Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide
|
|
|
- August Cameron
- 9 years ago
- Views:
Transcription
1 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide Sun Microsystems, Inc. Part No December 2008, Revision B Submit comments about this document at:
2 Copyright 2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun Microsystems, Inc. has intellectual property rights relating to technology embodied in the product that is described in this document. In particular, and without limitation, these intellectual property rights may include one or more of the U.S. patents listed at and one or more additional patents or pending patent applications in the U.S. and in other countries. This distribution may include materials developed by third parties. Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in the U.S. and in other countries, exclusively licensed through X/Open Company, Ltd. Sun, Sun Microsystems, the Sun logo, Java, Netra, Solaris, Sun Ray, Sun Fire Servers, Sun Fire X4100 Server, Sun Fire X4100 M2 Server, Sun Fire X4200 Server, Sun Fire X4100 M2 Server, SunVTS, the Java Coffee Cup logo, the Solaris logo, Sun and Java are trademarks or registered trademarks of Sun Microsystems, Inc., or its subsidiaries, in the U.S. and other countries. UNIX is a registered trademark in the United States and other countries, exclusively licensed through X/Open Company, Ltd. AMD Opteron AMD, Opteron, the AMD logo, the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro Devices. The OPEN LOOK and Sun? Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements. Use of any spare or replacement CPUs is limited to repair or one-for-one replacement of CPUs in products exported in compliance with U.S. export laws. Use of CPUs as product upgrades unless authorized by the U.S. Government is strictly prohibited. DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. Copyright 2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, Etats-Unis. Tous droits réservés. Sun Microsystems, Inc. détient les droits de propriété intellectuels relatifs à la technologie incorporée dans le produit qui est décrit dans ce document. En particulier, et ce sans limitation, ces droits de propriété intellectuelle peuvent inclure un ou plus des brevets américains listés à l adresse et un ou les brevets supplémentaires ou les applications de brevet en attente aux Etats - Unis et dans les autres pays. Cette distribution peut inclure des éléments développés par des tiers. Des parties de ce produit pourront être dérivées des systèmes Berkeley BSD licenciés par l Université de Californie. UNIX est une marque déposée aux Etats-Unis et dans d autres pays et licenciée exclusivement par X/Open Company, Ltd. Sun, Sun Microsystems, le logo Sun, Java, Netra, Solaris, Sun Ray, Sun Fire Servers, Sun Fire X4100 Server, Sun Fire X4100 M2 Server, Sun Fire X4200 Server, Sun Fire X4200 M2 Server, SunVTS, le logo Java Coffee Cup, le logo Solaris, Sun et Java sont des marques de fabrique ou des marques déposées de Sun Microsystems, Inc., ou ses filiales, aux Etats-Unis et dans d autres pays. UNIX est une marque enregistree aux Etats-Unis et dans d autres pays et licenciée exclusivement par X/Open Company Ltd. AMD Opteron est une marque déposée de Advanced Micro Devices, Inc. L interface d utilisation graphique OPEN LOOK et Sun(TM) a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sun reconnaît les efforts de pionniers de Xerox pour la recherche et le développement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique. Sun détient une license non exclusive de Xerox sur l interface d utilisation graphique Xerox, cette licence couvrant également les licenciés de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui, en outre, se conforment aux licences écrites de Sun. L utilisation de pieces detachees ou d unites centrales de remplacement est limitee aux reparations ou a l echange standard d unites centrales pour les produits exportes, conformement a la legislation americaine en matiere d exportation. Sauf autorisation par les autorites des Etats- Unis, l utilisation d unites centrales pour proceder a des mises a jour de produits est rigoureusement interdite. LA DOCUMENTATION EST FOURNIE "EN L ETAT" ET TOUTES AUTRES CONDITIONS, DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES, DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE, Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE, A L APTITUDE A UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFACON.
3 Contents Preface v 1. Setting Up the Server Hardware 1 Installation Overview 1 Installing the Server Into a Rack With Optional Slide Rails 2 Disassembling the Slide Rails Before Installation 3 Installing the Mounting Brackets Onto the Server 4 Attaching the Slide-Rail Assemblies to the Rack 5 Installing the Server Into the Slide Rail Assemblies 6 Installing the Cable Management Assembly 7 Attaching and Routing Cables 12 Verifying Operation of the Slide Rails and CMA 12 Installing Cables 13 Powering On and Off the Server 16 Applying Standby Power for Initial Service Processor Configuration 16 Powering On Main Power Mode 16 Shutting Down Main Power Mode Setting Up the Server Software 19 Introduction to the Integrated Lights Out Manager 19 iii
4 Connecting to the ILOM Service Processor 21 Connecting to ILOM Using a Serial Connection 21 Connecting to ILOM Using an Ethernet Connection 23 Configuring ILOM Ethernet Settings Using DHCP 23 Configuring ILOM Using Static Ethernet Settings 26 Setting Up Platform Operating System and Driver Software 28 Drivers for Option Cards Configuring the Preinstalled Solaris 10 Operating System 31 Before You Begin 31 Installation Worksheet 32 Selecting Your Console Output 35 Configuring the Preinstalled Solaris 10 Operating System 36 To Connect to the Server Using the Service Processor s IP Address 37 To Connect to the Server Using a Terminal Program 38 Solaris 10 User Documentation 39 Downloading Solaris 10 OS Software 39 Solaris 10 OS Training 39 Index 41 iv Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
5 Preface This guide contains procedures for installing the server in a rack, cabling, and powering on the server. It also contains procedures for connecting to the service processor administrator account. Links to documentation for configuring the preinstalled Solaris 10 software or for installing other supported operating systems are also included. Related Documentation For a description of the document set, see the Where To Find document that is packed with your system and also available at the product documentation site. Refer to the following URL, then navigate to your product: This site also contains translated versions of some of these documents in French, Simplified Chinese, Traditional Chinese, Korean, and Japanese. English documentation is revised more frequently and might be more up-to-date than the translated documentation. For all Sun documentation, refer to: For Solaris and other software documentation, refer to: v
6 Support and Training The Sun web site provides information about the following additional resources: Sun Function Support Training Warranty URL Product Updates For product updates that you can download for the Sun Fire X4100 or X4200 servers, please visit the following Web site: This site contains updates for firmware and drivers, as well as CD-ROM.iso images. Sun Welcomes Your Comments Sun is interested in improving its documentation and welcomes your comments and suggestions. You can submit your comments by going to: Please include the title and part number of your document with your feedback: Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide, vi Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
7 CHAPTER 1 Setting Up the Server Hardware This chapter contains the following topics: Installation Overview on page 1 Installing the Server Into a Rack With Optional Slide Rails on page 2 Installing Cables on page 13 Powering On and Off the Server on page 16 Note The information in this book applies to all Sun Fire X4100/X4100 M2 and X4200/X4200 M2 servers, unless otherwise noted. Installation Overview After unpacking your server, perform the following tasks, which are described in the documentation as indicated: 1. If desired, install the server into a rack using orderable slide-rails. See Installing the Server Into a Rack With Optional Slide Rails on page Connect all cables, peripherals, and power cords. See Installing Cables on page 13 for an illustration of the server s back panel connector ports. 3. Power on and boot the server as described in Powering On and Off the Server on page Connect to the service processor as described in Setting Up the Server Software on page 19. 1
8 5. Configure the preinstalled Solaris operating system or install a supported operating system of your choice. For details, refer to one of the following: Configuring the Preinstalled Solaris 10 Operating System on page 36. Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Operating System Installation Guide, Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Windows Operating System Installation Guide, Customize your server as needed. For details, refer to the System Management section of the online information system or the Integrated Lights-Out Manager Administration Guide, Installing the Server Into a Rack With Optional Slide Rails To install your server in a four-post rack using the orderable slide-rail option, follow these procedures. These slide rails are compatible with a wide range of equipment racks that meet the following standards: Four-post structure (mounting at both front and rear). Two-post racks are not compatible. Rack horizontal opening and unit vertical pitch conforming to ANSI/EIA 310-D-1992 or IEC standards. Distance between front and rear mounting planes between 610 mm and 915 mm (24 inches to 36 inches). Clearance depth (to front cabinet door) in front of front rack mounting plane at least 25.4 mm (1 inch). Clearance depth (to rear cabinet door) behind front rack mounting plane at least 800 mm (31.5 inches) or 700 mm (27.5 inches) without cable management arm. Clearance width (between structural supports and cable troughs) between front and rear mounting planes at least 456 mm (18 inches). Note Although the Sun Fire X4100/X4100 M2 server is pictured in the illustrations in this section, these procedures also apply to the Sun Fire X4200/X4200 M2 server. Caution Always load equipment into a rack from the bottom up so that the rack does not become top-heavy and tip over. Deploy your rack s anti-tilt bar to prevent the rack from tipping during equipment installation. 2 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
