PRESERVATION AND PACKING BASE INSTRUCTIONS GENERAL DOCUMENT. ERECTION INSTRUCTION Project handbook - section 7.2 preservation and packing instruction
|
|
|
- Willa Jacobs
- 9 years ago
- Views:
Transcription
1 Project handbook - section PRESERVATION AND PACKING BASE INSTRUCTIONS Buch: Generally revised Buch: Packing of Francis runner 112 revised HWK/Buch: Generally revised (Codes/Marking/Storage) HWK: General Changes in Chapters 1, 3, 1 and HWK: Documentname; chapter 1; item 10 in Chapter 4 added, hazardous replaced by dangerous Corporate design adjustments - Update of Standards VN156-1 and VN15-1 Page 1 of 82
2 Project handbook - section 2 Table of Content: Objective 6 2 Reference Documents 3 General conditions for preservation and packing 8 31 Climate conditions 8 32 Abnormal dimensions/heavy lifts/transport drawings Days advice 9 34 External packing inspection (for direct deliveries) 9 35 Guarantee 9 4 Special conditions for preservation and packing 10 5 PRESERVATION REQUIREMENTS for shipping Corrosion protection Use of desiccants VCI Method (Volatile Corrosion Inhibitor) General 1 6 Preservation matrix 1 Preservation codes 18 8 Goods classes (GK) 19 9 Packing matrix Storage code Packing categories Packing category VK 0: no packing, Components are not packed 23 Page 2 of 82
3 Project handbook - section 2 GENERAL DOCUMENT Packing category VK 1: Shrink-wrap in PE foil Instructions for shrink-wrapping Packing category VK 2: Cardboard box Packing category VK 3: Wooden supports Packing category VK 4: Pallets Packing category VK 5: Standard drum Packing category VK 5a: Seaworthy drum packing Packing category VK 6: Sheathing Lamella packing Wooden laths Packing category VK : Standard crate (without lining) Crate bottom Side walls, face walls and cover Stack pressure Packing category VK 8: Seaworthy crate (with lining) Packing category VK 9: Seaworthy crate (with lining and shrink wrap) Crate and cover design Goods After processing Packed goods Goods that may vibrate Packing category VK 10: Shipper's own container Fastening on the container floor Preservation and packing of pipes for transport to site Preservation of Pipes Pipes of stainless steel: Pipes of carbon steel: Packing of pipes Packing standard and construction of packings Packing list 41 Page 3 of 82
4 Project handbook - section 2 GENERAL DOCUMENT Load assumption Loads due to crushing in stacks Horizontal Loads Vertical Loads Stresses through falling and vibrations Transverse forces during crane handling Tilting stresses Centre of gravity indication Size and weight of package Sizes and weight limitations Construction of packings Standard packing Particular packing WOODEN CRATES (TYPES AND CONSTRUCTION ELEMENTS) Wooden cases/plywood cases (construction elements) SKID/SUB-Skid Arrangement for cases and crates Wooden saddles/skids (types and construction elements) Packing and shipping procedure Packing materials Quality of wood ISPM 15 GUIDELINES FOR REGULATING WOOD PACKAGING MATERIAL Foils Padding and filler materials Bolts and screws Nails 2 1 Dispatch and marking instruction for handling of the goods 3 11 General 3 12 Labeling 4 Page 4 of 82
5 Project handbook - section 2 GENERAL DOCUMENT Project related with client name etc as per the contractual stipulations: Project related out of the DIA-AL System of Voith Hydro for internal purposes Shipping Instruction: 6 13 Cautionary Symbols 6 14 Marking of Packages; Directive for Export Packaging Packing Instruction for special parts Attached standards 82 Page 5 of 82
6 Project handbook - section Objective This Instruction gives an overview of the measures to be taken for the shipping preservation, packing and site-storage of Turbine, Generator and Governor and BOP components in order to prevent them from damage during transshipment and storage It considers the conservation for seaworthy packing and also for short term storage at site For showing the importance of this subject This document covers the general aspects of the contract and will be supplemented by modules for the specific parts Note: For preservation and packing, a standard period of 6 month is assumed for the duration of site storage until the parts are assembled or installed If the duration for site storage exceeds 6 months, or the duration for transport and site-storage exceeds 12 months, special precautions have to be taken For quick reference see the following items which are the backbone of this document: Preservation matrix Item 6 Preservation codes (K0 - K6) Item Goods classes (GK1 - GK9) Item 8 Packing matrix Item 9 Packing categories (VK0 - VK10) Item 11 Page 6 of 82
7 Project handbook - section Reference Documents VN - Standard Preservation and Storage VN - Standard 15-1 General Packing Standard VSN - Standard Dispatch Preservation of Machine Parts ISPM 15 GUIDELINES FOR REGULATING WOOD PACKAGING MATERIAL HPE packaging guidelines Page of 82
8 Project handbook - section General conditions for preservation and packing The packing has to fulfill the requirement stated in item 13 of this document and shall be suitable for various handling operations, long distance ocean and inland transportation, as well as it shall ensure the protections of goods therein contained against weather elements or other, not only during the time required for transport and transshipment, but also for at site storage at climate condition of the plant site for a total time not less than 12 months For any different typology of packing not covered by this specification, the contractor shall propose at time of the quotation submittal on the basis of proper manufacturing experiences, other packing solutions that in his opinion are more economic and more suitable for specific applications and needs Any alternative proposals submitted after the placement of order will not be considered The regulations of the respective countries for importation of wooden packing material according to IPPC Standard No 15 (valid at time of importation) are to be observed (see item 16 of this document) 31 Climate conditions Kindly refer to project specific document or the Purchase Order, in which below information is given Climate conditions on plant site are as follows: Temperature: o Extreme lowest temperature o Extreme highest temperature Humidity: o Maximum relative humidity o Minimum relative humidity Rainfall: o Maximum in one hour o Average per year to be informed: to be informed: to be informed: to be informed: to be informed: to be informed: Snowfall to be informed: Page 8 of 82
9 Project handbook - section 2 GENERAL DOCUMENT Sea Breeze to be informed: Miscellaneous to be informed: 32 Abnormal dimensions/heavy lifts/transport drawings In the event that abnormal dimensions should be included in scope of supplies, supplier is obliged to respect the relative regulations for such transportation and get necessary permits as per the agreed price basis in due time prior to dispatch of the goods Supplier should submit to Voith Hydro, as soon as possible, but at least 3 months after receipt of the order or at least 60 days ahead of the ex works date, three dimensions transport drawings (3-fold), for all equipment exceeding the following dimensions and / or weight (or a part) in packed condition (in case of deliveries less than 60 days, the notification should be made immediately after placement of the order) Note: National and international standard for package sizes and weight limitations for land transport: Gross weight: 20 tons and / or Dimensions: 1180 x 230 x 230cm (length x width x height) For more details see also paragraph 12 of this document Days advice The attached 28 days advice form has to be completed according to the specification and should be submitted to Voith Hydro at least 45 days prior to the delivery date This information is required in order to be able to book the necessary vessel stowage space 34 External packing inspection (for direct deliveries) 1 Voith Hydro has the right to inspect packing at the contractor's at any time 2 If repeated inspections are necessary due to the contractor's fault, the contractor must bear the resulting costs (eg personnel, travel, material costs) 3 Inspection of packing does not release the contractor from its contractual obligations 35 Guarantee The contractor guarantees the contractual design of the packing according to the state of the art, in particular the best quality and suitability of the packing material, as well as Page 9 of 82
10 Project handbook - section 2 GENERAL DOCUMENT suitability of the packing, taking into account the goods to be packed and the actual stresses, for the warranty period set forth in the relevant contracts The contractor is responsible for all goods losses and/or damages deriving from defective packing (March 2008, VN 15-1) 4 Special conditions for preservation and packing For preservation and packing of equipment for hydro power units, the requirements and procedures are structured in this document as follows: Preservation matrix Paragraph 6 Preservation code (K0 K6) Paragraph Goods classes (GK1 GK9) Paragraph 8 Packing matrix Paragraph 9 Packing categories (VK0VK10) Paragraph 11 Packing standard and construction of packings Paragraph 13 Dispatch and marking instruction for handling of the goods Paragraph 1 Packing instruction for special parts Paragraph 18 Attached Standards Paragraph 19 If in case of direct deliveries the contractor cannot unambiguously determine the goods class, Voith Hydro must be contacted 1 The contractor is responsible for selecting the packing category, corrosion protection according to this document and the materials to be used If wooden supports, pallets, crates, part packing, etc are made the packing must be reasonably designed for the weight and properties of the goods as described herein 2 This packing standard must be understood as minimum requirements If additional measures are required in the contractor's experience to protect the goods, they must be taken in agreement with Voith Hydro 3 The contractor is obliged to use economical and space-saving packing Options of copacking must considered and utilized after discussion with Voith Hydro 4 Packing must generally be designed in such a manner that the packed goods and the packing can be transported and stored without damage Furthermore, the packing must withstand several transshipments during transport Page 10 of 82
