1 Philips M8001A and M8002A Data Sheet IntelliVue Patient Monitor MP20/MP20 Junior/MP30 The MP20/MP20 Junior/MP30 portable patient monitors are compact in size, ergonomic, and modular in design. They share a common user interface and technological platform with the Philips IntelliVue MP40 and MP50 patient monitors. The monitors can be connected to Philips measurement servers and server extensions to extend their functionality with plug-and-play convenience. The monitors are highly customizable. For the MP20/MP30 models, dedicated configurations are available for the anesthesia, critical and cardiac, and neonatal care environments. For the MP20 Junior dedicated configurations for the critical and neonatal care environments are available. The IntelliVue series offers a complete monitoring solution that is flexible and modular, designed to suit a broad spectrum of monitoring needs. Measurement Features ECG monitoring using any combination of three to 10 electrodes. 12-lead ECG monitoring with five electrodes using the EASI method or with 10 electrodes using the conventional method. Multi-lead arrhythmia and ST segment analysis at the bedside on all available leads. The Hemodynamic Measurement Server Extension extends your measurement capability by adding a temperature and a pressure and an additional pressure or temperature measurement plus optional cardiac output (not MP20 Junior). FAST SpO 2 for accurate performance even with low perfusion. The monitor can operate using battery power for up to five hours, to let you safely and easily monitor patients during in-hospital transfer.
2 Usability Features Intuitive user interface. Simple menu hierarchy gives fast access to all basic monitoring tasks. Patient data management with tabular and graphic trends. Ventilation, hemodynamic, and oxygenation calculations. Settings Profiles for rapid case turnover. Patented automatic alarm limits help clinicians provide care more efficiently. Neonatal Event Review keeps a record of rapidly changing condition of neonatal patients 1. Bed-to-bed overview provides clinicians with an overview of all the patient beds in their care 1. Choice of input devices: touchscreen (MP30 only), navigation point, mouse, trackball, remote SpeedPoint or keyboard. 10.4" TFT flat panel display with SVGA resolution, wide viewing angle, large numerics, permanently visible alarm limits, and up to 4 realtime waves (3 waves for MP20 Junior). Intended Use The monitors are intended to be used for monitoring, recording, and alarming of multiple physiological parameters of adults, pediatrics, and neonates in health care facilities. The devices are to be used by trained health care professionals. The monitors are intended for use in health care facilities and also for use in transport situations within the hospital setting. The monitors are for single patient use only. They are not intended for home use. Rx only: U.S. Federal Law restricts this device to use by or on the order of a physician. Not a therapeutic device. ST segment monitoring is intended for use with adult patients only and is not clinically validated for use with neonatal and pediatric patients. The ECG measurement is intended to be used for diagnostic recording of rhythm and detailed morphology of complex cardiac complexes (according to AAMI EC 11). standalone or networked solution (not MP20 Junior). Upgradability The MP20/MP30 monitors modular design allows new capabilities to be added in the future as your monitoring requirements evolve. This upgradability gives the security of knowing that the monitors can be enhanced and updated as practices and technologies advance, and it protects long-term investments. 1 Main Components Display The monitors have color LCD TFT displays with a wide viewing angle, providing high resolution waveform and data presentation. The display, processing unit, and power supply are integrated into one device. User Interface The user interface is designed for fast and intuitive operation. The color graphical user interface ensures that clinicians quickly feel at ease using the monitor. SmartKeys with intuitive icons allow monitoring tasks to be performed quickly and easily, directly on the monitor screen. Waves and numerics are color-coded. The monitors display up to four measurement waves simultaneously. For 12-lead ECG monitoring they can display 12 real-time ECG waves, with a rhythm strip and all ST values. Touchscreen Operation The MP30 monitor is supplied with a touchscreen display with a resistive touch surface. Input Devices Supported input devices include the navigation point and PS/2 compatible off-the-shelf computer accessories such as mouse or trackball 1. Modularity The monitor s functionality can be extended by connecting Philips multi-measurement server and measurement server extensions. It is available as a 1.Not MP20 Junior 2
3 NavigationPoint Multi-Measurement Server (MMS) The integrated navigation point is the primary input device for the MP20 and MP20 Junior and supports the touchscreen for MP30. Its dial can be rotated to enable navigation across the monitor screen. A tactile resistance at every step gives the user control over cursor movement. The navigation point has four hardkeys: Mouse Any specified PS/2 mouse or trackball may be used for data entry. 1 Simulated Keyboard Integrated Navigation Point Silence key to acknowledge all active alarms or switch alarm indicators on or off Alarms key to pause alarm indicators or switch alarm indicators on or off Back key to take the user back from a sub menu to a main menu Main Screen key to take the user from any window to the main screen If alpha or numeric data entry is required, for example to enter patient demographics, an on-screen keyboard will automatically appear on the screen. MMS with measurement extension The M3001A Multi-Measurement Server (MMS) can be connected without cables to the rear of the MP20/30. It sends measurement waves and numerics to the monitor screen and generates alarms and INOPs. Up to eight hours of patient trends are stored in the MMS, as well as patient demographic details. The MMS provides measurement data for Electrocardiogram (ECG)/Arrhythmia, Respiration, Oxygen Saturation of Arterial Blood (SpO 2 ), Non- Invasive Blood Pressure (NBP), and Invasive Pressure or Temperature. It features 12-lead ECG capability, multi-lead arrhythmia, and 12-lead ST analysis. Measurement Server Extensions A Measurement Server Extension can optionally be slotted onto the Multi-Measurement Server to add: M3016A: integrated mainstream CO 2 (optional) and Invasive Blood Pressure or Temperature. M3015A: Microstream CO 2 2, and Invasive Blood Pressure/Temperature (optional). M3012A: Temperature and Invasive Blood Pressure and an additional Invasive Blood Pressure or Temperature measurement, optionally with Cardiac Output and Continuous Cardiac Output. 1 1.Not MP20 Junior 2.Microstream is a registered trademark of Oridion Systems Ltd. 3
