Quad-Core CPU Upgrade Kit Installation Guide
|
|
|
- Regina Simmons
- 9 years ago
- Views:
Transcription
1 Quad-Core CPU Upgrade Kit Installation Guide for the Sun Fire X2200 M2 Server Sun Microsystems, Inc. Part No December 2008 Submit comments about this document at:
2 Copyright 2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun Microsystems, Inc. has intellectual property rights relating to technology that is described in this document. In particular, and without limitation, these intellectual property rights may include one or more of the U.S. patents listed at and one or more additional patents or pending patent applications in the U.S. and in other countries. This document and the product to which it pertains are distributed under licenses restricting their use, copying, distribution, and decompilation. No part of the product or of this document may be reproduced in any form by any means without prior written authorization of Sun and its licensors, if any. Third-party software, including font technology, is copyrighted and licensed from Sun suppliers. Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in the U.S. and in other countries, exclusively licensed through X/Open Company, Ltd. Sun, Sun Microsystems, the Sun logo, Java, Sun Fire, docs.sun.com, and Solaris are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. and in other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the U.S. and in other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements. U.S. Government Rights Commercial use. Government users are subject to the Sun Microsystems, Inc. standard license agreement and applicable provisions of the FAR and its supplements. DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. Copyright 2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, Californie 95054, États-Unis. Tous droits réservés. Sun Microsystems, Inc. possède les droits de propriété intellectuels relatifs à la technologie décrite dans ce document. En particulier, et sans limitation, ces droits de propriété intellectuels peuvent inclure un ou plusieurs des brevets américains listés sur le site un ou les plusieurs brevets supplémentaires ainsi que les demandes de brevet en attente aux les États-Unis et dans d autres pays. Ce document et le produit auquel il se rapporte sont protégés par un copyright et distribués sous licences, celles-ci en restreignent l utilisation, la copie, la distribution, et la décompilation. Aucune partie de ce produit ou document ne peut être reproduite sous aucune forme, par quelque moyen que ce soit, sans l autorisation préalable et écrite de Sun et de ses bailleurs de licence, s il y en a. Tout logiciel tiers, sa technologie relative aux polices de caractères, comprise, est protégé par un copyright et licencié par des fournisseurs de Sun. Des parties de ce produit peuvent dériver des systèmes Berkeley BSD licenciés par l Université de Californie. UNIX est une marque déposée aux États-Unis et dans d autres pays, licenciée exclusivement par X/Open Company, Ltd. Sun, Sun Microsystems, le logo Sun, Java, Sun Fire, docs.sun.com, et Solaris sont des marques de fabrique ou des marques déposées de Sun Microsystems, Inc. aux États-Unis et dans d autres pays. Toutes les marques SPARC sont utilisées sous licence et sont des marques de fabrique ou des marques déposées de SPARC International, Inc. aux États-Unis et dans d autres pays. Les produits portant les marques SPARC sont basés sur une architecture développée par Sun Microsystems, Inc. L interface utilisateur graphique OPEN LOOK et Sun a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sun reconnaît les efforts de pionniers de Xerox dans la recherche et le développement du concept des interfaces utilisateur visuelles ou graphiques pour l industrie informatique. Sun détient une license non exclusive de Xerox sur l interface utilisateur graphique Xerox, cette licence couvrant également les licenciés de Sun implémentant les interfaces utilisateur graphiques OPEN LOOK et se conforment en outre aux licences écrites de Sun. LA DOCUMENTATION EST FOURNIE "EN L ÉTAT" ET TOUTES AUTRES CONDITIONS, DÉCLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA LIMITE DE LA LOI APPLICABLE, Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE À LA QUALITÉ MARCHANDE, À L APTITUDE À UNE UTILISATION PARTICULIÈRE OU À L ABSENCE DE CONTREFAÇON.
3 Quad-Core CPU Upgrade Kit Installation Guide The instructions provided in this document describe how to use the Quad-Core CPU Upgrade Kits to upgrade your Sun Fire X2200 M2 server from a dual-core CPU configuration to a quad-core CPU configuration. This document includes the following sections: Upgrade Overview on page 2 Required Tools and Supplies on page 5 Upgrading a Dual-Core CPU Server on page 6 Safety Information and ESD Prevention on page 7 Preparing for the Upgrade on page 9 Removals and Replacements on page 14 Preparing for Operation on page 27 Returning Parts to Sun Microsystems on page 31 Note This kit is available as a customer replaceable unit (CRU). If you need assistance, contact your Sun Microsystems service representative. 1
4 Upgrade Overview The procedures in this document describe how to use the quad-core upgrade kits to upgrade a Sun Fire X2200 M2 server from an AMD Opteron Dual-Core CPU configuration to an AMD Opteron Quad-Core or Enhanced Quad-Core CPU configuration. To perform the procedures in this document, you must have the correct kit for your type of upgrade. There are two kits. The kits are designated as: Quad-Core CPU Upgrade Kit Enhanced Quad-Core CPU Upgrade Kit The following table lists the CPU upgrade options that are available using the upgrade kits and this document. To use the table, locate your current configuration and match it to the new configuration. The hardware required is listed in the last column. You can upgrade this CPU Configuration To This CPU Configuration Using this Hardware 2 Dual-Core 2 Quad-Core 1-Quad-Core CPU Upgrade Kit 2 Dual-Core 2 Enhanced Quad-Core 1-Enhanced Quad-Core CPU Upgrade Kit 2 Dual-Core 1 Enhanced Quad-Core 1-Enhanced Quad-Core CPU Upgrade Kit Note - Kit contains two CPUs. Use one CPU in socket CPU0 only. Caution Do not mix CPU types on the same motherboard. The kits are available as dual CPU server configurations only. See the next section, Upgrade Kit Contents, for the kit contents. 2 Quad-Core CPU Upgrade Kit Installation Guide December 2008
5 Upgrade Kit Contents Kit Name Quad-Core CPU Upgrade Kit or Enhanced Quad- Core CPU Upgrade Kit Contents 2 quad-core or enhanced quad-core CPUs 2 heatsinks with pre-applied thermal compound Pre-flashed 1MB firmware PROM Anti-static wrist strap PLCC extraction tool Where to Find Document To order, contact your Sun Account Manager or your Sun authorized reseller. Required Time The time required to complete this upgrade: minutes. Enhanced Quad-Core CPU X-Option In addition to the two quad-core upgrade kits, an Enhanced Quad-Core CPU X- option is also available. The X-option contains one AMD Opteron Enhanced Quad- Core CPU and one heatsink and is used for upgrading from a quad-core CPU to an enhanced quad-core CPU. The X-option provides the following quad-core-to-enhanced quad-core upgrade paths: You can upgrade this Quad-Core CPU Configuration To This Enhanced Quad-Core CPU Configuration Using this X-Option Quantity 2 Quad-Core 2 Enhanced Quad-Core 2-Enhanced Quad-Core CPU X-Options Note - Update to enhanced quad-core BIOS before upgrading. 1 or 2 Quad-Core 1 Enhanced Quad-Core 1-Enhanced Quad-Core CPU X-Option Note - Use one CPU in socket CPU0 only. Update to enhanced quad-core BIOS before upgrading. Quad-Core CPU Upgrade Kit Installation Guide 3
