HIGH VISCOSITY TEST OF A CRUDE OIL PUMP
|
|
|
- Ophelia Wheeler
- 9 years ago
- Views:
Transcription
1 HIGH VISCOSITY TEST OF A CRUDE OIL PUMP Brigitte Le Fur CETIM - Centre Technique des Industries Mécaniques 74, route de la Jonelière BP 82617, Nantes, France Cato Knutsen Moe EUREKA PUMPS Magnus Poulssons vei 7 NO-1366 Lysaker, Norway Fabien Cerru CETIM - Centre Technique des Industries Mécaniques 74, route de la Jonelière BP 82617, Nantes, France Dr. Brigitte Le Fur is now retired from Cetim, where she worked as a lead engineer in the Fluid and Flow Technologies Department. She attended ENSEEIHT in France where she received her engineering degree and PhD in fluid mechanics. She worked at Cetim to design test facilities for complex equipment using multi-phase flow and viscous fluids. She is the author of numerous papers on pumps and viscous flows. Cato Knutsen Moe is a Senior Specialist Engineer at Eureka Pumps Engineering Department. He joined Eureka Pumps in 9 and moved from the Application & Product Development Department to his current role in 13. He received his MSc degree at NTNU, Norwegian University of Science and Technology. Previously Mr. Moe worked for Kværner Eureka and AkerSolutions Subsea on several EPC- R&D projects within the Topside and Subsea Oil & Gas industry. He held various positions there and specialized in pump hydraulic design and development. Dr. Fabien Cerru is project and research engineer at CETIM in the Fluid and Flow Technologies Department. His organization is responsible for simulating and testing process equipment, e.g. valves, pumps, in a wide variety of conditions. Dr. Cerru attended ENSEEIHT in France where he received an engineering degree in fluid mechanics. He obtained his MSc at University of Manchester, U.K., in Thermal Power and Fluid Engineering and his PhD in Mechanical Engineering at Imperial College London, U.K. Previously, Dr. Cerru worked as a process and safety engineer at AREVA in the design of nuclear power plants. ABSTRACT In 14 a full scale high viscosity pump performance test was performed for a 2-stage vertically suspended (VS1) API61 pump. The high viscosity test scope was part of an ongoing EPC project and exclusively conducted for industrial purposes. The objective was to simulate real field operation with crude oil and qualify the pump for the given field conditions and requirements. Furthermore, the reason for conducting this test scope was the uncertainties in published methods of predicting high viscosity fluid pump characteristics, limited available literature, hence reduce field operation risks. The official test scope was divided into two main scenarios: 1) Start-up test at minimum. flow and a viscosity of 75 cp, 2) Pump performance test with an intermittent duty point (reduced flow) of 8 m3/h-125 m (3654 USgpm- 41 ft), and a viscosity of 175 cp. Internal tests with various viscosities from 48 cp to 75 cp were also done in preparation for the official tests. results were then compared to published methods for pump characteristics viscosity correction. The objective for these additional analyzes was to evaluate possible alternative approaches in order to improve uncertainties with viscous prediction and ultimately reduce the number of tests/test scope in future projects. It should be emphasized that this comparison is simply for discussion within the industry and not for validation of published methods of viscosity correction for pump characteristics.
2 The test results provide valuable insight on the effects of high viscosity on centrifugal pump performance curves, allowing a more accurate rating and possibly a better optimization of the process equipment, e.g. electrical motor, valves, cooling system, by improving the flow characteristics predictions. INTRODUCTION Crude oil viscosity variation with fluid temperature is affecting pump requirements: The driver must be able to start at the highest viscosity, as well as operate within the given requirements and over the applicable viscosity range. Due to uncertainties related to estimating the effect of the viscosity on the pump performance, extensive laboratory testing performed by Cetim was part of the EPC project scope in order to verify the pump performance. Official test scope was divided into two main scenarios to qualify the pump for the given field conditions and requirements: Start-up test at minimum flow and a viscosity of 57 cp, Pump performance test with an intermittent duty point (reduced flow) of 8 m 3 /h-125 m (3654 USgpm- 41 ft), and a viscosity of 175 cp. Internal tests with various viscosities from 1 cp up to 57 cp were also performed in preparation for the official tests. For certain pumps and specific speeds, the Hydraulic Institute provides viscosity correction factors based on pump performance curves for water, e.g. ANSI/ (1). These guidelines apply to the tested crude oil pump. The first Section presents the main criteria for the pump design. Then the test loop design is explained. The third part presents the test results and their comparison with the Hydraulic Institute predictions. However, the third part is limited and only for discussion within the industry and not for validation of the viscosity prediction methods. PUMP AND MOTOR With a satisfying pump characteristic and specific speed, a well proven design and several years in operation for both crude and Seawater Service, the pump evaluated and chosen for crude oil service was well suited. With this in mind, no extra- or special design measures were taken with respect to the pump hydraulics. However, special attention was made for the following points: Pump Characteristics established and satisfactory. This was achieved through previous performance tests from EPC projects. The uncertainties related to prediction of Pump Characteristics for viscous flow. Several published methods were investigated, both empirical and loss analysis approach. Due to the uncertainties related to prediction of Pump characteristics for viscous flow, a conservative approach for power- and torque rating on the electrical motor-, but also head was imperative. Sufficient head would be secured through increased impeller outlet diameter. With a maximum potential impeller outlet diameter of 5 mm (.9 inch) and the actual outlet diameter of 446 mm (17.6 inch) this was considered satisfactory. The main parameters for the given pump are presented in the following bullet points: Standard 2 stage Centrifugal pump, API 61 vertically Suspended (VS1). Total length in operation / Viscosity test: 51.5 m/ 8.6 m (168.9 ft/ 28.2 ft). The pump length was reduced for practical reasons by removing riser sections. Total weight (dry) operation/viscosity test: 11 kg/ 7 kg ( / lb) Specific speed (water) nq: 47 (rpm, m3/s, m), i.e. Ns=2428 US customary units Mechanical seal System: Plan 53B Squirrel-cage induction motor rating: 78 kw at 6 Hz (146 BHP) Speed: 1783 rpm at 6Hz, 149 rpm at Hz Rated/Normal Operating Point: 18 m3/h-125 m ( USgpm ft), viscosity: 181 cp, Re = 4.3x1 4 Intermittent Duty point Reduced flow: 8 m3/h- 125 m ( USgpm ft), viscosity: 175 cp, Re = 7.3x1 3 Intermittent start-up at minimum flow: viscosity: 57 cp, Re = 3.8x1 3 Also, see the pump sectional arrangement drawing in reduced length for test setup, Figure 1. Rated/Normal Operating Point (181 cp): The rated flow and head together with rotational speed determined the selection of a pump with suitable hydraulic/size, specific speed and number of stages. Due to the low viscosity, hence minor viscosity correction on a well proven pump characteristic, this task was considered to be quite accurate. No official performance test was conducted for this viscosity. Intermittent start-up (57 cp): With the highest viscosity, the pump was required to start at minimum flow. Power consumption decreases together with flow and would therefore not reach the electrical motor power rating. Initially, the pump torque was considered critical for the electrical motor. However, comparing the pump with the motor torque, it was evident that the margin was satisfactory even when considering the uncertainties related to prediction of pump characteristic for high viscous flow. Torque curves are not presented. To verify the required start-up at viscosity 57 cp a full-scale test was conducted. This was one of the two official test scenarios for this EPC project.
