Description. Safety Guidelines. Specifications. Installation Site. 2 HP - 5 HP Scroll Enclosure Air Compressors

Size: px
Start display at page:

Download "Description. Safety Guidelines. Specifications. Installation Site. 2 HP - 5 HP Scroll Enclosure Air Compressors"

Transcription

1 PREVENT TANK CORROSION kpa pi HP - 5 HP Scroll Encloure Air Compreor Pleae read and ave thee intruction. Read carefully before attempting to aemble, intall, operate or maintain the product decribed. Protect yourelf and other by oberving all afety information. Failure to comply with intruction could reult in peronal injury and/or property damage! Retain intruction for future reference. Decription General The Powerex Oille Rotary Scroll Air Compreor ha advanced croll compreor technology through the development of a completely oille compreor. The Powerex Scroll Compreor offer a dynamically balanced air end which inure vibrationfree operation. The rotary deign permit a continuou 100% duty cycle. Other tandard feature on the Powerex Scroll Compreor include: a Magnetic Starter, Motor Overload Protection, a High Temperature Shutdown Switch, an Air Cooled Aftercooler and a Single Phae or Three Phae 4 Pole ODP motor. WARNING DRAIN MOISTURE FROM TANK EVERY DAY TO Safety Guideline A SEPARATE SAFETY BOOKLET IS PROVIDED ALONG WITH THIS MANUAL. READ AND UNDERSTAND The SAFETY BOOKLET. Thi manual contain information that i very important to know and undertand. Thi information i provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize thi information, oberve the following ymbol. MAKE SURE EVRYONE OPERATING OR SERVICING THE COMPRESSOR READS AND UNDERSTANDS ALL The INFORMATION PROVIDED. Danger indicate an imminently hazardou ituation which, if not avoided, WILL reult in death or eriou injury. Warning indicate a potentially hazardou ituation which, if not avoided, COULD reult in death or eriou injury. Caution indicate a potentially minor or moderate injury. Intallation Intallation Site 1. The croll compreor mut be located in a clean, well lit and well ventilated area. 2. The area hould be free of exceive dut, toxic or flammable gae, moiture, water, and direct unlight. 3. Never intall the compreor where the ambient temperature i higher than 104 o F or where humidity i high. 4. Clearance mut allow for afe, effective inpection Powerex 150 Production Drive Harrion, OH USA Specification Product Performance Specification Lubrication Operating Voltage Compreion Cycle Motor Overload Protection SES Serie Powerex Simplex Air Compreor See Page 2 Greae-filled Bearing 1Ø 3Ø Scroll 230 Volt, 60 Hz; 230 Volt, 50 Hz /460/575 Volt, 60 Hz IEC Motor Overload Relay Preure Setting Cut-In: 95 pig Cut-Out: 115 pig Cut-In: 115 pig Cut-Out: 145 pig (High Preure Unit) Overpreure Protection Outlet Air Connection Tank Size California Ordinance 462 (L) (2) Tank Iolation Drive Control Panel ASME Safety Valve Factory Set and Sealed 3/8 inch NPT 13 Gallon ASME Rated 175 pig Meet Requirement of thi Ordinance Standard All Unit 3V Belt UL508A Lited IN188613AV 12/11

2 Compreor Specification Model SES02 SES03 SES13 SES05 SES15 and maintenance. 20 inche of clearance for ide i recommended. 5. If neceary, ue metal him or leveling pad to level the compreor. Never ue wood to him the compreor. 6. Never intall the compreor outide. 7. For 3 and 5 HP ingle phae model it i recommended that additional tank volume be added. 3 HP ingle phae model need a minimum of 30 gallon air capacity to limit the number of tart-per-hour to 14 maximum. 5 HP ingle phae model need a minimum of 60 gallon air capacity to limit the number of tart-per-hour to 10 maximum. Ventilation 1. If the croll compreor i located in a totally encloed room, an exhaut fan with acce to outide air mut be intalled. 2. Never retrict the cooling fan exhaut air. 3. Vent the exhaut air outide to prevent the compreor from operating at high temperature and hutting down. 4. Never locate the compreor where hot exhaut air from other heat generating unit may be pulled into the unit. Wiring All electrical connection mut be performed by a qualified electrician. Intallation mut be in accordance with local and national electrical code. 1. Make ure power ource i the ame voltage a the unit required voltage 2. Ue olderle terminal to connect the electric power ource. 3. Remove the two left panel. 4. Pull the electric cable through the electric ource inlet and connect to the primary ide of the contact block. 5. Since looening of wire i poible in hipment, tighten all wire terminal prior to tarting the unit. Piping General Guideline 1. Make ure the piping i lined up without being trained or twited when aembling the piping for the croll HP Phae 3Ø 3Ø 1Ø 3Ø 1Ø Voltage / 460 / / 460 / / 460 / Amp See wiring diagram for amp rating Air End SLAE03EB SLAE03EB SLAE05E (SLAE05EHP) Control Sytem Preure Switch Preure Switch Preure Switch Dicharge Preure (PSIG) ( optional) ( optional) ( optional) Air Delivery (CFM) 100 PSIG and 145 PSIG) 100 PSIG and 145 PSIG) 100 PSIG and 145 PSIG) Compreor Speed (RPM) 2200 (1850) 3140 (2770) 3250 (3250) Dicharge Temp. Ambient temp F Ambient temp F Ambient temp F Noie level db(a) [1.5m from front] Dimenion In Inche (L x W x H) 34 x 21 x x 21 x x 21 x 32.5 Approximate Weight 309 lb. 309 lb. 359 lb (Item in paranthei high preure information) compreor. 2. Appropriate expanion loop or bend hould be intalled at the compreor to avoid tree caued by change in hot and cold condition. 3. Piping upport hould be anchored eparately from the compreor to reduce noie and vibration. 4. Never ue any piping maller than the compreor connection. 5. Ue flexible hoe to connect the outlet of the compreor to the piping o that the vibration of the compreor doe not tranfer to the piping. Remote Intake Piping Powerex Compreor Sytem with pipe thread connector on the intake filter are intended for intallation with remote air intake. Piping for the remote intake ytem mut be intalled at the final operating ite. Under ome condition, the intake piping may facilitate the condenation of humidity in the intake air tream into liquid water. The intake filter upplied by Powerex will not top ingetion of liquid water by the pump. Liquid water going into the pump will damage the pump and void the warranty. Alway intall drip leg with ufficient capacity to capture liquid water in the intake piping before the air filter. Drip leg mut be ized with low enough air velocity to make ure they are effective at capturing liquid water in the intake air and mut be maintained (drained) at frequent interval to make ure they remain effective. Safety Valve Tank mounted compreor are hipped from the factory with afety valve intalled in the air receiver manifold. The flow capacity of the afety valve i equal to or greater than the capacity of the compreor. 1. The preure etting of the afety valve mut be equal or le than the maximum working preure of the air receiver. 2