6 Note The Enhanced Quad-Core CPU X-Option does not contain a firmware PROM. The X-Option does not contain a firmware PROM. Therefore, it does not contain the necessary hardware to upgrade a dual-core CPU server to an enhanced quad-core CPU server. For this upgrade path, you must use the Enhanced Quad-Core CPU Upgrade Kit. For CPU replacement procedures using the Enhanced Quad-Core CPU X-option, see the Sun Fire X2200 M2 Server Service Manual. Quad-Core Upgrade-Related Issues This section lists software, hardware, and firmware issues related to upgrading your server from dual-core processors to quad-core processors. 4 GB DIMM and Quad-Core CPU Compatibility Issue Some Micron 4 GB DIMMs supplied for use with dual-core CPU servers can have single-bit or multiple bit errors after the servers are upgraded to quad-core CPUs. Symptoms include system crash and boot failure. Not all existing Micron 4 GB DIMMs are affected. Before you upgrade your server to quad-core CPUs, you should inspect the label on any 4 GB DIMMs installed in your server. Affected DIMMs have the following three identifiers on the label: A Micron product logo A vendor part number of MT36HTF51272PY-667E A manufacture date before the 32nd week of 2008 (200832) For more information, see the Sun Fire X2200 M2 Server Product Notes. 4 Quad-Core CPU Upgrade Kit Installation Guide December 2008
7 Required Tools and Supplies Quad-Core or Enhanced Quad-Core CPU Upgrade Kit Sun Fire X2200 M2 Tools and Drivers CD v2.0 (or later version) (see Downloading the Tools and Drivers CD on page 9) #1 Phillips screwdriver (small size) #2 Phillips screwdriver (standard size) KVM access to the server PLCC extraction tool (included in kit) ESD wrist strap (included in kit) Sun Fire X2200 M2 server product documentation: Sun Fire X2200 M2 Server Product Notes Sun Fire X2200 M2 Server Service Manual Sun Fire X2200 M2 Server Installation Guide Embedded Lights Out Manager Administration Guide for the Sun Fire X2200 M2 and X2100 M2 Servers Sun Fire X2200 M2 server product documentation is available at: Quad-Core CPU Upgrade Kit Installation Guide 5
8 Upgrading a Dual-Core CPU Server Upgrading a dual-core CPU server to a quad-core CPU server involves performing the following steps: Preparing for the Upgrade: 1. Safety Information and ESD Prevention on page 7 2. Reviewing Product Note Documentation on page 9 3. Downloading the Tools and Drivers CD on page 9 4. Recording Your Current BIOS settings on page Preparing the Server for the Upgrade on page Identifying Components on page 12 Removal and Replacement: 1. Removing the Air Duct and Heatsinks on page Removing the CPUs on page Installing the Quad-Core CPUs on page Installing the New Heatsink on page Replacing the Firmware PROM on page Installing the New Firmware PROM on page Clearing CMOS on page 25 Preparing for Operation: 1. Preparing the Server for Operation on page Updating the SP Firmware on page Updating BIOS Firmware on page Performing Power On and BIOS Setup Procedures on page 30 Returning Parts 1. Returning Parts to Sun Microsystems on page 31 6 Quad-Core CPU Upgrade Kit Installation Guide December 2008
9 Safety Information and ESD Prevention Before you begin the upgrade procedure, you must understand the safety information and electrostatic discharge and antistatic prevention measures. Safety Information This section describes important safety information that you need to know prior to removing or installing parts in your Sun Fire X2200 M2 server. Caution Hazardous voltage present. Never attempt to run the server with the covers removed. Caution Equipment damage possible. The covers must be in place for proper air flow. For your protection, observe the following safety precautions when setting up your equipment: Follow all Sun cautions, warnings, and instructions marked on the equipment and described in Important Safety Information for Sun Hardware Systems ( ). Follow all cautions, warnings, and instructions marked on the equipment and described in the Sun Fire X2200 M2 Safety and Compliance Guide. Ensure that the voltage and frequency of your power source match the voltage and frequency inscribed on the equipment s electrical rating label. Follow the electrostatic discharge safety practices as described in this document. Performing Electrostatic Discharge and Antistatic Prevention Measures Electrostatic Discharge Safety Measures Electrostatic discharge (ESD) sensitive devices, such as the motherboards, PCI cards, hard drives, and memory modules, require special handling. Quad-Core CPU Upgrade Kit Installation Guide 7
10 Caution Circuit boards and hard drives contain electronic components that are extremely sensitive to static electricity. Ordinary amounts of static electricity from clothing or the work environment can destroy the components located on these devices. Do not touch the components without antistatic precautions, especially along the connector edges. Caution You must disconnect the power supply before servicing any of the components documented in this chapter. Using an Antistatic Wrist Strap Wear an antistatic wrist strap and use an antistatic mat when handling components such as hard drive assemblies, circuit boards, or PCI cards. When servicing or removing server components, attach an antistatic strap to your wrist and then to a bare metal area on the chassis. Following this practice equalizes the electrical potentials between you and the server. Note An antistatic wrist strap is included in the upgrade kit. Using an Antistatic Mat Place static-sensitive components such as motherboards, memory, and other PCBs on an antistatic mat. Antistatic Handling Procedure 1. Prepare an antistatic surface to set parts on during the removal, installation, or replacement process. Place static-sensitive components such as the printed circuit boards, memory modules, and CPUs on the antistatic mat. The following items can be used as an antistatic mat: Antistatic bag used to wrap a Sun replacement part Sun antistatic mat, part number A disposable antistatic mat (shipped with some replacement parts or optional system components) 2. Attach an antistatic wrist strap. 8 Quad-Core CPU Upgrade Kit Installation Guide December 2008
11 When servicing or removing server components, attach an antistatic strap to your wrist and then to a bare metal area on the chassis. Proceed to the next section, Preparing for the Upgrade. Preparing for the Upgrade Perform the following steps: Step Task Procedure 1 Review the Sun Fire X2200 M2 Server Product Notes. Reviewing Product Note Documentation on page 9 2 Record your current BIOS settings. Recording Your Current BIOS settings on page 10 3 Prepare the server for the upgrade. Preparing the Server for the Upgrade on page 11 Reviewing Product Note Documentation The Sun Fire X2200 M2 Server Product Notes contains updated information about issues and developments for your server. Before you begin the quad-core CPU upgrade, review this document. To Review Product Note Documentation View or download the latest revision of the Sun Fire X2200 M2 Server Product Notes at: Downloading the Tools and Drivers CD To upgrade the server to quad-core CPUs you must update the firmware using the firmware available on the Sun Fire X2200 M2 Server Tools and Drivers CD v2.0 (or later). The CD is available online as an ISO image. You need to download the ISO image and burn a CD to use after you perform the hardware upgrade of your server. Quad-Core CPU Upgrade Kit Installation Guide 9