11 Project handbook - section 2 GENERAL DOCUMENT Small parts (bolts, nuts, washers, etc) must be packed in plastic bags 6 The climatic conditions of sea transport (eg contact to salt water, condensation water, salty air, temperature variations, etc) must be taken into account especially with respect to corrosion protection and selection of the packing category The designation and description of the content of packing must completely and fully correspond with the packing lists A copy of this packing list must be attached waterproofed to the packing (in a metal or plastic frame) Special care must be taken that there is no indication of the supplier (neutral paper or packing list handed over by Voith Hydro) See also paragraph 121 of this document 8 If the packing is specified in other documents (eg project guideline, drawing, etc) for specific orders or products, these specifications must be met 9 Packing must take special care to pack assemblies together 10 Dangerous goods have always to be packed separately, never together with nondangerous goods; shipping documents for dangerous goods have to be as well separately Page 11 of 82
12 Project handbook - section PRESERVATION REQUIREMENTS for shipping 51 Corrosion protection Due to the long transport and storage period, all sensitive equipment - in addition to corrosion protection applied to the goods by the manufacturer - must be protected from corrosion For the preservation for packing and shipping follow the instruction given in this document The processing requirements for the relevant corrosion protection agent must be met under all circumstances In case that no special instructions are applicable, the following has to be adhered for packing of goods: Materials, which are sensitive for corrosion due to their design and properties, have to be shrink-wrapped into film sheeting The minimum thickness of the film is 02 mm When selecting the film (polyethylene or aluminum compound sheeting), its barrier properties against water together with the transport and storage time have to be taken into consideration (see also item 1522 for more detailed information) (According VN15-1 paragraph 521, attached to this document at the end for reference) Note: For transport and storage time of 12 month, add a quantity of moisture absorbent (silica gel) to the packed item which is sufficient to keep the relative humidity within the barrier sheeting below the value of 50 % for the entire duration of transport and storage (calculated according to DIN HPE Standard), see also item 52 and 53 below The use of hygroscopic filler and cushioning means (eg wood shavings, hay, straw, paper) for filling empty gaps and cushioning purposes is not permitted The required preservation conditions for the various turbine - generator - governor and BOP equipment are given below and have to be applied to the individual components This information is based on the VSN Preservation and Storage, which is attached to this document at the end for reference Page 12 of 82
13 Project handbook - section 2 52 Use of desiccants Page 13 of 82
14 Project handbook - section Page 14 of 82
15 Project handbook - section Page 15 of 82
16 Project handbook - section 2 53 VCI Method (Volatile Corrosion Inhibitor) Page 16 of 82
17 Project handbook - section 2 GENERAL DOCUMENT (Regarding VCI - Volatile Corrosion Inhibitors - see also item 1522 Foils) 54 General All parts of rustproof materials (eg rustproof steel, aluminum, bronze, plastic, etc) are not preserved For all preserved parts, a water-tight sealing layer must be used as a separating layer to a wooden support Paper or cardboard must not be used due to potentially occurring moisture 521 Application of Anticorit DFW 330 or Hölterol Spray on Anticorit DFW 330 or Hölterol at room temperature in such a manner that a covering layer is formed on the shell surface and in the boreholes The drying time of at least 6 hours at room temperature must be adhered to under all circumstances 522 Application of Tectyl 506 Spray on Tectyl 506 at room temperature in such a manner that a covering layer is formed on the shell surface The drying time of at least 24 hours at room temperature must be adhered to under all circumstances 6 Preservation matrix Transport types Truck Rail Sea Container Air Goods class (GK) Preservation 3) Storage 4) Corrosion-resistant 1) materials K 0 K 0 K 0 K 0 K 0 S3, S4 Materials sensitive 2) to corrosion K 1, K 2 K 1, K 2 K 1, K 2, K3 K 1, K 2, K3 K 1, K 2 S3 Shafts, trunnions K 6 K 6 K 6 K 6 K 6 S2, S3 Electrical and electronic devices K 4, K 5 K 4, K 5 K 4, K 5 K 4, K 5 K 4, K 5 S1, S2 1) Including components of 188 material 2) Including Turbine components of 134 material 3) In Table 1 paragraph, the preservation codes are described in detail Page 1 of 82
18 Project handbook - section 2 4) See paragraph 10 Storage Code for storage requirements Preservation codes Preserv Code Table 1 GENERAL DOCUMENT K 0 K 1 K 2 K 3 K 4 K 5 K 6 no preservation VCI method (Volatile Corrosion Inhibitors) Preservation in corrosion-retardant atmosphere (eg VCI method) Recommended for small parts, mass-produced goods, etc for example thin-layer preservation Preservation for all bare and unpainted exterior surfaces: Apply Anticorit DFW330 or Hölterol Cover and/or wrap the parts so preserved in oil paper thick-layer preservation Preservation for all bare and unpainted exterior surfaces: Apply Tectyl 506 or Hölterol Bores and threaded holes are preserved using Anticorit DFW330 or Hölterol If the components are not additionally packed, the bores and threaded holes must be closed, eg by means of a plastic plug (including parts lined with rustproof steel) foil bag open on bottom Electrical and electronic equipment as delivered in foil bag that is open on the bottom closed foil bag Electrical and electronic equipment as delivered in foil bag that is welded shut Add a sufficient amount of desiccant (Silica gel or diatomite) Preservation for shafts / trunnions Preservation for all bare and unpainted exterior surfaces of the shaft / trunnion: Apply Tectyl 506 DFW330 or Hölterol Wrap roll width with corrosion-protecting paper eg Branorost without wrinkles Wrap roll width with fabric paper, sheet overlapping at least 30 cm Face-side projection (approx 30 cm) on the roll, face to be pressed on and fixed Bores and threaded holes are preserved using Anticorit DFW330 or Hölterol If the components are not additionally packed, the bores and threaded holes Page 18 of 82
19 Project handbook - section 2 GENERAL DOCUMENT must be closed, eg by means of a plastic plug (including parts lined with rustproof steel) 8 Goods classes (GK) As the materials to be packed are of different physical and chemical sensitivities, they are grouped in the following goods classes dependent on their properties If the contractor cannot unambiguously determine the goods class, Voith must be contacted Goods class GK 1 Shock and corrosion-resistant parts, eg piping and support structures, steel structures, sections, formed pipes, scaffolding, etc Goods class GK 2 Cable on cable drums Goods class GK 3 Shock and corrosion-resistant, heavy, bulky materials Framework parts, walkways, containers with exterior elements, machined piping, support structures, parts with cooling ribs, robust machines, thin-walled sheet-metal parts (pans, wire pans, vats), equipment, etc which are largely insensitive to physical and chemical influences (UV radiation, salt water, etc), fluids and bulk goods in barrels or other containers, etc Goods class GK 4 Corrosion-resistant materials requiring physical protection or cannot be classified in goods class GK 3 due to their size (small parts) Non-hygroscopic insulating material, plastic, coated steel parts, etc Goods class GK 5 Corrosion-sensitive materials that require physical protection Machine elements (wicket gates, couplings, axles, shafts, etc), fastening elements (screws, wedges, springs, bolts, etc), Other structural parts (flanges, brackets, etc), simplest and insensitive parts of general mechanics, refractory materials, etc Goods class GK 6 Materials that require physical and chemical protection Shafts, trunnions, parts with ultra fine machining, parts of general mechanics such as gearboxes, machines, bearings, shaft seals, fittings, etc Page 19 of 82
20 Project handbook - section 2 GENERAL DOCUMENT Goods class GK Materials that require physical and chemical protection Fine mechanical, electrical, electro-mechanical and electronic materials (control cabinets, mcb, motors, etc), etc Goods class GK 8 Materials which are sensitive to corrosion and/or extraordinarily sensitive to shock/vibration: Electronic and fine mechanical measuring devices, computers, etc Goods class GK 9 Dangerous goods Paints, adhesives, chemicals, acids, solvents, propellants, etc Attention must always be paid to legal requirements! (March 2008 VN 15-1 Page 4) Page 20 of 82
21 Project handbook - section Packing matrix If several means of transportation are used for goods shipping, packing must be in accordance with the highest packing category/transport class 1) Like transport class 3 (sea freight) but transported in shipping container A shipping container is not considered to be packing but a means of conveyance and/or transport container 2) If required, air-conditioning must be indicated additionally Page 21 of 82
