MODELS HSUL-J HST-J HS115-J HSUL-1 HST-1 HS115-1 HSUL-2 HST-2 HS115-2
|
|
|
- Marilyn Boyd
- 9 years ago
- Views:
Transcription
1 REV. A 11/99 TJERNLUND PRODUCTS, INC Ninth Street White Bear Lake, MN PHONE (800) (651) FAX (651) Visit our web site FOR NATURAL GAS, LP OR OIL MODELS HSUL-J HST-J HS-J HSUL-1 HST-1 HS-1 HSUL-2 HST-2 HS-2 OWNER INSTRUCTIONS, DO NOT DESTROY! Recognize this symbol as an indication of important Safety Information! NOTE: FLUE GAS TEMPERATURES MUST NOT EXCEED 600 O F AT VENT SYSTEM INLET. THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUST- MENT, SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRI- CAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, OR PERSONAL INJURY OR PROPERTY DAMAGE. DO NOT DESTROY. PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE ON JOB SITE FOR FUTURE REFERENCE. Copyright 1999, Tjernlund Products, Inc. All rights reserved. P/N
2 TABLE OF CONTENTS PAGE(S) SIZING TABLES AND SPECIFICATIONS... 1 INSTALLATION RESTRICTIONS... 2 CAUTIONS... 2 GENERAL INFORMATION... 3 SAFETY INSPECTION OF EXISTING APPLIANCE INSTALLATION... 3 INSTALLATION... 4 VENT SYSTEM TERMINATION... 4 CODE REQUIREMENTS... 4 POWER VENTER INSTALLATION... 5 CODE REQUIREMENTS... 5 INSTALLATION RESTRICTIONS POWER VENTER MOUNTING... 6 DRAFT CONTROL INSTALLATION ON AN INDUCED DRAFT GAS APPLIANCE... 7 ELECTRICAL WIRING...8 WIRING RESTRICTIONS... 8 SEQUENCE OF OPERATION... 8 GAS DIAGRAMS HSUL SERIES WIRED TO 24V GAS VALVE... 9 HST SERIES WIRED TO 24V GAS VALVE HSUL SERIES GAS WIRING WITH SINGLE ZONE 24V THERMOSTAT HST SERIES GAS WIRING WITH SINGLE ZONE 24V THERMOSTAT HS SERIES WIRED TO V GAS VALVE OR BURNER MOTOR HSUL SERIES WIRED TO HONEYWELL SMART VALVE OIL DIAGRAMS HST SERIES OIL WIRING WITH SINGLE ZONE 24V THERMOSTAT HST SERIES WIRED TO HONEYWELL R8184 SERIES PRIMARY OR EQUIVALENT HST SERIES WIRED TO AN AQUASTAT OR CARLIN CONTROL DRAFT CHECK AND SAFETY INTERLOCK / COMBUSTION AIR TEST HST SERIES POST PURGE TIMER ADJUSTMENT MAINTENANCE TROUBLESHOOTING GUIDE HOW TO OBTAIN SERVICE & LIMITED WARRANTY Tjernlund Products welcomes your comments and questions. Call us at , Fax , us at [email protected] or write to: Customer Service, Tjernlund Products, Inc., 1601 Ninth Street, White Bear Lake, MN HS-SERIES MODEL SELECTION TABLE SPECIFICATIONS POWER VENTER DIMENSIONS NOTE: Oil applications must use HST Series which include integral post-purge Relay/Timer IMPORTANT Table footage is based on equivalent vent pipe length. To calculate equivalent vent pipe length, add the straight vent pipe plus 10 for every 90 O elbow and 5 for every 45 O elbow. If venting multiple appliances with one Power Venter, the total combined BTU/hr. input of all appliances must be added together to size the Power Venter. 1 MODEL HSUL-J HST-J HS-J HSUL-1 HST-1 HS-1 HSUL-2 HST-2 HS-2 MOTOR VOLTAGE CONTROL VOLTAGE 24 24/ 24 24/ 24 24/ HZ RPM WATTS AMPS THERM. PROT. YES YES YES YES YES YES YES YES YES
3 INSTALLATION RESTRICTIONS 1. This device must be installed by a qualified professional installer in accordance with these instructions. If improperly installed, a hazardous condition such as explosion or carbon monoxide poisoning could result. 2. Do not install the Power Venter on incinerators, incinerating toilets, condensing type appliances or solid-fuel burning appliances. 3. The Power Venter shall only be installed on Natural Gas, LP or Oil-fired appliances. 4. Do not install the Power Venter on an appliance with an automatic valve having a manual opener unless the manual opener has been rendered inoperative or the automatic valve has been replaced with a valve not equipped with a manual opener. 5. The Power Venter may only be installed on appliances equipped with a draft hood, draft diverter or barometric draft control. 6. The Power Venter shall not be installed where flue gas temperatures exceed F. at Power Venter inlet. FLUE GAS TEMPERATURE VERIFICATION: A) Consult appliance manufacturer for temperature of gases at the appliance outlet after dilution by draft hood, draft diverter or barometric draft control. AND B) Measure temperature of flue gases at the Power Venter inlet at time of installation. Temperature should be measured after appliance and Power Venter have operated for at least 15 minutes, allowing flue gas temperature to stabilize. Flue gas temperature at Power Venter inlet must not exceed F. 7. The electrical load controlled through the Fan Proving Switch must not exceed the electrical ratings marked on the Fan Prover. 8. The appliance(s) may only be installed on the suction side of Power Venter. Improper installation, adjustment, alterations, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency, gas or oil supplier. CAUTIONS Failure to install, maintain and/or operate the Power Venter in accordance with manufacturer's instructions may result in conditions which can produce bodily injury and property damage. The Power Venter must be installed by a qualified installer in accordance with these instructions and all local codes or in their absence in accordance with the latest edition of The National Fuel Gas Code (ANSI Z223.1/NFPA #54), NFPA # 31 Oil Burning Equipment, the latest edition of the National Electrical Code (NFPA#70) and the Occupational Safety and Health Act (OSHA) when applicable. Improper installation can create a hazardous condition such as an explosion, fire, electrical shock or carbon monoxide poisoning resulting in property damage, personal injury or death. Qualified Installer shall mean an individual properly trained and licensed. Disconnect the power supply when making wiring connections or when working around the fan wheel and motor. Failure to do so can result in electrical shock, personal injury, death or property damage. 1. In order to comply with the UL Listing of the Power Venters the Fan Prover must be wired with the appliance so as to prevent the main burner(s) from firing if the Power Venter malfunctions or the flue is blocked. It is not safe to use the Power Venter on millivolt appliances, such as water heaters which employ a combination gas valve/temperature controller, since the Fan Prover can not be wired as described in this booklet. Millivolt appliances require additional, accessory controls. 2. Plan the vent system so that Code required distances are maintained from plumbing and wiring. 3. The Power Venter motor shaft must be mounted horizontally to ensure proper operation of the Fan Proving Switch and prevent motor bearing wear. 4. Make certain the power supply is adequate for the fan motor requirements. Do not add the Power Venter to a circuit where the total load is unknown. 5. The installer must verify that the BTU/hr. input of the appliance does not exceed the recommended input of the Power Venter. See selection table on page 1 of these instructions for sizing information. 6. Flue gas temperatures must not exceed F. at the Power Venter inlet. Ambient temperatures surrounding Power Venter must not exceed F. See Flue Gas Temperature Verification, item # 6 above. 7. Safety Inspection Of a Previously Used Appliance (Page 3) must be performed before installation on previously used equipment. 2