3 2. Safety valve hould be placed ahead of any poible blockage point in the ytem, i.e. hutoff valve. 3. Avoid connecting the afety valve with any tubing or piping. 4. Manually operate the afety valve every ix month to avoid ticking or freezing. Operation Before tart up 1. Make ure all afety warning, label and intruction have been read and undertood before continuing. 2. Remove any hipping material, bracket, etc. 3. Confirm that the electric power ource and ground have been firmly connected. 4. Check the belt for tightne. 5. Be ure all preure connection are tight. 6. Check to be certain all afety relief valve, etc., are correctly intalled. 7. Securely mount all panel and guard. 8. Check that all fue, circuit breaker, etc., are the proper ize. 9. Make ure the inlet filter i properly intalled. 10. Confirm that the drain valve i cloed. tart-up and Operation 1. Viually check the rotation of the compreor pump. The rotation hould be counterclockwie if viewing the compreor from the belt ide. If the rotation i incorrect, have a qualified electrician correct the upply wiring. 2. Follow all the procedure under Before tart-up before attempting operation of the compreor. 3. Make ure compreor witch i in the OFF poition. 4. Switch the electric ource breaker on. 5. Open the 3/8 inch dicharge valve completely. 6. Turn compreor witch to ON poition and check that the compreor operate without exceive vibration, unuual noie or leak. 7. Cloe the dicharge valve completely. 8. If the preure doe not rie on a three phae unit, turn the unit off. Have a qualified electrician witch the breaker OFF and exchange the L1 and L2 connection (two out of three phae of electric ource) on the control panel. 9. Check the dicharge preure. Alo make ure the air preure rie to the deignated preure etting by checking the dicharge preure gauge. 10. Check the operation of the preure witch by opening the outlet valve and confirming the compreor tart at approximately 95 pig for low preure unit and 115 pig or high preure unit. daily Operation 1. Stop the compreor by turning witch to the OFF poition. NOTE: If the compreor rotate in revere for more than five econd, the check valve need to be cleaned or replaced. 2. Switch the breaker OFF if the compreor i not to be ued for a long period of time. topping the Compreor during normal Operation 1. Cloe the dicharge valve. 2. Allow the air preure to build and the compreor to top. 3. Turn the compreor off by turning witch to the OFF poition. Belt Adjutment Procedure 1. Remove the top panel by removing the two lotted 1/4-20 crew on the rear of the encloure. 2. Looen the four (4) motor lide bolt. 3. Tighten belt by adjuting the belt adjutment bolt. Belt tenion for new belt hould be 57 to 65 lb for the looet belt in the et, then lb after run-in. If the belt tenion fall below 25 lb or chirping i heard a tart up, re-tenion belt. (If uing the deflection method for belt tenion, lb force at mid pan hould give 7/32 belt deflection for a new belt, for a ued belt for 7/32 belt deflection. 4. Tighten the four (4) motor lide bolt. Tighten the two electrical panel ide lide bolt firt then tighten the two pulley ide lide bolt. Figure 1 3

4 Scroll Unit Part Breakdown - Model SES02, SES12, SES03, SES13, SES05, SES15, SF120_PHA, and SF130_PHA /4 INCH FNPT TANK DRAIN 3/8 INCH FNPT AIR OUTLET MAIN POWER INLET 4 X DIA Figure 2 4