22 Project handbook - section 2 10 Storage code GENERAL DOCUMENT The required storage conditions for the various turbine, generator, governor and BOP components are specified in the table below and have to be applied to the individual components Storage Code S 0 Location Description S 1 Heated /Refrigerated 5 C/41 F to 25 C/ F HC 1* Indoor S 2 Heated above 5 C/41 F frost free HC 2* S 3 S 4 S 5 Outdoor Refrigerated Not heated Covered, ventilated, off ground Uncovered on blocks, off ground * HC 1= Humidity controlled (less than 50%) * HC 2= Humidity less than 0% 3 C/3 F to 10 C/50 F 11 Packing categories The type of packing for the different components is defined in VN 15-1 paragraph 5 and is given below for reference Packing category description Packing category VK 0: Packing category VK 1: Unpacked Shrink-wrap in PE foil Packing category VK 2: Cardboard box Packing category VK 3: Wooden supports Packing category VK 4: Pallets Packing category VK 5: Standard drum Packing category VK 5a: Seaworthy drum packing Packing category VK 6: Sheathing Packing category VK : Standard crate (without lining) Packing category VK 8: Seaworthy crate (with lining) Packing category VK 9: Seaworthy crate (with lining and sealing in foil) Packing category VK 10: Shippers own container Page 22 of 82
23 Project handbook - section Packing category VK 0: no packing, Components are not packed 112 Packing category VK 1: Shrink-wrap in PE foil Fig 1 Example: Shrink-wrap in PE foil Note1: The special requirements for shrinkwrapping are described in paragraph 1021 according to VN 15-1, which is attached to this document at the end for detailed information Note2: Do not make an entire wrapping, as shown as an example in the picture below, in order to avoid the accumulation of water and dust PE-foil PE-foil Wrong Right For large packings, the shrink-wrapping must be made by welding the segments as shown below: Wrapping splice (welding) Example: Welded segments of the wrapping Upper and lower part of Execution the wrapping OU: Page 23 of 82 Side part of the wrapping (contour) external and internal diameter
24 Project handbook - section Instructions for shrink-wrapping A special PE shrink-wrap foil must be used so that machine parts can be shrink-wrapped The foil is placed on the object to be packed and stapled to the supporting wood or pallet, if any Then the shrink-wrap foil is evenly heated by means of a gas flame or electrical heater Care must be taken that the heater is not held in one place for too long, but traced over the foil in coating movements (see photos below) Heating softens the plastic which clings to the object to be shrink-wrapped After cooling, the foil tightly clings to the packed good and has significantly more strength than in the original condition If holes occur during the shrinking process, they must be closed by means of adhesive tape Tools for shrink-wrapping Page 24 of 82
25 Project handbook - section Packing category VK 2: Cardboard box Small and spare parts for transport within Europe, or air freight shipment, should be packed in stable cardboard boxes of standard design, provided that their dimensions are suitable Note: Do not use Card boxes for overseas shipment! From a gross weight of 5 kg, the boxes are to be surrounded by steel or polyester bands From 30 to 1000 kg gross weight, one-way or Euro pallets must be installed under the boxes Over 1000 kg, special pallets must be used that have the required carrying capacity Generally, pallets or special pallets must be used that were treated according to IPPC standard Fig 2 Example: Cardboard box Page 25 of 82
26 Project handbook - section Packing category VK 3: Wooden supports This packing category must be combined with packing category VK 1 (shrink-wrap in PE foil) Application: For cylindrical vessels or similar goods All openings must be sealed watertight, eg by means of plugs, metal or plastic protective caps and/or larger openings by means of blind flanges (wood or steel) Vessels and apparatus with their own support bearings must be provided with min 30 mm thick wooden supports as slide protection Fig 3 Example: Design of the supports 115 Packing category VK 4: Pallets This packing category must be combined with packing category VK 1 (Shrink-wrap in PE foil) For goods that cannot be packed in boxes, due to their size, pallets or suitable wood structures must be made in order to allow transshipment by means of forklifts Preferably, four-way flat pallets of wood, 1200x800 mm (EURO pallet) according to ÖNORM A 5300 or DIN are to be used For packed goods up to 1000 kg and max Pallet size - 40 mm (the pallets or wood structures must be at least 20 mm larger that the work piece to be packed in order to avoid damage) Page 26 of 82
27 Project handbook - section The wood used to manufacture the packing must be treated according to IPPC standard The parts are fastened by means of suitable steel band, plastic band or screws, so that slipping is impossible The parts must be protected appropriately from damage by the means of fastening In any case, there must be s suitable sealing layer between the goods and the packing woods, eg aluminum foil, antiskid mat or the like Fig 4 : Recommended number of support woods for pallets: Page 2 of 82
28 Project handbook - section Packing category VK 5: Standard drum Application: for cable on cable drums The cable ends must be preserved and routed to the inside, if possible Fig 5 Example: Drum design 11 Packing category VK 5a: Seaworthy drum packing Cables on cable drums for seaworthy packing must be packed using packing category 5 In addition, this packing must be combined with packing category VK 1 (shrink-wrap in PE foil) and packing category VK 8 (seaworthy crate with lining) 118 Packing category VK 6: Sheathing Sheathing can be made by means of wooden laths or lamella packing (Fig 6) 1181 Lamella packing The lamella packing is to be fixed by means of adhesive tape 1182 Wooden laths If wooden laths are used, care must be taken that a watertight sealing layer is installed between the wooden laths and the component The lath width must be selected according to the component diameter, but max 0 mm The wooden laths must be fixed by means of zinc anodized steel band or plastic bands Page 28 of 82
29 Project handbook - section Fig 6 Example: Sheathing of a turbine shaft 119 Packing category VK : Standard crate (without lining) The crate must always be designed in accordance with the total gross weight 1191 Crate bottom Longitudinal skids min 80 mm thick, floor boards min 24 mm thick For crates > 5 t and/or width > 2000 mm: square face timber bolted (through bolt with washer + nut) Crosswise skids to 5 t, 100 x 100 mm thick, from 5 t, 100 x 120 mm thick, must be bolted to the longitudinal and/or intermediate skids and securely nailed several times Crosswise skid securing wood: with as for longitudinal skid, height 100 mm, length mm, forklift width must be left free From 2 t: Longitudinal skid securing wood and/or bar: height as for longitudinal skid, width 80 mm, length according to crate width Special note for heavy lift packing 5 t: For heavy lift packing, crates must be provided with special heavy lift hardware and/or crate angles 1192 Side walls, face walls and cover Must be designed according to requirements For crates > 2 t and/or length > 3000 mm, truss-type stiffening is required 1193 Stack pressure Strap frames, diagonals and cover woods must be designed for a stack pressure of min Page 29 of 82
30 Project handbook - section 2 GENERAL DOCUMENT t/m² The cover woods incl cover supports must be installed at distances of mm and nailed to the side walls Fig Typical: Crate and Cover design of packing case without Preservation protection Cover design Crate design Page 30 of 82 Fig 8 Typical: Case with vertical board arrangement and vertical ledgers
31 Project handbook - section Packing category VK 8: Seaworthy crate (with lining) Page 31 of 82
32 Project handbook - section Fig 9 Typical Packing case with preservation protection The crate must always be designed in accordance with the total gross weight 1111 Packing category VK 9: Seaworthy crate (with lining and shrink wrap) Page 32 of 82
33 Project handbook - section Crate and cover design According to packing category VK Goods The goods are to be shrink-wrapped in aluminum foil Edges or projecting parts must be padded adequately Distance between foil and crate wall mm Direct contact of the aluminum foil with the crate floor must be avoided (install air cushion foil, foam material, etc) After processing After processing of the foil, the enclosed air must be exhausted (vacuum approx 6 mbar) and a leakage test to be carried out For absorption of humidity, desiccants of sufficient quantity (silica gel, etc) must be added, and/or suitable measures must be taken so that a corrosion preventing room climate is created In order to prevent contact corrosion, the desiccant must be attached in such a manner that direct contact to the packed good is not possible The desiccant packs must be guaranteed to be dustproof and so stable that they will not open under any circumstances Packed goods The packed goods must be secured in such a manner inside the crate against horizontal forces that may occur (tilting, marshaling shock, impact, etc) that such loads are withstood without damage They may be secured by bolting to the skids and/or the floor, fixing to the floor by means of frames, padding between the device and crate wall, etc Goods that may vibrate Goods that may vibrate must be secured in such a manner (using rubber-metal connection, spring elements, etc), that the mass and exciting forces cannot reinforce each other and resulting damage is prevented Page 33 of 82
34 Project handbook - section 2 Fig 10: Internal packing and bolting Packing category VK 10: Shipper's own container In contrast to the shipping container, the shipper's own container is considered to be am means of packing, since the goods can be stored in it until used For sea transport, box containers should be provided if possible For optimum packing and handling, the goods are to be packed on bases that are pushed into the container by means of a forklift Page 34 of 82
35 Project handbook - section Fig 11 Typical: Shipper's own container Fig 12: Example for a container floor Page 35 of 82
36 Project handbook - section 2 GENERAL DOCUMENT Fastening on the container floor On the outside long sides of the container floors, eyes are attached through which 36 mm polyester attachment belts can be pulled to tie down the parts If the floor is filled (maximum approx 10,000 kg/floor) it must be covered by PE shrinkwrap foil (see Packing category VK 1) to protect the goods from moisture and dirt Fig13: Eyes in the container floor Page 36 of 82
