Sound Control For Commercial And Residential Buildings
|
|
|
- Irma Poole
- 9 years ago
- Views:
Transcription
1 Sound Control For Commercial And Residential Buildings
2 Table Of Contents Methods Of Sound Control 1 Sound Transmission Class (STC) And Sound Control 1 The Effects Of Insulation Thickness And Density On STC Ratings 2 Controlling Impact Noise 2 Improving Office To Office Sound Reduction 2 Controlling Exterior Sounds 3 Examples Of Ways To Construct Walls And Floors/Ceilings To Achieve Desired STCs 4 Sound Isolation Design Criteria 5 Guide Specification for Fiber Glass Acoustical Insulation 7 Typical Wall Assemblies Single Wood Stud Walls 8 Staggered Wood Stud Walls 9 Double Wood Stud Walls 10 Metal Stud Walls 11 Exterior Walls 12 Typical Floor/Ceiling Assemblies 14 Recommended Construction Methods for Controlling Sound 15 Glossary 20 Bibliography 21 How Noise Effects Us Unwanted sound or noise that travels from room to room, from home to home, or office to office, may have a direct impact on people s notions of privacy, as well as their work efficiency. The noise produced by appliances, piping, heating and airconditioning systems, phones, radios,tvs and talking are among the major reasons people are dissatisfied with the privacy found in homes or office buildings.additionally, external noises such as traffic, sirens and extreme weather conditions are equally disturbing. Designing structures to control noise effectively can make homes and offices much more pleasant places in which to live or work.
3 This Sound Control Guide recommends ways to construct walls and other assemblies using fiber glass insulation to help provide quality noise control. The North American Insulation Manufacturers Association (NAIMA) developed these recommendations based on the results of numerous acoustical tests using American Society for Testing and Materials (ASTM) methods. However, the recommendations are presented here solely as a guide. NAIMA cannot guarantee, does not represent or warrant, and assumes no responsibility for building design or construction results based on information provided in this booklet because many other factors including overall design and workmanship are outside its control. Decibels And Sound Transmission Class The decibel (db) is used to express sound intensity or loudness.the more intense a sound, the higher the db level.the sound transmission class (STC) is a numerical rating of the ability of a wall, floor/ceiling assembly or any other building element such as a door or window to minimize sound transmission. The higher the STC rating the more the sound is blocked or reduced by the building element (See Table 1). For party walls or walls separating dwelling units, an STC of 50 is considered barely adequate for providing privacy. STCs above 55 are required to provide acceptable privacy. Methods Of Sound Control Noise is unwanted sound that is transmitted by vibration through air, walls, floors or ceilings. In a home or office, there are three ways to control sound transmission: Increase the mass of partitions Break the path of vibration Cavity absorption. Increasing the mass of walls and other structures can present a problem in lightweight construction because the increased weight may not be structurally practical or aesthetically pleasing, not to mention more expensive. Breaking the vibration path commonly called discontinuous construction offers a practical method of reducing sound transmission by as much as 6 to 10 db. Cavity absorption, which uses fiber glass insulation to fill the space in walls and floors/ceilings, can further improve performance of discontinuous constructions by 5 to 15 db. Sound Transmission Class (STC) And Sound Control STC ratings are a measure of the effectiveness of a given partition construction in reducing airborne sound transmission. Because of the frequency range covered ( Hz),STC ratings are best used to evaluate speech privacy for partitions and floors/ceilings separating adjacent offices, rooms in one and two family dwellings, hospital patient rooms, classrooms, dormitories, apartments, courtrooms, small conference rooms, etc.a more extensive TABLE 1 STC Ratings Sound Noise Transmission Speech Control Class (STC) Audibility* Rating 15 to 25 Normal speech easily Poor understood. 25 to 35 Loud speech easily Marginal understood. Normal speech 50% understood. 35 to 45 Loud speech 50% Good understood. Normal speech faintly heard, but not understood. 45 to 55 Loud speech faintly heard, Very Good but not understood. Normal speech usually inaudible. 55 and up Loud speech usually inaudible Excellent *Given a typical background noise level of 30 db on the listening side acoustical analysis should be obtained from an acoustical engineer when isolating sound from locations such as music practice rooms, recording studios, large conference rooms and mechanical equipment rooms. Ratings Based On Lab Tests STC ratings are based on laboratory tests conducted under ideal construction conditions. Partition manufacturers acknowledge that the field STC of a partition can be up to points lower than laboratory values depending on the quality of detailing and workmanship. Therefore, the importance of communication between the design team and the construction team cannot be overemphasized. 1
4 Fiber Glass Insulation Reduces Sound Transmission Fiber glass insulation in a partition or floor/ceiling assembly significantly reduces sound transmission. It also reduces sound transmission in roof/ceiling assemblies. It is economical, lightweight and easy to install. Some fiber glass insulation manufacturers sell acoustical or sound control batts for use in partitions. These batts are designed for easier installation in metal and wood stud partitions.they are essentially the same as their corresponding thermal batts, except that they may differ slightly in size and density.a partition with either fiber glass sound control or thermal batts having similar properties would achieve the same STC rating. Factors That Degrade Performance The presence of flanking paths, interconnecting ductwork, non-airtight edge joints, inadequate door and window constructions, untreated pipe and conduit penetrations, etc., all degrade the expected performance of a sound rated assembly.when proper attention to construction details are followed, field STC values can be equal to or even greater than laboratory values. The Effects Of Insulation Thickness And Density On STC Ratings Insulation thickness has a more significant effect on STC ratings than does density.for a typical steel stud wall construction, the first inch of fiber glass insulation can increase the STC value 6 or more points. Each additional inch of fiber glass insulation increases the STC value from one to two points. Conversely, density variations have minimal effect on the STC rating.(see Table 2.) Controlling Impact Noise Walls are rated only in terms of their STC value. Floor/ceiling assemblies because they must also control sounds caused by impacts (such as walking or moving furniture) are rated in terms of their STC and their impact insulation class, or IIC. A person walking on a floor creates impact noise that is readily transmitted to the room below.while carpets and pads can cushion impacts and reduce the generation of impact noise, fiber glass insulation can reduce impact and airborne noise transmitted through the floor/ceiling assembly.as with STCs, the higher the IIC value of a floor/ceiling, the better its ability to control impact sound transmission.an acceptable IIC rating is typically 50 or above. Differences Between Lab Tests Not Unusual Partitions with STC ratings within 1-2 points (1-2 db) of the listed criteria would still be acceptable given the anticipated tolerances in repeat tests. In fact, differences between testing labs of 2-5 db on identical test configurations are not unusual. (Subjectively, the human ear would consider a 1-2 db change as nondiscernible at best, which is insignificant.) STC Requirements Are From AIA The STC requirements in Table 3 (pages 5-6) are from the American Institute of Architects (AIA) and assume acceptable background noise levels on both sides of the construction assembly. Normal background noise on the listening side of a partition has the effect of masking transmitted sound that might otherwise be objectionable. In fact, sound transmitted through a partition will be inaudible if its sound level is below the level of the background noise. Improving Office To Office Sound Reduction In offices where the separating partition stops at the ceiling, sound can flank around the partition by traveling through the ceiling.this flanking sound travels up through the ceiling in one office, across the top of the partition and then down through the ceiling in the adjacent office. In many offices this flanking path is significant and degrades the sound isolation between offices.this is particularly true if the STC of the separating partition is greater than 45. TABLE 2 STC Values of Equal Thicknesses of Fiber Glass Insulation 3 5 8" steel studs; single layer 1 2" gypsum board each side Material Thickness Density STC Fiber Glass 2" 0.75 pcf 46 Fiber Glass 2" 1.30 pcf 46 Fiber Glass 2" 3.00 pcf 46 2