5 Ref. No. Decription SES02 / SES12 SES03 / SES13 SES05 / SES15 Qty. 1 Air end (low preure) SL014003AJ SL014003AJ SL016502AJ 1 (high preure) SL014003AJ SL014003AJ SL016511AJ gallon tank AR234800AJ AR234800AJ AR234800AJ 1 3 Unit bae SL303600AV SL303600AV SL303600AV 1 4 Front panel SL304500AV SL304500AV SL304500AV 1 5 Right panel SL304400AV SL304400AV SL304400AV 1 6 Back panel SL304600AV SL304600AV SL304600AV 1 7 Top panel SL304800AV SL304800AV SL304800AV 1 8 Utility panel SL305200AV SL305200AV SL305200AV 3 9 Internal duct SL304901AV SL304901AV SL304901AV 1 10 Left panel SL304300AV SL304300AV SL304300AV 1 11 Maintenance panel 1 SL305000AV SL305000AV SL305000AV 1 12 Inide panel SL304700AV SL304700AV SL304700AV 1 13 Pump bae SL304101AV SL304101AV SL304101AV 1 14 Mounting foot IP630300AV IP630300AV IP630300AV 4 15 H upport SL305100AV SL305100AV SL305100AV 2 16 Inlet filter aembly ST073924AV ST073924AV ST073924AV 1 17 Filter element Motor pulley 2HP (low preure, 2-3V4.45) 3Ø PU202633AV Ø PU202623AV 2HP (high preure, 2-3V3.65) 3Ø PU202632AV Ø PU202622AV 3HP (low preure, 2-3V6.0) - PU202625AV - 1 3HP (high preure, 2-3V5.3) - PU202624AV - 1 5HP (low preure, 2-3V6.9) - - PU009754AV 1 5HP (high preure, 2-3V6.9) - - PU009754AV /4 T x 1/4 P x 90 puh connect ST119702AV ST119702AV ST119702AV /4 inch drain tube PS010300AV PS010300AV PS010300AV 2.0 ft. 22 Corner angle ST185500AV ST185500AV ST185500AV 4 23 Temperature 115 pi AM003011AV AM003011AV AM003011AV 1 Temperature 145 pi AM003012AV AM003012AV AM003012AV 1 24 Sub panel SL305300AV SL305300AV SL305300AV /4 inch bulk head fitting PS006701AV PS006701AV PS006701AV /8 inch bulk head fitting PS006702AV PS006702AV PS006702AV 1 27 Safety valve (Low preure unit) V AV V AV V AV 1 (High preure unit) V AV V AV V AV 1 28 Maintenance panel 2 SL306500AV SL306500AV SL306500AV 1 29 Motor lide bae SL306701AV SL306701AV SL306701AV 1 30 Preure witch (Low preure unit) CW207573AV CW207573AV CW207573AV 1 (High preure unit) CW207595AV CW207595AV CW207595AV 1 31 Lighted off/on witch PE000560AV PE000560AV PE000560AV /8 inch ball valve ST079802AV ST079802AV ST079802AV /4 inch ball valve ST079806AV ST079806AV ST079806AV 1 34 Electrical train relief ST188106AV ST188106AV ST188106AV 1 35 Motor 2hp 1 phae MC301579AV hp 3 phae MC303300AV hp 1 phae - MC301579AV - 1 3hp 3 phae ( / 460 V) - MC303301AV - 1 3hp 3 phae (575 V) - MC303302AV - 1 5hp 1 phae - - MC022393AV 1 5hp 3 phae ( / 460 V) - - MC303303AV 1 5hp 3 phae (575 V) - - MC303304AV 1 5

6 Ref. No. Decription SES02 / SES12 SES03 / SES13 SES05 / SES15 Qty. 36 Check valve IP087700AV IP087700AV IP087700AV 1 37 Fan IP632400AV IP632400AV IP632400AV 1 38 Fan guard IP632401AV IP632401AV IP632401AV /8 inch PTFE tube PS001800AV PS001800AV PS001800AV 2.5 ft. 40 Belt 2hp low preure BT009001AV hp high preure BT009001AV hp low preure - BT013800AV - 2 3hp high preure - BT012001AV - 2 5hp low/high preure - - BT010701AV 2 41 High temp light PE000538AV PE000538AV PE000538AV 1 42 Unit preure gauge IP632603AV IP632603AV IP632603AV 1 GA032201AV (PHA UNIT) Hourmeter PE001004AV PE001004AV PE001004AV 1 44 Jic fitting ST186422AV ST186422AV ST186422AV 1 45 Braided hoe SM001502AV SM001502AV SM001502AV 1 46 Rubber mounting block AG007501AV AG007501AV AG007501AV 3 47 After cooler SL300101AV SL300101AV SL300101AV 1 48 u Cabinet crew ST129304AV ST129304AV ST129304AV Fan cord IP632800AV IP632800AV IP632800AV 1 50 Intake adaptor plate IP088400AV IP088400AV IP088400AV 1 51 Adaptor plate gaket IP088200AV IP088200AV IP088200AV /4-20 crew ST074003AV ST074003AV ST074003AV /8 inch PTFE tube PS001800AV PS001800AV PS001800AV 1 ft. 54 3/8 x 3/8 x 90 puh connect ST119705AV ST119705AV ST119705AV 2 Part unique to: SF120_PHA SF130_PHA 3 Deep bae SL305401AV SL305401AV 1 18 Motor pulley (50 Hz) PU202623AV PU202626AV 1 35 Motor (50 Hz) MC301578AV MC301578AV 1 40 Belt (50 Hz) BT012001AV BT010701AV 2 42 Gauge GA032201AV GA032201AV 1 u Swivel cater ST187901AV ST187901AV 4 u = Not hown 6

7 Maintenance Schedule (ee Pump Manual for How To Intruction) Operating Hour Item Action needed ,000 20,000 Remark Receiver Drain moiture Daily If equiped with an Electric Drain, tet daily Cartridge Filter Clean, Replace l Part # Ventilation Screen Clean l Blower Fan Clean l Fan Duct Clean l Compreor Fin Clean l Compreor Regreae (Every 5000 hour for 145 pig unit) Ue genuine Powerex greae Tip Seal Set Replace (Every 5000 hour for 145 pig unit) Heat Inulation Pipe Replace (Every 5000 hour for 145 pig unit) V-belt Inpect, Replace Readjut l Temperature Senor Confirm operation l Preure Switch Confirm operation l Magnetic Starter Inpect l Replace i contact point i deteriorated Safety Valve Confirm operation l Preure Gauge Inpect l Ventilation Fan Inpect l Replace if malfunction l Inpect Replace Note: 1. Inpect and perform maintenance periodically according to maintenance chedule. 2. The maintenance chedule relate to the normal operating condition. If the circumtance and load condition are advere, horten the interval time and perform maintenance accordingly. 3. Marked Readjut mean the tenion of the V-belt hould be adjuted during the initial tage and inpected every 2,500 hour afterward; lb initially, then lb after run-in. 7