37 Project handbook - section 2 Fig14: Example for a container floor In order to remove the floors from the container at the destination, 2 tie straps or cables must be attached on the floor face on the side towards the container door The tie straps are designed such that commercial shackles and ropes can be attached to them Example for tie straps on the container floor Page 3 of 82
38 Project handbook - section Fig 15: Completely loaded container Heavy lift hardware (attachment plates and crate angles) Crates with a gross weight of more than 5 t have hardware of steel on the bottom and top edges in cable position (sheetmetal thickness dependent on the weight, but min 3 mm) Attachment plates are to be designed and attached according to the total weight of the loaded crate The crate angles are intended to protect the crate from damage during attachment to a crane by cables, chains, etc Fig16: Attaching heavy lift hardware Page 38 of 82
39 Project handbook - section Preservation of Pipes 12 Preservation and packing of pipes for transport to site This instruction for preservation of pipes is based on the VN Dispatch Preservation of Machine Parts, which is attached to this document at the end for reference 1211 Pipes of stainless steel: Independently of the intended use, such pipes are not preserved However, take special care to avoid direct contact between stainless steel pipes and carbon steel pipes during transport and storage 1212 Pipes of carbon steel: Precision steel pipes to DIN 2391: They have to be ordered (material order sheet) oiled on the inside and outside and have to be stored under roof when delivered They are shipped in condition as supplied to the site Pipes < inside dia 50 to DIN 2448, DIN 2440 and DIN 2441: Anticorrosive agent applied neither inside nor outside Unless the Purchaser makes special requirements (eg galvanizing), the pipes if used for water lines are delivered to the site without being preserved on the inside Pipes used for oil or air lines (not for oxygen lines) are to be ordered (material order sheet) in oiled condition (oiled on the inside) unless special requirements are made and are to be stored under roof Pipes > inside dia 50 to DIN 2448, DIN 2440 and DIN 2441: Pipes used for water, oil or air lines (not for oxygen lines) are delivered in condition not treated on the inside and outside to the site unless the Purchaser makes special requirements The pipes have to be closed at their ends by means of plastic cups In addition to the stipulation given in this document, it is recommended in any case to Page 39 of 82
40 Project handbook - section 2 GENERAL DOCUMENT close the pipe ends by means of plastic cups to prevent them from dirt inside 122 Packing of pipes For detailed instruction for packing of pipes see paragraph 13 of this document In addition to these standards, the following packing of pipes is recommended: - Up to 40 mm diameter: Packing in cases - From 40 mm to 100 mm dia: Packing in crates with fully closed narrow sidewalls - From 100 up to 168,3 mm dia : Bundling - From 163,8 mm diameter: To be packed individually The bundle shall be hooped with at least 20 mm wide zinc-anodized steel straps On a length of 6 m, 3 hoops shall be used Fig1 Example: Typical Pipe Bundle Note: Both ends of the pipe bundles have to covered by appropriate means (net, etc) to Page 40 of 82
41 Project handbook - section 2 prevent the inner pipes from slipping out during handling GENERAL DOCUMENT Packing standard and construction of packings This instruction for packing of Turbine, Generator, Governor and BOP -components is based on the VN 15-1 Packing Standard This standard is attached for reference The following requirements shall be applied for packing of the parts: For overseas shipment all parts shipped to site shall be seaworthy packed in suitable wooden boxes as defined below Before packing, the parts shall be protected as defined below Raw material as steel plates or prefabricated parts to be fabricated at site may be transported fixed on gratings or frames Open ends of steel pipes shall be closed by plugs Shipping in Containers is only allowed if approved by Voith Parts belonging to one assembly shall be typically packed in one box or package If this is not possible, it shall be possible to easily identify the different packages used for one assembly Boxes shall not be used for outside storage except in transit For long term storage of parts special conditions apply Spare parts are always to be packed separately 131 Packing list Two copies of the packing list shall be affixed to the packing internal wall, while copies of the technical documents as requested by the purchase conditions will be separated contained in a waterproof sealed envelope and placed into the package itself outside the covering of the material An additional copy of the packing list contained in a similar envelope as said above shall be placed beneath the metal tag showing PACKING LIST to be externally affixed to the package See also requirements in paragraph 4 and paragraph 1 for DISPATCH AND MARKING INSTRUCTION in this document Page 41 of 82
42 Project handbook - section Load assumption Fig 18 Page 42 of 82
43 Project handbook - section Fig 19 Example: acceleration forces on high seas due to rolling and stamping of the ship Rolling angles of up to 30 can occur Page 43 of 82
44 Project handbook - section Loads due to crushing in stacks Page 44 of 82
45 Project handbook - section Horizontal Loads Page 45 of 82
46 Project handbook - section Vertical Loads Stresses through falling and vibrations Page 46 of 82
47 Project handbook - section Transverse forces during crane handling Fig 20 Page 4 of 82
48 Project handbook - section Tilting stresses Fig Centre of gravity indication Page 48 of 82
49 Project handbook - section Size and weight of package During the construction of packages, dimensions shall be reduced as much as possible to comply with the following package sizes and weights as established by national and international standards: Land transport: x 230 x 230 m (length x width x height), weight: 20,000 kg 134 Sizes and weight limitations Packages will be limited to the following values: Note: In case the dimension and / or the gross for one packing are exceeding 1180 x 230 x 230 m (L x B x H) and / or 20 ton, the sub supplier has to inform Voith Hydro at least 60 days ahead of the ex works date and provide the following information, which shall be binding and in case of deliveries less than 60 days, the notification should be made immediately after placement of the order: - External dimension of the packed unit in the position, which it is to be transported, - Longitudinal and side view, - Gross and net weight in kg, - Centre of gravity in longitudinal and transverse directions, - Sling points (and special criteria to be considered), - Transport sketches, Page 49 of 82
50 Project handbook - section 2 GENERAL DOCUMENT Type of packing planned or required (Clearly plotted), - Material pertaining to different orders (POR) shall be packed together 135 Construction of packings 1351 Standard packing The construction of packing cases shall as a minimum meet the features shown in the sketch of case and crate in this document, and the particular requirements of each type of packing If bottom longitudinal beams can not be obtained from a single wood element, a single joint will be allowed between two beam segments of equal section The joint can be either butt, or end lap, or flute beak type and shall effect the beam position subject to minimum load The joint shall be bolted* and nailed* with small wooden side reinforcement beams * Consider the requirements stated in paragraph 164 and Particular packing Unless otherwise provided by above paragraph the possible minimum thickness of boards may be established as per the following table: Page 50 of 82
51 Project handbook - section 2 GENERAL DOCUMENT Alternative to board thickness wood 22/24mm, plywood boards can be taken with a thickness of 10/13mm according ton DIN/CODE WFU 100 DIN 6805 Part WOODEN CRATES (TYPES AND CONSTRUCTION ELEMENTS) For packing of metal equipment with length, width and height lower than 5 x 15 x 15 m or exceeding only one of the above said dimensions, the crate shall be used Refer to sketches for the construction, typology and element of create The crate will have a dead freight surface equal to 50 % The use of crates constructed with full heads will be provided for the following materials: - Carbon steel pipes - Conduit pipes - Stainless steel pipes - Prefabricated piping All the openings of the prefabricated piping shall be suitably protected with wooden or plastic plugs or cups to be taped Size of boards to be used for the construction of the crate will be minimum widths from 120 mm up to 180 mm maximum, minimum thickness not less than 25 mm Any knots on the board may be fixed by using bonding agent or by adequate plugging No pass-through or connected knots and substantial cracks are permitted A crate with net capacity over 2,000 kg shall have steel plates on the lifting pints A crate having a width higher than 2 m has to be provided with suitable sized steel angle bars on upper corner of the top cover to avoid abrasion or cracks caused by slinging ropes or chains The material shall be fixed on the crate bottom beams using either bolts, tie rods or suitable stirrups Page 51 of 82
52 Project handbook - section Fig 22 Typical Crate with Bottom Structure and open narrow sides 13 Wooden cases/plywood cases (construction elements) Refer to sketches for the construction, typology and elements of the case and top cover Boards to be used in manufacturing walls and top cover of the case shall be from 120 mm min up to 180 mm maximum in width and the minimum true thickness not less than 25 mm The cover will be screwed to case beams Any knots on the board may be fixed by using bonding agent or by adequate plugging No pass-through or connected knots and substantial cracks are permitted Polyethylene sheets of 02mm minimum thickness shall be used for the internal lining of the case walls The case lid shall be designed to prevent water penetration and shall therefore be lined on the inside with polyethylene or aluminum compound foil A layer of hard board, plywood or plastic shall also be nailed to the lid to prevent the formation of water pockets Materials inside the group of goods, marked according to the conservation instruction and other material sensible to humidity, even if not listed, shall be placed into a heat hermetic barrier as described in this document Page 52 of 82