4 Application Features Critical and Cardiac Care Features M3012A hemodynamic measurement server extension Remote Alarm Device 1 The Remote Alarm Device can be connected to an external device interface connection on the monitor and mounted in a conspicuous position to improve the visibility of alarm signals generated by the monitor. The device has three optical alarm indicators, an integrated speaker to transmit audible alarm signals and an On/Standby key to remotely switch the monitor on or put it into standby. Remote SpeedPoint 1 Remote Alarm Device The remote SpeedPoint can also be connected to an external device interface connection on the monitor. It combines joystick with dial control and enables full two-dimensional navigation across the monitor screen. A tactile resistance at every step gives the user control over cursor movement. The monitor performs multi-lead arrhythmia detection analysis on the patient s ECG waveform at the bedside. It analyzes for ventricular arrhythmias, calculates heart rate, and generates alarms, including asystole, bradycardia, and ventricular fibrillation. Up to 12 leads of ST segment analysis can be performed on adult patients at the bedside, measuring ST segment elevation and depression and generating alarms and events. The user can trend ST changes, set high and low alarm limits, and set both ST and isoelectric measurement points. Using ST Snippets, one-second wave segments can be compared with a baseline segment for each measured ST lead. 12-lead ECG data can be measured, using either the EASI placement method with five standard electrodes (not MP20 Junior) or conventional electrode placement with 10 electrodes realtime ECG waveforms can be displayed simultaneously. FAST-SpO2, using Fourier Artifact Suppression Technology, performs accurately even in cases with low perfusion. Choice of Microstream and mainstream CO 2 monitoring for high quality measurements with intubated and non-intubated patients. A choice of cardiac output measurements 1 using the right-heart thermodilution method and continuous cardiac output measurements with advanced hemodynamic assessment provided using the PiCCO TM method without a pulmonary catheter. 3 Clinical calculations enable stored and manually entered data to be used to perform hemodynamic, ventilation and oxygenation calculations. Calculated data is displayed in both indexed and non-indexed format. The optional Drug Calculator 1 helps you to manage intravenous (IV) drug infusions by calculating drug dose, rate, amount, volume, concentration, and standardized rate. Mounting The mounting options available enable flexible, space saving placement of the monitors for an ergonomic work space. 1.Not MP20 Junior 2.EASI-derived 12-lead ECGs and their measurements are approximations to conventional 12-lead ECGs. As the 12-lead ECG derived with EASI is not exactly identical to the 12-lead conventional ECG obtained from an electrocardiograph, it should not be used for diagnostic purposes. 3.PiCCO TM is a trademark of Pulsion Medical Systems AG. 4
5 Anesthesia Features The Essential Gas Module (EGM) measures and displays waves and numerics for 3 respiratory gases and one agent. Screens provide flexible viewing of patient information during different procedures or phases of an anesthesia case. Neonatal Monitoring Features 1 The optional OxyCRG screen provides a simultaneous presentation of up to three trends: beat-to-beat heart rate (btbhr) an oxygenation measurement trend compressed respiration wave. This customized display gives clinicians a convenient overview of the neonatal patient s most important vital signs, helping them to identify significant events. Continuous OxyCRG recordings can be made on the built-in recorder, and reports can be printed on locally or centrally-connected printers. Neonatal Event Review (NER) is optimized for monitoring neonatal patients. For each event, an episode of four minutes of data sampled four times a second is stored, to help you keep a record of the rapidly-changing condition of neonatal patients. Combi-events correlate apnea events with bradycardia and/or desaturations. Ease of Use Screen layouts are easily adjustable, allowing flexible display of measurement information. Temperature, height, and weight can be configured either in metric or imperial units. Pressure measurements can be displayed in kpa or mmhg. Gases can be displayed in kpa, mmhg. Trends The trend database stores patientdata from up to 16 measurement numerics. The measurement information can be sampled every 12 seconds, one minute, or five minutes, and stored for a period ranging from four to 48 hours. Transport Features The monitors portable design means they can be used for in-hospital transport: a monitor, combined with an MMS and battery (optional for MP20 and MP30), weighs less than 6 kg. 1.Not MP20 Junior The monitors can operate using battery power for up to five hours, to let you safely and easily monitor patients during procedures or in-hospital transfer. The transition from bedside monitoring to transport is smooth and easy, with no need to disconnect patient cables or adjust any measurement or monitor settings. The monitor s network capability means that it is ready for use as an integrated part of the hospital system. 1 Specially-designed mounting solutions let you quickly disconnect the monitor for transport and reconnect to the mount after transport. The Universal Admit, Discharge and Transfer (ADT) feature means that all ADT information is shared between the networked monitor and the Information Center. Information need only be entered once. 1 Patients can be transferred by disconnecting the MMS from a monitor, and then reconnecting it at a new monitor. Patient demographics are stored in the MMS, so they do not have to be re-entered at the new monitor. Patient Data Documentation An extensive range of Patient Reports can be printed: Event Review and Episode Reports OxyCRG Reports 1 12-lead ECG Reports Alarm Limit Reports Vital Signs Graphic Trends Cardiac Output Reports 1 Wedge Procedure Reports 1 Calculations Reports 1 Drug Calculator Reports 1 Realtime Wave Reports Report templates can be defined in advance, enabling print-outs tailored to each hospital s specific requirements to be started quickly. Reports can be printed on locally or centrallyconnected printers, and they can be initiated manually or automatically at user-defined intervals. Alarms The alarm system can be configured to present either the traditional HP/Agilent/Philips alarm sounds or sounds compliant with the draft ISO/ IEC Standard. 5
