1 RAID Software Suite for Linux Installation Guide Rev June 2000 Order Number:
2 Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined." Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The Intel Integrated RAID may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order. Copies of documents which have an ordering number and are referenced in this document, or other Intel literature may be obtained by calling or by visiting Intel's website at Copyright Intel Corporation, 2000 *Third-party brands and names are the property of their respective owners. RAID Software Suite for Linux Installation Guide Rev 1.001
3 Contents 1 RAID Software Suite Installation for Linux 1.1 Summary of Contents Software Requirements Install the RAID Software Suite onto an Existing Linux Server Installation Rebuild the Kernel with I 2 O Support Activate the I 2 O Subsystem RAID Software Overview RAID Configuration Services RAID Configuration Services Administration RAID Storage Console IRVIEW Using the RAID Software Suite Using RAID Configuration Services Administration Configure a RAID Volume in a Linux System Monitor the Status of the RAID Subsystem Uninstalling RAID Software Suite Booting to Red Hat Linux on an I 2 O RAID Volume Method 1 - MBR on Primary IDE Method 2 - MBR on I 2 O RAID Volume Technical Notes Linux Dynamic Block Device Limitations Miscellaneous Notes...21 Figures 1-1 Installation Confirmation Install the Kernel Sources Install Kernel Sources from Install Program Bypass Installation of Kernel Source Code Install Java Linux Kernal Configuration Configuring I 2 O Support in the Kernel Configuring I 2 O Support as Kernel Modules RAID Configuration Services Administration RAID Configuration Services Administration - Edit Configuration RAID Configuration Services Administration - User Management User Management Add User Screen User Management Change Password irview Screen...16 RAID Software Suite for Linux Installation Guide Rev
4
5 RAID Software Suite Installation for Linux Summary of Contents Install the RAID Software Suite onto an Existing Linux Server Rebuild the Kernel with I 2 O Support Activate the I 2 O Subsystem RAID Software Overview RAID Configuration Services RAID Configuration Services Administration RAID Storage Console IRVIEW Using the RAID Software Suite Using RAID Configuration Services Administration Configure a RAID Volume in a Linux System Monitor the Status of the RAID Subsystem Uninstalling RAID Software Suite Booting to Red Hat Linux on an I 2 O RAID Volume Method 1 - MBR on Primary IDE Method 2 - MBR on I 2 O RAID Volume Technical Notes Linux Dynamic Block Device Limitations Miscellaneous Notes 1.2 Software Requirements Linux RAID Software Suite CD-ROM Linux Kernel I 2 O Support (open source)* RAID Storage Console / RAID Configuration Services Utility tools (Command Line tool: irview) Red Hat Linux 6.x (installed on your machine) Root access on the Linux server RAID Software Suite for Linux User s Guide Rev
6 Install the RAID Software Suite onto an Existing Linux Server Hard disk space: Minimum 20 MB *The I 2 O kernel modules were developed as an Open Source project. These modules were developed for two kernel versions: 2.2.x (current stable versions) and 2.3.x (development version leading to 2.4 version). The modules can be obtained along with the latest kernel sources from ftp://ftp.kernel.org/pub/linux/kernel/. We suggest you obtain the very latest modules. This CD-ROM contains the 2.2.x version of the I 2 O modules. 1.3 Install the RAID Software Suite onto an Existing Linux Server Installation 1. Place the Linux RAID Software Suite CD-ROM in the CD-ROM Drive. If the installation does not automatically begin, then mount the CD-ROM: $ mount /dev/cdrom /mnt/cdrom and run the install script: $/mnt/cdrom/autorun If an X Windows is not available, then run the install script: $/mnt/cdrom/install 2. Install the software. Select Yes to continue the installation. Select No to cancel the installation. See Figure 1-1. Note: Ignore warning messages printed out on the console during installation. If the install script detects a fatal failure, it will automatically exit the program. Figure 1-1. Installation Confirmation 1-6 RAID Software Suite for Linux User s Guide Rev 1.001
7 Install the RAID Software Suite onto an Existing Linux Server 3. Install the kernel sources with I 2 O support (supplied with the CD-ROM). Note: check Linux kernel source sites for the latest Kernel source code (later than Linux ). See Figure 1-2. a. If you select Yes, the screen in Figure 1-3 appears. When you install the kernel sources supplied by the installation program, then the sources are unpacked in the /usr/src directory and appropriately linked to the /usr/src/linux directory. b. If you wish to install source code later than Linux , select No. The screen in Figure 1-4 appears. The source code on the CD-ROM is not installed and the remaining components of the software suite are installed. Figure 1-2. Install the Kernel Sources Figure 1-3. Install Kernel Sources from Install Program RAID Software Suite for Linux User s Guide Rev
8 Install the RAID Software Suite onto an Existing Linux Server Figure 1-4. Bypass Installation of Kernel Source Code 4. Install version or a later version of Kaffe Java. Check the version of Kaffe installed on your machine, with the command "rpm -q kaffe". If your version of Kaffe Java is later than 1.0.5, then select No, otherwise select Yes. See Figure 1-5. Note: to use the RAID Configuration Service, you must have "Java Runtime Environment" installed on your machine. Kaffe is an open-source Java initiative, which is also supplied with Red Hat Linux. Figure 1-5. Install Java 5. Complete the installation by clicking on OK in the screens. 6. Rebuild the kernel. See Section Complete the installation by starting RAID Configuration Services (see Section ) and configuring RAID volumes using RAID Storage Console (see Section ). 1-8 RAID Software Suite for Linux User s Guide Rev 1.001