53 Project handbook - section Note: This barrier shall contain an appropriate quantity of dehydrating salt to keep materials under environmental conditions with a humidity rate lower than 35 % at 20 ºC for two years The remaining material has to be protected for one-year duration A case with net capacity over 2,000kg shall be provided complete with steel plates on the lifting points A case having a width higher than 2m shall provide suitable sized steel bars on upper corner of the top cover to avoid abrasion or cracks caused by slinging ropes or chains Fig 23 Typical Packing case with preservation protection, floating packing 138 SKID/SUB-Skid Arrangement for cases and crates Page 53 of 82
54 Project handbook - section 2 GENERAL DOCUMENT A minimum of 3 skids has to be provided for case and crate widths of 100 cm to 240 cm The number of skids, their position and spacing is dictated by the fixing possibilities of the packed item to the case/crate bottom and the position of the centre of gravity The skid dimensioning has to be adapted to the weight and the form of the paced item The sub-skids have to be placed in a way that transshipment/relocation of the case/crate can be performed by a forklift The minimum height of the sub-skids is 10 cm Fig 24 Typical Bottom Structure Fig 25 Typical Skid for pipes designed of steel Page 54 of 82
55 Project handbook - section When using sub-skids (60mm to 80mm thick) they have to be bolted or securely nailed to the longitudinal and/or intermediate skids Fig 26 Typical Skids designed of wood Page 55 of 82
56 Project handbook - section Wooden saddles/skids (types and construction elements) Saddles/skids entirely constructed with full beams of minimum width dimensions as listed below shall be used for packing of equipment with length and height over 5 x 15 x 15 m: - < 2000 kg net weight 200 mm to 6000 kg net weight 300 mm to kg net weight 400 mm In case the equipment is not self-bearing, the number of saddles has to be defined by the Engineering Saddles/skids have to be manufactured in such a way as to minimize the equipment height from the ground Saddles/skids have to be fastened with steel hoops (minimum width 50 mm, 3 mm thick) and connected to the Saddles/skids by tie rods An adequate protection between hoops and equipment has to be provided Fig 2 Typical Packing of equipment on Saddles/skids Page 56 of 82
57 Project handbook - section Fig 28 Typical Wooden slide (for piece weight up to 30 tons) Transport stand for formed sheet steel elements Areal structures have to be loaded on transport stands designed such that transshipment/relocation is possible with standard lifting gear (crane and fork lift) without the need of especially constructed traverses Sheet steel has to be additionally fastened using clamps Fig 29 Typical Example of wooden slides on a Turbine Shaft Page 5 of 82
58 Project handbook - section Page 58 of 82
59 Project handbook - section Packing and shipping procedure Machine parts and other components with nozzles, or openings have to be plugged with suitable fixed plastic cups or wooden disks Cable passing holes for terminal boards of the electric motors shall be sealed with plastic cups The material shall be fixed to the case bottom beams using either bolts or the rods or by other adequate stirrups All valves shall be plugged with suitable fixed plastic cups or wooden disks The cases shall be braced and reinforced to withstand any load (static or dynamic) likely to occur during transportation by rail, road or ship (rail: 4g, road: 12g, ship: 11g) : For detailed information see paragraph 132 Load assumption Measures shall be taken to prevent the item from shifting within the packed unit, ie screwing together, bolting to the bottom of the case, etc Exclusively wood of quality class II / III (pine/spruce) according to DIN 40/4 part 1 and 2 may be used for the production of cases The boards for the outer surfaces must have a thickness between 24 and 30 mm, depending on the type, dimensions and weight of the goods to be packed The boards have to be butt joined and nailed One of the crucial criteria of the case design is their capability to be stacked, ie sufficient internal bracing using squared timber and diagonal struts have to be provided The case has to be provided with skids and sub-skids (for the attachment of the lifting cable/ropes) Number and thickness of the skids must match the total weight, the length and width of the packed item For gross weights above 5 tons, the sling points (bottom/side and side/cover) have to be reinforced by additional angled sheet steel (at least 3mm thick) in order to prevent the cables/ropes from being constricted For cases having an overall weight of 1,000kg and above, the front timbers have to be permanently bolted to the case skids The packed item has to be protected against any displacement by appropriate measures (screw connection with each other, bolted down to the case bottom, etc) The internal case walls have to be lined with barrier sheeting (eg jute cardboard or tarred brown cardboard) Page 59 of 82
60 Project handbook - section The case cover hast to be prepared such to prevent any ingress of water For this reason, the case cover produced has to be lined with polyethylene or aluminum compound film Hold the lining in place by hard board, plywood or plastic boards (nailed against) to prevent the formation of water pockets (as shown in the picture below) Never store ready-made cases unprotected in open air If sheltered or roofed cover storage place is not available, they have to be covered by tarpaulin Fig 30 Negative Example: Ingress of water due to insufficient or damaged lining of the packing box 16 Packing materials 161 Quality of wood The basic characteristics of the wood must meet the following requirements: - Dryness of approx 30 % - Free protruding knots or defects larger than 1/3 of the width of the boards : - Free splits longer than 25mm : - Flaw pieces : are not admitted - Minimum width of boards: 12 cm - Second-hand timber is not allowed to be used Page 60 of 82
61 Project handbook - section All wood used (crates, pallets, dunnage bars, etc) must be treated according to IPPC Standard and marked accordingly Associated standards 1611 ISPM 15 GUIDELINES FOR REGULATING WOOD PACKAGING MATERIAL Many countries have put quarantine regulations in place to protect their native forests from the introduction of wood pests In order to prevent the proliferation of differing import regulations, the International Plant Protection Convention (IPPC) Secretariat, part of the Food and Agriculture Organization (FAO) of the United Nations, has issued ISPM 15 (International Standards for Phytosanitary Measures) "Guidelines for Regulating Wood Packaging Material in International Trade" The standard ISPM 15 also gives GUIDELINES FOR REGULATING WOOD PACKAGING MATERIAL IN INTERNATIONAL TRADE and describes phytosanitary measures to reduce the risk of introduction and/or spread of quarantine pests associated with wood packaging material (including dunnage), made of coniferous and nonconiferous raw wood, in use in international trade OUTLINE OF REQUIREMENTS Wood packaging material made of unprocessed raw wood is a pathway for the introduction and spread of pests Because the origin of wood packaging material is often difficult to determine, globally approved measures that significantly reduce the risk of pest spread are described NPPOs (National Plant Protection Organization) are encouraged to accept wood packaging material that has been subjected to an approved measure without further requirements Such wood packaging material includes dunnage, but excludes processed wood packaging material Page 61 of 82
62 Project handbook - section 2 GENERAL DOCUMENT Procedures to verify that an approved measure, including the application of a globally recognized mark, has been applied should be in place in both exporting and importing countries Other measures agreed to under a bilateral arrangement are also considered in this standard Wood packaging material that does not comply with the requirements of this standard should be disposed of in an approved manner The key features of ISPM 15 are given in the table below for reverence: The key features of ISPM 15: ISPM 15 applies only to solid wood, with derived timber products and solid wood thinner than 6 mm (according to the EU Harmonized System) being exempt Treatment of the packaging by approved measures, which include heat treatment (HT) to a core temperature of 56 C for at least 30 minutes, for example by kiln drying (KD), provided that the above-stated specifications are achieved Chemical pressure impregnation (CPI) is approved only if the required HT specifications are achieved, which is not generally the case Another measure is fumigation with methyl bromide (MB) depending on concentration, duration and temperature Permanent and legible marking of the packaging must be provided on two opposite sides of the package The mark is composed of the ISO 3166 two letter country code (eg DE for Germany), the regional identifier (eg NW for North Rhine-Westphalia) and a registration number issued by the regional phytosanitary authority to the packaging container manufacturer, the packer or the consignor (unique number beginning with 49) The treatment method is denoted by the abbreviation HT for heat treatment or MB for fumigation with methyl bromide The letters DB may also be included where debarking is required Figure 1: Example of IPPC mark IPPC symbol Country code to ISO 3166, eg DE for Germany Regional identifier, eg NW for North Rhine-Westphalia Page 62 of 82
