Freshen up. our air. ventilation catalogue
|
|
|
- Wilfred Carr
- 9 years ago
- Views:
Transcription
1 Freshen up our air ventilation catalogue
2 Daikin Europe N.V. ABOUT DAIKIN Daikin has a worldwide reputation based on almost 85 years experience in the successful manufacture of high quality air conditioning equipment for industrial, commercial and residential use. Daikin quality Daikin s much envied quality quite simply stems from the close attention paid to design, production and testing as well as aftersales support. To this end, every component is carefully selected and rigorously tested to verify its contribution to product quality and reliability. ENVIRONMENTAL AWARENESS Air Conditioning and the Environment Air conditioning systems provide a significant level of indoor comfort, making optimum working and living conditions possible in the most extreme climates. In recent years, motivated by a global awareness of the need to reduce the burdens on the environment, Daikin has invested enormous efforts in limiting the negative effects associated with the production and the operation of air conditioners. Hence, models with energy saving features and improved eco-production techniques have seen the light of day, making a significant contribution to limit the impact on the environment. 2 This sign highlights features where Daikin has invested into technologies to reduce the impact of air conditioning on the environment. This sign can be found on pages:
3 HRV - Heat Reclaim Ventilation 7 Benefits for building owners 8 1 Energy energy saving ventilation 8 2 Reduces the load on the air conditiong system 9 3 Free cooling 9 Benefits for design offices and consultants 10 1 Total solution concept 10 2 Slim design 10 3 High static pressure 10 4 Wide range of units 10 5 Wide operation range 10 Benefits for installers 11 1 Simple design and construction 11 2 Filter cleaning 11 3 High static pressure 11 Benefits for end users 12 1 Create a high quality indoor environment 12 2 Fresh up operation 13 3 Low operation sound level 13 4 Individual control via HRV remote control 13 Specifications 14 VAM-Fa 14 VKM-gm 15 VKM-g 16 accessories 17 FXMQ-MF outdoor air processing unit 19 Benefits % fresh air intake possible 20 2 Leaves maximum floor and wall space for Furniture, decoration and fittings 20 3 Wide operation range 20 4 High static pressure 20 5 Built-in drain pump 20 Connenction conditions 20 Specifications 21 accessories 21 User friendly control SystemS 23 1 Interlock of the ventilation operation with the air conditioner operation 23 2 Super wiring System 23 Overview of control systems 24 1 Individual Control Systems 26 2 Centralised Control Systems 28 ERQ (pair) AND VRV Air Handling Applications 31 Benefits 31 1 High efficiency 31 2 High comfort levels 31 3 Easy design and installation 31 4 Total solution concept 31 Which system offers me the best solution? 32 1 I only need a connection to an air handling unit 32 2 I need an air handling unit and heating, and/or cooling 32 System overview 33 Control possibilities 34 Selection of air handling units 36 1 Pair application 36 2 Multi application 37 Specifications 38 3
4 Which system offers me the best solution? With the advent of new building regulations, greater awareness of increasing energy costs and a responsibility towards environmental issues, modern commercial spaces are insulated better than ever. Double glazing, thicker roof insulation and draught excluders of course, help considerably towards reducing heating/cooling demand and burdens on the environment. The down-side however, is that these same commercial spaces have now become, in effect, sealed boxes with little or no replenishment of the air. Daikin offers a variety of solutions for the provision of fresh air ventilation to offices, hotels, stores and other commercial outlets each one complementary to and as flexible as both Sky Air and VRV systems themselves. Heat Reclaim Ventilation Proper ventilation is a key component of climate control in buildings, offices and shops. In its basic function, it ensures a flow of incoming fresh air and outgoing stale air. Our HRV (heat reclaim ventilation) solution can do much more. It can recover heat and OPTIMISE THE BALANCE BETWEEN INDOOR AND OUTDOOR TEMPERATURE AND HUMIDITY, thus reducing the load on the system and increasing efficiency. Outdoor Air Processing in a single unit Our FXMQ-MF air processing solution uses heat pump technology to COMBINE FRESH AIR TREATMENT AND AIR CONDITIONING IN A SINGLE SYSTEM, thereby eliminating the usual design problems associated with balancing air supply and discharge. Total system cost is reduced and design flexibility enhanced because the indoor air conditioning fan coil units and an outdoor air treatment unit can be connected to the same refrigerant line. erq (pair) and VRV air handling applications For small, medium and large commercial spaces, we offer a range of R-410A inverter condensing units that provide air handling and air conditioning. This approach combines the flexibility of our ERQ and VRV units with Air Handling Applications, resulting in a simple, reliable design for OPTIMUM CONTROL OF INDOOR AIR QUALITY AND MAXIMUM EFFICIENCY.
5 overview ventilation range Ventilation: provision of fresh air 1 2 Humidification: optimise the balance between indoor and outdoor humidity Air processing: optimise the balance between indoor and outdoor fresh air temperature 3 Type name Components of indoor air quality Air flow rate (m 3 /h) ,000 1,500 2,000 4,000 6,000 8,000 VAM-FA Ventilation Heat Reclaim Ventilation VKM-G Ventilation 3 Air processing VKM-GM Ventilation 2 Humidification 3 Air processing OUTDOOR AIR PROCESSING UNIT 1 FXMQ-MF Ventilation 3 Air processing ERQ AND VRV AIR HANDLING APPLICATIONS 2 EKEXV-kit Ventilation 3 Air processing 1 Not connectable to VRVIII-S (RXYSQ-PAV, RXYSQ-PAY) 2 Air flow rate is a calculated indication only, based on the following values: heating capacity EKEXV-kit * 200m³/h
6 6
7 HRV - Heat reclaim ventilation Ventilation, humidification & air processing HRV helps to create a high quality indoor environment The Daikin HRV (Heat Reclaim Ventilation) unit recovers heat energy lost through ventilation and maintains a comfortable and clean indoor environment without changes in room temperature. This also reduces the load on the air conditioning system and saves energy. In addition, the HRV interlocks with Daikin s air conditioning systems (for example VRV and Sky Air) and automatically switches over to ventilation mode when needed, further increasing the effects of energy conservation. HRV can be integrated on the air conditioner remote control allowing total control over air conditioning and ventilation via a simple configuration. The current line-up includes models with or without DX coil and/or humidifier. The DX coil helps to prevent the direct impact of cold airflow upon persons during the heating cycle and vice versa, the humidifier optimises the balance between indoor and outdoor humidity. Finally high static pressure enhances design flexibility. 7
8 benefits for building owners Energy saving ventilation Buildings need year round ventilation. In traditional ventilation systems the conditioned inside air is lost when exhausted externally and new unconditioned air is brought into the building. This results in large amounts of air being heated up or cooled down over and above the actual load of the air conditioning system and leads to a substantial waste of energy. The Daikin HRV system however, automatically balances outside and inside temperature and humidity enabling the recovery of heat/cold with significant savings in running costs. Specially developed HEP element The heat exchange element uses a high efficiency paper (HEP) possessing superior moisture absorption and humidifying properties. The heat exchange unit rapidly recovers heat contained in latent heat (vapour). The element is made of a material with flame resistant properties and is treated with an anti-moulding agent. Operation of the high effiency paper. Outdoor Indoor 30.6 C 62% RH 32 C 70% RH SA 27.4 C 63% RH RA 26 C 50% RH Temperature and humidity SA Integrallyformed liner RA Integrally-formed liner RH: Relative Humidity SA: Supply Air (to room) RA: Return Air (from room) 8
9 Reducing the load on the air conditioning system Thanks to the use of heat reclaim ventilation the load on the air conditioning is reduced with approximately 31%. - 23% by operating in total heat exchange mode (in comparison with normal ventilation fans) - another 6 % by auto-ventilation mode changeover switching - a further 2 % by pre-cool, pre-heat control (reduces air conditioning load by not running the HRV shortly after the air conditioning is switched on.) Note: the values mentioned above may vary according to weather and other environmental conditions at the location of the unit s installation Operation automatically switches to the optimum pattern to suit prevailing conditions Air conditioning in cooling Heat exchanger Exhaust fan Damper element (heat recovery) Air conditioning off In between (bypass ventilation) Air conditioning in heating Heat exchanger element (heat recovery) EA OA RA EA Automatic changeover SA OA RA EA Automatic changeover SA OA RA SA Air supply fan DX coil (cooling) DX coil (heating) Humidifying Example: Outdoor temp. 30 C Indoor temp. 22 C Example: Outdoor temp. -5 C Indoor temp. 22 C EA: exhaust air OA: outdoor air RA: return air (from room) SA: supply air (to room) Free cooling The free cooling option reduces the air conditioning energy consumption and uses energy in a more efficient way by actively introducing fresh air into rooms. Free cooling maintains indoor comfort through the introduction of low temperature outdoor air into rooms. Note: Free cooling is only available in combination with Intelligent Touch Controller Temp. C Set temp. Temp. C Morning 16 Free cooling possible Free cooling possible Example of free cooling during summer Morning Day time Day time Night Outdoor temp. Night Nighttime free cooling operation Nighttime free cooling operation is an energy saving function operating at night when the air conditioning is switched off. By ventilating rooms containing office equipment that increases room temperature, night purge reduces the cooling load when air conditioning is switched on in the morning, reducing the daily running costs. Set 21 temp. 19 Temp Outdoor Temp. Setting Temp. Indoor Temp. Outdoor temp % free cooling possible Example of free cooling during intermediate season Nighttime free cooling operation is factory set to off but can be activated by your Daikin dealer on request. Nighttime free cooling operation only available on VKM units connected to a VRV system VKM Air Conditioner 20 on off on off 2 Hours auto start start 9
10 benefits for design offices AND consultants Total solution concept - integrated ventilation The integration of ventilation into a total building climate system, such as the VRV system, offers numerous advantages. Daikin supplies software which simulates the working of the entire system, simplifying its design and presenting an ideal solution for the building itself and a one-stop solution for the client. As well as design benefits, it also simplifies project follow-up, installation and subsequent commissioning and maintenance since only one party is involved. Finally, the end user benefits from interlocking ventilation with air conditioner operation by virtue of greatly simplified overall system control. Note: more information on integrated control can be found in the control systems chapter Slim Design The slim design of the HRV unit enables it to be mounted in narrow ceiling voids and irregularly shaped spaces. 285mm Installation under the floor of a small building Installation under a beam Installation in an irregular space VAM250FA Higher static pressure and reduced noise The use of multiple, overlapping arc shaped fan blades makes it possible to optimize the chord lenght and blade outlet angle. High Static Pressure External static pressure (ESP) up to 160 Pa facilitates the use with flexible ducts of varying lengths. Rotating currents for reduced loss The use of a thinner scroll allows rectification of rotating currents within the scroll. Higher static pressure Thanks to wide fan diameter and optimized blade width Higher static pressure and reduced pressure loss α In addition to increasing the scroll wrap angle and boosting the static pressure, the outflow angle has been optimized. θ Wide range of units 10 The wide Daikin unit range ensures correct equipment design and sizing.