3 Intermittent Duty point, Reduced flow (175 cp): Because of the significantly increased viscosity (in relation to normal operating point), flow, head and efficiency would decrease significantly and the pump would no longer be able to deliver the same flow at the required head of 125 m (41.1 ft), hence the name reduced flow. To verify the required head at reduced flow, the pump characteristic was established through a full-scale viscosity performance test. This was the second of two official test scenarios conducted for this EPC project. Pump Characteristic Viscosity Correction: The Intermittent duty point (Reduced flow) gave the highest power consumption and was decisive for rating the electrical motor. Due to the high viscosity, the uncertainties related to prediction of pump characteristic were evident. Three different published methods were investigated, including both empirical- and loss analysis approach: American National Standard for Centrifugal Pumps, Std. No. ANSI/HI (1994). Empirical. American National Standard for Centrifugal Pumps, Std. No. ANSI/ (1). Empirical. Centrifugal Pumps, 2 nd Ed. by J. F. Gülich (sec. 13.1). Loss Analysis, including empirical coefficients. Note: For ANSI/ (1) the equations for calculating correction coefficients are identical. In Table 1 the calculated viscous correction coefficients are presented for B.E.P. Head and flow coefficients approximately coincide. However, the efficiency coefficient is significantly lower for HI (1994) approach, hence the power is considerably higher. Viscous Correction Results B.E.P Speed [rpm] Density [kg/m 3 ] Density [lb/ft 3 ] Viscosity [cp] SI units Q Visc [m 3 /h] H Visc [m] P Visc [kw] η Visc [%] Water ( kg/m 3 ) HI (1994) (1) Loss Analysis (Centr. Pumps, J.F Gülich) US customary units Q Visc [gal/min] H Visc [ft] P Visc [BHP] η Visc [%] Water (62,4 lb/ft 3 ) HI (1994) (1) Loss Analysis (Centr. Pumps, J.F Gülich) Viscous Correction Coefficients: C Q [-] C H [-] C P [-] C η [-] HI (1994) (1) Loss Analysis (Centr. Pumps, J.F Gülich) Table 1: Comparison of Correction Factors based on HI Correction Factor and Loss Analysis The same observation is done outside the B.E.P, see Figure 2. For the Intermittent Duty point (Reduced flow), the power consumption varied from (see Figure 2): Figure 1: General arrangement of pump test configuration (by courtesy of EUREKA PUMPS AS) 77 kw (133 BHP), HI (1994) 6 kw (831 BHP), Centrifugal Pumps, 2 nd Ed. By J. F. Gülich.
4 Figure 2: Estimated performance curve with corrections for viscosity 175 cp (by courtesy of EUREKA PUMPS AS)
5 This is a variation of approximately %. However it should be emphasized that the loss analysis equations from Centrifugal Pumps, 2 nd Ed. by J. F. Gülich incorporates empirical coefficients for head, flow and efficiency with an allowable variation range (maximum, minimum and mean). By increasing or decreasing these values, so will the correction coefficient, to make it possible for a more- or less conservative approach for predicting viscous pump characteristics. Considering the high viscosity, the large variation in correction coefficients and the fact that a conservative approach was decided to use, ANSI/HI (1994) was the preferred method when rating the electrical motor. It should be noted that this was an older HI version for predicting the pump characteristics for viscous flow. Test results compared with Hydraulic Institute predictions: In addition to test results presentation, a comparison with ANSI/HI (1994) and (1) methods of viscosity correction for pump characteristics is presented. It is simply for discussion and not for validation of the Hydraulic Institute s methods. The loss analysis in Centrifugal Pumps, 2 nd Ed, J. F. Gülich is simply left out to limit the amount of data presented, but also because of the large deviation for the power prediction. TEST LOOP ENGINEERING Test conditions The purpose was to design a test loop that could carry out the official test scope consisting of two main scenarios: 1) Start-up test at high viscosity and minimum flow: Motor was started DOL. Power supply was V, 6 Hz, 3ph, using portable power generators. For this test, oil viscosity was approx. 75 cp at the start-up. Viscosity control was not required after starting. 2) Intermittent Duty point, reduced flow: Motor was started DOL under the same conditions as for 1). For this performance test, the oil viscosity was controlled at about 175 cp. Additional performance tests Internal tests with various viscosities from 48 cp up to 57 cp were also performed in preparation for the official tests. Initially a performance test was conducted using water. The 6 Hz power generator was used during this test. Three additional performance tests at viscosities of 485 cp, 185 cp and 1639 cp were conducted, but with lower rotational speed using the Hz, 3 ph power source from the CETIM s facilities. Test loop design The most important design basis for the test loop was the highly viscous test fluid (more specifically: oil). Thus the pump was put in a closed test loop. The pump was submerged vertically in a caisson integrated in the closed test loop. The loop, including control valves, flow-meter, heat exchanger and so forth was designed according to pump dimensions, flow and capacity. The test loop was equipped with instrumentation and auxiliary systems necessary for meeting the relevant parameter targets. Cooling system selection Designing the cooling system for a viscosity of 175 cp, with a motor power consumption of 78 kw was the main challenge. During the performance test, the purpose was to maintain a stable oil temperature to keep a constant viscosity and comparable running conditions. Water was selected as cooling fluid. CETIM has a 1, m 3 (353,147 ft 3 ) water basin at ambient temperature (typically 64.4 F/ 18 C). A plate heat exchanger was able to meet head losses and cooling requirements. During testing, all the circulated oil went through the heat exchanger. The heat exchanger cooling water was pumped from the water basin at ambient temperature. The oil temperature was then controlled by adjusting the cooling water flow rate using a control valve. The heat exchanger design would influence the selection of test oil significantly, because the temperature difference between the cargo oil and the cooling water had a significant influence on heat exchanger performance. Calculations were based on pump nominal flow rate. Oil selection A mineral oil was selected as it is a Newtonian fluid. For safety reasons, high oil temperatures were avoided. Two viscosity values were required for testing: 57 cp and 175 cp. The viscosity was controlled by the temperature of the fluid. It was necessary to have about 1 C ( F) difference in the oil temperatures to achieve those two different viscosities. Also, the heat exchanger performance required an adequate temperature difference between tank oil and cooling water. This has given a temperature of about 28- C ( F) for 57 cp and about 38- C (.4-14 F) for 175 cp. The ISO VG selected oil had a viscosity of 59 cp at 29.6 C (85.3 F) and 175 cp at 38.1 C (.6 F ). When selecting the type of oil, it was also important to evaluate its density, especially for the start-up test, as required power is directly linked to density. At 57 cp the specified crude oil density for field operation was 936. kg/m 3 (58.4 lb/ft 3, SG of.936). The ISO VG density for 57 cp was 892. kg/m 3 (55.7 lb/ft 3, SG of.892). Prior to the pump test, a specialized laboratory established the oil viscosity and density as function of temperature. A mineral oil with higher density and correct viscosities in this temperature range (28- C/82-14 F) has not been identified. Table 2 presents the density and viscosity variation with temperature for the ISO VG oil that was selected. Temperature Density Viscosity C F kg/m 3 lb/ft 3 cst cp Table 2: ISO VG oil characteristics