8 Electrical Diagram - Single Phae Unit 230 Volt Figure 3 8

9 Electrical Diagram - Three Phae Unit Volt 2 HP - 5 HP Scroll Encloure Air Compreor Figure 4 9

10 DK699800AJ 2 HP - 5 HP Scroll Encloure Air Compreor CR1 PS1 TR1 L1 L2 L3 MSX OLX GND Figure Scroll Electrical Panel Replacement Part Key # Motor Starter / Control Fue 1 / Fue 2 Preure Switch Fue 3 Model HP Overload Relay Tranformer (2 Required) 115 PSI 145 PSI SES V,3P SES V,3P SES V,3P SES V,3P SES V,3P SES V,3P SES V,3P SES V,1P SES V,3P SES V,3P SES V,3P SES V,3P SES V,1P PE000205AV PE000102AV / PE000210AV PE000204AV PE000102AV / PE000206AV PE000102AV / PE000210AV PE000204AV PE000203AV PE000103AV / PE000207AV PE000102AV / PE000207AV PE000102AV / PE000207AV PE000205AV PE000204AV PE000204AV PS005847AV PS005847AV JP007702AV JP007702AV JP007702AV JP007702AV JP007702AV Control Relay JP007711AV CW207573AV CW207595AV PE000403AV 10

11 Troublehooting Guide PROBLEM CAUSE CORRECTIVE ACTION Power ON light doe not 1. Main diconnect i not ON 1. Switch diconnect to ON appear Power ON light i on but unit will not tart Compreor i running but will not make preure Exceive noie or vibration Compreor hut down on high temperature Compreor turn on / off rapidly Safety valve blow off Motor Overload ha tripped 2. Blown fue or circuit breaker at cutomer provided power upply 3. Blown fue at tranformer 4. Lighted witch i burned out 1. Motor overload ha tripped 2. Wrong or low voltage 3. Starter ha failed 4. Motor ha failed 1. Drive belt came off or too looe 2. Clogged intake filter element 3. Preure relief valve ha opened 4. Exceive tip eal wear 5. Electric tank drain i open continuouly 6. Unit running in the wrong direction 7. Dicharge air i leaking 1. Drive belt ha eparated or flat pot 2. Motor ha failed 3. Pump i damaged 4. Cooling air fan i touching fan guard 1. Room temperature i above 104 F 2. Inlet air duct i obtructed 3. Cooling air fan not running 4. Aftercooler fin clogged 5. Intake filter damaged 6. Compreor i dirty 7. Tip eal worn 1. Receiver tank ha high level of water 2. Compreor check valve ha failed 3. Defective preure witch 1. Preure witch ha failed to open 2. Motor tarter contact welded hut 1. Pump ha failed 2. Motor ha failed 3. Improper wiring 4. Wrong overload etting 5. Low voltage 2. Inpect for any fault replace fue or trip diconnect to ON 3. Replace fue - be ure to ue ame type and ize 4. Replace lighted witch 1. See lat entry of Troublehooting Guide 2. Check incoming power upply and unit power rating 3. Replace contactor aembly 4. Replace motor 1. Replace drive belt and (or) tighten 2. Replace intake filter element 3. Preure witch need replaced or motor contact welded hut 4. Replace tip eal 5. Replace tank drain 6. Correct power connection 7. Check dicharge piping 1. Replace drive belt 2. Replace motor 3. Fix or replace pump 4. Check air fan daily 1. Add ventilation or air conditioning to room 2. Remove obtruction or repoition unit to allow for cooling air 3. Replace cooling air fan 4. Clean aftercooler 5. Check intake filter 6. Clean unit 7. Replace tip eal 1. Replace electric tank drain / drain tank 2. Replace check valve 3. Replace preure witch 1. Replace preure witch 2. Replace motor tarter 1. Fix or replace pump 2. Replace motor 3. Check wiring 4. Check overload etting 5. Check incoming power upply 11