6 Alarm limits are permanently visible on the main screen. The Alarm Limits page provides a graphic depiction of alarm limits in relation to the currently monitored measurement values and lets you adjust alarm limits. It also lets you preview wide and narrow automatic alarm limits before you apply them. When an alarm limit is exceeded, it is signalled by the monitor in the following ways: an alarm tone sounds, graded according to severity an alarm message is shown on the screen, colorcoded according to severity the numeric of the alarming measurement flashes on the screen alarm lamps flash for red and yellow alarms and are illuminated for technical INOPs the Remote Alarm Device 1 signals the alarm visibly and audibly. If the monitor is connected via a network to a central monitoring station, alarming is simultaneous at the monitor and at the Information Center. The nurse call relay 1 has active open and closed contacts and a user-definable delay time. Alarms are graded and prioritized according to severity: Red Alarms*** identify a potentially life threatening situation for a patient. Yellow Alarms** indicate conditions violating preset vital signs limits. Technical Alarms (INOPS) are triggered by signal quality problems, equipment malfunction or equipment disconnect. The Audio off/pause Alarms function (equivalent to Silence/Suspend with previous monitor generations) allows the user to switch off alarm tones with one touch or click while retaining visual alarm messages. All alarms can be paused indefinitely or for a period of one, two, three, five, or 10 minutes. Alarm strip recordings are available on the built-in recorder or on a centrally-connected recorder 1. Patented automatic alarm limits automatically adapt the alarm limits to the patient s currently measured vital signs within a safe margin defined individually for each patient. Visual and/or audible latching and non-latching alarm handling is available. 1.Not MP20 Junior Profiles Profiles are predefined configuration settings for Screens, measurement settings, and monitor properties. Each Profile can be designed for a specific application area and patient category, for example OR adult, or ICU neonatal. Profiles enable a quick reaction to patient and care location changes: activating a Profile with a particular patient category (Adult, Pediatric or Neonatal) automatically applies suitable alarm and safety limits and saves time usually spent carrying out a complete set-up procedure. Profiles can be created directly on the monitor or remotely on a personal computer and transferred to the monitor using the Support Tool. A selection of Profiles for common monitoring situations is provided with the monitor. These profiles can be changed, added to, renamed, or deleted. Networking Capabilities 1 The monitor can operate as part of a wired or wireless hospital network system, using the Philips IntelliVue Clinical Network interface. Other Bed Overview Capability 1 The alarm status of beds in the same Care Group on the hospital network can be permanently displayed on the screen of each monitor in the Care Group. The user can also view measurement data from all other monitors connected to the hospital network. Clinical Calculation Set The clinical calculation set consists of: Hemodynamic, Oxygenation, and Ventilation calculations. Hemodynamic Calculations: Cardiac Index (C.I.) and Continuous Cardiac Index (C.C.I.) Stroke Volume (SV) Stroke Index (SI) Systemic Vascular Resistance (SVR) Systemic Vascular Resistance Index (SVRI) Pulmonary Vascular Resistance (PVR) Pulmonary Vascular Resistance Index (PVRI) Left Cardiac Work (LCW) Left Cardiac Work Index (LCWI) Left Ventricular Stroke Work (LVSW) Left Ventricular Stroke Work Index (LVSWI) Right Cardiac Work (RCW) Right Cardiac Work Index (RCWI) Right Ventricular Stroke Work (RVSW) 6
7 Right Ventricular Stroke Work Index (RVSWI) Extra Vascular Lung Water Index (EVLWI) 1 Intrathoracic Blood Volume Index (ITBVI) Global End Diastolic Volume Index (GEDVI) Oxygenation Calculations: Arterial Oxygen Content (CaO 2 ) Venous Oxygen Content (CvO 2 ) Arteriovenous Oxygen Content (avdo 2 ) Oxygen Availability Index (O 2 AVI) Oxygen Consumption (VO 2 ) Oxygen Consumption Index (VO 2 I) Oxygen Extraction Ratio (O 2 ER) Alveolar-Arterial Oxygen Difference (AaDO 2 ) Percent Arteriovenous Shunt (Qs/Qt) Ventilation Calculations: Minute Volume (MINVOL) Compliance (COMP) Dead Space (Vd) Dead Space/Tidal Volume Ratio (Vd/TV) Alveolar Ventilation (ALVENT) Wireless Network (optional) 2 The monitor can function within a wireless infrastructure based on a Frequency Hopping Spread Spectrum (FHSS) radio in the 2.4 GHz band (ISM). Additional components are required to complete the system. Please refer to the M3185A IntelliVue Clinical Network Technical Data Sheet for further information. Service Features The Support Tool helps technical personnel to carry out configuration, upgrades and troubleshooting via the network, or on an individual monitor share configuration settings between monitors back up the monitor settings. A password-protected Service Mode ensures that only trained staff can access service tests and tasks. The Configuration Mode is password-protected and allows trained users to customize the monitor configuration. Device Connections The monitor can be connected to: a Multi-Measurement Server and a Measurement Server Extension an Information Center (for example M3150B) 2 a PC 2. Network Interface 2 The network interface provides the system with networking capability via a wired or wireless network connection. 1.Not available in the US. 2.Not MP20 Junior 7
8 Further Optional Connection Interfaces 1 Any two of the following optional interfaces can be installed in the monitor. Parallel Printer Interface The Parallel Printer Output port can be used to connect any off-the-shelf printer that complies with the specifications. Flexible Nurse Call Relay The Flexible Nurse Call Relay board provides a means for alarms generated on the monitor to be signalled on an external device such as a nurse call system, a beeper or a light. It provides three general alarm relays and one power fail alarm. The external device is connected to the alarm relay and alarms are triggered by criteria defined by the user. It has active open and closed contacts and a user-definable delay time. MIB-ready/RS-232 Interface MIB, Medical Information Bus (IEEE P1073), is a standard for interfacing medical devices, allowing full integration of these devices. The monitor has a serial MIB/RS-232 interface board with two fullyisolated MIB ports. Both ports can be independently configured to be used for: input for connection to a touchscreen data export using a computer interface, to an automated anesthesia record keeper or a personal computer (not available in all geographies) Monitor Specifications See the individual Data Sheets for measurement server and measurement server extension specifications. Safety Specifications The monitor, together with the Multi-Measurement Server (M3001A), and all measurement server extensions, comply with the Medical Device Directive 93/42/EEC (CE 0366 ) and with IEC : A1: A2:1995; EN : A1: A2:1995; UL :2003; UL :1994; CAN/CSA C22.2#601.1-M90; JIS T ; IEC :2000; EN :2001; IEC :2001; EN :2001. All applied parts are Type CF unless otherwise specified. They are protected against damage from defibrillation and electrosurgery. The possibility of hazards arising from software errors was minimized in compliance with ISO 14971:2000, EN : A1:1999 and IEC : A1:1999. This ISM device complies with Canadian ICES Cet appareil ISM est conforme a la norme NMB-001 du Canada. Physical Specifications Physical Specifications Input Device Interface (2 PS/2 Interfaces) This interface provides two PS/2 ports to enable the monitor to be connected to off-the-shelf input devices. Remote Device Interface Product M8001A IntelliVue MP20/ M8001A IntelliVue MP20 Junior/M8002A IntelliVue MP30 (including M3001A and battery, without options) M3001A Multi-Measurement Server (MMS) Max Weight < 6 kg (13.2 lb) W x H x D < 345 x 275 x 230 mm (13.6 x 10.8 x 9 in) This interface is required to connect a Remote Alarm Device and one Remote SpeedPoint to the monitor. < 650g < 1.4lb 188 x 96.5 x 51.5 mm (7.4 x 3.8 x 2 in) x 96.5 x 38.5 mm (7.4 x 3.8 x 1.5 in) M3015A Measurement Server Extension - Microstream CO 2 < 550 g < 1.21 lb 1.Not MP20 Junior 8
