i5000 Utility Locating System 1 with Sheath Fault Locating Option
|
|
|
- Florence Harris
- 9 years ago
- Views:
Transcription
1 i5000 Utility Locating System 1 with Sheath Fault Locating Option OPERATIONS MANUAL SERVICE CENTER, SALES AND TECHNICAL SUPPORT INFORMATION Vivax-Metrotech Corporation 3251 Olcott Street, Santa Clara, CA 95054, USA Website : Sales & Sales Support: T/Free : Tel : Fax : [email protected] Application Support: T/Free : Tel : Fax : [email protected] Service & Repairs: T/Free : Tel : Fax : [email protected] All Other Department: T/Free : Tel : Fax : Canada Vivax Canada Inc. 400 Esna Park Drive, Unit 17, Markham, Ontario, L3R 3K2, Canada Tel : Website : [email protected] Europe SebaKMT Seba Dynatronic Mess-und Ortungstechnik GmbH Dr.-Herbert-Iann-Str. 6, Baunach, Germany. Tel : Fax : Website : [email protected] Australasia SebaKMT AUS Unit 1, 176 South Creek Road, Cromer NSW 2009, Australia Tel : Fax : Website : [email protected] [email protected] China Leidi Utility Supply (Shanghai) Ltd. Rm405 3rd Building No. 641, Tianshan Rd, Shanghai, China Tel : Fax : Website : [email protected] Warranty: One year. Specifications Subject to change without notice, ISO 9001:2000 Certified. Copyright All Rights Reserved. Rev B 2/18/07
2 2 ISO 9001 CERTIFIED Metrotech has received ISO 9001:2000 Quality Management System Certification. Metrotech adheres to the quality standard guidelines of ISO 9001:2000 and ensures quality in its design/development, production, installation, and servicing disciplines. Metrotech Corporation 2008 Metrotech Corporation 3251 Olcott Street Santa Clara, CA USA Tel: ; Fax: Internet: Revision B : 2/18/2007
3 3 TABLE OF CONTENTS 1 INTRODUCTION GENERAL INFORMATION AND SAFETY SAFETY PRECAUTIONS i5000 SFL-2 SHEATH FAULT LOCATOR QUICK START GUIDE FOR THE EXPERIENCED USER SFL-2 A-FRAME RECEIVER TECHNICAL SPECIFICATIONS LOG A-FRAMES FOR POWER UTILITIES: LINEAR A-FRAMES FOR TELECOM UTILITIES: TECHNICAL DATA A-FRAME RECEIVER CONTROLS AND INDICATORS ADDITIONAL A-FRAME RECEIVER FEATURES Battery Access Plate Conductive Pads PRINCIPLES OF OPERATION FUNCTIONAL THEORY Earth Voltage Gradient Equipotentials Multiple Fault Patterns Distortion Due to Adjacent Conductors Calibration Test Procedure OPERATION CHECK THE BATTERIES PRIOR TO GOING INTO THE FIELD ENSURE ALL CONDUCTORS IN THE FIELD ARE DE-ENERGIZED LIFT THE GROUNDS ATTACH THE TRANSMITTER TO THE CONDUCTOR AND CHECK THE FAULT RESISTANCE SYNCHRONIZE THE A-FRAME RECEIVER CONFIRM THAT A FAULT EXISTS TRACE THE CABLE WITH THE I5000 RECEIVER PINPOINT THE FAULT VERIFY THE FAULT ADVANCED TECHNIQUES FAULTS UNDER INACCESSIBLE SURFACES Perpendicular Method Triangulation Method FAULTS UNDER PAVEMENT LONG DISTANCE TRACING HIGH AND LOW IMPEDANCE FAULTS MULTIPLE FAULTS MAINTENANCE RECEIVER BATTERY REPLACEMENT SERVICE CENTERS... 32
4 4 10 APPENDIX COPYRIGHT NOTICE WARRANTY...35
5 5 LIST OF ILLUSTRATIONS Figure 3-1: Clamping Black Lead to Ground Rod; Clamping Red Lead to Conductor... 9 Figure 3-2: Transmitter display in SFL mode Figure 3-3: Positioning of A-Frame Receiver for Synchronization Figure 3-4 : Locating the Cable Fault with A-Frame Receiver Figure 4-1: A-Frame Controls and Indicators Figure 5-1: Typical SFL-2 Transmitter Connection Figure 5-2: Signal Pattern Around Fault and Ground Point Figure 5-3: Multiple Fault Signal Patterns Figure 6-1: Checkout Test Set-Up Figure 7-1: Synchronizing The A-frame Figure 7-2: Fault Confirmation Figure 8-1: Perpendicular Method Figure 8-2: Triangulation Method Figure 8-3: Locating an Equipotential Circle Figure 8-4: Fault Location Using Extension Cable for Increased Sensitivity Figure 9-1: Receiver Battery Replacement... 31
6 6 1 INTRODUCTION The Metrotech i5000 TM Utility Locator with Sheath Fault Locating (SFL) option is designed to detect and pinpoint sheath and other conductor faults that are in direct contact with the earth. The i5000 SFL-2 offers these unique features: Fault level measurement at the transmitter Simultaneous fault finding and line tracing LCD bar graph representing the A-Frame signal strength for judging the proximity to faults, comparing multiple faults, and detecting pinholes and trees in a power cable Detection of low and high resistance faults Automatic battery checking and low battery warning Non-polarized A-Frame Single-handed operation. No need to carry an i5000 receiver as well as an A-frame during fault locating Active SFL ohmmeter and voltmeter in the Transmitter Operation of the unit is completely automatic. No operator adjustments are required. Both the Transmitter and Receiver are water resistant and built to withstand the rigors of field use.
7 7 2 GENERAL INFORMATION AND SAFETY This manual contains basic advice for the installation and operation of Metrotech Utility Line and Sheath Fault Locators as well as accompanying accessories. The manufacturer is not liable for damage to material or humans due to non-observance of the instructions and safety advice provided in this manual. Therefore, this manual should be provided and reviewed by all personnel associated with the line and sheath fault locating equipment. Symbols used in this manual Important instructions concerning the protection of staff and equipment as well as technical safety within this document are labeled with one of the following symbols: Symbol WARNING CAUTION Description Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury or material damage. Notes have important information and useful tips on the operation of your equipment. Nonobservance may result in incorrect measurement results. Operating personnel Repair and maintenance Metrotech utility line and sheath fault locators are intended for use by utility and contractor professionals. Repairs and service must only be done by Metrotech Corporation or authorized service departments of Metrotech Corporation. 2.1 SAFETY PRECAUTIONS Observed safety practices Familiarize yourself with all required safety practices of the local utility company, or other owner of the plant before entering an access area, or connecting a Metrotech transmitter. Ensure that the line is de-energized and out of service, BEFORE connecting the transmitter directly to any conductor. NEVER make a direct connection to a live power cable. Follow the appropriate safety procedures to avoid the risk of injury if using a clamp on energized electrical or control lines.