6 When the test loop design was frozen the required volume, including all auxiliaries, was 1 m 3 (353 ft 3 ). Instrumentation and control The following equipment was selected to meet the test requirements: A Coriolis flowmeter connected on the discharge line. Control valve(s) on the discharge line to adjust the discharged flow rate, hence establish the performance curve. A heat exchanger to control fluid temperature and maintain constant viscosity of 175 cp during performance test. The flowmeter selection was based on viscous flow rate (Q) up to 1 m 3 /h (4535 USgpm) at 175 cp and the head loss generated, taking into account the pump total head of 95 m at 1 m 3 /h (311.7 ft at 5723 USgpm). The choice was a Coriolis flowmeter, ND2. The uncertainty associated with this measurement at the BEP is ±.57%. The control valve selection was driven by the head loss for the required viscosity (175 & 57 cp) and the maximum flow of 1 m 3 /h (5723 USgpm). Final choice was a Monovar ND control valve. Other valves were also installed in the test loop. However these were only for isolation purposes in case of leakage or for dismantling parts in the test loop. To measure the pump total head (H), pressure tappings were mounted at a distance of 2D from the discharge flange. The measuring sleeve had the same diameter as the pump discharge. Suction pressure was measured at the bottom of the caisson, near the suction bell. Total head was measured by means of pressure transducers fit for highly viscous fluid. The uncertainty associated with the total pump head measurement was lower than 1% at BEP. The head losses in the discharge column are small compared to the total head of 125 m (4 ft) from the pump. Pump rotational speed (N) was measured with a proximity sensor. The pulses from the proximity sensor are counted by an electronic frequency meter with an uncertainty of.3% Pump power input (P) was measured from motor power input and from motor efficiency for each operating point. Electric motor power input was measured following IEC 634 by a three phase power analyzer, using the three watt meters method. The power analyzer also provides voltage and frequency input measurements. Before the run test, the resistance of the supply cables and the stator resistance were measured. Also, a test of the motor under zero load was performed. Therefore, the total magnetic, mechanical losses and Joule s heat losses were accounted for before start-up. Power measurement was corrected with a temperature measurement of the stator resistance. Therefore, the maximum uncertainty associated with the pump power input was about 2.5% giving an overall pump efficiency uncertainty of 2.69% at most. To record the test fluid temperature and check the viscosity a temperature sensor was placed upstream of the test loop caisson. The required voltage, frequency and power ( Volt, 6 Hz, 78 kw/146 BHP) are supplied by a dedicated power generator to meet DOL start requirement for the motor. Due to the frequency used, generators and transformers were rented. The additional tests run at lower speed used the CETIM electrical facilities with a Hz frequency and an input voltage of 3V. Test loop operating procedures and experience feedback The following points have been taken into account in the test loop design. Due to variation in ambient temperature affecting the test oil temperature and viscosity, pre-heating was evaluated. Low temperature/high viscosity would challenge the DOL start-up of the pump due to high power consumption and torque and high temperature/low viscosity would require cooling of the test oil that could be time-consuming. Thus, a special auxiliary loop was installed to heat or to cool the oil in the main test loop. When filling the test loop, ambient temperature was quite high and oil was naturally pre-heated to about 25 C (77 F). To increase oil temperature up to 29.6 C (85.3 F) or 38.1 C (.6 F), the pump was run with Hz, 3V using CETIM electric facilities. The heat exchanger was switched off. While running the pump the oil temperature increased from 25 C (77 F) to required temperature due to dissipated energy in the oil. This alternative method of increasing the temperature turned out to be quite effective. Furthermore, using a variable speed converter for pre-heating the oil would prevent the power consumption exceeding the motor power rating even for very low ambient temperatures/high viscosities, hence power consumptions. The planned auxiliary loop was not used because of ideal weather conditions. Another important point was to have retention vats under the whole test loop in case of leakage. During the design of the test loop, attention was paid to oil expansion with increasing temperature. An expansion tank was installed at an appropriate location in the test loop. Last, but not least, all parts of the test loop and also the pump had to be cleaned for decommissioning. The more viscous the test oil, the harder it was to clean the test loop and equipment. General arrangement drawings and pictures of the test loop are presented in Figures 3 to 6. Figure 3: Test loop general arrangement set-up
7 TEST RESULTS The test results are presented below. It should be noted that two different rotational speeds were used to test the pump and to evaluate the rotational speed effects on the results: 6 Hz leading to 1783 rpm Hz leading to 149 rpm Test results presented below concern: Test performance curves of the pump with water at 6 Hz (Figure 7) Figure 4: Test loop general arrangement set-up side view PUMP PERFORMANCE VISCOSITY RESULTS Project: EPC Topside Application: Vertically Suspended (VS1) Service: Crude Booster Pump Name: CD2-2 Speed [rpm] D2 [mm] Stages Liquid Density [kg/m 3 ] Viscosity [cp] Water Head H [m] 1 8 Efficiency h [%] 6 Figure 5: Auxiliary loop general arrangement set-up 1 Head, Efficiency, Power P [kw] Figure 7: Test performance curves with water at 22 C, 1 cp at 6 Hz Figure 6: Test loop, by courtesy of EUREKA PUMPS AS - CETIM Further results are presented below Cold start with oil (75 cp and lb/ft 3 / 89 kg/m 3, SG of.89 as density) at 6 Hz (Figure8)