12 Note For the quad-core upgrade, the server s service processor (SP) firmware must be upgraded to the firmware level v3.15. To Download the Tools and Drivers CD 1. Download the Sun Fire X2200 M2 Server Tools and Drivers CD v2.0 (or later) ISO image at: 2. From the description of the contents of the Tools and Drivers CD, make note of the BIOS firmware version number. 3. Burn a CD using the ISO image. 4. Retain the CD for use after the server hardware upgrade. Recording Your Current BIOS settings To upgrade your dual-core server to quad-core or enhanced quad-core CPUs, you need to replace the firmware PROM, which contains the default BIOS settings. If you had previously customized the BIOS by changing the default settings, then you need to access the BIOS Setup Utility and record those changes before you begin this upgrade procedure. After the upgrade is finished, you must enter the BIOS Setup Utility again to customize the BIOS settings. Accessing the BIOS Setup Utility The method described here for accessing the BIOS Setup Utility involves attaching a keyboard, video, and mouse (KVM) to the server. You can also use the Remote Console application in the Embedded Lights Out Manager s (ELOM) web GUI and the Remote Power Control submenu to boot directly to the BIOS Setup Utility. For information about the Remote Console application, see the Sun Fire X2200 M2 Installation Guide and the Embedded Lights Out Manager Administration Guide. To Record Your Current BIOS Settings 1. Attach a KVM to the server, so that you can view the power-on self test (POST) messages. 10 Quad-Core CPU Upgrade Kit Installation Guide December 2008
13 2. Boot the server, and watch the POST messages as they appear on the display. 3. When prompted, press the F2 key to enter the BIOS Setup Utility screens. The BIOS Setup Utility screen appears. 4. Use the arrow keys to scroll through the BIOS Setup Utility screens and record your customized settings. 5. To exit the BIOS Setup Utility press the Esc key or the F10 key. Preparing the Server for the Upgrade Preparing the server for the upgrade involves placing the server in an area that provides enough space and light to allow you to perform the steps in each procedure safely and easily. To Prepare the Server for the Upgrade 1. Perform a clean shutdown of the operating system. Use the OS-specific shutdown procedure. 2. Power off the server. 3. Remove the power cable. 4. Power off and remove all peripheral devices connected to the server. 5. Label and disconnect all cables connected to the server. Use tape, color-coding, or some other scheme that will assist you in cabling the system at the end of the upgrade. 6. Remove the server from the rack. For more information, see the Sun Fire X2200 M2 Server Service Manual. 7. Place the server on a flat surface. Choose a surface with an ample amount of surrounding work space. 8. To remove the server cover, use a #2 Phillips screwdriver to loosen the two captive screws located on the rear of the server (see FIGURE 1). 9. Remove the cover and set aside. Quad-Core CPU Upgrade Kit Installation Guide 11
14 FIGURE 1 Removing the Server Cover 10. Put the anti-static wrist strap on your wrist. If necessary, connect the grounding cord to the wrist strap, and connect the other end (clip end) of the cord to bare metal on the server chassis. The strap should fit snugly enough on your wrist so that the metal contact point constantly touches bare skin. 11. Inspect the interior of the server, and, if necessary, use compressed air to remove dust from the server. Identifying Components Use the figure to identify and familiarize yourself with the components referenced in these procedures. 12 Quad-Core CPU Upgrade Kit Installation Guide December 2008
15 Figure Legend Component Locations 1 Air duct 2 PCI riser assembly 3 Firmware PROM (obscured) 4 Heatsinks/CPUs 5 System Battery (under air duct) Proceed to the next section, Removals and Replacements. Quad-Core CPU Upgrade Kit Installation Guide 13
16 Removals and Replacements Perform the following steps: Step Task Procedure 1 Remove the Air Duct and Heatsinks. Removing the Air Duct and Heatsinks on page 14 2 Remove the CPU. Removing the CPUs on page 16 3 Install the Quad-Core CPU. Installing the Quad-Core CPUs on page 18 4 Install the New Heatsink. Installing the New Heatsink on page 20 5 Remove the Firmware PROM. Replacing the Firmware PROM on page 22 6 Install the New Firmware PROM. Installing the New Firmware PROM on page 24 7 Clear the CMOS Clearing CMOS on page 25 Note Retain all packaging materials and old heatsinks and CPUs for return to Sun Microsystems, Inc. Removing the Air Duct and Heatsinks Before you can upgrade the CPUs, you must first remove the air duct and the heatsinks. The Sun Fire X2200 M2 heatsink is a passive thermal dissipation device that helps to move heat away from the CPU. The air duct provides a concentrated flow of air from the system fans to the heatsinks. The heatsinks sit atop the CPUs, and are secured to the motherboard with four screws. A thin layer of thermal compound is between the top of the CPU and the bottom of the heatsink. In addition to facilitating the transfer of heat away from the CPU to the heatsink, this compound also acts as an mild adhesive. Caution The heatsink can become hot. Allow sufficient time for cooling before handling. 14 Quad-Core CPU Upgrade Kit Installation Guide December 2008
17 To Remove the Air Duct and Heatsinks 1. Use a #1 Phillips screwdriver to remove the air duct retaining screw (see FIGURE 2). FIGURE 2 Removing the Air Duct Retaining Screw 2. Remove the air duct. Set the air duct and retaining screw aside. 3. To remove the heatsink, gently press down on the center of the heatsink, and use a #2 Phillips screwdriver to loosen the four captive screws that secure the heatsink to the motherboard (see FIGURE 3). The four captive screws are spring-loaded. Pressing down slightly on the center of the heatsink relieves the spring tension. Quad-Core CPU Upgrade Kit Installation Guide 15
18 FIGURE 3 Removing the Heatsink The heatsink assembly is also secured to the top surface of the CPU by a layer of thermal compound, which acts as an adhesive. 4. Grip the sides of the heatsink, and while pulling slightly upward, wiggle the heatsink right and left to break the adhesive seal created by the thermal compound. 5. Place the heatsink upside-down on a flat surface to prevent the thermal compound from contaminating the work area and other components. 6. Repeat Step 1 through Step 5 to remove the other heatsink. 7. Proceed to the next section, Removing the CPUs. Removing the CPUs The CPUs are secured in the socket by a CPU retaining cover. To open the CPU retaining cover, you must unlock the retaining cover release lever. The release lever is located on one side of the socket and is held in place by a clip. 16 Quad-Core CPU Upgrade Kit Installation Guide December 2008
19 To Remove the CPUs 1. Gently push down on the socket release lever, and move the lever slightly away from the CPU. This action frees the lever, which is held in place by a clip. 2. Lift the lever to the fully open position (see FIGURE 4). 3. Lift the hinged CPU retaining cover to the fully open position (see FIGURE 4). Note The top of the CPU might have a residual layer of thermal compound. FIGURE 4 Removing the CPU Quad-Core CPU Upgrade Kit Installation Guide 17