8 8 Pay special attention when using a locator in high traffic areas. Intended application Safe operation is only realized when using the equipment for its intended purpose. Using the equipment for other purposes may lead to human danger and equipment damage. The limits described under the technical data section may not be exceeded. Fire fighting in electrical installations: Recommended extinguishing agent: carbon dioxide (CO 2 ) Carbon dioxide is electrically non conductive and does not leave residue. It is safe to use in energized facilities as long as the minimum distances are observed. It is essential to observe the safety instruction on the extinguishing agent. WARNING Dangers when operating with High Voltage (HV): Special safety attention is needed when operating HV facilities, especially non-stationary equipment. The regulations VDE 0104 about setting up and operation of electric test equipment, i.e. the corresponding EN as well as country-specific regulations and standards must be observed. Safety installations may not be by-passed nor deactivated. Operation requires a minimum two people whereas the second person must be able to activate the emergency switch in case of danger. To avoid hazardous electric charges of metallic parts in the vicinity, all metallic parts must be grounded. To avoid drawing dangerous arcs, switching should only be done in a de-energized condition. The equipment and all accessories must be connected according to applicable standards VDE, EN or DIN as well as country-specific regulations.
9 9 3 i5000 SFL-2 SHEATH FAULT LOCATOR QUICK START GUIDE FOR THE EXPERIENCED USER 1 Check Batteries Prior to Departing for the Field Check the battery level in the Transmitter, Receiver, and A-Frame by powering up each instrument. Maximum use of the Transmitter s SFL feature requires that the battery be fully-charged prior to field use. Metrotech recommends charging the battery to full capacity before locating faults. Replace/recharge if necessary. Turn the instruments OFF. 2 Ensure All Conductors Are De-Energized 3 Lift Grounds WARNING Lift Grounds (of all conductors in the circuit) at both ends of the faulted cable section. When the transmitter SFL is ON, the external OUTPUT JACK produces a high voltage. Do not touch the jack! Electrical shock will result! 4 Attach Transmitter to Conductor Check Fault Resistance 1. Make sure transmitter is powered OFF. 2. Plug Black and Red conductive leads into the transmitter. 3. Stretch the Black-lead 180 away from conductor. 4. Push the ground rod into earth and clamp the Black lead to ground rod. Establish the best ground possible. See Figure 3-1 Figure 3-1: Clamping Black Lead to Ground Rod; Clamping Red Lead to Conductor 5. Clamp Red lead to target conductor sheath. See Figure Push transmitter SFL key. Check measured fault resistance on transmitter display. See Figure 3-2
10 10 Fault Severity Guide: KΩ Severe Fault KΩ Medium Fault 1 MΩ and above Light Faults Figure 3-2: Transmitter display in SFL mode 7. Select frequency - 9.8KHz or 82KHz, pressing the f button on the Transmitter keypad. 5 Use the i5000 Utility Line Locator Receiver to Trace the Cable Press the frequency softkey (Freq) on the receiver until the frequency selected on the transmitter is displayed. Trace and mark the cable as you proceed towards the fault. 6 Synchronize The A-Frame Receiver And Establish Reference Value Of Fault (A-Frame receiver has a one-color band above each spike (Black or White) 1. Hold the A-Frame Receiver so the spike with the Black band is about two (2) steps away from the ground rod and the spike with the white band is in-line with the targeted cable. The A-frame receiver must be placed as shown in Figure 3-3 for synchronization and for unit to operate correctly. Push the A-Frame spikes firmly into the ground. Turn the A-Frame ON. Wait until the arrow flashes. Figure 3-3: Positioning of A-Frame Receiver for Synchronization 2. Monitor bar-graph LCD display for arrow direction. If the arrow points AWAY from the ground rod, there is a fault.
11 11 3. If the arrow points TOWARDS the ground rod, there is no fault, and grounds and connections need to be rechecked. 4. The number of bars on the LCD indicates the potential gradient associated with the fault at the synchronization location. 5. The number of bars will decrease when you move away from the synchronization location and will increase when you get closer to the targeted fault. See Figure 3-4 Figure 3-4 : Locating the Cable Fault with A-Frame Receiver 7 Pinpoint the Fault 1. Keep the A-Frame parallel to the target cable. 2. Insert the A-Frame firmly in the ground every (3-6 m). Follow the arrow. 3. When the arrow changes direction, the fault may have been reached or passed. Look at the number of bars activated as well as the Actual LCD reading and compare them to number of bars you read at synchronization point as well as the Reference LCD reading. If the number of bars or the Actual and Reference readings are similar to the number of bars at synchronization point, you have located the main fault.
12 12 4. Backtrack. 5. Insert the A-Frame every 2 (.5 m) until the arrow changes direction again. 6. Move the A-Frame across the cable until a slight movement causes the arrow to change direction. The fault is located at the center of the A-Frame. 7. Check entire cable for multiple faults. If more faults are present, check the Active LCD number at each fault site and compare it to the Reference number. The higher the Active number the larger the fault.