9 Disassembling the Slide Rails Before Installation Use this procedure to remove the mounting brackets from the slide-rail assemblies. 1. Unpack the slide-rails. 2. Locate the slide-rail lock at the front of one of the slide-rail assemblies, as shown in FIGURE Squeeze and hold the tabs at the top and bottom of the lock while you pull the mounting bracket out of the slide-rail assembly, until it reaches the stop. See FIGURE Pull the mounting bracket release button toward the front of the mounting bracket, as shown in FIGURE 1-1, and simultaneously withdraw the mounting bracket from the slide-rail assembly. 5. Repeat the procedure for the remaining slide rail assembly. FIGURE 1-1 Disassembling the Slide-Rail Before Installation Mounting bracket release button Slide-rail lock Chapter 1 Setting Up the Server Hardware 3
10 Installing the Mounting Brackets Onto the Server Use this procedure to install the mounting brackets onto the sides of the server. 1. Position a mounting bracket against the chassis so that the slide-rail lock is at the server front, and the three keyed openings on the mounting bracket are aligned with the three locating pins on the side of the chassis. See FIGURE 1-2. FIGURE 1-2 Aligning the Mounting Bracket With the Server Chassis Chassis front Mounting-bracket clip Mounting bracket Slide-rail lock 2. With the heads of the three chassis locating pins protruding though the three keyed openings in the mounting bracket, pull the mounting bracket toward the front of the chassis until the mounting-bracket clip locks into place with an audible click. See FIGURE Verify that all three locating pins are trapped in the keyed openings and that the rear locating pin has engaged the mounting-bracket clip. See FIGURE Repeat the procedure to install the remaining mounting bracket on the other side of the server. 4 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
11 Attaching the Slide-Rail Assemblies to the Rack Use this procedure to install the slide-rail assemblies to the rack. 1. Position a slide-rail assembly in your rack so that the brackets at each end of the slide-rail assembly are on the outside of the front and rear rack posts. See FIGURE Attach the slide-rail assembly to the rack posts. The method used to attach the slide-rails varies depending on the type of rack: If your rack has threaded mounting holes in the rack posts, first determine whether the threads are metric or standard, then insert the correct mounting screws through the slide-rail brackets and into the threaded holes. If your rack does not have threaded mounting holes, insert the mounting screws through both the slide-rail brackets and rack posts, then secure them with the caged nuts. FIGURE 1-3 Slide-Rail Assembly Mounting to Rack Post Rack post Slide-rail assembly with mounting bracket removed Slide-rail assembly bracket on outside of rack post 3. Repeat the procedure for the remaining slide rail assembly. Chapter 1 Setting Up the Server Hardware 5
12 Installing the Server Into the Slide Rail Assemblies Use this procedure to install the server chassis, with mounting brackets, into the slide-rail assemblies that are mounted to the rack. Caution This procedure requires a minimum of two people because of the weight of the server. Attempting this procedure alone could result in equipment damage or personal injury. 1. Push the slide-rails into the slide-rail assemblies as far as possible. 2. Raise the server so that the rear ends of the mounting brackets are aligned with the slide-rail assemblies that are mounted in the equipment rack. See FIGURE Insert the mounting brackets into the slide-rails, then push the server into the rack until the mounting brackets encounter the slide-rail stops (approximately 12 inches or 30 cm). FIGURE 1-4 Inserting the Server With Mounting Brackets Into the Slide-Rails Slide-rail assembly mounted on rack post Mounting bracket inserted into slide-rail Slide-rail release button Slide-rail locks 6 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
13 4. Simultaneously pull and hold the slide rail release buttons on each mounting bracket while you push the server into the rack. See FIGURE 1-4. Continue pushing until the slide-rail locks on the front of the mounting brackets engage the slide-rail assemblies. Caution Verify that the server is securely mounted in the rack and that the sliderails locks are engaged with the mounting brackets before continuing. Installing the Cable Management Assembly Use this procedure to install an optional cable management assembly (CMA). 1. Unpack the CMA parts. 2. Take the CMA to the rear of the equipment rack and ensure that you have adequate room to work around the rear of the server. Note References to left or right in this procedure assume that you are facing the rear of the equipment rack. 3. Locate the CMA rail extension and insert it into the left slide-rail until the extension locks into place with an audible click. See FIGURE 1-5. Chapter 1 Setting Up the Server Hardware 7
14 FIGURE 1-5 Inserting the CMA Rail Extension Into the Rear of the Left Slide-Rail CMA rail extension Left slide-rail 4. Verify that the CMA rail extension engages the slide-rail, as shown in FIGURE Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
15 FIGURE 1-6 Detail of CMA Rail Extension Inserted Into the Left Slide-Rail CMA rail extension Left slide-rail Note Support the CMA in the remaining installation steps. Do not allow the assembly to hang by its own weight until it is secured by all three attachment points. 5. Insert the CMA s mounting bracket connector into the right slide-rail until the connector locks into place with an audible click. See FIGURE 1-7. Chapter 1 Setting Up the Server Hardware 9
16 FIGURE 1-7 Inserting the CMA Mounting Bracket Into the Rear of the Right Slide-Rail Right slide-rail CMA mounting bracket 6. Insert the right CMA slide-rail connector into the right slide-rail assembly until the connector locks into place with an audible click. See FIGURE 1-8. FIGURE 1-8 Inserting CMA Slide-Rail Connector Into Rear of Right Slide-Rail Assembly Right sliderail assembly CMA slide-rail connector 10 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
17 7. Insert the remaining CMA arm connector into the plastic cutout on the CMA rail extension, which you installed to the left slide-rail in Step 3. See FIGURE 1-9. FIGURE 1-9 Connecting the CMA Arm to Rail Extension Connector CMA extension arm (on left slide-rail) Tab CMA arm connector 8. Gently press the tab in the direction indicated in FIGURE 1-9 to open the cutout enough to insert the connector. Once you pass the connector through the cutout, release the tab to lock the connector in place. 9. Position the cable hangers in the appropriate mounting holes in the CMA and snap them into place. See FIGURE Chapter 1 Setting Up the Server Hardware 11
18 FIGURE 1-10 Installing CMA Cable Hangers CMA cable hanger CMA arm Attaching and Routing Cables Use this procedure to attach cables to your server and route them through the CMA. 1. Refer to Installing Cables on page 13 for an illustration of the server back panel ports and a procedure for installing cables to your server. 2. Install cables to your server, as required. 3. Route the cables through the CMA cable hangers. Verifying Operation of the Slide Rails and CMA Use this procedure to ensure that the slide-rails and CMA are operating correctly. 12 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
19 Note Two people are recommended for this procedure: one to move the server in and out of the rack and one to observe the cables and CMA. 1. Slowly pull the server out of the rack until the slide-rails reach their stops. 2. Inspect the attached cables for any binding or kinks. 3. Verify that the CMA extends fully and does not bind in the slide-rails. 4. Push the server back into the rack, as described below. When the server is fully extended, you must release two sets of slide-rail stops to return the server to the rack: a. The first set of stops are levers, located on the inside of each slide-rail, just behind the rear panel of the server. These levers are labeled PUSH. Push in both levers simultaneously and slide the server toward the rack. The server will travel approximately 15 inches (38 cm) and stop. Verify that the cables and the CMA retract without binding before continuing. b. The second set of stops are the slide-rail release buttons, located near the front of each mounting bracket. See FIGURE 1-4. Simultaneously push or pull both of the slide-rail release buttons and push the server completely into the rack until both slide-rail locks engage. 5. Adjust the cable hangers and CMA as required. 6. Continue with Installing Cables on page 13. Installing Cables Attach cables to the back panel connectors of your server as required. See FIGURE 1-11 or FIGURE Chapter 1 Setting Up the Server Hardware 13
20 FIGURE 1-11 Sun Fire X4100/X4100 M2 Server Back Panel AC power connectors (2) Ethernet port NET MGT Gigabit Ethernet ports (4) Video connector SERIAL MGT port USB connectors (2) FIGURE 1-12 Sun Fire X4200/X4200 M2 Server Back Panel AC power connectors (2) Ethernet port NET MGT Gigabit Ethernet ports (4) NET MGT Video connector USB connectors (2) SERIAL MGT port 1. If desired, connect a USB keyboard cable to a USB connector. 2. If desired, connect a USB mouse cable to a USB connector. 3. If desired, connect a video monitor cable to the video connector. Note Keyboard, mouse, and video are optional with an operating system that supports headless operation. Note The system console supports only a screen resolution of 1024 by 768 and a color depth of 24 bits. This limitation is necessary to support video redirection by the Integrated Lights Out Manager (ILOM). 14 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