11 Wide operation range The HRV unit can be installed in practically any location. The standard operation range (outdoor temperature) is from -15 C to 40 CDB (50 CDB for VAM units) and can be extended down to -25 C if a pre heater is installed VAM Cooling 50 CDB VKM Cooling 40 CDB 1 Contact your local dealer for more information and restrictions CDB with optional preheater -15 CDB with optional preheater CDB -25 CDB benefits for installers Simple Design and Construction Switch box Horizontal installation Access door Maintenance cover Upside down installation The unit can be installed either horizontally or upside down always allowing easy access for inspection and maintenance. A 450 mm square inspection hatch enables maintenance and heat exchange element replacement to be performed with ease. Also no drain connection is needed, further simplifying the installation. Filter Cleaning A signal on the remote control indicates when the air filter needs cleaning. 11
12 benefits for end users Creating a high quality indoor environment In addition to the HEP high efficiency paper, VKM models contain a DX-coil and humidifier (VKM only), thereby balancing the incoming fresh air with indoor temperature and humidity and ensuring the best possible indoor environment. Heating and cooling + Heat recovery + Humidifying Effect of full heat exchange Effect of cooling Indoor temperature during cooling Indoor temperature during heating 60 Outdoor air temperature in summer 40 Effect of humidification 20 Relative humidity (%) Outdoor air temperature in winter Effect of of heating Effect Effect of of full full heat exchange Dry bulb temperature ( CDB) Operation of humidicicaton and air processing in heating mode (VKM-GM) Exhaust Fan Heat Exchanger Elements Damper Motor EA (Exhaust air to outdours) Damper DX coil (Direct expansion coil) OA (Fresh air from outdoors) RA (Return air from room) Air Supply Fan SA (Supply air to room) Electronics Box (Control box) Humidifier element: Float switch Solenoid valve Utilizing the principle of capillary action, water is permeated throughout the humidifier element. The heated air from the DX coil passes through the humidifier and absorbs the moisture. AIRFLOW SA water Drain pan Drain 12
13 Fresh-Up Operation The user can select 2 fresh-up modes via the remote control for a more comfortable air environment. 1. Supply rich mode: 2. Exhaust fresh-up: Raising the air supply maintains proper room pressure to prevent back-flow of toilet/kitchen odours or moisture inflow. Raising exhaust air decreases room pressure to prevent the leaking of odours or floating bacteria into other rooms. Portion of fresh-up operation Air exhaust HRV Normal ventilation fan Air exhaust Air supply HRV Floor area Air supply Portion of exhaust operation Sick room eg. Office eg. Hospital low operation sound level Continues research by Daikin into reducing operation sound levels has resulted in sound pressure levels down to 20.5dBA (VAM150FA) Daikin indoor units dba Perceived loudness Sound 0 Treshold of hearing - 20 Extremely soft Rustling leaves 40 Very soft Quiet room 60 Moderately loud Normal conversation 80 Very loud City traffic noise 100 Extremely loud Symphonic orchestra 120 Threshold of feeling Jet taking off Dust Prevention When the HRV is operating independently, the fan in an interlocked indoor unit continues turning, so dust does not fall from the air filter. Systems without dust prevention With Daikin HRV OFF Dust Blowing mode No dust is blown out 13
14 VAM-FA Heat reclaim ventilation VAM800FA SPECIFICATIONS VENTILATION VAM150FA8VE VAM250FA8VE VAM350FA8VE VAM500FA8VE VAM650FA8VE VAM800FA8VE VAM1000FA8VE VAM1500FA8VE VAM2000FA8VE Power input - 50Hz Power input - 60Hz heat exchange mode bypass mode heat exchange mode bypass mode nom. nom. nom. nom. ultra high/ high/low kw 0.116/ 0.100/0.056 ultra high/ high/low kw 0.116/ 0.100/0.056 ultra high/ high/low kw 0.117/ 0.099/0.056 ultra high/ high/low kw 0.117/ 0.099/ / 0.112/ / 0.112/ / 0.119/ / 0.119/ / 0.175/ / 0.175/ / 0.214/ / 0.214/ / 0.189/ / 0.189/ / 0.232/ / 0.232/ / 0.325/ / 0.325/ / 0.384/ / 0.384/ / 0.400/ / 0.400/ / 0.471/ / 0.471/ / 0.432/ / 0.432/ / 0.537/ / 0.537/ / 0.758/ / 0.758/ / 0.929/ / 0.929/ / 0.767/ / 0.767/ / 1.021/ / 1.021/0.779 Temperature exchange efficiency - ultra high % Hz Enthalpy exchange efficiency - cooling ultra high % Hz Operation mode Heat exchange mode / Bypass mode / Fresh-up mode Heat exchange system Air to air cross flow total heat (sensible + latent heat) exchange Heat exchange element Specially processed non-flammable paper Casing material Galvanised steel plate Dimensions unit heightxwidthxdepth mm 285x776x x828x x1,004x x1,004x1, x1,514x x1,514x1,156 Weight unit kg type Sirocco fan Fan air flow rate - 50hz air flow rate - 60hz external static pressure - 50hz heat exchange ultra high/ mode/bypass mode high/low kw 150/ 150/110 heat exchange ultra high/ mode/bypass mode high/low kw 150/ 150/ / 250/ / 250/ / 350/ / 350/ / 500/ / 500/ / 650/ / 650/ / 800/ / 800/670 1,000/ 1,000/870 1,000/ 1,000/800 1,500/ 1,500/1,200 1,500/ 1,500/1,200 2,000/ 2,000/1,400 2,000/ 2,000/1,400 ultra high/high/low Pa 69/39/20 64/39/20 98/70/25 98/54/25 93/39/25 137/98/49 157/98/78 137/98/49 137/78/59 external static ultra high/high/low Pa 98/54/24 98/54/20 142/85/15 147/54/20 162/69/34 225/118/69 196/108/69 206/118/69 196/88/69 pressure - 60hz Fan motor output 50 hz W Sound pressure level - 50Hz heat exchange mode ultra high/high/low dba bypass mode ultra high/high/low dba 27 / 28.5/26 / 27.5/20.5 / / 28.5/26.5 / 27.5/20.5 / / 29/26 / 27/21 / / 29/27 / 28/21 / / 34/31.5 / 33/23.5 / / 34.5/31.5 / 34.5 / 35.5/33 / 36 / 37/34.5 / 33/24.5 / /27 / 28 36/31 / / 34/31 / 33.5 / 34.5/32.5 / 34.5 / 35.5/34 / 36 / 37/34.5 / 32.5/24.5 / /25.5 / /27 / /31 / / 37/35 / 36/31 / / 37/35.5 / 36/31 / / 41.5/38 / 39/34 / / 41.5/38 / 39/33.5 / / 42.5/38 / 41/35 / / 42.5/38 / 41/35 / 37 Sound pressure heat exchange mode ultra high/high/low dba 28.5/26.5/ /26/ /32/22 34/31/24 36/33/27 37/35/ /38/33 41/38/35 level - 60Hz bypass mode ultra high/high/low dba 28/27/20 29/27/ /33/22 35/33/ /34/27 37/35/ /38/33 41/38/35 min. CDB -15 Operation range max. CDB 50 relative humidity % 80% or less Connection duct diameter mm Piping connections drain - Insulation material Self-extinguishable urethane foam Power supply phase/frequency/voltage Hz/V 1~/50/60/ /220 (1) Operation sound is measured at 1.5m below the center of the body. (2) Normal amplitude, input and efficiency depend on the mentioned conditions. (3) Sound values are measured in an anechoic chamber. Operating sound level generally becomes higher than this value depending on the operating conditions, reflected sound, and peripheral noise. (4) The specifications, designs and information here are subject to change without notice. 14