9 Install the RAID Software Suite onto an Existing Linux Server Rebuild the Kernel with I 2 O Support The Linux RAID Software Suite installation program will install the latest kernel source with I 2 O support in the /usr/src/linux directory. You must rebuild the kernel with I 2 O support. I 2 O support can be either statically linked with the kernel or it can be built as kernel modules. The kernel can be built with many options and should be customized for your particular machine. 1. Type the following at the command line: $ cd /usr/src/linux then $ make xconfig The screen in Figure 1-6 appears. Figure 1-6. Linux Kernal Configuration 2. Configure I 2 O support. Click on the I 2 O support button on the Kernel Configuration screen. See Figure 1-6. a. Enable I 2 O support in the kernel. Select one of the following methods: Statically build I 2 O support into the new kernel. Select "y" to the relevant I 2 O choices. See Figure 1-7. Build the I 2 O support as kernel modules. Select "m" to the relevant I 2 O choices. See Figure 1-8. To be able to use the RAID Software Suite, two components of I 2 O, I 2 O PCI support and I 2 O Block OSM, are required. Other components are optional. RAID Software Suite for Linux User s Guide Rev
10 Install the RAID Software Suite onto an Existing Linux Server Figure 1-7. Configuring I 2 O Support in the Kernel Figure 1-8. Configuring I 2 O Support as Kernel Modules 3. Once you have completely configured the kernel, save your configuration and build the kernel and modules as appropriate. $ make dep $ make clean $ make bzimage $ cp /usr/src/linux/boot/arch/i386/bzimage /boot/vmlinuzyourlabel $ make modules $ make modules_install Additional reading for configuring and rebuilding the Linux kernel: /usr/src/linux/readme Linux Kernel Configuration HOWTO at HOWTO.html 4. Make relevant changes to /etc/lilo.conf per the following example: Before example: image=/boot/vmlinuz RAID Software Suite for Linux User s Guide Rev 1.001
11 Install the RAID Software Suite onto an Existing Linux Server label=linux initrd=/boot/initrd img read-only root=/dev/hda2 After example: image=/boot/vmlinuz-2.x.x-label label=mylabel initrd=/boot/initrd img read-only root=/dev/hda2 5. Run /sbin/lilo. See Linux Loader (LILO) HOWTO at HOWTO/mini/LILO.html for more information. 6. Reboot your machine and load the new kernel. 7. If you build I 2 O support with kernel modules, you must activate the I 2 O subsystem as described in Section Activate the I 2 O Subsystem If you built the I 2 O support statically into the kernel, then the RAID controller card will be automatically detected at bootup. If you built the kernel with I 2 O support as kernel modules, you must load the kernel modules. 1. Run the following commands: $ modprobe i2o_block then $ modprobe i2o_config 2. Confirm that the modules were loaded properly using the lsmod command. Type the following on the command line: $ lsmod The following output appears: Module Size Used by i2o_config i2o_block i2o_core [i2o_config i2o_block] i2o_pci [i2o_core] For more information on Linux Kernel modules read /usr/src/linux/documentation/ modules.txt RAID Software Suite for Linux User s Guide Rev
12 RAID Software Overview 1.4 RAID Software Overview RAID Configuration Services The RAID Configuration Services allow you to configure your RAID volumes, disks and arrays. You must start RAID Configuration Services before configuring your RAID volume. Type the following at the command line: $ /opt/iir/bin/iird start stop restart Access the RAID Configuration Services Administration through the shortcut located off of the system branch of your GNOME/KDE start menu. This program may be called from any of the init scripts at boot-up and shutdown time. However, the RAID Configuration Services are only required to run when you are configuring the RAID subsystem with RAID Storage Console. Once the RAID subsystem configuration is completed, you may wish to stop RAID Configuration Services to free system resources RAID Configuration Services Administration The RAID Configuration Services Administration utility is used to configure parameters of the RAID Configuration Services. This X Windows program provides the ability to manage user access, TCP/IP port settings, and remote access of the RAID Configuration Services. An alternative to using the RAID Configuration Services Administration utility is to manually edit the /opt/iir/iirserver/etc/config.iir text file and restart the RAID Configuration Services RAID Storage Console The RAID Storage Console is an HTML-based configuration utility that is used to configure the RAID subsystem. The RAID Storage Console can be accessed locally or remotely. Local Access the local RAID Storage Console through the shortcut located off of the system branch of your GNOME/KDE start menu. Remote The RAID Storage Console can also be accessed remotely. If you want to access it remotely, use a web-browser and point it to: RAID Software Suite for Linux User s Guide Rev 1.001
13 Using the RAID Software Suite The RAID storage console is under restricted access. For authorized access, use the following initial username/password pair: root/root Warning: Change the default password and /or username immediately after the installation. Failing to do so is a security risk. Refer to Section for instructions. See the RAID Controller User s Manual for a complete description of the RAID Storage Console utility and its usage IRVIEW IRVIEW is a command line utility that provides real-time status of the RAID subsystem. 1.5 Using the RAID Software Suite Using RAID Configuration Services Administration 1. Start the RAID Configuration Services Administration program by running: $ /opt/iir/bin/iradmin or Access the RAID Configuration Services Administration through the shortcut located off of the system branch of your GNOME/KDE start menu. The screen in Figure 1-9 appears. Figure 1-9. RAID Configuration Services Administration 2. Modify the port and remote access settings of the RAID Configuration Services. Click the button labeled Edit Configuration. See Figure RAID Software Suite for Linux User s Guide Rev