13 13 4 SFL-2 A-FRAME RECEIVER TECHNICAL SPECIFICATIONS Metrotech offers two A-Frame models logarithmic or linear. Selecting which model will depend upon the intended application. 4.1 LOG A-FRAMES FOR POWER UTILITIES: Typically, operators looking for faults on power cables around 20 KΩ 25 KΩ. The Log A-Frame is designed to have greater resolution within this range and therefore, able to differentiate the strength of several faults. 4.2 LINEAR A-FRAMES FOR TELECOM UTILITIES: Telecom faults, however, are typically higher resistance faults than power. The Linear A-Frame provides greater sensitivity in the fault range of 100 KΩ 10 MΩ to detect multiple faults in a cable. 4.3 TECHNICAL DATA Frequency: Input Sensitivity: Sensitivity Control: 4.8 Hz Crystal Controlled 5 MV Automatic Active/Reference Signal Sensitivity Logarithmic: Battery: Battery Life: Battery Test: Weight: Dimensions: Operational Temp: Linear: V NEDA 1604 or equivalent 100 hr. continuous use Automatic at power ON for 3 sec. 4.4 lb (2.0 kg) 32 H x 22 W x 1 D (81 cm H x 56 cm W x 2.5 cm D) -4 F F (-20 C + 50 C) 4.4 A-FRAME RECEIVER CONTROLS AND INDICATORS See Figure 4-1 for the location of the Receiver controls described below:
14 14 On/Off Button: Figure 4-1: A-Frame Controls and Indicators Push and release to turn ON. Push and release to turn OFF. LCD Bar Graph Display: The bar graph indicates three types of information: 1 Battery Status: The solid bars indicate the battery level. If only one bar appears, replace the battery. The battery status is displayed for three (3) seconds at Power ON. 2 Direction of Fault: The flashing arrows will display the direction to the fault 3 Magnitude of Fault The bar graph consists of twelve (12) bars with each bar representing the magnitude of the fault(s) as described below. Impedance (Ω) Logarithmic Linear Bars Active/Reference Active/Reference K K K K K K K K M ADDITIONAL A-FRAME RECEIVER FEATURES
15 Battery Access Plate Located on the underside of Receiver control panel. Remove the two thumbscrews to release the plate. See Figure Conductive Pads The A-Frame Receiver is shipped with two protective foam pads with large washers attached to the Receiver probes. These pads are used for tracing on dry, hard surfaces. Protect and save these conductive pads and washers.
16 16 5 PRINCIPLES OF OPERATION 5.1 FUNCTIONAL THEORY Reviewing the basics of sheath fault locating is a valuable exercise before proceeding even for experienced users. This will improve the chances of finding the fault and saving time. Comparing electrical current to water flowing through a pipe applies extremely well to fault locating. Just like trying to find a leak in a water pipe, you might seal off one end, pump water into the other, and look for water to appear near the leak. The principles of sheath fault locating are identical. The cable equivalent of sealing off the pipe is to lift all connections at both ends of the cable, creating a high resistance open condition. The water in this case is the current flowing through the cable towards the fault. We look for the current leak with an A-Frame. Both ends of the cable must be disconnected from ground. The SFL-activated transmitter applies a low frequency signal between an isolated conductor with an earth fault and another ground point. This 4.8 Hz signal is induced into the ground from the fault location. The A-Frame Receiver contact probes detect this signal pattern. A typical hookup for locating a sheath fault, also called a shield-to-earth fault, is illustrated in Figure 5-1.
17 17 Figure 5-1: Typical SFL-2 Transmitter Connection 1. Black Lead 2. Red Lead 3. Ground Rod 4. Fault 5. Faulty conductor open on both ends
18 18 As current flows from the transmitter and through the fault, an earth voltage gradient field is created. Its center is at the fault. This gradient field has a pattern as depicted in Figure 5-2, like pond water ripples when you throw a rock in it or the rings of a tree stump.) Figure 5-2: Signal Pattern Around Fault and Ground Point The A-Frame Receiver compares the readings taken by the two probes and determines the direction and size of the fault. Directional blinking arrows guide the operator to the exact source of the fault. The A-Frame s bar graph and numerical active LCD display indicates the relative distance to the fault and it is size Earth Voltage Gradient Note in Figure 5-2 that the gradient pattern appears to be concentric circles near the fault. Properly interpreting this pattern is the key to successful operation of the i5000 SFL unit Equipotentials The circles shown in Figure 5-2 represent lines of equal voltage. The boxes show what the bar graph will display with the A-Frame in different positions. Thus, if the A-Frame were inserted so that both of the ground spikes were on the same circle, there would be no difference in voltage between them. The bar graph will show zero, the arrows will
19 19 become erratic and the numerical active display will show a zero. One of these positions occurs when the fault is directly between the spikes. This result can also occur midway between the ground spike and a fault and when the A- frame is exactly perpendicular to the fault. There is a return field around the transmitter ground spike. As you move toward the fault, the bars and the active numerical number will decrease until you reach the midpoint between the fault and ground spikes. At the half waypoint between the fault and ground spike, the signal strength is at it is absolute lowest. At this point the bar graph and active display will show zero and the arrows become erratic. To determine if you are midway between faults or directly over a fault, move the A- Frame further from the transmitter and measure again. If the arrows tell you to continue in this direction, the zero point was a midpoint. If the arrows tell you to return toward the transmitter, the zero point was a fault. As you continue, they will increase until you reach the fault. Nearly 70% of the signal exists within the last 1/3 of the distance between the ground spike and the fault. The amount of signal measured and displayed by the A-Frame is proportional to the number of field lines in Figure 5-2 between the A-Frame spikes. Thus, the maximum signal point occurs when one A-Frame spike is directly above the fault. By probing around the ground point, a user can learn what to expect at the fault from the A-Frame bar graph response. As shown in Figure 5-2, the signal pattern around the fault and ground point is identical (if there are no nearby conductors). This means that the A- Frame will react the same way around the fault as at the ground point. As you move toward the fault, the bars and the active numerical display will decrease until you reach the midpoint between the fault and ground spike. As you continue, they will increase until you reach the fault Multiple Fault Patterns The signal pattern created by two faults in a line is depicted in Figure 5-3. The two faults are shown without the ground point. Notice that from a distance the two faults will have the appearance of a single fault due to the equipotential circle around them both. As you get closer, the individual faults become apparent. There is an area between two faults where the A-Frame may give a false indication of another fault. This is caused by the two faults canceling each other. Errors can be avoided in this situation by following the procedure described in Section 7.7. We recommend that multiple faults be attacked one at a time. Whenever a fault is positively located, it should be repaired before looking for the other faults.
20 20 F1 F2 Figure 5-3: Multiple Fault Signal Patterns Distortion Due to Adjacent Conductors Whenever a non-insulated adjacent conductor lies between a fault and the ground return point, the return current tends to concentrate on the conductor instead of flowing through the earth. This situation can shrink the signal pattern near the fault, which would tend to reduce the detectable signal away from the fault. Possible distortion problems such as the described situation can be avoided by first tracing the faulty conductor and looking for adjacent conductors prior to fault locating.