15 VKM-G Heat reclaim ventilation, air processing and humidification VKM80-100G SPECIFICATIONS VENTILATION VKM50G VKM80G VKM100G Power input - 50Hz Fresh air conditioning load heat exchange mode bypass mode nom. nom. ultra high/ high/low kw 0.560/ 0.490/0.420 ultra high/ high/low kw 0.560/ 0.490/ / 0.560/ / 0.560/ / 0.570/ / 0.570/0.480 cooling kw 4.71 (2) 7.46 (2) 9.12 (2) heating kw 5.58 (3) 8.79 (3) (3) Temperature exchange ultra high efficiency - 50Hz % Enthalpy exchange efficiency - 50Hz cooling ultra high % Operation mode Heat exchange mode / Bypass mode / Fresh-up mode Heat exchange system Air to air cross flow total heat (sensible + latent heat) exchange Heat exchange element Specially processed non-flammable paper Casing material Galvanised steel plate Dimensions unit heightxwidthxdepth mm 387x1,764x x1,764x1,214 Weight unit kg rows quantity 2 Heat exchanger stages quantity 12 fin pitch mm 2.2 face area m² type Sirocco fan Fan air flow rate - 50hz heat exchange mode/bypass mode ultra high/ high/low kw 500/ 500/ / 750/ / 950/820 external static pressure - 50hz ultra high/high/low Pa 180/150/ /120/80 150/100/70 Fan motor output 50 hz W 280 Sound pressure level - 50Hz heat exchange mode bypass mode ultra high/ high/low ultra high/ high/low dba 38 / 38.5 / 39/36 / 36.5 / 37/33.5 / 34.5 / / 41 / 41.5/37.5 / 38 / 39/34.5 / 36 / / 40.5 / 41/38 / 38.5 / 39/35 / 36 / 36.5 dba 38 / 38.5 / 39/36 / 36.5 / 37/33.5 / 34.5 / / 41 / 41.5/37.5 / 38 / 39/34.5 / 36 / / 40.5 / 41/38 / 38.5 / 39/35 / 36 / 36.5 around unit CDB 0 C~40 CDB, 80% RH or less Operation range supply air CDB -15 C~40 CDB, 80% RH or less return air CDB 0 C~40 CDB, 80% RH or less Refrigerant control Electronic expansion valve Connection duct diameter mm liquid type/od mm Flare connection/6.35 Piping gas type/od mm Flare connection/12.7 connections drain PT3/4 external thread Insulation material Self-extinguishable urethane foam Power supply phase/frequency/voltage Hz/V 1~/50/ (1) Cooling and heating capacities are based on the following conditions: Fan is based on High and Ultra High. The figures in parenthesis indicate the heat reclaimed from the heat recovery ventilator. When calculating the capacity as indoor units, use 3.5kW. (2) Cooling: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB (3) Heating: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB (4) OA: fresh air from outdoors, RA: return air from the room (5) The specifications, designs and information here are subject to change without notice. (6) Cooling and heating capacities are based on the following conditions: Fan is based on High and Ultra High. The figures in parenthesis indicate the heat reclaimed from the heat recovery ventilator. When calculating the capacity as indoor units, use 5.6kW. (7) Cooling and heating capacities are based on the following conditions: Fan is based on High and Ultra High. The figures in parenthesis indicate the heat reclaimed from the heat recovery ventilator. When calculating the capacity as indoor units, use 7.0kW. 15
16 VKM-GM Heat reclaim ventilation and air processing VKM80-100GM SPECIFICATIONS VENTILATION VKM50GM VKM80GM VKM100GM Power input - 50Hz Heat exchange mode Bypass mode Nom. Nom. Ultra high/ High/Low kw 0.560/ 0.490/0.420 Ultra high/ High/Low kw 0.560/ 0.490/ / 0.560/ / 0.560/ / 0.570/ / 0.570/0.480 Fresh air Cooling kw 4.71 (2) 7.46 (2) 9.12 (2) conditioning Heating kw 5.58 (3) 8.79 (3) (3) load Temperature Ultra high % exchange efficiency Hz Enthalpy Cooling Ultra high % exchange efficiency - 50Hz Operation mode Heat exchange mode / Bypass mode / Fresh-up mode Heat exchange system Air to air cross flow total heat (sensible + latent heat) exchange Heat exchange element Specially processed non-flammable paper Humidifier System Natural evaporating type Casing Material Galvanised steel plate Dimensions Unit HeightxWidthxDepth mm 387x1,764x x1,764x1,214 Weight Unit kg Rows Quantity 2 Stages Quantity 12 Heat exchanger Fin pitch mm 2.2 Face area m² Type Sirocco fan Fan Air flow rate - Heat exchange ultra high/ mode/bypass 50Hz mode high/low kw 500/ 750/ 950/ 500/ / /820 External static pressure - 50Hz Ultra high/high/low Pa 160/120/ /90/70 110/70/60 Fan motor Output 50 Hz W 280 Sound pressure Heat exchange mode Ultra high/high/low dba 37 / 37.5 / 38/35 / 35.5 / 36/32 / 33 / / 39 / 40/36 / 37 / 37.5/33 / 34 / / 39.5 / 40/37 / 37.5 / 38/34 / 34.5 / 35.5 level - 50Hz Bypass mode Ultra high/high/low dba 37 / 37.5 / 38/35 / 35.5 / 36/32 / 33 / / 39 / 40/36 / 37 / 37.5/33 / 34 / / 39.5 / 40/37 / 37.5 / 38/34 / 34.5 / 35.5 Around unit CDB 0 C~40 CDB, 80% RH or less Operation Supply air CDB -15 C~40 CDB, 80% RH or less range Return air CDB 0 C~40 CDB, 80% RH or less Refrigerant Control Electronic expansion valve Connection duct diameter mm Piping connections Liquid Type/OD mm Flare connection/6.35 Gas Type/OD mm Flare connection/12.7 Water supply mm 6.4 Drain PT3/4 external thread Self-extinguishable urethane foam Insulation material Power supply Phase/Frequency/Voltage Hz/V 1~/50/ (1) Cooling and heating capacities are based on the following conditions: Fan is based on High and Ultra High. The figures in parenthesis indicate the heat reclaimed from the heat recovery ventilator. When calculating the capacity as indoor units, use 3.5kW. (2) Cooling: indoor temp. 27 CDB, 19.0 CWB; outdoor temp. 35 CDB (3) Heating: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB (4) Humidifying capacity: indoor temp. 20 CDB, 15 CWB; outdoor temperarure 7 CDB, 6 CWB (5) Operation sound measured at 1.5m below the center of the unit is converted to that measured in an anechoic chamber, built in accordance with JIS C1502 condition. (6) The actual operation sound varies depending on the surrounding conditions (near running unit s sound, reflected sound etc.) and is normally higher than this value. (7) The sound level at the air discharge port is about 8-11dB higher than operating sound of the unit. For operation in a quiet room, it is required to take measures to lower the sound, for example install more than 2m soft duct near the air discharge grille. (8) Normal amplitude, input and efficiency depend on the mentioned conditions. (9) OA: fresh air from outdoors, RA: return air from the room (10) The specifications, designs and information here are subject to change without notice. (11) Cooling and heating capacities are based on the following conditions: Fan is based on High and Ultra High. The figures in parenthesis indicate the heat reclaimed from the heat recovery ventilator. When calculating the capacity as indoor units, use 5.6kW. (12) Cooling and heating capacities are based on the following conditions: Fan is based on High and Ultra High. The figures in parenthesis indicate the heat reclaimed from the heat recovery ventilator. When calculating the capacity as indoor units, use 7.0kW.