21 4. Connect Ethernet cables to the NET connectors as required for your Gigabit Ethernet or management network. Note the following guidelines regarding the Ethernet (LAN) ports: The port labeled NET MGT is a 10/100 Ethernet port that can connect your system to a management network. The ports labeled NET 0 through NET 3 are Gigabit Ethernet ports. The order in which the BIOS detects the Ethernet ports during bootup and the corresponding drivers that control those ports are listed below. Sun Fire X4100/X4200 servers: 1. NET 0 (Intel NIC 0) 2. NET 1 (Intel NIC 1) 3. NET 2 (Intel NIC 2) 4. NET 3 (Intel NIC 3) Sun Fire X4100 M2/X4200 M2 servers: 1. NET 0 (Nvidia CK8-04 NIC) 2. NET 1 (Nvidia IO-04 NIC) 3. NET 2 (Intel NIC) 4. NET 3 (Intel NIC) See Connecting to the ILOM Service Processor on page 21 for additional information about setting up the service processor for remote system management. 5. If desired, connect an RJ-45 serial port cable to the SERIAL MGT connector. Note the following considerations for the serial port and serial port cabling: The default serial port speed is 9600 baud with no flow control. These servers use the same pinout as the RJ45 port on the RSC/ALOM/ALOM Plus cards on Sun Netra and other Sun Fire systems. There is a compatible Sun RJ45-to-DB9 adapter shipped with the server, part number An alternative, compatible cable is the Cisco console cable. 6. Continue with Powering On and Off the Server on page 16. Chapter 1 Setting Up the Server Hardware 15
22 Powering On and Off the Server You have to apply only standby power to the server at this point so that you can perform initial configuration o f the service processor. Procedures for powering on to main power mode and for shutting down from main power mode are also included in this section. Applying Standby Power for Initial Service Processor Configuration Use this procedure to apply standby power to the service processor (SP) before initial configuration. Caution Do not operate the server without all fans, component heatsinks, air baffles, and the cover installed. Severe damage to server components can occur if operated without adequate cooling mechanisms. 1. Connect grounded AC power cords to the AC power connectors on the back panel of the server and to grounded AC power outlets. In standby power mode, the Power/OK LED on the front panel flashes, indicating that the SP is working. See FIGURE 1-13 or FIGURE 1-14 for the LED location. Note At this point, standby power is supplied only to the Graphics Redirect and Service Processor (GRASP) board and power supply fans. You can proceed to Chapter 2 to begin initial configuration. Do not apply main power to the rest of the server until you are ready to install a platform operating system. 2. Continue with initial software setup tasks, as described in Chapter 2. Powering On Main Power Mode To power on main power for all server components: 1. Verify that power cords have been connected and that standby power is on. In standby power mode, the Power/OK LED on the front panel flashes. See FIGURE 1-13 or FIGURE Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
23 2. Use a ballpoint pen or other stylus to press and release the recessed Power button on the server front panel. When main power is applied to the full server, the Power/OK LED next to the Power button lights and remains lit. FIGURE 1-13 Sun Fire X4100/X4100 M2 Server Front Panel Power/OK LED Power button FIGURE 1-14 Sun Fire X4200/X4200 M2 Server Front Panel Power/OK LED Power button Shutting Down Main Power Mode To power off the server from main power mode, use one of the following two methods: Graceful shutdown: Use a ballpoint pen or other stylus to press and release the Power button on the front panel. This causes Advanced Configuration and Power Interface (ACPI) enabled operating systems to perform an orderly shutdown of the operating system. Servers not running ACPI-enabled operating systems will shut down to standby power mode immediately. Emergency shutdown: Press and hold the Power button for four seconds to force main power off and enter standby power mode. When main power is off, the Power/OK LED on the front panel flashes, indicating that the server is in standby power mode. Chapter 1 Setting Up the Server Hardware 17
24 Caution To completely power off the server, you must disconnect the AC power cords from the back panel of the server. 18 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
25 CHAPTER 2 Setting Up the Server Software This chapter describes the tasks for initial setup of the server s service processor and Integrated Lights Out Manager software. This chapter contains these topics: Introduction to the Integrated Lights Out Manager on page 19 Connecting to the ILOM Service Processor on page 21 Setting Up Platform Operating System and Driver Software on page 28 Drivers for Option Cards on page 29 Introduction to the Integrated Lights Out Manager The Integrated Lights Out Manager (ILOM) provides powerful tools for managing your server. 19
26 FIGURE 2-1 Integrated Lights Out Manager Login Page ILOM consists of four components, three of which are on your host server and one that is on the client system that accesses your host server. The four components are as follows: ILOM SP hardware. Your server is equipped with a Graphics Redirect and Service Processor (GRASP) board that performs the following functions: Monitors the status and configuration of field-replaceable components of your server, such as fans, disk drives, and power supplies. Provides serial and Ethernet connections to external terminals or local area networks (LANs). ILOM SP firmware. Preinstalled on the GRASP board is a library of system management firmware applications. This ILOM firmware is operating system independent. These firmware applications provide the following system management interfaces into your server: A web-based graphical interface A Secure Shell (SSH) command-line interface An IPMI v2.0 command interface A Simple Network Management Protocol (SNMP) v1, v2c, or v3 interface These interfaces call the same underlying system management functions on your GRASP board, so you can choose to work with one or more of these ILOM interfaces to integrate with the other management interfaces running in your data center. Remote Console application. The Remote Console application allows remote clients to view the graphical console of your host server as though they were directly attached to its video connector. The Remote Console is a mirror of the 1024x768 output from the server s VGA video connector. The remote keyboard, mouse, CD drive, or diskette drive will appear as standard USB devices. 20 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
27 Note The Remote Console application is not required on the client systems, but a web browser and Sun Java runtime environment version 5.0 or later are required on the client systems. You can download Java free from Client-side Secure Shell application. To access the ILOM SP through a remote Secure Shell (SSH), you must install a Secure Shell communications application on the remote client system (server, workstation, or laptop). Many Secure Shell communications applications are available from commercial or open-source distribution. Refer to for information about opensource client-side SSH applications. Sun Microsystems has configured the ILOM hardware and firmware on your server to reflect the most common default settings used in the field. It is unlikely that you will need to change these defaults. Connecting to the ILOM Service Processor There are two methods for connecting to the ILOM SP to perform initial setup and configuration. Use the procedure that you prefer: Connecting to ILOM Using a Serial Connection on page 21 Connecting to ILOM Using an Ethernet Connection on page 23 Connecting to ILOM Using a Serial Connection Use this procedure to establish a serial connection to the ILOM SP so that you can perform initial configuration of ILOM. Note This procedure assumes that you have already completed the hardware setup and have applied standby power to your server, as described in Chapter Verify that your terminal, laptop, or terminal server is operational. 2. Configure that terminal device or the terminal emulation software running on a laptop or PC to the following settings: 8N1: eight data bits, no parity, one stop bit 9600 baud Chapter 2 Setting Up the Server Software 21
28 Disable hardware flow control (CTS/RTS) Disable software flow control (XON/XOFF) 3. Connect a serial cable from the RJ-45 SERIAL MGT port on the server s back panel to a terminal device. See FIGURE 1-11 or FIGURE 1-12 for the location of this port. 4. Press Enter on the terminal device to establish a connection between that terminal device and the ILOM SP. The SP eventually displays a login prompt, such as the following example: SUNSP0003BA84D777 login: In this example login prompt: The string SUNSP is the same for all SPs. 0003BA84D777 is the Ethernet MAC address of the particular SP. This will be different for each server. 5. Log in to the ILOM. a. Type the default user name: root b. Type the default password: changeme. Once you have successfully logged in, the SP displays its default command prompt: -> You can now run CLI commands to configure ILOM for the server s user accounts, network settings, access lists, alerts, and so on. For detailed instructions on CLI commands, see the Integrated Lights-Out Manager Administration Guide, For instructions on configuring static network settings using the CLI, see Configuring Static IP Addresses Using the CLI on page To start the serial console, you can type: cd /SP/console start Note You can switch back to the SP CLI from the serial console by entering the Esc ( key sequence. 7. After configuring the server, continue with Setting Up Platform Operating System and Driver Software on page Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
