User Guidelines for Pressure Area Care Mattresses and Cushions
|
|
|
- Nathan McLaughlin
- 9 years ago
- Views:
Transcription
1 User Guidelines for Pressure Area Care Mattresses and Cushions QUATTRO ACUTE Systems QUATTRO PRIME Systems QUATTRO PLUS Systems QUATTRO OVERLAY Systems PULSAIR CHOICE Systems SUPREMA DORMIRA B.A.S.E. Seating Systems
2 Contents Page INTRODUCTION 1 CAUTIONS AND WARNINGS INFORMATION 2 ALTERNATING AIR PRESSURE MATTRESSES & CUSHIONS INSTALLATION AND USER GUIDELINES 3 CARE AND MAINTENANCE 8 FAULT FINDING 9 FOAM MATTRESSES & CUSHIONS INSTALLATION AND USER GUIDELINES 11 CARE AND MAINTENANCE 11 SPECIFICATIONS 13 Introduction Thank you for choosing to use a Talley Medical pressure area care product, effective for the prevention and management of pressure ulcers. The range of alternating air pressure products is as follows:- QUATTRO ACUTE: mattress replacement system for patients at very high risk of pressure ulcers QUATTRO PRIME: mattress replacement system for patients at very high risk of pressure ulcers QUATTRO PLUS: mattress replacement system for patients at high risk of pressure ulcers QUATTRO OVERLAY: mattress overlay system for patients at high risk of pressure ulcers PULSAIR CHOICE mattress replacement: for patients at high risk of pressure ulcers PULSAIR CHOICE mattress overlay: for patients at medium risk of pressure ulcers PULSAIR CHOICE cushion: seat cushion: for patients at high risk of pressure ulcers B.A.S.E. SEQUENTIAL: seat cushion for patients at very high risk of pressure ulcers* B.A.S.E. RECLINER MAT : seat and back cushion for patients at very high risk of pressure ulcers* The range of static foam products is as follows:- SUPREMA : mattress replacement and cushion for patients at medium risk of pressure ulcers DORMIRA : mattress replacement and cushion for patients at risk of pressure ulcers 1
3 Cautions and Warnings Before using alternating air pressure mattress / cushion systems ensure that: the electricity supply is of the type indicated on the power unit the mains lead is free from damage and is positioned so as not to cause an obstruction the system is not used in the presence of flammable anaesthetics For 110V units only - means to isolate the power unit from the electricity supply shall be carried out via disconnecting the plug attached to the non-detachable mains cord from the wall socket. The equipment conforms to IEC for electromagnetic interference, however should the equipment be subjected to electromagnetic interference outside this then the unit should be recalibrated by a qualified service technician. Do not place mattress/cushion or power unit on or near a heat source. Do not use with hot water bottles or electric blankets. Although the materials used in the manufacture of all components of the mattress/cushion system comply to the required fire safety regulations, Talley Medical advise against smoking whilst the system is in use, to prevent the accidental secondary ignition of associated items which may be flammable, such as bed linen. In order for alternating air pressure mattress/cushion systems to operate effectively, please avoid placing objects on the surface that may obstruct the movement of air between the cells. For the same reason, please discourage people from sitting on the edge or on the end of the mattress whilst it is in use. Do not place heavy objects on the surface of foam mattresses when not in use. Do not allow sharp objects to penetrate the cover material. Do not store in damp conditions. The system is used as part of a pressure ulcer prevention programme, not solely relied upon for this purpose. Alternating pressure therapy should not be used for patients with unstable fractures, gross oedema, burns or an intolerance to motion. It should be noted that the use of a cushion will increase the patient's seated height by approximately 5cm, and care should be taken to ensure the patient's comfort and security regarding height of foot and arm rests. 2
4 Alternating Air Pressure Mattresses & Cushions Installation and User Guidelines INSTALLING MATTRESSES 1. If using a mattress replacement system, which is intended to completely replace the bed mattress, remove any existing mattress from the bed frame. If using a mattress overlay system, ensure bed frame to be used has an existing mattress in place. 2. Place the mattress on the bed frame/existing bed mattress. If using a powered mattress ensure the mattress hose exits at the foot end on the right hand side and the coloured cover is uppermost. 3. Secure the mattress to the bed frame/existing mattress using adjustable straps - pass straps beneath or around bed frame mattress platform/ bed mattress and secure with the buckles (Fig. 1), allowing for moving components on electric bed frames. This is important as it stops the mattress becoming detached from the bed frame/existing bed mattress and causing possible injury to the patient. 4. Suspend the power unit from the foot board of the bed having first adjusted the hanger brackets as instructed at the rear of the unit. Alternatively the power unit may be placed on the floor. Fig. 2 Fig Attach the air supply hose to the power unit by aligning the black line on the air supply hose connector with the black line on the power unit connector and pushing together. Rotate the mattress hose connector clockwise until the green indicator fills the indicator hole on the power unit connector (Fig. 2). 6. Plug the smaller end of the power lead into the left hand side of the power unit, and the other end into mains outlet in wall. Ensure that the mains lead and tubing cannot become trapped in the bed frame. 7. Switch the power on at the outlet, and at the side of power unit adjacent to the power lead entry. 8. The system will display STARTING, then INITIALISING whilst the mattress inflates (this will take between minutes). 3