17 Accessories Silencer Duct adapter OTHERS VAM150FA VAM250FA VAM350FA VAM500FA VAM650FA VAM800FA VAM1000FA VAM1500FA VAM2000FA VKM50GA(M) VKM80-100GA(M) YAFM323F15 YAFM323F25 YAFM323F35 KDDM24A50 KDDM24A100 KDDM24A100 2 x KDDM24A100 KAF241G80M KAF241G100M High efficiency filter -65% KAF242G80M KAF242G100M -90% Replacement long life filter YAFF323F15 YAFF323F25 YAFF323F35 YAFF323F50 YAFF323F65 YAFF323F100 2 x YAFF323F65 2 x YAFF323F100 Filter chamber 1 Silencer KDDM24B100 Nom. piping diameter Ø250mm Duct adapter YAFF323F50 YAFF323F65 YDFA25AEI Nom. piping diameter Ø250mm Notes (1) Filter chamber has a suction-type flange. (Main unit does not). Some options may not be usable due to the equipment installations conditions. Please conrfirm prior to ordering. Some options may not be used in combination. Operating sound may increase somewhat depending on the options used. INDIVIDUAL CONTROL SYSTEMS VAM-FA VKM-GA(M) Wired remote control BRC1E52A / BRC1D52 BRC1E52A / BRC1D52 VAM wired remote control BRC301B61 BRC301B61 CENTRALISED CONTROL SYSTEMS VAM-FA VKM-GA(M) Centralised remote control DCS302C51 DCS302C51 Unified ON/OFF control DCS301B51 DCS301B51 Schedule timer DST301B51 DST301B51 OTHERS VAM-FA VKM-GA(M) Wiring adapter for electrical appendices (control and monitoring F1 F2) KRP2A51 KRP2A51 Wiring adapter for electrical appendices (control and monitoring P1 P2) - - Adapter for humidifier (running ON signal output) KRP50-2 KRP50-2 Adapter for heater control kit BRP4A50 BRP4A50 Remote sensor - - Notes (1) Cool/heat selector required for operation (2) Do not connect the system to DIII-net devices (Intelligent controller, Intelligent Manager, LonWorks interface, BACnet interface ). 17
18
19 FXMQ-MF - Outdoor Air Processing Unit Ventilation & air processing Combined fresh air treatment and air conditioning via a single system Both fresh air treatment and air conditioning can be achieved successfully in a single system via heat pump technology. This without the usual design problems associated with balancing air supply and discharge. Air conditioning indoor units and an outdoor air processing units can be connected to the same refrigerant circuit, resulting in enhanced design flexibility and a significant reduction in total system costs. 19
20 benefits 100% Fresh Air Intake Possible Outdoor air processing units can be used exclusively to provide 100% fresh air into the building. Even if only partly used the system reduces the load on the air conditioner by adjusting the outdoor air temperature via fixed discharge temperature control. Leaving maximum floor and wall space for Furniture, decoration and fittings Wide operation range The outdoor air processing unit can be installed practically anywhere. The unit operates at outdoor ambients up to 43 C in cooling mode and down to -5 C in heating mode. High static pressure External static pressure (ESP) up to 225 Pa allows the use of extensive ductwork runs and facilitates the use with flexible ducts of varying lengths. Ideal for use in large areas C FXMQ-MF 43 C Built-in drain pump A drain pump kit increases the reliability of the drain system 1 1 Drain pump kit available as accessory Connection Conditions The total connected capacity of the standard indoor units and fresh air treatment units must be between 50% and 100% of the capacity of the air conditioning outdoor units. The connected capacity of the fresh air treatment units must not exceed 30% of the capacity of the air conditioning outdoor units. A fresh air treatment unit can also be used exclusively. The connected capacity of the fresh air treatment unit must be between 50% and 100% of the capacity of the air conditioning outdoor unit. Connectable outdoor units: - VRVIII Heat pump Optimised for heating (RTSYQ) - VRVIII Heat pump High COP combination (RXYHQ) - VRVIII Heat pump Small footprint combination (except 5HP unit) (RXYQ) 20HP VRV III Series Outdoor Units Outdoor Air processing Unit Outdoor Air Processing unit 5HP Indoor Unit Indoor Unit 3x 5HP Indoor Unit Air Conditioning Outdoor Air Supply 20
21 FXMQ-MF Specifications 125, 200, 250 Outdoor air processing unit, ventilation and air processing FXMQ MF SPECIFICATIONS VENTILATION FXMQ125MF FXMQ200MF FXMQ250MF Capacity cooling kw heating kw Power input cooling kw heating kw Casing material Galvanised steel Dimensions unit height x width x depth mm 470x744x1, x1,380x1,100 Weight unit kg rows quantity 3 Heat exchanger stages quantity 26 fin pitch mm 2.0 face area m² Fan type Sirocco fan air flow rate - 50hz heat exchange mode/bypass mode Fan motor model D13/4G2DA1 Refrigerant type R-410A Refrigerant control Electronic expansion valve liquid type/od mm Flare connection/9.52 Piping gas type/od mm Flare connection/15.9 Braze connection/19.1 connections drain PS1B Braze connection/22.2 Power supply phase/frequency/voltage Hz/V 1~/50/ (1) Cooling: outdoor temp.: 33 CDB, 28 CWB (68%RH), discharge set temperature: 18 CDB, equivalent piping length 7.5m (horizontal) (2) Heating: outdoor temp. 0 CDB, -2.9 CWB (50%RH); discharge set temp. 25 CDB; equivalent piping length: 7.5m (horizontal) (3) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (4) The air filter is not a standard accessory, but please mount it in the duct system of the suction side. Select its colorimetric method (gravity method) 50% or more. (5) When connected to VRV water-cooled outdoor units a mix of ventilation units and VRV indoor units is not possible ACCESSORIES OTHERS FXMQ125MF FXMQ MF High efficiency filter -65% KAFJ372L140-90% KAFJ373L140 Replacement long life filter KAFJ371L140 KAFJ371L280 Filter chamber 1 KDJ370SL140 KDJ370SL280 Drain pump kit KDU30LL250VE Adapter for wiring KRP1B61 Notes (1) Filter chamber has a suction-type flange. (Main unit does not). Some options may not be usable due to the equipment installations conditions. Please conrfirm prior to ordering. Some options may not be used in combination. Operating sound may increase somewhat depending on the options used. INDIVIDUAL CONTROL SYSTEMS Wired remote control FXMQ-MF BRC1E52A / BRC1D52 CENTRALISED CONTROL SYSTEMS Centralised remote control Unified ON/OFF control Schedule timer FXMQ-MF DCS302C51 DCS301B51 DST301B51 OTHERS Wiring adapter for electrical appendices (control and monitoring F1 F2) Wiring adapter for electrical appendices (control and monitoring P1 P2) FXMQ-MF KRP2A61 KRP4A51 21
22 22
23 user friendly CONTROL SYSTEMS Interlock of the ventilation operation with the air conditioner operation Interlock of the ventilation operation with the air conditioner operation greatly simplifies overall system control. The same remote control centralizes air conditioning and ventilation operations, obviating any need for ventilation remote control installation work. Using a centralized remote control also frees the user to choose from a wide range of control systems that integrate air conditioning and ventilation. By incorporating a variety of centralized control equipment, the user can build a large, high grade centralized control system. 1 Linked control of FXMQ-MF and HRV is not supported VRV indoor unit ON/OFF signal Cooling/Heating mode signal Set temperature signal Ventilation signal Humidifier ON/OFF signal Interlocking Operating mode signal Filter cleaning signal Faillure detection signal HRV Super Wiring System A Super Wiring system is used to enable the shared use of wiring between indoor units, outdoor units and the centralised remote control. This system makes it easy for the user to retrofit the existing system with a centralised remote control, simply by connecting it to the outdoor units. Thanks to a non polarity wiring system, incorrect connections become impossible and installation time is reduced. Indoor unit VKM Wired remote control Outdoor unit 23
24 Overview of control systems Individual Control Systems 5 individual control systems give the user control over the VRV system and the combined ventilation. BRC1D52 and are wired remote controllers, giving access to room temperature settings, schedule timer, Next to that they also have user friendly HRV functions. BRC301B61 is a wired controller especially designed for VAM units. BRC2C51 and BRC3A61 are compact, easy to use remote controllers, ideal for use in hotel bedrooms. VAM remote control BRC301B61 Wired remote control Wired remote control BRC1D52 Centralised control systems By combining the (optional) centralised control equipment listed below, the user can achieve a wide range of comprehensive centralised control systems for air conditioning and ventilation. Centralised remote control DCS302C51 Unified ON/OFF control DCS301B51 Schedule timer DST301B51 Network solutions HRV and the Outdoor Air Processing unit are connectable to all current Daikin network solutions: Basic solution for control and management of up to 2,000 indoor units (Sky Air and VRV). Allows detailed and easy monitoring and operation of VRV systems (maximum 2 x 64 control groups). LonWorks Interface BACnet Interface The ideal solution for full control and management of maximum 1,024 VRV indoor units. Open network integration of VRV monitoring and control functions into LonWorks networks. Integrated control system for seamless connection between VRV and BMS systems. 24 For more information consult the Daikin controls systems brochure or contact your local dealer