21 21 6 Calibration Test Procedure Perform this instrument test procedure on a lawn prior to field site use. If grass or dirt is not available, indoor carpeting may be used. 1 Check the Batteries Turn the transmitter ON. The transmitter LCD will display the battery capacity level. Ensure the transmitter battery is fully charged for optimal operation. Turn the transmitter OFF. Turn the A-Frame Receiver ON. The solid bars indicate the battery level. If only one bar appears, replace the battery (1 each, 9V). The battery status is ON for 3 seconds at turn on. 2 Connect the Test Cables Connect the Black and red connection leads to the transmitter OUTPUT JACK. See Figure 6-1. Figure 6-1: Checkout Test Set-Up 3 Spread the Test Leads as Far Apart as Possible Insert the ground spike and attach the Black cable. Insert a screwdriver into the ground and connect the Red cable to it, creating a simulated fault. This test can also be done by pushing the metal end of the clamps directly into the ground so that they make electrical contact. When using a carpet in this checkout procedure connect test cable clamps directly to the carpet. 4 Push the SFL transmitter button on the keypad
22 22 Wait for the SFL high-voltage output to be generated and observe the fault resistance transmitter display. 5 Synchronize the Receiver Hold the A-Frame so the black spike is closer to the ground connection. Push the A-Frame firmly into the ground. 6 Push the Receiver On/Off Switch to ON The A-Frame Receiver will repeat its battery test. After the battery test, the arrow facing the simulated fault (Red test clamp) flashes and a potential gradient number is shown on the Active and Reference LCD display. 7 Rotate the A-frame 180 Note that the arrow now facing the red test clamp flashes. As the A-Frame is moved around the fault the arrow closest to the simulated fault should flash.
23 23 7 OPERATION 7.1 CHECK THE BATTERIES PRIOR TO GOING INTO THE FIELD. Follow the transmitter battery check procedures provided in the i5000 Utility Locating System operating manual. Turn the A-Frame Receiver ON. The solid bars indicate the battery level. If only one bar appears, replace the battery (1 each, 9 volt). The battery status is displayed for 3 seconds at turn on. 7.2 ENSURE ALL CONDUCTORS IN THE FIELD ARE DE-ENERGIZED 7.3 LIFT THE GROUNDS Lift the grounds (of all conductors in the circuit) at both ends of the faulted cable section. Occasionally, the very experienced fault locators see evidence (i.e. tripped circuit breakers at transformer) that the fault is so severe that no signal will travel beyond the fault. In these cases, it is not necessary to lift the distant ground. 7.4 ATTACH THE TRANSMITTER TO THE CONDUCTOR AND CHECK THE FAULT RESISTANCE. 1 Turn the transmitter OFF. 2 Plug the Black and Red test leads into the transmitter. 3 Clamp Red lead to target conductor sheath. Make sure the red clamp does not make contact with any leaves, grass, or dirt. This could create false reading. WARNING When the transmitter is set to SFL the external OUTPUT JACK produce up to 1200 volts. Do not touch these jacks, electrical shock will result! Do not place a shorting bar across external Output Jacks, or connect the two leads together. Damage to the transmitter may result. CAUTION 4 Stretch Black lead 180 degrees away from the Conductor. 5 Push grounding rod into the earth and clamp the Black lead to the grounding rod. Establish the best ground possible. 6 Turn the i5000 transmitter ON and push the SFL key to switch the transmitter into SFL operating mode. Check transmitter battery status. 7 Check the fault resistance on transmitter display. Severe faults read in the KΩ, medium faults will read in the 100 KΩ 500 KΩ, and light faults will read 1 MΩ and up. To switch between 82KHz and 9.82KHz frequencies for line tracing, push the f (frequency) button on the transmitter keypad. In SFL mode, the
24 24 transmitter will simultaneously generate a 4.8Hz low frequency fault locating tone as well as 9.8 Hz or 82kHz cable tracing frequency. 7.5 SYNCHRONIZE THE A-FRAME RECEIVER By synchronizing, the A-Frame memorizes the phase of the transmitter signal. This allows it to recognize the reverse phase signal coming from the fault and direct you to it. Resynchronize the Receiver every 45 minutes to maintain optimum calibration. You may do this near the ground rod or near a fault. At the ground rod, the black A-Frame spike must be nearer to the ground rod with the white spike facing toward the fault. At a fault, the white A-Frame spike must be nearer to the fault. 1 Hold the A-Frame so the black spike is closest to the ground rod. 2 Push the A-Frame spikes into the ground. 3 Switch the Receiver ON. Wait until the arrow flashes on the bar graph. 4 If the arrow points away from the ground spike, there is a fault. 5 If the arrow points towards the ground spike, there is no fault. Recheck the grounds and connections if a fault is wrongly given. See Figure 7-1. Figure 7-1: Synchronizing The A-frame 7.6 CONFIRM THAT A FAULT EXISTS 1 Remove the A-Frame from the ground.
25 25 2 Rotate it 180 and re-insert it into the ground. The arrows should reverse directions and point away from the ground spike. 7.7 TRACE THE CABLE WITH THE I5000 RECEIVER The i5000 Utility Line Locator allows you to trace the line and search for the fault at the same time. 1 Check the i5000 Receiver for cable tracing frequency. Aim the Receiver at the Red lead and cycle through the Receiver frequencies 9.8KHz or 82KHz, to confirm that the selected tracing frequency is being received. 2 Trace and mark the cable as you proceed towards the fault. 7.8 PINPOINT THE FAULT 1 Keep the A-Frame parallel to the target cable 2 Insert the A-Frame every (3-6 m). Follow the arrow and monitor the active number. 3 When locating with the A-Frame, make sure that the probes are inserted well into the ground. A good physical ground connection is needed to receive strong signal. 4 When the arrow changes direction, back track. Check the Active LCD number and compare it to the Reference LCD number. If both active and reference numbers have the same or similar value, you have found the major fault. 5 Insert the A-Frame every 2 (50 cm) until the arrow changes direction again, then turn it 90 degrees. Check for obvious causes where a fault is suspected, such as recent excavation. 6 Continue to move the A-Frame across the cable until a slight movement causes the arrow to change directions. When this happens, the fault is located at the center of the A-Frame. 7.9 VERIFY THE FAULT 1 Move slightly off to one side of the cable. 2 Insert the A-Frame into the ground at various positions around the suspected fault site (like the hands of a clock). 3 The arrow should always point toward the fault. 4 Place the other spike in the ground at the fault site and repeat the process. The arrow should always point inward, toward the fault. See Figure 7-2. Place the other spike in the ground at the fault site and repeat the process. The arrow should always point inward, toward the fault.