5 Fiber Glass vs. Cellulose Insulation Manufacturers of cellulose insulation claim that their insulation, when used in a partition, gives higher STC values than fiber glass insulation.this is not true. Numerous sound transmission loss tests conducted at independent laboratories have shown that there is no significant difference in STC ratings using either fiber glass or cellulose insulation.the STC ratings of walls using cellulose or fiber glass insulation are within 1 or 2 points of each other. Metal Framing vs. Wood Framing Light gage metal framing members are inherently flexible thus allowing the full potential of added cavity insulation to be realized. Single row wood stud framing, on the other hand, provides a high degree of mechanical coupling which can provide a short-circuit for sound transmission. In order to realize the full benefit of cavity insulation in wood framed construction, it is recommended that the gypsum board be attached to either side of the wood framing members using resilient channels. Staggered or double rows of wood studs can also be used to achieve the same benefit.tests have also shown that there is no significant acoustical difference between 2x4 and 2x6 inch wood studs. Preventing Ceiling Flanking Sound Transmission Ceiling flanking sound can be prevented by building partitions from the floor to the roof or floor deck above. However, many times this is not possible because of obstructions such as pipes, conduit and HVAC ducts in the ceiling plenum. In some HVAC designs the ceiling plenum is also used as an air return and partitions can not block the plenum. When this is the case there are two methods to reduce ceiling flanking sound. the type of grid system.the CAC is the single number rating used to express the sound reduction or attenuation between two rooms sharing a common ceiling and/or plenum (See ASTM standard E 1414).These CAC improvements can be achieved by using unfaced to 4 inch thick batts (R-11 batts).the batts only have to be placed on the back of the ceiling panels on both of sides of the partition a distance of 4 feet back from the partition. It is not necessary to back load the entire ceiling in both offices. Care must be taken not to cover light fixtures with the insulation.the insulation may cause the fixtures to overheat. Install A Fuzzwall The second method to reduce ceiling flanking sound transmission is to install a fiber glass wall above the separating partition. Such a wall or plenum barrier has been called a fuzzwall. (See figure below.) Fuzzwall Can Improve CAC Tests conducted by the National Research Council of Canada have shown that a fuzzwall can improve the effective CAC of a ceiling by 10 to 15 points depending on the type of ceiling panel in the ceiling, the type of ceiling grid system and the thickness of the fuzzwall. For air return plenums, openings can be provided in the fuzzwall for air flow.these openings would decrease the STC by approximately 5 points. Controlling Exterior Sounds Many residences and commercial buildings are adversely impacted by external sounds or noise. Therefore, it is critical to control both interior and exterior noise.typical exterior noise sources are automobile and truck traffic, trains, aircraft and our Basic fuzzwall configuration Backload Ceiling Panels With Low Density Fiber Glass Insulation The first method is to back load the ceiling panels with low density fiber glass insulation.the ceiling attenuation class (CAC) can be improved by 6 to 15 points depending on the type of ceiling panel and Ceiling/floor slab Stack of batts Suspended ceiling 3
6 neighbors.the best way to reduce the impact of exterior noise is not to build near these noise sources.when this is not possible then special measures must be taken to reduce their impacts.the shell of a residence or building must be designed to keep out noise. Residential Construction In residences, exterior walls should be constructed with resilient furring channels and fiber glass insulation in the stud cavity. If a residence is impacted by overhead aircraft then resilient channels should be used in roof/ceiling assemblies as well as using at least 9 inches of blown-in fiber glass insulation in the attic.the insulation should cover the top of the joists by at least 1 inch. There should be a minimum number of windows and doors on the side of home facing the exterior noise source.when windows are necessary on this side, they should be sound rated with an STC of at least 40.The same is true for doors facing a noise source. Recent retrofit programs done on residences near airports to reduce interior noise levels due to aircraft have shown that it is very critical to seal all air (sound) leaks in the building envelope. All fresh air intakes and exhausts must have silencers or mufflers. Most of the residences also had additional insulation installed in the attics to further reduce overhead aircraft noise. Commercial Construction In commercial buildings built near a highway or train tracks, the exterior building walls should have at least an STC of 50.Windows and doors should have at least an STC of 40 or 45 depending on the amount of window or door area.the higher the window or door area the higher the STC value. Roof/ceiling systems should also have a minimum STC of 50 if aircraft fly over the building. Higher STC values may be required if aircraft fly close to the building. In this case, an acoustical engineer should be consulted. Guide Specification For Fiber Glass Acoustical Insulation On page 7 is a guide specification that can be used by an architect to specify the acoustical insulation to be used in a wall or floor/ceiling assembly to achieve a desired STC rating.this same specification can be used to specify the acoustical insulation to be used to backload a ceiling system to achieve a desired ceiling STC rating. Examples Of Ways To Construct Walls And Floors/Ceilings To Achieve Desired STCs Beginning on page 8 are examples of the most common and typical wall and floor/ceiling assemblies that demonstrate how to improve sound control performance by using fiber glass batts and blankets. Most of the examples shown represent commonly used methods of construction; some variations of these constructions are also illustrated. STC Ratings The STC rating indicated for each assembly, in many instances, represents the median of a range of STC values.these median values may or may not be actual test results, but will provide an accurate estimate as to how the STC rating would be increased or decreased with progressive changes in construction. It s possible that an individual insulation manufacturer s results might differ slightly from the median values; however, any such differences would be insignificant. More detailed sound control information can be obtained by contacting an insulation manufacturer. Fire Ratings The fire ratings given are based on available test information from NAIMA members and independent testing laboratories.the test method used is ASTM E119.An NR indicates that the particular assembly illustrated is not rated. 4
7 Table 3 Sound Isolation Design Criteria Type of Occupancy Room(s) Considered (Source) Office Adjacent Area(s) (Receiver) Adjacent offices General office areas Corridor or lobby Washrooms and toilet areas Exterior of building Kitchen and dining areas Manufacturing areas and mechanical equipment rooms Sound Isolation Requirement (Min.) STC 52 STC 52 STC 52 STC 52 STC * STC 52 STC 52+ Executive areas, doctors suites confidential privacy requirements Normal office areas normal privacy requirements Office Adjacent offices General office areas Corridor or lobby Washrooms and toilet areas Exterior of building Kitchen and dining areas Manufacturing areas and mechanical equipment rooms STC 45 STC 45 STC 45 STC 47 STC * STC 47 STC 52+ Any normal occupancy, using conference rooms for group meetings or discussions Conference rooms Other conference rooms Adjacent offices General office areas Corridor or lobby Washrooms and toilet areas Exterior of building Kitchen and dining areas Manufacturing areas and mechanical equipment rooms STC 45 STC 45 STC 45 STC 45 STC 47 STC * STC 47 STC 52+ Normal business offices, drafting areas, banking floors, etc. Large general office areas Corridors or lobby Exterior of building Data processing areas Manufacturing areas and mechanical equipment areas Kitchen and dining areas STC 37 STC * STC 42 STC 47+ STC 42 Office in manufacturing, laboratory or test areas requiring normal privacy Shop and laboratory offices Adjacent offices Manufacturing, laboratory, or test areas Washrooms and toilet areas Corridor or lobby Exterior of building STC 42 STC 42+ STC 42 STC 37 STC * Motels and urban hotels (similar to apartments) Bedrooms Adjacent bedrooms, separate