9 Physical Specifications Product M3016A Measurement Server Extension - Mainstream CO 2 M3012A Hemodynamic Measurement Server Extension M8025A Remote Alarm Device M8026A Remote SpeedPoint Environmental Specifications < 450 g < 0.99 lb x 96.5 x 38.5mm (7.4 x 3.8 x 1.5 in) < 550 g 98 x 40 x 190 mm < 300 g < 0.7 lb < 400 g < 0.9 lb Environmental Specifications: Monitors Item Condition Range Temperature Range Humidity Range Altitude Range Battery storage 62 x 125 x 63 mm (2.4 x 5 x 2.5 in) 103 x 139 x 63 mm (4 x 5.5 x 2.5 in) Operating 0 to 40 deg. C (32 to 100 deg. F) Non-operating -20 to 60 o C (-4 to 140 (without o F) battery) Operating Non-operating Operating Non-operating Max Weight W x H x D 20% to 85% Relative Humidity (RH) (non condensing) 5% to 85% Relative Humidity (RH) 0 m to 3000 m (10000 ft) 0 m to m (40000 ft) -20 to 50 deg. C (-4 to 122 deg. F) Performance Specifications Monitor Performance Specifications Power Specifications SVGA Display 10.4 inch Sweep Speeds Power consumption < 100 W Line Voltage 100 to 240 V ~ Current 1.0 to 1.8 A Frequency 50/60 Hz Resolution 800 x 600 Refresh rate 60 Hz Useful screen x mm Pixel size x mm 6.25, 12.5, 25 and 50 mm/s with ±5% accuracy (guaranteed only for integrated displays) Indicators Alarms Off red LED Alarms red/yellow/cyan LED On/Standby green LED AC Power green LED Battery red-yellow-green LED Error red LED Sounds Audible feedback for user input. Prompt tone. Two different QRS tones, SpO 2 modulation tone. Four different alarm sounds Trends: 12, 16, 24 or sec, 1 minute, 5 minute resolution. Multiple choices of number of numerics, resolution and duration depending on application area. Review Alarms Window Real Time Clock Buffered Memory Information: all alarms / inops, main alarms on/off, alarms acknowledged and time of occurrence capacity 100 items Range: from: January 1, 1997, 00:00 to: December 31, 2080, 23:59 Accuracy: < 2 seconds per day (typically) Hold Time: infinite if powered by AC; otherwise at least 48 hours (typical: > 72 hours) Contents: Active settings, trends, snapshots, events, review alarms Hold Time: infinite if powered by AC; otherwise at least 48 hours (typical: > 72 hours) Restart time: After power interruption, an ECG wave will be shown on the display after 30 seconds maximum. 9
10 Battery Specifications One or two batteries can be used to operate the monitor. Special Philips high-power batteries M4605A 10.8 V 6000mAh Lithium Ion Battery PN (removable, with hot swap capability) Weight: 480g per battery Status LEDs indicate charge status of batteries Battery Operating Time: - With basic monitoring configuration (automatic brightness reduction, MMS in use, NBP every 15 minutes):5 hours (with two batteries) or 2.5 hours (with one battery) - With extended monitoring configuration (maximum brightness, MMS and CO 2 Measurement Server Extension in use, NBP every 15 minutes, recorder every 15 minutes): 4 hours (with two batteries) or 2 hours (with one battery Battery Charge Time: - when monitor is switched off: about 4 hours when monitor is switched on and fully functional: 5 to 12 hours depending on configuration. Interface Specifications Monitor Interface Specifications Network Standard IEEE Base-T Connector RJ45 (8 pin) Isolation 1.5 kv Parallel Standard IEEE 1284-I Printer Port Connector DB-25 Isolation 1.5 kv Dual PS/2 Inputs Dual MIB/ RS232 Output Voltage Output Current 5V ± 10 % 250mA (comb. max) to connected PS/2 devices Standard IEEE Connectors RJ45 (8 pin) Mode Software-controllable BCC (RxD/TxD cross over) or DCC (RxD/TxD straight through) Power 5V +/- 5%, 100mA (max.) Isolation 1.5kV ECG Output/Marker Input (1/4 stereo phone jack with tip, ring, sleeve) Monitor Interface Specifications General Connector 1/4 phone each with tip, ring, sleeve Isolation 500 V ECG Output (ring, tip) Marker Input Requirements (tip) Flexible Nurse Call Relay Signal Gain 320 to 3200 Full Scale 3.2V pp on Display Gain Error <20% Baseline <150mV Offset Bandwidth 1 to 80Hz Output Impedance Signal delay Signal Type Pulse Source Impedance Pulse Fall Time Pulse Duration Compatible Devices Printers ECG Output (ring): <2.2KΩ±20% ECG Output/Marker Input (tip) <2.5kΩ ±20% 30ms 0 to -12V, negative edge pulse <7kΩ <100µs >4ms Connector 20 pin MDR (Mini D- Ribbon), active open and closed contacts 3.5 mm phone jack, active closed contact only Contact <= 100 ma, <= 24 V DC Isolation 1.5 kv Delay < (Configured Latency sec) PCL5 capability required HP Laserjet 1200 (monochrome) HP Laserjet 2100 (monochrome) HP DeskJet 2500 C+ (color) 10
11 Ordering Information Ordering information for the M8001A/M8002A patient monitor is given here. See the individual Data Sheets for detailed ordering information for the measurement servers and measurement server extensions. For MP20 Junior order M8001A option M20 plus additional options as required from tables below. Basic Functionality Application Options MP20/ MP30 (M8001A/ M8002A) MP20 Junior (M8001A #M20) Order one Hxx option General/ICU Configuration H10 H10 Neonatal Configuration H20 H20 OR/Anesthesia Configuration a H30 -- Cardiac Configuration H40 -- Order for MP20/30 one Axx option 3 Realtime Wave Segments A Realtime Wave Segments A Realtime Wave Segments b A06 -- a. If EGM is required, H30 must be ordered. H30 not available with MP20 Junior. b. A06 not available in the USA. Measurement Options Measurements Measurement Servers Hardware Options Option Multi-Measurement Server M3001A, for Resp, ECG (inc. EASI), NBP, SpO2, and Pressure/Temperature. See the MMS Data Sheet for details. Add Press/Temp C06 Add Conventional 12 lead C12 ECG Add Press/Temp and Conventional 12 lead ECG Microstream CO2 Extension M3015A Add Press/Temp Mainstream CO2 Extension (with Press/Temp) Without CO 2 Hemodynamic Measurement Server Extension (with Pressure, Temperature, and Pressure/ Temperature) a a.not MP20 Junior Add Cardiac Output Add Cardiac Output and Continuous Cardiac Output M3016A M3012A C18 C06 A01 A02 C05 C10 Application Options M8001A M8002A Cardiac Applications MP20 MP20 Junior MP30 Basic Arrhythmia Incl. Incl. Included Full Arrhythmia C01 -- Included Neonatal Applications OxyCRG C08 -- C08 Neonatal Event Surveillance C04 -- C04 (includes OxyCRG) Clinical Applications Hardware Add-Ons Built-in recorder Battery operation (except MP20 Junior, has battery capability as standard) 1x High Power Lithium-Ion battery a 2x High Power Lithium-Ion batteries a Quick Release Mount Interface Options M8001A/ M8002A E05 E25 E24 E26 E22 a.one battery is standard with MP20 Junior, for a second battery order M4605A. Drug Calculator C05 -- C05 Advanced Hemodynamic Capability C30 -- C30 Interfaces (not available for MP20 Junior) M8001A/ M8002A Full Customization C20 Networking software (included in M8002A) C15 RS232 Interface (MIB-ready), 2 ports a J13 Parallel Printer Interface a J14 Wireless network adapter kit J20 2 PS/2 Interfaces a J22 11