8 PUMP PERFORMANCE VISCOSITY RESULTS Project: EPC Topside Application: Vertically Suspended (VS1) Service: Crude Booster Pump Name: CD2-2 Speed [rpm] D2 [mm] Stages Liquid Density [kg/m 3 ] Viscosity [cp] Crude Oil Figure 8: Cold start with oil at 75 cp, 89 kg/m 3, 6Hz The performance characteristics of the pump using various viscosities and rotational speed are then presented. Hydraulic Institute correction factors (ANSI/ (1) (Figure 9) and HI (1994)) apply to the pump tested as the calculated values of the B coefficient from HI is within the applicable range (1<B<). The results from these corrections are plotted alongside the test results. The table below presents a summary of all tests performed including figures and tables presenting the results. (Please note that the table is not a summary of the results.) Speed (rpm)/freq (Hz) 1783 rpm/ 6 Hz 1783 rpm/ 6 Hz 1783 rpm/ 6 Hz 149 rpm/ Hz 149 rpm/ Hz 149 rpm/ Hz Mean viscosity (cp) Objective Figure Table 1 cp Power, H, η vs. Q 7 75 cp Cold start cp Power, H, η vs. Q HI comparison cp Power, H, η vs. Q HI comparison cp Power, H, η vs. Q HI comparison cp Power, H, η vs. Q HI comparison In all tables, BEP was obtained using an interpolation curve, which is a polynomial equation fitted to the test points. The symbols used in the figures present actual measurement points for viscous fluid or HI viscosity corrected points based on water as test fluid represented in Figure 7. Head H [m] Power P [kw] Intermittent Duty (reduced flow) Flow: 97 m 3 /h Head: 125 m Head, Head, HI Head, Efficiency, Efficiency, HI Efficiency, HI Rated/norm. op. Visc: 181 cp Flow: 18 m 3 /h Head: 125 m Figure 9: Test performance curves at cp-6 Hz compared with (1) and HI (1994) predictions (by courtesy of EUREKA PUMPS AS CETIM) Test Result compared with HI Visc. Corr. Calc. at B.E.P Speed [rpm] Density [kg/m 3 ] Density [lb/ft 3 ] Viscosity [cp] SI units Q Visc [m 3 /h] H Visc [m] P Visc [kw] η Visc [%] Water ( kg/m 3 ) HI (1994) ANSI/ (1) Performance Test results (Ref. chart): US customary units Q Visc [gal/min] H Visc [ft] P Visc [BHP] η Visc [%] Water (62,4 lb/ft 3 ) HI (1994) ANSI/ (1) Performance Test results (Ref. chart): Viscous Correction Coefficients: C Q [-] C H [-] C P [-] C η [-] HI (1994) ANSI/ (1) Performance Test results (Ref. chart): Efficiency h [%] Ratio between -& Calc. Values Q Test /Q Calc H Test /H Calc P Test /P Calc η Test /η Calc HI (1994) ANSI/ (1) Table 3 Associated to Figure 9
9 PUMP PERFORMANCE VISCOSITY RESULTS Project: EPC Topside Application: Vertically Suspended (VS1) Service: Crude Booster Pump Name: CD2-2 Speed [rpm] D2 [mm] Stages Liquid Density [kg/m 3 ] Viscosity [cp] Crude Oil PUMP PERFORMANCE VISCOSITY RESULTS Project: EPC Topside Application: Vertically Suspended (VS1) Service: Crude Booster Pump Name: CD2-2 Speed [rpm] D2 [mm] Stages Liquid Density [kg/m 3 ] Viscosity [cp] Crude Oil Head H [m] Efficiency h [%] Head H [m] Efficiency h [%] 15 Head, Head, HI Head, Efficiency, Efficiency, HI Efficiency, Head, Head, HI Head, Efficiency, Efficiency, HI Efficiency, Power P [kw] Power P [kw] HI Figure 1: Test performance curves at 181 cp- Hz compared with -1 and HI (1994) predictions (by courtesy of EUREKA PUMPS AS CETIM) HI Figure 11: Test performance curves at 1639 cp- Hz compared with -1 and HI (1994) predictions (by courtesy of EUREKA PUMPS AS CETIM) Test Result compared with HI Visc. Corr. Calc. at B.E.P Speed [rpm] Density [kg/m 3 ] Density [lb/ft 3 ] Viscosity [cp] SI units QVisc [m 3 /h] HVisc [m] PVisc [kw] η Visc [%] Water ( kg/m 3 ) HI (1994) ANSI/ (1) Performance Test results (Ref. chart): US customary units QVisc [gal/min] HVisc [ft] PVisc [BHP] η Visc [%] Water (62,4 lb/ft 3 ) HI (1994) ANSI/ (1) Performance Test results (Ref. chart): Viscous Correction Coefficients: C Q [-] C H [-] C P [-] C η [-] HI (1994) ANSI/ (1) Performance Test Results: Ratio between -& Calc. Values QTest/QCalc H Test/HCalc P Test/PCalc η Test/η Calc HI (1994) ANSI/ (1) Table 4 Associated to Figure Test Result compared with HI Visc. Corr. Calc. at B.E.P Speed [rpm] Density [kg/m 3 ] Density [lb/ft 3 ] Viscosity [cp] SI units QVisc [m 3 /h] HVisc [m] PVisc [kw] η Visc [%] Water ( kg/m 3 ) HI (1994) ANSI/ (1) Performance Test results (Ref. chart): US customary units QVisc [gal/min] HVisc [ft] PVisc [BHP] η Visc [%] Water (62,4 lb/ft 3 ) HI (1994) ANSI/ (1) Performance Test results (Ref. chart): Viscous Correction Coefficients: C Q [-] C H [-] C P [-] C η [-] HI (1994) ANSI/ (1) Performance Test Results: Ratio between -& Calc. Values QTest/QCalc H Test/HCalc P Test/PCalc η Test/η Calc HI (1994) ANSI/ (1) Table 5 Associated to Figure
10 PUMP PERFORMANCE VISCOSITY RESULTS Project: EPC Topside Application: Vertically Suspended (VS1) Service: Crude Booster Pump Name: CD2-2 Speed [rpm] D2 [mm] Stages Liquid Density [kg/m 3 ] Viscosity [cp] Crude Oil To summarize these test results, Figure 13 is plotted. It gives a comparison at BEP between measured values and HI predictions according to ANSI/ (1) and ANSI/HI (1994) as a function of the viscosity and for a speed of 149 rpm. Head H [m] Power P [kw] Head, Head, HI Head, Efficiency, Efficiency, HI Efficiency, HI Figure 12: Test performance curves at 486 cp- Hz compared with -1 and HI (1994) predictions (by courtesy of EUREKA PUMPS AS CETIM) Test Result compared with HI Visc. Corr. Calc. at B.E.P Speed [rpm] Density [kg/m 3 ] Density [lb/ft 3 ] Viscosity [cp] SI units QVisc [m 3 /h] HVisc [m] PVisc [kw] η Visc [%] Water ( kg/m 3 ) HI (1994) ANSI/ (1) Performance Test results (Ref. chart): US customary units QVisc [gal/min] HVisc [ft] PVisc [BHP] η Visc [%] Water (62,4 lb/ft 3 ) HI (1994) ANSI/ (1) Performance Test results (Ref. chart): Viscous Correction Coefficients: C Q [-] C H [-] C P [-] Cη [-] HI (1994) ANSI/ (1) Performance Test results: Ratio between -& Calc. Values Q Test/Q Calc H Test/H Calc P Test/P Calc η Test/η Calc HI (1994) ANSI/ (1) Table 6 Associated to Figure Efficiency h [%] CORR. COEFF. VARIATION TO VISCOSITY, B.E.P. Project: EPC Topside Application: Vertically Suspended (VS1) Service: Crude Booster Pump Name: CD2-2 Speed [rpm] D2 [mm] Stages Liquid Density [kg/m 3 ] Viscosity [cp] Crude Oil 936 Variable 1. Flow Corr. Coeff. C Q [-] Head Corr. Coeff. CH [-] Eff. Corr. Coeff. Cη[-] Power Corr. Coeff. C P [-] HI Dyn. Visc. µ[cp] HI Dyn. Visc. µ[cp] HI Dyn. Visc. µ[cp] HI Dyn. Visc. µ[cp] Figure 13: Deviation between Test Results and ANSI/ (1) & (1994). Predictions at BEP (% being agreement between tests and predictions) (by courtesy of EUREKA PUMPS AS CETIM) DISCUSSION Intermittent start-up (57 cp) test: Naturally, no performance curve exists as this test is a start-up at minimum flow. However, Figure 8 presents the actual values recorded for the 4 minutes test. The most important point to notice for this test is the actual start-up viscosity of 75 cp. This is significantly higher than the actual requirement of 57 cp. As stated in the Pump & Motor section, the rated torque for this motor was eventually no concern as it is significantly higher than the calculated pump torque. This is also demonstrated by the successful start-up test at 75 cp.