5 Note: It is important that during the INITIALISING phase the mattress connector is not disconnected from the power unit. If this is done, the power unit must be switched off, MUTE button pressed when the audible alarm is made, the mattress connector re-engaged, and the power unit restarted. If UNCALIBRATED is displayed when switched on, the system will continue to operate but should be recalibrated as soon as possible. 9. When a bottom sheet is added to the mattress, ensure that it is left loose to allow the mattress surface to conform with the patient's body as much as possible. 10. Allow the mattress to inflate before positioning the patient on the mattress. 11. Once inflated the system will automatically default to medium comfort setting (3). The comfort setting and the associated patient weight range guidelines are shown on the display screen. The comfort setting can be adjusted using the up and down arrow buttons (see COMFORT CONTROL on page 5). 12. Place the carry bag and user manual in a safe place for future use. INSTALLING CUSHIONS The QUATTRO PLUS, QUATTRO OVERLAY AND PULSAIR CHOICE power units can all be used to operate their respective alternating air pressure cushions. Place the cushion on a chair, ensuring that it is placed the correct way up with the BACK labelling (if applicable) facing the back of the chair. Secure cushion to chair using adjustable straps, where available. 1. The PULSAIR CHOICE cushion is connected to the PULSAIR CHOICE power unit exactly as described in points 5. to 9. above and will take approx. 30 seconds to inflate. 2. The B.A.S.E. SEQUENTIAL and B.A.S.E. RECLINER MAT cushions can be used with the QUATTRO PLUS and QUATTRO OVERLAY mattress systems, either operated with the mattress or, using a cushion adaptor, directly with the power unit, as follows:- a) To use the cushion directly with the power unit, connect the cushion adaptor to the power unit, rotating the adaptor clockwise until the green indicator fills the indicator hole on the power unit connector. Connect the air supply hose from the cushion onto the adaptor, matching up the alignment markings (Fig. 3). Ensure that this has been correctly clicked into place, otherwise Fig. 3 a leak may occur. Attach the power lead, plug into the mains outlet and switch the power on at the side of power unit adjacent to the power lead entry. Once inflated (approx. 5 minutes) increase the comfort control setting to maximum (6). 4
6 NB. If using the power unit from an operating Fig. 4 mattress system, first press the MAX. INFLATE button (if applicable) to fully inflate the mattress, then rotate the air supply hose connector anticlockwise and detach from the power unit to seal the air within the mattress to leave it fully inflated. To reconnect the mattress to the power unit after using the cushion, switch off the power unit and disconnect the cushion adaptor. Re-connect the mattress air supply tubing to the power unit, and switch on the power unit [operation will automatically default to medium comfort setting (3)]. b) To use the cushion whilst the mattress is operating, simply attach the air supply hose from the cushion to the connection port on the side of the head end of the mattress by matching up the alignment markings and pushing together the CPC connectors until they click into place (Fig. 4), increasing the comfort control setting to maximum (6). The mattress and cushion will operate simultaneously, allowing the simple transfer of the patient between the bed and chair. N.B. It should be noted that the use of an alternating air pressure cushion will increase the patient s seated height by approximately 5cm, and care should be taken to ensure the patient s comfort and security regarding height of foot and arm rests. OPERATION BUTTONS The operation buttons on the face of the power unit provide the following functions. Please refer to your individual model to find those relevant to your mattress system. THERAPY MODE Pressing the THERAPY MODE button will toggle between ACTIVE (1 in 4 alternating air pressure cycle) and STATIC (for continuous low pressure therapy) modes. The selected therapy mode is shown on the display screen. The default mode is ACTIVE therapy. To switch to STATIC MODE, press THERAPY MODE button for 2 seconds until an audible tone is heard. The system will then display 'PLEASE WAIT' and requires approximately 2 minutes to initialise. COMFORT CONTROL Air pressure is regulated within each of the cells throughout the cycle so that support, posture and therapy are constantly maintained at optimum levels, irrespective of patient weight, movement or position. Equalisation of cell pressure automatically takes place at each stage of the 1-in-4 cycle, again to ensure precise pressure and therapy is provided. The automatic default comfort setting is level 3. However, if the patient prefers a firmer or softer mattress, increase or decrease the comfort control setting 5
7 accordingly using the up and down arrow buttons (soft: 1 - firm: 6). The comfort setting and the associated patient weight range guidelines are shown on the display screen. Check periodically to ensure patient support and comfort. DATA Pressing the DATA button at any time switches the display into DATA mode. Use the up and down arrow buttons to scroll through the product data and user information set. Pressing the DATA button again returns the display to the previous mode. NB. Used for accessing information only, does not affect mode of operation. MUTE* Press to silence alarm and to clear alarm display from display screen. MUTE/LOCK* Press to silence the alarm and to clear the alarm display from the display screen. The power unit will automatically lock 2 minutes after the last button operation when running to prevent the inadvertent operation of button functions (except MUTE), as indicated by 'L' on the display screen. Press and hold the MUTE/UNLOCK button until the power unit beeps if further button operation is needed (i.e. comfort setting). The power unit will lock again 2 minutes after the last button operation. *NB. After power failure/switching the power off, pressing MUTE cancels the system's previous settings. When power returns the default setting of ACTIVE mode, comfort setting 3 is invoked. (Note that previous settings are automatically cancelled if the duration between switch off and switch on is greater than 12 seconds. If power returns before a period of 12 seconds has passed and the MUTE button has not been pressed, the system will return to the previous mode of operation.) MAX. INFLATE Necessary for some nursing procedures, the MAX INFLATE mode inflates the mattress to maximum static pressure (50mmHg) for a period of 15 minutes. After pressing the MAX INFLATE button to inflate mattress, the system displays 'PLEASE WAIT' followed by 'READY' and a 5 second audible tone when maximum pressure is achieved and 'MAX INFLATE' is shown on the display screen. After 15 minutes the system automatically returns to the active mode of operation. USER WEIGHT GUIDELINES QUATTRO ACUTE and QUATTRO PRIME:- no min. weight / 250kg (39 stone) max. QUATTRO PLUS and PULSAIR CHOICE mattress replacement:- no min. weight / 200kg (31 stone) max. QUATTRO OVERLAY:- 26kg (4 stone) min / 160kg (25 stone) max. PULSAIR CHOICE mattress overlay:- 26kg (4 stone) min / 127kg (20 stone) max. B.A.S.E. SEQUENTIAL and B.A.S.E. RECLINER MAT cushions:- no min. weight / 127kg (20 stone) max. PULSAIR CHOICE cushion:- 26kg (4 stone) min / 102kg (16 stone) max. 6