29 Connecting to ILOM Using an Ethernet Connection To access the full range of ILOM functionality such as the graphical user interface (GUI), you must connect a LAN to the Ethernet port and configure your Ethernet connection. ILOM supports Dynamic Host Configuration Protocol (DHCP) and static IP addressing. To configure using DHCP, see Configuring ILOM Ethernet Settings Using DHCP on page 23. To configure using a static IP address, see Configuring ILOM Using Static Ethernet Settings on page 26. Configuring ILOM Ethernet Settings Using DHCP Note This procedure assumes that you have already completed the hardware setup and have applied standby power for your server, as described in Chapter Verify that your DHCP server is configured to accept new media access control (MAC) addresses by checking with your system administrator. 2. Connect an Ethernet cable to the server s RJ-45 NET MGT Ethernet port. See FIGURE 1-11 or FIGURE If the ILOM SP is not using static IP addresses, it broadcasts a DHCPDISCOVER packet with the ID of its MAC address. A DHCP server on your LAN returns a DHCPOFFER packet containing an IP address and other information. The ILOM SP then manages its lease of that IP address that was assigned to it by the DHCP server. 3. Obtain the ILOM SP IP address from one of the following locations. Record the IP address for future reference. CLI commands. The SP has a serial port to which you can attach a terminal device. If you log in to the SP and enter the CLI command show /SP/network, the SP displays the current IP address. The system BIOS setup screen. Press F2 during bootup, then choose Advanced IPMI 2.0 Configuration Set LAN Configuration IP address. DHCP server log files. If you use this method, use Step a through Step c below. Otherwise, skip to Step 4. Chapter 2 Setting Up the Server Software 23
30 a. Identify the MAC address of the ILOM SP from one of the following locations and write it down: 1. CLI commands. The SP has a serial port to which you can attach a terminal device. If you log in to the SP and type the CLI command show /SP/network, the SP displays the current MAC address. 2. The Customer Information Sheet that is shipped with your server. 3. The system BIOS setup screen. Press F2 during bootup, then choose Advanced IPMI 2.0 Configuration Set LAN Configuration MAC address. b. Log in to your DHCP server and view its DHCP log file. Note Different DHCP server applications running on different operating systems store these log files in different locations. Consult your DHCP system administrator to locate the correct path to the log file. c. Identify the IP address in the log file that corresponds to the MAC address of your ILOM SP. Typically, DHCP log file entries are individual lines with the following commaseparated fields: ID, Date, Time, Description, IP Address, Host Name, MAC Address Locate the MAC address of your ILOM SP in the MAC Address (seventh) field of the correct DHCP file entry and record the corresponding value of the IP Address (fifth) field. This is the IP address that you must use to access the system management firmware applications on your ILOM SP. 4. Open a session to the ILOM SP using the IP address that you obtained in Step 3. You can use the CLI or the GUI interface. To establish a Secure Shell (SSH) connection to the ILOM SP CLI, type the appropriate connection command in the SSH application. For example, to connect to the SP with the DHCP-assigned IP address of , type the following command: # ssh -l root The default user name is root, which was included in the ssh command. When you are prompted, enter the default password for the SP, changeme. You can then enter commands to manage user accounts or to monitor the status of devices on your server. See the example in FIGURE Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
31 FIGURE 2-2 Opening a Session With an SSH Command-Line Interface To establish a connection to the ILOM SP web GUI, type the IP address of the ILOM SP in the browser locator box and press Enter. For example, if the IP address for your ILOM SP was , you would enter it as shown in FIGURE 2-3. The first GUI page prompts you for the default username, root, and the default password, changeme. FIGURE 2-3 Opening a Session With a Web GUI 5. After you have entered the user name and password in either the CLI or GUI, you can use the interface to configure your ILOM SP. For detailed instructions on configuring your system, see the Integrated Lights-Out Manager Administration Guide, Continue with Setting Up Platform Operating System and Driver Software on page 28. Chapter 2 Setting Up the Server Software 25
32 Configuring ILOM Using Static Ethernet Settings As an alternative to having your DHCP server assign an IP address to your ILOM SP, you can also assign a static IP address to it. You can do this by using the web GUI, by using the CLI over the network or serial port, or by using the server s BIOS Setup Utility. Use the procedure you prefer. Configuring Static IP Addresses Using the Web GUI on page 26 Configuring Static IP Addresses Using the CLI on page 27 Configuring Static IP Addresses Using the BIOS Setup Utility on page 28 Configuring Static IP Addresses Using the Web GUI 1. Determine the current IP address of the ILOM SP from one of the following locations: CLI command. The SP has a serial port to which you can attach a terminal device. If you log in to the SP and enter the CLI command show /SP/network, the SP displays the current IP address. The system BIOS setup screen. Press F2 during bootup, then choose Advanced IPMI 2.0 Configuration Set LAN Configuration IP address. 2. Connect to the ILOM SP through a web browser running on a remote system. 3. Log in to the web GUI using the default user name, root, and the default password, changeme. 4. Choose the Configuration tab and its Network tab to display information about the current network configuration of your ILOM SP. See FIGURE Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
33 5. Select the Use the Following IP Address option and type your static IP address information. See the example in FIGURE 2-4. FIGURE 2-4 Integrated Lights Out Manager Network Settings Page Configuring Static IP Addresses Using the CLI 1. Log into the CLI using SSH or by connecting to the serial port. To establish a Secure Shell (SSH) connection to the ILOM CLI, type the appropriate connection command in the SSH application. For example, to connect to the SP with the DHCP-assigned IP address of , you would type the following command: # ssh -l root See the example in FIGURE Type the following commands, using your own addresses in place of the examples below: (The addresses shown in the commands below are examples.) cd /SP/network set pendingipaddress= set pendingipnetmask= set pendingipgateway= set pendingipdiscovery=static set commitpending=true Chapter 2 Setting Up the Server Software 27
34 Configuring Static IP Addresses Using the BIOS Setup Utility 1. Enter the BIOS Setup utility by pressing the F2 key while the system is booting up and performing the power-on self-test (POST). 2. When the BIOS Main menu screen is displayed, select Advanced. 3. From the Advanced menu screen, select IPMI 2.0 Configuration. 4. From the IPMI 2.0 Configuration screen, select LAN Configuration. 5. On the LAN Configuration screen, change the IP Assignment field to Static. 6. Type the static IP address in the IP Address field. You can also enter the subnet mask and default gateway settings in their respective fields. 7. Select Commit and press Return to commit the changes. 8. Select Refresh and press Return to see your new static IP settings displayed in the Current IP address in BMC field. 9. Press and release the right arrow key until the Exit menu screen is displayed. 10. Follow the instructions on the Exit menu screen to save your changes and exit the Setup utility. Setting Up Platform Operating System and Driver Software After configuring the ILOM SP with network settings, you can configure the preinstalled Solaris 10 operating system, or install a supported Linux or Windows platform operating system and drivers. If you want to use the preinstalled Solaris 10 operating system, refer to Configuring the Preinstalled Solaris 10 Operating System on page 36. For details about installing a supported Linux or Solaris OS and the required drivers, refer to Sun Fire X4100/X4200 Servers Operating System Installation Guide, For details about installing a supported Windows OS and the required drivers, refer to Sun Fire X4100/X4200 Servers Windows Operating System Installation Guide, Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
35 For additional OS considerations specific to this server, refer to one of the following: Sun Fire X4100/X4200 Servers Product Notes, Sun Fire X4100 M2/X4200 M2 Servers Product Notes, Drivers for Option Cards Option cards supported by operating systems are listed on the platform-specific product webpage under Companion Products. To check if the driver of your option card is available for download, check the Option Cards link on the Product Page. For example, Sun Fire X4100 M2 platform page and related option card are: For complete platform listings please visit: Chapter 2 Setting Up the Server Software 29
36 30 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
37 CHAPTER 3 Configuring the Preinstalled Solaris 10 Operating System This chapter explains the steps for configuring the Solaris 10 Operating System (OS) that has been preinstalled on your server. The factory-installed version is Solaris 10 6/06 or later. Before You Begin Before you begin configuring the preinstalled OS, you need to do the following: 1. Perform initial configuration of the server s Integrated Lights Out Manager (ILOM) Service Processor (SP) and determine the server s network settings, as described in Connecting to the ILOM Service Processor on page Gather the information that you will need for the configuration, as listed in Installation Worksheet on page Select your console output. For details, see Selecting Your Console Output on page