4 GENERAL INFORMATION These units have been factory tested and rated in accordance with AMCA standard 210, Test Code for Air Moving Devices. Each Power Venter is electrically factory line tested before shipment. After opening carton, inspect thoroughly for hidden damage. Wheel should rotate freely. If any damage is found notify freight carrier and your distributor immediately and file a concealed damage claim. IMPORTANT The HSUL, HS and HST Series Power Venters may be used for gas fired appliances The HST Series Power Venters are the only HS units designed for oil and include integral post-purge Relay/Timer. SAFETY INSPECTION OF A PREVIOUSLY USED GAS APPLIANCE (Perform prior to Power Venter installation) The following procedure is intended as a guide to aid in determining that an appliance is properly installed and is in safe condition for continuing use. The following procedure is based on central furnace and boiler installations and it should be recognized that generalized procedures cannot anticipate all situations. Accordingly, in some cases deviation from this procedure may be necessary to determine safe operation of the equipment. a. Perform this procedure prior to any attempt at modifications of the appliance or installation of the Power Venter. b. If it is determined there is a condition which could result in unsafe operation, shut off the appliance and advise the owner of the unsafe condition. Follow the steps below in making the safety inspection: 1. Conduct a gas leakage test of the appliance piping and control system downstream of the shutoff valve in the supply line to the appliance. 2. Visually inspect the venting system and determine there is no blockage or restriction, leakage, corrosion and other deficiencies which could cause an unsafe condition. 3. Shut off all gas to the appliance(s). 4. Inspect burners and crossovers for blockage and corrosion. 5. Applicable only to furnaces: Inspect heat exchanger for cracks, openings or excessive corrosion. Check both the limit control and fan control for proper operation. 6. Applicable only to boilers: Inspect for evidence of water or combustion product leaks. Determine that the water pumps are in operating condition. Test low water cutoffs, automatic feed controls, pressure and temperature limit controls and relief valves in accordance with the manufacturer's recommendations to determine that they are in operating order. * Excerpts from the National Fuel Gas Code (ANSI Z223.1/NFPA #54), Appendix H. SAFETY INSPECTION OF A PREVIOUSLY USED OIL APPLIANCE (Perform prior to Power Venter installation) The following procedure is intended as a guide to aid in determining that an appliance is properly installed and is in safe condition for continuing use. This procedure is based on central furnace and boiler installations and it should be recognized that generalized procedures cannot anticipate all situations. Accordingly, in some cases deviation from this procedure may be necessary to determine safe operation of the equipment. a. This procedure should be performed prior to any attempt at modifications of the appliance or installation of the Power Venter. b. If it is determined there is a condition which could result in unsafe operation, the appliance should be shut off and the owner advised of the unsafe condition. The following steps should be followed in making the safety inspection: 1. Visually inspect the venting system and determine there is no blockage or restriction, leakage, corrosion or other deficiencies which could cause an unsafe condition. 2. Inspect burner and primary control for proper operation. 3. Applicable only to furnaces: Inspect heat exchanger for cracks, openings or excessive corrosion. Check both the limit control and fan control for proper operation. 4. Applicable only to boilers: Inspect for evidence of water or combustion product leaks. Determine that the water pumps are in operating condition. Test low water cutoffs, automatic feed controls, pressure and temperature limit controls and relief valves in accordance with the manufacturer's recommendations to determine that they are in operating order. * Excerpts from the National Fuel Gas Code (ANSI Z223.1/NFPA #54), Appendix H. 3
5 INSTALLATION VENT SYSTEM TERMINATION Before installing Power Venter determine location of vent system termination. TOOLS REQUIRED Saber Saw or Cement Drill Drill 1/8 and 1/4 Drill Bits Wood or Masonry Chisel Blade Screwdriver or 1/4 Nut Driver Wire Cutter/Stripper For oil installations do not terminate HS-Series Power Venters on vinyl siding because temperatures can easily exceed F. The SideShot is the only Tjernlund Power Venter recommended for termination on vinyl siding when using oil. NOTE: Termination of a Side Wall Vent System with a device other than the Tjernlund VH1 Series Vent Hood could affect system performance and result in a possible safety hazard. Consult Vent Hood instructions for complete installation details. If possible, locate the Vent Hood on a wall that does not face the direction of prevailing winds. This will diminish the possibility of appliance interruption during periods of extreme winds and prevent oil odors caused by backdrafts. If possible, locate the Vent Hood no closer than 3 feet from an inside corner of an L-shaped structure. CODE REQUIREMENTS Terminate the vent system so that proper minimum clearances are maintained as cited in the latest edition of the National Fuel Gas Code (NFPA # 54) and the latest edition of NFPA #211, or as follows: Not be less than 7 feet above grade when located adjacent to public walk ways. At least 3 feet above any forced air inlet located within 10 feet. At least 4 feet below, 4 feet horizontally from or 1 foot above any door, window or gravity air inlet into any building. At least 12 inches above grade. So that the flue gases are not directed so as to jeopardize people, overheat combustible structures or enter buildings, and Not less than 2 feet from an adjacent building. POWER VENTER INSTALLATION 4
6 POWER VENTER INSTALLATION VERIFY POWER VENTER MODEL SELECTION USING TABLES ON PAGE 1. CODE REQUIREMENTS The Power Venter installation must be done in accordance with the following requirements of the latest Edition of the National Fuel Gas Code (NFPA #54): All portions of the vent system under positive pressure during operation (on the outlet side of Power Venter) shall be designed and installed so as to prevent leakage of flue or vent gases into the building. All appliances must enter the vent system on the inlet side of the Power Venter. Provision shall be made to interlock the appliance(s) to prevent the flow of gas to the main burners when the draft system is not performing so as to satisfy the operating requirements of the equipment for safe performance. See Electrical Wiring section of this manual for details. INSTALLATION RESTRICTIONS DIAGRAM A 1. Power Venter must be installed as close as possible to the termination of the vent system to obtain optimal appliance efficiency and to prevent flue gas leakage, (See Diagram A). 2. The Power Venter may be mounted in any position as long as the shaft of the motor remains horizontal, to prevent motor bearing wear and to ensure proper Fan Proving Switch operation, (See Diagram B). DIAGRAM B 3. The Power Venter housing is single wall. A 6 clearance to combustibles must be maintained for gas and 18 clearance for oil applications, (See Diagram C). If the appliance nameplate specifies a vent connector clearance greater than 6 inches, the greater clearance must be used. Refer to NFPA # 31 for Oil Burning Equipment. DIAGRAM C NOTE: Clearance to combustibles may be reduced. Please refer to Clearance Table VI in NFPA #54 and your local code authority. 4. Vent pipe transitions, where necessary, must be gradually tapered, (See Diagram D). DIAGRAM D 5