12 Interfaces (not available for MP20 Junior) Remote SpeedPoint Interface ab Flexible Nurse Call Relay a Advanced interfacing capability: SVGA Video, Nurse Call Relay and Wireless Network Kit Networking interface card (MP20 only, already included in MP30) M8001A/ M8002A J23 J30 J40 J42 a. A maximum of 2 of these options can be selected. b. Required for Remote Alarm Device and for remote input devices (e.g. Remote SpeedPoint, keyboard, mouse). Documentation All documentation is available in.pdf format on documentation CD-ROM. Additionally, a printed copy of the Instructions for Use and Quick Guide ships with each monitor. Instructions for Use (printed) Quick Guide (printed) Installation and Service Guide Configuration Guide Documentation CD-ROM Cables M8022A Related Products Length Description a Product/Option Related Products Input Devices a Slimline keyboard with protective cover a.not MP20 Junior Mounting Information For mounting hardware, contact your local Philips sales representative. For GCX mounting hardware information, see Support Tool M3086A A02 Support Tool CD-ROM Model Number M8024A M8024A #A01 Mouse; wired M8024A #B01 Trackball; wired M8024A #C01 Trackball; wireless M8024A #C02 off table track mouse wired M8024A #C03 Remote Alarm Device a Connection cables: Remote SpeedPoint Device a Connection cables: Support Tool M8025A 1.5 m #HF2 3 m #HF3 10 m #HF6 15 m #HF7 25 m #HF9 M8026A 1.5 m #HF2 3 m #HF3 10 m #HF6 15 m #HF7 25 m #HF9 M3086A Analog Video 1.5 m Monitor to Display M8022A #VA2 3.0 m Monitor to Display M8022A #VA m Monitor to Display M8022A #VA m Monitor to Display M8022A #VA m Monitor to Display M8022A #VA9 Interface Cables Length Description b Product/.Option 1.5 m Monitor to Remote Device M8022A #HF2 3.0 m Monitor to Remote Device M8022A #HF m Monitor to Remote Device M8022A #HF m Monitor to Remote Device M8022A #HF m Monitor to Remote Device M8022A #HF9 MIB RS/232 Cables 1.5 m Serial cable M8022A #SR2 3.0 m Serial cable M8022A #SR m Serial cable M8022A #SR m Serial cable M8022A #SR m Serial cable M8022A #SR9 Nurse Call Relay Cable 3.0 m standard (backward M8022A #NC3 compatible) nurse paging relay cable c 10.0 m cable M8022A #NC6 ECG Out Cable 3.0 m standard ECG out cable d Wireless LAN Adapter Cable 0.3 m Y-Piece, DC supply plus LAN M8022A #SY3 M8022A #WLO a. Both ends terminated with HDSUB15 (VGA) connectors. b. Both ends terminated with straight MDR connectors. c. One end terminated with phone plug; other end w/o connector. d. Both ends terminated with 1/4 phone plug. 12
13 13
14
15
16 Philips Medical Systems is part of Royal Philips Electronics INTERESTED? Would you like to know more about our imaginative products? Please do not hesitate to contact us. We would be happy to provide specific information about our products and services, or put you on our mailing list for news about new product developments, upcoming events or for our clinical journal, MedicaMundi. We would be glad to hear from you. United States: Philips Medical Systems Cardiac and Monitoring Systems 3000 Minuteman Road Andover, MA (800) Canada: Philips Medical Systems Canada 281 Hillmount Road Markham, ON L6C 2S3 (800) On the web Contact us through our web site: Via Our for all remarks and requests is: By fax We can be reached at the following fax number: By postal service Please write to us at the following address: Philips Medical Systems Global Information Center I.B.R.S. / C.C.R.I. Numéro VC Eindhoven Pays-Bas / The Netherlands (no stamp required) Europe, Middle East and Africa: Philips Medizin Systeme Böblingen GmbH Cardiac and Monitoring Systems Hewlett-Packard Str Böblingen Germany Fax: (+49) Latin America Headquarters: Philips Medical Systems 1550 Sawgrass Corporate Parkway #300 Sunrise, Fl Tel: (954) Fax: (954) Asia Pacific Headquarters: Philips Medical Systems 30/F Hopewell Centre 17 Kennedy Road Wanchai Hong Kong Tel: (852) Fax: (852) Koninklijke Philips Electronics N.V. All Rights Reserved /862 * 2004 DEC M8001A and M8002A comply with the requirements of the Council Directive 93/42/EEC of 14 June 1993 (Medical Device Directive). 10
PAD. M3/M4 Compact Portable Patient Monitor. for the M3001A Multi-Measurement Server. PAD M3046A Software Revision E Data Sheet. Measurement Features
PAD M3046A Software Revision E Data Sheet M3/M4 Compact Portable Patient Monitor for the M3001A Multi-Measurement Server Measurement Features Patient demographics, measurement data and trends, acquired
IntelliVue MP40/MP50 Patient Monitor
IntelliVue MP40/MP50 Patient Monitor Philips M8003A, M8004A Technical Data Sheet The IntelliVue MP40 and MP50 portable patient monitors are compact in size, ergonomic, and modular in design. They share
High-intensity performance. IntelliVue MP90 patient monitor
High-intensity performance IntelliVue MP90 patient monitor See a higher level The IntelliVue family of networked patient monitors gives care teams throughout the hospital more of the information they need
Networked versatility. IntelliVue MP60 and MP70 patient monitors
Networked versatility IntelliVue MP60 and MP70 patient monitors Critical performance The IntelliVue family of networked patient monitors gives care teams throughout the hospital more of the information
IntelliVue MX800 Patient Monitor
IntelliVue MX800 Patient Monitor Philips 865240 Technical Data Sheet The Philips IntelliVue MX800 patient monitor offers a flexible and modular monitoring solution, designed to suit a broad spectrum of
Datex-Ohmeda Critical Care Monitor
GE Healthcare Datex-Ohmeda Critical Care Monitor Comprehensive monitoring for the challenging Critical Care environment Critical Care monitor offers a flexible range of module frame options, displays and
Connect care for early intervention
IntelliVue Information Center ix Central monitoring station Connect care for early intervention See more. Know more. Do more. Connecting your teams to each other and to the information they need supports
Philips PageWriter Touch ECG System
Philips PageWriter Touch ECG System Features: Easy, Fast, 12-Lead ECGs for Large or Small Hospitals Designed for high volume High resolution touch screen Preview reports before printing Wireless communication
SureSigns VM Series Patient Monitors
SureSigns VM Series Patient Monitors INSTRUCTIONS FOR USE Release A.02 English Notice Proprietary Information This document contains proprietary information, which is protected by copyright. Copyright
INSTRUCTIONS FOR USE. IntelliVue Patient Monitor. MP20/30, MP40/50, MP60/70/80/90 Release G.0 with Software Revision G.0x.xx. Patient Monitoring
INSTRUCTIONS FOR USE IntelliVue Patient Monitor MP20/30, MP40/50, MP60/70/80/90 Release G.0 with Software Revision G.0x.xx Patient Monitoring Part Number M8000-9001K Printed in Germany 09/08 4512 610 29531
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.