occupancy Bathrooms, separate occupancy Living rooms, separate occupancy Dining areas Corridor, lobby, or public spaces Mechanical equipment rooms Exterior of building STC 48+ STC 52+ STC 50+ STC 50+ STC 48+ STC 52+ STC * Apartments, multiple dwelling building Bedrooms Adjacent bedrooms, separate occupancy Bathrooms, separate occupancy Bathrooms, same occupancy Living rooms, separate occupancy Living rooms, same occupancy Kitchen areas, separate occupancy Kitchen areas, same occupancy Mechanical equipment rooms Corridors, lobby, public spaces Exterior of building STC 48-55* STC 52-58* STC 45-52* STC 50-57* STC 42-50* STC 52-58* STC 45-52* STC 58-65* STC 48-55* STC From The American Institute of Architects; Architectural Graphic Standards, Seventh Edition, pp 68 & 69. * Depends on the nature of the exterior background noise its level, spectrum shape, and constancy as well as on the client s budget and on thermal considerations. Use qualified acoustical consultants for analysis of high noise outdoor environments such as airport areas, highways (with heavy truck traffic especially), and industrial facilities. Use acoustical consultants for mechanical equipment rooms housing other than air handling equipment chillers, pumps, compressors, etc. and for heavy manufacturing areas employing equipment generating noise levels at or above OSHA allowable levels or generating high vibration levels. 5
8 Table 3 Sound Isolation Design Criteria (continued) Type of Occupancy Apartments, multiple dwelling building Private, single family residences Room(s) Considered (Source) Living rooms Bedrooms (living rooms similar) Adjacent Area(s) (Receiver) Adjacent living rooms, separate occupancy Bathrooms, separate occupancy Bathrooms, same occupancy Kitchen areas, separate occupancy Mechanical equipment rooms Exterior of building Adjacent bedrooms Living rooms Bathrooms, not directly connected with bedroom Kitchen areas Exterior of building School buildings Classrooms Adjacent classrooms speech use only Adjacent classrooms speech and audiovisual use Laboratories Corridor or public areas Kitchen and dining areas Shops Recreational areas Music rooms Mechanical equipment rooms Toilet areas Exterior of building Large music or drama areas Music practice rooms Language laboratories Counseling offices Adjacent music or drama rooms Corridor or public areas Practice rooms Shops Recreational areas Laboratories Toilet areas Mechanical equipment rooms Exterior of building Adjacent practice rooms Corridors and public areas Same as for theaters, concert halls, auditoriums, etc. Same as for executive offices Sound Isolation Requirement (Min.) STC 48-55* STC 50-57* STC 45-52* STC 48-55* STC 58-65* STC STC 40-48* STC 42-50* STC 45-52* STC 45-52* STC STC 42 STC 48 STC 48 STC 42 STC 47 STC 52+ STC 52+ STC 52+ STC 55+ STC 47 STC STC 52+ STC 52 STC 52+ STC 57 STC 57 STC 52 STC 52 STC STC 47+ STC 52+ STC 52+ Any occupancy where serious performances are given (requirements may be relaxed for elementary schools or other types of occupancy) Theaters, concert halls, lecture halls, radio, TV, recording studios Adjacent similar areas Corridors and public area Recreational areas Mechanical equipment spaces Classrooms Laboratories Shops Toilet areas Exterior of building Use qualified acoustical consultants to assist in the design of construction details for these critical occupancies From The American Institute of Architects; Architectural Graphic Standards, Seventh Edition, pp 68 & 69. * Depends on nighttime, exterior background levels and other factors that affect actual location of building. (Grades I, II, and III are discussed in A Guide to Airborne, Impact and Structure borne Noise Control in Multifamily Dwellings, HUD-TS-24, 1974, pp. 10-9ff.) Discretionary depends on client s budget, climate, interior planning (closed vs. open), site planning, and other factors. Use qualified acoustical consultants for analysis of high noise outdoor environments such as airport areas, industrial facilities, and highways. The STC ratings shown are guidelines only.these situations require, typically, double layer construction with resilient connections between layers or, preferably, structurally independent, room-within-a-room constructions.the level of continuous background noise, such as that provided by the HVAC system or an electronic masking system, has a significant impact on the quality of construction selected and must be coordinated with the other design parameters. 6
9 Guide Specification for Fiber Glass Acoustical Insulation Part 1 General 1.01 Summary A. Provide glass fiber acoustical insulation as indicated in building plans Materials Provided in Other Sections These sections are typically cross referenced. Delete sections not included in project manual A. Section Gypsum Board B. Section Gypsum Board Systems C. Section Metal Support Systems 1.03 References A. ASTM Standards 1. E 90, Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions 2. E 413, Rating Sound Insulation 3. E 84,Test Method for Surface Burning Characteristics of Building Materials 4. E 119, Method for Fire Tests of Building Construction Materials 5. E 136,Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 C 6. C 518,Test Method for Steady State Thermal Transmission Properties by Means of the Heat Flow Meter 7. C 665, Specification for Mineral Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing 1.04 Submittals Product Data: Submit manufacturer s product literature, samples and installation instructions for specified insulation Delivery, Storage and Handling A. Protect insulation from physical damage and from becoming wet, soiled, or covered with ice or snow. Comply with manufacturer s recommendations for handling, storage and protection during installation. B. Label insulation packages to include material name, production date and/or product code Delete paragraph below if sections or are not included in project manual. [C. Deliver and store materials under provision of section (01600) (01620).] 1.06 Limitations A. Do not use unfaced insulation in exposed applications where there is potential for skin contact and irritation. Part 2 Products 2.01 Manufacturer Name of insulation manufacturer 2.02 Material Specify name of fiber glass insulation. A. Type: Unfaced glass fiber acoustical insulation complying with ASTM C 665. B. Combustion Characteristics: Passes ASTM E 136 test. C. Surface Burning Characteristics: 1. Maximum flame spread: Maximum smoke developed: 50 When tested in accordance with ASTM E 84.* D. Fire Resistance Ratings: Passes ASTM E 119 test. E. Sound Transmission Class of the assembly: STC F. Size of the insulation Thickness Width Length 2.03 Gypsum Board A. Refer to Section (09250) (09260) for detailed specifications. Select appropriate construction [B. Type: 1/2 thick, type x gypsum panels.] [C. Type: 5/8 thick, type x gypsum panels.] 2.04 Metal Framing A. Refer to Section (09250) (09260) for detailed specifications. Select appropriate construction [B. Type: 2-1/2 steel stud.] [C. Type: 3-5/8 steel stud.] Part 3 Execution 3.01 Inspection and Preparation A. Examine substrates and conditions under which insulation work is to be performed.a satisfactory substrate is one that complies with requirements of the section in which substrate and related work is specified. B. Obtain installer s written report listing conditions detrimental to performance of work in this section. Do not proceed with installation until unsatisfactory conditions have been corrected. C. Clean substrates of substances harmful to insulation Installation - General A. Comply with manufacturer s instructions for particular conditions of installation in each case. B. Batts may be friction-fit in place until the interior finish is applied. Install batts to fill entire stud cavity. If stud cavity is less than 96 in height, cut lengths to friction-fit against floor and ceiling tracks.walls with penetrations require that insulation be carefully cut to fit around outlets, junction boxes and other irregularities. C. Where insulation must extend higher then 8 feet, supplementary support can be provided to hold product in place until the interior finish is applied. * This standard is used solely to measure and describe the properties of products in response to heat and flame under controlled conditions. These numerical ratings are not intended to reflect hazards presented by this or any other material under actual fire conditions.values are reported to the nearest fire rating. 7