8 CPR FACILITY (Fig. 5) - ALL ALTERNATING AIR PRESSURE MATTRESSES EXCEPT QUATTRO PRIME The CPR device is situated at the head end on the right hand side of the mattress (viewed from foot end), as indicated by arrows on the mattress tag. For rapid deflation rotate the dial of the CPR device anti-clockwise to click into the open position. If reinflating the mattress, make sure the dial of the CPR device is rotated clockwise until clicked into the closed position. PATIENT TRANSPORT FACILITY (Fig. 6) - ALL ALTERNATING AIR PRESSURE MATTRESSES EXCEPT QUATTRO PRIME Press MAX. INFLATE button (if applicable) to fully inflate the mattress. When maximum pressure is achieved, detach the mattress air supply hose from the power unit by rotating the mattress hose connector anticlockwise until the black lines align, and pull the mattress hose connector away. The mattress will remain inflated, so supporting the patient. Fig. 5 Fig. 6 All alternating air pressure mattresses can be used on profiling bed frames, slatted frames, in-filled frames and divans. Back rests or pillows for support should be placed beneath the mattress to allow uninterrupted body contact with the mattress surface. Place the bottom sheet loosely on the mattress to allow the mattress surface greater contact with the patient s body. Avoid using fitted sheets. The use of incontinence sheets / excessive bedding beneath the patient may reduce the pressure relieving effect of the mattress. To remove air from the mattress when dismantling the system, use the CPR facility as described above (all mattresses except QUATTRO PRIME - to remove air from the QUATTRO PRIME detach mattress air supply hose from power unit by rotating mattress hose connector anti-clockwise until black lines align, and pull mattress hose connector away). Care should be taken when raising and lowering bed safety side rails in order to avoid possible interference with the CPR and cushion connection port where fitted. A gap of 2.5cm on either side of the mattress should not be exceeded when side rails are deployed. 7
9 Care and Maintenance COVER Always keep the mattress/cushion cover as clean as is practicable. The material is waterproof and vapour permeable. Inspect top cover for signs of damage or wear which could result in the contamination of the interior, e.g. tears, holes, damage to seams or zips, underside staining, etc. The frequency of these checks should be at each decontamination process, i.e. between patients or patient occupancy (or weekly for longer term patients) Care should be taken to avoid puncturing cover with objects such as needles, scalpels, pat slides, acrylic nails, etc. The cover may be removed and cleaned in accordance with The Revised Healthcare Cleaning Manual June 2009 subject to the following action: Following the use of a detergent and or disinfectant solution the mattress cover should be rinsed with clean water using a clean cloth and allowed to dry. Frequent or prolonged exposure to high concentration disinfectant solution may reduce the useful life of the mattress/cushion cover. Where high concentration disinfectants e.g. 10,000ppm chlorine releasing agent (CRA) or combined chlorine releasing agent (CRA) and detergent solutions are used to clean and disinfect blood or other body fluids, mattresses/cushions should be rinsed with clean water using a clean cloth. This will help prevent any possible long term compatibility issues associated with disinfectant residues. Alternatively disinfection may be achieved by laundering at temperatures not exceeding 65 0 C for 10 minutes or 73 0 C for 3 minutes which may include a chlorine rinse. Do not use abrasive cleaners, solvents or alcohol-based cleansers, e.g. Phenicol, Hibiscrub, Clearsol, Stericol, Hycoline as these will destroy the cover materials. Do not iron. Ensure that the mattress/cushion is thoroughly dried before remaking the bed or placing in storage. INTERIOR COMPONENTS Check air cells and mattress/cushion interior for signs of damage or contamination, e.g. staining or evidence of fluid ingress. The frequency of these checks should be at each decontamination process, i.e. between patients or patient occupancy (or weekly for longer term patients) Care should be taken to avoid puncturing air cells with objects such as needles, scalpels, pat slides, acrylic nails, etc. The individual cells can also be wiped clean with a mild antiseptic solution. All cells are replaceable and can be obtained easily from Talley Medical. Do not immerse the PULSAIR CHOICE mattresses/cushion in water. The QUATTRO range of mattresses are fully launderable, but ensure the CPR device is fully closed (i.e. the dial of the CPR device is rotated clockwise until clicked into the closed position ), prior to laundering to prevent water entering the air cells / tubing. 8