12 Powerex Limited Warranty Warranty and Remedie. (a) General. Powerex warrant each Compreor Sytem, Vacuum Sytem, Vacuum Pump, Compreor Air-End, or Powerex branded Acceory (collectively Product, individually each a Product ) to be free from defect in material and workmanhip ( Defect ) at the date of hipment. EXCEPT AS SET FORTH BELOW, NO OTHER WARRANTY, WHETHER EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, SHALL EXIST IN CONNECTION WITH THE SALE OR USE OF SUCH PRODUCTS. TO THE EXTENT PERMITTED BY LAW, ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED. All claim under thi warranty mut be made in writing and delivered to Powerex, or uch claim hall be barred. Upon timely receipt of a claim, Powerex hall inpect the Product claimed to have a Defect, and Powerex hall repair, or, at it option, replace, free of charge, any Product which it determine to have had a Defect at the time of hipment from Powerex; provided, however, that if circumtance are uch a to preclude the remedying of Defect by repair or replacement, Powerex hall, upon return of the Product, refund to buyer any part of the purchae price of uch Product paid to Powerex. Freight for returning Product to Powerex for inpection hall be paid by buyer. The warrantie and remedie herein are the ole and excluive remedy for any breach of warranty or for any other claim baed on any Defect, or nonperformance of the Product, whether baed upon contract, warranty or negligence. b) Initial Period of Warranty Part and Labor. Powerex warrant and repreent all Product hall be free from Defect for the firt twelve (12) month from the date of hipment by Powerex, or five thouand (5,000) hour of ue, whichever occur firt. During uch warranty period, Powerex hall be fully liable for all Defect in the Product (the Product Defect ), i.e., all cot of repair or replacement, which may include in and out charge, o long a the Product are located in the continental United State, and the Product are reaonably located and acceible by ervice peronnel for removal. In and out charge include the cot of removing a Product from buyer equipment for repair or replacement. (c) Additional Period of Warranty Part Only (No Labor). In addition to the above, Powerex warrant each Powerex branded Compreor Air-End, and Vacuum Pump hall be free of Defect for a period of thirty-ix month from the date of hipment of Product, or 10,000 hour of ue, whichever occur firt. Supplier repair or replacement of any Product hall not extend the period of any warranty of any Product. Thi warranty applie to the exchange of part() found to be defective by an Authorized Powerex Service Center only. (d) Coverage. The above mentioned warranty applie to Powerex manufactured unit or ytem only. (e) Exception. Notwithtanding anything to the contrary herein, Powerex hall have no warranty obligation with repect to Product: (i) that have not been intalled in accordance with Powerex written pecification and intruction; (ii) that have not been maintained in accordance with Powerex written intruction; (iii) that have been materially modified without the prior written approval of Powerex; or (iv) that experience failure reulting from operation, either intentional or otherwie, in exce of rated capacitie or in an otherwie improper manner. (f) The warranty provided herein hall not apply to: (i) any defect ariing from corroion, abraion, ue of inoluble lubricant, or negligent attendance to or faulty operation of the Product; (ii) ordinary wear and tear of the Product; or (iii) defect ariing from abnormal condition of temperature, dirt or corroive matter; (iv) any OEM component which i hipped by Powerex with the original manufacturer warranty, which hall be the ole applicable warranty for uch component. Limitation of Liability. TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW, NOTWITHSTANDING ANYTHING TO THE CONTRARY HEREIN, UNDER NO CIRCUMSTANCES SHALL POWEREX BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTAL, PUNITIVE, SPECULATIVE OR INDIRECT LOSSES OR DAMAGES WHATSOEVER ARISING OUT OF OR IN ANY WAY RELATED TO ANY OF THE PRODUCTS OR GOODS SOLD OR AGREED TO BE SOLD BY POWEREX TO BUYER. TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW, POWEREX S LIABILITY IN ALL EVENTS IS LIMITED TO, AND SHALL NOT EXCEED, THE PURCHASE PRICE PAID. Warranty Diclaimer. Powerex ha made a diligent effort to illutrate and decribe the Product in thi literature accurately; however, uch illutration and decription are for the ole purpoe of identification, and do not expre or imply a warranty that the Product are merchantable, or fit for a particular purpoe, or that the Product will necearily conform to the illutration or decription. Product Suitability. Many juridiction have code and regulation governing ale, contruction, intallation, and/or ue of Product for certain purpoe, which may vary from thoe in neighboring area. While Powerex attempt to aure that it Product comply with uch code, it cannot guarantee compliance, and cannot be reponible for how the product i intalled or ued. Before purchae and ue of a Product, pleae review the Product application, and national and local code and regulation, and be ure that the Product, intallation, and ue will comply with them. Claim. Claim pertaining to the Product, with the exception of warranty claim, mut be filed with Powerex within 6 month of the invoice date, or they will not be honored. Price, dicount, and term are ubject to change without notice or a tipulated in pecific Product quotation. All agreement are contingent upon trike, accident, or other caue beyond our control. All hipment are carefully inpected and counted before leaving the factory. Pleae inpect carefully any receipt of Product noting any dicrepancy or damage on the carrier freight bill at the time of delivery. Dicrepancie or damage which obviouly occurred in tranit are the carrier reponibility and related claim hould be made promptly directly to the carrier. Returned Product will not be accepted without prior written authorization by Powerex and deduction from invoice for hortage or damage claim will not be allowed. UNLESS OTHERWISE AGREED TO IN WRITING, THESE TERMS AND CONDITIONS WILL CONTROL IN ANY TRANSACTION WITH POWEREX any different or conflicting term a may appear on any order form now or later ubmitted by the buyer. All order are ubject to acceptance by Powerex. Powerex 150 Production Drive Harrion, OH USA

Ceiling Mount Air Handler Manual

Ceiling Mount Air Handler Manual www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty

More information

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

12V Portable Diaphragm Compressor Operating and Maintenance Instructions 12V Portable Diaphragm Compressor Operating and Maintenance Instructions (Part No. DC2) Part No. Serial Number Date Purchased Table of Contents Page Safety Messages...2 Guidelines for Product Use...2 Operation

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,

More information

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167 PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 87976466 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION

More information

D Youville College July 31, 2008 New Academic Building Cannon Design Project No. 002935.00

D Youville College July 31, 2008 New Academic Building Cannon Design Project No. 002935.00 SECTION 22 6119 - COMPRESSED-AIR EQUIPMENT FOR LABORATORY AND HEALTHCARE PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged, oilless scroll air compressors. 1.2 DEFINITIONS A. Actual Air: Air

More information

Dehumidifier Users manual. For Models: DH45S DH65S

Dehumidifier Users manual. For Models: DH45S DH65S Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but

More information

Medical Air Systems: Scroll

Medical Air Systems: Scroll GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing

More information

accidents which arise due to nonobservance and the safety information herein.

accidents which arise due to nonobservance and the safety information herein. 20 GALLON COMPRESSOR Model: 7342 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry. This

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

SWIMMING POOL HEAT PUMP

SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical

More information

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support

More information

CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive

More information

LOBOY 16 AIR CONDITIONERS

LOBOY 16 AIR CONDITIONERS INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries

More information

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number: Seaward Products WATER HEATERS OWNER S MANUAL Serial Number: IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, basic safety precautions to reduce the risk of fire, electrical shock,

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

COMPRESSED AIR DRYER

COMPRESSED AIR DRYER COMPRESSED AIR DRYER Model 40211 ASSEMBLY and OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2002 by Harbor Freight Tools.

More information

Compressor Service & Maintenance Manual

Compressor Service & Maintenance Manual Compressor Service & Maintenance Manual C Series COMPRESSOR (D)C1103 (D)C1203 (D)C2106 (D)C2206 (D)C3210 Copyright 2006 DCI. All Rights Reserved. 92311, Rev. C, 08/13 1 C1000 Series Service & Maintenance

More information

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Air Conditioner Water Heater - A Product of HotSpot Energy LLC Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform

More information

CARING FOR YOUR WATER HEATER

CARING FOR YOUR WATER HEATER http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected

More information

543-0032-00, 943-0032-00. User s Manual

543-0032-00, 943-0032-00. User s Manual 543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and

More information

Genuine Bendix. a l v e. c o m p r e. s o r s. s y e r. a i r. d r. s t r o n i c. e l e c. d i s c. b r a k e s. w h e e l. e n d X V.