14 Using the RAID Software Suite Figure RAID Configuration Services Administration - Edit Configuration The following parameters are available: CGI File: This parameter indicates the interface to the I/O processor and should not be changed. PORT: This is the TCP/IP port used to access the CGI file. Default value is 960. Access type: This parameter indicates whether or not RAID Storage Console can be accessed from a remote server. The default value of LOCAL. For remote access, change the value to REMOTE. After any change to the RAID Configuration Server, restart the server with the following command: /opt/iir/bin/iird restart 3. To manage user access of the RAID Configuration Services, click on the User Management button on the screen in Figure 1-9. The screen in Figure 1-11 appears. Figure RAID Configuration Services Administration - User Management To add a new user, enter a new user name in the text field and click the button labeled Add. Enter a new password at the prompt. See Figure RAID Software Suite for Linux User s Guide Rev 1.001
15 Using the RAID Software Suite Figure User Management Add User Screen To change the password of an existing user, enter an existing username and click on Change. Complete the password prompts as directed. See Figure Figure User Management Change Password User Management changes do not require a restart of the RAID Configuration Services to take effect Configure a RAID Volume in a Linux System Warning: See Section 1.7.1, Linux Dynamic Block Device Limitations on page Understanding the information in this section is critical to completing the following procedures. 1. Use a web browser and point to: to create RAID volumes. Or click on the Raid Storage Console icon on your desktop. Use fdisk to create partitions on the RAID volumes using the following command: $ fdisk /dev/i2o/hd [a : first RAID volume - p : sixteenth volume created] Note: All I 2 O devices created are represented as "device files" on a Linux system. These device files are: /dev/i2o/hda to /dev/i2o/hdp for a total of 16 volumes that can be created. Individual partitions can be accesses (after creation using fdisk) as /dev/i2o/ hda1, /dev/i2o/hda2 /dev/i2o/hdp4 2. Make Linux native filesystem (ext2) using the following command: RAID Software Suite for Linux User s Guide Rev
16 Using the RAID Software Suite $ mke2fs /dev/i2o/hd [a-p][1-15: the partition number] Note: kernel. Use mkfs to create any type of filesystem that is supported by your Linux system/ 3. Mount the partition on a directory (create one if necessary): $ mkdir /mnt/i2o $ mount /dev/i2o/hd [a-f][1-15] /mnt/i2o Check the RAID volume as a mounted directory with the following command: $ df -k The following output appears: Filesystem 1k-blocks Used Available Use% Mounted on /dev/hda % / /dev/i2o/hda % /mnt/i2o [root@localhost /root]# Monitor the Status of the RAID Subsystem Monitor the status of the RAID subsystem by using the command line utility called irview. To invoke this utility, type /usr/local/bin/irview on the command line. To get more information on irview, invoke the corresponding man page (man irview). A sample irview screen is shown in Figure Figure irview Screen 1-16 RAID Software Suite for Linux User s Guide Rev 1.001
17 Booting to Red Hat Linux on an I 2 O RAID Volume Uninstalling RAID Software Suite To uninstall the RAID Software Suite run the following: /opt/iir/bin/uninstall Note: The uninstall program will not remove the kernel sources or installed modules. 1.6 Booting to Red Hat Linux on an I 2 O RAID Volume There are two methods available for booting Red Hat Linux from an I 2 O RAID Controller. The first method installs Red Hat Linux on an IDE or SCSI hard drive and loads LILO (the Linux Loader) from the Master Boot Record (MBR) on that original drive (/dev/hda), which then loads the Linux kernel which is located on a disk or volume connected to the I 2 O RAID Controller. The second method installs LILO onto the MBR of the I 2 O boot device (/dev/i2o/hda) and allows the system to boot directly from a disk or volume connected to the I 2 O RAID Controller. Warning: See Section 1.7.1, Linux Dynamic Block Device Limitations on page Understanding the information in this section is critical to completing the following procedures Method 1 - MBR on Primary IDE Method 1 assumes that you have installed Red Hat Linux 6.x on the primary IDE drive (/ dev/hda). Although an IDE drive is assumed for these instructions, Method 1 could be used when Red Hat Linux is installed on a SCSI hard drive. For example, the boot device file might change depending on the installation. Once you have completed the Red Hat installation, install the I 2 O kernel as described in Section 1.3.2, Rebuild the Kernel with I 2 O Support on page 1-9. After the RAID Software Suite installation is completed and the system is rebooted with I 2 O support, follow the steps below to boot your system from the I 2 O drive. 1. Create a primary I 2 O volume that is large enough to accommodate your Red Hat installation. 2. Create a /dev/i2o/hda1 partition on the primary I 2 O volume. Ensure that the partition is equal to or greater than the partition /dev/hdal (it is assumed that your Redhat System is installed on /dev/hda1). If your volume is > 8 GB, you must ensure that the partition fits within the first 1024 cylinders of the disk. 3. A modified version of LILO is provided on the RAID Software Suite CD-ROM at / mnt/cdrom/iir_install/lilo/lilo-i2o. Copy it as /sbin/lilo-i2o and make it executable. 4. Copy the contents of the system drive to the new I 2 O partition: $ dd if=/dev/hda1 of=/dev/i2o/hda1 5. Mount the I 2 O partition on a file system mount point: RAID Software Suite for Linux User s Guide Rev