10 POWER UNIT Always disconnect the power unit from the electricity supply before cleaning. Power units can be wiped down with a detergent or disinfectant solution or wipe. Do not use solvents. The unit contains no user serviceable parts, and should only be serviced by a competent electrical engineer, or returned to Talley Medical / your local authorised dealer. All Talley Medical products should be serviced every two years by Talley Medical or authorised dealer in order to comply with warranty conditions. It is the customer s responsibility to ensure the following prior to collection: the system is cleaned of any obvious contaminants. contamination status is documented. assistance is given to Talley Medical personnel to bag the equipment if the mattress has been in a known or suspected infectious environment. SYSTEM DESIGN LIFE: 5 years HANDLING AND STORAGE Handle with care. Please report instances of damage or impact to Talley Service Department. Temperature: Operational: 10 o C to 40 o C Storage: 10 o C to 55 o C Humidity and other environmental conditions: refer to the Service Manual. TRANSPORTATION OF MATTRESS SYSTEM The mattress should be loosely rolled lengthwise with the cover innermost, taking care not to strain the umbilical. It can then be transported and stored in the carry bag with the power unit, mains cable and this booklet. Do not stack bagged mattresses more than two high to avoid strain on the umbilical. Fault Finding All alarms can be reset by pressing the MUTE button once. This also cancels the fault displays. MUTE also silences the audible alarm. All systems have a fault log that records the last 5 faults via the DATA display mode. If problems reoccur contact Talley Medical. AC FAIL fault indicates a mains power failure, an audible alarm will sound if power is interrupted, e.g. power unit switched off, power cut, disconnection of mains lead. Press MUTE or re-connect to power supply. ROTOR SYSTEM fault indicates the automatic sequential cycle has stopped or there is a fault in the system. Switch power off, press MUTE button, then switch power on again. If the fault re-occurs, contact Talley Medical. 9
11 LOW PRESSURE warning will alert if pressure falls below the minimum allowable levels. Check that the hose is connected to the power unit correctly. Check that the CPR device is fully closed, i.e. the dial of the CPR device is rotated clockwise until clicked into closed position. Check that the internal cells are connected and that no cell is punctured. Press the MUTE button to clear alarm. Note that the alarm will reoccur if the fault persists, if the fault re-occurs, contact Talley Medical. EMI fault indicates that the unit detects the pressure sensor amplifier is adversely affected by external RF fields. This will clear when interference ceases. OTHER ALARMS PUMP OR TRIAC fault - indicates a pump control failure or an open pump coil fault. Should this occur, contact Talley Medical. UNCALIBRATED - contact Talley Medical for recalibration. If you have any queries relating to this system please contact Talley Medical or your local authorised dealer. 10
12 Static Foam Mattresses Installation and User Guidelines MATTRESSES 1. Ensure the bed frame to be used has no existing mattress components, and is free from items which could cause damage to the SUPREMA / DORMIRA mattress. It should be noted that this mattress is intended to completely replace the existing mattresses. 2. Place the SUPREMA / DORMIRA mattress on the bed frame. NB. If using the SUPREMA mattress ensure that the mattress is positioned with the printed cover uppermost with the grey, non-slip base facing downwards. 3. Place the user manual in a safe place for future use. The SUPREMA / DORMIRA mattress can be used on profiling bed frames, slatted frames, in-filled frames and divans. A gap of 2.5cm either side of the mattress should not be exceeded when side rails are deployed. CUSHIONS Place the SUPREMA / DORMIRA cushion onto a chair. If using the SUPREMA cushion ensure that it is positioned with the green cover uppermost with the grey, non-slip base facing downwards. N.B. It should be noted that the use of a foam cushion will increase the patient s seated height by approximately 5cm, and care should be taken to ensure the patient s comfort and security regarding height of foot and arm rests. Care and Maintenance The SUPREMA / DORMIRA mattress/cushion will provide years of efficient service if it is cared for in the following way: COVER Always keep the mattress/cushion cover as clean as is practicable. The material is waterproof and vapour permeable. 11
13 Inspect top cover for signs of damage or wear which could result in the contamination of the interior, e.g. tears, holes, damage to seams or zips, underside staining, etc. The frequency of these checks should be between patients or patient occupancy (weekly for longer term patients) Care should be taken to avoid puncturing cover with objects such as needles, scalpels, pat slides, acrylic nails, etc. The cover may be removed and cleaned in accordance with The Revised Healthcare Cleaning Manual June 2009 subject to the following action: Following the use of a detergent and or disinfectant solution the mattress cover should be rinsed with clean water using a clean cloth and allowed to dry. Frequent or prolonged exposure to high concentration disinfectant solution may reduce the useful life of the mattress/cushion cover. Where high concentration disinfectants e.g. 10,000ppm chlorine releasing agent (CRA) or combined chlorine releasing agent (CRA) and detergent solutions are used to clean and disinfect blood or other body fluids, mattresses/cushions should be rinsed with clean water using a clean cloth. This will help prevent any possible long term compatibility issues associated with disinfectant residues. Alternatively disinfection may be achieved by laundering at temperatures not exceeding 65 0 C for 10 minutes or 73 0 C for 3 minutes which may include a chlorine rinse. Do not use abrasive cleaners, solvents or alcohol-based cleansers, e.g. Phenicol, Hibiscrub, Clearsol, Stericol, Hycoline as these will destroy the cover materials. Do not iron. Ensure that the mattress/cushion is thoroughly dried before remaking the bed or placing in storage. INTERIOR Inspect the mattress/cushion interior for signs of damage or contamination, e.g. staining or evidence of fluid ingress. The frequency of these checks should be at each decontamination process, i.e. between patients or patient occupancy (or weekly for longer term patients) Contaminated mattresses/cushions should be removed from service and disposed of in accordance with local policy. Regular turning will prolong the life of the mattress. The SUPREMA has a 2 way turning cycle and the DORMIRA has a 4 way turning cycle. Please refer to instructions printed on cover. SYSTEM DESIGN LIFE: 3 years HANDLING AND STORAGE Handle with care. Please report instances of damage or impact to Talley Service Department. The mattress should be stored flat. Temperature: Operational: 10 0 C to 40 0 C Storage: 10 0 C to 55 0 C 12