17" (43 cm) LCD Monitor Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission. Long Distance Transmission Easily
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
D-19673-2015. A cost effective monitor that meets your clinical needs VISTA 120
D-19673-2015 A cost effective monitor that meets your clinical needs VISTA 120 02 VISTA 120 03 Part of a complete departmental solution A comprehensive monitor at exceptional value D-3533-2011 Hospitals
TrueAlarm Fire Alarm Systems
TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control
INNOC. Innocare-T. Innomed. Innomed s intensive and anesthesiological monitor system can be used both as a transport or bed-side care unit
Innocare-T Portable patient monitoring system INNOC Innomed s intensive and anesthesiological monitor system can be used both as a transport or bed-side care unit The most modern technology Large color
IntelliVue MP5/MP5T TRAINING GUIDE. IntelliVue Patient Monitor. MP5/MP5T Release G.0 with Software Revision G.0x.xx. Patient Monitoring
IntelliVue MP5/MP5T TRAINING GUIDE IntelliVue Patient Monitor MP5/MP5T Release G.0 with Software Revision G.0x.xx Patient Monitoring Philips Medizin Systeme Boeblingen GmbH Hewlett-Packard-Str. 2 71034
HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB
Product datasheet Characteristics HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB Main Range of product Product or component type Display colour Display size Supply Magelis
SCD Server. SCD Server Pro
SCD Server SCD Server Pro SCD Server & SCD Server Pro 9850-000387-01 - Page 1 of 8 SCD Server and SCD Server Pro The SCD Server is a 2U high DMX generator, running the ZerOS Operating System and emulating
OMNI TOUCH SCREEN PATIENT MONITOR
OMNI TOUCH SCREEN PATIENT MONITOR OMNI n Intuitive Designed for a fast paced work environment, the Infinium Omni series patient monitors offers an extremely simple and adaptable user interface. The Omni
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
Bedside Monitor BSM-9101K
Bedside Monitor BSM-9101K For the Patients For the Caregivers Life Scope J is based on our more than half a century of experience manufacturing medical equipment More flexible, more user-friendly, higher
Series. Laser air Leddura Lexinus Mensa. 70 inch. Smart innovation! When function matters.
Leddura Lexinus Mensa Series When function matters. High quality displays suitable for all applications. Stay connected to your audience via the built-in wireless access point for a productive and collaborative
MANUAL PC1000R [email protected]
MANUAL PC1000R [email protected] Features The APart PC1000R is a professional multisource CD/USB/SD card music player, equipped with balanced and unbalanced analog outputs, coaxial and optical digital
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.
ENDURA - WS5050 PC WORKSTATION TECHNICAL SPECIFICATIONS SECURITY SYSTEM DIVISION 28 ELECTRONIC SAFETY AND SECURITY LEVEL 1 28 20 00 ELECTRONIC SURVEILLANCE LEVEL 2 28 23 00 VIDEO SURVEILLANCE LEVEL 3 28
Vista 120 Central Monitoring System
Vista 120 Central Monitoring System Today, hospitals seek to improve their quality of care and work as efficiently as possible. The easy-to-use Vista 120 Central Monitoring System lets you centrally monitor
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
Capnostream 20p Bedside Capnography Monitor. The only integrated, complete picture of oxygenation and ventilation 1
Capnostream 20p Bedside Capnography Monitor The only integrated, complete picture of oxygenation and ventilation 1 Smart Capnography and Pulse Oximetry Technology Smart Capnography is a suite of algorithms
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise
DC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
S/5 Anesthesia Monitor. The clinician s choice
S/5 Anesthesia Monitor The clinician s choice S/5 Anesthesia Monitor S/5 Anesthesia Monitor Designed by clinicians for clinicians The S/5 Anesthesia Monitor gives you the time and freedom to monitor your
Philips CMS Patient Monitoring System Configuration Manual Anesthesia/Neonatal/Standard
Philips CMS Patient Monitoring System Configuration Manual Anesthesia/Neonatal/Standard PAD Part Number M1046-9322L Printed March 2003 Notice This document contains proprietary information which is protected
QuickSpecs. HP IP Console Switch with Virtual Media Overview
Overview HP's IP Console Switch with Virtual Media is a key component in managing the heterogeneous data center and along with the IP Viewer software allows remote access to multiple servers running various
510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure
CAS MEDICAL SYSTEMS, INC. 510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure using the 2301Multi-Function Tester 44 East Industrial Road Branford, CT 06405 USA [email protected]
WF720 Wireless Home Phone User Manual
WF720 Wireless Home Phone User Manual Content Getting to Know Your Device... 3 Appearance...3 LED Indicator...4 Device Installation... 5 Before You Begin...5 Installing the SIM Card and the Battery...5
EV-1000 Series DVR. Quick Operation Guide. Version 1.0.0
EV-1000 Series DVR Quick Operation Guide Version 1.0.0 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to
Expand your view. IntelliVue MX600, MX700, and MX800 bedside patient monitors
Expand your view IntelliVue MX600, MX700, and MX800 bedside patient monitors Trusted by more, for more Philips IntelliVue patient monitors are already the world s best selling, providing the accurate,
Product Information Sheet UH36 Hi Pot Tester
Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: [email protected] Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de
R Series Quick Reference Guide
R Series Quick Reference Guide 2010 ZOLL Medical Corporation. All rights reserved. CPR Index, OneStep, R Series, Real CPR Help, See-Thru CPR, statpadz, and ZOLL are trademarks or registered trademarks
Technical Note Series
Technical Note Series SKIN CONDUCTANCE SENSOR (SA9309M) S TN0 0 0 8-0 0 S k i n C o n d u c t a n c e S e n s o r Page 2 IMPORTANT OPERATION INFORMATION WARNING Type BF Equipment Internally powered equipment