25 DESCRIPTION HRV FXMQ-MF VAM remote control BRC301B61 - Wired air conditioner remote control BRC1D52 / Centralised remote control DCS302C51 Unified on/off control DCS301B51 Schedule timer DST301B51 DS net adapter DTA113B51 Intelligent touch controller DCS601C51 Intelligent Manager DAM602B51/B52 LonWorks interface DMS504B51 BACnet interface DMS502A51 Wiring adapter for electrical appendices (1) KRP2A61 Wiring adapter for electrical appendices (2) - KRP4A51 25
26 BRC1D52 Individual Control Systems Control up to 16 indoor units or 8 HRV units (1group) Easy to use: all main functions directly accessible Easy setup: improved graphical user interface for advanced menu settings Simultaneous ON/OFF of HRV and air conditioner (BRC1D52/) Airflow rate switching (initial setting) Ventilation mode switching (initial setting) Self diagnostic functions Filter sign display and reset Timer settings, simultaneous control with air conditioner (BRC1D52/) ON/OFF of VAM (BRC301B61) Independent operation of HRV Timer settings (BRC301B61) Fresh-up mode switching (HRV only) (Selectable: supply rich mode, exhaust rich mode; initial setting) Notes: The remote control wired to the FXMQ-MF cannot be set as master remote control. Otherwise, when set to auto, the operation mode will switch according to outdoor air conditions, regardless of indoor temperature. BRC301B61 26
27 A variety of units can be controlled using only the BRC1D52 or the BRC1E51A (HRV only) Group Control One air conditioner remote control simultaneously controls up to 16 air conditioning and HRV units. Control using 2 remote controls Allows control of air conditioning and HRV units from two locations by connecting two air conditioner remote controls. (group control is possible) Long-distance Remote Control Remote operation control - from a distant control room for example - is possible thanks to wiring of up to 500 m. (2 remote controllers possible) Indoor units Long distance remote control Up to 500m HRV Control using 2 remote controls no2 no1 Group control Up to 500m *1: Count VKM unit as two air conditioner indoor units. For details, see below. System construction (hrv only) System Characteristics Necessary Accessories Independent Operation system BRC1D52 BRC301B61 HRV BRC1D52 BRC301B61 HRV Independent operation of HRV is possible Operation is possible using 2 remote controls Multiple HRV units can be simultaneously controlled in batch. (Up to 8 HRV units can be connected) Air conditioner remote control can be used BRC1D52 or or BRC301B61 Indoor unit HRV Air conditioning interlocked control (VRV, Sky Air) system Standard system Multiple groups interlocked Operation system Group 1 Group 1 BRC1D52 During group control operation, the VKM unit has a capacity equivalent to 2 standard indoor units. Up to 16 standard indoor units can be connected at the same time. Connectable indoor units: VKM Max. no. of VRV Note: The VKM uses 2 remote controller addresses per unit. The number of units that can be group controlled is shown above. Group 1 Group 2 Indoor unit BRC1D52 Indoor unit BRC1D52 Group 2 Group 2 Indoor unit BRC1D52 Indoor unit BRC1D52 Multiple VRV indoor units or HRV units can be connected and controlled in batches, with interlocked operation of HRV and air conditioners by using the air conditioner remote control. The HRV unit can also be operated independently using the remote control for the indoor unit, even if the indoor unit is not in operation Can control interlocked operation of multiple groups of VRV or Sky Air indoor units When one of the multiple groups operates, HRV units are interlocked and operate simultaneously BRC1D52 or BRC1D52 or KRP2A61 HRV HRV BRC301B61 only available for VAM-FA 27
28 Note: Group control is not possible between FXMQ-MF and standard type indoor units. Connect remote controllers to each unit. Not all FXMQ-MF functions are available when using centralised control. Please refer to your local installer for detailed information. The remote control wired to the FXMQ-MF cannot be set as master remote control. Otherwise, when set to auto, the operation mode will switch according to outdoor air conditions, regardless of indoor temperature. Temperature setting and PPD are not possible, even when Intelligent Touch Controller or Intelligent Manager are installed. DCS302C51 Centralised Control Systems By combining the (optional) centralised control equipment listed below, the user can achieve a wide range of comprehensive centralised control systems for air conditioning and ventilation. Centralised remote control - DCS302C51 A maximum of 64 groups (128 indoor units, max. 10 outdoor units) can be controlled A maximum of 128 groups (128 indoor units, max. 10 outdoor units) can be controlled via 2 centralised remote controls in separate locations Group control (up and down buttons are added for group selection) Zone control Malfunction code display Max. wiring length 1,000 m (total : 2,000 m) Combination with unified ON/OFF control, schedule timer and BMS system Airflow volume and direction can be controlled individually for indoor units in each group operation. Ventilation volume and mode can be controlled for Heat Reclaim Ventilation (VKM). Up to 4 operation/stop pairs can be set per day by connecting a schedule timer. DCS301B51 Unified on/off control - DCS301B51 Providing simultaneous and individual control on 16 groups of indoor units A maximum of 16 groups (128 air conditioning indoor and HRV units) can be controlled 2 remote controls in separate locations can be used Centralised control indication Maximum wiring length of 1,000m (total: 2,000m) DST301B51 Schedule timer - DST301B51 Enabling 64 groups to be programmed A maximum of 128 air conditioning indoor and HRV units can be controlled 8 types of weekly schedule A maximum of 48 hours back-up power supply Maximum wiring length of 1,000m (total: 2,000m) 28 Number of HRV units that can be connected per system Centralised remote control Unified on/off control Schedule timer 2 units 8 units 1 unit
29 SYSTEM CONSTRUCTION (HRV only) SYSTEM CHARACTERISTICS NECESSARY ACCESSORIES Unified on/off control - DCS301B51 Batch / Individual Control System Indoor unit BRC1D52 Indoor unit HRV HRV DCS301B51 DST301B51 BRC1D52 One controller can control the on/ off operation of 16 groups of units collectively or individually Up to 8 controllers can be installed in one centralised transmission line (in one system), which enables control of up to 128 groups. (16 groups x 8 = 128 groups) Schedule timer - DST301B51 One schedule timer can control the weekly sche-dule of up to 128 units HRV remote control can set the individual operation of each HRV unit DCS301B51 or DST301B51, BRC1D52 or If necessary: DCS302C51 Air Conditioning Interlocked Centralised Control System Zone Control System Zone 2 Zone 1 BRC1D52 Indoor unit BRC1D52 Indoor unit BRC1D52 HRV HRV BRC1D52 DCS302C51 Control system can be expanded depending on its purposes by combining a variety of centralised control equipment Centralised remote control - DCS302C51 The centralised remote control provides settings and monitoring functions and can control up to 128 VRV and HRV units. A special adapter is required to connect Sky Air to the centralised line. Control is possible in 3 different patterns: individual, batch or zone Multiple groups can be controlled within the same zone Multiple HRV units can be operated independently System without air condi-tioning or HRV remote controls can be constructed Control system can be expanded depending on requirements by combining a variety of centralised control systems DCS302C51, BRC1D52 or If necessary: DSC301B51 or DST301B51 Combination with other types of air conditioners BRC1D52 Adapter Air conditioner No-voltage a-contact signal HRV Connecting line can be extended up to 50m Simultaneous operation of HRVs and air conditioners is possible via BRC1D52/ Use of the HRV remote control enables to change settings or operate HRVs independently Connection adapter (no-voltage-acontact-signal) 29
30