14 TRANSPORTATION OF MATTRESS SYSTEM The mattress should be transported flat and not rolled. Mattresses should not be stored more than 6 high as this can potentially be a safety hazard when handling. To protect the covers, mattresses should be packed in minimum 200 micron clear polythene. Specifications ALTERNATING AIR PRESSURE POWER UNITS Construction: ABS Plastic Dimensions: 335mm/13.2 x 233mm/9.2 x 165mm/6.5 Weight: 3.4 kg / 7.5 lbs Mains Cable: 5 metres / 16.5 Electricity Supply: 240V ~ 50Hz USA:- 110V ~ 60Hz Saudi Arabia: 240V ~ 60Hz Full Load Wattage: 12W Fuse Rating: 2 x 500mA Cycle Time: QUATTRO ACUTE: variable (continuous) QUATTRO PRIME: variable (continuous) QUATTRO PLUS: 15 minutes (continuous) QUATTRO OVERLAY: 15 minutes (continuous) PULSAIR CHOICE: 15 minutes (mattress replacement) / 10 minutes (mattress overlay/cushion) (continuous) 13 ALTERNATING AIR PRESSURE MATTRESSES Construction: BASE: QUATTRO ACUTE / QUATTRO PRIME / QUATTRO PLUS / QUATTRO OVERLAY: Woven nylon 940 DTEX PU coated both sides PULSAIR CHOICE: PVC coated 2oz nylon, 350 micron CELLS: PU film COVER: PU coated stretch nylon 255g/m 2 Options: Standard / Long / Narrow Type: QUATTRO ACUTE / QUATTRO PRIME / QUATTRO PLUS / PULSAIR CHOICE MATTRESS REPLACEMENT: Orthodifferential pleated air cells operating in a 1-in-4 alternating air pressure cycle QUATTRO OVERLAY: Orthodifferential air cells operating in a 1-in-4 alternating air pressure cycle PULSAIR CHOICE mattress overlay: One piece air cell set operating in a 1-in-2 alternating air pressure cycle Dimensions QUATTRO ACUTE/QUATTRO PRIME: 1980mm x 880mm x 240mm (UK standard size) QUATTRO PLUS/PULSAIR CHOICE MATTRESS REPLACEMENT: 1950mm x 880mm x 180mm QUATTRO OVERLAY: 1930mm x 855mm x 130mm
15 PULSAIR CHOICE MATTRESS OVERLAY: 2000mm x 840mm x 128mm Weight: QUATTRO ACUTE: 12.5kg; QUATTRO PRIME: 10.6kg QUATTRO PLUS: 9.4kg QUATTRO OVERLAY: 6.3 kg PULSAIR CHOICE: 8.0kg (mattress replacement) / 5.5kg (mattress overlay) ALTERNATING AIR PRESSURE CUSHIONS Construction: BASE: B.A.S.E. SEQUENTIAL / RECLINER MAT cushion: Woven nylon 940 DTEX PU coated both sides PULSAIR CHOICE cushion: PVC coated 2oz nylon, 350 micron INNER: B.A.S.E. SEQUENTIAL / RECLINER MAT cushion: PVC bellows within punched CMFR foam PULSAIR CHOICE cushion: PU film COVER: PU coated stretch nylon 255g/m 2 Type: B.A.S.E. SEQUENTIAL / RECLINER MAT cushion: 8/20 rows of 6 bellow cell strips operating in a 1-in-4 alternating air pressure cycle PULSAIR CHOICE cushion: One piece air cell set operating in a 1-in-2 alternating air pressure cycle Dimensions B.A.S.E. SEQUENTIAL cushion: 430mm x 430mm x 70mm (UK standard size) B.A.S.E. RECLINER MAT cushion: 1080mm x 430mm x 70mm PULSAIR CHOICE cushion: 430mm x 430mm x 40mm Weight: B.A.S.E. SEQUENTIAL cushion: 1.9kg; B.A.S.E. RECLINER MAT cushion: 3.9kg PULSAIR CHOICE cushion: 1.3kg STATIC FOAM MATTRESSES & CUSHIONS Construction: SUPREMA mattress/cushion: 57-63kg/m 3 density viso-elastic foam over a base of kg/m 3 nominal density / N nominal hardness SAFEGUARD CMHR DORMIRA mattress/cushion: Multi-layered SAFEGUARD CMHR foam: kg/m 3 nominal density / N / N nominal hardness Cover: PU coated stretch nylon 255g/m 2 Dimensions SUPREMA mattress: 1970mm x 880mm x 160mm SUPREMA cushion: 432mm x 432mm x 76mm DORMIRA mattress: 1970mm x 880mm x 127mm DORMIRA cushion: 432mm x 432mm x 76mm Weight: SUPREMA mattress/cushion: 13.5kg / 1.0kg DORMIRA mattress/cushion: 10.0kg / 0.9kg Turning cycle: SUPREMA mattress/cushion: 2 way DORMIRA mattress/cushion: 4 way MANUFACTURER'S GUARANTEE All power units, alternating mattresses/cushions and foam mattresses/cushions are covered by a 24 month manufacturer's guarantee. 14
16 EXPLANATION OF LABEL SYMBOLS AND STATEMENTS ATTENTION Consult accompanying documents Medical Devices Directive 93/42/EEC Electrical Protection Type B Class II Equipment (Double Insulated) Do not dispose of with the normal household waste (please refer to for further details) WARNING CAUTION This is a statement that alerts the user to the possibility of serious injury or other adverse reactions with the use or misuse of the device This is a statement that alerts the user to the possibility of a problem with the system associated with its use or misuse This product is CLASSIFIED by Underwriters Laboratories Inc. with respect to electric shock, fire and mechanical hazards only in accordance with UL and CAN/CSA-C22.2 No USER MANUAL PART NUMBER TALLEY GROUP LIMITED Premier Way, Abbey Park Industrial Estate, Romsey, Hampshire SO51 9DQ England Web: Europe re-order:- (0) USA re-order:- Talley USA /2011
Operation Manual FOR 14029 & 14030
Operation Manual FOR 14029 & 14030 IMPORTANT SAFEGUARDS When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following:
Active Pressure Relieving Systems
Active Pressure Relieving Systems Phase III The easy access, simple to use CPR facility tag allows rapid deflation of the mattress within 10 seconds. The Phase III mattress incorporates high frequency
PROdUcT specifications Pump Mattress Replacement ALPHA REsPONsE PREssURE REdIsTRIbUTION system Mattress Overlay seat cushion GETINGE GROUP
ALPHA RESPONSE Pressure Redistribution System with people in mind INTRODUCTION For over 20 years the Alpha range of pressure redistributing mattresses has been proven to offer patients, carers and healthcare
Dual Cushion User Manual. Specialist Suppliers to the Healthcare Industry
Dual Cushion User Manual Specialist Suppliers to the Healthcare Industry Thank you for purchasing this Shelden Healthcare pressure relieving cushion system. PLEASE READ THIS USER MANUAL CAREFULLY BEFORE
RESTWELL RISE & RECLINE ARMCHAIRS BORG - OWNER S HANDBOOK PARTS DESCRIPTION
RESTWELL RISE & RECLINE ARMCHAIRS BORG - OWNER S HANDBOOK CONTENTS 1. Introduction 2. Model Description 3. Parts Description 4. Personal Safety 5. Installation Instructions 6. Backrest Removal 7. Operating
San josé OWNER S MANUAL
San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.