11 Intermittent Duty point, Reduced flow (175 cp) test: With a required head of 125 m (41 ft), the read off flow from the test results in Figure 9 is actually 97 m 3 /h (4271 USgpm). This is 14% higher that the estimated value of 8 m 3 /h (3742 USgpm) from the predicted pump characteristics in Figure 2. This is also indicated in Table 3 when comparing the estimated correction coefficient values (B.E.P.) for flow and head with the actual ones. An important observation in Figure 9 is the actually measured power consumption of 77 kw (133 BHP), just below the rated motor power of 78 kw (146 BHP) and significantly higher than the predicted power from ANSI/ (1). It is therefore reason to believe the specified rated motor power would be insufficient if based on predictions from ANSI/HI (1) or a loss analysis based on J.F. Gülich, see Figure 2. Predicted power from ANSI/HI (1994) is quite accurate compared to the real power consumption. Test results comparison with HI prediction: A clear observation in Figures 9-12 is the over-prediction of efficiency (or under-prediction of power) for ANSI/HI (1). The same consistency is observed for the flow and head that is over- and under- predicted respectively. It results in a flow/head curve below the actual measured curve and an efficiency curve with B.E.P located at higher flow than the actual measured curve. This observation is for both ANSI/ (1) & (1994) and the flow/head curve prediction is almost identical as well. This is also presented by the correction coefficients in Tables 3-6. Furthermore, the very same head and flow prediction is observed for the loss analysis based on J.F. Gülich in Figure 2. However, this loss analysis prediction is limited to a viscosity of 175 cp only. Hence it is unknown if consistent for other viscosities. ANSI/HI (1994) is the oldest prediction method used for comparison, but with a far smaller power/efficiency deviation than ANSI/ (1) and Gülich, particularly for viscosity of 175/185/181 cp, see Figures 2, 9-12 and Tables 1, 3-6. For the real B.E.P flow in Figures 9-1, the power consumption is identical. Furthermore, the B.E.P C p in Tables 3 & 4 is also identical when compared to the real C p based on measured results. Interestingly, these observations are identical for both - and 6 Hz rot. speed and viscosity of 185/181 cp, cf. Figures 9 & 1. Hence, for this particular case it indicates an accurate power prediction when rotational speed varies. Figure 13 presents the same deviations between the predicted and measured flow characteristics as described above but for varying viscosity values. An interesting observation is the C H and C Q increasing accuracy with decreasing viscosity when compared to measured values. However, this is only the case for the viscosity range cp. Above 181 cp the deviation seem to be approx. constant. The C H calculated from the measured values are: C H (486 cp) = 1.2 and C H (181 cp) = 1.4, see Table 4 and Table 6 in conjunction with Figure 13. Surprisingly the measured C H values are above 1 at viscosity equal to- or less than 181 cp. An explanation for this effect could be the reduction in B.E.P flow values when corrected for viscous flow. If this is significant and in combination with low viscous head loss the value C H = H Visc / H Water can be greater than 1. The C P and C η from ANSI/ (1) follow the same curve slope when compared to the measured values. ANSI/HI (1994) does not follow the same gradient, but crosses at viscosity of 181 cp having no deviation at this point compared to the measured value, which was fortunate when deciding the motor rating. Further, the power is under-predicted at viscosity 486 cp and overpredicted at 1639 cp. The deviation is also larger at viscosity 486 cp. The opposite would be expected as the prediction seems to be more inaccurate with higher viscosity. To emphasize, the test results are from an EPC project and are therefore limited. Hence, further work and additional experimental data is highly recommended in order to confirm and explain the above observations, especially for the discrepancies between the measured- and predicted pump characteristics. CONCLUSIONS A full scale high viscosity pump performance test was completed for a 2-stage vertically suspended (VS1) API61 pump. The test scope was part of an ongoing EPC project and exclusively conducted for industrial purposes. Test data presented is for both - and 6 Hz rotational speed and for a viscosity range of 1 to 75 cp. The objective was to simulate real field operation with crude oil and to qualify the pump for the given field conditions and requirements in order to minimize field risks and associated costs. In addition, the laboratory tests were conducted due to published methods uncertainties and limited open literature concerning pump performance in viscous oils. Pump performance viscosity predictions from HI and Gülich are also presented and compared with test results. The aim was to evaluate alternative future approaches in order to improve prediction uncertainties and ultimately reduce the number of tests/test scope in future projects. The comparison is simply for discussion within the industry and not for validation of published methods of pump performance predictions with viscous fluids. Comparison with HI and Gülich s loss analysis shows discrepancies for all performance parameters consisting of flow, head and power/efficiency. A major observation from this paper is the scatter between the power consumption observed in the test results and the results from loss analyses or HI prediction from 1994 and 1. The HI correction from
12 1994 was selected because it was the most conservative power correction when rating the electrical motor. Viscous performance tests will allow optimizing the selection of process equipment, especially for motor sizing for which ANSI/ (1) predictions seems to under-predict the required power. Further tests regarding variation of viscosity, range of flow rate and a systematic variation of the stage number would be required to analyze more precisely the observed discrepancies. In cases where installation cost, maintenance cost and loss of production are critical in financial terms and where the uncertainties regarding performance predictions are high, realistic laboratory testing with real fluids, real operating points and specific design of the pump may be necessary to mitigate the potential risks. To conclude, the testing of the pump performance under realistic conditions was positive. The design of the test loop provided adequate conditions regarding viscosity of fluids to evaluate the pump performance. Both official tests (start-up and intermediate duty) were successful. Important experience regarding building/designing the test stand and the execution of the tests was gained. REFERENCES Hydraulic Institute, ANSI/-1, Effects of Liquid Viscosity on Rotodynamic (Centrifugal and Vertical) Pump Performance ANSI/ Hydraulic Institute, , 1994, Centrifugal Pump Design and Applications J.F. Gülich, 14, Centrifugal Pumps, 2 nd Ed, New