20 4. Lift the CPU out of the socket (see FIGURE 4). Leave the release lever and the CPU retaining cover in the fully open position. 5. Set the CPU aside, taking care to prevent the thermal compound from contaminating the work area and other components 6. Repeat Step 1 through Step 5 for the other CPU. 7. Proceed to the next section, Installing the Quad-Core CPUs. Installing the Quad-Core CPUs The CPU and CPU socket are keyed to assist you in proper installation. Both the CPU and the CPU socket are marked with a small triangle in one corner. Some CPU sockets might have a corner that is trimmed instead of marked with a triangle. This trimmed corner also acts as the key. When installing the CPU, align the triangle on the CPU with the triangle or trimmed corner on the CPU socket. Caution Irreparable damage to the CPU can occur through improper handling. Observe the ESD precautions when handling the CPU. Wear a securely grounded ESD wrist strap. Hold the CPU by the edges only. Do not touch the metal contacts. To Install the Quad-Core CPUs Note If you are installing a single CPU only, the CPU must be installed in socket CPU0. 1. Unpack the new quad-core CPUs from the upgrade kit. Handle the CPU with care. Do not touch the metal contacts. 2. Ensure that the socket release lever and the CPU retaining cover are in the fully open position (see FIGURE 4). 3. Align the keyed CPU corner with the keyed CPU socket corner. The CPU has a small triangle mark on one corner. The CPU socket has a similar mark on one corner. This mark is the key, indicating proper positioning of the CPU in the CPU socket (see FIGURE 5). 18 Quad-Core CPU Upgrade Kit Installation Guide December 2008
21 FIGURE 5 Installing CPU Using Triangular Key Marks Align Triangular CPU and Socket Key Marks Caution Irreparable damage to the motherboard can occur if the CPU is dropped onto the socket, if the CPU is skewed or sitting unevenly on the socket, or if the CPU is forced into the socket. Handle the CPU with care and gently place the CPU onto socket. The CPU does not need to be forcibly seated or inserted. 4. Gently place the CPU onto the CPU socket (see FIGURE 6). Do not press down on the CPU. The CPU does not need to be forcibly seated or inserted. The CPU should be lying flat on the socket. It should not be skewed or sitting unevenly. When properly positioned the CPU fits snugly in the CPU socket. Quad-Core CPU Upgrade Kit Installation Guide 19
22 FIGURE 6 Installing the CPU 5. Close the CPU retaining cover (see FIGURE 6). 6. To secure the CPU in the socket, rotate the socket release lever down until it snaps into place under the lever retaining clip. The CPU is now installed. 7. To install the other quad-core CPU, repeat Step 1 through Step Proceed to the next section, Installing the New Heatsink. Installing the New Heatsink The new heatsink has the thermal compound pre-applied. This compound is protected by a thin plastic cover, which you must remove before installing the heatsink onto the CPU. 20 Quad-Core CPU Upgrade Kit Installation Guide December 2008
23 To Install the New Heatsink 1. Remove the heatsink from the upgrade kit. 2. Remove the plastic cover that protects the thermal compound. 3. Position the heatsink over the CPU. Allow the captive screws in the heatsink to dangle, and align the screws with the screw holes on the motherboard. Caution Thermal damage to the CPU can occur if the heatsink is moved too much during installation. The layer of thermal grease might become uneven, leading to component damage. 4. Gently lower the heatsink onto the CPU. 5. To attach the heatsink to the motherboard, alternately tighten the four screws by turning each screw approximately 180 degrees (see FIGURE 7). The captive heatsink screws are spring-loaded. To counteract the springs, you might need to gently press down on the center of the heatsink while tightening the screws. 6. Continue alternately tightening the screws until all four screws are tight. Quad-Core CPU Upgrade Kit Installation Guide 21
24 FIGURE 7 Installing the Heatsink 7. To install the other heatsink, repeat Step 1 through Step Proceed to the next section, Replacing the Firmware PROM. Replacing the Firmware PROM To complete the hardware portion of the CPU upgrade, you need to replace the server s firmware PROM with the new firmware PROM that is included with the kit. Caution Irreparable damage can occur to the motherboard if you do not use a PLCC extraction tool to remove the firmware PROM. A PLCC extraction tool is included in the upgrade kit. 22 Quad-Core CPU Upgrade Kit Installation Guide December 2008
25 To Remove the Firmware PROM Note The firmware PROM is located at the rear of the server. Access to the PROM is obstructed by the PCI riser assembly. To replace the firmware PROM, you must first remove the PCI riser assembly. 1. First, remove PCI riser assembly by gripping the ends of the assembly and lifting it straight up out of the PCI slot on the motherboard (see FIGURE 8). Note If a PCI card is installed in the riser assembly, you do not need to remove the card. The firmware PROM is located toward the rear of the server (see FIGURE 8). FIGURE 8 Removing the PCI Riser and Extracting the Firmware PROM Grab here and lift. 2. Set the PCI riser assembly next to the server. 3. Insert the ends of the PLCC extraction tool into the elongated corner slots on the firmware PROM socket (see FIGURE 8). Quad-Core CPU Upgrade Kit Installation Guide 23
26 4. To remove the firmware PROM, gently squeeze the extraction tool. This action pulls the PROM from the socket. 5. Remove the PROM from the server, and proceed to the next section. Installing the New Firmware PROM The firmware PROM chip is keyed for proper installation in the PROM socket. The PROM chip has three right-angle corners. The fourth corner, on the beveled edge side of the firmware PROM chip, is trimmed at 45 degrees. One of the outer-edge corners of the PROM socket is trimmed the same way, and the same interior corner of the PROM socket has a semi-circular protrusion. This is the key to proper installation (see FIGURE 9). To install the firmware PROM chip properly, the trimmed corner of the chip must align with the corner of the PROM socket with the semicircular protrusion. Caution Irreparable damage to the firmware PROM chip can occur through improper handling. Observe the ESD precautions when handling the firmware PROM chip. Wear a securely grounded ESD wrist strap. Hold the firmware PROM chip by the edges only. Do not touch the metal contacts. To Install the New Firmware PROM 1. Remove the new 1 Mbyte firmware PROM chip from the upgrade kit. Handle the chip carefully. Avoid touching the metal contacts. 2. Align the trimmed corner of the PROM chip with the keyed corner of the socket. The trimmed corner of the chip, when properly seated in the socket, must align with the socket corner that has the rounded protrusion (see FIGURE 9). 24 Quad-Core CPU Upgrade Kit Installation Guide December 2008
27 FIGURE 9 Socket and PROM Chip Alignment Key Socket and Chip Keys PROM Socket Firmware PROM Chip 3. When properly aligned, place the PROM chip on top of the socket. The chip should lie flat. 4. Using your finger or thumb, gently push the firmware PROM chip downward into the socket until the top of the chip is flush with the top of the socket. The new firmware PROM chip is now installed. 5. Proceed to the next section, Clearing CMOS. Clearing CMOS After replacing the firmware PROM, you need to clear the CMOS before you update the firmware. You clear the CMOS by removing the system battery and shorting the battery terminals for 60 seconds. To Clear CMOS 1. Remove the system battery by pulling it up and out of the holder (see FIGURE 10). The battery is secured in the battery holder by a metal clip that contacts the positive ( + ) side of the battery. The opposite side of the battery, the negative side, presses against a metal contact point in the base of the battery holder. When Quad-Core CPU Upgrade Kit Installation Guide 25