7 5. Power Venter to vent pipe connections and all joints on the outlet side of the Power Venter must be sealed with high-temperature silicone sealant or aluminum vent pipe tape to prevent flue gas leakage, (See Diagram E). 6. Oil installations require the use of a barometric draft control. Draft control must be installed between the appliance outlet and the Power Venter inlet, (See Diagram E). Oil installations should use the same diameter pipe on the inlet and discharge side of the Power Venter. 7. Allow for a minimum straight section of pipe equal to 3 times the diameter of the vent pipe being used when installing elbows on the discharge side of the Power Venter. For example, if using 4 pipe, allow for 12 of straight pipe before using an elbow, (See Diagram F). DIAGRAM E DIAGRAM F POWER VENTER MOUNTING 1. Slide the outlet of the Power Venter over the inner sleeve of the Vent Hood and connect them together using a tapered transition fitting if necessary, (See Diagram G). If you are unable to make a direct connection to the Vent Hood, vent pipe may be installed between the Power Venter and Vent Hood. However, all vent pipe connections after the Power Venter must be sealed with high temperature silicone caulk or aluminum vent pipe tape to prevent flue gas leakage, (See Diagram E). 2. To facilitate installation and reduce vibration we have included 2 mounting brackets, 2 rubber isolaters and 2 rubber grommets. One of the brackets may be used temporarily as a third hand while positioning it for permanent installation. 3. When installing the Power Venter for horizontal mount, install one of the brackets to the electrical box using the nut/screw provided. Install the other to the damper rod as shown below. When installing the Power Venter for vertical mount, only one bracket is needed. This bracket should be mounted to the motor as shown below. Temporarily support the Power Venter using wire or a ladder and assemble the mounting brackets, (See Diagram H). DIAGRAM G DIAGRAM H 4. Verify required vent pipe diameter from Power Venter Selection on Page 1. Verify that a full sized barometric control has been installed on appliances not equipped with a draft hood or draft diverter. 5. Install properly sized vent pipe sections from Power Venter inlet to appliance outlet avoiding elbows wherever possible, using only tapered transitions. In most cases a reduction in vent pipe diameter from that of the appliance flue outlet will be necessary. 6. Using four holes as guides, attach vent pipe to Power Venter inlet collar using sheet metal screws. 7. Support vent pipe in accordance with vent pipe manufacturer s instructions. 8. All necessary vent pipe connections after the Power Venter will be under positive pressure during operation. These connections must be sealed with high-temperature silicone sealant or aluminum vent pipe tape supplied by the installer, (See Diagram E). 6
8 FURNACEPOWER VENTER ON INDUCED DRAFT GAS APPLIANCES When installing the Power Venter on induced draft gas appliances, a barometric draft control must be added. The draft control provides pressure relief to neutralize over-drafting and allows a means of draft adjustment for optimum burner efficiency. By adjusting the draft control the installer can obtain the appliance manufacturer s recommended draft setting. Install the vent pipe and draft control as shown in the diagrams below. The draft control should connect to a tee off of the appliance flue outlet. The Power Venter may only be used with appliances capable of being chimney vented. It is not suitable for use on high-efficiency, condensing models. (UPFLOW APPLIANCE) (DOWNFLOW APPLIANCE) 7
9 ELECTRICAL WIRING WIRING RESTRICTIONS 1. All wiring from the Power Venter to the appliance must be appropriate class 1 wiring as follows: Installed in rigid metal conduit, intermediate metal conduit, intermediate metal conduit, rigid non-metallic conduit, electrical metallic tubing, Type MI cable, Type MC cable or be otherwise suitably protected from physical damage. 2. The electrical contact ratings for the diaphragm Fan Proving Switch are as follows: 3 amps (full load) at 120 VAC 28VA Pilot Duty (1.16 amps) at 24 VAC 125 VA Pilot Duty at 120 VAC The Fan Proving Switch and Power Venter are not suitable for use with loads which exceed the above limitations. HSUL OR HST SERIES WIRED AT 24V GAS VALVE: TJERNLUND POWER VENTER SEQUENCE OF OPERATION As the thermostat senses a need for heat, 24V is applied to the Power Venter relay. The 24 volts applied to the relay coil bring in the volt power to the motor. The air movement generated by the Power Venter closes the Fan Proving Switch contacts which allow the thermostat signal to reach the 24 volt gas valve. The Fan Proving Switch actually becomes the burner controller and will allow the appliance to operate only when the thermostat is calling for heat and the Power Venter is operating. DO NOT OPERATE THE APPLI- ANCE WITHOUT THE FAN PROVING SWITCH WIRED INTO THE 24V APPLIANCE CIRCUIT! HSUL OR HST SERIES WIRING TO THERMOSTAT ON SINGLE ZONE FURNACE/BOILER INSTALLATIONS As the thermostat senses a need for heat, 24V is applied to the Power Venter relay. The 24 volts applied to the relay coil bring in the volt power to the motor. The air movement generated by the Power Venter closes the Fan Proving Switch contacts which allow the thermostat signal to reach W on the 24 volt burner control. The Fan Proving Switch actually becomes the burner controller and will allow the appliance to operate only when the thermostat is calling for heat and the Power Venter is operating. DO NOT OPER- ATE THE APPLIANCE WITHOUT THE FAN PROVING SWITCH WIRED INTO THE 24V APPLIANCE CIRCUIT! HS SERIES WIRED AT V GAS VALVE OR BURNER MOTOR: As the thermostat senses a need for heat, V is applied to the Power Venter motor. The air movement generated by the Power Venter closes the Fan Proving Switch contacts which allow V to be applied to the gas valve or burner motor. The Fan Proving Switch actually becomes the burner controller and will allow the appliance to operate only when the thermostat is calling for heat and the Power Venter is operating. DO NOT OPERATE THE APPLIANCE WITHOUT THE FAN PROVING SWITCH WIRED INTO THE V APPLIANCE CIRCUIT! HST SERIES WIRED TO OIL BURNER: Control signal from thermostat, aquastat or primary control is intercepted and routed to the ORANGE of Relay/Timer and BLUE from HST Fan Prover with either 24 VAC or 120 VAC. The Relay/Timer receives current and HST motor is energized. After draft is established within the HST, the Fan Proving Switch closes completing the circuit allowing burner to fire. The ORANGE wire from Relay/Timer can accept either a 24 VAC or 120 VAC control signal. For most furnace applications it may be easier to interlock with the 24 VAC thermostat circuit. For most boiler applications it may be easiest to interlock with the 120 VAC primary control circuit to the burner motor. For boiler applications with solid state primary controls it is recommended that the interlock be made between the aquastat and the primary control to avoid the need for a field installed isolation relay. This relay is necessary to eliminate false triggering of the HST by circuit checks that are common with solid state controls. Choose the interlock method that best fits your application. DO NOT OPERATE THE BURNER WITHOUT THE FAN PROVING SWITCH WIRED INTO THE BURNER CIRCUIT! DISCONNECT VAC POWER TO THE APPLIANCE BEFORE PROCEEDING WITH POWER VENTER WIRING. THE POWER MAY BE DISCONNECTED BY TRIPPING THE CIRCUIT BREAKER OR REMOVING THE FUSE PROTECTING THE APPLIANCE. ELECTRICAL CONDUIT AND 24 VAC WIRING MUST BE ROUTED AWAY FROM ANY HOT SURFACES. USE ADEQUATE CON- DUIT SUPPORTS WHERE NECESSARY. ALL WIRING MUST COMPLY WITH APPLICABLE CODES AND ORDINANCES. ALL VAC WIRING MUST USE RIGID OR SEMI-RIGID METAL CONDUIT WITH 18 AWG, 300 VAC, 90 DEGREE C-RATED COP- PER WIRE. NOTE: The following wiring diagrams are designed to satisfy most installations. Should your installation be different from those shown in these instructions, please contact the Tjernlund Technical Service Department for assistance at , 7:30-4:30 CST. 8