10 Single Wood Stud Walls STC-38 (Figure 1) Single 2x4 wood studs, 16" o.c., single layer 1 2" gypsum board each side, one thickness (3 1 2"- 4") fiber glass batt insulation. Fire rating - NR. Single Finish 1A 1 2" GB Single hr. 1B 5 8" Type X GB Single 34 1 hr. 1C 5 8" Type X GB Single 38 (est.) 1 hr. 1D Studs 24" o.c. Single 40 (est.) 1 hr. 5 8" Type X GB STC-40 (Figure 2) Single 2x4 wood studs, 16" o.c., single layer 1 2" gypsum board one side, double layer other side, one thickness (3 1 2"- 4") fiber glass batt insulation. Fire rating - NR Unbalanced Finish 2A 1 2" GB Unbal. 38 NR 2B 5 8" Type X GB Unbal. 38 (est.) 1 hr. (est.) 2C 5 8" Type X GB Unbal hr. (est.) STC-45 (Figure 3) Single 2x4 wood studs, 16" o.c., double layer 1 2" Type X gypsum board each side, one thickness (3 1 2"- 4") fiber glass batt insulation. Fire rating - 1 hr. Balanced Finish 3A 1 2" Type X GB Balanced 39 1 hr. (est.) 3B Studs 24" o.c. Balanced 39 1 hr. (est.) 1 2" Type X GB STC-50 (Figure 4) Single 2x4 wood studs, 16" o.c., with resilient channel, single layer 5 8" Type X gypsum each side, one thickness (3 1 2"- 4") fiber glass batt insulation. Fire rating - 1 hr. Single Finish 4A 1 2" GB Single 39 NR 4B 5 8" Type X GB Single 40 1 hr. 4C 1 2" GB Single 47 NR 4D Studs 24" o.c. Single 52 1 hr. 5 8" Type X GB * Single one wall finish each side Unbalanced one wall finish one side, two wall finishes other side Balanced two wall finishes each side. Partitions with STC ratings within 1-2 points of the listed criteria are acceptable given the anticipated tolerances in repeat tests. In fact, discrepancies between testing labs of 1-2 db on identical configurations are not unusual. (Subjectively, the human ear would consider a 1-2 db change as non-discernible at best, which is insignificant.) 8 Typical Wall Assemblies
11 STC-52 (Figure 5) Single 2x4 wood studs, 16" o.c., with resilient channel, single layer 1 2" gypsum board one side, double layer other side, one thickness (3 1 2"- 4") fiber glass batt insulation. Fire rating - NR Unbalanced Finish 5A 1 2" GB Unbal. 44 NR 5B 5 8" Type X GB Unbal. 48 (est.) 1 hr. 5C Studs 24" o.c. Unbal. 55 NR 1 2" GB STC-55 (est.) (Figure 6) Single 2x4 wood studs, 16" o.c., with resilient channel, double layer 1 2" Type X gypsum board each side, one thickness (3 1 2"- 4") fiber glass batt insulation. Fire rating - 1 hr. Balanced Finish 6A 1 2" Type X GB Balanced 52 1 hr 6B Studs 24" o.c. Balanced 57 1 hr. (est.) 1 2" Type X GB Staggered Wood Stud Walls STC-50 (Figure 7) Staggered 2x4 wood studs, 16" o.c., 2x6 top and bottom plates, single layer 1 2" Type X gypsum board each side, two thicknesses (2 1 2") fiber glass batt insulation. Fire rating - 1 hr. Single Finish 7A 1 2" GB Single 39 NR 7B 4 5 8" Type X GB Single 3 1 hr. 7C 1 2" GB Single 49 NR One thickness of 7D 5 8" Type X GB Single 51(est.) 1 hr. Two thicknesses of (2 1 2") fiber glass batt 7E Studs 24" o.c. Single 52 1 hr. (est.) 1 2" Type X GB One thickness of STC-53 (Figure 8) Staggered 2x4 wood studs, 24" o.c., 2x6 top and bottom plates single layer 1 2" gypsum board one side, double layer other side, one thickness (3 1 2"- 4") fiber glass batt insulation. Fire rating - NR Unbalanced Finish 8A 1 2" GB Unbal. 47 NR 8B Studs 16" o.c. Unbal. 51 NR 1 2" GB * Single one wall finish each side Unbalanced one wall finish one side, two wall finishes other side Balanced two wall finishes each side. Partitions with STC ratings within 1-2 points of the listed criteria are acceptable given the anticipated tolerances in repeat tests. In fact, discrepancies between testing labs of 1-2 db on identical configurations are not unusual. (Subjectively, the human ear would consider a 1-2 db change as non-discernible at best, which is insignificant). 9 Typical Wall Assemblies (continued)
12 STC-55 (Figure 9) Staggered 2x4 wood studs,24" o.c.,double layer 1 2" Type X gypsum board each side,one thickness (3 1 2"- 4") fiber glass batt insulation. Fire rating - 1 hr. (est.) Balanced Finish 9A 1 2" Type X GB Balanced 52 1 hr. (est.) 9B Studs 16" o.c. Balanced 53 1 hr. (est.) 1 2" Type X GB 9C Studs 16" o.c. Balanced 53 2 hr. 5 8" Type X GB Double Wood Stud Walls STC-57 (est.) (Figure 10) Double 2x4 wood studs,16" o.c.,single layer 1 2" Type X gypsum board one side,two thicknesses (3 1 2"- 4") fiber glass batt insulation. Fire rating - 1 hr. Single Finish 10A 1 2" GB, Single 46 NR 10B 5 8" Type X GB Single 45 1 hr. 10C 1 2" GB. One thickness Single 56 NR of 10D 5 8" Type X GB Single 56 1 hr. One thickness of 10E Studs 24" o.c., 1 2" GB Single 56 NR One thickness of ( ") fiber glass batt 10F Studs 24" o.c., 1 2" GB Single 60 NR Two thicknesses of STC-60 (Figure 11) Double 2x4 wood studs, 16" o.c., single layer 1 2" Type X gypsum board one side, double layer other side, two thicknesses (3 1 2"- 4") fiber glass batt insulation. Fire rating - 1 hr. Unbalanced Finish 11A 1 2" GB Unbal. 46 NR 11B 5 8" Type X GB Unbal hr. 11C 1 2" GB Unbal. 56 NR One thickness of 11D Studs 24" o.c. Unbal. 64 NR 1 2" GB Two thicknesses of STC-63 (Figure 12) Double 2x4 wood studs, 16" o.c., double layer 1 2" Type X gypsum board each side, two thicknesses (3 1 2"- 4") fiber glass batt insulation. Fire rating - 1 hr. Balanced Finish 12A 1/2" Type X GB Balanced 54 1 hr. 12B 1 2" Type X GB Balanced 64 1 hr. One thickness of 12C Studs 24" o.c. Balanced 65 NR 1 2" GB One thickness of * Single one wall finish each side Unbalanced one wall finish one side, two wall finishes other side Balanced two wall finishes each side. Partitions with STC ratings within 1-2 points of the listed criteria are acceptable given the anticipated tolerances in repeat tests. In fact, discrepancies between testing labs of 1-2 db on identical configurations are not unusual. (Subjectively, the human ear would consider a 1-2 db change as non-discernible at best, which is insignificant.) 10 Typical Wall Assemblies (continued)
13 Metal Stud Walls STC-45 (Figure 13) 2 1 2" metal studs (25 gauge), 24" o.c., single layer 1 2" gypsum board each side, one thickness (2 1 2"-2 3 4") fiber glass batt insulation. Fire rating - NR Single Finish 13A 1 2" GB Single 36 NR 13B 5 8" Type X GB Single 39 1 hr. 13C 5 8" Type X GB Single 47 1 hr. (2 1 2"-2 3 4") fiber glass batt STC-50 (Figure 14) 2 1 2" metal studs (25 gauge), 24" o.c., single layer 1 2" gypsum board each side, double layer other side, one thickness (2 1 2"-2 3 4") fiber glass batt insulation. Fire rating - NR Unbalanced Finish 14A 1 2" GB Unbal. 39 NR 14B 5 8" Type X GB Unbal hr. 14C 5 8" Type X GB Unbal hr. (2 1 2"-2 3 4") fiber glass batt. STC-54 (Figure 15) 2 1 2" metal studs (25 gauge), 24" o.c., double layer 1 2" gypsum board each side, one thickness (2 1 2"-2 3 4") fiber glass batt insulation. Fire rating - NR Balanced Finish 15A 1 2" Type X GB Balanced 45 2 hr. 15B 5 8" Type X GB Balanced 48 2 hr. 15C 5 8" Type X GB Balanced 57 2 hr. (2 1 2"-2 3 4") fiber glass batt STC-47 (Figure 16) 3 5 8" metal studs (25 gauge), 24" o.c., single layer 1 2" Type X gypsum board each side, one thickness (3 1 2"- 4") fiber glass batt insulation. Fire rating - 1 hr. Single Finish 16A 1 2" GB Single 39 NR 16B 5 8" Type X GB Single 39 1 hr. 16C 5 8" Type X GB Single 50 1 hr.. * Single one wall finish each side Unbalanced one wall finish one side, two wall finishes other side Balanced two wall finishes each side. Partitions with STC ratings within 1-2 points of the listed criteria are acceptable given the anticipated tolerances in repeat tests. In fact, discrepancies between testing labs of 1-2 db on identical configurations are not unusual. (Subjectively, the human ear would consider a 1-2 db change as non-discernible at best, which is insignificant). 11 Typical Wall Assemblies (continued)
14 STC-52 (Figure 17) 3 5 8" metal studs (25 gauge), 24" o.c., single layer 1 2" gypsum board one side, double layer other side, one thickness (3 1 2"- 4") fiber glass batt insulation. Fire rating - NR Unbalanced Finish 17A 1 2" GB Unbal. 42 NR 17B 5 8" Type X GB Unbal hr. 17C 5 8" Type X GB Unbal hr. STC-56 (Figure 18) 3 5 8" metal studs (25 gauge), 24" o.c., double layer 1 2" Type X gypsum board each side, one thickness (3 1 2"- 4") fiber glass batt insulation. Fire rating - 2 hr Balanced Finish 18A 1 2" Type X GB Balanced 50 2 hr. 18B 5 8" Type X GB Balanced 52 2 hr. 18C 5/8" Type X GB Balanced 58 2 hr. Exterior Walls STC-47 (Figure 19) Exterior frame wall, 5 8"x10" redwood siding 1 2" sheathing, 2x4 studs, 16" o.c., resilient channel, 1 2" gypsum board, one thickness (3 1 2"- 4") fiber glass batt insulation. Fire Rating - NR Variation Construction STC Fire Rating 19A 43 NR 19B No resilient channel 39 NR 19C No resilient channel 37 NR STC-57 (Figure 20) Exterior 7 8" stucco, 1" woven mesh and no.15 felt paper and, 2x4 studs, 16" o.c., resilient channel, 1 2" gypsum board, one thickness (3 1 2"- 4") fiber glass batt insulation. Fire Rating - NR Variation Construction STC Fire Rating 20A 49 NR 20B No resilient channel 46 NR * Single one wall finish each side Unbalanced one wall finish one side, two wall finishes other side Balanced two wall finishes each side. Partitions with STC ratings within 1-2 points of the listed criteria are acceptable given the anticipated tolerances in repeat tests. In fact, discrepancies between testing labs of 1-2 db on identical configurations are not unusual. (Subjectively, the human ear would consider a 1-2 db change as non-discernible at best, which is insignificant.) 12 Typical Wall Assemblies (continued)