28 the battery is removed the metal clip and the contact point do not touch. To clear CMOS, you must make the clip and the contact point in the battery holder touch (short) for a period of 60 seconds. FIGURE 10 Removing System Battery and Clearing CMOS 2. Press the metal clip on the battery holder inward until it touches (shorts) the metal contact point in the base of the battery holder (see FIGURE 10). You can use your thumb and finger to press (squeeze) the clip against the contact point. 3. Continue shorting the clip and the contact point for a period of 60 seconds. The two points must touch (short) for 60 seconds. 4. After 60 seconds, install the battery, making certain that the positive ( + ) side of the battery faces outward (see FIGURE 10) and contacts the metal clip. 5. Install the PCI riser assembly. 26 Quad-Core CPU Upgrade Kit Installation Guide December 2008
29 6. Install the air duct, and secure it with the air duct retaining screw. 7. Proceed to the next section, Preparing for Operation. Preparing for Operation Perform the following steps: Step Task Procedure 1 Prepare the server for operation. Preparing the Server for Operation on page 27 2 Update SP firmware. Updating the SP Firmware on page 28 3 Update BIOS firmware Updating BIOS Firmware on page 29 4 Perform power-on and BIOS setup procedures. Performing Power On and BIOS Setup Procedures on page 30 Preparing the Server for Operation Perform the following procedures to prepare the upgraded server for operation. To Prepare the Server for Operation 1. Inspect the interior of the server, ensuring that all cables are properly routed and all components are properly seated. 2. Remove any tools. 3. Install the server top cover. 4. Retain the kit packaging material, old heatsinks, and old CPUs. You can return these items to Sun Microsystems. 5. Install the server in the rack, and plug in the power cable. Quad-Core CPU Upgrade Kit Installation Guide 27
30 Updating the SP Firmware Before you can use the server, you must upgrade the SP and BIOS firmware. You upgrade the server firmware using the Sun Fire X2200 M2 Server Tools and Drivers CD that you created at the beginning of the upgrade procedure. To Update the SP Firmware 1. Attach a KVM to the server, so that you can view the Tools and Drivers boot menu. 2. Power on the server and insert the Tools and Drivers CD v2.0 (or later) into the server s CD/DVD drive. The system boots from the CD and the Tools and Drivers CD main menu appears. If error 410E occurs and the system stops booting, do the following: a. Press F1 A Load Defaults prompt message appears. b. When prompted, press F2 to load defaults. The defaults load, the server reboots, and the Tools and Drivers main menu appears. 3. From the Tools and Drivers main menu, select option #4, Exit to DOS. The DOS prompt appears: C:\> 4. At the DOS prompt navigate to the \flash\sp\latest directory by entering the following command: C:\> cd \flash\sp\latest The DOS Prompt appears: C:\flash\sp\latest> 5. At the prompt list the contents of the \flash\sp\latest directory by executing the dir command: C:\flash\sp\latest> dir The contents of the directory appears. 28 Quad-Core CPU Upgrade Kit Installation Guide December 2008
31 6. Review the contents of the directory, and make note of the name of the s39uversion.bin file. Where version is the version number of the SP firmware. For example: s39u315.bin 7. To update the firmware enter the following command: C:\flash\sp\latest> download.exe -f s39uversion.bin For example: C:\flash\sp\latest> download.exe -f s39u315.bin The update script verifies the PROM size before starting the update. The following warning message might appear: Warning: The system contains 512k BIOS flash ROM. The BIOS only supports AMD Dual-Core processors. If the above message appears, you do not have the 1 Mbyte PROM installed in the server. To complete the quad-core upgrade you must install the 1 Mbyte PROM that came with the Quad-Core Upgrade Kit. To replace the PROM, see Replacing the Firmware PROM on page 22. The SP update process takes about two minutes to finish. 8. When the firmware update process ends, the server reboots. 9. Do the following depending upon the type of upgrade you are performing: For a dual-core CPU to quad-core CPU upgrade: Go to the next section, Updating BIOS Firmware on page 29. For a quad-core CPU to enhanced quad-core CPU upgrade: Go to the section, Performing Power On and BIOS Setup Procedures on page 30. Updating BIOS Firmware The firmware version preflashed onto the upgrade kit PROM chip might not be the latest version. When the server is operational verify the firmware version, and if necessary, update the PROM. During the update process the following error message appears if you are attempting to update the PROM with the wrong file: ERROR: File size does not match ROM size! Use the correct file or upgrade ROM. Quad-Core CPU Upgrade Kit Installation Guide 29
32 If this message occurs during the update process, update the PROM with the correct file. To Update BIOS Firmware 1. Use the ELOM web GUI or the command-line interface (CLI) to check the server s BIOS version. See the Sun Fire X2200 M2 Server Embedded Lights Out Manager Administrative Guide for instructions about using the web GUI or the CLI to view BIOS and SP version numbers. 2. Compare the BIOS version number of the server to the version number, that you noted in Downloading the Tools and Drivers CD on page If the server BIOS firmware does not match the version on the Tools and Drivers CD, use the ELOM web GUI or the CLI to update the firmware PROM. If the version numbers match, then proceed to the next section, Performing Power On and BIOS Setup Procedures on page 30. See the Sun Fire X2200 M2 Server Embedded Lights Out Manager Administrative Guide for instructions on updating the BIOS and SP firmware. 4. Proceed to the next section, Performing Power On and BIOS Setup Procedures on page 30. Performing Power On and BIOS Setup Procedures You must access the BIOS Setup Utility and load default settings. You can then customize the BIOS settings, returning the server to the settings you retained in Recording Your Current BIOS settings on page 10. To Perform Power On and BIOS Setup Procedures 1. Attach a KVM to the server, so that you can view the power-on self test (POST) messages. 2. Boot the server, and watch the POST messages as they appear on the display. 3. When prompted, press the F2 key to enter the BIOS Setup Utility. The BIOS Setup Utility screen appears. 30 Quad-Core CPU Upgrade Kit Installation Guide December 2008
33 4. Load default settings, and Save and Exit the BIOS. 5. If you need to customize the BIOS settings, repeat Step 1 through Step 3 and enter the settings you saved in Recording Your Current BIOS settings on page After customizing the BIOS settings, Save and Exit the BIOS Setup Utility. The server boots and is ready for operation. 7. Proceed to the next section, Returning Parts to Sun Microsystems. Returning Parts to Sun Microsystems The final step in the quad-core upgrade procedure is to return the old heatsinks and CPUs to Sun Microsystems using the SunReturns trade-in program. For information on SunReturns and trade-ins, go to: Quad-Core CPU Upgrade Kit Installation Guide 31
34 32 Quad-Core CPU Upgrade Kit Installation Guide December 2008
Sun Cobalt Control Station. Using the LCD Console
Sun Cobalt Control Station Using the LCD Console Copyright 1997-2001 Sun Microsystems, Inc., 901 San Antonio Road, Palo Alto, California 94303-4900 U.S.A. All rights reserved. Sun Microsystems, Inc. has