10 9
11 10
12 HSUL SERIES CONNECTED WITH 24V THERMOSTAT ON SINGLE ZONE GAS EQUIPMENT HST SERIES CONNECTED WITH 24V THERMOSTAT ON SINGLE ZONE GAS OR OIL EQUIPMENT NOTE: Power Venter may operate independently of burner circuit when power is initially supplied to L1 and L2 connections of the Relay/Timer. If the Power Venter continues to operate for more than 10 minutes without a call for heat, verify that wiring is in accordance with proper diagram. NOTE: This wiring diagram may not be compatible with certain set-back thermostats. If the Power Venter runs without a call for heat, (after initial post-purge time delay from 1-10 minutes), an isolation relay will have to be added to isolate the 4 & 5 coil inputs on Relay/Timer. See diagram below for wiring with isolation relay. HST SERIES CONNECTED WITH SET BACK THERMOSTAT AND ISOLATION RELAY (NECESSARY IF HST CYCLES ERRATICALLY) NOTE: Power Venter may operate independently of burner circuit when power is initially supplied to L1 and L2 connections of the Relay/Timer. If the Power Venter continues to operate for more than 10 minutes without a call for heat, verify that wiring is in accordance with proper diagram. 11
13 HS SERIES CONNECTED TO ANY V BURNER MOTOR OR GAS VALVE (BURNER MOTOR OR GAS VALVE LESS THAN VAC) HSUL SERIES CONNECTED TO A 24V GAS HONEYWELL SMART VALVE (SV SV9600 SERIES) HST SERIES CONNECTED TO AN R8184G WITH THE APPLIANCE BURNER MOTOR LESS THAN VAC NOTE: Power Venter may operate independently of burner circuit when power is initially supplied to L1 and L2 connections of the Relay/Timer. If the Power Venter continues to operate for more than 10 minutes without a call for heat, verify that wiring is in accordance with proper diagram. NOTES: The Power Venter is usually interlocked with the primary control of the appliance. Wire all other furnace/boiler controls as normally done when conventional venting before continuing. Disconnect power from the appliance before attempting to interlock Power Venter. 1. Disconnect the BLACK burner motor wire from the ORANGE wire of the R8184G. 2. Reconnect the BLACK burner motor wire to the YELLOW wire in the Power Venter electrical box. 3. Connect the ORANGE wire from R8184G to the ORANGE and BLUE wires in Power Venter electrical box. NOTE: Ignition transformer will continue to be attached to the ORANGE of the cad cell relay. 4. Connect the WHITE/BROWN wire in Power Venter electrical box to the WHITE wire on the burner motor. 5. Connect the BLACK wire in Power Venter to L1. 6. Connect both WHITE wires in the Power Venter to L2. 12
14 HST SERIES CONNECTED TO AN R8184G WITH THE APPLIANCE BURNER MOTOR GREATER THAN 3 AMPS AND LESS THAN VAC NOTE: Power Venter may operate independently of burner circuit when power is initially supplied to L1 and L2 connections of the Relay/Timer. If the Power Venter continues to operate for more than 10 minutes without a call for heat, verify that wiring is in accordance with proper diagram. NOTES: The Power Venter is usually interlocked with the primary control of the appliance. Wire all other furnace/boiler controls as normally done when conventional venting before continuing. Disconnect power from the appliance before attempting to interlock the Power Venter. 1. Disconnect the BLACK burner motor wire from the ORANGE wire of the R8184G Cad Cell Relay. 2. Connect the BLACK burner motor wire to terminal 3 of the installer supplied R4222B1082 relay. 3. Connect the ORANGE wire of the R8184G to the ORANGE and BLUE wires in the Power Venter and terminal #1 on R4222B Connect the YELLOW wire from the Power Venter to one side of coil on installer supplied R4222B1082 relay. 5. Connect Common of R4222B1082 coil to L2. 6. Connect the WHITE and WHITE/BROWN wire in the Power Venter to L2. 7. Connect the BLACK wire in the Power Venter to L1. HST WIRED WITH AQUASTAT CONTROLLED OIL BURNERS 13
15 HST CONNECTED TO A CARLIN PRIMARY CONTROL SAFETY INTERLOCK / COMBUSTION AIR TEST The Power Venter Fan Proving Switch is designed to disable the appliance gas valve or burner motor upon Power Venter failure only! It is not designed and cannot replace, regular vent system inspection, appliance servicing and combustion testing. 1. Close all doors and windows of the building. If the appliance is installed in a utility room or closet, close the entrance door to this room. Close fireplace dampers. DIAGRAM I 2. Turn on clothes dryer and all exhaust fans such as range hoods, bathroom exhausts and whole house fans to maximum speeds. Do not operate a fan used strictly for Summer exhausting. 3. Following the appliance manufacturer s instructions, place the appliance in operation, set thermostat for continuous operation. PROPER DRAFT ESTABLISHED PROPER DRAFT ESTABLISHED GAS After allowing appliances to operate for five minutes, test for spillage at the draft hood relief opening (draft diverter or draft control). Approved method follows (ANSI Z2331, section 8.6): CHECKING THE DRAFT. Vent connected gas utilization equipment shall be operated for several minutes and checked to see that the combustion products are going up the chimney or gas vent properly, by passing a lighted match or taper around the edge of the relief opening of the draft hood. If not, the combustion products will tend to extinguish this flame. If the combustion products are escaping from the relief opening of the draft hood, the equipment shall not operate until proper adjustments or repairs are made to provide adequate draft through the chimney or gas vent., (See Diagram I). If the draw of the flame or smoke appears to be excessive, make necessary adjustments to barometric draft control (if needed) or follow the Power Venter Air Flow Damper Adjustment procedure outlined on page 15. OIL Make necessary adjustments to the primary air intake and barometric draft control to comply with the over-fire draft requirements of the appliance. In most cases, the over-fire draft should be in a range of -.02 to -.04 W.C. If adjustments to the primary air intake and barometric draft control do not provide the required over-fire draft, the Power Venter draft adjustment must be repositioned accordingly. Measure over-fire draft after repositioning Power Venter draft adjustment, (See Diagram J, Page 15). 4. Next, turn on all other fuel-burning appliances within the same room so they will operate at their full input. Repeat Step 3 above, checking the draft on each appliance. 14