63 Project handbook - section Registration number, unique number beginning with 49 Treatment method, eg HT (heat treatment), MB (methyl bromide), if applicable, DB (debarked) The use of debarked wood may be required Official phytosanitary certificate is no longer required The phytosanitary authorities can provide information about the IPPC standard such as the countries to which it applies, the date from which it applies and its scope Page 63 of 82
64 Project handbook - section Page 64 of 82
65 Project handbook - section At the end of this FSEM, a copy of this standard is attached for reference Page 65 of 82
66 Project handbook - section Foils Only film products which are used in the packing industry for the manufacture of film shrouds are allowed (see anticorrosion protection with desiccants item 5) The type of film material has to fulfill the highest quality specifications, unlike film material that is used only for covering purposes to provide a hood when using the VCI method (see item 53) There are different types of film materials: 1 Transparent shrink-wrap foils HS Shrink films as VCI corrosion protection film - based on polyethylene with VCI active substance integrated in the polymer matrix - are used Both sides of the film provide effective VCI protection (example: EXOR VALENO FI) Below a typical date sheet of such foils is given for information 2 Aluminum composite foil designed as sealing layer foil Page 66 of 82
67 Project handbook - section Page 6 of 82
68 Project handbook - section Padding and filler materials Padding paper, air bags, air cushion foil, foam foils and foam mats are to be used as filler material ATTENTION: Styrofoam chips must not be used generally Page 68 of 82
69 Project handbook - section 2 GENERAL DOCUMENT The use of hygroscopic filler and padding materials (eg wood wool, hay, straw, waste paper, etc) to fill out empty spaces and/or for padding is not allowed Page 69 of 82
70 Project handbook - section Page 0 of 82
71 Project handbook - section Bolts and screws Galvanized steel bolts shall be used for fitting equipment at any type of packing and fitting the bottom beams of the packing Galvanized screws shall be used to fix the covers of the crates and cases Page 1 of 82
72 Project handbook - section Nails Flat head nails have to be used and shall have enough length to bend over inside the packing Note: For load carrying structures of packings no nails must be used, but bolts or spindles should be used instead Especially for shipments into warm-dry counties, or in case of a long storage period, the shrinkage of the wood due to reduced humidity can cause that the nails become loose Page 2 of 82
73 Project handbook - section Dispatch and marking instruction for handling of the goods 11 General For handling and lifting of the packing-boxes, at last the indications listed below have to be on the packing The texts shall be in the manufacturing country idiom and in English, or in one more idiom else, if required by the customer Page 3 of 82
74 Project handbook - section 2 GENERAL DOCUMENT Lifting device localization; - Support points for the transport; - Locals for the package anchoring during the transportation; - Inspection table for the desiccants; - Localization of the desiccants inspection opening; For identification, each packing have to be marked as described below: The markings on the package consist of the: a) Weight details b) Dimensions c) Notes on handling of package d) Package No e) Other necessary markings f) Machine No: The weights, dimensions and markings indicated on the package provide information on the correct selection and use of hoisting gear, handling and treatment during transport and storage of the package The Machine No permits clear identification of packages bearing the same order No and belonging to a specific machine The Package Serial No is assigned to each consecutive package bearing the same Machine No Note: The Supplier's Reference No is the same as the Package No and Dispatch Note No and remains unchanged even for part shipments The positive identification of packages is possible only with the complete Package No which appears on the dispatch note and on the packing list The packing List can consist of several pages, depending on the scope of the shipment 12 Labeling Two different kind of labels have to be fixed on each colli: Page 4 of 82
75 Project handbook - section Project related with client name etc as per the contractual stipulations: To be adapted for the project and given later This marking shall be made min on two (2) sides of the packages The first five lines are self-explanatory Storage Code: Explanations to Storage Code please see paragraph 10 Do not use abbreviations! Shipment No: Shall be as per shipping order Package No: Shall be as per shipping order or consecutive numbering specifically assigned to a supplier Gross Weight: Gross weight in kg Net Weight: Dimensions: Net weight in kg Package dimensions in mm, length x width x height Page 5 of 82
76 Project handbook - section Project related out of the DIA-AL System of Voith Hydro for internal purposes This marking shall also be made on four (4) sides of the packages 123 Shipping Instruction: Please refer to the General Shipping Instruction for Subsuppliers of Voith Hydro GmbH & CoKG) This document describes the related document requirements (kind and due dates in General) 13 Cautionary Symbols Cautionary symbols as well as special handling instruction shall be made in the following manner on all four (4) sides of the packages, as far as appropriate Page 6 of 82
77 Project handbook - section In paragraph 14, an example is attached for information Symbol conform DIN Designation International Standard Keep dry ISO 80 Symbol ISO 000 / No 0626 Keep away from heat ISO 80 Symbol 4 ISO 000 / No 0624 Use no hooks ISO 80 Symbol 2 ISO 000 / No 0622 Center of gravity ISO 80 Symbol 8 ISO 000 / No 062 Clamp here ISO 80 Symbol 12 ISO 000 / No 0631 Sling here ISO 80 Symbol 6 ISO 000 / No 0625 Fragile handle with care ISO 80 Symbol 1 ISO 000 / No 0621 Page of 82
78 Project handbook - section This way up ISO 80 Symbol 3 ISO 000 / No 0623 No hand truck here ISO 80 Symbol 9 ISO 000 / No 0629 Do not destroy barrier Electrostatic sensitive device IEC 41 No 5134 Temperature limitations ISO 80 Symbol 13 ISO 000 / No 0632 Do not use fork lift truck here Stacking limitation ISO 80 Symbol 11 ISO 000 / No 0630 Tear off here - Protect from heat and radioactive sources ISO 80 Symbol 5 ISO 000 / No 0615 Page 8 of 82
79 Project handbook - section Sealed packing with desiccants Open here to check desiccant Marking of the flap witch gives access to the desiccant - ARRANGEMENT OF SYMBOLS ON BOXES: Fig 1 Example for the arrangement of the symbol center of gravity Symbols DIN registration No 00463, 00464, 00465, 00469, 0040, 01200, 0203, 02902, 02904, 0325 Considering the regulations of the transport carriers the symbols are to be provided at the top left of the marking according to DIN , part 2 In the case of simultaneous use of several symbols they are possibly to be arranged beside each other Symbols DIN registration No Fig 2 Example for the arrangement of the symbol apply slinging material here The symbol is to be arranged such that the symbol clearly defines the center of gravity of the packed piece Symbol DIN registration No The symbol is arranged on those sides of the packed piece where slinging materials have to be applied (see fig 2) Page 9 of 82
80 Project handbook - section Fig 3 Example for the arrangement of a temperature range or the upper or lower temperature limits value Symbol DIN registration No 0041 and The symbols are to be arranged on the side not permitted for handling with the fork lift truck and/or position of the packed piece Symbol DIN registration No 0046 The symbol is to be arranged on the side facing the fork lift truck driver Symbol DIN registration No The symbol is to be provided with the addition C for a temperature range or with the addition C max or C min for the upper or lower temperature limit value (see fig 3) Fig 4 Example for the arrangement of the information kg max Symbol DIN registration No Above the symbol the addition kg max is to be arranged Apart from stating kg max the permissible stapling load is to be given (see fig 4) Page 80 of 82
81 Project handbook - section Marking of Packages; Directive for Export Packaging Designation symbol Legend Contract No Package No Destination Consignee Colli - No Quantity of Colli Port of destination Country of origin Gross-weight (Kg) Net-weight (Kg) Measurement (cm) Guide Marking Informatio n Marking Case showing symbols and instructions (example) Legend for Shipping of Packages (Example) Contract-no: Shipping marks: Destination: 94ML DE Huangpu, China; Guangdong Machinery I/E Kowloon Bay Equipment for Guangzhou Pumped Storage Power Plant C Package-no: V Gross-weight: Net-weight: Measurement: Kg Kg 244 x 101 x 99 cm Main item no: 125 Indoor storage: Page 81 of 82 S3
82 Project handbook - section Packing Instruction for special parts The following parts are considered as Special Parts and special care have to be applied to those components These parts are attached to the inquiry resp purchase order as separate document: 19 Attached standards Adobe Acrobat Document VN Packing standard Adobe Acrobat Document VN Preservation and storage VSN Preservation of machine parts Adobe Acrobat Document Adobe Acrobat Document International Standard for WOOD PACKING MATERIAL Page 82 of 82
Guidelines for Packing
ABB AG Calor Emag Medium Voltage Products Guidelines for Packing 19.04.2011 Guidelines for Packing 1 Gas-insulated switchgear type ZX Vacuum circuit-breaker Embedded Poles Vacuum interrupter Components
E. INTERNAL PACKAGING
ANTI-CRRSIN MEASURES E. INTERNAL PACKAGING 1. ANTI-CRRSIN MEASURES During transport, handling and storage especially during overseas shipping more intensive stresses occur, which are often not sufficiently
BUILDING MATERIALS, Wood, Laminated (Page 1 of 3) Viz.: Rafters; Arches; Beams; Joists; Timbers or Planks, structural or roof.