BeoLab 11 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
Med-Aire 8 Alternating Pressure Mattress Replacement System With Low Air Loss
Med-Aire 8 Alternating Pressure Mattress Replacement System With Low Air Loss OPERATOR S MANUAL Item # 14027 www.drivemedical.com TABLE OF CONTENTS IMPORTANT SAFEGUARDS... 3 STATEMENTS & SYMBOLS...4 INTRODUCTION...5
NFC Communication Tray Model: HHX-IT3-Z
INSTRUCTION MANUAL NFC Communication Tray Model: HHX-IT3-Z ENGLISH CONTENTS Introduction...3 Important safety information...4 Know your unit...6 Transferring data to the PC...7 Care and maintenance...8
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
3 WATT LED SPOTLIGHT Model No. SLM - 3801
3 WATT LED SPOTLIGHT Model No. SLM - 3801 OWNER'S MANUAL Customer Service Tel: 1-800-268-3319 Superex Canada Ltd, Toronto,M2H 3B8 Made in China Table of Contents A). Important Safety Instructions B). Charging
Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!
BeoLab 6002 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects
orlando OWNER S MANUAL
orlando OWNER S MANUAL 2 Assembling & operating manual Orlando 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
- 2 - IMPORTANT SAFETY REMINDERS
USER MANUAL IMPORTANT SAFETY REMINDERS This appliance should only be used for domestic cleaning, as described in this user guide. Please ensure that this guide is fully understood before operating the
neptune aquila serena solo Operating Instructions bath lift bath lift pillow lift mountway toilet lift bringing independence to life
serena Operating Instructions bringing independence to life Operating instructions and parts list Please read the following instructions carefully before using your Neptune Bath Lift This is designed and
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL
Electric Kettle Model: SK-1717 INSTRUCTIONS MANUAL Thank you for your purchase. Please read this Instruction Manual thoroughly before use and keep in a safe place for future reference. READ ALL INSTRUCTIONS
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Operations Manual Blast Chiller
Operations Manual Blast Chiller ADE- 2039-A Page 1 of 14 Contents Page 1 What is the Adande System 3 2 Adande Technology Explained 3 3 EC Declaration of Conformity 4 4 Storage of Product 5 5 Operating
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
Heated throw User manual
Heated throw User manual OVELTHROWBB & OVELTHROWGB CONTENTS Safety & Warnings... 3 Product features.... 5 Controller... 5 Quick start guide.... 6 Using your heated throw.... 7 Before First Use... 7 Turning
ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN
BeoLab 7-6 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
OPERATING INSTRUCTIONS AQUAJOY PREMIER PLUS AND AQUAJOY JUNIOR PLUS
OPERATING INSTRUCTIONS AQUAJOY PREMIER PLUS AND AQUAJOY JUNIOR PLUS First point of contact is always as follows unless supplied by a Local Authority or Dealer. AQUAJOY BATHLIFTS LTD CONSETT BUSINESS PARK
DMSG_0152_0112_V4 Mamas & Papas (Holdings) Ltd. 2012 Dream Swing - 1 -
DMSG_0152_0112_V4 Mamas & Papas (Holdings) Ltd. 2012 Dream Swing - 1 - DREAM SWING THESE INSTRUCTIONS ARE IMPORTANT. PLEASE READ CAREFULLY AND RETAIN FOR FUTURE REFERENCE. Read the entire instruction before
2 (. 3 4 5 . -,.. -,. 3. : 1 2 3 > 4, :!! 1,, 17 Lt MAX 2 3 4,, > 5.,,, 6 :, :1)! 2)! 7,, 1, :,. 2,, Bottom of steam generator 7 8 9 10 11 12 automatically and this phenomenon will continue for
Instruction manual for Firstline FCS12000CH
Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
Digital Photo Picture Frame. Operation Manual
Digital Photo Picture Frame Operation Manual 20070309 CONGRATULATIONS on your purchase of a Polaroid 7 LCD Digital Photo Picture Frame. Please read carefully and follow all warnings and instructions in
VersaCare Bed. Quick Reference Guide
VersaCare Bed Quick Reference Guide Bed Features Item Description Page A Emergency CPR and Emergency 3 Trendelenburg a Control B Battery Back-Up 4 C Foot Controls 4 D Point-of-Care Caregiver Control Panel
W850. Maintenance Guide
W850 Maintenance Guide August 2011 www.lexmark.com Contents...3 Cleaning the exterior of the printer...3 Storing supplies...3 Conserving supplies...3 Checking the status of supplies...4 Checking the status
MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W
MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W Safety Precautions To reduce the risk of personal injury or damage to property, basic safety precautions must be observed including the
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions
SBC90 Abrasive Blast Cabinet Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. This manual provides important
IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions
Luna/200. Luna/275. Ceiling hoist. User instruction. Important - warning. This manual must be read before the Luna is used
Luna/200 Luna/275 Ceiling hoist User instruction! Important - warning This manual must be read before the Luna is used This manual is intended for technicians, installers, therapists and other personnel,
Record Cleaning Machine
Record Cleaning Machine Owner s Manual UK December 2010 Photo 1 Photo 2 IMPORTANT! READ THIS OWNER S MANUAL CAREFULLY, BEFORE USING THE MACHINE! Introduction You are now the proud owner of an Okki Nokki
Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance
Bench Autoclave Standard Operating Procedure For Installation, Use and Maintenance 1. Introduction This SOP is intended for use with the following model, in a laboratory context: Type: Nuve Bench Top Steam
Anti-decubitus Mattress 418E 516E - 820Z User's manual
Anti-decubitus Mattress 418E 516E - 820Z User's manual Manufacturer: MOBILEX A/S Denmark Rev. 03/15 Page 1 of 7 UM-270001-12-GB 1. General information Dear customer, This user manual contains a description
FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK
FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK If you have any questions about the operation of your fireplace heater, please contact Crane Customer Care. Toll Free: 888-599-0992
Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590. Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580
Any Queries Call : 08000 23 23 23 Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590 Rapide Inline Ceiling Extractor Fan, White Fascia Illuminated 41800040670 Rapide Inline Ceiling Extractor
pc-6 humantouch.com use & care manual 800.355.2762
pc-6 800.355.2762 2009 Human Touch, LLC. Patents pending and intellectual property rights enforced. No medical claims are warranted or implied by the use of this product. Human Touch is a trademark of
NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.