38 Installation Worksheet Use the worksheet in TABLE 1 to gather the information you need to configure the preinstalled Solaris 10 OS. You need to collect only the information that applies to your application. TABLE 1 Worksheet for Installation Information for Installation Description or Example Your Answers: Defaults are noted with an asterisk. (*) Language Locale Terminal Choose from the list of available languages for the Solaris 10 software. Choose your geographic region from the list of available locales. Choose the type of terminal that you are using from the list of available terminal types. English* English (C - 7-bit ASCII)* Network connection Is the system connected to a network? Networked Non-networked* DHCP If you are not using DHCP, note the network address: Host name Kerberos IP address Subnet Can the system use Dynamic Host Configuration Protocol (DHCP) to configure its network interfaces? If you are not using DHCP, supply the IP address for the system. Example: If you are not using DHCP, is the system part of a subnet? If yes, what is the netmask of the subnet? Example: Yes No* * IPv6 Do you want to enable IPv6 on this machine? Yes No* A host name that you choose for the system. Do you want to configure Kerberos security on this machine? If yes, gather the following information: Default Realm: Administration Server: First KDC: (Optional) Additional KDCs: Yes No* 32 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
39 TABLE 1 Worksheet for Installation (Continued) Information for Installation Description or Example Your Answers: Defaults are noted with an asterisk. (*) Name service: if the system uses a name service, provide the following information. Name service Which name service should this system use? NIS+ NIS DNS LDAP None* Domain name Provide the name of the domain in which the system resides. NIS+ and NIS DNS LDAP Do you want to specify a name server or let the installation program find one? Provide IP addresses for the DNS server. You must enter at least one IP address, but you can enter up to three addresses. You can also enter a list of domains to search when a DNS query is made. Search Domain: Search Domain: Search Domain: Provide the following information about your LDAP profile: Profile name: Profile server: If you specify a proxy credential level in your LDAP profile, gather this information: Proxy-Bind Distinguished Name: Proxy-Bind Password: Specify One Find One* Chapter 3 Configuring the Preinstalled Solaris 10 Operating System 33
40 TABLE 1 Worksheet for Installation (Continued) Information for Installation Default route Description or Example Do you want to specify a default route IP address or let the Solaris installation program find one? The default route provides a bridge that forwards traffic between two physical networks. An IP address is a unique number that identifies each host on a network. You have the following choices: You can specify the IP address. An /etc/defaultrouter file is created with the specified IP address. When the system is rebooted, the specified IP address becomes the default route. You can let the Solaris installation program detect an IP address. However, the system must be on a subnet that has a router that advertises itself by using the ICMP router discovery protocol. If you are using the command-line interface, the software detects an IP address when the system is booted. You can choose None if you do not have a router or do not want the software to detect an IP address at this time. The software automatically tries to detect an IP address on reboot. Your Answers: Defaults are noted with an asterisk. (*) Specify One Detect One None* Time zone How do you want to specify your default time zone? Geographic region* Offset from GM Time zone file Root password Choose a root password for the system. 34 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
41 Selecting Your Console Output Unlike with SPARC systems, you will not see the output of the preinstalled Solaris 10 image through a monitor when you power on the server. Instead, the output of the preinstalled image is directed to a serial console. GRUB, the open source boot loader, is the default boot loader. The boot loader is the first software program that runs after you power on a system. From the GRUB menu, you have the option of displaying the installation process to a VGA connection (video port), as shown below. ******************************************************************* * Solaris 10 11/06 s10x_u2wos_09a X86 * * Solaris failsafe * * Solaris 10 11/06 s10x_u2wos_09a X86 (VGA) * * * * * * * * * * * ******************************************************************* Note The first line of the above figure shows the default startup mode. Example To display output to the video port, choose the following option: Solaris 10 11/06 s10x_u2wos_09a X86 (VGA) Chapter 3 Configuring the Preinstalled Solaris 10 Operating System 35
42 Configuring the Preinstalled Solaris 10 Operating System Note Before you perform this procedure, you need to set up the service processor. If you have not done so, see Before You Begin on page 31. Use the information that you gathered in Installation Worksheet on page 32 as you perform the configuration. After configuring the ILOM SP, you can configure the preinstalled Solaris 10 operating system (OS) by using another system to connect to the server, or install a Linux or Windows platform operating system. The possible ways to do this are described here: To Connect to the Server Using the Service Processor s IP Address on page 37 If you use this method, you first need to determine the service processor s IP address and the server must be connected to the network. To Connect to the Server Using a Terminal Program on page 38 If you use this method, you do not need to determine the service processor s IP address, but you will need to have a cable connection from the server to the serial port of a host system. If you want to install a supported Windows or Linux OS and the required drivers, refer to the following: For Windows: Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Windows Operating System Installation Guide, For Linux (and Solaris): Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Operating System Installation Guide, For additional OS considerations specific to this server, refer to either of the following: Sun Fire X4100/X4200 Servers Product Notes, Sun Fire X4100 M2/X4200 M2 Servers Product Notes, Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
43 To Connect to the Server Using the Service Processor s IP Address Note This procedure assumes that you have connected the server to your network through an Ethernet cable. 1. If you have not already done so, determine the service processor s IP address: a. Power on main power to the platform by using a stylus to press the recessed Power button on the front panel. POST messages appear on your screen as the OS boots up. b. Initialize the BIOS Setup utility by pressing the F2 key while the system is performing the power-on self-test (POST). c. When the main BIOS screen is displayed, select Advanced. d. When the Advanced screen is displayed, select IPMI 2.0 Configuration. When the IPMI 2.0 Configuration screen is displayed, select the LAN Configuration menu item. e. Select the IP Address menu item. The service processor s IP address is displayed using the following format: Current IP address in BMC: xxx.xxx.xxx.xxx 2. Using a client system, establish a Secure Shell (SSH) connection to the service processor s IP address. ssh -l root sp_ip_address 3. Log in to the service processor as an Administrator, for example: login: root password: changeme 4. To make Solaris display on the server VGA (video port), you must select it from the GRUB boot loader menu, shown on page 35. To access the server serial port, you must connect to the ILOM service processor CLI, and type: start /SP/console You may connect to the ILOM service processor CLI, using the serial management port on the rear of the server, or by using ssh over the network. 5. If you have changed the SP serial port default settings, make sure you reset them to the default settings. Chapter 3 Configuring the Preinstalled Solaris 10 Operating System 37
44 6. Follow the Solaris 10 on-screen prompts. Use the information gathered in Installation Worksheet on page 32 to help you enter the system and network information as you are prompted. The screens that are displayed will vary, depending on the method that you chose for assigning network information to the server (DHCP or static IP address). After you have entered the system-configuration information, the server completes the boot process and displays the Solaris login prompt. To Connect to the Server Using a Terminal Program 1. Use a cable to connect the serial port of the server to the serial port of the host system. 2. Make sure the communication properties of the serial port of the system are set to the default. The default settings are 9600 baud, 8N1 (eight data bits, no parity, one stop bit), disable flow control. 3. Start a terminal session to capture the serial port output: On a client running Solaris OS, type: $tip /dev/ttya On a client running Windows, start a program such as Hyperterminal. On a client running Linux, start a program such as Minicom, a text-based serial communication program that is included in the Linux distributions. For more information, see the man pages included in the Linux distribution. 4. Log in to the service processor as an Administrator, for example: login: root password: changeme 5. Start the ILOM SP GUI by entering the following: start /SP/console 6. Power on main power to the server by using a nonmetalic stylus to press the recessed Power button on the front panel. POST messages appear on your screen as the OS boots up. 38 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