18 Booting to Red Hat Linux on an I 2 O RAID Volume $ mount /dev/i2o/hda1 /mnt/i2o -t ext2 6. Edit /etc/lilo.conf and add the following boot entry: image=/mnt/i2o/boot/vmlinuz-i2o-version # Put your i2o kernel version here label=boot-i2o root=/dev/i2o/hda1 read-only 7. Edit /mnt/i2o/etc/fstab. Change the following line: /dev/hda1 / ext2 defaults 1 1 to read: /dev/i2o/hda1 / ext2 defaults 1 1 The above line will cause the kernel to mount /dev/i2o/hda1 as the root file system. 8. Run LILO with I 2 O support using this command: $ /sbin/lilo-i2o 9. Reboot Method 2 - MBR on I 2 O RAID Volume Method 2 assumes that you have installed Red Hat Linux 6.x on the primary IDE drive (/ dev/hda). Copy the Linux kernal, LILO, and the MBR to a RAID volume that is connected to the I 2 O RAID controller. To boot from the RAID volume, a modified version of the LILO binary is required. This modified version ignores the existence of IDE drives on the system. Note: This boot method differs from the way that Linux and LILO are designed to function. The LILO boot loader provided in the 2.2.x kernel has a limitation that does not allow the system to boot from a non-ide drive if an IDE drive exists. The modified LILO bypasses this requirement by ignoring the fact that there maybe devices other than the I 2 O device on the system. However if you have other IDE devices on your system, you may experience problems with those devices when using method 2. Once you have completed the Red Hat installation, install the I 2 O kernel as described in Section 1.3.2, Rebuild the Kernel with I 2 O Support on page 1-9. After RAID Software Suite installation is completed and the system is rebooted with I 2 O support, follow the steps below to boot your system from the I 2 O drive. 1. Create a primary I 2 O volume that is large enough to accommodate your Red Hat installation. 2. Create a /dev/i2o/hda1 partition on the primary I 2 O volume. Ensure that the partition is equal to or greater than the partition /dev/hdal (it is assumed that your Redhat System is installed on /dev/hda1). If your volume is > 8 GB, you must ensure that the partition fits within the first 1024 cylinders of the disk RAID Software Suite for Linux User s Guide Rev 1.001
19 Booting to Red Hat Linux on an I 2 O RAID Volume 3. A modified version of LILO is provided on the RAID Software Suite CD-ROM at / mnt/cdrom/iir_install/lilo/lilo-i2o-hack. Copy it as /sbin/liloi2o-hack and make it executable. 4. Copy the contents of the system drive to the new I 2 O partition: $ dd if=/dev/hda1 of=/dev/i2o/hda1 5. Mount the I 2 O partition on a file system mount point: $ mount /dev/i2o/hda1 /mnt/i2o -t ext2 6. Edit /mnt/i2o/etc/lilo.conf to read as follows: boot=/dev/i2o/hda map=/mnt/i2o/boot/map install=/mnt/i2o/boot/boot.b prompt timeout=20 image=/mnt/i2o/boot/vmlinuz-i2o-version # Your kernel w/i2o support label=linux root=/dev/i2o/hda1 read-only 7. Edit /mnt/i2o/etc/fstab. Change the following line: /dev/hda1 / ext2 defaults 1 1 to read: /dev/i2o/hda1 / ext2 defaults 1 1 The above line will cause the kernel to mount /dev/i2o/hda1 as the root file system. 8. Change your swap drive from the IDE drive partition (assumed to be /dev/hda5) to the I 2 O RAID volume by changing the following line in /mnt/i2o/etc/fstab: /dev/hda5 swap swap defaults 0 0 to read: /dev/i2o/hda2 swap swap defaults Run the modified LILO binary with the LILO configuration on the I 2 O RAID volume: $ /sbin/lilo-i2o-hack -C.mnt/i2o/etc/lilo.conf 10. Shutdown the system: $ shutdown -h now 11. Remove the IDE drive and restart the system. 12. Once the system has powered up, clean up /etc/lilo.conf by changing the map point reference as indicated below. This will make future updates of the kernel on the I 2 O device easier. boot=/dev/i2o/hda map=/mnt/i2o/boot/map install=/mnt/i2o/boot/boot.b RAID Software Suite for Linux User s Guide Rev
20 Technical Notes prompt timeout=20 image=/mnt/i2o/boot/vmlinuz-i2o-version # Your kernel w/i2o support label=linux root=/dev/i2o/hda1 read-only In the future, if you edit lilo.conf, run LILO w/i 2 O support (lilo-i2o) instead of the modified LILO (i.e lilo-i2o-hack). 1.7 Technical Notes Linux Dynamic Block Device Limitations The RAID volumes created using the I 2 O Linux drivers are seen by Linux as "Block Devices". The RAID Software Suite gives a powerful new feature to create new block devices while a Linux system is up and running via the use of the Storage Console. The new RAID volume created is detected as /dev/i2o/hd* and can be immediately used as a normal block storage device. This block device was dynamically created while the system was up and running and is associated to a particular device file (/dev/i2o/hd*) and a Major/Minor number, however, Linux does not associate a physical storage device with the device file (or rather the Major/Minor) number across reboots. The implication of this limitation is that when a reboot occurs after a user has dynamically created a dynamic block device, the device files associated with the physical storage device changes once the system comes back online. If there were entries in the /etc/fstab and /etc/mtab associated with these dynamc block devices, then they will no longer be valid and the system will either incorrectly mount these devices or it may not mount them at all. Your system may not boot if the root file system was also on a dynamic block device. Workarounds Create all the RAID volumes you require and reboot before you designate persistent mount points for them. Take this approach especially if you are planning to mount the root file system on a RAID volume. Avoid creating additional RAID volumes after designating one of the existing volumes as the root file system. Remove any existing entries in /etc/fstab pertaining to I 2 O devices. Create a filesystem on the new RAID volume and reboot. When the system has rebooted, examine the I 2 O block devices to determine the mapping of the physical I 2 O block devices to /dev/i2o/hd* device files. Mount the I 2 O block devices onto the desired mount points and enter the corresponding entries in the /etc/fstab config file. If you built the I 2 O support as kernel modules, then a reboot is not necessary. Simply unload and reload the I 2 O modules RAID Software Suite for Linux User s Guide Rev 1.001
21 Miscellaneous Notes 1.8 Miscellaneous Notes The /opt/iir directory requires a minimum of read, write, and execute privileges for root. RAID Software Suite for Linux User s Guide Rev
How to Configure Intel X520 Ethernet Server Adapter Based Virtual Functions on Citrix* XenServer 6.0*
How to Configure Intel X520 Ethernet Server Adapter Based Virtual Functions on Citrix* XenServer 6.0* Technical Brief v1.0 December 2011 Legal Lines and Disclaimers INFORMATION IN THIS DOCUMENT IS PROVIDED
Yosemite Server Backup Installation Guide
Yosemite Server Backup Installation Guide Part number: First edition: October, 2010 Legal and notice information Copyright 2004, 2012 Barracuda Networks, Inc. Under copyright laws, the contents of this
Customizing Boot Media for Linux* Direct Boot