16 POWER VENTER AIR FLOW DAMPER ADJUSTMENT The Air Flow Damper Adjustment on the Power Venter is factory set for maximum air flow. Operating a properly sized Power Venter at its maximum setting will assure that combustion gases are safely removed to the outside. If the Power Venter has excess venting capacity than what is required for this application, operating the Power Venter with the air-flow adjustment at the maximum setting may draw more dilution air than necessary. The Air Flow Damper Adjustment may be set by use of a combustion analyzer, inclined manometer or draft gauge. Alternatively, the damper adjustment can be set using a smoke candle or taper, as follows: 1. With all exhaust fans operating, air inlets closed and all appliances firing (as instructed above), hold a lighted match or taper around the edge of the relief opening of the draft hood(s) or barometric draft control, (See Diagram I). 2. Set Air Flow Adjustment by loosening locknut and turning damper rod handle. CAUTION: HANDLE MAY BE HOT, use pliers to move handle. Position of rod handle indicates the position of Air Flow Adjustment inside housing, (See Diagram J). 3. Using pliers, move handle towards minimum draft setting until spillage is detected at draft hood relief opening, then re-open Air Flow Adjustment just enough to eliminate spillage. 4. Lock Air Flow Adjustment at desired setting by tightening locknut. 5. Return doors, windows, exhaust fans, fireplace dampers and appliances to their previous conditions of use. COMBUSTION AIR DIAGRAM J Adequate combustion air is vital for proper combustion and for safe venting. Likewise, for proper Power Venter performance, adequate combustion air must be available to the appliance. Many installers assume adequate combustion air is present, especially in older homes. In some cases this is a false assumption, because many older homes have been made "tight" due to weatherization. Size the combustion air opening(s) into the appliance room as outlined local or national codes. Tjernlund s IN-FORCER TM Combustion Air Intake Systems provide a convenient interlocked way to provide combustion air to the equipment room. When installing a Power Venter it is not necessary to supply any more combustion air than normally required when conventional venting. Common symptoms of inadequate combustion air include: Fan Proving Switch short cycling, odor present at end of burner cycle, outside air enters the structure through the Power Venter during appliance off cycle. 1. Disrupt VAC power to the Power Venter. 2. Loosen the two screws and remove junction box cover. HST SERIES POST PURGE TIMER ADJUSTMENT 3. The post purge Relay/Timer is marked adjustable delay control. The adjustment is made by turning the small slotted screw. Turn it counter clockwise to increase the delay, clockwise to decrease the delay. Nominal adjustment range is 1 to 10 minutes. NOTE: Do not overturn adjustment on Relay/Timer. This will damage Relay/Timer and void warranty. MAINTENANCE 1. Oil motor every six months with 2 drops of S.A.E. #20. The oil ports are located on the top ends of the motor. Magnetek motors on the HSJ and HS1 Series do not need to be oiled. 2. The end-user must semiannually inspect the Vent Hood and vent pipe for blockage, corrosion and leaks. 3. A vent system inspection must be performed annually by a qualified service agency. The inspection should include the operation circuit check, safety interlock test, combustion air test and a visual inspection of the complete vent system for corrosion, blockage or leaks. Any corrosion, blockage or leaks detected must be repaired or replaced immediately. TROUBLESHOOTING The following guide is intended to be used if a problem occurs during the use of the Power Venter. At several steps throughout the guide you will be required to measure Volts with a voltmeter. Extreme caution must be exercised to prevent injury. If you are unable to determine the defective part with the use of this guide, call your Tjernlund distributor or Tjernlund Products direct at for further assistance. 15
17 SYMPTOM 1: POWER VENTER DOES NOT RUN DURING CALL FOR HEAT (HSUL & HST SERIES ON GAS OR HST SERIES ON OIL WIRED WITH SINGLE ZONE 24V THERMOSTAT) Step 1 Activate thermostat to call for heat. Check for 24V across terminals 4 and 5 of the Relay/Timer (HST) or the coil of Ice Cube Relay with the BLUE and ORANGE leads attached (HSUL). 24Volts Not Present Step 1.1 Interlocked directly with gas valve Verify 24V across appliance control such as (Aquastat B1/B2), (Intermittent Ignition Module MV - MV/PV), or (Standing Pilot TH - Hot & TR - Common) during call for heat. Interlocked with thermostat at furnace Verify 24V across R & C on furnace terminal strip. 24V Step 1.2 Interlocked directly with gas valve Check for loose connections between appliance and Power Venter. Interlocked with thermostat at furnace Contact T-Stat manufacturer for further assistance. 24V No Step 2 Remove V power source to the Power Venter. Remove the two BLACK leads from the Relay and connect them together. Reestablish V. Result: Power Venter runs continuously. No Solution: Contact appliance manufacturer for further assistance. Solution: Replace Power Venter Motor. Part # s HSJ HS HS Solution: Replace Relay/Timer (HST) Part # or Ice Cube Relay (HSUL) Part # SYMPTOM 2: POWER VENTER RUNS CONTINUOUSLY / ERRATICALLY (HSUL & HST SERIES ON GAS OR HST SERIES ON OIL WIRED WITH SINGLE ZONE 24V THERMOSTAT) Step 1. Confirm that thermostat is not calling for heat. No call for heat Step 2. With the Power Venter running, remove the WHITE/BROWN wire on Relay/Timer terminal #5 (HST) or the ORANGE wire from Ice Cube Relay (HSUL). Result: Power Venter should shut off within 10 minutes (HST). Power Venter should shut off immediately for HSUL. No Solution: Replace the Relay/Timer (HST) Part # or Ice Cube Relay (HSUL) Part # Step 3. Reinstall the WHITE/BROWN wire on Relay/Timer terminal #5 (HST) or the ORANGE wire from Ice Cube Relay (HSUL). Verify thermostat is not calling for heat. Interlocked directly with gas valve Check for 24V across appliance control such as (Aquastat B1/B2), (Intermittent Ignition Module MV - MV/PV) or (Standing Pilot TH - Hot & TR - Common). Interlocked with thermostat at appliance Check for voltage across W & C at thermostat. If voltage under 24V is present and the model is a HST with a set-back thermostat, a 24V isolation relay will have to be installed to isolate the 4 & 5 coil inputs on Relay/Timer. Wiring diagram is included on Page 12 of these instructions. 24 Volts present Solution: Contact the appliance manufacturer for further assistance. 24 Volts not present Contact Tjernlund Products, Inc. for additional assistance. 16
18 SYMPTOM 3: POWER VENTER RUNS BUT APPLIANCE DOESN T (HSUL & HST SERIES ON GAS OR HST SERIES ON OIL WIRED WITH SINGLE ZONE 24V THERMOSTAT) Step 1. Confirm that thermostat is not calling for heat. No call for heat Step 2. Remove the BLUE and YELLOW wires from Power Venter Proving Switch. Activate thermostat to call for heat. With Power Venter running, check for continuity across the COM and N/O terminals of Fan Proving Switch. Result: Contacts on switch should be closed. No Step 2.1 Examine Fan Prover sensing tube for kinks, misalignment or blockage. Sensing tube should be at an approx. 90 degree angle to wheel. Bad Tube Contact your wholesaler for replacement tube. Tube Ok Step 3. Replace BLUE to COM and YELLOW to N/O on Fan Proving Switch. Confirm that leads from Fan Prover are connected as follows: Interlocked directly with gas valve YELLOW wire is connected to the TH (HOT) on gas valve and BLUE is connected to appliance control (Aquastat B1), (Intermittent Ignition Module MV) or (Standing Pilot TH - Hot ). Step 2.2 Examine Power Venter wheel for particulate build-up. Wheel Clean Wheel Dirty Clean Power Venter Wheel. Interlocked with thermostat at appliance YELLOW wire connected to W on furnace terminal strip and BLUE is connected to W from T-Stat. Step 2.3 Confirm adequate combustion air is present in appliance location, Power Venter is sized properly for application and vent runs do not exceed maximum length. Make sure vent isn t blocked. No Supply adequate combustion air, proper Power Venter or reduce vent pipe length. Contact Tjernlund Products, Inc. for additional assistance. Solution: Replace Fan Proving Switch Part # s HSJ HS HS SYMPTOM 1: POWER VENTER RUNS BUT BURNER DOES NOT FIRE (HST SERIES ON OIL WIRED WITH R8184 SERIES PRIMARY CONTROL) Step1. Activate appliance to call for ignition. At this time the Power Venter should be running. Remove the BLUE and YELLOW leads on Fan Prover. Check for continuity across the N.O. and COM terminals of the Fan Prover. Result: Circuit should be closed NO Step 1.1 Examine the Fan Prover Sensing Tube for kinks, mis-alignment or blockage. NO Solution: Contact your wholesaler for a replacement Fan Prover Sensing Tube. Step 1.2 Examine blower wheel for particulate buildup or a closed discharge damper. Solution: Clean or replace blower wheel or open discharge damper. NO Step 2. Confirm that YELLOW wire from Fan Prover is connected to the BLACK of the burner motor. Step 1.3 Confirm that adequate combustion air is present in appliance location and Power Venter is sized properly for the application. Make sure vent isn t blocked. Solution: Contact Tjernlund Products, Inc. for further assistance. Step 3. Contact Tjernlund Products, Inc. for additional assistance. 17