26 26 Figure 7-2: Fault Confirmation
27 27 8 ADVANCED TECHNIQUES 8.1 FAULTS UNDER INACCESSIBLE SURFACES When the faults exist beneath a paved or other inaccessible area, the fault may be located using one of the following methods Perpendicular Method Carefully trace the location of the faulty conductor. Hold the A-Frame parallel to the cable path. As you move away from the ground rod the bar graph and the active number will gradually decrease until reaching the midpoint. It will then increase until reaching the fault. When the A-Frame center passes a line perpendicular to the sheath fault, the directional arrow indicators will rapidly change positions and the bar graph and active number will drop to zero. See Figure 8-1. Cable Fault Paved Surface Figure 8-1: Perpendicular Method Triangulation Method As shown in Figure 8-2, (the point where the signal strength is a minimum) if the A- Frame is positioned exactly on an equipotential circle, a perpendicular line from the center of the A-Frame will pass through the fault. The intersection of any two such perpendicular lines defines the fault location. Cable Fault Paved Surface Figure 8-2: Triangulation Method
28 28 To find an equipotential circle (see Figure 8-3) insert the A-Frame into the ground and pivot around one spike. Rotate the A-Frame back and forth until the exact point is found where the flashing arrows change direction. The A-Frame is now on an equipotential circle and is perpendicular to the fault. By marking this line and repeating the process with the A-Frame at another nearby location, the two lines will intersect or cross at the fault. Figure 8-3: Locating an Equipotential Circle 8.2 FAULTS UNDER PAVEMENT Faults under pavement or other slightly conductive surfaces can be found using the foam pads supplied with the unit. Saturate the pads with water and insert the A-Frame spikes into the pads. Locate the fault as you normally would. Be sure to keep the pads as moist as possible, but do not let the water form a continuous puddle between the pads as this will short out the signal. 8.3 LONG DISTANCE TRACING As the distance to the fault increases, the signal picked up by the A-Frame is proportionally reduced. This condition can lead to problems if the signal levels are reduced to the point that they can no longer be detected by the A-Frame. Whenever working with weak signals due to long distance faults (or other reasons), increased sensitivity can be obtained by extending the distance between the A-Frame spikes using the extension cable. This extension method can be applied to any of the previously discussed methods including the conductive foam pads. When working with very long distances, as in fiber optic runs, the sensitivity can be increased even further using a longer insulated wire to extend the A-Frame span. See Figure 8-4.
29 29 Figure 8-4: Fault Location Using Extension Cable for Increased Sensitivity 8.4 HIGH AND LOW IMPEDANCE FAULTS Before beginning a fault search it is a good idea to know the severity of the fault. This is measured in terms of its resistance or impedance to ground. Faults where the ground is wet and/or a very large piece of the insulation is missing are found at the low end of the range (<500 Ohms). Conditions where the ground is very dry and/or the actual fault is a small pinhole where the conductor has a very small ground contact area are found at the high end of the fault range (>1-3 MΩ). A low impedance fault is the easiest to find since there is more signal to detect. Generally, the more bars and a higher number displayed at synchronization, the larger the fault. A high impedance fault is more difficult to locate. Characteristically, the A-Frame Receiver may not detect the signal after moving a short distance away from the ground point. The higher the impedance of the fault, the closer you must be to detect it. For Example. If the A-Frame only reliably points away from the ground connection within 20 (3 m), then the A-frame will only detect the fault within about 20 (3 m). Outside this distance the signal is too weak to reliably detect. For this reason we highly recommend tracing and marking the line before searching out high impedance faults. 8.5 MULTIPLE FAULTS Locating multiple faults is the most difficult and confusing fault situation. It is especially important in this case to accurately trace the faulty conductor before beginning the fault
30 30 search. Stay exactly above the line if possible and verify each suspected fault by monitoring the active number to see which fault has the higher number. Remember that a very strong or low impedance fault will mask the detection of a weak or high impedance fault. The safest and best way to find multiple faults is to repair each fault as it is positively identified and then continue the search. See Figure 5-3.
31 31 9 MAINTENANCE 9.1 RECEIVER BATTERY REPLACEMENT. Loosen the two thumbscrews located on the underside of the Receiver housing. Gently pull out battery door. Be careful not to pull on the battery wires. Remove battery from battery holder and disconnect battery. Reverse procedure for installing new battery. Connector Figure 9-1: Receiver Battery Replacement
32 SERVICE CENTERS If the instrument does not function properly, replace the battery as described above. If the equipment still malfunctions, contact one of our Metrotech Customer Service departments for assistance: Vivax-Metrotech Corporation 3251 Olcott Street, Santa Clara, CA 95054, USA Website : Sales & Sales Support: T/Free : Tel : Fax : [email protected] Application Support: T/Free : Tel : Fax : [email protected] Service & Repairs: T/Free : Tel : Fax : [email protected] All Other Department: T/Free : Tel : Fax : Canada Vivax Canada Inc. 400 Esna Park Drive, Unit 17, Markham, Ontario, L3R 3K2, Canada Tel : Website : [email protected] Europe SebaKMT Seba Dynatronic Mess-und Ortungstechnik GmbH Dr.-Herbert-Iann-Str. 6, Baunach, Germany. Tel : Fax : Website : [email protected] Australasia SebaKMT AUS Unit 1, 176 South Creek Road, Cromer NSW 2009, Australia Tel : Fax : Website : [email protected] [email protected] China Leidi Utility Supply (Shanghai) Ltd. Rm405 3rd Building No. 641, Tianshan Rd, Shanghai, China Tel : Fax : Website : [email protected] Or call the factory for the nearest authorized Metrotech repair station. Additional Metrotech Instruments: Pipe and Cable Locators, Dual Frequency Locators, Magnetic Locators, Fiber Optic Cable Locating System, Leak Detectors, Valve Box Locators, and High Power Locators.
33 33 10 APPENDIX A1 APWA Marking Colors - The following color markings have been established by the American Public Works Association (APWA): Conductor Color Electric power lines, cables, or conduits Red Communication lines, cables, conduits, CATV Orange Gas, oil, petroleum, or other gaseous materials Yellow Sewers, storm and sanitary, drain lines Green Water, irrigation, or slurry lines Blue If you have any questions regarding marking requirements or procedures in the United States, please call your local One Call Center. International customers: please check with your local regulatory authorities or utility companies required color markings may vary between different countries.