AXIS 262+ Network Video Recorder
31433/EN/R4/0803 Complete Network Video Recording Solution Complete Network Video Recording Solution Picture this: A simple and reliable, plug-and-play video surveillance system for hotels, shops, banks,
Dash 18X / Dash 18 Data Acquisition Recorder
75 Dash 18X / Dash 18 Data Acquisition Recorder QUICK START GUIDE Supports Recorder System Software Version 3.1 1. INTRODUCTION 2. GETTING STARTED 3. HARDWARE OVERVIEW 4. MENUS & BUTTONS 5. USING THE DASH
EPSON Perfection 1650/1650 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. device Effective pixels
Scanner Parts Start and indicator light Photo Print USB port The has a transparency unit built into the scanner lid and holder for 35 mm film and slides: EPSON Perfection 1650 owners can purchase an optional
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
3200L 32" Interactive Digital Signage Touch Display
3200L 32" Interactive Digital Signage Touch Display The 3200L Interactive Digital Signage (IDS) display combines precision Elo touch screen technology with a professional-grade, large format LCD panel.
GE Healthcare. B40 Patient Monitor Connecting intelligence and care.
GE Healthcare B40 Patient Monitor Connecting intelligence and care. The right monitor for your clinical demands The B40 Patient Monitor from GE Healthcare provides versatile clinical capabilities to help
T 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.
A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance. Bulletin -01E http://www.yokogawa.com/tm/... Visit our website to sign for e-mail updates Compact,
DSB-100 Portable Premium Bluetooth Speaker Owner s Manual
. DSB-100 Portable Premium Bluetooth Speaker Owner s Manual You can print more than one page of a PDF onto a single sheet of paper. 1 Index Preparation Unpacking 3 Overview 4 Sound Quality 4 Design 4 Operation
Dash 8Xe / Dash 8X Data Acquisition Recorder
75 Dash 8Xe / Dash 8X Data Acquisition Recorder QUICK START GUIDE Supports Recorder System Software Version 2.0 1. INTRODUCTION 2. GETTING STARTED 3. HARDWARE OVERVIEW 4. MENUS & BUTTONS 5. USING THE DASH
COLOR TFT LCD MONITOR. User Manual
COLOR TFT LCD MONITOR User Manual GENERAL INFORMATION Thank you for choosing our TFT LCD(liquid crystal display) monitor. This product employs integrate circuits, low power consumption, and no radiation
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
rigel 288 Electrical Medical Safety Analyser Key Features Applications
rigel 288 Electrical Medical Safety Analyser Key Features Versatile Test in Accordance with the leakage requirements of IEC/EN 60601-1, AAMI and NFPA, IEC 62353 (VDE 0751-1) using separate IEC 60601 and
GV-Keyboard. User's Manual V2.0
GV-Keyboard User's Manual V2.0 Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2007 GeoVision, Inc. All rights reserved.
Laerdal Patient Monitor Help Page 1 June 14, 2012, Rev E
Laerdal Patient Monitor Help Page 1 Using the Laerdal Patient Monitor The Laerdal Patient Monitor software is used to simulate a typical Patient Monitor found in hospitals and ambulances. It is made available
HP Advanced Wireless Docking Station. User Guide
HP Advanced Wireless Docking Station User Guide Copyright 2014, 2015 Hewlett-Packard Development Company, L.P. Intel is a trademark of Intel Corporation in the U.S. and other countries. Windows and Windows
2100 POS System. 2100 User Guide
2100 POS System 2100 User Guide Thank you for selecting UTC RETAIL s innovative Model 2100 Point of Sale solution! This guide is designed to acquaint you with the features and functionality of the 2100
Sympodium Interactive Pen Display
Physical Specifications Sympodium Interactive Pen Display Specifications Model DT770 Size Display Area Weight Shipping Size Shipping Weight (Carton and Contents) 19" W 18" H 3 5/8" D (48.3 cm 45.7 cm 9.2
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
1 Technical Description Lokal-200PC
1 Technical Description Lokal-200PC 1.1 Overview laptop with in-built accummulator USB connection correlator box internal power supply laptop (if the device has been supplied by F.A.S.T.) BNC aerial connection
Macintosh Portable. Overview
Overview The Apple Macintosh able personal computer offers complete Macintosh functionality in a portable design. It runs virtually all current versions of Macintosh software and provides full compatibility
FREJA 300 Relay Testing System
Relay Testing System A Megger Group Company FREJA 300 Relay testing system The FREJA 300 relay testing system is a computer-aided relay testing and simulation system. The weight of FREJA 300 is only 15
MS9500 SERIES VOYAGER PRODUCT GUIDE. Single Line, Hand-Held, 1D, High-Density 1D, PDF-417 2D and Wireless Laser Bar Code Scanners
MS9500 SERIES VOYAGER PRODUCT GUIDE Single Line, Hand-Held, 1D, High-Density 1D, PDF-417 2D and Wireless Laser Bar Code Scanners Contents About Voyager Scanners Voyager Selection Chart MS9520 Voyager MS9540
SMART Board 685ix interactive whiteboard system Model 685ix
Specifications SMART Board 685ix interactive whiteboard system Model 685ix Physical specifications SMART Board 685ix interactive whiteboard 77 1/2" W 49 1/2" H 5 1/8" D Size (196.9 cm 125.7 cm 13 cm) Active
Disturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
Lenovo ThinkVision L197 Widescreen LCD Monitor View your images on a wide screen
Lenovo Europe Announcement ZG08-0333, dated April 15, 2008 Lenovo ThinkVision L197 Widescreen LCD Monitor View your images on a wide screen Description...2 Product positioning... 5 At a glance The Lenovo
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
Product Information S N O. Portable VIP protection CCTV & Alarm System 2
Product Information S N O Portable VIP protection CCTV & Alarm System 2 G O V E R N M E N T A L S E C U R I T Y S O L U T I VIP KIT Rapid Deployment VIP Protection Kit The VIP KIT has been designed to
IntelliVue MP20/30. Service Guide. IntelliVue Patient Monitor. MP20/MP20Junior/MP30. Patient Monitoring