19 SYMPTOM 2: POWER VENTER DOES NOT RUN DURING CALL FOR HEAT (HST SERIES ON OIL WIRED WITH R8184 SERIES PRIMARY CONTROL) Step 1. Activate appliance to call for ignition. Check for volts across the #4 and #5 terminals on Relay/Timer. Result: Measure volts. No Step 1.1 With appliance calling for ignition, check for volts across the ORANGE and WHITE leads of Cad Cell Relay. Result: Measure volts. Solution: Contact Tjernlund Products for further assistance. No Step 1.2 Solution: Check the Reset button on primary control or contact appliance manufacturer for further assistance. Step 2. With volts present at terminals #4 and #5 of Relay/Timer, check for volts across the BLK MOTOR and L2 terminals on Relay/Timer Result: Measure volts No Step 2.1 Solution: Replace Timer/Relay. Part # Step 3. CAUTION: Before attempting the following procedure remove the volt source to the Power Venter. Remove the two BLACK leads from Relay/Timer and connect them together. Reestablish the volt source to the Power Venter. Result: Power Venter runs continuously. No Step 3.1 Solution: Replace the Power Venter motor. Part # s HST-J HST HST Step 4. Contact Tjernlund Products, Inc. for additional assistance. HOW TO OBTAIN SERVICE ASSISTANCE 1. If you have any questions about your Power Venter or if it requires adjustment, repair or routine maintenance, we suggest that you contact your installer, contractor or service agency. 2. If you require technical information contact Tjernlund Products, Inc. at or When contacting Tjernlund Products, Inc., please have the following information available: 1. Model number of the Power Venter 2. Name and address of installer and service agency 3. Date of original installation and dates any service work was performed 4. Details of the problem LIMITED PARTS WARRANTY AND CLAIM PROCEDURE Tjernlund Products, Inc. warrants the components of its products for one year from date of installation. This warranty covers defects in material and workmanship. This warranty does not cover normal maintenance, transportation or installation charges for replacement parts or any other service calls or repairs. Products that are tampered with, damaged or defective due to malfunctioning appliances are not covered under this warranty. This warranty DOES NOT cover the complete Power Venter if it is operative, except for the defective part. Tjernlund Products, Inc. will issue credit or provide a free part to replace one that becomes defective during the one year warranty period. If the part is over 18 months old, proof of date of the installation in the form of the contractor sales/installation receipt is necessary to prove the unit has been in service for under one year. All receipts should include the date code of the Power Venter to ensure that the defective component corresponds with the complete unit. This will help preclude possible credit refusal. 18
20 Please direct any contractor who wants to make a warranty claim to follow these instructions: 1.) Follow troubleshooting guide to determine defective component. If unable to determine faulty component, contact your Tjernlund distributor or Tjernlund Products Technical Customer Service Department at for troubleshooting assistance. 2.) After the faulty component is determined, return it to your Tjernlund distributor for replacement. Please include Power Venter date code component was taken from. The date code is located on the electrical box cover plate. If Power Venter date code is older than 18 months you will need to provide a copy of the original installation receipt to your distributor. Credit or replacement will only be issued to a Tjernlund distributor after the defective part has been returned prepaid to Tjernlund. REPLACEMENT PARTS MODEL HSUL-J PART NUMBER DESCRIPTION MOTOR KIT WHEEL KIT FAN PROVER KIT RELAY KIT MODEL HST-J PART NUMBER DESCRIPTION MOTOR KIT WHEEL KIT FAN PROVER KIT RELAY/TIMER MODEL HS-J PART NUMBER DESCRIPTION MOTOR KIT WHEEL KIT FAN PROVER KIT MODEL HSUL-1 PART NUMBER DESCRIPTION MOTOR KIT WHEEL KIT FAN PROVER KIT RELAY KIT MODEL HST-1 PART NUMBER DESCRIPTION MOTOR KIT WHEEL KIT FAN PROVER KIT RELAY/TIMER MODEL HS-1 PART NUMBER DESCRIPTION MOTOR KIT WHEEL KIT FAN PROVER KIT MODEL HSUL-2 PART NUMBER DESCRIPTION MOTOR KIT W/WHEEL WHEEL KIT 3/8 BORE FAN PROVER KIT RELAY KIT MODEL HST-2 PART NUMBER DESCRIPTION MOTOR KIT W/WHEEL WHEEL KIT 3/8 BORE FAN PROVER KIT RELAY/TIMER MODEL HS-2 PART NUMBER DESCRIPTION MOTOR KIT W/WHEEL WHEEL KIT 3/8 BORE FAN PROVER KIT WHAT IS NOT COVERED Product installed contrary to our installation instructions Product that has been altered, neglected or misused Product that has been wired incorrectly Product that has been damaged by a malfunctioning or mistuned burner Any freight charges related to the return of the defective part Any labor charges related to evaluating and replacing the defective part TJERNLUND ONE YEAR LIMITED WARRANTY Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of (1) year from the date of original purchase or delivery to the original purchaser, whichever is earlier. Remedies under this warranty are limited to repairing or replacing, at our option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc. at the address listed below, postage prepaid. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF, AND TJERNLUND PRODUCTS, INC. EXPRESSLY DISCLAIMS LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAM- AGES ARISING FROM THE USE OF THIS PRODUCT. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY LIABILITY ADDITIONAL TO THOSE SET FORTH IN THIS LIMITED WARRANTY. IMPLIED WARRANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIM- ITED WARRANTY. Some states do not allow limitation on how long an implied warranty lasts, so that limitation may not apply to you. In addition, some states do not allow the exclusion or limitation of incidental or consequential damages, so that above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which may vary from State to State. Send all inquiries regarding warranty work to Tjernlund Products, Inc th Street, White Bear Lake, MN Phone (651) (800) Fax (651) [email protected] 19
MODEL MAC-3 MULTIPLE APPLIANCE CONTROL
TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com REV. A 5/99 MODEL MAC-3 MULTIPLE APPLIANCE
MODELS WATER HEATER VENT PACKAGE. For Natural Gas or LP
TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com Patented MODELS VP-2 For Millivolt
AUTO-DRAFT INDUCER INSTALLATION INSTRUCTIONS MODELS D-3 XL
REV. A 7/00 TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com AUTO-DRAFT INDUCER INSTALLATION