31 ERQ (pair) AND VRV AIR HANDLING APPLICATIONS For small to large commercial spaces Daikin offers a range of R-410A inverter condensing units for use in conjunction with air handling units. In situations where Daikin commercial range ventilation units cannot satisfy the ventilation requirement due to building constraints (large atriums, banquet halls etc), air handling units represent the ideal solution. Air handling units provide large fresh air volumes (> 1,000 m³/h) and high ESPs enabling the use of extensive ductwork runs. For more information on Daikin air handling units refer to the air handling unit catalogue. Benefits of ERQ and VRV air handling applications High efficiency Outside air = 10 C Fresh air supplied at 21 C. The temperature difference with the outdoor air is heated up for free by heat recovery via A/C system Daikin heat pumps are renowned for their high energy efficiency with COPs up to 4.56 in heating 1. The VRV range offers both heat pump and heat recovery units with part load efficiencies as high as Integrating the AHU with a heat recovery system is highly effective since an office system can frequently be in cooling mode while the outdoor air is too cold to be brought inside in an unconditioned state. In this case heat from the offices is merely transferred to heat up the cold incoming fresh air. In the absence of an AHU this free heating the incoming fresh air would not be possible. 1 ERQ100AV1 heat pump 2 REYQ8P8 50% cooling 50% heating load. Conditions: outdoor temperature 11 CDB, indoor temperature 18 CWB, 22 CDB Indoor temperature 22 C, needs cooling because of solar radiation. The excessive heat can be transferred to the AHU High comfort levels Daikin ERQ and VRV units respond rapidly to fluctuations in supply air temperature, resulting in a steady indoor temperature and resultant high comfort levels for the end user. Easy design and installation The system is easy to design and install since no additional water systems such as boilers, tanks and gas connections etc are required. This also reduces the total system cost. Total solution concept Integrating an air handling unit into the total building climate system enables both design and installation procedures to based on a single common technology. This simplifies project follow-up, installation, commissioning and maintenance since only one party is involved. 31
32 which system offers me the best solution? In order to maximise combination potential, Daikin offers pair and multi combination plus several expansion kits and control systems. Control box and expansion valve kits are required for each combination with an air handling unit. Both option kits are designed for indoor and outdoor installation and can be wall mounted. I only need a connection to an air handling unit A solution for your shop, warehouse, showroom or office. ERQ heat pump Inverter controlled units Large capacity range (from 100 to 250 class) Heat pump R-410A Flexible control possibilities Wide range of expansion valve kits available Outdoor unit combined with indoor units Expansion valve kit Air handling unit Control box ERQ System Type Cooling capacity (kw) Heating capacity (kw) Air-cooled ERQ-AV1 ERQ-AW1 I need an air handling unit and heating, and/or cooling Integrate your air handling unit in a Total solution for your shop or office building. VRV heat recovery / heat pump Inverter controlled units Integrates in all VRV heat recovery and heat pump systems up to 54 HP Provides virtually free heating for the air handling unit via recovered heat from indoor units in cooling 1 Control of air temperature via standard Daikin wired remote control Large range of expansion valve kits available Air handling unit Control box Expansion valve kit VRV Outdoor unit 1 In case of connection to a VRV heat recovery outdoor unit 2 For more information on VRV units refer to the VRV catalogue VRV Indoor unit connected to the same system 32 System Type Cooling capacity (kw) Heating capacity (kw) Air-cooled VRV Heat recovery Heat pump Water-cooled VRV Heat recovery Heat pump
33 System overview Pair application: ERQ Expansion valve kit: EKEXV Air handling unit F1, F2 communication Control box: EKEQDCB: Control Z EKEQFCB: Control X,Y DDC controller (field supplied) Control X Multi application: VRV EKEXV-kit Air handling unit Control box: EKEQMCB Control Z Daikin communication wire (F1, F2 communication) Other communication wire Liquid pipe Gas pipe 33
34 Control possibilities In order to maximise installation flexibility, 3 types of control systems are offered: Possibility X (Td/Tr control): Air temperature control via an external DDC controller (field supplied) Room temperature is controlled as a function of the air handling unit suction or discharge air (customer selection). The DDC controller is translating the temperature difference between set point and air suction temperature (or air discharge temperature or room temperature) into a reference voltage (0-10V) which is transferred to the Daikin control box (EKEQFCBA). This reference voltage will be used as the main input value for the compressor frequency control. DDC Daikin control box: EKEQFCB Ts Te AHU TR Td Room Possibility Y (Te/Tc control): By fixed evaporating temperature Daikin control box: EKEQFCB Ts Te AHU TR Td Room A fixed target evaporating temperature of between 3 C and 8 C can be set by the customer. In this case, room temperature is only indirectly controlled. The cooling load is determined from the actual evaporating temperature (i.e. load to the heat exchanger). A Daikin wired remote controller (BRC1D52 or - optional) can be connected for error indication. BRC1D52 Possibility Z (TS/Tr control): ON / OFF Using Daikin wired remote controller (BRC1D52 or - optional) Set point can be fixed via standard Daikin wired remote controller. Remote ON/OFF can be achieved by an optional adapter KRP4A51. No external DDC controller should be connected. The cooling load is determined from the air suction temperature and set point on the Daikin controller. KRP4A51 Daikin control box: EKEQDCB EKEQMCB Ts Te AHU TR Td Room BRC1D52 Ts Td Tr = Air suction temperature = Air discharge temperature = Room temperature Te = Evaporating temperature AHU = Air Handling Unit DDC = Digital Display Controller Option kit Features Possibility x Possibility y EKEQFCB Field supplied DDC controller is required temperature control using air suction or air discharge temperature using fixed evaporating temperature, no set point can be set using remote controller 34 Possibility z ekeqdcb using Daikin wired remote controller BRC1D52 or BRC1E51A ekeqmcb* temperature control using air suction temperature * EKEQMCB (for multi application)
35 35
36 Selection of air handling units Pair application Step 1: Select required capacity of AHU Based on the required capacity of the AHU please select the expansion valve Heat exchanger capacity is defined under following conditions: Saturated suction temperature (SST) = 6 C, Superheat (SH) = 5K Subcool condensor (SC) = 3K Air temperature = 27 CDB/19 CWB Step 1 Allowed heat exchanger volume (dm 3 ) Allowed heat exchanger capacity in coolong (kw) Allowed heat exchanger capacity in heating (kw) EKEXV class Minimum Maximum Minimum Standard Maximum Minimum Standard Maximum Eg: If you need 14kW in cooling, you will require an expansion valve of 125class (EKEXV125). The heat exchanger capacity has priority over the volume of the heat exchanger and is therefore the determining factor for the selection of the expansion valve. More information on the volume can be found in the data book and service manual. Step 2: Select outdoor unit Pair combinations with ERQ outdoor units are possible based on the same principle as standard DX units. The capacity of the AHU unit is indicated by the capacity of the expansion valve and can be connected as indicated in below table. Control box Expansion valve kit Step 2 OUTDOOR UNIT Control z Control x or y Class 63 Class 80 Class 100 Class 125 Class 140 Class 200 Class 250 EKEQDCB EKEQFCB EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 ERQ 1~ 3~ ERQ100AV1 P P P P P P ERQ125AV1 P P P P P P P - - ERQ140AV1 P P - P P P P - - ERQ125AW1 P P P P P P P - - ERQ200AW1 P P - - P P P P P ERQ250AW1 P P P P P P P: Pair, combination depending on AHU coil volume and capacity Eg: Based on above selected expansion valve, the EKEXV125 has a capacity of class 125. Therefore we can choose to connect it in pair with all outdoor units indicated in the table above with P. Step 3: Control box selection 36 Please make your selection of the control box based on your requirements. All the different control possibilities are mentioned on page 34. More information on the selection is available in the service manual.