CAUTION: General Safety Instructions Use the following safety guidelines to help ensure your own personal safety and to help protect your equipment and working environment from potential damage. NOTE:
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL Congratulations on choosing the Fascination 700 HVLP Tanning Pro System! Your system includes the following items: 1 Fascination 700 HVLP Tanning Pro
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
4.3-inch Back-Up Camera
TM 4.-inch Back-Up Camera Model No.: PKC0BU4 Owner s Manual and Warranty Information Read these instructions completely before using this product. Retain this Owner s Manual for future reference. INTRODUCTION
MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference
MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725 Read this manual thoroughly before using and save it for future reference Purchase MAP capsules at Harvey Norman stores nationwide
Jarv Joggerz BT-301 Bluetooth Stereo Headphones Users Guide
Jarv Joggerz BT-301 Bluetooth Stereo Headphones Users Guide Features: Bluetooth Wireless technology Compact design fits in the palm of your hand and weighs less than 2 oz. Comfortable Behind the Neck design
Table of Contents TO OPERATE THE 12.0 VOLT POWER PACK: THIS OPERATES ONLY OFF THE UNIT S RECHARGEABLE BATTERY, NOT OFF YOUR VEHICLE S BATTERY.
TO OPERATE THE 12.0 VOLT POWER PACK: THIS OPERATES ONLY OFF THE UNIT S RECHARGEABLE BATTERY, NOT OFF YOUR VEHICLE S BATTERY. Table of Contents Page No. 1. Turn the main power switch located on the back-side
EP2242393; WO2012/080751; GB1210274.5
Curl Secret 2667U UK Patent and Application Nos. GB2455716; EP2242393; WO2012/080751; GB1210274.5 BaByliss CURL Secret The BaByliss Curl Secret has revolutionary technology to effortlessly create beautiful,
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:
NIMBUS range advanced MattreSS
NIMBUS range advanced MattreSS replacement SySteMS with people in mind OPTIMUM PRESSURE RELIEF AND COMFORT In clinical use for more than 20 years, Nimbus alternating Mattress replacement Systems have consistently
Installation Instructions
Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. Esenboğa Yolu 22 km Akyurt - ANKARA / TURKEY Tel : (00 90 312)
PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!
PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE! 1. Read all instructions carefully before using the machine. 2. Do not touch hot surfaces. Use handles or knobs. The lid and
15GAL STEEL OIL DRAIN WITH 110V PUMP
15GAL STEEL OIL DRAIN WITH 110V PUMP OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
Model 349KLX Remote Display Digital Scale User Instructions
Model 349KLX Remote Display Digital Scale User Instructions P/N UM349KLX Rev 3-080713 1 Model 349KLX Thank you for your purchase of this Health o meter Professional product. Please read this manual carefully,
Please read and keep these instructions. Run water through your machine before first use
47070 Rev 1 24/3/05 2:23 PM Page 1 12 cup filter coffee maker Please read and keep these instructions getting the best from your new coffee maker Safety first Caution must be used when handling hot water,
AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. White series
C88-VW-B UG [Update 10.05.12]_User guide 10/05/2012 09:40 Page 1 User Guide Vax Careline: (UK) 0844 412 8455 Bagless Cylinder White Get Cleaning... What s your Vax model number? (Located on the top flap
Bed Cleaning Procedure
This is an official Northern Trust policy and should not be edited in any way Bed Cleaning Procedure Reference Number: NHSCT/10/308 Target audience: Nursing and Midwifery Staff Sources of advice in relation
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
2-SLICE COOL TOUCH TOASTER
2-SLICE COOL TOUCH TOASTER PLA0405 Instruction Manual Due to on-going product improvements, specifications and accessories may change without notice. Actual product may differ slightly to that depicted.
Get Cleaning... User Guide Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. Multifunction. vax.co.uk. 6131 Series. What s your Vax model number?