Sun Blade 100 CD-ROM or DVD-ROM and Hard Disk Drive Installation Guide
Sun Blade 100 CD-ROM or DVD-ROM and Hard Disk Drive Installation Guide Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 806-6637-12 January 2002, Revision A
Sun Management Center Change Manager 1.0.1 Release Notes
Sun Management Center Change Manager 1.0.1 Release Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 817 0891 10 May 2003 Copyright 2003 Sun Microsystems, Inc. 4150
Sun Blade 150 CD-ROM, DVD-ROM, and Hard Drive Installation Guide
Sun Blade 150 CD-ROM, DVD-ROM, and Hard Drive Installation Guide Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 816-5369-10 June 2002, Revision A Send comments
Sun Management Center 3.6 Version 5 Add-On Software Release Notes
Sun Management Center 3.6 Version 5 Add-On Software Release Notes For Sun Fire, Sun Blade, Netra, and Sun Ultra Systems Sun Microsystems, Inc. www.sun.com Part No. 819-7977-10 October 2006, Revision A
Solaris 10 Documentation README
Solaris 10 Documentation README Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 817 0550 10 January 2005 Copyright 2005 Sun Microsystems, Inc. 4150 Network Circle, Santa
Sun TM SNMP Management Agent Release Notes, Version 1.6
Sun TM SNMP Management Agent Release Notes, Version 1.6 Sun Microsystems, Inc. www.sun.com Part No. 820-5966-12 December 2008, Revision A Submit comments about this document by clicking the Feedback[+]
Sun Management Center 3.6 Version 4 Add-On Software Release Notes
Sun Management Center 3.6 Version 4 Add-On Software Release Notes For Sun Fire, Sun Blade, Netra, and Sun Ultra Systems Sun Microsystems, Inc. www.sun.com Part No. 819-4989-10 July 2006, Revision A Submit
Sun Ray, Smart Cards, and Citrix
Sun Ray, Smart Cards, and Citrix Enabling Sun Ray Smart Card Pass-through to Citrix Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 May 2004, Version 1.0 Copyright
Sun Fire V20z and Sun Fire V40z Servers Differences Between Server Versions
Sun Fire V20z and Sun Fire V40z Servers Differences Between Server Versions This document compares the released versions of the Sun Fire V20z and Sun Fire V40z servers. This document includes the following
Sun SNMP Management Agent Release Notes, Version 1.5.5
Sun SNMP Management Agent Release Notes, Version 1.5.5 Sun Microsystems, Inc. www.sun.com Part No. 820-0174-15 June 2008, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback
SunFDDI 6.0 on the Sun Enterprise 10000 Server
SunFDDI 6.0 on the Sun Enterprise 10000 Server Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No.: 806-3610-11 November 1999, Revision A Send
Sun Enterprise Optional Power Sequencer Installation Guide
Sun Enterprise Optional Power Sequencer Installation Guide For the Sun Enterprise 6500/5500 System Cabinet and the Sun Enterprise 68-inch Expansion Cabinet Sun Microsystems, Inc. 901 San Antonio Road Palo
N1 Grid Service Provisioning System 5.0 User s Guide for the Linux Plug-In
N1 Grid Service Provisioning System 5.0 User s Guide for the Linux Plug-In Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 819 0735 December 2004 Copyright 2004 Sun Microsystems,
Sun Fire V20z Server Release Notes
Sun Fire V20z Server Release Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 817-5252-10 March, 2004 Revison A Submit comments about this document at:
Sun StorEdge A5000 Installation Guide
Sun StorEdge A5000 Installation Guide for Windows NT Server 4.0 Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No. 805-7273-11 October 1998,
Solaris 9 9/05 Installation Roadmap
Solaris 9 9/05 Installation Roadmap This document is a guide to the DVD-ROM, CD-ROMs, and documents involved in installing the Solaris 9 9/05 software. Unless otherwise specified, this document refers
Sun StorEdge Availability Suite Software Point-in-Time Copy Software Maximizing Backup Performance
Sun StorEdge Availability Suite Software Point-in-Time Copy Software Maximizing Backup Performance A Best Practice Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part
Sun Management Center 3.5 Update 1b Release Notes
Sun Management Center 3.5 Update 1b Release Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 819 3054 10 June 2005 Copyright 2005 Sun Microsystems, Inc. 4150 Network
Sun StorEdge Enterprise Backup Software 7.2
Sun StorEdge Enterprise Backup Software 7.2 Update Guide Sun Microsystems, Inc. www.sun.com Part No. 819-4089-10 September 2005, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Sun StorEdge RAID Manager 6.2.21 Release Notes
Sun StorEdge RAID Manager 6.2.21 Release Notes formicrosoftwindowsnt Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No. 805-6890-11 November
RAID Controller PCI Card for the Sun Fire V60x and V65x Servers Release Notes
RAID Controller PCI Card for the Sun Fire V60x and V65x Servers Release Notes CAUTION: Read this document before installing the RAID Controller PCI Card. Failure to use the correct firmware version with
Distributed Application Management using Jini Connection Technology
Distributed Application Management using Jini Connection Technology The Jini Technology Enabled Applications Manager provides a framework, utilizing Jini and JavaSpaces technologies, for selecting and
Solaris Resource Manager
Solaris Resource Manager By Richard McDougall - Enterprise Engineering Sun BluePrints OnLine - April 1999 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 USA
Sun StorEdge network FC switch-8 and switch-16 Release Notes
Sun StorEdge network FC switch-8 and switch-16 Release Notes Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 806-6924-14 February 2001, Revision A Send
A Strategy for Managing Performance
A Strategy for Managing Performance John Brady, Sun Professional Services Sun BluePrints OnLine December 2002 http://www.sun.com/blueprints Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95045
Upgrading the Solaris PC NetLink Software
Upgrading the Solaris PC NetLink Software By Don DeVitt - Enterprise Engineering Sun BluePrints OnLine - January 2000 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road Palo Alto,
Optimizing Solaris Resources Through Load Balancing
Optimizing Solaris Resources Through Load Balancing By Tom Bialaski - Enterprise Engineering Sun BluePrints Online - June 1999 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road
Sun Grid Engine 5.2.3 Release Notes
Sun Grid Engine 5.2.3 Release Notes Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 816-2082-10 July 2001 For more information, go to http://www.sun.com/gridware
Service Level Definitions and Interactions
Service Level Definitions and Interactions By Adrian Cockcroft - Enterprise Engineering Sun BluePrints OnLine - April 1999 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road Palo
Sun Enterprise 420R Server Product Notes
Sun Enterprise 420R Server Product Notes Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No. 806-1082-12 May 2001, Revision A Send comments about
Sun Fire B10n Content Load Balancing Blade Product Notes
Sun Fire B10n Content Load Balancing Blade Product Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 817-0628-10 June 2003, Revision A Submit comments
Sun Cluster 2.2 7/00 Data Services Update: Apache Web Server
Sun Cluster 2.2 7/00 Data Services Update: Apache Web Server Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 806-6121 July 2000, Revision A Copyright 2000
Sun Fire V210 and V240 Servers Parts Replacement Manual
Sun Fire V210 and V240 Servers Parts Replacement Manual Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 817-0743-10 January 2003, Revision A Send comments
Sun Ultra TM. 5 and Ultra 10 Product Notes. Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A.