15 * Single one wall finish each side Unbalanced one wall finish one side, two wall finishes other side Balanced two wall finishes each side. Partitions with STC ratings within 1-2 points of the listed criteria are acceptable given the anticipated tolerances in repeat tests. In fact, discrepancies between testing labs of 1-2 db on identical configurations are not unusual. (Subjectively, the human ear would consider a 1-2 db change as non-discernible at best, which is insignificant). STC-58 (Figure 21) Exterior brick veneer, 1 2" air space, 3 4" insulative sheathing, 2x4 studs, 16" o.c., resilient channel, 1 2" gypsum board, one thickness (3 1 2"- 4") fiber glass batt insulation. Fire Rating - NR Variation Construction STC Fire Rating 21A 54 NR 21B No resilient channel 56 NR STC-40 (Figure 22) Exterior 7 16"x10" hardwood lap siding 7 16" foil faced foam sheathing, 2x4 studs, 16" o.c., 1 2" gypsum board, one thickness (3 1 2"- 4") fiber glass batt insulation. Fire Rating - NR 22A 36 NR STC -39 (Figure 23) Exterior 7 16"x10" hardwood lap siding, 7 16" foil faced foam sheathing, 2x6 studs, 16" o.c., 1 2" gypsum board, one thickness (5 1 2") fiber glass batt insulation. Fire Rating - NR Variation Construction STC Fire Rating 23A 38 NR 23B With resilient channel 45 NR (5 1 2") fiber glass batt 13 Typical Wall Assemblies (continued)
16 STC-53 IIC-73 (Figure 25) Wood Floor Carpet and pad, 3 8" particle board, 5 8" plywood subfloor, 2x10 joists 16" o.c., one thickness (3 1 2"- 4") fiber glass batt insulation, resilient channel, 1 2" Type X gypsum board. Fire Rating - 1 hr. Variation Construction IIC STC Fire Rating 25A No resilient channel NR 25B 1 2" plywood floor NR 5 8" plywood subfloor 25C Vinyl floor NR instead of carpet and pad STC-58 IIC-74 (Figure 26) Concrete Floor Carpet and pad, 1 1 2" lightweight concrete floor, 5 8" plywood subfloor, 2x10 joists 16" o.c., one thickness (3 1 2"- 4") fiber glass batt insulation, resilient channel, 1 2" Type X gypsum board. Fire Rating - 1 hr. est. Variation Construction IIC STC Fire Rating 26A No resilient channel NR 26B 2x8 joists, NR 1 5 8" lightweight concrete floor 26C 2x8 joists, NR Vinyl floor instead of carpet and pad STC-56 IIC-71 (Figure 27) Steel Joist Floor Carpet and pad, 3 4" T&G plywood subwood subfloor, steel joists (7 1 4", 18 ga.) 24" o.c., one thickness (3 1 2"- 4") fiber glass batt insulation, resilient channel, 5 8" gypsum board. Fire Rating - NR Variation Construction IIC STC Fire Rating 27A No resilient channel NR STC-51 IIC-78 (Figure 28) Plywood Floor Carpet and pad, 5 8" plywood floor, 2" x 3" furring, 1 2" sound deadening board, 1 2" plywood subfloor, 2x8 wood joists, one thickness (3 1 2"- 4") fiber glass batt insulation, 5 8" Type X gypsum board. Fire Rating - NR Variation Construction IIC STC Fire Rating 28A With vinyl floor NR instead of carpet and pad * Single one wall finish each side Unbalanced one wall finish one side, two wall finishes other side Balanced two wall finishes each side. Partitions with STC ratings within 1-2 points of the listed criteria are acceptable given the anticipated tolerances in repeat tests. In fact, discrepancies between testing labs of 1-2 db on identical configurations are not unusual. (Subjectively, the human ear would consider a 1-2 db change as non-discernible at best, which is insignificant.) 14 Typical Floor/Ceiling Assemblies
17 Recommended Construction Methods for Controlling Sound Doors Stagger doors across hallways and use gasketing. Avoid sliding doors in areas where sound control is desired. Use doors of solid wood or insulated cores wherever privacy is an important consideration; hollowcore doors will not be as effective. Hollow core door, no gaskets, 1/4 air gap at sill Apt. A POOR Apt. B Hall with hard floor & ceiling Apt. C Apt. D Solid core door with gaskets and drop closure Apt. A Hall with carpet & acoustic ceiling Apt. C Apt. D BETTER Apt. B Open metal strip Solid rubber strip Rubber tube Apt. A Apt. B Hall with hard floor & ceiling Apt. D Apt. C Automatic drop DOOR JAMB GASKETS Lap joint Tube gasket in sill Sweep strip BEST DOOR SILL CLOSURES Windows Minimize the size of windows facing noisy areas. Separate windows to reduce cross-talk. 1/8 Glass Movable windows casement or double hung Felt or rubber perim. gaskets 1/4 Plate glass Arrange casement windows so sound is not reflected into adjoining units. Make sure movable windows close tightly and are weather-stripped. Use thick glass, insulating glass or storm windows to help reduce sound transmission through windows. Siding POOR Wood stud wall Brick veneer Fixed windows FAIR Wood stud wall 7/32 Plate glass 7/16 3-Ply laminated glass Felt or rubber perim. gaskets 1/4 Plate glass Felt or rubber perim. gaskets Perim. acoustic lining GOOD Brick/masonry wall Brick/masonry wall VERY GOOD Resil. Channel Wiring Dishwasher Wire each apartment as a unit; avoid penetration of walls or floors between apartments. Caulk holes (made by wiring) that penetrate connecting structures; use elastic, non-hardening caulk or dry packing. Connect vibrating equipment with flexible wiring. Flexible loop drapes in position Isolation mounts 15
18 Electrical Outlets Cut holes neatly to reduce leaks. Make sure outlets are airtight by using elastic, non-hardening caulk before installing the plates. Don t install electrical outlets back to back. Switch or electrical outlet. Use quiet type light switches throughout apts., particularly in party walls. 3 min. DO Discourage placement of TV sets against party walls by providing TV antenna, outlets in non-party walls. Avoid recessed back-to-back mounting of electrical outlets. Electrical outlets Antenna outlets DON T Ceiling Fixtures Floor assembly Surface mount any ceiling fixtures on resiliently mounted gypsum ceilings. Wood baffle Make sure openings around boxes are sealed air tight. Spring mounting Light fixture isolated from ceiling Don t use recessed or hi-hat type fixtures without boxing in the fixture. Suspended ceiling Glass Caulk edges DO Floor assembly Wood baffle Fluorescent light Spring mounting Fluorescent light with open grille Glass Suspended ceiling DO Floor assembly Spring mounting Light fixture bridges across ceiling and joist thus shorting spring mount Suspended ceiling DON T Electrical Distribution Panels Install these panels on interior walls within apartments and never on corridor or party walls. 16
19 Plumbing Design pipe runs with swing arms so expansion and contraction can occur without binding, thus eliminating noise. Isolate piping from structures with resilient pads and sleeves, then seal for air tightness. Develop a well-planned layout to minimize the noise of flowing water. Use oversized pipes and reduced pressures to slow the speed of flowing water and reduce noise. Provide air chambers to eliminate water hammer due to abrupt stopping of flowing water. Use quiet-action water closets that are isolated from the structure on a floating floor. Caulk all openings made in walls, floors and framing for supply and drain lines. GOOD LAYOUT IS CHEAPER Pack with fiber glass Seal air tight with flexible seal AIR CHAMBER Metal hanger Fiber glass pipe insulation Isolation Pad Vibration isolation supports Angle iron bracket Sound absorbing board walls Appliances and Air Conditioners Select quiet, high-quality appliances. Use adequately-sized water piping and valves to minimize whistling. Select quiet air conditioners with balanced fans and motors. Select quiet external ballast on fluorescent fixtures. Phones and Other Noise-Making Equipment Install phones, doorbells, intercoms, etc., on interior walls only never on party walls or corridor walls. 17
20 Insulated Duct Systems Use performed fiber glass ducts or fiber glass duct liners to quiet fan noise and the sounds of air rushing through the ducts. See chart below for an acoustical comparison between uninsulated (bare) ducts and various types of insulated ducts. For more information on insulated duct systems contact NAIMA and request a copy of publication number: AH121, A Guide to Insulated Duct Systems. Duct Noise Attenuation Loss (db/lf) Medicine Cabinets Separate or surface mount medicine cabinets or install mirrors on party walls with medicine cabinets on interior partitions. 18 Outer metal wall Sound Frequency Description Bare Sheet Metal No perceived noise reduction. Wrapped Sheet Metal No perceived noise reduction. Lined Sheet Metal (1 thick) 2 Significant perceived noise reduction. Fiber Glass Air Duct (1 thick) 3 Very significant reduction. Perceived noise reduced to less than 1 2 original level. 1.Version 1.1, 1978 ASHRAE Transactions,Vol 84, Part 1, p ASHRAE HVAC Systems & Applications HandBook, 1987, Ch Noise Control Manual, O.C. 6th Edition, 1986 Cabinet Cabinet Cabinet Gypsum Board DO - Stagger Cabinet DO - Surface Mounting Cabinet Cabinet DON T Glass wool blanket Inner metal wall Acoustic lining Fiber glass blanket Fiber glass blanket Avoid recessed, back-to-back mounting of cabinets in party walls