White Paper Bruce Liao Platform Application Engineer Intel Corporation Customizing Boot Media for Linux* Direct Boot October 2013 329747-001 Executive Summary This white paper introduces the traditional
Intel Storage System SSR212CC Enclosure Management Software Installation Guide For Red Hat* Enterprise Linux
Intel Storage System SSR212CC Enclosure Management Software Installation Guide For Red Hat* Enterprise Linux Order Number: D58855-002 Disclaimer Information in this document is provided in connection with
Intel Matrix Storage Console
Intel Matrix Storage Console Reference Content January 2010 Revision 1.0 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE,
Intel Matrix Storage Manager 8.x
Intel Matrix Storage Manager 8.x User's Manual January 2009 Revision 1.0 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
Intel Rapid Storage Technology
Intel Rapid Storage Technology User Guide August 2011 Revision 1.0 1 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
Intel Server Raid Controller. RAID Configuration Utility (RCU)
Intel Server Raid Controller RAID Configuration Utility (RCU) Revision 1.1 July 2000 Revision History Date Rev Modifications 02/13/00 1.0 Initial Release 07/20/00 1.1 Update to include general instructions
Partition Alignment of Intel SSDs for Achieving Maximum Performance and Endurance Technical Brief February 2014
Partition Alignment of Intel SSDs for Achieving Maximum Performance and Endurance Technical Brief February 2014 Order Number: 330105-001US INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL
Intel RAID Volume Recovery Procedures
Intel RAID Volume Recovery Procedures Revision 1.0 12/20/01 Revision History Date Revision Number 12/20/01 1.0 Release Modifications Disclaimers Information in this document is provided in connection with
Abstract. Microsoft Corporation Published: August 2009
Linux Integration Components Version 2 for Hyper-V (Windows Server 2008, Windows Server 2008 R2, Microsoft Hyper-V Server 2008, and Microsoft Hyper-V Server 2008 R2) Readme Microsoft Corporation Published:
Intel Data Migration Software
User Guide Software Version 2.0 Document Number: 324324-002US INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY
This guide explains how to install an Intel Solid-State Drive (Intel SSD) in a SATA-based desktop or notebook computer.
Installation Guide This guide explains how to install an (Intel SSD) in a SATA-based desktop or notebook computer. The instructions include migrating your data from your current storage device (such as
iscsi Quick-Connect Guide for Red Hat Linux
iscsi Quick-Connect Guide for Red Hat Linux A supplement for Network Administrators The Intel Networking Division Revision 1.0 March 2013 Legal INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH
Support Notes for SUSE LINUX Enterprise Server 9 Service Pack 3 for the Intel Itanium 2 Processor Family
Support Notes for SUSE LINUX Enterprise Server 9 Service Pack 3 for the Intel Itanium 2 Processor Family *5991-5301* Part number: 5991-5301 Edition: 3, E0406 Copyright 2006 Hewlett-Packard Development
Intel Simple Network Management Protocol (SNMP) Subagent v6.0
Intel Simple Network Management Protocol (SNMP) Subagent v6.0 User Guide March 2013 ii Intel SNMP Subagent User s Guide Legal Information INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL
User Guide Software Version 2.1.0
Intel Solid State Drive Firmware Update Tool User Guide Software Version 2.1.0 Order Number: 322570-007US Intel disclaims all express and implied warranties, including without limitation, the implied warranties
HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions
HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions Congratulations on your purchase of the 8Gb Simple SAN Connection Kit. This guide provides procedures for installing the kit components,
Intel Entry Storage System SS4000-E
Intel Entry Storage System SS4000-E Software Release Notes March, 2006 Storage Systems Technical Marketing Revision History Intel Entry Storage System SS4000-E Revision History Revision Date Number 3 Mar
Intel HTML5 Development Environment Article Using the App Dev Center
Intel HTML5 Development Environment Article Using the App Dev Center v1.06 : 06.04.2013 Legal Information INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS
Intel Data Migration Software
User Guide April 2016 Software Version 3.0 Document Number: 324324-003US Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence
Deploying IBM Lotus Domino on Red Hat Enterprise Linux 5. Version 1.0
Deploying IBM Lotus Domino on Red Hat Enterprise Linux 5 Version 1.0 November 2008 Deploying IBM Lotus Domino on Red Hat Enterprise Linux 5 1801 Varsity Drive Raleigh NC 27606-2072 USA Phone: +1 919 754
Intel Active Management Technology with System Defense Feature Quick Start Guide
Intel Active Management Technology with System Defense Feature Quick Start Guide Introduction...3 Basic Functions... 3 System Requirements... 3 Configuring the Client System...4 Intel Management Engine
Resetting USB drive using Windows Diskpart command
Resetting USB drive using Windows Diskpart command Simon Huang Technical Product Manager [email protected] Super Talent Technology October, 2013 Release 1.00 1 Legal Disclaimer INFORMATION IN
System Image Recovery* Training Foils
Intel-powered Classmate PC System Image Recovery* Training Foils Version 1.0 1 *Other names and brands may be claimed as the property of others. Legal Information INFORMATION IN THIS DOCUMENT IS PROVIDED
NI Real-Time Hypervisor for Windows
QUICK START GUIDE NI Real-Time Hypervisor Version 2.1 The NI Real-Time Hypervisor provides a platform you can use to develop and run LabVIEW and LabVIEW Real-Time applications simultaneously on a single
Intel Compute Stick STCK1A32WFC User Guide. Intel Compute Stick STCK1A32WFC
Intel Compute Stick STCK1A32WFC User Guide 1 Revision History Revision Revisions History Date 01 First release of the Intel Compute Stick STCK1A32WFC User Guide April 2015 Disclaimer INFORMATION IN THIS
Intel HTML5 Development Environment. Tutorial Test & Submit a Microsoft Windows Phone 8* App (BETA)
Intel HTML5 Development Environment Tutorial Test & Submit a Microsoft Windows Phone 8* App v1.00 : 04.09.2013 Legal Information INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS.