Sun Ultra TM 5 and Ultra 10 Product Notes Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 806-6750-11 November 2000, Revision A Send comments about this
Using Linux mdadm Multipathing with Sun StorEdge Systems
Using Linux mdadm Multipathing with Sun StorEdge Systems Sun Microsystems, Inc. www.sun.com Part No. 819-2452-10 April 2005, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Sun StorEdge Network FC Switch-8 and Switch-16 Release Notes
Sun StorEdge Network FC Switch-8 and Switch-16 Release Notes Sun StorEdge SAN 3.0 Release Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 816-0842-12 February
Scrubbing Disks Using the Solaris Operating Environment Format Program
Scrubbing Disks Using the Solaris Operating Environment Format Program By Rob Snevely - Enterprise Technology Center Sun BluePrints OnLine - June 2000 http://www.sun.com/blueprints Sun Microsystems, Inc.
Sharing NFS and Remote File Systems via Solaris PC NetLink Software
Sharing NFS and Remote File Systems via Solaris PC NetLink Software By Don DeVitt - Enterprise Engineering Sun BluePrints OnLine - November 2000 http://www.sun.com/blueprints Sun Microsystems, Inc. 901
SPARC Enterprise T5140 and T5240 Servers. StorageTek SAS RAID Eight-Port Internal HBA Installation Guide
SPARC Enterprise T5140 and T5240 Servers StorageTek SAS RAID Eight-Port Internal HBA Installation Guide Part No. 820-4754-12 Manual Code: C120-E521-03XA August 2010 Copyright 2008, 2010, Oracle and/or
Sun Fire 6800/4810/4800/3800 Systems Firmware 5.13.3 Release Notes
Sun Fire 6800/4810/4800/3800 Systems Firmware 5.13.3 Release Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 816-7909-10(v2) October 2002, Revision A
Sun Ray Connector for Windows OS, Version 2.1 Release Notes
Sun Ray Connector for Windows OS, Version 2.1 Release Notes Sun Microsystems, Inc. www.sun.com Part No.820-3777-12 October 2008, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback
SCSI Sense Key Error Guide
SCSI Sense Key Error Guide Sun Microsystems, Inc. www.sun.com Part No. 817-5918-10 February 2004, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback Copyright 2004 Sun
Sun SM Remote Services Net Connect Solaris TM 9 4/04
Sun SM Remote Services Net Connect Solaris TM 9 4/04 Installation and Activation Guide Sun Microsystems, Inc. www.sun.com Part No. 916-1586 Revision 1.0 May 25, 2004 Submit comments about this document
Sun StorEdge N8400 Filer Release Notes
Sun StorEdge N8400 Filer Release Notes Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 U.S.A. 650-960-1300 Part No. 806-6888-10 February 2001, Revision A Send comments about this document
Power Savings in the UltraSPARC T1 Processor
Power Savings in the UltraSPARC T1 Processor David Greenhill, Distinguished Engineer Jerome Alabado, Staff Engineer Sun Microsystems Inc. December 2005 Sun Microsystems, Inc. 4150 Network Circle Santa
Service Guide. Gateway M275
Service Guide Gateway M275 Contents Replacing Gateway M275 Components.................................... 1 Identifying the convertible tablet PC model...................................... 2 Identifying
Service Level Agreement in the Data Center
Service Level Agreement in the Data Center By Edward Wustenhoff Sun Professional Services Sun BluePrints OnLine - April 2002 http://www.sun.com/blueprints Sun Microsystems, Inc. 4150 Network Circle Santa
Java Device Test Suite Local Relay User s Guide
Java Device Test Suite Local Relay User s Guide Version 2.4 Java ME Platform Sun Microsystems, Inc. www.sun.com May 2009 Submit comments about this document by clicking the Feedback[+] link at: http://docs.sun.com
Netra X4200 M2 Server Site Planning Guide
Netra X4200 M2 Server Site Planning Guide Sun Microsystems, Inc. www.sun.com Part No. 820-0069-12 May 2008, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback Copyright
Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
Netra Data Plane Software Suite 2.0 Update 2 Release Notes
Netra Data Plane Software Suite 2.0 Update 2 Release Notes Sun Microsystems, Inc. www.sun.com Part No. 820-5213-11 July 2008, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Solaris 9 Installation Roadmap
Solaris 9 Installation Roadmap This document is a guide to the DVD, CDs and documents involved in installing the Solaris 9 software. Unless otherwise specified, this document refers to both DVDs and CDs
Brocade SilkWorm 4100 FC Switch Release Notes
Brocade SilkWorm 4100 FC Switch Release Notes For Installation in Sun Storage Area Networks, 4.4.0b Firmware Sun Microsystems, Inc. www.sun.com Part No. 819-1672-10 April 2005, Revision A Submit comments
Comparing JavaServer Pages Technology and Microsoft Active Server Pages
Comparing JavaServer Pages Technology and Microsoft Active Server Pages An Analysis of Functionality Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 1 (800) 786.7638 1.512.434.1511 Copyright
Rapid Recovery Techniques: Auditing Custom Software Configuration
Rapid Recovery Techniques: Auditing Custom Software Configuration By Richard Elling - Enterprise Engineering Sun BluePrints OnLine - February 2000 http://www.sun.com/blueprints Sun Microsystems, Inc. 901
Sun StorEdge T3 Dual Storage Array - Part 1
Sun StorEdge T3 Dual Storage Array - Part 1 Installation, Planning, and Design By Mark Garner - Enterprise Engineering Sun BluePrints OnLine - February 2001 http://www.sun.com/blueprints Sun Microsystems,
Start Here. Installation and Documentation Reference. Sun StorEdgeTM 6120 Array
Start Here Installation and Documentation Reference Sun StorEdgeTM 6120 Array 1 Access the Online Documentation These documents and other related documents are available online at http://www.sun.com/documentation
Sun Ray Server Software 4.0 Release Notes
Sun Ray Server Software 4.0 Release Notes for the Linux Operating System Sun Microsystems, Inc. www.sun.com Part No. 820-0418-11 April 2008, Revision A Copyright 2002 2008, Sun Microsystems, Inc., 4150
SUN SEEBEYOND egate INTEGRATOR RELEASE NOTES. Release 5.1.1
SUN SEEBEYOND egate INTEGRATOR RELEASE NOTES Release 5.1.1 Copyright 2006 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun Microsystems, Inc.