Genuine Bendix. a l v e. c o m p r e. s o r s. s y e r. a i r. d r. s t r o n i c. e l e c. d i s c. b r a k e s. w h e e l. e n d X V. v a l v e AHEAD OF THE CURVE AHEAD OF THE CURVE Genuine Bendix c o m p r e o r a i r d r y e r e l e c t r o n i c a i r d i c b r a k e w h e e l e n d X V i i o n GENUINE BENDIX NO CUTTING CORNERS. V

More information

Electric Water Heater

Electric Water Heater Electric Water Heater Operation and Installation Manual (LIMITED WARRANTY AND TANK REPLACEMENT POLICY) The following information should be noted at time of installation and retained for future reference.

More information

PC1130 Electric Air Compressor

PC1130 Electric Air Compressor Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1130 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in

More information

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps Troubleshooting Submersible Pumps Fuse overload or circuit breaker trips when motor is started 1. Incorrect line voltage. Check the line

More information

Air Conditioning Systems Warranty Manual. Version 1.8

Air Conditioning Systems Warranty Manual. Version 1.8 Air Conditioning Systems Warranty Manual Version 1.8 1/2015 Air Conditioning System Warranty Contents Purpose 4 External Distribution... 4 Policies 5 Warranty Policy Overview... 5 Warranty Period... 5

More information

15GAL STEEL OIL DRAIN WITH 110V PUMP

15GAL STEEL OIL DRAIN WITH 110V PUMP 15GAL STEEL OIL DRAIN WITH 110V PUMP OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING PLEASE READ AND SAVE THESE INSTRUCTIONS - 2 - INTRODUCTION TO THE BIG

More information

SERIES 12-600 VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

SERIES 12-600 VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE Eemax Inc., 353 Christian Street, Oxford, CT 06478 1 E ema X SERIES 12-600 VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE WARNING

More information

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13 CONTROL PANEL INSTALLATION INSTRUCTIONS Single Phase Simplex Page 2-7 3-Phase Simplex Page 8-13 Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions

More information

Uer manual A50-78813-00002 Important afety intruction 1) Read thee intruction. CAUTION: WARNING: To reduce the rik of electric hock, do not remove the top cover (or the rear ection). No uer erviceable

More information

DUST COLLECTOR 70 GALLON, 2 HP

DUST COLLECTOR 70 GALLON, 2 HP DUST COLLECTOR 70 GALLON, 2 HP Model 45378 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2001 by Harbor Freight

More information

WWW.CALIFORNIAAIRTOOLS.COM Customer Support 1-866-409-4581

WWW.CALIFORNIAAIRTOOLS.COM Customer Support 1-866-409-4581 sound proof AIr CoMprEssor CAbInEt owner's MAnuAl spc03 WWW.CALIFORNIAAIRTOOLS.COM Customer Support 1-866-409-4581 TAbLe OF CONTeNTS INTROduCTION IntroductIon 2 Important Safety InStructIonS 5 components

More information

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN

More information

OWNER S Manual PRINTED IN CANADA 10/2009

OWNER S Manual PRINTED IN CANADA 10/2009 OWNER S Manual PRINTED IN CANADA 10/2009 Table of contents Introduction 2 General Safety Instructions 4 Installation Instructions Location 6 Water piping 7 Electrical 7 Bonding 8 Bonding and plumbing

More information

Installation Manual DIAPHRAGM WELL TANK

Installation Manual DIAPHRAGM WELL TANK Installation Manual DIAPHRAGM WELL TANK IN-LINE SERIES: 2-5 & 7 GALLON VERTICAL SERIES: 14-20-25-32-36-52-65-86-96-119 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON NO LEAD NO LEAD: The weighted average of

More information

Uer manual V01 2007-07 IMPORTANT SAFETY INSTRUCTIONS 1) Read thee intruction. CAUTION: WARNING: To reduce the rik of electric hock, do not remove the top cover (or the rear ection). No uer erviceable part

More information

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Table Z. Troubleshooting Chart for Air Conditioners. Cause Troubleshooting Chart for Air Conditioners Type of Unit Complaint Cause With open-type compressor Electric motor will not start Power failure Check circuit for power source Compressor stuck Locate cause

More information

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact: 7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: [email protected] Website: www.centrair.ca

More information

Owners Manual 2009 PRICE LIST DRYMAXTM. Compressed Air Treatment Products. Refrigerated Air Dryers

Owners Manual 2009 PRICE LIST DRYMAXTM. Compressed Air Treatment Products. Refrigerated Air Dryers 3177 Ridgeway Ct. Commerce Twp., MI 48390 248-624-6300 248-624-0622 FAX Owners Manual 2009 PRICE LIST Compressed Air Treatment Products DRYMAXTM Refrigerated Air Dryers ENERGY SAVING RECYCLING REFRIGERANT

More information

ATLAS AIR COMPRESSOR OPERATING INSTRUCTIONS COMPRESSOR IDENTIFICATION

ATLAS AIR COMPRESSOR OPERATING INSTRUCTIONS COMPRESSOR IDENTIFICATION ATLAS AIR COMPRESSOR OPERATING INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE USING YOUR AIR COMPRESSOR. KEEP THIS MANUAL FOR FUTURE REFERENCE AS TO THE PROPER OPERATION AND MAINTENANCE OF YOUR AIR COMPRESSOR.

More information

Belt Driven Compressors

Belt Driven Compressors Manual Belt Driven Compressors 070708/00004 Table of Contents Page Introduction / Warranty 3 Standard Components 5 Compressor Layout 6 Installation 9 Engine Driven Compressors 11 Maintenance 13 Safety

More information

GAS SAFETY PRECAUTIONS

GAS SAFETY PRECAUTIONS GAS SAFETY PRECAUTIONS Instructions on what to do when a user smells gas can be obtained from the local gas supplier. These instructions must be posted in a prominent location where the unit is to be operated.

More information

SE-100-1, SE-200-1, SE-500-1, and SE-1000-1 AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81) 83 54 10 18 ventas@industrialmagza.

SE-100-1, SE-200-1, SE-500-1, and SE-1000-1 AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81) 83 54 10 18 ventas@industrialmagza. AIR CHAMP PRODUCTS User Manual SE BRAKE MODELS: SE-00-, SE-200-, SE-500-, and SE-000- (i) FORM NO. L-20084-E-040 In accordance with Nexen s established policy of constant product improvement, the specifications

More information

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 INSTRUCTION MANUAL FOR: T15 AIR CONDITIONER McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleanthermal.com INSTRUCTION MANUAL TABLE OF CONTENTS

More information

Report 4668-1b 30.10.2010. Measurement report. Sylomer - field test

Report 4668-1b 30.10.2010. Measurement report. Sylomer - field test Report 4668-1b Meaurement report Sylomer - field tet Report 4668-1b 2(16) Contet 1 Introduction... 3 1.1 Cutomer... 3 1.2 The ite and purpoe of the meaurement... 3 2 Meaurement... 6 2.1 Attenuation of

More information

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury. 1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is

More information

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS HEAT-FLO HOT WATER STORAGE / BOOSTER TANKS MODELS 30-ST, 40-ST, 40L-ST, 60-ST, 60L-ST, 80-ST, 115-ST, 80-ST-C, 115-ST-C FOR SINGLE TANK INSTALLATIONS For

More information

Project Management Basics

Project Management Basics Project Management Baic A Guide to undertanding the baic component of effective project management and the key to ucce 1 Content 1.0 Who hould read thi Guide... 3 1.1 Overview... 3 1.2 Project Management

More information

Multi-Pitch Pitching Machine USER MANUAL

Multi-Pitch Pitching Machine USER MANUAL Multi-Pitch Pitching Machine USER MANUAL TABLE OF CONTENTS Thank you for purchasing the Cimarron Multi-Pitch Pitching Machine. The Cimarron Multi-Pitch Pitching Machine is a high performance pitching machine

More information

SINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006

SINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006 SINGLE PHASE MOTORS INSTALLATION AND MAINTENANCE MANUAL March 21, 2006 Irvine, California (800) 474-0520 Indianapolis, Indiana (800) 866-7973 Hamilton, Ontario (800) 809-0330 e-mail: [email protected]

More information

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada 1-888-845-7330

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada 1-888-845-7330 All about the Use & Care of your Iron Important Safeguards... 2 Iron Safety Instructions... 3 Parts and Features...4 TA B L E O F C O N T E N T S Using Your Iron...6 Cleaning and Maintenance... 8 Warranty...9

More information

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075 Part No. 89047 Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075 Cincinnati, OH 45241-4807 USA ELECTRIC FRYER SAFETY PRECAUTIONS Installation

More information

T-Series Air Conditioner T62 Model

T-Series Air Conditioner T62 Model INSTRUCTION MANUAL T-Series Air Conditioner T62 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

Instructions. Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG. Pressure Relief Procedure.

Instructions. Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG. Pressure Relief Procedure. Instructions Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG Model 24G766 Important Safety Instructions For complete warnings and safety instructions see RoadLazer RoadPak

More information

BOWIE PUMPS OPERATION - MAINTENANCE

BOWIE PUMPS OPERATION - MAINTENANCE BOWIE PUMPS OPERATION - MAINTENANCE PUMPING PRINCIPLE: The meshing owieeof the gears cause a slight depression, with the resulting enmeshing of the gears causing a vacuum drawing the fluid being pumped

More information

tire inflator with pressure gauge

tire inflator with pressure gauge tire inflator with pressure gauge Model 95583 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks

More information

The Storm 20-Gallon Wet/Dry Vac

The Storm 20-Gallon Wet/Dry Vac Mercury Floor Machines, Inc. New Equipment Warranty Limited Warranty Mercury Floor Machines, Inc. warrants new equipment against defects in material and workmanship under normal use and service to the

More information

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm. Table V Troubleshooting Checklist for Refrigeration Systems TROUBLE POSSIBLE CAUSE CORRECTIVE MEASURE High condensing pressure. Low condensing pressure. Air or non-condensable gas in system. Inlet water

More information

PAINT SPRAY GUN WASHER

PAINT SPRAY GUN WASHER PAINT SPRAY GUN WASHER 94996 ASSEMBLY AND OPERATING INSTRUCTIONS Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious

More information

B-AIR BLOWER CUB POWER MODEL # CP-1

B-AIR BLOWER CUB POWER MODEL # CP-1 OWNER S MANUAL B-AIR BLOWER CUB POWER MODEL # CP-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING READ AND SAVE THESE INSTRUCTIONS INTRODUCTION TO B-AIR CP-1 YOUR

More information

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical appliance, basic safety precautions

More information

Safety, Operation and Maintenance Manual with Parts List

Safety, Operation and Maintenance Manual with Parts List Safety, Operation and Maintenance Manual with Parts List 20-Gallon Wet/Dry Vac Important Information and Safety Instructions PLEASE READ BEFORE USE! # 961130020 9/10-Rev 1 20-Gallon Wet/Dray Vac TABLE

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10) Use & Care Manual With Installation Instructions for the Installer Electric Tankless Water Heaters The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations

More information

Ingersoll Rand Providing Customer-Driven Air System Solutions for More Than 100 Years