21 Equipment Noise Locate heating and cooling equipment far from bedrooms. Living room Bath Bedroom Inquire about equipment noise levels before buying and insist on quiet units. Dining room Kitchen Bedroom Isolate equipment in rooms with a door to the outside or use a gasketed, solid-core door when access is from building interior Balcony POOR Mount equipment so as to keep vibrations from entering surrounding structures. Construct partitions separating living units from equipment rooms with an STC of 50 or better Living room Bath Bedroom Dining room Kitchen Bedroom Wall Bases Install plates on sill sealers; run wall finish to floor where possible and caulk airtight on both sides. Balcony BETTER Living room Bath Bedroom Cracks in Floor Seal all cracks in the subfloor airtight with caulking. Dining room Kitchen Bedroom Balcony BEST Ceiling Outside vent l Solid-core door Acoustic tile Supply Acoustic lining Furnace and A/C unit Return Grille Rubber gasket Staggered stud wall or masonry walls Vibration isolators Mounting plate Flexible connections Floor 19
22 Glossary Absorption The ability of a material to absorb rather than reflect sound waves striking it by converting sound energy to heat energy within the material. Acoustics The science of sound, including its production, transmission and effects. Airborne Sound Sound, produced by vibrating sources that radiate sound directly into the air, which is transmitted through air as a medium rather than through solids or the structure of the building. Background Noise Normal sound always present in a space created either by outdoor sounds such as street traffic or indoor sounds such as ventilating noise, appliances, etc. Decibel Logarithmic unit expressing the ratio between a given sound being measured and a reference point. Discontinuous Construction Any of several construction methods, such as the use of staggered studs, double walls, or resilient mounting of surfaces, used to break the continuous paths through which sound may be transmitted. Flanking Paths A wall or floor/ceiling construction that permits sound to be transmitted along its surface; or any opening which permits the direct transmission of sound through the air. Frequency The number of complete cycles of a vibration performed in one second, measured in cycles per second (cps) and expressed in Hertz (Hz). Hertz (Hz) A unit of frequency of a periodic process equal to one cycle per second. Impact Insulation Class (IIC) A single number rating developed by the Federal Housing Administration to estimate the impact sound isolation performance of floor/ceiling systems. Noise Unwanted sound. Noise Reduction Reducing the level of unwanted sound by any of several means of acoustical treatment. Noise Reduction Coefficient A single number index of the noise reducing efficiency of acoustical materials. It is found by averaging the sound absorption coefficients at 250, 500, 1000 and 2000 cps. Sound A vibration in any elastic medium within the frequency range capable of producing the sensation of hearing. Sound Attenuation Reduction of the energy or intensity of sound. Sound Transmission The passage of sound through a material construction or other medium. Airborne Sound Transmission: Sound transmitted when a surface is set into vibration by the alternating air pressures of incident sound waves. Sound Transmission Class (STC) A single number rating for evaluating efficiency of constructions in isolating airborne sound transmission. The higher the STC rating the more efficient the construction. Transmission Loss The decrease or attenuation in sound energy (expressed in decibels) of airborne sound as it passes through a building construction. 20
23 Bibliography CertainTeed Corp., Fire Resistance and Sound Control Guide. Available from CertainTeed Corp. P.O. Box 860, Valley Forge, Pennsylvania Knauf Fiber Glass, The Sound Solution. Available from Knauf Fiber Glass, One Knauf Drive, Shelbyville, Indiana Loney, W., Effect of Cavity Absorption on the Sound Transmission Loss of Steel Stud Gypsum Wallboard Partitions, The Journal of Acoustical Society of America, Vol. 49, No.2, Loney, W., Effect of Cavity Absorption and Multiple Layers of Wallboard on the Sound Transmission Loss of Steel Stud Gypsum Wallboard Partitions, The Journal of Acoustical Society of America,Vol. 53, No. 6, Halliwell. R. E. and Quirt, J. D., Controlling Interoffice Sound Transmission Through a Suspended Ceiling, The Journal of Acoustical Society of America,Vol. 90, Sept NAHB Research Foundation, Inc., Insulation Manual/Home, Apartments - Second Edition. Available from NAIMA, 44 Canal Center Plaza, Suite 310,Alexandria, VA Office of Noise Control, California Department of Health Services, Catalog of STC and IIC Ratings for Wall and Floor/Ceiling Assemblies, 2151 Berkeley Way, Berkeley, California Owens Corning, Noise Control Design in Residential Construction Available from Owens Corning, One Owens Corning Parkway,Toledo, OH Johns Manville, Sound Control. Available from Johns Manville, PO Box 5108, Denver, Colorado The American Institute of Architects, Architectural Graphic Standards, Seventh Edition, Sound Isolation Design Criteria Table. Ramsey/Sleeper, Reprinted by permission of John Wiley & Sons, Inc. U.S. Department of Commerce, NBC HandBook 119, Quieting: A Practical Guide to Noise Control, July Available from Superintendent of Documents, U.S. Government Printing Office,Washington, DC U.S. Department of Commerce, National Bureau of Standards, Acoustical and Thermal Performance of Exterior Residential Walls, Doors and Windows. NBS Building Sciences 77, November 1975.Available from Superintendent of Documents, U.S. Government Printing Office,Washington, DC
24 ABOUT NAIMA NAIMA is a trade association of North American manufacturers of fiber glass, rock wool, and slag wool insulation products. NAIMA s role is to promote energy efficiency and environmental preservation through the use of fiber glass, rock wool, and slag wool insulation products and to encourage safe production and use of these insulation products. NAIMA Building Insulation Committee: CertainTeed Corporation, 800/ E. Swedesford Road, Valley Forge, PA Johns Manville, 800/ P.O. Box 5108, Denver, CO Knauf Fiber Glass, 800/ One Knauf Drive, Shelbyville, IN Owens Corning, 800/GET-PINK One Owens Corning Parkway, Toledo, OH For additional information contact to: NAIMA 44 Canal Center Plaza Suite 310 Alexandria, Virginia Tel: 703/ Fax: 703/ [email protected] Website: PUB # BI405 12/97
Lightweight Partition Design for Residential and Commercial Buildings
Lightweight Partition Design for Residential and Commercial Buildings Stanley D. Gatland II, CertainTeed Corporation, Valley Forge, Pennsylvania Guidelines are presented for the design and proper installation
Fiberglas, Exterior Wall Thermal Insulation
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
Controlling the Transmission of Impact Sound through Floors
Construction Technology Update No. 35 Controlling the Transmission of Impact Sound through Floors by A.C.C. Warnock This Update presents guidelines for controlling the transmission of impact sound through
EcoTouch Insulation with PureFiber Technology
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
The Role of Acoustics in Curtain Wall Design:
The Role of Acoustics in Curtain Wall Design: Strategies to Achieve Desired Performance Criteria April 22, 2015 John LoVerde, Principal VENEKLASEN ASSOCIATES, INC. Goals Basics of Acoustics Ratings in
This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
2014 British Columbia Building Code Changes
District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most
Underwriters Laboratories Testing Information
Underwriters Laboratories Testing Information R-8078 Underwriters Laboratories Inc. R-13173 Classified Spray Fiber Surface burning characteristics applied to inorganic reinforced cement board with a maximum
Acoustical Doorway Solutions
Acoustical Doorway Solutions Sound Transmission Control for Any Facility Brought to you by ASSA ABLOY Group brands: BARON CECO DOOR CURRIES FRAMEWORKS GRAHAM MAIMAN PEMKO SMP SPECIALTY DOORS Who We Are
Acoustical Design Guidelines for HVAC Systems in Schools
Acoustical Design Guidelines for HVAC Systems in Schools Seminar 9, ASHRAE Summer Meeting Albuquerque, New Mexico Sponsor: TC 2.6 Sound and Vibration Robert M. Lilkendey Associate Principal Consultant
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional
SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS
NOISE TECHNICAL FACT SHEET FACT SHEET 5 SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS The sound insulation of exterior walls and roof-ceiling systems refers to their ability to reduce external
INTER-NOISE 2006 3-6 DECEMBER 2006 HONOLULU, HAWAII, USA
INTER-NOISE 2006 3-6 DECEMBER 2006 HONOLULU, HAWAII, USA An effective new approach to isolate plumbing stub-outs in residential construction Jeffrey P. Kwolkoski, P.E., INCE Bd. Cert. a D. L. Adams Associates,
Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman.