45 7. Follow the Solaris 10 preinstallation on-screen prompts. Use the information gathered in Installation Worksheet on page 32 to help you enter the system and network information as you are prompted. The screens that are displayed will vary, depending on the method that you chose for assigning network information to the server (DHCP or static IP address). After you have entered the system-configuration information, the server completes the boot process and displays the Solaris login prompt. Solaris 10 User Documentation You can access the various collections of the Solaris 10 OS user documentation at: Specifically, you can access the Solaris 10 OS Release and Installation Collection at: Downloading Solaris 10 OS Software If you need to re-install the Solaris 10 OS after removing it, you can download the CD or DVD image. To download the CD or DVD image, see: Solaris 10 OS Training Sun provides flexible training options that accommodate your personal schedule and learning style. The training options include instructor-led, web-based online, CD-ROM and Live Virtual Class. For Solaris 10 training and certification options at a glance, please visit: Chapter 3 Configuring the Preinstalled Solaris 10 Operating System 39
46 40 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
47 Index B back panel cable connectors, 13 back panel illustration, 13 C cable management assembly, 7 cables, 13 Cisco console cable, 15 client-side secure shell, 21 CMA assembly, 7 connectors, back panel, 13 D default serial port speed, 15 driver updates, vi Drivers for Option Cards, 29 E emergency shutdown, 18 Ethernet connection to service processor, 23 Ethernet ports, 15 F firmware updates, vi flow control, 15 G Gigabit Ethernet ports, 15 graceful shutdown, 17 H headless operation, 14 I ILOM client-side secure shell, 21 configuring with Ethernet, 23 configuring with serial, 21 configuring with static Ethernet, 26 introduction, 19 remote console application, 20 service processor firmware, 20 service processor hardware, 20 software components, 20 installation overview, 1 installing to a rack, 2 Integrated Lights Out Manager, see ILOM Intel NIC, 15 M main power, applying, 16 N NET connectors, 15 Nvidia CK8-04 NIC, 15 O OS installation, references, 28 overview of installation, 1 41
48 P power powering off, 17 powering on main power, 16 powering on standby power, 16 product updates, vi R rack installation, 2 remote console application, 20 RJ45 port, 15 S screen resolution, 14 serial connection to service processor, 21 service processor configuring with Ethernet, 23 configuring with serial, 21 firmware, 20 hardware, 20 shutting down power, 17 slide-rail installation, 3 standby power, applying, 16 static Ethernet configuration, 26 Sun RJ45-to-DB9 adapter, 15 V video monitor cable, 14 video redirection, Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation December 2008
Sun Cobalt Control Station. Using the LCD Console
Sun Cobalt Control Station Using the LCD Console Copyright 1997-2001 Sun Microsystems, Inc., 901 San Antonio Road, Palo Alto, California 94303-4900 U.S.A. All rights reserved. Sun Microsystems, Inc. has
Sun Management Center Change Manager 1.0.1 Release Notes
Sun Management Center Change Manager 1.0.1 Release Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 817 0891 10 May 2003 Copyright 2003 Sun Microsystems, Inc. 4150
Sun Management Center 3.6 Version 5 Add-On Software Release Notes
Sun Management Center 3.6 Version 5 Add-On Software Release Notes For Sun Fire, Sun Blade, Netra, and Sun Ultra Systems Sun Microsystems, Inc. www.sun.com Part No. 819-7977-10 October 2006, Revision A
Sun Ray, Smart Cards, and Citrix
Sun Ray, Smart Cards, and Citrix Enabling Sun Ray Smart Card Pass-through to Citrix Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 May 2004, Version 1.0 Copyright
Sun Fire V20z Server Release Notes
Sun Fire V20z Server Release Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 817-5252-10 March, 2004 Revison A Submit comments about this document at:
Solaris 10 Documentation README
Solaris 10 Documentation README Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 817 0550 10 January 2005 Copyright 2005 Sun Microsystems, Inc. 4150 Network Circle, Santa
Sun Enterprise Optional Power Sequencer Installation Guide
Sun Enterprise Optional Power Sequencer Installation Guide For the Sun Enterprise 6500/5500 System Cabinet and the Sun Enterprise 68-inch Expansion Cabinet Sun Microsystems, Inc. 901 San Antonio Road Palo
Solaris 9 9/05 Installation Roadmap
Solaris 9 9/05 Installation Roadmap This document is a guide to the DVD-ROM, CD-ROMs, and documents involved in installing the Solaris 9 9/05 software. Unless otherwise specified, this document refers
Sun Fire V20z and Sun Fire V40z Servers Differences Between Server Versions
Sun Fire V20z and Sun Fire V40z Servers Differences Between Server Versions This document compares the released versions of the Sun Fire V20z and Sun Fire V40z servers. This document includes the following
Sun TM SNMP Management Agent Release Notes, Version 1.6
Sun TM SNMP Management Agent Release Notes, Version 1.6 Sun Microsystems, Inc. www.sun.com Part No. 820-5966-12 December 2008, Revision A Submit comments about this document by clicking the Feedback[+]
Sun Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Fire X4150, X4250 and X4450 Servers
Sun Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Fire X4150, X4250 and X4450 Servers Sun Microsystems, Inc. www.sun.com Part No. 820-7842-11 November 2009, Revision A Submit comments
Sun Management Center 3.6 Version 4 Add-On Software Release Notes
Sun Management Center 3.6 Version 4 Add-On Software Release Notes For Sun Fire, Sun Blade, Netra, and Sun Ultra Systems Sun Microsystems, Inc. www.sun.com Part No. 819-4989-10 July 2006, Revision A Submit
SunFDDI 6.0 on the Sun Enterprise 10000 Server
SunFDDI 6.0 on the Sun Enterprise 10000 Server Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No.: 806-3610-11 November 1999, Revision A Send
Sun Blade 150 CD-ROM, DVD-ROM, and Hard Drive Installation Guide
Sun Blade 150 CD-ROM, DVD-ROM, and Hard Drive Installation Guide Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 816-5369-10 June 2002, Revision A Send comments
Sun StorEdge Availability Suite Software Point-in-Time Copy Software Maximizing Backup Performance
Sun StorEdge Availability Suite Software Point-in-Time Copy Software Maximizing Backup Performance A Best Practice Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part
N1 Grid Service Provisioning System 5.0 User s Guide for the Linux Plug-In
N1 Grid Service Provisioning System 5.0 User s Guide for the Linux Plug-In Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 819 0735 December 2004 Copyright 2004 Sun Microsystems,
Sun SNMP Management Agent Release Notes, Version 1.5.5
Sun SNMP Management Agent Release Notes, Version 1.5.5 Sun Microsystems, Inc. www.sun.com Part No. 820-0174-15 June 2008, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Sun Blade 100 CD-ROM or DVD-ROM and Hard Disk Drive Installation Guide
Sun Blade 100 CD-ROM or DVD-ROM and Hard Disk Drive Installation Guide Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 806-6637-12 January 2002, Revision A
Sun Management Center 3.5 Update 1b Release Notes
Sun Management Center 3.5 Update 1b Release Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 819 3054 10 June 2005 Copyright 2005 Sun Microsystems, Inc. 4150 Network
Sun Fire X4100 M2/X4200 M2 Servers Release Notes for Software Release 1.1
Sun Fire X4100 M2/X4200 M2 Servers Release Notes for Software Release 1.1 Sun Microsystems, Inc. www.sun.com Part No. 820-2533-10 March 2007, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback
RAID Controller PCI Card for the Sun Fire V60x and V65x Servers Release Notes
RAID Controller PCI Card for the Sun Fire V60x and V65x Servers Release Notes CAUTION: Read this document before installing the RAID Controller PCI Card. Failure to use the correct firmware version with
Sun StorEdge A5000 Installation Guide
Sun StorEdge A5000 Installation Guide for Windows NT Server 4.0 Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No. 805-7273-11 October 1998,
Sun Integrated Lights Out Manager Supplement for the Sun Fire X4450 Server
Sun Integrated Lights Out Manager Supplement for the Sun Fire X4450 Server Sun Microsystems, Inc. www.sun.com Part No. 820-4997-10 September 2008, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Veritas Storage Foundation 5.0 Software for SPARC
Veritas Storage Foundation 5.0 Software for SPARC Release Note Supplement Sun Microsystems, Inc. www.sun.com Part No. 819-7074-10 July 2006 Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Distributed Application Management using Jini Connection Technology
Distributed Application Management using Jini Connection Technology The Jini Technology Enabled Applications Manager provides a framework, utilizing Jini and JavaSpaces technologies, for selecting and
Sun StorEdge Enterprise Backup Software 7.2
Sun StorEdge Enterprise Backup Software 7.2 Update Guide Sun Microsystems, Inc. www.sun.com Part No. 819-4089-10 September 2005, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Sun Integrated Lights Out Manager 2.0 User s Guide
Sun Integrated Lights Out Manager 2.0 User s Guide Sun Microsystems, Inc. www.sun.com Part No. 820-1188-12 September 2008, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Sun StorEdge network FC switch-8 and switch-16 Release Notes
Sun StorEdge network FC switch-8 and switch-16 Release Notes Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 806-6924-14 February 2001, Revision A Send
SUN SEEBEYOND egate INTEGRATOR RELEASE NOTES. Release 5.1.1
SUN SEEBEYOND egate INTEGRATOR RELEASE NOTES Release 5.1.1 Copyright 2006 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun Microsystems, Inc.