6131 Series User Guide v1.1-06.09.10:user guide 09/09/2010 11:42 Page 1 User Guide Vax Careline: (UK) 0844 412 8455 Multifunction Get Cleaning... What s your Vax model number? 6 1 3 1 What s your serial
VACUUM CLEANER INSTRUCTION MANUAL
VACUUM CLEANER INSTRUCTION MANUAL MODEL: SVC9702 PLEASE READ THIS MANUAL CAREFULLY BEFORE USING AND KEEP IT PROPERLY FOR FUTURE USE 1 Safety Cautions: WARNING: To reduce the risk of fire, electrical shock,
Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase
User s Guide Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase of the FLAVORCHEF cooking system, which will provide you with healthy and tasty meals for
Nokia Bluetooth Headset BH-607. Issue 2. 1
Nokia Bluetooth Headset BH-607 2 3 1 4 5 6 7 8 9 11 10 Issue 2. 1 12 13 14 DECLARATION OF CONFORMITY Hereby, NOKIA CORPORATION declares that this BH-607 product is in compliance with the essential requirements
PRODUCT INTENDED USE:
PRODUCT INTENDED USE: The mattress overlays are intended for use with existing mattresses; they are not intended to replace existing mattresses. ROHO DRY FLOATATION Mattress Overlay and ROHO DRY FLOATATION
INSTALLATION & USER INSTRUCTIONS
INSTALLATION & USER INSTRUCTIONS LED ELECTRIC FIRE Focal Point Fires plc. Christchurch, Dorset BH23 2BT Tel: 0202 499330 Fax: 0202 499326 www.focalpointfires.co.uk e : [email protected] MODELS
Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS
+ Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,
Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada 1-888-845-7330
All about the Use & Care of your Iron Important Safeguards... 2 Iron Safety Instructions... 3 Parts and Features...4 TA B L E O F C O N T E N T S Using Your Iron...6 Cleaning and Maintenance... 8 Warranty...9
OPERATING MANUAL ASSEMBLY. Remote control docks magnetically. click. until it clicks and locks. REGISTER YOUR FREE 2 YEAR GUARANTEE TODAY
OPERATING MANUAL ASSEMBLY Remote control docks magnetically. 1 2 Align the black arrows. click Then twist clockwise until it clicks and locks. YOUR FREE 2 YEAR GUARANTEE TODAY Controls 1. Power on 2. Thermostat
BeoLab 1. User s guide
BeoLab 1 User s guide Legal notice: CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing
CAR SEAT/ STROLLER INSTRUCTION MANUAL
CAR SEAT/ STROLLER INSTRUCTION MANUAL English PM-0624AB 3/98 Do not use this 4-in-1 System until you read and understand these instructions! IMPORTANT INFORMATION Thank you for selecting this 4-in-1 System
Gemini II. Subwoofer System OWNERS MANUAL
Gemini II Subwoofer System OWNERS MANUAL CONTENTS Page No. 1) Safety instructions. 2) 3) 4) Connecting up your Gemini II. Connecting up using the high level input. Connecting up using the low level input.
Lexmark E260, E260d, and E260dn Series. Maintenance Guide
Lexmark E260, E260d, and E260dn Series Maintenance Guide May 2008 www.lexmark.com Contents...3 Cleaning the exterior of the printer...3 Storing supplies...3 Conserving supplies...3 Checking the status
Important Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
Peninsula Community Health. Safe Use of Mattresses, Pressure Relieving Cushions and Pillows
Peninsula Community Health Safe Use of Mattresses, Pressure Relieving Cushions and Pillows Title: Procedural Document Type: Reference: Safe Use of Mattresses, Pressure Relieving Cushions and Pillows Policy
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS This equipment has been tested and found to comply with the limits for a CLASS A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
System One Heated Humidifier USER MANUAL
System One Heated Humidifier USER MANUAL 2011 Koninklijke Philips Electronics N.V. All rights reserved. Table of Contents Intended Use... 2 Warnings... 2 Cautions... 2 Contraindications... 3 Symbol Key...
www.morphyrichards.co.uk
43922 rev2:x 06/01/2010 15:06 Page 1 Upon registration with Morphy Richards (UK & ROI only) Register online for your 2 year guarantee. See back of this instruction book for details. (UK and Ireland customers
Operating instructions in the back. www.blackanddecker.co.uk PD1020L
Operating instructions in the back www.blackanddecker.co.uk PD1020L 2 ENGLISH (Original instructions) Intended use Your Black & Decker Dustbuster handheld vacuum cleaner has been designed for vacuum cleaning
owner s manual EDGE 200 GPS-ENABLED CYCLING COMPUTER December 2012 190-01368-00_0B Printed in Taiwan
EDGE 200 GPS-ENABLED CYCLING COMPUTER owner s manual December 2012 190-01368-00_0B Printed in Taiwan Getting Started warning Always consult your physician before you begin or modify any exercise program.
How To Program An Autodialer
GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second
National- Spencer Inc.
9-27-2010 National- Spencer Inc. 19.2V HEAVY DUTY GREASE GUN PRODUCT SPECIFICATION Charger Input Power 110 VAC Battery Output Power 19.2V Battery Capacity 1500 MAH Battery Pack Charge Time 1 Hour Maximum
USER MANUAL. Advanta Bed. From Hill-Rom. Product No. P1600
USER MANUAL Advanta Bed From Hill-Rom Product No. P1600 2002 by Hill-Rom Services, Inc. ALL RIGHTS RESERVED. No part of this text shall be reproduced or transmitted in any form or by any means, electronic
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
PORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
User s manual FLIR VP50/VP52 Non-contact AC voltage detector
User s manual FLIR VP50/VP52 Non-contact AC voltage detector User s manual FLIR VP50/VP52 #T559851; r. AD/ 9134/9134; en-us Table of contents 1 Disclaimers... 1 1.1 Copyright... 1 1.2 Quality assurance...
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
Wine Cooler with Thermo-Electric Cooling & Heating Technology
Wine Cooler with Thermo-Electric Cooling & Heating Technology Model number: WC-0888H (8-bottles capacity) Instruction Manual Please read carefully and follow all safety rules and operating instructions.