Building Type Building Code Whitley Classroom Buildings BOCA, UBC, SBCCI, NEC, ADA Structural Support Outrigger construction standard, Whitley model classrooms. Main support beams to be 12 11.8# per lineal
Case Studies Illustrating Acoustic Design Guidelines for HVAC Systems in Schools
Cleveland, Ohio NOISE-CON 2003 2003 June 23-25 Case Studies Illustrating Acoustic Design Guidelines for HVAC Systems in Schools Robert M. Lilkendey, Siebein Associates, Inc. 625 NW 60 th Street, Suite
Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen
Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen May 2008 Wisconsin Area PO BOX 115 Lake Geneva, WI 53147 CELL (414) 550-4765 Home Performance with ENERGY STAR Evaluation Report Customer
Mass Loaded Vinyl A review of the performance and cost in acoustical applications
Mass Loaded Vinyl A review of the performance and cost in acoustical applications Overview Driven by building codes and occupants expectations, many rooms in commercial and residential construction require
Retrofit structural insulated panels (SIPs) increase sound transmission loss of existing single family houses impacted by highway noise
Baltimore, Maryland NOISE-CON 2010 2010 April 19-21 Retrofit structural insulated panels (SIPs) increase sound transmission loss of existing single family houses impacted by highway noise Scott Harvey
H-Stud Area Separation Wall System
12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic
Fundamentals of Acoustics & Practical HVAC Design Considerations. Demir Doken Acoustic Engineer
Fundamentals of Acoustics & Practical HVAC Design Considerations Demir Doken Acoustic Engineer What is sound? Sound is a mechanical wave that is an oscillation of pressure transmitted through some medium
EVERYTHING YOU WANTED TO KNOW ABOUT SOUND BUT WERE AFRAID TO HEAR.
WHAT IS SOUND? EVERYTHING YOU WANTED TO KNOW ABOUT SOUND BUT WERE AFRAID TO HEAR. Sound waves travel through the air in the form of very small changes in atmospheric pressure. Sound pressure (which we
fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors
fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors Roxul Safe n Sound Sound Control and Fire Safety From One Batt Insulation Roxul
CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov
CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov Finishing a basement to make additional living space in a house is a popular construction project for many homeowners.
1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability
1/9/13 By Brett T. Fagan, P.E. Presented by Marie Horan, P.E. Building Diagnostics, Inc. Building Diagnostics Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability
State of Connecticut Department of Public Health RADON PROGRAM
State of Connecticut Department of Public Health RADON PROGRAM Scope The Connecticut Department of Public Health (DPH) Radon Program is providing this information for contractors who decide to build radon
Gramercy Place Condo Association, Inc.
Gramercy Place Condo Association, Inc. UNIT MODIFICATION REQUEST Date of Application: Name of Owner (s): Telephone: (Home) (Cell) E-Mail: Anticipated start date: Anticipated ending date: Permission is
Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.
Fire & Soundproofing Insulation Roxul SAFE N SOUND Fire and Soundproofing Insulation for Interior Partition Walls and Floors. Roxul SAFE N SOUND Sound control and fire safety from one batt Insulation.
In today s architectural environment, good acoustical design isn t a luxury
USG Presents by: James D. Janning, AIA, CSI Architectural Systems Manager, USG Corporation In today s architectural environment, good acoustical design isn t a luxury it s a necessity. Acoustics impacts
SECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
SECTION 00 0110 TABLE OF CONTENTS. H. 00 2115.01 - Proposed Material, Product or Equipment Substitution Request
SECTION 00 0110 PROCUREMENT AND CONTRACTING REQUIREMENTS 1.1 DIVISION 00 -- PROCUREMENT AND CONTRACTING REQUIREMENTS A. 00 0101 - Project Title Page B. 00 0105 - Certifications Page C. 00 0110 - Table
Inspecting to a higher standard.
Inspecting to a higher standard. Rob Hopkin Silver Spring, MD 20902 Monday, June 2, 2014 ProTec Inspection Services Inc. 19736 Selby Ave Poolesville, MD 20837 301-972-8531 www.protec-inspections.com [email protected]
bout your apartment SOLVING ODOUR TRANSFER PROBLEMS IN YOUR APARTMENT Understanding Air Movement in Your Building
A bout your apartment SOLVING ODOUR TRANSFER PROBLEMS IN YOUR APARTMENT AE 1 One of the most common problems experienced by the occupants of apartment buildings is the transfer of objectionable odours
Rockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
Gypsum Board Systems Manual
CertainTeed Gypsum Board Systems Manual Fire Resistance and Sound Control Design Manual Division 09 GYPSUM BOARD SYSTEMS MANUAL TABLE OF CONTENTS Introduction General Fire Resistance...1 Sound Control...3
The Acoustical Properties of Wool Carpet
The Acoustical Properties of Wool Carpet... carpet is one of the most practical and cost-effective products available for controlling noise in the built environment. Dianne Williams, Graeme E Harding and
Acoustic Design Practices for Sustainable Buildings
Acoustics 2008 Geelong, Victoria, Australia 24 to 26 November 2008 Acoustics and Sustainability: How should acoustics adapt to meet future demands? Acoustic Design Practices for Sustainable Buildings Danny
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
Color logos Reverse logos Acoustics Black only logos
Acoustics ACOUSTICS General The basic purpose of architectural acoustics is to provide a satisfactory environment in which the desired sounds are clearly heard by the intended listeners and the unwanted
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
Development Services City of Lawrence, KS
Development Services City of Lawrence, KS Building Planning Table R301.2 (1) Climatic & Geographic Design Criteria Building Planning The design criteria for wind speed increased from 90 MPH to 115 MPH.
SODA SPRINGS JOINT SCHOOL DISTRICT NO. 150 RECOMMENDED REPAIRS, REPLACEMENT, AND ADDITIONS OPINIONS OF PROBABLE COST
SODA SPRINGS JOINT SCHOOL DISTRICT NO. 150 RECOMMENDED REPAIRS, REPLACEMENT, AND ADDITIONS OPINIONS OF PROBABLE COST SODA SPRINGS HIGH SCHOOL REPAIRS AND UPGRADES SITE Construction Estimate = $100,000
PDmB, Inc. Definitions
Page 1 of 11 Definitions S Satisfactory Meets industry standards for proper material and installation NP Not Present Condition or item was not present at time of inspection NI Not Inspected Condition or
Single Family Residential Basement Finish
How to Use This Guide Building Guide Pottawattamie County Planning & Development Department Building & Safety Division Single Family Residential Basement Finish Provide two (2) sets of plans and complete
Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com
Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com Portland Area PO Box 665 West Linn, OR 97068 Ph: (503) 650-6957 Salem Area 5434 River Rd. N; #192 Keizer, OR 97303 Ph: (503) 362-5809
MRI RF SHIELDING DESIGN
MRI RF SHIELDING DESIGN Nelco s MRI RF Shielding is specifically designed for the MRI industry. Our engineers have developed a shielded enclosure made entirely of nonmagnetic materials that is unsurpassed
EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money
EASY$ TIP SHEETS Energy Advice Saving Yukoners Money Quick Links How to check for leaks Draftproofing products Sealants Draft proofing your home Draftproofing can be a cost-effective measure you take to
CENTER FOR ENVIRONMENTAL HEALTH Emergency Response/Indoor Air Quality Program
CENTER FOR ENVIRONMENTAL HEALTH Emergency Response/Indoor Air Quality Program Guidance Concerning Remediation and Prevention of Mold Growth and Water Damage in Public Schools/Buildings to Maintain Air
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
Arapahoe County Residential Water Heater Installation and Inspection Guide
Arapahoe County Residential Water Heater Installation and Inspection Guide The attached handout is designed to be a general permit submittal and inspection guide covering most installation instances, however
Best Basement Water Management Practices
Best Basement Water Management Practices Guide written by Patrick Sluss Sluss Construction (330) 224 5394 When a home owner is faced with a leaking basement there is a way to correct the problem and a
SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)
SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME) Construction Criteria The unit costs for ADP Mainframe space types are based on the construction quality and design features in the following
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST
0 RIVERSIDE DRIVE, OTTAWA, ON A0.0 COVER SHEET / DRAWING LIST A0. LEGEND AND GENERAL NOTES A0. GENERAL NOTES A0. GENERAL NOTES A0. TYPICAL WASHROOM WALL/SINK SECTION A0. DETAIL - CONTROL JOINT A0. DETAIL
solutions & tips six Wise Energy Guide Building envelope solutions and simple tips AIR SEALING
Wise Energy Guide solutions & tips 32 AIR SEALING Is your house leaking money? six Building envelope solutions and simple tips If your home is like most, the greatest amount of heat loss is from air leakage;
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
Acoustic expectations, health effects, and design techniques in the urban environment
Acousticexpectations,healtheffects,anddesign techniquesintheurbanenvironment SteveRyherd Abstract The motivation for new urbanism brings with it potential challenges that designers may not have been forced
24.301.161 INCORPORATION BY REFERENCE OF INTERNATIONAL. (1) The Department of Labor and Industry adopts and incorporates by
24.301.161 INCORPORATION BY REFERENCE OF INTERNATIONAL ENERGY CONSERVATION CODE (1) The Department of Labor and Industry adopts and incorporates by reference the International Code Council's International
SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY
SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY Construction Criteria The unit costs for (Wet) space types are based on the construction quality and design features in the following table. This
Building Condition Assessment Report
Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.