BUILDING MATERIALS, Wood, Laminated (Page 1 of 3) Viz.: Rafters; Arches; Beams; Joists; Timbers or Planks, structural or roof. 1155 & 4155 LCL: Applies to all freight in less than container load quantities.
Guidelines for Packing
ABB AG Calor Emag Medium Voltage Products Guidelines for Packing 19.04.2011 Guidelines for Packing 1 Gas-insulated switchgear type ZX Vacuum circuit-breaker Embedded Poles Vacuum interrupter Components
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
39HQ Airovision Air Handling Units
39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport
GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY
GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY July 2008 1.0 SCOPE These guidelines describe the way in which air conditioning units shall be installed or replaced
INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles
INSTALLATION RECOMMENDATIONS Outdoor Rubber Tiles Prior to Installation: The Outdoor Rubber Tiles and accessory transition pieces intended for this installation have been shipped to you via a freight carrier
50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance
02/15 Labko GRP cesspools Instructions for installation, operation and maintenance Reliable solutions Wastewater treatment systems Contents 1 LABKO CESSPOOLS... 3 1.1 GENERAL... 3 1.2 IMPORTANT TO KNOW
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER
PAAM COMMERCIAL PRIVATE LIMITED
METAL PACKAGING We at Paam Group have been providing vast range of packaging products to our customers based on their preferences, needs and specifications. We provide all the materials required in metal
YFS Automotive Systems, Inc. Supplier Packaging Guidelines
Table of Contents 1.0 Introduction... 2 2.0 Supplier Responsibilities and General Guidelines... 2 3.0 Packaging Data Form... 2 4.0 Expendable Packaging... 2 5.0 Shipping Identification Labels... 3 6.0
INSTALLATION. General. Important Note. Design. Transport
General The roof trusses you are about to install have been manufactured to precise engineering standards. To ensure that the trusses perform as designed, it is essential that they be handled, erected
Rooflight INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Rooflight These instructions should be used for: Installing Permanent Trickle Ventilation: Constructing & Waterproofing a Timber Upstand Curb: Installing & Waterproofing Proprietary
HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
Installation Instructions
Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
COATING & WRAPPING OF UNDERGROUND PIPING
CONSTRUCTION STANDARD SPECIFICATION DOCUMENT NO :SEC-PJ-000-SPC-PI-008 TOTAL PAGES : 8 Page 1 of 8 CONTENTS 1. SCOPE 2. DEFINITION 3. CODES AND STANDARDS 4. MATERIALS Page 2 of 8 1. SCOPE This specification
Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales
Installation information METTLER TOLEDO MultiRange Floor scales / Pit scales KC300/KCS300 KC600/KCS600 KD600/KD1500 KE1500/KE3000 KES1500/KES3000 KG3000/KG6000 KN1500 Floor scales / Pit scales Contents
-1- SPECIFICATIONS 002085 CONE SETTER PLATFORM ATTACHMENT INDEX
-1-002085 CONE SETTER PLATFORM ATTACHMENT INDEX I. GENERAL EQUIPMENT : A. Intent Statement B. Cone Setter Platform II. III. 1. Understructure Frame 2. Mounting Components 3. Paint 4. Basket 5. Labels 6.
TARIFF CODE and updates standard
TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of
Industrial Guideline nr. 2
Industrial Guideline nr. 2 OFFSHORE CONTAINERS Purpose Provide guidance for the safe use of offshore containers in the Dutch mining industry taking in account Dutch legislation and European standards.
The entire document shall be read and understood before proceeding with a test. ISTA 3B 2013 - Page 1 of 35
Packaged-Products for Less-Than-Truckload (LTL) Shipment ISTA 3 Series General Simulation Performance Test PROCEDURE VERSION DATE Last TECHNICAL Change: NOVEMBER 2012 Last EDITORIAL Change: JANUARY 2013
Embedded Parts Introduction - Anchors
In the plant construction or process plants such as chemical, petrochemical, gas or power plants various disciplines are brought into contact and built on each other. Civil, mechanical, electro technical
James M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
Mark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
HORIZONTAL INSTALLATION
THERMO/SOLAR Žiar s.r.o. MANUAL FOR INSTALLATION PV SUPPORTING FRAMES HORIZONTAL INSTALLATION Technical alternation reserved A1410 1 12/2014 CONTENT ORD.NO. PAGE Mounting information 3 Mounting, flat roof
II. For Type B parts:...20 III. For Type C parts:...20 IV. For Type D parts:...20 V. For Type E parts:...20 5. Process Changes...
Table of Contents FORWARD... 4 1.0 INTRODUCTION... 5 2.0 PACKAGING DATA... 5 3.0 GENERAL REQUIREMENTS... 5 4.0 PACKAGING REQUIREMENTS... 6 4.1 Package Design...6 4.2 Part Cleanliness and Protection:...6
K2 STONE NATURAL VENEER
INTRODUCTION WHAT IS K2 NATURAL THINSTONE VENEER? Natural K2 Stone veneer is real stone, cut 1 inch thick, making it light enough to be installed as a veneer. Sometimes referred to as thin veneer, thin
After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE
86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is
Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...
Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information
Packaging Perishable Shipments
Packaging Perishable Shipments To help prevent spoilage and maintain product integrity, follow these instructions for shipping your perishable items via FedEx Express services. Preparing Perishable Items
Packaging Well packaged, perfectly delivered
Packaging Well packaged, perfectly delivered The TNT Express packaging solutions TNT Express endeavours to deliver your parcels in perfect condition and on time. But you yourself can also contribute to
Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized
Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized Gravity Solar System Installation Manual: This manual explains how to install a system of evacuated
SECTION 15140 - PIPE HANGERS AND SUPPORTS
Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the
Test Report No. C829QPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Westech Components Wuxi Co.,
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.
Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12
Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?
A Health and Safety Guideline for Your Workplace What is static electricity? What causes it? How is it hazardous? And, most importantly, how can it be controlled? All of these questions will be answered
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
I BEAM TRACK INSTALLATION
PDQ 0/700 FESTOON SYSTEM INSTALLATION AND MAINTENANCE INSTRUCTIONS INTRODUCTION The PDQ Festoon System was designed to run on one of three sizes of I-beams: S x., S8 x 8. and S x.. System trolleys must
Dock Hardware & Accessory Products Catalog
Dock Hardware & Accessory Products Catalog Product Page # Product Page # Angle Brackets/Clips 8 Back Up Plate 5 Backing Plate/Hurricane Stop 10 Carriage Bolt Sets 4 Chain Retainer 10 Connector Pin Set
GENERAL REQUIREMENTS AND COMMERCIAL PACKAGING
PAGE 1 OF 7 1. SCOPE GENERAL REQUIREMENTS AND COMMERCIAL PACKAGING 1.1 This standard establishes the general packaging requirements of item(s) for shipment to and from Lockheed Martin Space Systems Company
Packaging Perishable Shipments
Packaging Perishable Shipments To help prevent spoilage and maintain product integrity, follow these instructions for shipping your perishable items via FedEx Express services. Preparing Perishable Items
North American Regulations for packaging materials
North American Regulations for packaging materials The North American Plant Protection Organisation (NAPPO) has announced the implementation of a new regulation, applicable for all shipments arriving in
The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................