York, Springer-Verlag IEC 634, 14, International standard on rotating electrical machine, ACKNOWLEDGEMENTS We would like to thank our customers and end user together with EUREKA PUMPS AS and CETIM teams who have worked on this project. Thanks also to Simen Holler (EUREKA PUMPS), Rune Osmundsen (EUREKA PUMPS), Arne Nilsen (EUREKA PUMPS) and all the suppliers for their support. NOMENCLATURE B =Parameter used in the HI viscosity corrections [-] BEP = Best Efficiency Point D 2 = Impeller outlet diameter ft /m DOL = Direct On Line EPC = Engineering, Procurement, Construction H = Total head ft /m H Visc = Viscous total head ft /m n q = Specific speed n q = N Q.5 / H.75 [-] N = Shaft speed P = Pump shaft input power BHP /kw P Visc = Shaft input power with viscous fluid BHP /kw P w Inp = Pump shaft input power with water BHP /kw Q = Flow rate USgpm /m 3 /h Q Visc = Flow rate with viscous fluid USgpm /m 3 /h Re = Reynolds number Re= ωr 2 2 /ν [-] r 2 = Impeller outlet radius ft /m SG = Specific gravity η = Pump efficiency [-] η Visc = Pump efficiency with viscous fluid [-] µ = Dynamic viscosity cp ω = Angular velocity of shaft rpm
CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES
CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES 4.0 PUMP CLASSES Pumps may be classified in two general types, dynamic and positive displacement. Positive displacement pumps
Chapter 3.5: Fans and Blowers
Part I: Objective type questions and answers Chapter 3.5: Fans and Blowers 1. The parameter used by ASME to define fans, blowers and compressors is a) Fan ration b) Specific ratio c) Blade ratio d) Twist
Experiment 3 Pipe Friction
EML 316L Experiment 3 Pipe Friction Laboratory Manual Mechanical and Materials Engineering Department College of Engineering FLORIDA INTERNATIONAL UNIVERSITY Nomenclature Symbol Description Unit A cross-sectional
Centrifugal Fans and Pumps are sized to meet the maximum
Fans and Pumps are sized to meet the maximum flow rate required by the system. System conditions frequently require reducing the flow rate. Throttling and bypass devices dampers and valves are installed
Grant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme
Grant Agreement No. 228296 SFERA Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME Capacities Specific Programme Research Infrastructures Integrating Activity - Combination of
The conditions below apply to the curves shown on the following pages.
GENERAL INFORMATION STAINLESS STEEL, SILVERLINE, EVERGREEN & GOLDLINE SERIES PERFORMANCE CURVE CONDITIONS The conditions below apply to the curves shown on the following pages. a. The Performance curves
CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.
CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc. 1 Centrifugal Pump- Definition Centrifugal Pump can be defined as a mechanical device used to transfer liquid of various types. As
HEAVY OIL FLOW MEASUREMENT CHALLENGES
HEAVY OIL FLOW MEASUREMENT CHALLENGES 1 INTRODUCTION The vast majority of the world s remaining oil reserves are categorised as heavy / unconventional oils (high viscosity). Due to diminishing conventional
1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING
1115 4G SERIES GOVERNOR with 4-20 ma ANALOGUE & DIGITAL SPEED SETTING PO Box 28, 9300AA Roden, The Netherlands Tel: +31 505019888 Fax: +31 505013618 E-mail: [email protected] 1115 4G
Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.
GE Measurement & Control Solutions Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically
SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
Experiment # 3: Pipe Flow
ME 05 Mechanical Engineering Lab Page ME 05 Mechanical Engineering Laboratory Spring Quarter 00 Experiment # 3: Pipe Flow Objectives: a) Calibrate a pressure transducer and two different flowmeters (paddlewheel
Series description: Wilo-Drain TC 40
Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
Conlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).
HYDRAULIC MACHINES Used to convert between hydraulic and mechanical energies. Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic
Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29
_02 A centrifugal with a 12 in. diameter impeller requires a power input of 60 hp when the flowrate is 3200 gpm against a 60 ft head. The impeller is changed to one with a 10 in. diameter. Determine the
Variable Displacement Pump AA10VSO
Variable Displacement Pump AA10VSO Series 31, Industrial Model, for Open Circuits Axial piston, swashplate design Brueninghaus Hydromatik Sizes 28...140 Nominal pressure 4000 psi Peak pressure 5100 psi
Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids
Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids Dr. J. M. Meyers Dr. D. G. Fletcher Dr. Y. Dubief 1. Introduction Last lab you investigated flow loss in a pipe due to the roughness
Pump Formulas Imperial and SI Units
Pump Formulas Imperial and Pressure to Head H = head, ft P = pressure, psi H = head, m P = pressure, bar Mass Flow to Volumetric Flow ṁ = mass flow, lbm/h ρ = fluid density, lbm/ft 3 ṁ = mass flow, kg/h
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
Flygt N-Pumps 3085, 3102 & 3127. For reliable and efficient wastewater handling
Flygt N-Pumps 3085, 3102 & 3127 For reliable and efficient wastewater handling The Concept Flygt N-Pump series Reduced pumping efficiency, high energy and maintenance costs shouldn t be a fact of life
Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps
Pump ED 101 Positive Displacement Pumps Part I Reciprocating Pumps Joe Evans, Ph.D http://www.pumped101.com There are many pump designs that fall into the positive displacement category but, for the most
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
FLOW MEASUREMENT 2001 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER
FLOW MEASUREMENT 200 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER Dr D G Stewart, NEL Dr M Reader-Harris, NEL Dr R J W Peters, McCrometer Inc INTRODUCTION The V-Cone
A TEST RIG FOR TESTING HIGH PRESSURE CENTRIFUGAL COMPRESSORS MODEL STAGES AT HIGH REYNOLDS NUMBER
A TEST RIG FOR TESTING HIGH PRESSURE CENTRIFUGAL COMPRESSORS MODEL STAGES AT HIGH REYNOLDS NUMBER P. NAVA, M.PROFETI, M. GIACHI, F.SARRI GE-NUOVO PIGNONE G.P.MANFRIDA UNIVERSITY OF FLORENCE Italia Presented
Series TMM Axial Piston Motor. Technical Information
Series TMM Axial Piston Motor Technical Information General Description GENERAL DESCRIPTION These motors are designed primarily to be combined with other products in closed circuit systems to transfer
International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No.161-166, March-April 2015
International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No.161-166, March-April 2015 http://www.mnkjournals.com/ijlrst.htm ISSN (Online):2278-5299 EXPERIMENTAL STUDY
Manufacturing Equipment Modeling
QUESTION 1 For a linear axis actuated by an electric motor complete the following: a. Derive a differential equation for the linear axis velocity assuming viscous friction acts on the DC motor shaft, leadscrew,
Understanding the Flo-Dar Flow Measuring System