34 34 11 COPYRIGHT NOTICE The information contained in this document is for informational purposes only and is subject to change without notice. Metrotech Corporation makes no warranty of any kind with regard to the information contained in this manual, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Metrotech shall not be liable for errors contained herein, nor for incidental or consequential damages from the furnishing of this information. This manual contains proprietary information that is protected by copyright. All rights are reserved. No part of this manual may be photo-copied, reproduced, magnetically stored, transmitted, or translated into another language without the prior written consent of Metrotech Corporation. Bluetooth is a registered trademark of Bluetooth SIG. Metrotech Corporation
35 35 12 WARRANTY THERE ARE NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY, BEYOND THOSE STATED HEREIN. Metrotech warrants it is equipment to be free from defects in workmanship and material under normal and proper use and service for one year from date of purchase by original user. Metrotech assumes no obligation to repair or replace equipment which has been altered or repaired by other than a Metrotech-approved procedure, been subject to misuse, misapplication, improper maintenance, negligence, or accident; has had it is serial number or any part here of altered, defaced ore removed; or been used with parts other than those approved by Metrotech. Warranty does not include batteries. Expendable items such as fuses and lamps are excluded. Any detection product proved defective under this warranty will be repaired or replaced free or charge at the Metrotech Corporation factory or approved Metrotech repair station. The equipment should be returned to our factory by prepaid transportation after requesting and receiving return authorization from our Service Department. Metrotech s obligations are limited to repair or replacement of broken or defective parts, which have not been abused, misused, altered, or accidentally damaged, or at the option of Metrotech, to refund of the purchase price. Metrotech assumes no liability for removal or installation costs, consequential damages, or contingent expenses of any other nature. Part #:
i5000 Utility Locating System 10W Transmitter SERVICE CENTER, SALES AND TECHNICAL SUPPORT INFORMATION
i5000 Utility Locating System OPERATIONS MANUAL 10W Transmitter SERVICE CENTER, SALES AND TECHNICAL SUPPORT INFORMATION Vivax-Metrotech Corporation 3251 Olcott Street, Santa Clara, CA 95054, USA Website
Dynatel 2273 Advanced Cable and Fault Locator
Dynatel 2273 Advanced Cable and Fault Locator Operators Manual September 1999 78-8097-6517-1-B TABLE OF CONTENTS Introduction... 2 Installing or Replacing the Batteries... 2 Initial Receiver Configuration...
Water Leak Detection System. Metrotech HL 6000 PC Correlator Operations Manual
Water Leak Detection System Metrotech HL 6000 PC Correlator Operations Manual THE INFORMATION CONTAINED IN THIS DOCUMENT IS FOR INFORMATIONAL PURPOSES ONLY AND IS SUBJECT TO CHANGE WITHOUT NOTICE. METROTECH
Seven function digital multimeter
Seven function digital multimeter 98025 Set up And Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com
Manual Ranging MultiMeter
Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!
Owner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
Model 450 Mag Horn Ferromagnetic Locator
Model 450 Mag Horn Ferromagnetic Locator User s Manual Manufactured Exclusively By: Utility Tool Company, Inc. 2900 Commerce Boulevard Birmingham, Alabama 35210 205-956-3710 User s Hotline 800-952-3710
AutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
Mini-led spotlight with magnetic base
Mini-led spotlight with magnetic base Model 95799 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission
Compaq Presario Desktop Products. Upgrading and Servicing Guide
Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to
7 FUNCTION DIGITAL MULTIMETER
7 FUNCTION DIGITAL MULTIMETER 90899 OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2004 by Harbor Freight Tools. All rights
How To Use A Cdm250 Digital Multimeter
User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this
3M Wrist Strap and Footwear Tester 740. User s Guide
3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6
±15 V Current-Limited Power Supply
USER S GUIDE ±15 V Current-Limited Power Supply Model 0901 Newport Corporation 3635 Peterson Way Santa Clara, CA 95054 www.newport.com/newfocus Warranty Newport Corporation guarantees its products to be
ExStik TM ph Waterproof Meters
User Guide ExStik TM ph Waterproof Meters Models PH100 & PH110 Patent Pending ExStik TM Description Front Panel Controls 1. Battery compartment cap 2. LCD Display 3. MODE / HOLD button 4. CAL / RECALL
Cable And Pipe Signal Receiver
OPERATION AND SAFETY INSTRUCTION MANUAL Cable And Pipe Signal Receiver Part 17-300R Cable And Pipe Signal Receiver Part 17-300RTK Cable And Pipe Signal Receiver With Transmitter Part 17-500T Transmitter
CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual
CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CGWTS-M001A Version 1, Release 1, December 2004 NOTICE
EPM3. Phase Sequence and Motor Rotation Tester. Users Manual
EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
Essential Electrical Concepts
Essential Electrical Concepts Introduction Modern vehicles incorporate many electrical and electronic components and systems: Audio Lights Navigation Engine control Transmission control Braking and traction
Installation and Operation Guide for PD5100 Automatic Transfer Switch
Installation and Operation Guide for PD5100 Automatic Transfer Switch Member P r o gr e ssive Dynamics, Inc. 507 Industrial Rd Marshall, MI 49068 www.progressivedyn.com 2012 Progressive Dynamics, Inc.
i410/i1010 AC/DC Current Clamp
/i1010 AC/DC Current Clamp Instruction Sheet Safety Information XW Read First: Safety Information To ensure safe operation and service of the current clamp, follow these instructions: Read all operating
RT-200 HI-TEST ROPE TESTER
RT-200 HI-TEST ROPE TESTER Operating & Instruction Manual HD ELECTRIC COMPANY 1 4 7 5 L A K E S I D E D R I V E W A U K E G A N, I L L I N O I S 6 0 0 8 5 U. S. A. P H O N E 8 4 7. 4 7 3. 4 9 8 0 FA X
Model SRMD Setra Remote Monitoring Display
Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for
Installation and Operation Guide for PD4000 Series Power Control Center
Extended warranties are available for purchase at www.progressivedyn.com Installation and Operation Guide for PD4000 Series Power Control Center Member Thank you for selecting Progressive Dynamics as your
User s manual FLIR VP50/VP52 Non-contact AC voltage detector
User s manual FLIR VP50/VP52 Non-contact AC voltage detector User s manual FLIR VP50/VP52 #T559851; r. AD/ 9134/9134; en-us Table of contents 1 Disclaimers... 1 1.1 Copyright... 1 1.2 Quality assurance...
Electrical Safety Tester Verification
Ensuring Validity of Regulatory Tests Verification of electrical safety testing equipment is a procedure that is often overlooked by manufacturers. Running test verification is crucial to ensuring that
SYSTEM MIX PLUS. Owner's Manual DIGITAL MUSIC CORPORATION
SYSTEM MIX PLUS Owner's Manual 1 Table of Contents 1. Introduction.................. 2 1.1 Overview 1.2 Unpacking 2. Operation................... 3 2.1 Front Panel 2.2 Rear Panel 3. Mixer.....................