37 Multi application Step 1: Select required capacity of AHU Based on the required capacity of the AHU please select the expansion valve Step 1 EKEXV class Allowed heat exchanger volume (dm3 ) Allowed heat exchanger capacity in cooling (kw) Allowed heat exchanger capacity in heating (kw) Minimum Maximum Minimum Standard Maximum Minimum Standard Maximum Eg: If the required capacity of the AHU is 6.9kW in cooling, which lies between 6.3 and 7.8, the EKEXV63 can be selected. The heat exchanger capacity has priority over the volume of the heat exchanger and is therefore the determining factor for the selection of the expansion valve. More information on the volume can be found in the data book and service manual. Step 2: Select outdoor unit Multiple AHU can be connected to a VRV system and the connection principle is similar as for ERQ. Connection of the full system can be up till 110% including at least 1 Daikin indoor unit (cassette, duct, ) The capacity index of the AHU needs to be calculated based on the indicated capacity of the selected expansion valve and the actual capacity. The AHU capacity index = capacity class (expansion valve) * ratio (actual capacity AHU / standard capacity expansion valve) Eg: AHU has a capacity requirement of 6.9kW and the selected expansion valvue is the EKEXV63 with a standard capacity of 7.1kW. So the AHU capacity = 63 * (6.9kW / 7.1kW) = 61 class In case that in the system 2 FXSQ50 class are connected, the total sum of capacity would be *50 = 161 class Based on the 161 class a 10 HP is required as outdoor unit. 1 For detailed specifications of VRV outdoor units, refer to the VRV catalogue or databooks Step 3: Control box selection EKEQMCB is the control box which is required to control the communication between the AHU and the VRV system beside the standard communication of the Daikin DX indoor units (cassette, duct, wall ). More information on the selection is available in the service manual. 37
38 ERQ Air handling application (pair) SPECIFICATIONS OUTDOOR UNIT ERQ100AV1 ERQ125AV1 ERQ140AV1 ERQ125AW1 ERQ200AW1 ERQ250AW1 Capacity range HP Cooling capacity nom. kw 11.2 (1) 14.0 (1) 15.5 (1) 14.0 (1) 22.4 (1) 28.0 (1) Heating capacity nom. kw 12.5 (2) 16.0 (2) 18.0 (2) 16.0 (2) 25.0 (2) 31.5 (2) Capacity control cooling min./max. % 24/ Power input cooling nom. kw (1) 5.22 (1) 7.42 (1) heating nom. kw (2) 5.56 (2) 7.70 (2) EER 3.99 (1) 3.42 (1) 3.98 (1) 4.29 (1) 3.77 (1) COP 4.56 (2) 4.15 (2) 3.94 (2) 4.00 (2) 4.50 (2) 4.09 (2) Casing colour Daikin White Daikin White material Painted galvanized steel plate Painted galvanized steel plate Dimensions unit heightxwidthxdepth mm 1,345x900x320 1,680x635x765 1,680x930x765 Weight unit kg rows quantity 2 54 fin pitch mm 2 2 Heat exchanger face area m² stages quantity 60 2 fin type Non-symmetric waffle louvre Non-symmetric waffle louvre type Propeller fan Propeller fan Fan cooling nom. m³/min air flow rate heating nom. m³/min Fan motor model Brushless DC motor Brushless DC motor drive Direct drive Sound power level cooling nom. dba Sound pressure cooling nom. dba level heating nom. dba Compressor model JT100G-VDL Inverter type Hermetically sealed scroll compressor Hermetically sealed scroll compressor Operation range cooling min.~ max. CDB -5~ 46-5~ 43 heating min.~max. CWB -20~ ~15 Enterning air cooling min.~ max. CDB -14CWB~25CWB 35 CDB temperature on AHU heating min.~max. CWB heat exchanger 10CWB~27CWB 10CWB~27CWB type R-410A R-410A Refrigerant charge kg control Expansion valve (electronic type) Electronic expansion valve Refrigerant oil type Daphne FVC68D Synthetic (ether) oil charged volume l Piping connections liquid type/od mm Flare connection/9.52 Braze connection/9.52 gas type/od mm Flare connection/15.9 Braze connection/19.1 Braze connection/15.9 Braze connection/19.1 Braze connection/22.2 drain quantity/od mm 3/26x3 - heat insulation Both liquid and gas pipes Both liquid and gas pipes Safety devices item 01/02/03/04 High pressure switch/fan motor thermal protection/inverter overload protector/pc board fuse High pressure switch/fan motor driver overload protector/overcurrent relay/ Inverter overload protector/pc board fuse Power supply phase/frequency/voltage Hz/V 1N~/50/ N~/50/400 (1) Cooling: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; equivalent piping length: 7.5m (horizontal); level difference: 0m (2) Heating: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (3) Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. (4) Sound values are measured in a semi-anechoic room. EKEXV Expansion valve kit INDOOR UNIT EKEXV50 EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 Casing Colour Ivory white Material Metal Dimensions Unit HeightxWidthxDepth mm 401x215x78 Weight Unit kg 2.9 Operation range Cooling Min.~ Max. CDB -5.0~ 46.0 Refrigerant Type R-410A Liquid Type/OD mm Braze connection/6.35 Braze connection/9.52 Gas Type/OD mm Braze connection/6.35 Braze connection/9.52 Piping connections Piping length System Chargeless m 0 Heat insulation Both inlet and outlet Power supply Phase/Frequency/Voltage Hz/V /-/- (1) The sound pressure value is the maximum value measured at 10cm from the motor. (2) Minimum and maximum piping length refer to the piping between the expansion valve kit (EKEXV) and the air handling unit (3) Equivalent piping length: refer to the capacity connection ratio of the outdoor unit; depends on outdoor unit (4) The temperature of the air entering the coil in heating mode can be reduced to -5 CDB. Contact your local dealer for more information. 38
39 EKEQ Control box Indoor unit EKEQDCB EKEQFCB EKEQMCB Application Pair Multi Outdoor unit ERQ VRV Casing Colour White grey Material Resin Dimensions Unit HeightxWidthxDepth mm 132x400x200 Weight Unit kg Operation range Cooling Min.~ Max. CDB -10~ 40 Refrigerant Type - Power supply Phase/Frequency/Voltage Hz/V 1~/50/230 accessories ERQ ERQ AV1 ERQ140AV1 ERQ125AW1 ERQ AW1 Central drain pan KWC26B160 KWC26B280 Central drain plug KKPJ5F180 KKPJ5F180 - Cool/heat selector Fixing box Notes (1) Filter chamber has a suction-type flange. (Main unit does not). Some options may not be usable due to the equipment installations conditions. Please conrfirm prior to ordering. Some options may not be used in combination. Operating sound may increase somewhat depending on the options used. KRC19-26A6 KJB111A EKEQ EKEQFCB EKEQDCB EKEQMCB Wired remote control BRC1E52A / BRC1D52 BRC1E52A / BRC1D52 1 BRC1E52A / BRC1D52 1 Wiring adapter for electrical appendices (control and monitoring F1 F2) KRP2A61 - KRP4A51 Remote sensor - - KRCS01-1 Notes (1) Cool/heat selector required for operation (2) Do not connect the system to DIII-net devices (Intelligent controller, Intelligent Manager, LonWorks interface, BACnet interface ). Caution for options - Do not connect the system to DIII-net devices (Intelligent Controller, Intelligent Manager, LonWorks interface, BACnet interface ). This could result in malfunction or breakdown of the total system. - Only use the ERQ, EKEQ, EKEXV in combination with an air handling unit. Do not connect this system to other indoor units. 39
40 Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. FSC ECPEN The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium BE RPR Oostende ECPEN CD 05/12 Copyright Daikin The present publication supersedes ECPEN Printed on non-chlorinated paper. Prepared by La Movida, Belgium Resp. Ed.: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende
Daikin Airconditioning UK Ltd HRV. Heat Reclaim Ventilation VAM-FA VKM-GM VKM-G
Daikin Airconditioning UK Ltd Heat Reclaim Ventilation VAM-FA VKM-GM VKM-G contents p. 3 Table of Contents INTRODUCTION GENERAL FEATURES Energy Efficiency Design Flexibility Clean Air VKM FEATURES Energy
york air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
FTQ. Daikin Inverter Ducted Heat Pump
FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative
OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)
OPERATION MANUAL (Ceiling mounted duct type) VAM50FB VAM500FB VAM650FB VAM800FB VAM000FB VAM500FB VAM000FB 8 7 6 9 5 7 5 0 6 8 6 9 0 5 5 7 7 6 7 A A B B 5 6 5 6 7 VAM50F VAM800F VAM500F VAM500F VAM000F
FTXS. Wall Mount Heat Pump or Cooling Only
FTXS Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FTXS SkyAir systems feature streamlined, wall mounted indoor units paired with quietly compact outdoor units. Available in both
technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air
technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t
Air conditioners Heating & Cooling
Air conditioners Heating & Cooling Replacement VRV Cost effective upgrade for R-22 s High efficiency Possibility to increase capacity Limited and planned downtime Limited and phased investment cost www.daikin.eu
FULL DC INVERTER SYSTEMS
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation
Air Conditioners Technical Data
Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................
New Deluxe Wall Mounted Heat Pump Series EXTERIOS
New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History
AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -
AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness
Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75
Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER
Innovent LASER Packaged Fresh Air Conditioning Units
LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent
LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy
LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
FBQ. DC Duct Heat Pump or Cooling Only
FBQ DC Duct Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FBQ DC Duct systems offer a powerful solution, compact in design and easily concealed in a ceiling. With both cooling only and heat
Air Conditioners Technical Data
Air Conditioners Technical Data C e i l i n g s u s p e n d e d u n i t E E D E N 2-0 0 FHQ-B8 Indoor Unit Ceiling suspended unit FHQ-B8 TABLE OF CONTENTS FHQ-B8 Features.............................................................
CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability
PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories
Lesson 36 Selection Of Air Conditioning Systems
Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section
CRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
FHQ. Ceiling Suspended Heat Pump or Cooling Only
FHQ Ceiling Suspended Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FHQ ceiling suspended SkyAir systems are ideal for applications without false ceilings. Installed from the structure, this
VRV III Inverter system, R-410A Table of contents
Ceník 2009 Inverter system, R-410A Table of contents Indoor units Round flow cassette FXFQ...3 4-way blow ceiling suspended unit + BEV box FXUQ... 4 4-way blow ceiling mounted cassette (600x600) FXZQ...
FCQ. Roundflow Cassette Heat Pump or Cooling Only
FCQ Roundflow Cassette Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FCQ roundflow cassette SkyAir systems are ideal for open plan applications where variances in temperature and airflow
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
DUCTED AIR CONDITIONING SOLUTIONS
DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE
Bring the fresh in. Dedicated Outside Air Systems
Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health
SWIMMING POOL AIR-HANDLING UNITS KU-DB Series
SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =
Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools
Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL
Unico Inverter. Unique and efficient.
Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed
The natural ombination
The natural ombination DAIKIN ALTHERMA HYBRID HEAT PUMP 2 A new pportunity in residential heating! There is a growing demand from home owners to replace heating systems, especially replacing of gas boilers,
For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System
For Residential & Light Commercial Applications 4 Ton 8 Zone Multi Split Heat Pump System EXPERTISE AND INNOVATION The Super Multi PLUS Split System is the ultimate, flexible solution for individual zone
HVAC Simplified Approach Option
HVAC Simplified Approach Option Part I Project Address: City: HVAC System Designer of Record: Date: Zip: Qualification The building is 2 stories or less in height and has a gross floor area is less than
Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features
RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,
hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
Daikin Altherma hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient
Gree Solar Hybrid Hi Wall Inverter Air Conditioner
Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar
SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT
Energy Efficiency HOSPITALITY. www.energia.ie
Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real
EDUS 391004 - M_a. General Information RXYQ-PB REYQ-P(B)
EDUS 391004 - M_a General Information RXYQ-PB REYQ-P(B) AMERICAS General Information... (This booklet) Indoor Units Ceiling-Mounted Cassette Type (Round Flow)... 4-Way Ceiling Mounted Cassette Type (2
Air conditioners, Heating & Cooling. Biddle air curtain for connection to daikin heat pumps. www.daikin.eu
Air conditioners, Heating & Cooling Biddle air curtain for connection to daikin heat pumps www.daikin.eu Daikin Europe N.V. DAIKIN, THE COMPANY Daikin has a worldwide reputation based on almost 85 years
UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)
UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery
LG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
URURU SARARA: THE AIR CONDITIONER THAT COOLS, HEATS, HUMIDIFIES, DEHUMIDIFIES, PURIFIES AND VENTILATES;
MODERN AIR CONDITIONERS NOT ONLY COOL BUT HEAT THE AIR AS WELL. YOU CAN ADJUST THE TEMPERATURE IN YOUR HOME ALL YEAR ROUND WITH ONLY ONE SYSTEM. THERE IS MORE THAN JUST A PLEASANT TEMPERATURE NEEDED TO
Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.
Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities. More Freedom to Administrators Connectable up to 128 Indoor Unit Groups (256 indoor
CE6500 Energy Recovery Ventilator
ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge
Operation and Installation Manual. Max Series
Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat
Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE
Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
Inverter Air Conditioning for Light Commercial Use
Inverter Air Conditioning for Light Commercial Use 02 Cost Saving Comfort An efficient use of time 03 SDISuper Digital Inverter Very efficient energy consumption Keeps down operating costs Heater operation
R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
air conditioners for your home, shops, restaurants, offices, small hotels w w w. d a i k i n. e u M U L T I M O D E L A P P L I C A T I O N S
air conditioners for your home, shops, restaurants, offices, small hotels M U L T I M O D E L A P P L I C A T I O N S ABOUT DAIKIN Daikin has a worldwide reputation based on over 80 years experience in
HP switch LP switch Discharge thermo Comp. Surface thermo
1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer
emura Form. redefined.
emura Form. function. redefined. IT S ALL ABOUT DESIGN if award Daikin Europe N.V. is proud to announce that Daikin Emura has been awarded an if Product Design Award for 2010. For 56 years, the if product
All the best brands all under one roof
All the best brands all under one roof Year round comfort and energy efficiency The air conditioner you choose today is going to be with you for a long time, so it s important to choose wisely. The best
PLUG and PLAY VRV Connection
PLUG and PLAY VRV Connection All seasons Perfect c mfort Heating Air Conditioning Applied Systems Refrigeration Pricelist 2010 Air Handling Units for > VRV Indoor units and Air Handling Units on single
Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...
Solar air collectors for industry and larger halls N S Ø Efficient dehumidification and air heating for free... This booklet contains information about SolarVenti Industrial air solar system. The system
Hot Water. Heat pump water heaters. Residential and Commercial R410a
Hot Water Heat pump water heaters Residential and Commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating
Contents. Part 1 General Information... 1. Part 2 Outdoor Units... 9. Part 3 Installation... 50. Part 4 Troubleshooting 73
MCAC-VTSM-2013-03 R410a Full DC Inverter Mini VRF Contents Part 1 General Information... 1 Part 2 Outdoor Units... 9 Part 3 Installation... 50 Part 4 Troubleshooting 73 Part 5 Control System... 100 Manufacture
Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort
Heat Pump Product Brochure 2015/2016 Premier Series Hi-Wall Split Systems Everyday Comfort Everyday Innovation We design with you in mind. You ll find that Haier Heat Pump units are quiet, efficient and
USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA
USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
NETWORK SOLUTIONS. www.daikin.eu
NETWORK SOLUTIONS www.daikin.eu A l l o w s d e ta i l e d a n d e a s y m o n i t o r i n g a n d o p e r at i o n o f V R V s y s t e m s ( m a x i m u m 2 x 6 4 g r o u p s / i n d o o r u n i t s )
Pioneer in sustainability
Pioneer in sustainability Over 100 years ago Carrier helped pioneer a new industry, and in the last two decades we have pioneered environmentally sensitive products with a reduced impact on the environment.
HEATER, AIR CONDITIONING AND VENTILATION
55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT
MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS
MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS POER, FLEXIBILITY, RESIDENTIAL Carrier presents the new line of multi-split systems A complete and flexible range designed to meet every residential and light
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
HVAC Systems: Overview
HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct
Daikin Altherma. hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Why choose Daikin? As an industry leader, Daikin combines broad experience, technical innovation and responsive customer service to help you meet
How To Design A Building In New Delhi
ENERGY EFFICIENT HVAC DESIGN FOR COMPOSITE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce energy consumption
Refrigeration Compressed Air Dryer Buran Ultrapulse
Refrigeration Compressed Air Dryer Buran Ultrapulse There is more to compressed air than just compressing air Compressed air is an indispensable source of operating and processing power in all areas of
Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
Appendix - Controllers 179
Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
2015 HVAC Excellence Educator Conference Variable Refrigerant Flow & Variable Refrigerant Temperature
2015 HVAC Excellence Educator Conference Variable Refrigerant Flow & Variable Refrigerant Temperature Slide 1 Residential Market Push for more efficiency Green Building Initiative R-22 & High Efficiency
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A
More than Air Conditioning Catalogue 2004/2005 Air Conditioning Program R 407C R 410A MITSUBISHI ELECTRIC Air Conditioning Systems As one of the world s leading technology companies, MITSUBISHI ELECTRIC
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries
ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE
ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce
SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC
SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED
Horizontal ventilation units
THE ART OF AIR INNOVATION SINCE 1983 FOR HOMES AND BUSINESSES Horizontal ventilation units Healthy indoor air increases your well-being Today people spend much of their life indoors. It is therefore important
SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump
SiBE12-625 D-Series / E-Series [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SUPER MULTI NX D-Series / E-Series Cooling Only Indoor Unit FTKS20D3VMW FTKS20CAVMB FDKS25CAVMB
Air Conditioners. Technical Data. Wall Mounted Unit. www.daikin.eu RX-JV/GV
Air Conditioners Technical Data Wall Mounted Unit www.daikin.eu RX-JV/GV Air Conditioners Technical Data Wall Mounted Unit www.daikin.eu RX-JV/GV TABLE OF CONTENTS RX-JV/GV 1 Features.............................................................
1932 Lexington Houston, Texas 77098-4220 (713) 524-4877. Recommendations for installation of cooling systems
1932 Lexington Houston, Texas 77098-4220 (713) 524-4877 The purpose for this information is to provide a better understanding of the HVAC equipment, components, designs, and installations, of HVAC system
Delivering exceptional performance and Ecovalue. Ecocent
1 Delivering exceptional performance and Ecovalue. Ecocent 2 The Ecocent Hot Water System As the cost of providing heating and hot water continues to increase, homes and businesses are seeking out more
The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair
The Concept A Europe-wide research and development programme identified the need for a high performance cassette fan convector, powered by low pressure hot water and compatible with universal suspended
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
Versati Air to Water Heat Pump
Versati Air to Water Heat Pump VERSATI DC Inverter Multifunctional Air To Water Heat Pump Nowadays, people are increasingly focusing on heating costs as well as environmental issues. Traditional heating
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ ISO 9001 ISO 14001 Certified number : 01 100 89394 Certified number : 01 104 9245101 Fujitsu General (Thailand) Co.,
PRODUCT CATALOG. Indoor Units
PRODUCT CATALOG Indoor Units Life s Good! From installation to maintenance, LG runs more than 60 global air conditioning academies, each provides training for air conditioning professionals. What is LG?
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS
DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS AN EXCELLENT CHOICE IN COOLING, COMFORT AND CONVENIENCE Why choose a Mini-Split system? Installing
1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
elcome to the era of the SEER seasonal efficiency Product range
elcome to the era of the SEER seasonal efficiency Product range Daikin leads the way: Seasonal series Daikin again leads the industry with their full light commercial range optimised for seasonal efficiency,
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
ASTACEA4 Inspect complex/central air conditioning systems
Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air
Failure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
DESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LECA AS G09LECA AS G12LECA AS G14LECA OUTDOOR AO G07LEC AO G09LEC AO G12LEC AO G14LEC 1. INDOOR UNIT : AS G07LECA AS G09LECA AS
Energy Efficiency. Bars & RestauRants. www.energia.ie
Energy Efficiency Bars & RestauRants www.energia.ie 2 Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could