CONVERSION TIPS FOR OLD HSUL & HST SERIES POWER VENTERS IMPORTANT!!! UC1 BOARD VERSION X.06 UPDATES
TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com CONVERSION TIPS FOR OLD HSUL & HST
CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS
CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS WARNING Improper installation, adjustment, alteration, service, or maintenance of this product can cause
ASX7-4-IOM-7 J30-08579
INSTALLATION INSTRUCTIONS 4" COMBUSTION AIR INLET KIT TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS UNIT CONVERSION & CATEGORY III VENTING FOR SEPARATED COMBUSTION For 30,000 to 75,000 BTU/HR SUPPLEMENT
MODEL FAI4 FRESH AIR INTAKE KIT
TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com MODEL FAI4 FRESH AIR INTAKE KIT INCLUDES
Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL
Propane Conversion Kit Supersedes: 145.25-IOM2 (708) Form 145.25-IOM2 (908) PROPANE CONVERSION KIT INSTALLATION MANUAL "LPKIT " - PROPANE CONVERSION KIT Kits are available for field conversion from natural
Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting
ING THE WATER HEATER The purpose of venting a gas or oil-fired water heater is to completely remove all products of combustion and to vent gasses to the outside air without condensation in the vent or
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
DBF 4XL Dryer Booster Fans
Installation and Operation Manual Item #: 401315 Rev Date: 121514 DBF 4XL Dryer Booster Fans DBF4XL Kit Includes: Dryer Booster Fan, 1 pc Fan Mounting Bracket and Hardware, 1 pc Wall Label (Mount on wasll
PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL
PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL Boiler Manual A. INSTALLING EXHAUST VENT AND INTAKE AIR VENT B. GENERAL n DANGER The Elite Heating Boiler must be vented as detailed in this section.
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
G670 Intermittent Pilot Ignition Controls
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin Issue Date 0300 Intermittent Pilot Ignition Controls Figure 1: Intermittent Pilot Ignition Control
American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems
American Fireglass Outdoor Fire pit kit information General instructions/warnings for outdoor gas pan and burner systems We strongly recommend that our burner products be installed by a licensed and certified
Installation Instructions
520 Installation Instructions Thank you very much for purchasing PIAA product. Please read this entire manual before installation and use of this product. For Installers Please give this Installation Manual
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00
RESIDENTIAL HEATING OIL SERVICE CONTRACT This service contract covers all routine service and maintenance of your residential oil fired furnace or boiler. In addition this contract covers all service calls
Fossil fuel heating equipment
Fossil fuel heating equipment principles and troubleshooting techniques Application Note This application note was written to provide you with an understanding of the basic principles of fossil fuel heating
READ AND SAVE THESE INSTRUCTIONS
AUTOMATIC WITH To register this product visit: www.broan.com MODELS MD6T MD8T MD10T READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY Page 1 WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS
OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS LiteAide HE-100B HE-100BW HE-112 HE-112W HE-117 HE-117W HE-117-2B OWNER'S MANUAL FLOOD LAMPS (BULBS) Your
Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.
INSTALLATION, OPERATING AND SERVICE MANUAL FOR EASY RADIANT WORKS HEATWAVE MODEL GH-25-40 GAS FIRED, VENTED INFRARED TUBE HEATER FOR RESIDENTIAL & COMMERCIAL / INDUSTRIAL APPLICATIONS. For Your Safety
TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation
GTRDD SERIES HEATLESS DRYER INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS SECTION 1 General Information: Pg 2 Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation
PLP - TERMS AND CONDITIONS
PLP - TERMS AND CONDITIONS 2014-2015 Philadelphia Gas Works Residential Parts & Labor Plan Contract This Residential Parts & Labor Plan Contract (this Plan ) is available to customers of the Philadelphia
PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167
PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 87976466 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
Not required for most applications Not required for most applications High pressure (12-803 provided) High pressure (12-803 provided)
ELECTRIC FUEL PUMPS P/N 12-801-1, 712-801-1, 12-802-1, 712-802-1, 12-815-1, & 712-815-1 FUEL PRESSURE REGULATORS P/N 12-803, 12-501, 12-804, 12-500, & 15812NOS Installation Instructions THESE INSTRUCTIONS
OTF Oil Fired Pool Heater
OTF Oil Fired Pool Heater Installation Operation Maintenance Manual Service Policy 722010 Congratulations on the purchase of your new pool heater. In order to maintain peak performance of your pool heater
Ceiling Mount Air Handler Manual
www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty
SL280UHV SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2008-36 TSG-PRESTIGE Date revised: 12/6/10
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE Date revised: 12/6/10 2008-36 TSG-PRESTIGE Table of Contents INTRODUCTION Page 1-2 SERVICING TIPS AND INSTRUCTIONS Page 3-4
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Evaluate, Clean, and Tune Guidance
Evaluate, Clean, and Tune Guidance The Evaluate, Clean and Tune (ECT) process serves three essential purposes in the Weatherization Assistance Program (WAP). The first is to evaluate the existing system
Utility Distribution Systems
Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date
THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER
THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended Type
NAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html TECHNICAL SERVICE DEPARTMENT Effective October 2007, we transitioned to the White Rodgers (Intelli-Vent TM )Thermostat Control for
GAS SAFETY PRECAUTIONS
GAS SAFETY PRECAUTIONS Instructions on what to do when a user smells gas can be obtained from the local gas supplier. These instructions must be posted in a prominent location where the unit is to be operated.
GeniSys 12V. Model 7556. Description / Applications. Advanced 12 Vdc Burner Control
PARTS & ACCESSORIES GeniSys 12V Model 7556 Advanced 12 Vdc Burner Control Description / Applications The Beckett GeniSys TM 12V Advanced Burner Control is a 12 Vdc primary safety control for oil burners
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.
QUIET-ONE Environmental Products 2000 Kickspace Heater Series Models: KS 2004, KS 2006 KS 2008, KS 2010 INSTALLATION OPERATING MAINTENANCE Please read these instructions thoroughly before beginning your
LOBOY 16 AIR CONDITIONERS
INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8
WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:
Revision Level: 01 Revision Date: 07/07/2011 Please read all instructions carefully to help ensure a correct and SAFE installation of your Second Wind Ultraviolet Germicidal Air Purifier. Failure to do
INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS
INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS Installation and service must be provided by a qualified installer, service agency or gas supplier Grand Canyon Gas Logs, logs are made
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html APPLY POWER TO APPLIANCE FIELD WIRING CORRECT? DPLAY ERROR CODE 1 OR 2 Intelli-Vent TM Sequence of Operation REQUEST FOR HEAT PRESENT?
WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler
WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler Installation Operation Maintenance The WMSLW/WMBLW series is designed for installation in a closet, utility
WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL
WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL CAUTION: This system is not for use with antenna in raised position while
T-Series Air Conditioner T62 Model
INSTRUCTION MANUAL T-Series Air Conditioner T62 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board. This Troubleshooting Guide covers the electric coolant valve and control
Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.
*00151* FEATURES Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate. Silicon diodes with inherent surge protection operated at a conservative
3 IN 1 BATHROOM HEATER
3 IN 1 BATHROOM HEATER MODEL NO.: A515 - SH MINI FUNCTION: HEATER, EXHAUST FAN AND LIGHT Dear customers, Thank you for selecting the AUPU 3 in 1 Bathroom Heater. Please read all instructions before commencing
Part I - Installation
400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read
Electric Water Heater
Electric Water Heater Operation and Installation Manual (LIMITED WARRANTY AND TANK REPLACEMENT POLICY) The following information should be noted at time of installation and retained for future reference.
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
Installation Operation & Maintenance Manual
www.montigo.com Operation & Maintenance Manual Check local codes and read all instructions prior to installation. EDVPV BF-Series Wall SS Power Gas Fireplace Vent System EDVPV47 EDVPV58 Warning: Improper
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL Service Information If service or parts are required, contact the nearest Norcold Service Center. To find an authorized Norcold Service Center
Single Phase Soft Starter
Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................
Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N 265-47200-00
Instructions for: TTW 1 Universal Service Kit P/N 265-47200-00 (To be performed ONLY by qualified service providers) The Blowers on the Following Water Heaters are Serviced by This Kit: MITW -10 Series
Fuels Safety Program FS- 072-06 7 DIRECTOR S PUBLIC SAFETY ORDER
Ref. No.: Rev. No.: Fuels Safety Program FS- 072-06 7 DIRECTOR S PUBLIC SAFETY ORDER Date: January 13, 2006 IN THE MATTER OF: THE TECHNICAL STANDARDS AND SAFETY ACT, 2000, S.O. 2000, c. 16 - and - ONTARIO
T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200
INSTRUCTION MANUAL FOR: T15 AIR CONDITIONER McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleanthermal.com INSTRUCTION MANUAL TABLE OF CONTENTS
Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION
Chromalox Installation, Operation RENEWAL PARTS IDENTIFICATION Portable Industrial Unit Blower Air Type DRA and DIVISION SALES REFERENCE DATE SECTION (Supersedes P-) PF-) NOVEMBER, 00 DRA PF- -0-00 Specifications
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
Trouble Shooting. Pump
Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft
Installation Instructions
VentilAire IV Whole-House Fresh Air Supply System Installation Instructions 914228 Flat Roof Kit 914229 Sloped Roof Kit 5" x 11' Class I Insulated Flexible Duct Plastic Clamps (2) Metal Clamps (2) Ceiling
Model 7586. Description / Applications. Intermittent Pilot Gas Ignition Control
PARTS & ACCESSORIES Model 7586 Intermittent Pilot Gas Ignition Control Description / Applications The Beckett GeniSys Intermittent Pilot Gas Ignition Control is a 24 Vac gas ignition and safety control.
NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.
INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS PROPANE GAS ADEQUATE FIREPLACE VENTILATION IS REQUIRED FOR SAFETY. GAS LOGS MUST BE INSTALLED BY PERSONNEL QUALIFIED FOR INSTALLING GAS APPLIANCES.
UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual
UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to
IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590. Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580
Any Queries Call : 08000 23 23 23 Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590 Rapide Inline Ceiling Extractor Fan, White Fascia Illuminated 41800040670 Rapide Inline Ceiling Extractor
INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)
CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
Diagnostics for Mobile Homes: HVAC
Diagnostics for Mobile Homes: HVAC Adam Harris NYSWDA Wade Thompson - IWTC Objectives Identify different types of HVAC used in mobile homes Provide an overview of duct systems Demonstrate various tests
INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST
INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST MODEL CHCRV-5 For Use with Bard CH Series 3, 4 & 5 Ton 2-Stage Wall Mount Heat Pumps AND W38H, W43H, W49H and W61H Single Stage Wall Mount
TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT ALPKT7- INSTALLATION INSTRUCTIONS PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements... INSTALLATION INSTRUCTIONS...
TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER
TWIN EAGLES, INC. Defining the Art of Outdoor Cooking TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER OWNER S MANUAL MODEL TEEH-1512 TEEH-2524 TEEH-3524 NEED ASSISTANCE? PLEASE CALL: (562) 802-3488 This
Gas-Fired, Residential Storage Type Water Heaters
Consulting, Resource, Education, Training, and Support Services for Home Inspectors A candle loses no light when it lights another candle. Gas-Fired, Residential Storage Type Water Heaters Most inspectors
12-Volt Negative Ground Installation Instructions
12-Volt Negative Ground Installation Instructions For Part Number: 1141, 1164, 1165, 1181 CAUTION!!! Before installing, please read the following important information... 1. The Ignitor is designed for
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity
For Models #6-5001, #6-7501, #10-7501 & #10-12K1
EmerGen Switch Manual Transfer Switch Manufactured by CONNECTICUT ELECTRIC SWITCH MFG. CO. 1-800-730-2557 OWNER S MANUAL & INSTALLATION INSTRUCTIONS For Models #6-5001, #6-7501, #10-7501 & #10-12K1 PLEASE
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
AT&T. PARTNER Plus Door Phone. Installation and Operation Manual
AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a
Installation and Operation Guide for PD5100 Automatic Transfer Switch
Installation and Operation Guide for PD5100 Automatic Transfer Switch Member P r o gr e ssive Dynamics, Inc. 507 Industrial Rd Marshall, MI 49068 www.progressivedyn.com 2012 Progressive Dynamics, Inc.
USER S INFORMATION MANUAL
USER S INFORMATION MANUAL UPFLOW, DOWNFLOW, UPFLOW/HORIZONTAL & HORIZONTAL ONLY INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this
SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND
Honeywell Electronic Ignition Troubleshooting Tech Tip April 2007 The Honeywell S8610H Intermittent Pilot Module provides the ignition sequencing, pilot spark, pilot flame monitoring, Pilot Valve (PV)
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
12V Portable Diaphragm Compressor Operating and Maintenance Instructions
12V Portable Diaphragm Compressor Operating and Maintenance Instructions (Part No. DC2) Part No. Serial Number Date Purchased Table of Contents Page Safety Messages...2 Guidelines for Product Use...2 Operation
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13
CONTROL PANEL INSTALLATION INSTRUCTIONS Single Phase Simplex Page 2-7 3-Phase Simplex Page 8-13 Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions
37E73A-903 & 906 INTELLI-VENT
37E73A-903 & 906 INTELLI-VENT Water Heater Thermostat Control Installation Instructions For Natural Gas Only Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER
INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER Installation and service must be performed by a qualified service installer, service agency or the gas supplier. Oil Gas/Oil