Intel SSD 520 Series Specification Update
Intel SSD 520 Series Specification Update June 2012 Revision 1.0 Document Number: 327567-001US INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
Intel HTML5 Development Environment. Tutorial Building an Apple ios* Application Binary
Intel HTML5 Development Environment Tutorial Building an Apple ios* Application Binary V1.02 : 08.08.2013 Legal Information INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO
Intel Small Business Advantage (Intel SBA) Release Notes for OEMs
Intel Small Business Advantage (Intel SBA) Release Notes for OEMs Document Release Date: October 16, 2015 Legal Information INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO
Intel Retail Client Manager
October 2014 By using this document, in addition to any agreements you have with Intel, you accept the terms set forth below. You may not use or facilitate the use of this document in connection with any
Recovery BIOS Update Instructions for Intel Desktop Boards
Recovery BIOS Update Instructions for Intel Desktop Boards All BIOS update files for Intel Desktop Boards are available on Intel's Download Center at http://downloadcenter.intel.com/. Important Notes:
ASM_readme_6_10_18451.txt -------------------------------------------------------------------- README.TXT
README.TXT Adaptec Storage Manager (ASM) as of June 3, 2009 Please review this file for important information about issues and erratas that were discovered after completion of the standard product documentation.
Intel RAID Software v6.x (and newer) Upgrade/Installation Procedures
Intel RAID Software v6.x (and newer) Upgrade/Installation Procedures For Intel Server RAID Controller U3-1 and Intel Server RAID Controller U3-1L Revision 1.1 12/21/01 Date Rev Modifications 12/21/01 1.1
http://www.intel.com/performance/resources Version 2008-09 Rev. 1.0
Software Evaluation Guide for ImTOO* YouTube* to ipod* Converter and Adobe Premiere Elements* 4.0 Downloading YouTube videos to your ipod while uploading a home video to YouTube http://www.intel.com/performance/resources
System Event Log (SEL) Viewer User Guide
System Event Log (SEL) Viewer User Guide For Extensible Firmware Interface (EFI) and Microsoft Preinstallation Environment Part Number: E12461-001 Disclaimer INFORMATION IN THIS DOCUMENT IS PROVIDED IN
with PKI Use Case Guide
Intel Identity Protection Technology (Intel IPT) with PKI Use Case Guide Version 1.0 Document Release Date: February 29, 2012 Intel IPT with PKI Use Case Guide i Legal Notices and Disclaimers INFORMATION
WES 9.2 DRIVE CONFIGURATION WORKSHEET
WES 9.2 DRIVE CONFIGURATION WORKSHEET This packet will provide you with a paper medium external to your WES box to write down the device names, partitions, and mount points within your machine. You may
GigaRAID (IT8212) ATA RAID Controller USER S MANUAL
GigaRAID (IT8212) ATA RAID Controller USER S MANUAL 12ME-IT8212-006R Copyright Copyright by GIGA-BYTE TECHNOLOGY CO., LTD. ( GBT ) No part of this manual may be reproduced or transmitted in any from without
Command Line Interface User Guide for Intel Server Management Software
Command Line Interface User Guide for Intel Server Management Software Legal Information Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel
Lotus Foundations Start Getting Started
Lotus Foundations Start Getting Started Guide Contents 1 Introduction... page 2 2 Product overview... page 2 3 System Requirements... page 2 4 Summary of Installation... page 3 5 Lotus Foundations operating
Red Hat Linux 7.2 Installation Guide
Red Hat Linux 7.2 Installation Guide Ryan Spangler [email protected] http://ceut.uww.edu April 2002 Department of Business Education/ Computer and Network Administration Copyright Ryan Spangler 2002
Intel Ethernet and Configuring Single Root I/O Virtualization (SR-IOV) on Microsoft* Windows* Server 2012 Hyper-V. Technical Brief v1.
Intel Ethernet and Configuring Single Root I/O Virtualization (SR-IOV) on Microsoft* Windows* Server 2012 Hyper-V Technical Brief v1.0 September 2012 2 Intel Ethernet and Configuring SR-IOV on Windows*
USB. 16MB~2GB JetFlash. User s Manual
USB 16MB~2GB JetFlash User s Manual Introduction Table of Contents Package Contents...1 Features...1 System Requirements...2 Before Use...2 Driver Installation Driver Installation for Windows 98/98SE...3
How to Configure Intel Ethernet Converged Network Adapter-Enabled Virtual Functions on VMware* ESXi* 5.1
How to Configure Intel Ethernet Converged Network Adapter-Enabled Virtual Functions on VMware* ESXi* 5.1 Technical Brief v1.0 February 2013 Legal Lines and Disclaimers INFORMATION IN THIS DOCUMENT IS PROVIDED
II. Installing Debian Linux:
Debian Linux Installation Lab Spring 2013 In this lab you will be installing Debian Linux in a KVM (Kernel Virtual Machine). You will be guided through a series of steps to setup the network (IP addresses,
The Tor VM Project. Installing the Build Environment & Building Tor VM. Copyright 2008 - The Tor Project, Inc. Authors: Martin Peck and Kyle Williams
The Tor VM Project Installing the Build Environment & Building Tor VM Authors: Martin Peck and Kyle Williams Table of Contents 1. Introduction and disclaimer 2. Creating the virtualization build environment
Installing Sun's VirtualBox on Windows XP and setting up an Ubuntu VM
Installing Sun's VirtualBox on Windows XP and setting up an Ubuntu VM laptop will need to have 10GB of free space to install download the latest VirtualBox software from www.sun.com make sure you pick
Intel System Event Log (SEL) Viewer Utility. User Guide SELViewer Version 10.0 /11.0 December 2012 Document number: G88216-001
Intel System Event Log (SEL) Viewer Utility User Guide SELViewer Version 10.0 /11.0 December 2012 Document number: G88216-001 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH
Intel Solid-State Drive Data Center Tool User Guide Version 1.1
Intel Solid-State Drive Data Center Tool User Guide Version 1.1 Order Number: 327191-002 October 2012 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR
RAID configuration and driver installation guide
Server systems and motherboards RAID configuration and driver installation guide For AP130-E1 5U Rackmount Server AP1720-E2 5U Rackmount Server NCCH-DL Motherboard PSCH-L Motherboard E1600 First edition
readme_asm.txt -------------------------------------------------------------------- README.TXT
README.TXT Adaptec Storage Manager as of March 27, 2006 Please review this file for important information about issues and erratas that were discovered after completion of the standard product documentation.