Instruction Manual Temp 4/5/6 Temperature Meter Series
Instruction Manual Temp 4/5/6 Temperature Meter Series 68X243607 Technology Made Easy... Rev. 2 01/03-1 - Preface This instruction manual serves to explain the use of the Temp 4/5/6 temperature meter.
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
Sunny Boy Accessories SMA POWER BALANCER
Sunny Boy Accessories SMA POWER BALANCER Installation Guide SBUS-PowBal-IUS102810 IMUS-SBUS-PBL Version 1.0 US SMA America, LLC Legal Restrictions Copyright 2010 SMA America, LLC. All rights reserved.
FUJI DIGITAL SOUND DETECTOR FSB-8D INSTRUCTION MANUAL
FUJI DIGITAL SOUND DETECTOR FSB-8D INSTRUCTION MANUAL Instruments for the location of underground utilities and water leaks. INDEX Page USE... 3 WARRANTY... 3 FOR SAFE USE... 4 BEFORE USE THE DETECTOR...
HP ProDisplay P19A LED Backlit Monitor. User Guide
HP ProDisplay P19A LED Backlit Monitor User Guide 2013 Hewlett-Packard Development Company, L.P. The only warranties for HP products and services are set forth in the express warranty statements accompanying
3088 Lockout-Tagout Training Program Course Outline
3088 Lockout-Tagout Training Program Course Outline The following outline summarizes the major points of information presented in the course. The outline can be used to review the course before conducting
About this Manual. Support for Your Product
About this Manual We ve added this manual to the Agilent website in an effort to help you support your product. This manual is the best copy we could find; it may be incomplete or contain dated information.
3 WATT LED SPOTLIGHT Model No. SLM - 3801
3 WATT LED SPOTLIGHT Model No. SLM - 3801 OWNER'S MANUAL Customer Service Tel: 1-800-268-3319 Superex Canada Ltd, Toronto,M2H 3B8 Made in China Table of Contents A). Important Safety Instructions B). Charging
Mini Power Bank and Charger
Mini Power Bank and Charger Owner s Manual Please read before using this equipment. Your charger is ETL listed to UL standards and meets all applicable FCC standards. WARNING: To reduce the risk of fire
Operation and Installation Manual
Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control
CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13
CONTROL PANEL INSTALLATION INSTRUCTIONS Single Phase Simplex Page 2-7 3-Phase Simplex Page 8-13 Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions
ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1
ITC-BTTN Cellular Bluetooth Gateway Owner s Manual 1 2 Table of Contents Introduction...3 Package Contents...3 XLink Connections Diagram...4 Setup...5 Pairing your Bluetooth Cell Phone to the XLink...6
RD2000: SuperC.A.T + SuperC.A.T TL SuperC.A.T S SuperC.A.T CPS T1 Transmitter User Guide
RD000 SuperC.A.T RD000: SuperC.A.T + SuperC.A.T TL SuperC.A.T S SuperC.A.T CPS T Transmitter User Guide RD000 SuperC.A.T User Guide Functions SuperC.A.T Locator functions 4 6 On/Off Trigger. Press and
Owner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
Microwave Meter. Instruction Manual
Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted
OAK WORKBENCH WITH 2 DRAWERS
OAK WORKBENCH WITH 2 DRAWERS Model 93991 ASSEMBLY Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious injury.
LCD5500Z / PKP-LCD v3.x Installation Instructions
LCD5500Z / PKP-LCD v3.x Installation Instructions TM Introduction The LCD5500Z / PKP-LCD keypad displays system status using an LCD screen. The keypad can be used on PowerSeries security systems with up
Installation and Operation Guide for PD4100 Series Power Control Centers
Installation and Operation Guide for PD4100 Series Power Control Centers Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as
Owner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
OPERATING INSTRUCTIONS
PIPELINE INSPECTION COMPANY LTD. OPERATING INSTRUCTIONS Wet Sponge Holiday Detectors 670,673, and MSRB Wet Sponge Holiday Detectors Portable and In-Plant Detectors Table of Contents General Information.......................3
TRIPLETT TDR. Cable Fault Finder. Instruction Manual
TRIPLETT TDR Cable Fault Finder Instruction Manual Safety Warnings This Instrument meets the safety requirements of IEC 61010-1:1993. It is for use on de-energised circuits only, however the Instrument
Ground Resistance Clamp-On Tester
User s Manual Ground Resistance Clamp-On Tester MODEL 382357 Warranty EXTECH INSTRUMENTS CORPORATION (a FLIR company) warrants the basic instrument to be free of defects in parts and workmanship for one
User Manual. CFG253 3 MHz Function Generator 070-8362-04
User Manual CFG253 3 MHz Function Generator 070-8362-04 Copyright Tektronix, Inc. 1993. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information
CHECKING AND TESTING ELECTRICAL INSTALLING WORK
CHECKING AND TESTING ELECTRICAL INSTALLING WORK Department of Consumer and Employment Protection Energy Safety Preface It is a requirement of the Electricity (Licensing) Regulations 1991 that all electrical
Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1
REMOTE METER TM Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1 1098 Washington Crossing Road Washington Crossing, PA 18977 USA www.morningstarcorp.com
Ground Resistance Clamp On Tester
USER MANUAL Ground Resistance Clamp On Tester MODEL 382357 Introduction Congratulations on your purchase of Extech s 382357 Ground Resistance Tester. This Clamp on device allows the user to measure ground
DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No. 20-225. Please read before using this equipment.
20-225.fm Page 1 Wednesday, August 4, 1999 10:07 AM Cat. No. 20-225 OWNER S MANUAL Please read before using this equipment. DX-395 FM/AM/SW1/SW2 PLL Synthesized Receiver 20-225.fm Page 2 Wednesday, August
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12
Table of Contents The Basics of Electricity 2 Using a Digital Multimeter 4 IDEAL Digital Multimeters An Introduction The Basics of Digital Multimeters is designed to give you a fundamental knowledge of
Wireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
Model UT201/202: OPERATING MANUAL. Table of Contents
Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons The Effectiveness
LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL 16350 TYPE 12/24EL40-10ET
LESTRONIC DV AUTOMATIC 12 OR 2 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL 16350 TYPE 12/2EL0-10ET PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS For correct operation of the equipment,
Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe
Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe MODELS: ES712, ES914, ES149, ES1814, ES813, ES916, ES1014, ES2014, ES412, WES149, WES2114 Read Contents Carefully
el-720 Carbon Dioxide Gas Leak Detector User s Guide
el-720 Carbon Dioxide Gas Leak Detector User s Guide Congratulations on the purchase of the AccuTools el-720 Carbon Dioxide Gas Leak Detector, the most technologically advanced instrument of its kind.