Java Device Test Suite Local Relay User s Guide
Java Device Test Suite Local Relay User s Guide Version 2.4 Java ME Platform Sun Microsystems, Inc. www.sun.com May 2009 Submit comments about this document by clicking the Feedback[+] link at: http://docs.sun.com
Sun Fire B10n Content Load Balancing Blade Product Notes
Sun Fire B10n Content Load Balancing Blade Product Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 817-0628-10 June 2003, Revision A Submit comments
Sun N1 Service Provisioning System User s Guide for Linux Plug-In 2.0
Sun N1 Service Provisioning System User s Guide for Linux Plug-In 2.0 Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 819 4885 10 April 2006 Copyright 2006 Sun Microsystems,
A Strategy for Managing Performance
A Strategy for Managing Performance John Brady, Sun Professional Services Sun BluePrints OnLine December 2002 http://www.sun.com/blueprints Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95045
Sun GlassFish Mobility Platform 1.1 Deployment Guide
Sun GlassFish Mobility Platform 1.1 Deployment Guide Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 820 7205 February 2009 Copyright 2009 Sun Microsystems, Inc. 4150 Network
Sun Fire 6800/4810/4800/3800 Systems Firmware 5.13.3 Release Notes
Sun Fire 6800/4810/4800/3800 Systems Firmware 5.13.3 Release Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 816-7909-10(v2) October 2002, Revision A
Quick Start Guide. Cisco Small Business. 300 Series Managed Switches
Quick Start Guide Cisco Small Business 300 Series Managed Switches Welcome Thank you for choosing the Cisco 300 Series Managed Switch, a Cisco Small Business network communications device. This device
Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.
About This Guide This guide contains step-by-step instructions for setting up the D-Link DFL-260E/860E Firewall. Please note that the model you have purchased may appear slightly different from those shown
Solaris Resource Manager
Solaris Resource Manager By Richard McDougall - Enterprise Engineering Sun BluePrints OnLine - April 1999 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 USA
Sun StorEdge RAID Manager 6.2.21 Release Notes
Sun StorEdge RAID Manager 6.2.21 Release Notes formicrosoftwindowsnt Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No. 805-6890-11 November
RSA Security Analytics. S4 Broker Setup Guide
RSA Security Analytics S4 Broker Setup Guide Copyright 2010-2013 RSA, the Security Division of EMC. All rights reserved. Trademarks RSA, the RSA Logo and EMC are either registered trademarks or trademarks
Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches
Quick Start Guide Cisco Small Business 200E Series Advanced Smart Switches Welcome Thank you for choosing the Cisco 200E series Advanced Smart Switch, a Cisco Small Business network communications device.
SCSI Sense Key Error Guide
SCSI Sense Key Error Guide Sun Microsystems, Inc. www.sun.com Part No. 817-5918-10 February 2004, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback Copyright 2004 Sun
Sun StorEdge N8400 Filer Release Notes
Sun StorEdge N8400 Filer Release Notes Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 U.S.A. 650-960-1300 Part No. 806-6888-10 February 2001, Revision A Send comments about this document
Sun StorEdge Network FC Switch-8 and Switch-16 Release Notes
Sun StorEdge Network FC Switch-8 and Switch-16 Release Notes Sun StorEdge SAN 3.0 Release Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 816-0842-12 February
Sun Ultra TM. 5 and Ultra 10 Product Notes. Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A.
Sun Ultra TM 5 and Ultra 10 Product Notes Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 806-6750-11 November 2000, Revision A Send comments about this
McAfee Firewall Enterprise
Hardware Guide Revision C McAfee Firewall Enterprise S1104, S2008, S3008 The McAfee Firewall Enterprise Hardware Product Guide describes the features and capabilities of appliance models S1104, S2008,
Sun Ray Connector for Windows OS, Version 2.1 Release Notes
Sun Ray Connector for Windows OS, Version 2.1 Release Notes Sun Microsystems, Inc. www.sun.com Part No.820-3777-12 October 2008, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Optimizing Solaris Resources Through Load Balancing
Optimizing Solaris Resources Through Load Balancing By Tom Bialaski - Enterprise Engineering Sun BluePrints Online - June 1999 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road
Intel Active Management Technology with System Defense Feature Quick Start Guide
Intel Active Management Technology with System Defense Feature Quick Start Guide Introduction...3 Basic Functions... 3 System Requirements... 3 Configuring the Client System...4 Intel Management Engine
Netra Data Plane Software Suite 2.0 Update 2 Release Notes
Netra Data Plane Software Suite 2.0 Update 2 Release Notes Sun Microsystems, Inc. www.sun.com Part No. 820-5213-11 July 2008, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Sun GlassFish Enterprise Manager SNMP Monitoring 1.0 Installation and Quick Start Guide
Sun GlassFish Enterprise Manager SNMP Monitoring 1.0 Installation and Quick Start Guide Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 820 7189 January 2009 Copyright
Sun Fire V480 Server Setup and Rackmounting Guide
Sun Fire V480 Server Setup and Rackmounting Guide Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 816-0902-10 February 2002, Revision A Send comments about
Getting StartedWith Sun Java System Application Server 9.1 Update 2
Getting StartedWith Sun Java System Application Server 9.1 Update 2 Student Guide Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. August 2008 Copyright 2008 Sun Microsystems, Inc.