2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012
2012 Ontario Building Code Requirements for New Construction Bradford West Gwillimbury Building Division March 5, 2012 1 Ontario Building Code changes Applicable to permits applied for after December 31,
ROOFS, SNOW AND ICE DAMS
ROOFS, SNOW AND ICE DAMS The Problem Ice dams are a common roof performance problem in cold climate buildings. Simply put, they are ridges of ice and icicles caused by melt water from further up the roof
17,280 square feet Overview:
CENTRAL OFFICE Located at 167 Boston Post Road, East Lyme, Connecticut, the Central Office was built in 1916 as the original Flanders Elementary School and remains connected to the current school. The
Value Engineering Considerations for Cast Iron Soil Pipe and PVC in Commercial Sanitary and Storm Drainage Applications
Value Engineering Considerations for Cast Iron Soil Pipe and PVC in Commercial Sanitary and Storm Drainage Applications BR-VEC (2-14-13) The Correct Material for the Correct Application Plumbing design
ROXUL Board Insulation Section 07 21 13 Master Guide Specification (CAVITYROCK ) Page 1 April 2016
Master Guide Specification (CAVITYROCK ) Page 1 Click on the pilcrow in the MS Word Toolbar to toggle ROXUL GUIDE NOTES on and off. Delete this text before incorporating the section into a Project Manual.
Residential Inspection Guidelines
Residential Inspection Guidelines 201 Pre-Pour Foundation Dimensions Building Location Certificate - if required in the building consent Construction and Advice Notes Check the building dimensions against
EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010
EFA PSBP Natural Ventilation Strategy Introduction The Baseline Designs Project will provide scheme design details for a number of Primary and Secondary School Exemplars. For the purposes of setting a
All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal.
2.02 DESIGN DEVELOPMENT PHASE GENERAL The Architect shall prepare the Design Development Documents from the approved Schematic Design. The Design Development Documents shall consist of drawings and other
GYPSUM AREA SEPARATION FIREWALLS GA-620-2011
GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein
Heating Load Calculation
Heating Load Calculation ME 425 Air Conditioning System Design Keith E. Elder, P.E. Heating Load Calculation The heating load calculation begins with the determination of heat loss through a variety of
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to
KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS
St. Louis County Department of Public Works Division of Code Enforcement KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS This guideline is intended to provide the homeowner/contractor with the
[ Between us, ideas become reality. ] Office Acoustics Attaining speech privacy in open and closed plan environments.
CEILING SYSTEMS [ Between us, ideas become reality. ] Office Acoustics Attaining speech privacy in open and closed plan environments. office acoustics The message is loud and clear: office employees have
Acumen Enterprises, Inc.
Hourly rates Discount w/o Rebate Electrician $78.00 10% $70.20 $70.73 HVAC Technician $78.00 10% $70.20 $70.73 Insulator $42.00 10% $37.80 $38.08 Sheet Metal Worker $74.00 10% $66.60 $67.10 Plumber/Pipefitter
Additions and Alterations
Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal
Building Department John Fiedler Construction Official Ext. 211. SAMPLE GUIDE FOR 1&2 FAMILY DWELLING BASEMENTS Rev 4-3-2014
TOWNSHIP OF HILLSBOROUGH COUNTY OF SOMERSET Hillsborough Township Municipal Complex The Peter J. Biondi Building 379 South Branch Road Hillsborough, NJ 08844 P: (908) 369-4313 F: (908) 369-3954 Building
BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207
BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207 SELF EVALUATION CHECKLIST FOR RESIDENTIAL AND MULTI-FAMILY DWELLING INSPECTIONS The attached checklist
BUILDING SAFETY UNIT
POLICY Page 1 of 5 SUBMITTAL REQUIREMENTS FOR ONE AND TWO FAMILY DWELLINGS, ADDITIONS AND RENOVATIONS All submittals shall be site specific and designed to the provisions of the 2012 International Residential
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders
Manual lifting and handling
Manual lifting and handling When installing British Gypsum products and systems care should be taken to ensure that appropriate methods of handling and lifting are adopted. The following guidance details
2009 IECC Update. Scope. Content. International Energy Conservation Code
2009 IECC Update International Energy Conservation Code Scope The code applies to both residential and commercial buildings. In the code, the United States is divided into eight climate zones which are
BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES
Department of Health and Human Services, Division of Public Health Occupational and Environmental Epidemiology Branch 1912 Mail Service Center, Raleigh, North Carolina 27699-1912 BUILDING ASSESSMENT QUESTIONNAIRE
HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663)
HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663) Fire-Retardant-Treated Wood Framed Wall Assemblies GENERAL INFORMATION Fire-resistant construction
Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
Basement Development Construction requirements for the development of basements in residential dwellings.
PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Basement Development Construction requirements for the development of basements in residential dwellings. June 2009 contents GENERAL INFORMATION 3 BUILDING
Excerpts from the Canadian National Building Code (NBC)
Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more
Acoustic Terms, Definitions and General Information
Acoustic Terms, Definitions and General Information Authored by: Daniel Ziobroski Acoustic Engineer Environmental and Acoustic Engineering GE Energy Charles Powers Program Manager Environmental and Acoustic
Mark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
COMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
The Case for Cross Laminated Timber: Part 2
Learning Objectives The Case for Cross Laminated Timber: Part 2 Opportunities and Challenges for a New Class of Timber Product 1. Review answers to common questions regarding the design and construction
Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components
Infrastructure Facility Condition Summary Weighted Avg Condition Score Facility Components Systems Surveyor/ Date Done Comments G Sitework.9 Site Improvements Parking Pedestrian Paving Site Development
How does Architecture Affect the Acoustics of a Space
How does Architecture Affect the Acoustics of a Space Grade Level This lesson plan was developed for a 9 th grade Physical Science Class. Objectives To develop aural senses of spatial awareness To understand
IECC Compliance Guide for Homes in Virginia
IECC Compliance Guide for Homes in Virginia Amended Version of 2012 International Energy Conservation Code July 14, 2014 Climate Zone Since the entire state of Virginia falls in the IECC Climate Zone 4,
Insulation R-Value Comparisons
Insulation R-Value Comparisons American Ingenuity s component panels for the 22 48 domes contains seven inch thick rigid Expanded Polystyrene (E.P.S.) insulation which has an R value of 28. American Ingenuity
DEFAULT HEAT LOSS COEFFICIENTS
DEFAULT HEAT LOSS COEFFICIENTS SECTION A101 GENERAL REQUIREMENTS A101.1 Scope. The following defaults shall apply to Chapter 4 of both the (RE) and (CE) sections of the IECC. This chapter includes tables
Guidelines for Earthquake Bracing Residential Water Heaters
Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the
Building Permits: When are they required?
Building Permits: When are they required? Generally, you need to obtain a building permit from the City whenever you construct, enlarge, alter, repair, move, remove, improve, convert, or demolish a building