Installation Guide. Yosemite Backup. Yosemite Technologies, Inc
Installation Guide Yosemite Backup Yosemite Technologies, Inc ii Yosemite Backup Installation Guide Notice Copyright Information in this document is subject to change without notice. makes no representations
Intel Media SDK Library Distribution and Dispatching Process
Intel Media SDK Library Distribution and Dispatching Process Overview Dispatching Procedure Software Libraries Platform-Specific Libraries Legal Information Overview This document describes the Intel Media
BackTrack Hard Drive Installation
BackTrack Hard Drive Installation BackTrack Development Team jabra [at] remote-exploit [dot] org Installing Backtrack to a USB Stick or Hard Drive 1 Table of Contents BackTrack Hard Drive Installation...3
Linux Integration Services 3.4 for Hyper-V Readme
Linux Integration Services 3.4 for Hyper-V Readme Microsoft Corporation Published: September 2012 Abstract This guide discusses the installation and functionality of Linux Integration Services for Hyper-V
PCI Express SATA / esata 6Gb/s RAID Card User Manual
PCI Express SATA / esata 6Gb/s RAID Card User Manual Specifications : - 2 x SATA 6Gb/s Port (SATA version) - 2 x esata 6Gb/s Port (esata version) - Max. 6Gb/s transfer rate per port - Supports both SATA
IDE Integration for Android* Part of the Intel Integrated Native Developer Experience (Intel INDE) 1.5.7
IDE Integration for Android* Part of the Intel Integrated Native Developer Experience (Intel INDE) 1.5.7 Overview IDE Integration for Android provides productivity-oriented design, coding, and debugging
SyAM Software* Server Monitor Local/Central* on a Microsoft* Windows* Operating System
SyAM Software* Server Monitor Local/Central* on a Microsoft* Windows* Operating System with Internal Storage Focusing on IPMI Out of Band Management Recipe ID: 19SYAM190000000011-01 Contents Hardware Components...3
Intel Multi Server Manager V2.0
Intel Multi Server Manager V2.0 Release Notes Release Date: August 2012 Build # 18 Page 1 of 9 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS FOR THE PURPOSE
Revision History. Revision Revision History Date
G001 Revision History Revision Revision History Date 1.0 First release of the Intel NUC Home Theatre Personal Computer on the Linux* Mint Platform using XBMC May 2013 2.0 Second release of the Intel NUC
Intel RAID Controller Troubleshooting Guide
Intel RAID Controller Troubleshooting Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Intel order number C18781-001 September 2, 2002 Revision History Troubleshooting
Setup Cisco Call Manager on VMware
created by: Rainer Bemsel Version 1.0 Dated: July/09/2011 The purpose of this document is to provide the necessary steps to setup a Cisco Call Manager to run on VMware. I ve been researching for a while
Intel System Event Log (SEL) Viewer Utility
Intel System Event Log (SEL) Viewer Utility User Guide Document No. E12461-003 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS FOR THE GENERAL PURPOSE OF SUPPORTING
NetVault : Backup. User s Guide for the VaultDR System Plugins
NetVault : Backup User s Guide for the VaultDR System Plugins VaultDR Offline Plugin ver. 5.6 (VaultOS) VaultDR Online Plugin for Windows ver. 3.5 VaultDR Online Plugin for Linux ver. 3.1 VaultDR Server
Dell Statistica 13.0. Statistica Enterprise Installation Instructions
Dell Statistica 13.0 2015 Dell Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in this guide is furnished under a software license or
Acronis Backup & Recovery 11.5 Quick Start Guide
Acronis Backup & Recovery 11.5 Quick Start Guide Applies to the following editions: Advanced Server for Windows Virtual Edition Advanced Server SBS Edition Advanced Workstation Server for Linux Server
Installation Guide for the Intel Server Control
Installation Guide for the Intel Server Control Order Number: 747116-007 This guide explains how to install and launch the Intel Server Control (ISC) software. ISC is a server management tool that provides
Overview of ServerView Windows Agent This chapter explains overview of ServerView Windows Agent, and system requirements.