Achat 115MA full-range speaker. user manual
Achat 115MA full-range speaker user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: [email protected] Internet: www.thomann.de
AVerMedia AVerKey imicro User s Manual
FCC NOTICE This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
User Guide. HDMI Active Cable Extender. DVI-7370c
User Guide HDMI Active Cable Extender DVI-7370c TABLE OF CONTENTS SECTION PAGE PRODUCT SAFETY...1 PRODUCT LIABILITY...1 1.0 INTRODUCTION...2 2.0 SPECIFICATIONS...3 3.0 PACKAGE CONTENTS...4 4.0 CONNECTING
PALLET JACK - 2.5 TON
PALLET JACK - 2.5 TON 39939 SET UP AND OPERATING INSTRUCTIONS Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious injury.
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
READ FIRST! Universal Car/Air Adapter User Manual
AutoAir Manual 1/9/03 2:03 PM Page 1 READ FIRST! Universal Car/Air Adapter User Manual Congratulations! Your new Kensington Universal Car/Air Adapter is a highly efficient Universal Car/Air Adapter for
LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS
OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS LiteAide HE-100B HE-100BW HE-112 HE-112W HE-117 HE-117W HE-117-2B OWNER'S MANUAL FLOOD LAMPS (BULBS) Your
DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D
ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &
Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930
Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930 WARNING Ultraviolet light is harmful to eyes and skin. Never look at light produced by this lamp. Unplug lamp before servicing. Electrical
PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors. OPERATING INSTRUCTIONS SPY PORTABLE HOLIDAY DETECTORS Models 780, 785, & 790
PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors OPERATING INSTRUCTIONS SPY PORTABLE HOLIDAY DETECTORS Models 780, 785, & 790 Safety Disclaimer Only trained and responsible personnel should
Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012
Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012 Contents 1 Preliminary note 3 1.1 Symbols used 3 1.2 Warning signs used 3 2 Safety instructions
Digital Fingerprint safe
Digital Fingerprint safe Model 96846 Operation Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product
12-Volt 10-Amp Regulated Power Supply
22-506.fm Page 1 Friday, August 6, 1999 12:55 PM Cat. No. 22-506 OWNER S MANUAL Please read before using this equipment. 12-Volt 10-Amp Regulated Power Supply 22-506.fm Page 2 Friday, August 6, 1999 12:55
User Guide. RX-406 LED Keypad For CAPTAIN-I Ver.5.5 & up
RX-406 LED Keypad For CAPTAIN-I Ver.5.5 & up User Guide PIMA Electronic Systems Ltd. 5 Hatzoref Street, Holon 58856, Israel +972-3-6506444 +972-3-5500442 [email protected] http://www.pima-alarms.com
Benchtop Computer Monitor Generator
Model: 1280B Benchtop Computer Monitor Generator USER MANUAL Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases of
Leica DIGISYSTEM TM Safe and fast location of underground services
Leica DIGISYSTEM TM Safe and fast location of underground services Find it or avoid it the Leica DIGISYSTEM is your Key Why locate Brownfield sites have many and varied installed services and utilities
User and Installation Guide
Connect the AC adapter with the amplifier BEFORE plugging the AC adapter into an outlet to avoid spark generation! User and Installation Guide BlueFIDELITYTM Bluetooth Audio Amplifier Model 300 Contents
user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4
user s manual model #: SPB3200 Charger for Samsung Galaxy S 4 What s Included Unpack the battery case and make sure all accessories are put aside so they will not be lost. hello. USB to Micro USB Cable
WSD130 SOLDERING STATION
NOTES S2032ACH 8/98 Rev. 11/01 WSD130 SOLDERING STATION 1. Power Switch 2. Digital Display 3. UP Button 4. DOWN Button 5. Optical Regulator, Right 6. Connection for Soldering Iron, Right 7. Selection Switch
INSTRUCTION MANUAL MODEL PCD-88
INSTRUCTION MANUAL MODEL PCD-88 CLOSED CAPTION DECODER LINK ELECTRONICS, INC. 2137 Rust Avenue Cape Girardeau, Missouri 63703 Phone: 573-334-4433 Fax: 573-334-9255 e-mail: sales @ linkelectronics.com website:
Test Before Touch Easier Said Than Done. Ken Crawford, DuPont Kent Haggerty, Dupont
Test Before Touch Easier Said Than Done Ken Crawford, DuPont Kent Haggerty, Dupont Overview Test Before Touch (TBT) Principles Key Learnings by One Company One Method for Performing a TBT Induced Voltages
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
LUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
Pet hair clipper. Model 96822. Diagrams within this manual may not be drawn proportionally.
Pet hair clipper Model 96822 Cleaning And Operation Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the
staple gun with 5/16 Long staples
staple gun with 5/16 Long staples Model 95718 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
Instructions For SF 6 Refill Kit
S&C Vista Underground Distribution Switchgear UnderCover, Vault-Mounted, and Pad-Mounted Styles Instructions For SF 6 Refill Kit TABLE OF CONTENTS Section Page Section Page INTRODUCTION..................................
2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN-00076-A
2-3 SAS/SATA II HDD Canister XC-23D1-SA10-0-R USER S MANUAL Document number: MAN-00076-A ii Preface Important Information Warranty Our product is warranted against defects in materials and workmanship
Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL
Propane Conversion Kit Supersedes: 145.25-IOM2 (708) Form 145.25-IOM2 (908) PROPANE CONVERSION KIT INSTALLATION MANUAL "LPKIT " - PROPANE CONVERSION KIT Kits are available for field conversion from natural
TABLE OF CONTENTS 11.0 WARRANTY
11.0 WARRANTY OI-1009.205L TABLE OF CONTENTS ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original purchaser that this product is of merchantable quality and confirms in kind and quality
110244-003. PrintPAD CN3/4/3e/4e. User Guide
110244-003 PrintPAD CN3/4/3e/4e User Guide TABLE OF CONTENTS PrintPAD CN3/4 & PrintPAD CN3e/4e Printer Views...1 Open View...1 Closed View...1 Using Batteries: General Guidelines...1 Installing and/or
User's Guide. True RMS Industrial Multimeter
User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER
OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER P110 Your battery charger has been engineered and manufactured to Ryobi s high standard for dependability, ease of operation, and operator safety. When properly