Understanding the Flo-Dar Flow Measuring System Independent tests verify non-contact flowmeter is highly accurate under both open channel and surcharge conditions TM Flo-Dar is the only non-contact open
SJT / SJM / SJP Large Vertical Pumps
SJT / SJM / SJP Large Vertical Pumps The Heart of Your Process SJT, SJM, SJP Large Vertical Pumps Product Overview SJT Turbine Ns 1800 < 5000 nq 35 < 110 SJM Mixed Flow Ns 5800 < 8300 nq 113 < 161 SJP
Vertical selfpriming Side-Channel Pumps Type WPV
Vertical selfpriming Side-Channel Pumps Type WPV FIELD OF APPLICATION The side-channel pumps are selfpriming and operate more economically (better efficiency) than normal centrifugal pumps when handling
ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES
ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES by Kazuhiro Takeda Research Manager, Research and Development Center and Kengo Hirano Instrument and Control Engineer,
300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
INVESTIGATION OF FALLING BALL VISCOMETRY AND ITS ACCURACY GROUP R1 Evelyn Chou, Julia Glaser, Bella Goyal, Sherri Wykosky
INVESTIGATION OF FALLING BALL VISCOMETRY AND ITS ACCURACY GROUP R1 Evelyn Chou, Julia Glaser, Bella Goyal, Sherri Wykosky ABSTRACT: A falling ball viscometer and its associated equations were studied in
MATLAB AS A PROTOTYPING TOOL FOR HYDRONIC NETWORKS BALANCING
MATLAB AS A PROTOTYPING TOOL FOR HYDRONIC NETWORKS BALANCING J. Pekař, P. Trnka, V. Havlena* Abstract The objective of this note is to describe the prototyping stage of development of a system that is
The Piping System Model a New Life Cycle Document. Elements of the Piping System Model
Piping System Model as a Life Cycle Document White Paper Introduction When designing piping systems, a variety of documents are created providing the details necessary to design, purchase, build, and test
CRK 2-130 A-W-A-BUBV 85805906
GRUNDFOS DATA BOOKLET CRK 2-13 A-W-A-BUBV 858596 Grundfos Pump 497113 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crk2/497113/crk-2-13-13-a-w-a-auuv.html
Technical Specification. Generating Set with Waukesha engine burning natural gas
Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the
Radial piston pumps type R and RG
Radial piston pumps type R and RG Operating pressure p max = 700 bar Delivery flow Q max = 91.2 lpm (at 1450 rpm) Geometric displacement V g max = 64.2 cm 3 /rev. 1. General Motor pumps and hydraulic power
The performance of centrifugal pumps when pumping ultra-viscous paste slurries
The performance of centrifugal pumps when pumping ultra-viscous paste slurries by J. Crawford*, F. van Sittert, and M. van der Walt Synopsis Significant advances have been made in the design of centrifugal
Flygt 3068, 50Hz. Technical Specification
Flygt 3068, 50Hz Technical Specification Table of Contents Table of Contents B-pump...2 Product description...2 Motor rating and performance curves...4 C-pump...6 Product description...6 Motor rating
Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.
ASGMT / Averaging Pitot Tube Flow Measurement Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. Averaging Pitot Tube Meters Introduction
BSM MOTOR DRIVEN CENTRIFUGAL PUMPS
PRINCIPLE OF OPERATION A hydraulically and dynamically balanced impeller with raised vane sections discharges liquid as a result of the centrifugal force developed in rotation. The head developed is entirely
AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL
FUEL CONSUMPTION MEASUREMENT AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL Description The combination of AVL Fuel Mass Flow Meter and AVL Fuel Temperature Control is a high precise and continuous
T U R B I N E G A S M E T E R
TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
Pump Selection and Sizing (ENGINEERING DESIGN GUIDELINE)
Guidelines for Processing Plant Page : 1 of 51 Rev 01 Feb 2007 Rev 02 Feb 2009 Rev 03 KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru. (ENGINEERING DESIGN GUIDELINE)
Methodology for Liquid Ultrasonic Flow Measurement within the Laminar to Turbulent Transitional Zone
Methodology for Liquid Ultrasonic Flow Measurement within the Laminar to Turbulent Transitional Zone Dave Seiler Daniel Measurement and Control March 25, 2014 Heavy Oil Definition!!!!the API classifies
PUMP VIBRATION STANDARDS GUIDELINES
EUROPEAN ASSOCIATION OF PUMP MANUFACTURERS ASSOCIATION EUROPÉENNE DES CONSTRUCTEURS DE POMPES EUROPÄISCHE VEREINIGUNG DER PUMPENHERSTELLER PUMP VIBRATION STANDARDS GUIDELINES First edition - 15 July 2013
BaseCal 3. BaseCal, the web-based performance calculation tool for Diaphragm Seals
BaseCal 3 BaseCal, the web-based performance calculation tool for Diaphragm Seals BaseCal: the diaphragm seal performance calculation tool BaseCal is the web-based performance calculation tool for diaphragm
Model 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
Multistage high-pressure multistage centrifugal pumps
Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,
Entrained Gas Diagnostic with Intelligent Differential Pressure Transmitter
January Page Entrained Gas Diagnostic with Intelligent Differential Pressure Transmitter Dave Wehrs - Director, Pressure Engineering Andrew Klosinski - Application Engineer, Pressure Diagnostics Emerson
191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES
191: Calibration and Standards in Measurement Richard Paton National Engineering Laboratory, Scotland, UK 1 General Principles 1 2 Gravimetric Calibration of Liquid meters 2 3 Volumetric Calibration of
Turbine Flowmeters for Gas Applications
Turbine Flowmeters for Gas Applications Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because
Machine Design II Prof. K.Gopinath & Prof. M.M.Mayuram. Module 2 - GEARS. Lecture 17 DESIGN OF GEARBOX
Module 2 - GEARS Lecture 17 DESIGN OF GEARBOX Contents 17.1 Commercial gearboxes 17.2 Gearbox design. 17.1 COMMERCIAL GEARBOXES Various commercial gearbox designs are depicted in Fig. 17.1 to 17.10. These
THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS
4" SUBMERSIBLE PUMPS
4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant
RPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS 426 2.98 23.01
SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS RPT SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +4 581 661 111, fax: +4 581 602 587 Email: [email protected] 426
CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ
GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html
Max. Head (m) LVR3-7-220V 3 32 5 44 0,55 10 50Hz ~ 220 V Oval Flange G1. LVR3-7-380V 3 32 5 44 0,55 10 50Hz ~ 380 V Oval Flange G1
Description NordicFlow s keep the system pressurized during normal conditions and prevent unnecessary activation of the main pump. They have compact design, high efficiency, low noise, reliable sealing
C18 ACERT Fire Pump Tier 3 448 bkw/600 bhp @ 1750 rpm
CATERPILLAR ENGINE SPECIFICATIONS I-6, 4-Stroke-Cycle Diesel Bore...145.0 mm (5.71 in) Stroke...183.0 mm (7.2 in) Displacement... 18.1 L (1,104.53 in3) Aspiration...Turbocharged Aftercooled Compression
Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.