During severe flood events, such as those
Recommended Practice for Home Heating Oil Tank Flood Resistance During severe flood events, such as those occurring from Hurricane Irene and Super- Storm Sandy, many coastal and low elevation inland areas
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures
City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures SECTION 7201 - PURPOSE The purpose of this appendix chapter is to establish minimum prescriptive standards
Beam Load Ratings. Tandem Flatbed Trailers. M-52 (52K - 48 Tandem) 52,000# - 4 span 55,000# - 10 span 60,000# - 20 span 90,000# - 48 span
Flatbed Trailers Tandem Flatbed Trailers When quality workmanship, dependability and longevity are critical to your business, all coupled with the best manufacturer s backing in the industry, owner-operators
PTFE Slide Bearings 04/10 149
04/10 149 1.0 GENERAL INFORMATION In a wide range of applications, PTFE Slide bearings are superior to conventional expansion plates, rollers and rocker arm type supports. They support petrochemical plant,
Fire Barrier Duct Wrap 15A
3 Fire Barrier Duct Wrap 15A Commerical Kitchen Grease Duct Fire Protection System Product Data and Installation Instructions Compliance 1998 Edition Complies with International Mechanical Code Complies
NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK
ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within
Tundra Series Windows January 2016
Tundra Series Windows January 2016 New Construction Installation Instructions Nail Fin, J-Fin and Brickmold Aplications product. ATTENTION! Read and understand all installation instructions before installing
HYDRAULIC LIFT TABLE CART 2200-LB.
HYDRAULIC LIFT TABLE CART 2200-LB. OWNER S MANUAL WARNING: Read carefully and understand all MACHINE ADJUSTMENT AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
Operating Instructions
Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4
1000-LB. TRAILER JACK OWNER S MANUAL
1000-LB. TRAILER JACK OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious
Packing and Containers
Packing and Containers Presented By: Date July 18, 2006 Revision 3, Date 30 April 2006 An Overview of Packing Requirements and Different Types of Containers. Reviewed on 18 July 2006 Prepared By: Ted Hollanders
Part I: Store Display Pallets
Part I: Store Display Pallets Mini pallet base dimensions are critical to ensure the proper handling of product through our entire retail system and therefore they must be strictly adhered to. The top
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
Chapter 10 - Scaffolding Systems
Chapter 10 - Scaffolding Systems Contents Chapter 10 - Scaffolding Systems... 10-1 Check and Oil the Pump Jacks... 10-4 Set Pump Jack Brackets... Error! Bookmark not defined. Set Pump Jack Poles... 10-5
Best Barns USA Assembly Book
Best Barns USA Assembly Book Revised November 27, 2013 the Easton - R 12'x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This manual is copyrighted.
INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions
2100 AD 015 0009 Mirror Elevator Ball Nut Replacement Procedure
2100 AD 015 0009 Mirror Elevator Ball Nut Replacement Procedure Derek Guenther 1/28/2015 Rev. Purpose The purpose of this document is to describe the procedure necessary to replace one of the ball nuts
Guidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
MONDOATHENS BASKETBALL SET (Reference PK110)
MONDOATHENS BASKETBALL SET (Reference PK110) DESCRIPTION The MONDOATHENS backstop unit is mainly designed for multi-sports pavilions and installations where the highest-level basketball competitions are
DHL EXPRESS PACKING GUIDE. Protect your shipment with good and quality packaging
DHL EXPRESS PACKING GUIDE Protect your shipment with good and quality packaging INTRODUCTION Thank you for using DHL Express for your international express shipping needs. DHL is committed to delivering
Boiler Plan II Table of Contents
Cover Page Table Of Contents Introduction Parts List Additional Materials Assembly instructions Drawings 1-15 Boiler Plan II Table of Contents Introduction This will be a very rewarding project, if you
ENGLISH FORK GUIDE 2013
FORK GUIDE 2013 ENGLISH 1 With a brand which is synonymous with specialists in forest products handling attachments, BOLZONI AURAMO offers its expertise and market leading attachments for all requirements,
Division 9. SignaFlor Pad and Pour Flooring System
Division 9 SignaFlor Pad and Pour Flooring System SPECIFICATIONS Page 1. General... 2 1.1 Description 2 1.2 Quality Assurance 2 1.3 Submittals 2 1.4 Delivery and Storage 3 1.5 Warranty 3 1.6 Working Conditions
SAFE HANDLING OF PRECAST CONCRETE PRODUCTS
SAFE HANDLING OF PRECAST CONCRETE PRODUCTS Safety Handling of Precast Concrete Products The lifting of any precast product requires the use of special equipment and substantial planning and knowledge.
SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010
Best Barns USA Assembly Book Revised November 29, 2010 SAMPLE INSTRUCTIONS the Denver 12'x 12' or 12'x16' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775
Timber Decks. Technical Note. March 2007
Timber Decks Technical Note. March 2007 This Technical Note contains general information for residential timber decks and floor frame structures for veranda s, patios etc which are exposed to the weather.
Guide Specifications for Maple Flooring Systems
Guide Specifications for Maple Flooring Systems MFMA Guide Specification for Resilient Pre-Engineered Fixed Panel System Purpose This Guide Specification is designed to assist in the production of actual
Chapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS.
Austin City Code - Volume II TITLE 25 LAND DEVELOPMENT\CHAPTER 25-12 TECHNICAL CODES\ARTICLE 1: UNIFORM BUILDING CODE\25-12-3 LOCAL AMENDMENTS TO THE BUILDING CODE Chapter 36 - STRAW BALE CONSTRUCTION
RAUFOSS EXPLOSIVE COMPRESSION FITTINGS
INSTRUCTION MANUAL FOR RAUFOSS EXPLOSIVE COMPRESSION FITTINGS Box 7 2831 Raufoss Norway Tlf.: +47 61 15 17 87 Fax: +47 61 15 25 56 25 January 2013, rev 2 Available on www.vpmetall.no Page 1 CONTENTS GENERAL
SECTION 14 20 10 - FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL
SECTION 14 20 10 - FREIGHT & PARKING GARAGE PART I - GENERAL 1.1 SECTION INCLUDES [NOTE to AE: The following lists requirements that are specific to freight elevators. These requirements are in addition
How to Install Hardwood Flooring Over a Sub Floor
How to Install Hardwood Flooring Over a Sub Floor Installation Preparation Instructions Read the entire instructions before starting your project. 1) INSPECT EACH PLANK (see fig. a) Wood is a natural product
Installation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
Superform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
Clad Direct Glaze Window Installation Instructions
Clad Direct Glaze Window Installation Instructions Sill flashing and sealing: 2. An overview of the proper flashing sequence is shown in figure 1. Please read entire installation instructions carefully
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
SECTION 6. Glass Storefront Doors:
SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail
Preface nivtec.com 3
nivtec.com Preface nivtec.com 3 nivtec 4 nivtec.com Planning with an Eye for Details nivtec.com 5 prolight+sound 2012 6 nivtec.com Meeting Point Fair Booth nivtec.com 7 Our Preparations 8 nivtec.com Enable
Guidelines for Earthquake Bracing Residential Water Heaters
Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the
IBC Tote Containment Sumps
IBC Tote Containment Sumps DENIOS Provides More Models- and More Variety of IBC Totes Sumps than any other Manufacturer Painted, Galvanized, Stainless Steel, and Poly models available Models provide storage
1. Lay out 2 pieces of 7/8" tubing and mark for bending as shown. Remember that the bend is in the shaded area as shown below in Figure 1.
MINI BIKE PLANS Page 1 INTRODUCTION Before starting to build your Mini-Bike, be sure that you have all the parts shown on the material list. You will note that tubing has been used in the construction.
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
Supplier Packaging Guidelines. NACCO Materials Handling Group, Inc.
Page 1 of 26 Supplier Packaging Guidelines For Locations in North America NACCO Materials Handling Group, Inc. June 13, 2014 This is a controlled document with the electronic read-only domain, accessed
Sliding and Folding Door Fittings Sliding Door Accessories
Sliding door lock Toplock For 1- and 2-leaf sliding doors Suitable for toughened safty glass and laminated sheet glass Suitable for DIN left and DIN right Max. weight per door leaf 120 kg For glass thickness:
INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS
2009 Pella Corporation INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS Part Number: 80WH0100 Installation Instructions for Typical Wood Frame Construction.
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions