PerkinElmer Life and Analytical Sciences, Inc. LANCE camp 384 Kit
|
|
|
- Brian Maximillian Lucas
- 9 years ago
- Views:
Transcription
1 PerkinElmer Life and Analytical Sciences, Inc. LANCE camp 384 Kit AD Assay points AD0262E 1,000 Assay points AD ,000 Assay points AD ,000 Assay points For Laboratory Use CAUTION: A research chemical for research purposes only.
2 INTENDED USE This LANCE camp 384 kit is intended for the quantitative determination of adenosine 3',5'-cyclic monophosphate (camp) in cell culture and cell membrane samples. INTRODUCTION camp is one of the most important second messengers, mediating diverse physiological responses of neurotransmitters, hormones, and drugs. Intracellular concentration of camp is tightly regulated by two membrane-bound enzymes, adenylyl cyclase (AC) and phosphodiesterase (PDE). AC activity promotes the synthesis of camp from ATP while PDE degrades camp to AMP. The activity of AC is controlled through various G-protein -coupled receptors (GPCRs), via their interaction with one of two distinct GTP binding proteins, G αs and G αi. These G proteins are heterotrimeric molecules composed of the subunits G α (s or i), G ß and G γ. Agonist activation of GPCRs leads to the binding of GTP to the G α subunit, causing a conformational change that leads to the dissociation of the trimer into G α and G ßγ. Upon dissociation, G αs is primarily involved in AC stimulation whereas G αi and G ßγ are inhibitory. The measurement of intracellular camp is thus an ideal method for measuring the effect of test compounds on GPCR-mediated AC activation or inhibition. LANCE is a trademark of PerkinElmer, Inc. Alexa Fluor 647 is a registered trademark of Molecular Probes, Inc. (Invitrogen Corp.). 2
3 PRINCIPLES OF THE ASSAY The LANCE camp assay is a homogeneous time-resolved fluorescence resonance energy transfer (TR-FRET) immunoassay designed to measure camp produced upon modulation of adenylyl cyclase activity by GPCRs. The assay is based on the competition between a europium-labeled camp tracer complex and sample camp for binding sites on camp-specific antibodies labeled with the dye Alexa Fluor 647. The europium-labeled camp tracer complex is formed by the tight interaction between Biotin-cAMP (bcamp) and streptavidin labeled with Europium-W8044 chelate (Eu-SA). When antibodies are bound to the Eu-SA/b-cAMP tracer, light pulse at 340 nm excites the Eu-chelate molecules of the tracer. The energy emitted by the Eu-chelate is transferred to an Alexa molecule on the antibodies, which in turn emits light at 665 nm (figure 1). The fluorescence intensity measured at 665 nm will decrease in the presence of camp from test samples and resulting signals will be inversely proportional to the camp concentration of a sample. This assay is intended for the detection of camp produced by live cells or from cellular membrane preparations stimulated with GPCR agonists. For G αs -coupled receptors, agonist stimulation of cells or membrane preparations results in an increase in camp levels, and to a concomitant decrease in fluorescence at 665 nm. Addition of an antagonist will reverse the response, resulting in an increase in signal. In the case of G αi -coupled receptors, cells are stimulated by the AC activator forskolin and by the agonist simultaneously. An agonist will inhibit the forskolin-induced camp production, therefore an increase in LANCE signal will be observed compared with samples treated with forskolin alone. In G αi -coupled systems, antagonists will block the effect of the agonist, resulting in a decrease in LANCE signal toward forskolin-induced levels. In cell-based assays, cells are lysed after stimulation. 3
4 The LANCE camp assay is extremely sensitive and robust. The assay reactions are stable for at least 20 hours at room temperature, with little loss in sensitivity. These characteristics make this kit ideal for HTS screening campaigns. This kit insert describes procedures to perform LANCE camp assays in 384-well microplates in a total assay volume of 24 µl. The assays can be run in different final volumes to accommodate the 96 and 1536 formats if the concentration ratio of the reagents is maintained. (See Summary Protocol sheet on pg 30). The LANCE camp assay can be also performed using GPCR expressed in cell membranes and using adherent cells. Figure 1. LANCE camp Assay Principle. Light pulse at 340 nm excites the Europium-chelate of the Eu-SA/bcAMP tracer. The energy emitted from the Eu-chelate is transferred to the Alexa Fluor 647 labeled anti-camp antibodies bound to the tracer, generating a TR-FRET signal at 665 nm. Residual energy from the Eu-chelate will produce light at 615 nm. camp of a sample competes with the tracer for antibody binding sites and causes signal reduction. 4
5 KIT CONTENTS The reagents are sufficient for 500, 1,000, 10,000 or 50,000 assay points when using the suggested protocols (20 µl or 24 µl reactions in 384-well microplates). The expiration date of the complete package is stated on the outer label. Store at +2 to +8 C protected from light. 5
6 Reagents Component camp Standard AD points 1 ml AD0262E 1,000 points 1 ml AD ,000 points 1 ml AD ,000 points 1 ml Biotin-cAMP 25 µl 25 µl 170 µl 830 µl LANCE Eu-W8044 labeled streptavidin Alexa Fluor 647-anti camp antibody camp Detection Buffer BSA Stabilizer (7.5% solution) White Optiplate- 384 White Proxiplate-384 Plus LANCE Positive Control 25 µl 40 µl 1 bottle, 25 ml Not provided Not provided Not provided Not provided 25 µl 80 µl 2 bottles, 25 ml 1 ml 1 microplate 1 microplate 2 ml 60 µl 670 µl 1 bottle, 250 ml Not provided Not provided Not provided Not provided 280 µl 2 vials, 1.70 ml 5 bottles, 250 ml Not provided Not provided Not provided Not provided LANCE Negative Control Not provided 2 ml Not provided Not provided 6
7 Description of Kit Components The camp Standard (50 µmol/l) is supplied in 50 mmol/l sodium acetate with 0.09% sodium azide as preservative. The Biotin-cAMP tracer is supplied in 10 mmol/l Tris-HCl buffered (ph 8.0) salt solution with 1 mmol/l ethylenediaminetetraacetic acid (EDTA), 0.1% bovine serum albumin (BSA), and 0.05% sodium azide as preservative. The LANCE Eu-W8044 labeled streptavidin is supplied in 50 mmol/l Tris-HCl buffered (ph 7.8) salt solution with 0.9% sodium chloride (NaCl), 0.1% BSA, and 0.05% sodium azide as preservative. The Alexa Fluor 647-anti camp antibody is supplied in 50 mmol/l Tris-HCl buffered (ph 7.8) salt solution with 0.9% NaCl, 0.1% BSA, and 0.05% sodium azide as preservative. Ready-for-use camp Detection Buffer (ph 7.4) composed of 50 mmol/l HEPES, 10 mmol/l calcium chloride (CaCl 2 ), and 0.35% Triton X The BSA stabilizer is supplied in 50 mmol/l Tris buffered (ph 7.8) salt solution with 7.5 % BSA, and <0.1% sodium azide as preservative. The white OptiPlate-384 and white ProxiPlate-384 Plus are microplates suitable for luminescence- and fluorescence-based assays. They have been validated for LANCE camp assays. The LANCE Positive Control is a ready-for-use solution composed of Eu-W1024-biotin and SA-APC in polarization buffer. The LANCE Negative Control is a ready-for-use solution composed of Eu-W1024-biotin and SA in polarization buffer. 1 Triton is a registered trademark of Rohm and Haas Co. 7
8 MATERIALS REQUIRED BUT NOT SUPPLIED WITH THE KIT The LANCE camp 384 kit requires the following items: Item Suggested source* Product no. Stimulation buffer See page 12 Hank's Balanced Salt Solution (HBSS) (1X) (no phenol red) Invitrogen Corp Versene Invitrogen Corp HEPES Buffer Solution (1 mol/l) Milli-Q water BSA Stabilizer (7.5% solution)*** Forskolin IBMX** OptiPlate-384, white*** ProxiPlate-384 Plus, white*** OptiPlate-96, white Invitrogen Corp PerkinElmer, Inc. Sigma-Aldrich, Inc. Sigma-Aldrich, Inc. PerkinElmer, Inc. PerkinElmer, Inc. PerkinElmer, Inc. CR F 6886 I (pack of 50) (pack of 200) (pack of 50) (pack of 200) (pack of 50) (pack of 200) OptiPlate-1536, white PerkinElmer, Inc (pack of 20) TopSeal-A 384 PerkinElmer, Inc LANCE Controls*** PerkinElmer, Inc. Liquid handling system (FlexDrop, Evolution PerkinElmer, Inc. EP 3, or equivalent) TRF detection readers (ViewLux, Fusion, VICTOR, EnVision, or equivalent) PerkinElmer, Inc. * Equivalent sources can be substituted ** 3-Isobutyl-1-Methylxanthine *** These items are provided in the AD02662E - 1,000 assay points Kit 2 Milli-Q is a registered trademark of Millipore Corp. FlexDrop, Evolution, ViewLux, Fusion, VICTOR, and EnVision are trademarks of PerkinElmer, Inc. 8
9 WARNINGS AND PRECAUTIONS This LANCE camp 384 kit is intended for research use only. Reagents contain sodium azide (NaN 3 ) as a preservative. Sodium azide may react with lead and copper plumbing to form highly explosive metal azides. On disposal, flush with a large volume of water to prevent azide build-up. Disposal of all waste should be in accordance with local regulations. INSTRUMENT SETTINGS & CALIBRATION It is critical to ensure that the instruments possess the right filters (excitation at 320 or 340 nm; emission at 615 and 665 nm). For the VICTOR and EnVision instruments, modifications to locked protocols according to the table below are recommended. Adjustments to the locked protocols can be made after copying them under a new name (e.g. Copy LANCE High Count 615 and 665 labels ). To perform the flatfield calibration on the ViewLux instrument, we recommend using the LANCE positive control as the reference sample (LANCE Controls, prod. no. AD0163) rather than the LANCE camp 384 kit reagents. The LANCE positive control should be used diluted 1:5 in water. The volume of the sample should be the same as the assay sample volume (20 µl or 24 µl as recommended in the assay protocol). The flatfield calibration is performed using the calibration wizard for both 615 nm and 665 nm channels. Details of the protocol can be found in the ViewLux Reference Manual. 9
10 The ability of the readers to detect LANCE chemistry can be assessed using the LANCE Positive and Negative Controls (provided in the 1,000 assay points kits). The volume of the sample should be the same as the assay sample volume (20 μl or 24 µl as recommended in the assay protocol). We describe below the protocol for a 24 μl assay: Allow the vials to reach room temperature before use. Dilute the controls 1:5 in water. Dispense 24 µl of the diluted Positive Control in 12 wells of a white Optiplate-384. Similarly dispense 24 µl of the diluted Negative Control in 12 another wells. For 96-well and 1536-well microplates, use dispense volumes of 40 µl and 8 µl, respectively. For a ProxiPlate- 384 Plus, use dispense volumes of 20 μl. Measure fluorescence within 30 minutes using the LANCE protocol. Typically, in Optiplate-384 microplates, the LANCE Positive Control gives a signal higher than 100,000 counts, while the LANCE Negative Control produces less than 5,000 counts. The signal-to-noise (Positive/Negative) ratio is usually around
11 Parameter VICTOR EnVision ViewLux* Flash Energy High N/A N/A Area Flash Energy % 600,000 Level Excitation Filter 320 / 340 UV2 320 DUG11 (UMB, AMC) Integrator Cap 3 N/A N/A Integrator Level 2x LANCE High Count 615 Emission Filter 1) 615 2) 665 N/A 1) Eu 615 2) APC 665 N/A Delay Time 50 µs 60 µs 50 µs Readout speed, gain and binning Number of Flashes Window 100 µs (200 µs**) 1) 618/8 (Eu) 2) 671/8 (LANCE) N/A N/A Medium, High and 2x N/A 100 N/A 100 µs (200 µs**) 354 µs Mirror module N/A 462 (D400/ N/A D630) or 412 (D400) Cycle 2000 µs 2000 µs N/A * Measurement time of 20 seconds recommended for the ViewLux ** If signal too low with 100 µs Similar settings as the VICTOR settings can be applied for Fusion instruments, but longer window time (e.g. 300 μs) and 340 nm excitation filter are needed. 11
12 STANDARD CURVE ASSAY PROTOCOL 1. Preparation of Stimulation Buffer Make fresh. Prepare only the amount needed within one day. We recommend a Stimulation Buffer made of HBSS 1X solution (Invitrogen Corp.) and containing 5 mmol/l HEPES buffer (Invitrogen Corp.) and 0.01% 0.1% BSA (ph 7.4). Alternative buffers such as PBS with 0.1% BSA can be used as well. In cell-based assays, the Stimulation Buffer should include IBMX (see page 20). Important Note : The use of BSA is mandatory in LANCE camp assays. We recommend using the BSA stabilizer 7.5% solution (CR84-100; included in the 1,000 assay points kit), which is a highly purified preparation of BSA, free of Europium & heavy metal ions contaminants. Protocol to make 15 ml of Stimulation Buffer HBSS 1X containing 5 mm HEPES, 0.1% BSA, ph 7.4 To a tube, add 14 ml of HBSS 1X, 75 µl of 1M HEPES, 200 µl of 7.5% BSA Stabilizer. Adjust the ph to 7.4 and complete the volume to 15 ml with HBSS 1X. 12
13 2. Preparation of camp Standard Serial Dilutions in Stimulation Buffer Dilute the camp Standard solution (50 µmol/l) in Stimulation Buffer according to the table below. Dilution [final in assay] (mol/l) [intermediate ] (mol/l) Volume of dilution Stimulation Buffer 1 1 X X µl of 50 µmol/l 92 µl 2 3 X X µl of dil 1 70 µl 3 1 X X µl of dil 2 60 µl 4 3 X X µl of dil 3 70 µl 5 1 X X µl of dil 4 60 µl 6 3 X X µl of dil 5 70 µl 7 1 X X µl of dil 6 60 µl 8 3 X X µl of dil 7 70 µl 9 1 X X µl of dil 8 60 µl 10 3 X X µl of dil 9 70 µl 11 1 X X µl of dil µl µl 13
14 3. Preparation of Alexa Fluor 647-anti camp Antibody Solution in Stimulation Buffer Prepare the antibody solution by making a 1/100 dilution of the Alexa Fluor 647-anti camp antibody solution in the Stimulation Buffer. Example: Add 5 µl of the antibody solution to 495 µl of Stimulation Buffer, and mix by inverting the tube up and down. 4. Preparation of Detection Mix in Detection Buffer Step 1. Dilute the LANCE Eu-W8044 labeled streptavidin (Eu-SA) in camp Detection Buffer Step 2. Dilute the BiotincAMP (b-camp) in camp Detection Buffer Step 3. Prepare the Detection Mix from Step 1 and Step 2 dilutions Add 5 µl of Eu-W8044 labeled streptavidin (Eu-SA) to 85 µl of camp Detection Buffer. Add 5 µl of Biotin-cAMP (bcamp) to 25 µl of camp Detection Buffer. a) Add 615 µl of Detection Buffer to a tube b) Add 5 µl of Eu-W8044 dilution (from Step 1) c) Mix gently d) Add 5 µl of b-camp dilution (from Step 2) e) Mix gently f) Incubate for at least 15 minutes at room temperature 14
15 5. Standard Curve Assay Protocol The assays are performed in triplicates in a white OptiPlate-384 or ProxiPlate-384 Plus microplate in a total volume of 20 µl or 24 µl. For other assay formats, please refer to the protocol table presented on Page 30. For OptiPlate-384 microplates (total assay volume of 24 µl): a) Add 6 μl of camp Standard dilutions. b) Add 6 μl of Antibody Solution. c) Incubate for minutes at room temperature. d) Add 12 μl of Detection Mix. e) Cover microplate with another plate or with a TopSeal-A film and incubate for 60 minutes at room temperature. f) Read on a TRF detection instrument. Remove the TopSeal- A prior to reading. g) Additional readings can be performed for up to 20 h after tracer addition without significant decrease in assay sensitivity. See Recommendations on the Read-Time for the LANCE camp Assay (page 18). For OptiPlate-384 and ProxiPlate-384 microplates (total assay volume of 20 µl): a) Add 5 μl of camp Standard dilutions. b) Add 5 μl of Antibody Solution. c) Incubate for minutes at room temperature. d) Add 10 μl of Detection Mix. 15
16 e) Cover microplate with another plate or with a TopSeal-A film and incubate for 60 minutes at room temperature. f) Read on a TRF detection instrument. Remove the Top- Seal-A prior to reading. g) Additional readings can be performed for up to 20 h after tracer addition without significant decrease in assay sensitivity. See Recommendations on the Read-Time for the LANCE camp Assay (page 18). Representative camp standard curves generated in Optiplate- 384 microplates in a total volume of 24 µl are presented in Figures 2 and 3. IC 50 values of 2-3 nm with a detection limit of approximately 1 fmol/well are determined. Similar results are obtained in ProxiPlate-384 Plus microplates using an assay volume of 20 µl (data not shown). Please note that depending on the instrument and the lot of kit used, the level of counts and S/B ratio may slightly vary without affecting the assay robustness. 16
17 LANCE Signal (665 nm) VICTOR IC50 = 2.4 nm EnVision IC50 = 2.2 nm log [camp] M Figure 2. Typical LANCE camp standard curves obtained on EnVision and VICTOR instruments. A single plate with camp standard dilutions was read with both the EnVision and VICTOR instruments after 1 h incubation. LANCE Signal (665 nm) ViewLux IC50 = 3.7 nm log [camp] M Figure 3. Typical LANCE camp standard curve obtained on a ViewLux instrument. A plate with camp standard dilutions was read with the ViewLux instrument after 1 h incubation. 17
18 6. Recommendations on the Read-Time for the LANCE camp Assay Following the addition of the assay detection mixture, equilibrium binding is established over a period of time between the camp produced in the assay, the camp tracer, and the Alexa-labeled anti-camp antibody. During the time that this equilibrium is being established, the IC 50 or EC 50 measured for the assay will shift slightly. The time-course of this shift needs to be taken into account when choosing the readtime for the assay post detection mixture addition. Figure 4 shows the time-course of the change in the pic 50 of the standard curve on the same plate read at one hour intervals over 1-6 hours and then again after 20 hours. The plate was covered with a plate seal for the overnight incubation to prevent evaporation. As this figure shows, the shift in the pic 50 occurs more rapidly during the first 1 to 2 hours following the addition of the detection mixture. The shift then slows down as the incubation time progresses pic Time (Hours) Figure 4. Time-Course for the standard curve in the LANCE camp Assay. The assay was measured on the ViewLux. 18
19 If the assay is read at a consistently specific time following the addition of the detection mixture, the IC 50 or EC 50 obtained is highly reproducible. Figure 5 shows the superposition of the standard curve obtained from ten separate plates when the plates were each read following 3 hour incubation. Signal (665 nm) Concentration of camp (M) Plate 1 Plate 2 Plate 3 Plate 4 Plate 5 Plate 6 Plate 7 Plate 8 Plate 9 Plate 10 Figure 5. LANCE camp standard curve generated in multiple microplates and read on EnVision instrument after 3 hour incubation. Therefore, if highly reproducible IC 50 or EC 50 values are required from plate-to-plate and day-to-day it is recommended that a consistent read-time is maintained. If the read-time is consistent, it can be any time at least one hour post addition of the detection mixture. However, if precise timing is not practical for reasons such as instrument availability or scheduling conflicts, it is recommended that the read-time be increased into the range of 2-6 hours or overnight, when the equilibrium is more fully established. 19
20 CELL ASSAY OPTIMIZATION GUIDELINES Development of a LANCE camp assay for a specific receptor requires the optimization of the following parameters: 1. IBMX Concentration: We recommend using IBMX at a concentration of 0.5 mmol/l in Stimulation Buffer. At this concentration, IBMX does not reduce the signal in camp standard curves. The IBMX concentration may need further optimization in cell-based assays when working with different cell lines. 2. Cell Number: It is strongly recommended to generate forskolin dose-response curves in order to establish the optimal cell number per well. We suggest testing from 1,000 to 12,000 cells per well in a 24 µl assay. The optimal cell number will be the one for which the forskolin dose-response curve covers most of the linear region of a camp standard curve. LANCE Signal (665 nm) Control no camp Control 1 μm camp log [forskolin] M EnVision HEK-293 cells/well 1,000 3,000 6,000 Figure 6. Forskolin dose-response curves obtained with HEK-293 cells. Assay measured on the EnVision. 20
21 The LANCE signal is plotted as a function of the log of the concentration of forskolin for each of the 3 cell concentrations tested (Figure 6). The controls signals are plotted to provide the minimum and maximum values of the possible signal range. The optimal cell number will be the one for which the forskolin doseresponse curve covers most of the linear region of a camp standard curve (see Figure 7). LANCE Signal (665 nm) camp standard curve log [camp] M Forskolin dose-response curve log [forskolin] M EnVision HEK-293 cells/well 1,000 3,000 6,000 Figure 7. Determination of the optimal HEK-293 cell number In this example, the forskolin dose-response obtained with HEK cells shows that 3,000 cells/well provides a response that falls within the linear region of the camp curve which is presented on the left part of figure Forskolin Concentration: An optimized forskolin concentration is required to produce G αi agonist dose-response curves. Forskolin is typically used at a concentration producing either 50% (EC 50 ) or 80% (EC 80 ) of maximal adenylyl cyclase activation. To determine the EC 50 or EC 80, the forskolin signal inhibition curve should be transformed to a camp production curve, using a camp standard curve run in parallel. Assays performed at the EC 50 will be more sensitive to weak agonists compared to those performed at the EC 80. On the other hand, assays performed using a forskolin concentration equivalent to the EC 80, allow an enhanced signal window. 21
22 4. Agonist Concentration: The presence of an agonist is required to produce G αs and G αi antagonist dose-response curves. The optimal concentration for the agonist is determined as follows: Two agonists dose-response curves are generated, one in the absence of antagonist, and the other with an excess of a reference antagonist (~10 µmol/l). The two curves are plotted on a same graph. The agonist concentration at which the difference between the two curves is the largest is selected. This is often observed at the EC80 of the agonist, which is the concentration of agonist leading to 80% of the maximal response. We do not recommend an agonist concentration higher than the EC80 for antagonist dose-response curves. 5. Stimulation Time: We recommend a 30-minute stimulation time. Optimization can be performed by evaluating stimulation responses from 15 to 60 minutes. 6. Read Time: See Recommendations on the Read-Time for the LANCE camp Assay on page 18. GENERAL CELL-BASED ASSAY PROTOCOL NOTE: In cell based-assays, IBMX should be added to the Stimulation Buffer (see page 20). DMSO at concentrations up to 2% during cell stimulation does not affect assay performance. However, it is recommended to titrate DMSO with each cell line used. Cell and Compound Preparation 1. Harvest cells with a non-enzymatic cell dissociation solution (like Versene). 2. Wash cells once with HBSS. 3. Resuspend the cells in Stimulation Buffer at a concentration of 2 x 10 6 cells per ml (12,000 cells per 6 μl). Further dilute cells to obtain the cell number needed. It is recommended to test 12,000, 6,000, 3,000 and 1,000 cells per 6 μl. Prepare a "no cell" control or a camp Standard curve in parallel (see page 13). 22
23 4. Add the Alexa Fluor 647-labeled antibodies to the final cell suspension by making a 1/100 dilution of the stock solution in the cell suspension. 5. Make test compounds serial dilutions at 2-fold stimulation concentrations in Stimulation Buffer. If more than one test compound is added (e.g. agonist-forskolin, antagonistagonist, or forskolin-antagonist-agonist), mix the compounds in Stimulation Buffer in order for all of them to be at a 2-fold concentration during the stimulation step. LANCE camp Assay The assay is performed in a white OptiPlate-384 or ProxiPlate- 384 Plus microplate in a final assay volume of 24 ou 20 µl. For OptiPlate-384 microplates (total assay volume of 24 µl): 1. Add 6 μl of the test compound dilutions. 2. Add 6 μl of cell suspension (containing the Alexa-labeled antibodies). 3. Stimulate cells for minutes at room temperature. 4. Add 12 μl of Detection Mix (see preparation on page 14). 5. Cover plate with another plate or with a TopSeal-A film and incubate for 60 minutes at room temperature. 6. Read on a TRF detection instrument. Remove the TopSeal- A film from the microplate prior to reading 7. Additional readings can be performed for up to 20 hours after tracer addition without significant decrease in assay sensitivity. See Recommendations on the Read-Time for the LANCE camp Assay (page 18). 23
24 For OptiPlate-384 and ProxiPlate-384 Plus microplates (total assay volume of 20 µl): 1. Add 5 μl of the test compound dilutions. 2. Add 5 μl of cell suspension (containing the Alexa-labeled antibodies). 3. Stimulate cells for minutes at room temperature. 4. Add 10 μl of Detection Mix (see preparation on page 14). 5. Cover plate with another plate or with a TopSeal-A film and incubate for 60 minutes at room temperature. 6. Read on a TRF detection instrument. Remove the TopSeal-A film from the microplate prior to reading. 7. Additional readings can be performed for up to 20 hours after tracer addition without significant decrease in assay sensitivity. See Recommendations on the Read-Time for the LANCE camp Assay (page 18). Please note that alternative orders of addition of reagents or cell suspensions may give satisfactory performance, but should be validated in each case. 24
25 DATA ANALYSIS The LANCE signal obtained at 665 nm can be used directly for data analysis of camp standard curves, Z determination and compound library screening. Counts at 665 nm obtained in camp standard curves will allow the determination of the amount of camp produced in stimulated cells. The signal at 615 nm is useful to identify dispensing or quenching problems. Normally, the signal at 615 nm varies by about 10 15% in a camp standard curve. Counts at 615 nm are higher when the signal at 665 nm is minimal (e.g. at the highest camp concentration) and are lower when the signal at 665 nm is maximal (i.e. in the absence of competing camp). A test compound giving lower signal at both 665 nm and 615 nm wavelengths may be quenching fluorescence, or might indicate a dispensing problem. Some test compounds may interfere the signal in the LANCE camp assay, giving either false positive or false negative signals. There are compounds which may quench signal by absorbing light or by other mechanisms. For minimizing false positives and false negatives in the primary screen a quench correction is recommended. Quench correction can be performed using the blankcorrected ratio 665 nm/615 nm. The following equation gives the corrected signal: F 665,CS = [(F 665,S F 665,BL ) x F 615,MAX ]/F 615,S The blank value is separately measured by adding buffer to the wells to obtain blank reading at 665 nm (F 665,BL, e.g. 80 counts). This reading is specific for the plate type, reader and measurement protocol. 25
26 Signals at 665 nm (F 665,S ) and at 615 nm (F 615,S ) are measured from sample wells containing all the assay components including test compounds. The nonquenched signal at 615 nm is obtained from the highest camp concentration in the standard curve (F 615,MAX ). Most of the quenched samples are corrected using this equation. For more information, please see Application note "Quench Correction for LANCE Time-Resolved Fluorescence Resonance Energy Transfer". IMPORTANT NOTES 1. A thorough understanding of this package insert is necessary for successful use of the LANCE camp 384 kit. The reagents supplied with this kit are intended for use as an integral unit. Do not mix identical reagents from kits having different lot numbers in order to maintain a consistency in the total signal between lots. Do not use kit reagents after the expiration date printed on the kit label. 2. Microfuge vials of reagents for a few seconds to improve recovery of content. 3. Do not vigorously vortex solutions containing camp antibody but instead mix gently. 4. The type of plate used is critical to the assay. White OptiPlate-384 microplates are strongly recommended. Black plates will produce less signal but acceptable S/B ratios. 5. It is critical to remove the TopSeal-A film from the plate prior to reading. 26
27 6. It is strongly recommended to use the BSA stabilizer solution (7.5% solution) available from PerkinElmer (prod. no. CR84-100) to make the Stimulation Buffer. This solution is specifically designed for the LANCE assays. 7. When preparing the Detection Mix, always dilute the Eu-SA component first, and then add the Biotin-cAMP component to the Eu-SA solution. WARRANTY Purchase of the product gives the purchaser the right to use this material in his own research, development, and investigational work. The product is not to be injected into humans or used for diagnostic procedures. PerkinElmer Life and Analytical Sciences reserves the right to discontinue or refuse orders to any customer who plans to use these products for any other purposes. PerkinElmer Life and Analytical Sciences provides the product AS IS and does not warrant or guarantee that the product is merchantable or satisfactory for any particular purpose, nor free from any claim of foreign or domestic patent infringement by a third party, and there are no warranties, expressed or implied, to such effect. PerkinElmer Life and Analytical Science, will not be liable for any incidental, consequential or contingent damages involving product use, including but not limited to damage to property or personal injuries. All information supplied with the product and technical assistance given is believed to be accurate, but it remains the responsibility of the investigator to confirm all technical aspects of the application. We appreciate receiving any additions, corrections, or updates to information supplied to the customer. 27
28 LITERATURE Scientific Papers: Hemmila I. (1999): LANCE : Homogeneous Assay Platform for HTS. J Biomol Screen. 4 (6), Application Notes: Quench Correction for LANCE Time-Resolved Fluorescence Resonance Energy Transfer _11 A Comparison of LANCE camp Assay Performance to that of the TR-FRET (Company C) and Enzyme Complementation camp Assay (Company D) Competitive Technologies. Posters: Hurt, S., Harney, H., Xie, H., Le, H., Stanaker, R., Illy, C., and Manchanda, R. (2005): Automation of a GPCR cell-based functional assay on the Cellular Workstation system using the LANCE camp technology. Presented at SBS Kasila, P. and Harney, H. (2005): LANCE camp Increased sensitivity, stability and overall assay performance with G αs and G αi coupled receptors in a miniaturized 1536-well format. Presented at ScreenTech Kasila, P. and Xie, H. (2005): A comprehensive comparison of state of the art camp assays. Presented at SBS Kasila, P., Xie, H., Harney, H, Raneri, A., and Warner, G. (2005): LANCE camp + Evolution P 3 + ViewLux : uhts. Presented at SBS Kasila, P. and Xie, H. (2005): LANCE camp - A uhts camp detection assay for use with membranes. Presented at SBS For a complete documentation listing, please consult our Web site: 28
29 PATENTS LANCE -type assays and certain reagents used therefore may be covered by one or more of the following patents: US 4,925,804, US 5,637,509, EP , DE , AT 84150, US 4,761,481, US 6,242,268, JP , EP , EP , DE , DE , CA , US 4,920,195, EP , DE , US 5,032,677, EP , DE , CA , US 5,055,578, US 5,106,957, US 5,116,989, US 5,245,038, US 5,252,740, US 5,202,423, US 5,324,825, EP , DE , AT , US 5,457,186, US 5,571,897, EP , DE The Alexa Fluor 647 dye used to label the anti camp antibodies is licensed from Molecular Probes, Inc. 29
30 LANCE camp 384 Kit Summary Protocol Sheet General cell-based assay protocols for 96, 384 and 1536 formats Opti- Plate-96 OptiPlate-384 & ProxiPlate- 384 Plus Opti- Plate Total Assay Volume 40 µl 20 µl 24 µl 8 µl Add camp Standards or forskolin and agonist/ antagonist dilutions Add cell suspension containing the Alexa Fluor 647-anti camp antibodies Incubate Add Detection Mix (containing the Eu-labeled streptavidin and the BiotincAMP) Incubate 10 µl 5 µl 6 µl 2 µl 10 µl 5 µl 6 µl 2 µl min at RT 20 µl 10 µl 12 µl 4 µl 1 20 h at RT Measure the TR-FRET signal See Instrument settings on page 9 LANCE is a trademark of PerkinElmer, Inc. 30
31 31
32 PerkinElmer Life and Analytical Sciences, Inc. 710 Bridgeport Avenue Shelton, CT USA (800) or (+1) For a complete list of global offices, visit PC
LANCE Eu-labeled antibodies for serine/threonine kinase assays
AD0078P-1 (en) 1 LANCE Eu-labeled antibodies for serine/threonine kinase assays For Research Use Only These instructions for use apply to the following reagents: AD0094 LANCE Eu-W1024 phospho-threonine
Escherichia coli Host Cell Proteins (E. coli HCP) Kit
TECHNICAL DATA SHEET AlphaLISA Research Reagents Caution: For Laboratory Use. A research chemical for research purposes only. Escherichia coli Host Cell Proteins (E. coli HCP) Kit Product No.: AL261 C/F
IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.
IgM ELISA For the quantitative determination of IgM in human serum and plasma For Research Use Only. Not For Use In Diagnostic Procedures. Please read carefully due to Critical Changes, e.g., Calibrator
AlphaLISA Human Insulin kit
Technical Data Certificate of Analysis Caution: For Laboratory Use. Research chemicals for research purposes only. AlphaLISA Insulin Kit PRODUCT NUMBERS: AL204C (500 ASSAY POINTS) AL204F (5 000 ASSAY POINTS)
Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.
K-ASSAY Mouse IgM ELISA For the quantitative determination of IgM in mouse biological samples Cat. No. KT-407 For Research Use Only. 1 Rev. 072309 K-ASSAY PRODUCT INFORMATION Mouse IgM ELISA Cat. No. KT-407
ArC Amine Reactive Compensation Bead Kit
ArC Amine Reactive Compensation Bead Kit Catalog no. A1346 Table 1. Contents and storage information. Material Amount Composition Storage Stability ArC reactive beads (Component A) ArC negative beads (Component
Quick Guide to AlphaScreen SureFire Assay Optimization
PPLITION NOT lpha Technology Quick uide to lphascreen Sureire ssay Optimization Introduction Screening kinase activities in cell-based assays offers advantages over the more traditional biochemical approach
EdU Flow Cytometry Kit. User Manual
User Manual Ordering information: (for detailed kit content see Table 2) EdU Flow Cytometry Kits for 50 assays: Product number EdU Used fluorescent dye BCK-FC488-50 10 mg 6-FAM Azide BCK-FC555-50 10 mg
Optimizing Performance of the Transcreener ADP Assay for the BioTek Synergy 2 and 4 Multi-Mode Microplate Readers
Optimizing Performance of the Transcreener ADP Assay for the BioTek Synergy 2 and 4 Multi-Mode Microplate Readers Brad Larson 1, Karen Kleman-Leyer 1, Xavier Amouretti 2 1 BellBrook Labs, Madison, WI,
ab185915 Protein Sumoylation Assay Ultra Kit
ab185915 Protein Sumoylation Assay Ultra Kit Instructions for Use For the measuring in vivo protein sumoylation in various samples This product is for research use only and is not intended for diagnostic
Hydrogen Peroxide Cell-Based Assay Kit
Hydrogen Peroxide Cell-Based Assay Kit Item No. 600050 www.caymanchem.com Customer Service 800.364.9897 Technical Support 888.526.5351 1180 E. Ellsworth Rd Ann Arbor, MI USA TABLE OF CONTENTS GENERAL INFORMATION
Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2
Uscn Life Science Inc. Wuhan Website: www.uscnk.com Phone: +86 27 84259552 Fax: +86 27 84259551 E-mail: [email protected] ELISA Kit for Human Prostaglandin E1(PG-E1) Instruction manual Cat. No.: E0904Hu
Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA
KAMIYA BIOMEDICAL COMPANY Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA For the quantitative determination of mouse CKMB in serum, plasma, cell culture fluid and other biological fluids Cat. No. KT-57681
Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #: 3460-07
Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #: 3460-07 TABLE OF CONTENTS GENERAL INFORMATION... 2 Product Description... 2 Procedure Overview... 2 Kit Contents, Storage and Shelf Life... 3
Malachite Green Phosphate Assay Kit
Malachite Green Phosphate Kit Item No. 10009325 Customer Service 800.364.9897 * Technical Support 888.526.5351 www.caymanchem.com TABLE OF CONTENTS GENERAL INFORMATION 3 Materials Supplied 4 Precautions
Measuring Cell Viability/Cytotoxicity: Cell Counting Kit-F
Introduction The Cell Counting Kit-F is a fluorometic assay for the determination of viable cell numbers. Calcein-AM in this kit passes through the cell membrane and is hydrolized by the esterase in the
CytoSelect 48-Well Cell Adhesion Assay (ECM Array, Fluorometric Format)
Product Manual CytoSelect 48-Well Cell Adhesion Assay (ECM Array, Fluorometric Format) Catalog Number CBA-071 CBA-071-5 48 assays 5 x 48 assays FOR RESEARCH USE ONLY Not for use in diagnostic procedures
Human Free Testosterone(F-TESTO) ELISA Kit
Human Free Testosterone(F-TESTO) ELISA Kit Catalog Number. MBS700040 For the quantitative determination of human free testosterone(f-testo) concentrations in serum, plasma. This package insert must be
Phosphate Assay Kit (Colorimetric)
Product Manual Phosphate Assay Kit (Colorimetric) Catalog Number STA-685 1000 assays FOR RESEARCH USE ONLY Not for use in diagnostic procedures Introduction Phosphorus exists as a soluble free phosphate
Genomic DNA Extraction Kit INSTRUCTION MANUAL
Genomic DNA Extraction Kit INSTRUCTION MANUAL Table of Contents Introduction 3 Kit Components 3 Storage Conditions 4 Recommended Equipment and Reagents 4 Introduction to the Protocol 4 General Overview
MTT Cell Proliferation Assay
ATCC 30-1010K Store at 4 C This product is intended for laboratory research purposes only. It is not intended for use in humans, animals or for diagnostics. Introduction Measurement of cell viability and
Chem 405 Biochemistry Lab I Experiment 2 Quantitation of an unknown protein solution.
Chem 405 Biochemistry Lab I Experiment 2 Quantitation of an unknown protein solution. Introduction: The determination of protein concentration is frequently required in biochemical work. Several methods
INSTRUCTION Probemaker
INSTRUCTION Probemaker Instructions for Duolink In Situ Probemaker PLUS (Art. no. 92009-0020) and Duolink In Situ Probemaker MINUS (Art. no. 92010-0020) Table of content 1. Introduction 4 2. Applications
Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit
Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit Catalog No: E0479r 96 Tests Operating instructions www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH
Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater
Document: AND Sol Env 08 2013 Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater Matrix specific sample preparation and testing methods for environmental waters
AlphaScreen SureFire PDK1 (p Ser241) Assay Kits. Manual
AlphaScreen SureFire PDK1 (p Ser241) Assay Kits Manual Assay Points Catalog # 500 TGRPS500 10 000 TGRPS10K 50 000 TGRPS50K For Laboratory Use Only Research Reagents for Research Purposes Only TGRKV015.13
Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma
Mouse Insulin ELISA For the quantitative determination of insulin in mouse serum and plasma Please read carefully due to Critical Changes, e.g., Calculation of Results. For Research Use Only. Not For Use
QuickZyme Soluble Collagen Assay
QuickZyme Soluble Collagen Assay Version June 2012 FOR RESEARCH USE ONLY NOT FOR USE IN DIAGNOSTIC PROCEDURES This package insert must be read in its entirety before using this product. Introduction Collagen
ab83369 Alkaline Phosphatase Assay kit (Colorimetric)
ab83369 Alkaline Phosphatase Assay kit (Colorimetric) Instructions for use: For the rapid, sensitive and accurate measurement of Alkaline Phosphatase in various samples. This product is for research use
Covalent Conjugation to Cytodiagnostics Carboxylated Gold Nanoparticles Tech Note #105
Covalent Conjugation to Cytodiagnostics Carboxylated Gold Nanoparticles Tech Note #105 Background Gold nanoparticle conjugates have been widely used in biological research and biosensing applications.
Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit
Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit Catalog No. CSB-E15852c (96T) This immunoassay kit allows for the in vitro quantitative determination of canine CK-MB concentrations in serum and plasma.
Data Sheet. PD-L1:B7-1[Biotinylated] Inhibitor Screening Assay Kit Catalog # 72026 Size: 96 reactions
Data Sheet PD-L1:B7-1[Biotinylated] Inhibitor Screening Assay Kit Catalog # 72026 Size: 96 reactions BACKGROUND: There have been a number of studies defining a role for PD-L1 in the regulation of immune
ELISA-VIDITEST-MICROCYSTIN LR Lot: XX
ELISA-VIDITEST-MICROCYSTIN LR Lot: XX Instruction manual PRODUCER : VIDIA Ltd., Nad Safinou II/365, Vestec, 252 42 Jesenice u Prahy, Czech Republic, Tel.: +420261090566 1. TITLE: ELISA-VIDITEST MICROCYSTIN
Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit
Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit Catalog Number. CSB-E14405r For the quantitative determination of rat creatine kinase MM isoenzyme (CK-MM) concentrations in serum, plasma and tissue
MystiCq microrna cdna Synthesis Mix Catalog Number MIRRT Storage Temperature 20 C
microrna cdna Synthesis Mix Catalog Number MIRRT Storage Temperature 20 C Product Description The microrna cdna Synthesis Mix has been designed to easily convert micrornas into cdna templates for qpcr
Cell Cycle Phase Determination Kit
Cell Cycle Phase Determination Kit Item No. 10009349 Customer Service 800.364.9897 * Technical Support 888.526.5351 www.caymanchem.com TABLE OF CONTENTS GENERAL INFORMATION 3 Materials Supplied 3 Safety
RayBio Creatine Kinase (CK) Activity Colorimetric Assay Kit
RayBio Creatine Kinase (CK) Activity Colorimetric Assay Kit User Manual Version 1.0 May 28, 2014 RayBio Creatine Kinase Activity Colorimetric Assay (Cat#: 68CL-CK-S100) RayBiotech, Inc. We Provide You
竞 争 性 分 析 Epitope Mapping 实 验 方 法
竞 争 性 分 析 Epitope Mapping 实 验 方 法 ABSTRACT The simplest way to determine whether two monoclonal antibodies bind to distinct sites on a protein antigen is to carry out a competition assay. The assay can
Human Luteinizing Hormone (LH) Custom Kit
Human Luteinizing Hormone (LH) Custom Kit 18089-v2-2015Jan 1 MSD Toxicology Assays Human Luteinizing Hormone (LH) Custom Kit This package insert must be read in its entirety before using this product.
MLX BCG Buccal Cell Genomic DNA Extraction Kit. Performance Characteristics
MLX BCG Buccal Cell Genomic DNA Extraction Kit Performance Characteristics Monolythix, Inc. 4720 Calle Carga Camarillo, CA 93012 Tel: (805) 484-8478 monolythix.com Page 2 of 9 MLX BCG Buccal Cell Genomic
EnVision Multilabel Plate Readers. Chart Your Course with EnVision the Flagship of its Class
EnVision Multilabel Plate Readers Chart Your Course with EnVision the Flagship of its Class Propel your assays through any Getting to the finish line first is everything in Lead Discovery. That s why we
Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit
Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit Catalog Number. CSB-E14405r For the quantitative determination of rat creatine kinase MM isoenzyme (CK-MM) concentrations in serum, plasma, tissue homogenates.
PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200
3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: 866-667-4362 (905) 227-8848 Fax: (905) 227-1061 Email: [email protected] PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System)
Creatine Kinase Activity Assay Kit (Colorimetric)
ab155901 Creatine Kinase Activity Assay Kit (Colorimetric) Instructions for Use For the sensitive and accurate measurement of Creatine Kinase activity in various samples. This product is for research use
510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY
A. 510(k) Number: K092353 510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY B. Purpose for Submission: This is a new 510k application for a new indication for the MONOLISA Anti-HAV IgM EIA
Lab 10: Bacterial Transformation, part 2, DNA plasmid preps, Determining DNA Concentration and Purity
Lab 10: Bacterial Transformation, part 2, DNA plasmid preps, Determining DNA Concentration and Purity Today you analyze the results of your bacterial transformation from last week and determine the efficiency
Glycolysis Cell-Based Assay Kit
Glycolysis Cell-Based Assay Kit Item No. 600450 www.caymanchem.com Customer Service 800.364.9897 Technical Support 888.526.5351 1180 E. Ellsworth Rd Ann Arbor, MI USA TABLE OF CONTENTS GENERAL INFORMATION
NimbleGen DNA Methylation Microarrays and Services
NimbleGen DNA Methylation Microarrays and Services Sample Preparation Instructions Outline This protocol describes the process for preparing samples for NimbleGen DNA Methylation microarrays using the
Immunoglobulin E (IgE) concentrations in Human. Immunoglobulin E (IgE) Human ELISA Kit
ab108650 Immunoglobulin E (IgE) Human ELISA Kit Instructions for Use For the quantitative measurement of Immunoglobulin E (IgE) concentrations in Human serum. This product is for research use only and
Bovine Vitamin B12 (VB12) ELISA Kit
Bovine Vitamin B12 (VB12) ELISA Kit Catalog Number. CSB-E14089B For the quantitative determination of endogenic bovine vitamin B12 (VB12) concentrations in serum, plasma, tissue homogenates. This package
Rapid GST Inclusion Body Solubilization and Renaturation Kit
Product Manual Rapid GST Inclusion Body Solubilization and Renaturation Kit Catalog Number AKR-110 FOR RESEARCH USE ONLY Not for use in diagnostic procedures Introduction Bacteria are widely used for His
PRODUCT INFORMATION...
VIROMER RED In vitro plasmid DNA and mrna Standard Transfection PRODUCT INFORMATION... 2 GENERAL... 2 RED OR YELLOW?... 3 PROTOCOL GUIDELINES... 4 GENERAL REMARKS... 4 CELL CULTURE AND PLATING... 4 FORWARD/REVERSE
Epinephrine/Norepinephrine ELISA Kit
Epinephrine/Norepinephrine ELISA Kit Catalog Number KA3767 96 assays Version: 01 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Principle of the Assay...
For the rapid, sensitive and accurate measurement of ATP in various samples.
ab83355 ATP Assay Kit (Colorimetric/ Fluorometric) Instructions for use: For the rapid, sensitive and accurate measurement of ATP in various samples. This product is for research use only and is not intended
TECHNICAL BULLETIN. Angiotensin II EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0010 Storage Temperature 20 C
Angiotensin II EIA Kit for serum, plasma, culture supernatant, and cell lysates Catalog Number RAB0010 Storage Temperature 20 C TECHNICAL BULLETIN Product Description The Angiotensin II Enzyme Immunoassay
UltraClean Soil DNA Isolation Kit
PAGE 1 UltraClean Soil DNA Isolation Kit Catalog # 12800-50 50 preps New improved PCR inhibitor removal solution (IRS) included Instruction Manual (New Alternative Protocol maximizes yields) Introduction
Running protein gels and detection of proteins
Running protein gels and detection of proteins 1. Protein concentration determination using the BIO RAD reagent This assay uses a colour change reaction to give a direct measurement of protein concentration.
Molecular Spectroscopy
Molecular Spectroscopy UV-Vis Spectroscopy Absorption Characteristics of Some Common Chromophores UV-Vis Spectroscopy Absorption Characteristics of Aromatic Compounds UV-Vis Spectroscopy Effect of extended
RPCI 004 v.002 Staining Procedure For all Directly Conjugated Reagents (Whole Blood Method)
Immune Tolerance Network RPCI 004 v.002 Staining Procedure For all Directly Conjugated Reagents (Whole Blood Method) Author: Paul Wallace, Director, RPCI Laboratory of Flow Cytometry Approved by: Paul
ab139418 Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis
ab139418 Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis Instructions for Use To determine cell cycle status in tissue culture cell lines by measuring DNA content using a flow cytometer. This
CytoSelect Cell Viability and Cytotoxicity Assay Kit
Product Manual CytoSelect Cell Viability and Cytotoxicity Assay Kit Catalog Number CBA-240 96 assays (96-well plate) FOR RESEARCH USE ONLY Not for use in diagnostic procedures Introduction The measurement
TECHNICAL BULLETIN. FluoroTag FITC Conjugation Kit. Product Number FITC1 Storage Temperature 2 8 C
FluoroTag FITC Conjugation Kit Product Number FITC1 Storage Temperature 2 8 C TECHNICAL BULLETIN Product Description The FluoroTag FITC Conjugation Kit is suitable for the conjugation of polyclonal and
Enzymes: Amylase Activity in Starch-degrading Soil Isolates
Enzymes: Amylase Activity in Starch-degrading Soil Isolates Introduction This week you will continue our theme of industrial microbiologist by characterizing the enzyme activity we selected for (starch
LIVE/DEAD Fixable Dead Cell Stain Kits
USER GUIDE LIVE/DEAD Fixable Dead Cell Stain Kits Pub. No. MAN0002416 (MP34955) Rev. A.0 Table 1. Contents and storage Material Amount Storage Stability Individual Kits: Blue, violet, aqua, yellow-, green,
Chromatin Immunoprecipitation (ChIP)
Chromatin Immunoprecipitation (ChIP) Day 1 A) DNA shearing 1. Samples Dissect tissue (One Mouse OBs) of interest and transfer to an eppendorf containing 0.5 ml of dissecting media (on ice) or PBS but without
How to Biotinylate with Reproducible Results
How to Biotinylate with Reproducible Results Introduction The Biotin Streptavidin system continues to be used in many protein based biological research applications including; ELISAs, immunoprecipitation,
For the development of sandwich ELISAs to measure phosphorylated Epidermal Growth Factor Receptor (EGF R) in cell lysates.
DuoSet IC Human Phospho-EGF R Catalog Number DYC1095-2 Catalog Number DYC1095-5 For the development of sandwich ELISAs to measure phosphorylated Epidermal Growth Factor Receptor (EGF R) in cell lysates.
Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate
Cantaurus, Vol. 7, 5-8, May 1999 McPherson College Division of Science and Technology Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate Janet Bowen ABSTRACT Sulfate is used in
TECHNICAL BULLETIN. Glucagon EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0202 Storage Temperature 20 C
Glucagon EIA Kit for serum, plasma, culture supernatant, and cell lysates Catalog Number RAB0202 Storage Temperature 20 C TECHNICAL BULLETIN Product Description The Glucagon Enzyme Immunoassay (EIA) Kit
Cell Migration, Chemotaxis and Invasion Assay Protocol
Cell Migration, Chemotaxis and Invasion Assay Protocol Hilary Sherman, Pilar Pardo and Todd Upton Corning Life Sciences 900 Chelmsford Street Lowell, MA 01851 Introduction Cell migration, the movement
Mouse glycated hemoglobin A1c(GHbA1c) ELISA Kit
Mouse glycated hemoglobin A1c(GHbA1c) ELISA Kit Catalog Number. CSB-E08141m For the quantitative determination of mouse glycated hemoglobin A1c(GHbA1c) concentrations in lysate for RBC. This package insert
Qualification Study CHO 360-HCP ELISA (Type A to D)
Short Report Qualification Study CHO 360-HCP ELISA (Type A to D) Presented by: http://www.biogenes.de Version 01 Issue date: 27.11.2013 Version 01 Page 1 of 8 Table of Content TABLE OF CONTENT... 2 1 INTRODUCTION...
Toxoplasma gondii IgM ELISA Kit Protocol
Toxoplasma gondii IgM ELISA Kit Protocol (Cat. No.:EK-310-87) 330 Beach Road, Burlingame CA Tel: 650-558-8898 Fax: 650-558-1686 E-Mail: [email protected] www.phoenixpeptide.com Toxoplasma IgM ELISA
Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls
Nitrate DOC316.53.01066 Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific
Development and validation of neutralising anti-drug antibody (Nabs) assays
Development and validation of neutralising anti-drug antibody (Nabs) assays Clare Kingsley Sector Manager, Bioanalytical Sciences, Quotient Bioresearch EBF 2012 Overview Anti-drug antibody and neutralising
Creatine Kinase Activity Colorimetric Assay Kit ABE5487 100 assays; Store at -20 C
Creatine Kinase Activity Colorimetric Assay Kit ABE5487 100 assays; Store at -20 C I. Introduction: Creatine Kinase (CK) also known as creatine phosphokinase (CPK) and ATP: creatine N- phosphotransferase
Western Blot Protocol Protein isolation
Western Blot Protocol Protein isolation A. Preparation of cell lysates. - Preparation of materials: -Dial the microcentrifuge temperature control setting to 4 C -Prepare a bucket of ice -Prepare lysis
CFSE Cell Division Assay Kit
CFSE Cell Division Assay Kit Item No. 10009853 Customer Service 800.364.9897 * Technical Support 888.526.5351 www.caymanchem.com TABLE OF CONTENTS GENERAL INFORMATION 3 Materials Supplied 4 Precautions
Modulating Glucose Uptake in Skeletal Myotubes:
icell Skeletal Myoblasts Application Protocol Introduction Modulating Glucose Uptake in Skeletal Myotubes: Insulin Induction with Bioluminescent Glucose Uptake Analysis The skeletal muscle is one of the
Spectrophotometry Practical Lesson on Medical Chemistry and Biochemistry
Spectrophotometry Practical Lesson on Medical Chemistry and Biochemistry General Medicine Jiřina Crkovská (translated by Jan Pláteník) 2010/2011 1 Spectrophotometry is one of the most widely used instrumental
ab170246 Complement C1q Human ELISA Kit
ab170246 Complement C1q Human ELISA Kit Instructions for Use For the quantitative measurement of Human Complement C1q concentrations in plasma, serum, saliva, urine, milk, cerebrospinal fluid and cell
AxyPrep TM Mag PCR Clean-up Protocol
AxyPrep TM Mag PCR Clean-up Protocol Intro The AxyPrep Mag PCR Clean-up kit utilizes a unique paramagnetic bead technology for rapid, high-throughput purification of PCR amplicons. Using this kit, PCR
Review of Chemical Equilibrium 7.51 September 1999. free [A] (µm)
Review of Chemical Equilibrium 7.51 September 1999 Equilibrium experiments study how the concentration of reaction products change as a function of reactant concentrations and/or reaction conditions. For
FITC Annexin V/Dead Cell Apoptosis Kit with FITC annexin V and PI, for Flow Cytometry
FITC Annexin V/Dead Cell Apoptosis Kit with FITC annexin V and PI, for Flow Cytometry Catalog no. V13242 Table 1. Contents and storage information. Material Amount Composition Storage* Stability FITC annexin
Annexin V Conjugates for Apoptosis Detection
Annexin V Conjugates for Apoptosis Detection Table 1. Spectral characteristics and storage information. Catalog no. Material Annexin V conjugate Amount Ex/Em (nm)* Storage Stability A23202 Alexa Fluor
50 g 650 L. *Average yields will vary depending upon a number of factors including type of phage, growth conditions used and developmental stage.
3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: 866-667-4362 (905) 227-8848 Fax: (905) 227-1061 Email: [email protected] Phage DNA Isolation Kit Product # 46800, 46850 Product Insert
Plant Genomic DNA Extraction using CTAB
Plant Genomic DNA Extraction using CTAB Introduction The search for a more efficient means of extracting DNA of both higher quality and yield has lead to the development of a variety of protocols, however
TransIT -2020 Transfection Reagent
Quick Reference Protocol, MSDS and Certificate of Analysis available at mirusbio.com/5400 INTRODUCTION TransIT -2020 Transfection Reagent is a high-performance, animal-origin free, broad spectrum reagent
ECL Western Blotting Substrate INSTRUCTIONS FOR USE OF PRODUCTS W1001 AND W1015.
Technical Manual ECL Western Blotting Substrate INSTRUCTIONS FOR USE OF PRODUCTS W1001 AND W1015. PRINTED IN USA. 6/09 ECL Western Blotting Substrate All technical literature is available on the Internet
Malondialdehyde (MDA) ELISA
Malondialdehyde (MDA) ELISA For the quantitative determination of MDA in serum, plasma and other biological fluids Cat. No. KT-21493 For Research Use Only. Not for use in diagnostic procedures. Page 1
DNA SPOOLING 1 ISOLATION OF DNA FROM ONION
DNA SPOOLING 1 ISOLATION OF DNA FROM ONION INTRODUCTION This laboratory protocol will demonstrate several basic steps required for isolation of chromosomal DNA from cells. To extract the chromosomal DNA,
HitHunter Assay Kits
Part of GE Healthcare HitHunter Assay Kits If you need: Homogeneity Simplicity Proven technology Versatility Choice of readout HitHunter kits offer: No mixing steps and a limited number of reagent additions.
HiPer Ion Exchange Chromatography Teaching Kit
HiPer Ion Exchange Chromatography Teaching Kit Product Code: HTC001 Number of experiments that can be performed: 5 Duration of Experiment: Protocol: 5-6 hours Storage Instructions: The kit is stable for
PROTEINS (LOWRY) PROTOCOL
1 PROTEINS (LOWRY) PROTOCOL 1. INTRODUCTION The Lowry Assay: Protein by Folin Reaction (Lowry et al., 1951) has been the most widely used method to estimate the amount of proteins (already in solution
INTERFERin in vitro sirna/mirna transfection reagent PROTOCOL. 1 Standard sirna transfection of adherent cells... 2
INTERFERin in vitro sirna/mirna transfection reagent PROTOCOL DESCRIPTION INTERFERin is a powerful sirna/mirna transfection reagent that ensures efficient gene silencing and reproducible transfection in
MULTI-ARRAY. 1-Plate Kit 5-Plate Kit 20-Plate Kit
Meso Scale Discovery MULTI-ARRAY Assay System Mouse/Rat Insulin Kit 1-Plate Kit 5-Plate Kit 20-Plate Kit K152BZC-1 K152BZC-2 K152BZC-3 Meso Scale Discovery Meso Scale Discovery Meso Scale Discovery Meso
LAB 14 ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA)
STUDENT GUIDE LAB 14 ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA) GOAL The goal of this laboratory lesson is to explain the concepts and technique of enzyme linked immunosorbent assay (ELISA). OBJECTIVES
Uscn Life Science Inc. Wuhan
Uscn Life Science Inc. Wuhan Website: www.uscnk.com Phone: +86 27 84259552 Fax: +86 27 84259551 E-mail: [email protected] ELISA Kit for Human Creatine Kinase,Mitochondrial 1A (CKMT1A) Instruction manual