SK Series Piston Types TYPE 2 pplication: Low-friction design for higher piston speeds, slow movements without stick-slip effect and high number of actuations (millions). ctual cycles achieved will vary
CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html
Brush DC Motor Basics. by Simon Pata Business Unit Manager, Brushless DC
thinkmotion Brush DC Motor Basics by Simon Pata Business Unit Manager, Brushless DC Ironless DC Motor Basics Technical Note Brushed DC ironless motors are found in a large variety of products and applications
QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems
The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system
CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100
CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL
Electric Motors and Drives
EML 2322L MAE Design and Manufacturing Laboratory Electric Motors and Drives To calculate the peak power and torque produced by an electric motor, you will need to know the following: Motor supply voltage,
Water hammering in fire fighting installation
Water hammering in fire fighting installation Forward One of major problems raised in the fire fighting network installed at Pioneer company for pharmaceutical industry /Sulaymania was the high water hammering
WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100
WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.
PUMP AND MOTOR DIVISION
INSTALLATION MANUAL SERIES P2 and P3 MOBILE PISTON PUMP 1 Check model code / compare with your paper work Nameplate of the pump Ordering / Sales Acknowledgement 2 Check rotation of the pump Clockwise rotation
Correcting a Coriolis Meter for Two Phase Oil & Gas Flow
Correcting a Coriolis Meter for Two Phase Oil & Gas Flow Chris Mills, NEL 1 INTRODUCTION In the oil & gas industry, the requirement for flow measurement of two phase oil and gas flow is prevalent. This
Mixing in the process industry: Chemicals Food Pharmaceuticals Paper Polymers Minerals Environmental. Chemical Industry:
Mixing Notes: Chapter 19 Robert P. Hesketh Mixing in the process industry: Chemicals Food Pharmaceuticals Paper Polymers Minerals Environmental Chemical Industry: Paints and Coatings Synthetic Rubbers
Chapter 11 SERVO VALVES. Fluid Power Circuits and Controls, John S.Cundiff, 2001
Chapter 11 SERVO VALVES Fluid Power Circuits and Controls, John S.Cundiff, 2001 Servo valves were developed to facilitate the adjustment of fluid flow based on the changes in the load motion. 1 Typical
O-I DUBI PLANT FANS Quotation Spec Data & Specifications
TECHNICAL DATA O-I DUBI PLANT FANS Quotation Spec Data & Specifications 1 page for the global informations + 12 pages for the fans data Revision 2 end april Global informations: These fans are a replacement
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business
THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT
THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT Kazuto Otakane, Tokyo Gas Co., Ltd Katsuhito Sakai, Tokyo Gas Co., Ltd Minoru Seto, Tokyo Gas Co., Ltd 1. INTRODUCTION Tokyo Gas s new gas meter,
Application Information
Moog Components Group manufactures a comprehensive line of brush-type and brushless motors, as well as brushless controllers. The purpose of this document is to provide a guide for the selection and application
MEASUREMENT OF VISCOSITY OF LIQUIDS BY THE STOKE S METHOD
130 Experiment-366 F MEASUREMENT OF VISCOSITY OF LIQUIDS BY THE STOKE S METHOD Jeethendra Kumar P K, Ajeya PadmaJeeth and Santhosh K KamalJeeth Instrumentation & Service Unit, No-610, Tata Nagar, Bengaluru-560092.
Series DFMT Digital Paddlewheel Flowmeter
Series DFMT Digital Paddlewheel Flowmeter Bulletin F-DFMT Specifications - Installation Operating Instructions -/8 [00] -/ [8] -/8 [00] A The Series DFMT Digital Paddlewheel Flow Transmitter provides instantaneous
Testing methods applicable to refrigeration components and systems
Testing methods applicable to refrigeration components and systems Sylvain Quoilin (1)*, Cristian Cuevas (2), Vladut Teodorese (1), Vincent Lemort (1), Jules Hannay (1) and Jean Lebrun (1) (1) University
A10VSO Nominal size 18 see RD 92712 A10VSO Nominal size 28...140 see RD 92711
A10VO Nominal size 18 see RD 92712 A10VO Nominal size 28...140 see RD 92711 The variable displacement axial piston pump A10VO in swashplate design was designed for hydrostatic drives in open circuits.
MEMBRANE VACUUM MINI PUMPS
MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free
Fire Pump Plan Review March 2010
Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:
VISCOSITY OF A LIQUID. To determine the viscosity of a lubricating oil. Time permitting, the temperature variation of viscosity can also be studied.
VISCOSITY OF A LIQUID August 19, 004 OBJECTIVE: EQUIPMENT: To determine the viscosity of a lubricating oil. Time permitting, the temperature variation of viscosity can also be studied. Viscosity apparatus
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB
Non-invasive CLAMP-ON ultrasonic flowmeter for liquids
Non-invasive CLAMP-ON ultrasonic flowmeter for liquids Model CU100: non-invasive installation flowmeter, with transducers installed outside the pipe Installation in horizontal or vertical pipe Easy and
The Professional Choice. LDC With DC motor. OLAER LDC optimized for mobile use
The Professional Choice LDC With DC motor OLAER LDC optimized for mobile use Olaer is a global player specialising in innovative, efficient system solutions for temperature optimisation and energy storage.
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 26 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES
CONTROL VALVE PRESSURE DROP AND SIZING
CONTENT Chapter Description Page I Purpose of Control Valve II Type and Main Components of Control Valve 3 III Power 5 IV. Pressure Drop Across Control Valve 7 V. Symbols and Units 10 VI. Unit Conversion
Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II
Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II 1 For your safety Table of Contents 1 For your safety... 3 1.1 About this manual... 3 1.2 Designated use... 3 1.3 Qualification
Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.
Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power
Flow Measurement. Reference - Flow Measurement FUNDAMENTALS. ρ = fluid density (lb/ft3 or kg/m3)
Flow Measurement FUDAMETALS Flowmetering terms can often seem cryptic Here are definitions of some of the most commonly used ACCURACY Accuracy is a quantity defining the limit that errs will not exceed
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology HWEA 2011 Conference Craig S. Johnson Presentation Overview Introduction Aeration Air & Digester gas challenges Gas flow metering
The Effect of Forced Air Cooling on Heat Sink Thermal Ratings
zpero 1 The Effect of Forced Air Cooling on Heat Sink Thermal Ratings By Paul Bachman, Fellow Engineer & Ronnie Haiduk, Applications Engineer, Crydom, Inc. ABSTRACT A heat sink s ability to dissipate thermal
OJ L 191, 23.7.2009, p. 26. OJ L 2, 7.1.2014, p. 1.
Table of Contents 1. Purpose of the guidelines and disclaimer... 2 1.1. The Regulations... 2 2. Scope... 2 3. Historic developments... 4 4. Scope and Requirements... 5 4.1. Scope... 5 4.2. Requirements...