Ingersoll Rand Providing Customer-Driven Air System Solutions for More Than 100 Years Ingersoll Rand Type-30 Air Ingersoll Rand Providing Customer-Driven Air System Solutions for More Than 100 Years Back then, we called it serving the customer. Today, we call it Solutionizing because your

More information

INSTALLATION and OPERATION RANGE BALL CONVEYOR MODEL NO: BC-001AN

INSTALLATION and OPERATION RANGE BALL CONVEYOR MODEL NO: BC-001AN Easy Picker Golf Products, Inc. 415 Leonard Blvd. N., Lehigh Acres, FL 33971 PH: 239-368-6600 FAX: 239-369-1579 Service: 800-982-4653 SALES: 800-641-4653 www.easypicker.com [email protected] INSTALLATION

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477

More information

Table of Contents WARNING SYMBOLS AND DEFINITIONS

Table of Contents WARNING SYMBOLS AND DEFINITIONS Table of Contents SAFETY INSTALLATION OPERATION MAINTENANCE Safety... 2 Specifications... 4 Installation... 5 Operation... 8 WARNING SYMBOLS AND DEFINITIONS Maintenance... 9 Parts List and Assembly Diagram...

More information

Air Conditioning System

Air Conditioning System Owner s Information Manual Air Conditioning ystem NOTE TO EQUIPMENT OWNER: For your convenience, please record the model and serial numbers of your new equipment in the space provided. This information,

More information

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to

More information

OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608

OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions

More information

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury. 1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is

More information

MICROMAPPER. Users Manual. LAN Wiremap Checker

MICROMAPPER. Users Manual. LAN Wiremap Checker TM MICROMAPPER LAN Wiremap Checker Users Manual (English) November 00, Rev., 9/0 00-00 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. i LIMITED

More information

PC1131 Electric Air Compressor

PC1131 Electric Air Compressor Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in

More information

Trouble Shooting. Pump

Trouble Shooting. Pump Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft

More information

AIR CONDITIONING UNITS

AIR CONDITIONING UNITS A/C Systems Warranty Manual AIR CONDITIONING UNITS Revision 10/2014 Doc. P/N: 10000033E AP 10000033E 10/2014 Contents: I. Spheros North America Warranty Statement II. Warranty Manual 1-7 Purpose of this

More information

Visit our website at: http://www.harborfreight.com. Email our technical support at: [email protected]

Visit our website at: http://www.harborfreight.com. Email our technical support at: tech@harborfreight.com 2.5 CFM Vacuum Pump Item 98076 Danger To prevent explosion, serious injury, and death: Service of air conditioning systems must be done only by trained and experienced technician to avoid overfilling.

More information

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................

More information

MODEL 300505 INSTALLATION INSTRUCTIONS

MODEL 300505 INSTALLATION INSTRUCTIONS WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 [email protected] Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R MAC120R MAC150R MAC 200R Serial # Fuji Clean USA 41-2 Greenwood Road Brunswick, Maine 04011 207-406-2729 www.macblowers.com MACBlowers The Intelligent

More information

Evaluate, Clean, and Tune Guidance

Evaluate, Clean, and Tune Guidance Evaluate, Clean, and Tune Guidance The Evaluate, Clean and Tune (ECT) process serves three essential purposes in the Weatherization Assistance Program (WAP). The first is to evaluate the existing system

More information

123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com

123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com 123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com INTRODUCTION The purpose of this manual is to assist you in the assembly, operation and maintenance of your sprayer

More information

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177 T-SERIES Air Conditioners T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177 88043249 TABLE OF CONTENTS RECEIVING THE AIR CONDITIONER...3 HANDLING AND

More information

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6

More information

Cooling system components, removing and installing

Cooling system components, removing and installing Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate

More information

your Rights Consumer Guarantees Understanding Consumer Electronic Devices, Home Appliances & Home Entertainment Products

your Rights Consumer Guarantees Understanding Consumer Electronic Devices, Home Appliances & Home Entertainment Products Conumer Guarantee Undertanding your Right Conumer Electronic Device, Home Appliance & Home Entertainment Product Voluntary Warranty Guide February 2014 JB Hi-Fi Group Pty Ltd (ABN 37 093 II4 286) The Autralian

More information

Utility Distribution Systems

Utility Distribution Systems Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........

More information

1/3 HP Submersible Sump Pump with Vertical Float Switch

1/3 HP Submersible Sump Pump with Vertical Float Switch 1/3 HP Submersible Sump with Vertical Float Switch Item 68476 Specifications Float Switch Operation Height 7.1 IN. ON / 2.8 IN. OFF Electrical Requirements 120V~ / 60Hz / 7.6A Power Length Maximum Capacity

More information

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE

More information

ClearView 100. Instruction Manual

ClearView 100. Instruction Manual ClearView 100 Instruction Manual Important Safeguards This appliance is not intended for use by children or infirm persons without supervision. Young children should be supervised to ensure that they do

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable 70 Serie - Line monitoring relay 70 SRIS Feature 70.11 70.31 lectronic voltage monitoring relay for ingle and three-phae application Multifunctional type, providing the flexibility of monitoring Undervoltage,

More information

Generator Transfer Switch Model # HTS15-AUTO

Generator Transfer Switch Model # HTS15-AUTO Generator Transfer Switch Model # HTS15-AUTO Congratulations on your purchase of our Single Circuit Generator Transfer Switch, We hope this meets and exceeds your expectations. If at anytime you have any

More information

Owners Manual. Refrigerated Air Dryer. HX75 thru HX2400

Owners Manual. Refrigerated Air Dryer. HX75 thru HX2400 Owners Manual Refrigerated Air Dryer HX75 thru HX2400 IMPORTANT: READ THIS MANUAL CAREFULLY. IT CONTAINS INFORMATION ABOUT SAFETY AND THE SAFETY OF OTHERS. ALSO BECOME FAMILIAR WITH THE PROPER INSTALLATION

More information