SERVICE GUIDE. Gateway Notebook
SERVICE GUIDE Gateway Notebook Contents Replacing Gateway Notebook Components...................................1 Identifying the notebook model......................................... 2 Identifying
Solaris Bandwidth Manager
Solaris Bandwidth Manager By Evert Hoogendoorn - Enterprise Engineering Sun BluePrints Online - June 1999 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 USA
Brocade 5300 Switch Hardware Release Notes
Brocade 5300 Switch Hardware Release tes For Installation in a Sun Storage Area Network Sun Microsystems, Inc. www.sun.com Part. 820-4925-10 May 2008, Revision A Submit comments about this document at:
Sun Fire V480 Server Product Notes
Sun Fire V480 Server Product Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 816-0905-14 September 2002, Revision A Send comments about this document
LAN-Free Backups Using the Sun StorEdge Instant Image 3.0 Software
LAN-Free Backups Using the Sun StorEdge Instant Image 3.0 Software Art Licht, Sun Microsystems, Inc. Sun BluePrints OnLine June 2002 http://www.sun.com/blueprints Sun Microsystems, Inc. 4150 Network Circle
Kurzweil KORE 64. ROM Expansion Board for the PC3 and PC3K
Kurzweil KORE 64 ROM Expansion Board for the PC3 and PC3K Installation Instructions August 1, 2012 2012 Young Chang Co., Ltd. All rights reserved. Kurzweil is a product line of Young Chang Co., Ltd. Kurzweil,
Sun N1 Service Provisioning System User s Guide for Linux Plug-In 2.0
Sun N1 Service Provisioning System User s Guide for Linux Plug-In 2.0 Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 819 4885 10 April 2006 Copyright 2006 Sun Microsystems,
JumpStart : NIS and sysidcfg
JumpStart : NIS and sysidcfg By Rob Snevely - Enterprise Technology Center Sun BluePrints OnLine - October 1999 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303
Exploring the iplanet Directory Server NIS Extensions
Exploring the iplanet Directory Server NIS Extensions By Tom Bialaski - Enterprise Engineering Sun BluePrints OnLine - August 2000 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road
Data Center Design Philosophy
Data Center Design Philosophy By Rob Snevely - Enterprise Technology Center Sun BluePrints OnLine - January 2002 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA
Sun 450 MHz UltraSPARC -II Module Upgrade
Sun 450 MHz UltraSPARC -II Module Upgrade Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No.: 806-1055-11 Revision A, October 1999 Send comments
Compaq Presario Desktop Products. Upgrading and Servicing Guide
Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to
Sun StorEdge SAN Foundation Release Notes
Sun StorEdge SAN Foundation Release Notes Version 4.1 Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 817-0071-10 October 2002, Revision 01 Send comments about
HP ProLiant DL165 G7 Server. Installation Instructions
HP ProLiant DL165 G7 Server Installation Instructions Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 HDD Item 1 Thumbscrews for rack mounting 2 Drive status
EasyNote TJ Series. Disassembly Manual
EasyNote TJ Series Disassembly Manual CHAPTER3 Replacing notebook components Preventing static electricity discharge Preparing the work space Required tools Preparing the notebook Adding or replacing memory
Sun Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Fire X4150, X4250 and X4450 Servers
Sun Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Fire X4150, X4250 and X4450 Servers Sun Microsystems, Inc. www.sun.com Part No. 820-7842-11 November 2009, Revision A Submit comments
Java Dynamic Management Architecture for Intelligent Networks
Java Dynamic Management Architecture for Intelligent Networks Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 1 (800) 786.7638 +1.512.434.1511 Copyright 1998 Sun Microsystems, Inc., 901
Brocade 300 Switch Hardware Release Notes
300 Switch Hardware Release Notes For Installation in a Sun Storage Area Network Sun Microsystems, Inc. www.sun.com Part No. 820-4923-11 November 2008, Revision A Submit comments about this document at:
HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in
HP Pavilion All-in-One MS200 series PC *579907-001* *579907-001* Printed in Upgrading and Servicing Guide Replacing a Wireless Keyboard or Mouse...2 Before You Begin... 2 Replacing the Keyboard or Mouse...
Sun Fire V480 Server Setup and Rackmounting Guide
Sun Fire V480 Server Setup and Rackmounting Guide Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 816-0902-10 February 2002, Revision A Send comments about
Dell Inspiron 660s Owner s Manual
Dell Inspiron 660s Owner s Manual Computer model: Inspiron 660s Regulatory model: D06S Regulatory type: D06S001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you
Installation Guide. Wyse C Class Conversion to WES7. Wyse USB Firmware Tool TM Release 1.10. Issue: 102910 PN: 883887-17L Rev. B
Installation Guide Wyse C Class Conversion to WES7 Wyse USB Firmware Tool TM Release 1.10 Issue: 102910 PN: 883887-17L Rev. B Copyright Notices 2010, Wyse Technology Inc. All rights reserved. This manual
Veritas Storage Foundation 5.0 Software for SPARC
Veritas Storage Foundation 5.0 Software for SPARC Release Note Supplement Sun Microsystems, Inc. www.sun.com Part No. 819-7074-10 July 2006 Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Reducing the Backup Window With Sun StorEdge Instant Image Software
Reducing the Backup Window With Sun StorEdge Instant Image Software Selim Daoud, Sun Professional Services, Switzerland Sun BluePrints OnLine July 2002 http://www.sun.com/blueprints Sun Microsystems, Inc.
UPGRADING AND SERVICING GUIDE
UPGRADING AND SERVICING GUIDE HPTouchSmart 610 PC Computer features may vary by model. Removing and Replacing a CD/DVD Drive...2 Removing the CD/DVD Drive... 2 Installing a New CD/DVD Drive... 5 Removing
Operations Management Capabilities Model
Operations Capabilities Model Edward Wustenhoff, Sun Global Datacenter Practice, Client Solutions Michael J. Moore, Sun Global Datacenter Practice, Client Solutions Dale H. Avery, Sun Educational Services
Sun Fire E2900 System Service Manual
Sun Fire E2900 System Service Manual Sun Microsystems, Inc. www.sun.com Part No. 817-4054-15 May 2006, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback Copyright 2006
Getting StartedWith Sun Java System Application Server 9.1 Update 2
Getting StartedWith Sun Java System Application Server 9.1 Update 2 Student Guide Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. August 2008 Copyright 2008 Sun Microsystems, Inc.
Sun GlassFish Mobility Platform 1.1 Deployment Guide
Sun GlassFish Mobility Platform 1.1 Deployment Guide Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 820 7205 February 2009 Copyright 2009 Sun Microsystems, Inc. 4150 Network
Managing NFS Workloads
Managing NFS Workloads By Richard McDougall, Adrian Cockcroft and Evert Hoogendoorn - Enterprise Engineering Sun BluePrints OnLine - April 1999 http://www.sun.com/blueprints Sun Microsystems, Inc. 901
Sun Blade 100 and Sun Blade 150 Workstations
Sun Blade 100 and Sun Blade 150 Workstations Differences Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 990-1211-10 June 2002, Revision 01 Send comments about
StorTrends 3400 Hardware Guide for Onsite Support
StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200
Disaster Recovery Requirements Analysis
Disaster Recovery Requirements Analysis By Stan Stringfellow - Special to Sun BluePrints OnLine Sun BluePrints OnLine - July 2000 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road
Inspiron 15. Service Manual. 3000 Series
Inspiron 15 3000 Series Service Manual Computer Model: Inspiron 15 3541/Inspiron 15 3542/Inspiron 15 3543 Regulatory Model: P40F Regulatory Type: P40F001/P40F002 Notes, Cautions, and Warnings NOTE: A NOTE