ServerView User s Guide (For Windows Agent) Areas Covered - Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview of ServerView
Intel Desktop Board D945GCPE
Intel Desktop Board D945GCPE Specification Update January 2009 Order Number: E11670-003US The Intel Desktop Board D945GCPE may contain design defects or errors known as errata, which may cause the product
EHCI Removal from 6 th Generation Intel Core Processor Family Platform Controller Hub (PCH)
EHCI Removal from 6 th Generation Intel Core Processor Family Platform Controller Hub (PCH) Technical White Paper September 2015 Revision 1.0 333136-001 You may not use or facilitate the use of this document
Intel Desktop Board D101GGC Specification Update
Intel Desktop Board D101GGC Specification Update Release Date: November 2006 Order Number: D38925-003US The Intel Desktop Board D101GGC may contain design defects or errors known as errata, which may cause
Intel Integrated Native Developer Experience (INDE): IDE Integration for Android*
Intel Integrated Native Developer Experience (INDE): IDE Integration for Android* 1.5.8 Overview IDE Integration for Android provides productivity-oriented design, coding, and debugging tools for applications
Symantec LiveUpdate Administrator. Getting Started Guide
Symantec LiveUpdate Administrator Getting Started Guide Symantec LiveUpdate Administrator Getting Started Guide The software described in this book is furnished under a license agreement and may be used
Remote Control 5.1.2. Tivoli Endpoint Manager - TRC User's Guide
Tivoli Remote Control 5.1.2 Tivoli Endpoint Manager - TRC User's Guide Tivoli Remote Control 5.1.2 Tivoli Endpoint Manager - TRC User's Guide Note Before using this information and the product it supports,
Intel System Event Log (SEL) Viewer Utility
Intel System Event Log (SEL) Viewer Utility User Guide Document No. E12461-005 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS FOR THE GENERAL PURPOSE OF SUPPORTING
Fuse ESB Enterprise Installation Guide
Fuse ESB Enterprise Installation Guide Version 7.1 December 2012 Integration Everywhere Installation Guide Version 7.1 Updated: 08 Jan 2014 Copyright 2012 Red Hat, Inc. and/or its affiliates. Trademark
VERITAS Backup Exec TM 10.0 for Windows Servers
VERITAS Backup Exec TM 10.0 for Windows Servers Quick Installation Guide N134418 July 2004 Disclaimer The information contained in this publication is subject to change without notice. VERITAS Software
Virtual Appliance for VMware Server. Getting Started Guide. Revision 2.0.2. Warning and Disclaimer
Virtual Appliance for VMware Server Getting Started Guide Revision 2.0.2 Warning and Disclaimer This document is designed to provide information about the configuration and installation of the CensorNet
www.cristie.com CBMR for Linux v6.2.2 User Guide
www.cristie.com CBMR for Linux v6.2.2 User Guide Contents CBMR for Linux User Guide - Version: 6.2.2 Section No. Section Title Page 1.0 Using this Guide 3 1.1 Version 3 1.2 Limitations 3 2.0 About CBMR
Intel Desktop Board DG41BI
Intel Desktop Board DG41BI Specification Update July 2010 Order Number: E88214-002US The Intel Desktop Board DG41BI may contain design defects or errors known as errata, which may cause the product to
SonicWALL Global Management System Installation Guide Entry Edition. Version 2.1
SonicWALL Global Management System Installation Guide Entry Edition Version 2.1 Copyright Information 2001 SonicWALL, Inc. All rights reserved. Under the copyright laws, this manual or the software described
Intel System Event Log (SEL) Viewer Utility
Intel System Event Log (SEL) Viewer Utility User Guide Document No. E12461-007 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS FOR THE GENERAL PURPOSE OF SUPPORTING
Intel Cloud Builder Guide: Cloud Design and Deployment on Intel Platforms
EXECUTIVE SUMMARY Intel Cloud Builder Guide Intel Xeon Processor-based Servers Red Hat* Cloud Foundations Intel Cloud Builder Guide: Cloud Design and Deployment on Intel Platforms Red Hat* Cloud Foundations
Software Evaluation Guide for Autodesk 3ds Max 2009* and Enemy Territory: Quake Wars* Render a 3D character while playing a game
Software Evaluation Guide for Autodesk 3ds Max 2009* and Enemy Territory: Quake Wars* Render a 3D character while playing a game http://www.intel.com/performance/resources Version 2008-09 Rev. 1.0 Information
Intel Retail Client Manager
Intel Retail Client Manager Frequently Asked Questions June 2014 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO
Installing and Configuring the Intel Server Manager 8 SNMP Subagents. Intel Server Manager 8.40
Installing and Configuring the Intel Server Manager 8 SNMP Subagents Intel Server Manager 8.40 Legal Information This Installing and Configuring the Intel Server Manager 8 SNMP Subagents--Intel Server
Installation Guide. Novell Storage Manager 3.1.1 for Active Directory. Novell Storage Manager 3.1.1 for Active Directory Installation Guide
Novell Storage Manager 3.1.1 for Active Directory Installation Guide www.novell.com/documentation Installation Guide Novell Storage Manager 3.1.1 for Active Directory October 17, 2013 Legal Notices Condrey
Dialogic System Release 6.0 PCI for Windows
Dialogic System Release 6.0 PCI for Windows Software Installation Guide March 2009 05-1957-004 Copyright and Legal Notice Copyright 2003-2009,. All Rights Reserved. You may not reproduce this document
How to Backup XenServer VM with VirtualIQ
How to Backup XenServer VM with VirtualIQ 1. Using Live Backup of VM option: Live Backup: This option can be used, if user does not want to power off the VM during the backup operation. This approach takes
RocketRAID 2640/2642 SAS Controller Ubuntu Linux Installation Guide
RocketRAID 2640/2642 SAS Controller Ubuntu Linux Installation Guide Version 1.2 Copyright 2012 HighPoint Technologies, Inc. All rights reserved. Last updated on June 14, 2012 Table of Contents 1 Overview...
Abstract. Microsoft Corporation Published: November 2011
Linux Integration Services Version 3.2 for Hyper-V (Windows Server 2008, Windows Server 2008 R2, Microsoft Hyper-V Server 2008, and Microsoft Hyper-V Server 2008 R2) Readme Microsoft Corporation Published:
MarkLogic Server. Installation Guide for All Platforms. MarkLogic 8 February, 2015. Copyright 2015 MarkLogic Corporation. All rights reserved.
Installation Guide for All Platforms 1 MarkLogic 8 February, 2015 Last Revised: 8.0-4, November, 2015 Copyright 2015 MarkLogic Corporation. All rights reserved. Table of Contents Table of Contents Installation
Installing the Operating System or Hypervisor
Installing the Operating System or Hypervisor If you purchased E-Series Server Option 1 (E-Series Server without preinstalled operating system or hypervisor), you must install an operating system or hypervisor.
Deploying a Virtual Machine (Instance) using a Template via CloudStack UI in v4.5.x (procedure valid until Oct 2015)
Deploying a Virtual Machine (Instance) using a Template via CloudStack UI in v4.5.x (procedure valid until Oct 2015) Access CloudStack web interface via: Internal access links: http://cloudstack.doc.ic.ac.uk
Intel Desktop Board DG41WV
Intel Desktop Board DG41WV Specification Update April 2011 Part Number: E93639-003 The Intel Desktop Board DG41WV may contain design defects or errors known as errata, which may cause the product to deviate