Start Here. Installation and Documentation Reference. Sun StorEdgeTM 6120 Array
Start Here Installation and Documentation Reference Sun StorEdgeTM 6120 Array 1 Access the Online Documentation These documents and other related documents are available online at http://www.sun.com/documentation
How to Set Up Your NSM4000 Appliance
How to Set Up Your NSM4000 Appliance Juniper Networks NSM4000 is an appliance version of Network and Security Manager (NSM), a software application that centralizes control and management of your Juniper
Sun Grid Engine 5.2.3 Release Notes
Sun Grid Engine 5.2.3 Release Notes Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 816-2082-10 July 2001 For more information, go to http://www.sun.com/gridware
Upgrading the Solaris PC NetLink Software
Upgrading the Solaris PC NetLink Software By Don DeVitt - Enterprise Engineering Sun BluePrints OnLine - January 2000 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road Palo Alto,
Sun SM Remote Services Net Connect Solaris TM 9 4/04
Sun SM Remote Services Net Connect Solaris TM 9 4/04 Installation and Activation Guide Sun Microsystems, Inc. www.sun.com Part No. 916-1586 Revision 1.0 May 25, 2004 Submit comments about this document
Solaris 9 Installation Roadmap
Solaris 9 Installation Roadmap This document is a guide to the DVD, CDs and documents involved in installing the Solaris 9 software. Unless otherwise specified, this document refers to both DVDs and CDs
Foglight Experience Monitor and Foglight Experience Viewer
Foglight Experience Monitor and Foglight Experience Viewer Quest Software, Inc. April 2008 Using the Dell Remote Access Controller Copyright Quest Software, Inc. 2008. All rights reserved. This guide contains
Using Linux mdadm Multipathing with Sun StorEdge Systems
Using Linux mdadm Multipathing with Sun StorEdge Systems Sun Microsystems, Inc. www.sun.com Part No. 819-2452-10 April 2005, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Sun Fire V480 Server Product Notes
Sun Fire V480 Server Product Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 816-0905-14 September 2002, Revision A Send comments about this document
Symantec Database Security and Audit 3100 Series Appliance. Getting Started Guide
Symantec Database Security and Audit 3100 Series Appliance Getting Started Guide Symantec Database Security and Audit 3100 Series Getting Started Guide The software described in this book is furnished
User Manual. EtherUSB
User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents
Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA
Quick Start Guide Cisco SPA232D Mobility Enhanced ATA Package Contents Analog Telephone Adapter Ethernet Cable Phone Cable Power Adapter Quick Start Guide Product CD-ROM Welcome Thank you for choosing
Router Setup Manual. NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10060-01 2006-03-17
NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10060-01 2006-03-17 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear, Inc. Microsoft, Windows,
Brocade SilkWorm 4100 FC Switch Release Notes
Brocade SilkWorm 4100 FC Switch Release Notes For Installation in Sun Storage Area Networks, 4.4.0b Firmware Sun Microsystems, Inc. www.sun.com Part No. 819-1672-10 April 2005, Revision A Submit comments
Sun Fire X4600 M2 Server Release Notes For Software Release 1.3a
Sun Fire X4600 M2 Server Release Notes For Software Release 1.3a Sun Microsystems, Inc. www.sun.com Part No. 820-3510-11 December 2007, Revision 01 Submit comments about this document at: http://www.sun.com/hwdocs/feedback
3.5 EXTERNAL NETWORK HDD. User s Manual
3.5 EXTERNAL NETWORK HDD User s Manual Table of Content Before You Use Key Features H/W Installation Illustration of Product LED Definition NETWORK HDD Assembly Setup the Network HDD Home Disk Utility
System Area Manager. Remote Management
System Area Manager Remote Management Remote Management System Area Manager provides remote management functions for its managed systems, including Wake on LAN, Shutdown, Restart, Remote Console and for
Sun Cluster 2.2 7/00 Data Services Update: Apache Web Server
Sun Cluster 2.2 7/00 Data Services Update: Apache Web Server Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 806-6121 July 2000, Revision A Copyright 2000
Quick Start Guide. RV0xx Series Routers
Quick Start Guide RV0xx Series Routers RV042 Dual WAN VPN Router RV042G Gigabit Dual WAN VPN Router RV082 Dual WAN VPN Router RV016 Multi-WAN VPN Router Package Contents VPN Router Power Adapter (Cisco
Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.
Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of
Cisco Expressway CE500 Appliance
Cisco Expressway CE500 Appliance Installation Guide First Published: April 2014 Last Updated: November 2015 X8.2 or later Cisco Systems, Inc. www.cisco.com Introduction About This Document This document
Acano solution. Acano Solution Installation Guide. Acano. January 2014 76-1002-03-B
Acano solution Acano Solution Installation Guide Acano January 2014 76-1002-03-B Contents Contents 1 Introduction... 3 1.1 Before You Start... 3 1.1.1 Safety information... 3 1.1.2 You will need the following
Chapter 1 Installing the Gateway
Chapter 1 Installing the Gateway This chapter describes how to set up the wireless voice gateway on your Local Area Network (LAN), connect to the Internet, and perform basic configuration. For information
Quad-Core CPU Upgrade Kit Installation Guide
Quad-Core CPU Upgrade Kit Installation Guide for the Sun Fire X2200 M2 Server Sun Microsystems, Inc. www.sun.com Part No. 820-3270-13 December 2008 Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Sun Blade 1500 Workstation Product Notes
Sun Blade 1500 Workstation Product Notes (Silver) Silver Sun Microsystems, Inc. www.sun.com Part No. 817-5131-13 April 2005, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Service Level Definitions and Interactions
Service Level Definitions and Interactions By Adrian Cockcroft - Enterprise Engineering Sun BluePrints OnLine - April 1999 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road Palo
Sun StorEdge T3 Dual Storage Array - Part 1
Sun StorEdge T3 Dual Storage Array - Part 1 Installation, Planning, and Design By Mark Garner - Enterprise Engineering Sun BluePrints OnLine - February 2001 http://www.sun.com/blueprints Sun Microsystems,
Quick Start Guide. 500 Series Stackable Managed Switches
Quick Start Guide 500 Series Stackable Managed Switches Welcome Thank you for choosing the Cisco 500 Series Stackable Managed Switch, a Cisco network communications device. This device is designed to be
Quick Start Guide. WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide. Cisco Small Business
Quick Start Guide Cisco Small Business WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide Versión en Español para México en el CD Version en français sur CD Versione
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset) Version: 1.4 Table of Contents Using Your Gigabyte Management Console... 3 Gigabyte Management Console Key Features and Functions...
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
Remote PC Guide for Standalone PC Implementation
Remote PC Guide for Standalone PC Implementation Updated: 2007-01-22 The guide covers features available in NETLAB+ version 3.6.1 and later. IMPORTANT Standalone PC implementation is no longer recommended.
Quick Start Guide. Cisco Small Business. 200 Series 8-Port Smart Switches
Quick Start Guide Cisco Small Business 200 Series 8-Port Smart Switches Welcome Thank you for choosing the Cisco 200 Series 8-Port Smart Switch, a Cisco Small Business network communications device. This
Scrubbing Disks Using the Solaris Operating Environment Format Program
Scrubbing Disks Using the Solaris Operating Environment Format Program By Rob Snevely - Enterprise Technology Center Sun BluePrints OnLine - June 2000 http://www.sun.com/blueprints Sun Microsystems, Inc.
Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
Lotus Foundations Start Getting Started
Lotus Foundations Start Getting Started Guide Contents 1 Introduction... page 2 2 Product overview... page 2 3 System Requirements... page 2 4 Summary of Installation... page 3 5 Lotus Foundations operating
USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks
USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu,
Wireless Router Setup Manual
Wireless Router Setup Manual NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10082-02 2006-04 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear,
SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3
SIP Proxy Server Administrator Installation and Configuration Guide V2.31b 09SIPXM.SY2.31b.EN3 DSG, DSG logo, InterPBX, InterServer, Blaze Series, VG5000, VG7000, IP590, IP580, IP500, IP510, InterConsole,
Thank for choosing the Dominion KX III, the industry's highest performance enterprise-class, secure, digital KVM (Keyboard, Video, Mouse) switch.
QS Rule Dominion KX III Quick Setup Guide Thank for choosing the Dominion KX III, the industry's highest performance enterprise-class, secure, digital KVM (Keyboard, Video, Mouse) switch. This Quick Setup
How To Start A Glassfish V3 Application Server Quick Start 7.2.2 (Windows) On A Microsoft Server (Windows 7)
GlassFish v3 Application Server Quick Start Guide Sun Microsystems, Inc. 450 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 80 4836 0 April 008 Copyright 008 Sun Microsystems, Inc. 450 Network Circle,
Quick Start Guide. DVR DS-7200HWI-SH Series DVR. www.hikvision.com. First Choice For Security Professionals
Quick Start Guide DVR DS-7300HWI-SH Series DVR DS-7200HWI-SH Series DVR NOTE: For more detailed information, refer to the User s Manual on the CD-ROM. You must use your PC or MAC to access the files. www.hikvision.com
An Oracle White Paper April 2010. How to Install the Oracle Solaris 10 Operating System on x86 Systems
An Oracle White Paper April 2010 How to Install the Oracle Solaris 10 Operating System on x86 Systems Introduction... 1 Installation Assumptions... 2 Check the Hardware Compatibility List... 2 Basic System