IntelliVue MP20/30 Service Guide IntelliVue Patient Monitor MP20/MP20Junior/MP30 Patient Monitoring Part Number M8001-9301F 453564112561 *M8001-9301F* Contents 1 Introduction 9 Who Should Use This Guide
X Series Extensive Capabilities
X Series Extensive Capabilities for Patient Transport Transporting Patients throughout the Hospital Requires the Right Equipment Full Featured yet Compact When transporting critically ill patients, you
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
How To Sell A Talan
The TALAN represents state-of-the-art capability to rapidly and reliably detect and locate illicit tampering and security vulnerabilities on both digital and analog telephone systems. Marketing Characteristics
LCD Drawer User Manual
LCD Drawer User Manual - 1 - This manual, covering various aspects of the equipment such as installation, setup and installation, will help you make full use of this LCD KVM Drawer. Please read this manual
Senses SV series industrial monitor user manual
Industrial Monitors Senses SV series Senses SV19 / SV17 User manual (Issue A) Part No: 85090084 Page 1 of 25 Copyright Copyright 2008 Amplicon Liveline Ltd. All rights reserved. This publication, including
How To Use An Easymp Network Projector On A Computer Or Network Projection On A Network Or Network On A Pc Or Mac Or Ipnet On A Laptop Or Ipro Or Ipo On A Powerbook On A Microsoft Computer On A Mini
EasyMP Network Projection Operation Guide Contents 2 Before Use Functions of EasyMP Network Projection....................... 5 Sharing the Projector....................................................
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
GE Healthcare. Avance Carestation. Innovating with you, shaping exceptional care
GE Healthcare Avance Carestation Innovating with you, shaping exceptional care Clinician inspired perioperative solutions GE s Avance Carestation was developed using an approach to perioperative solutions
A-307. Mobile Data Terminal. Android OS Platform Datasheet
A-307 Mobile Data Terminal Android OS Platform Datasheet Revision 1.1 July, 2013 Introduction A-307 Platform Overview Introduction A-307 Platform Overview The A-307 provides Original Equipment Manufacturers
Specifications for the Gateway M1300 Tablet PC
Specifications for the Gateway M1300 Tablet PC Specifications are subject to change without notice or obligation. Processor and Core Logic Processor options Chipset Processor packaging Level 2 cache Core
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
You ll love the Vue. Philips IntelliVue Information Center ix
You ll love the Vue Philips IntelliVue Information Center ix IT Director It has to it into our IT infrastructure and integrate easily with our EMR and HIS. Clinical Engineering Make it easy to support.
OC821 Iris Outdoor Camera Set-Up Guide. RC8221 Iris. Camera Set-Up Guide
Outdoor Camera Set-Up Guide RC8221 Iris Camera Set-Up Guide 2 2 A B Package Contents Basic A. Outdoor Setup Camera This B. chapter Power provides Adapter details on how to setup and mount the camera. C.
EPSON Perfection 2450 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. US letter or A4 size (8.5 11.7 inches [216 297 mm])
Scanner Parts Start button power button (TPU) under lid IEEE 1394 port Scanner Specifications Basic Specifications Scanner type Photoelectric device Effective pixels USB port indicator light document cover
Raptor RXi Ultra-fast scanning Countersurveillance Receiver
data sheet RAPTOR RXi DATA SHEET A MATTER A MATTER OF OF NATIONAL SECURITY Raptor RXi Ultra-fast scanning Countersurveillance Receiver Features + Scans 26GHz in less than 4 seconds at 3kHz resolution (approx.
Back-UPS Pro 1300/1500 Installation and Operation
Back-UPS Pro 1300/1500 Installation and Operation Inventory Safety Do not install the Back-UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Connect the battery bu059a bu058a
Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
FPV MONITOR. User Manual
FPV MONITOR User Manual Important Safety Instructions: Please read User Guide before using this product. Please keep User Guide for future reference. Please read the cautions to prevent possible danger
HP Server Console Switch with Virtual Media Overview
Overview HP's Server Console Switch with Virtual Media is a key component in managing the data center. Connections for two local consoles (a console represents one keyboard, monitor and mouse) allow access
SMART Board interactive whiteboard system
PLEASE THINK BEFORE YOU PRINT Specifications SMART Board interactive whiteboard system Model 680i3 Physical specifications SMART Board 680 interactive whiteboard Size 65 1/4" W 49 1/2" H 5 1/8" D (165.7
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
TORKEL 820 Battery Load Unit
TORKEL 820 Lightweight Expandable system Rugged and reliable for field use Test without disconnecting the battery from the equipment it serves Description During a power outage, crucial telecommunication
Wireless Link. Introduction. Setup, Configuration and Connection ENGLISH
ENGLISH Introduction This document is an addendum to the HeartStart MRx Instructions for Use. It explains how to use the features of the HeartStart MRx s Wireless Link Option. The Wireless Link Option
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
GeoMax GNSS Zenith10 & Zenith20 Series
GeoMax GNSS Zenith10 & Zenith20 Series GeoMax About Us At GeoMax we provide a comprehensive portfolio of integrated solutions by developing, manufacturing and distributing quality construction and surveying
A-317. Mobile Data Terminal. Android Platform Datasheet
A-317 Mobile Data Terminal Android Platform Datasheet Revision 1.4 October, 2014 Disclaimer: Micronet reserves the right to change product specifications without prior notice. Introduction A-317 Platform
IntelliVue MP5/MP5T. Service Guide. IntelliVue Patient Monitor MP5/MP5T. Patient Monitoring
IntelliVue MP5/MP5T Service Guide IntelliVue Patient Monitor MP5/MP5T Patient Monitoring Part Number M8105-9301C 453564112551 *M8105-9301C* Table of Contents 1 Introduction 9 Who Should Use This Guide