LIGHTING.COM TABLE OF CONTENTS
STGE COO 48 Preliminary User Guide Official version will follow soon on: WWW.BITEQ-IGHTIG.COM TBE OF COTETS 1. Safety Instruction 2. Technical Specification 3. How To Set The Unit 4. How To Control The
FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7
FAQs Conserve package Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7 FAQs Gateway Can I have someone install my system for me? If you are concerned
Fire Alarm Control Panel. Family. Operating Manual
Fire Alarm Control Panel Family Operating Manual CONTENTS System Description AH-03312 System Characteristics... Fire Signal Receiving Board Description-4L... Fire Signal Receiving Board Description-8L...
SOLAR PV SYSTEM MAINTENANCE GUIDE
SOLAR PV SYSTEM MAINTENANCE GUIDE GUYANA HINTERLANDS STAND-ALONE SOLAR PV INSTALLATIONS IMPROVING HEALTH FACILITY INFRASTRUCTURE (IHFI) GUYANA CONTRACT NO. EPP-I-00-03-00008-00, TASK ORDER 07 APRIL 2013
SAGEM F@st TM 1201/1241 V2
SAGEM F@st TM 1201/1241 V2 Quick Installation Guide 253156400-A_GIR 1201 V2 STD-gb.i1 1 14/10/2008 16:59:35 Contents 1 contents of the pack...2 2 connecting YOUR MODEM...3 2.1 Connecting your router...3
Wireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
Powerware 5110 UPS User s manual
Powerware 5110 UPS 2005 Eaton Corporation All Rights Reserved The contents of this manual are the copyright of the publisher and may not be reproduced (even extracts) unless permission granted. Every care
IN-OUT Thermometer with Cable Free Sensor and Clock
IN-OUT Thermometer with Cable Free Sensor and Clock MODEL: RAR232 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RAR232 In-Out Thermometer with 433MHz cable free sensor and calendar
EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!
EPSOLAR LS0512R / LS0524R Solar Light Controller INSTRUCTION MANUAL Please read this manual carefully before using the product! LandStar LS0512R / LS0524R Solar Light Controller Nominal system voltage
Understand Hybrid Generator Battery Systems
Understand Hybrid Generator Battery Systems For off-grid applications powered by diesel generators, move to cyclic operation to save costs Telecommunications operators in Africa, India and other developing
User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com
Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com Document updates: Version Data Description V1.0 2015.05.25 Finish new document HVAC Controller User Manual INDEX 1. Overview...1
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
15 Digital Photo Frame Instructional Manual
15 Digital Photo Frame Instructional Manual aluratek.com mnl M10054 ADMPF315F Copyright 2011 Aluratek, Inc. All Rights Reserved. Table of Contents Frame Close-up... Remote Control Close-up... Package Contents...
BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault
WHOLESALE DIRECT INC. 5620 WEST 65TH STREET
Auto Pump V 200 100 0 100 Max Rating Vehicle mount compressor ensures truck air brake system is properly pressurized for immediate dispatch from station Pressure switch regulated operation automatically