Multicare LE. Bed for critical care and ICU FOR HEALTHCARE
|
|
- Jennifer Webster
- 7 years ago
- Views:
Transcription
1 Multicare LE Bed for critical care and ICU FOR HEALTHCARE
2
3 The Multicare LE bed offers an optimal solution to problems during hospitalisation in critical and intensive care units. The safety of the patient, support of vital functions, prevention of pressure ulcers, lung complications and suitable working conditions for the staff are subjects to which the Multicare LE responds by its progressive attributes.
4 Integrated safety concept The Multicare LE bed is designed for hospitalised critically ill patients while ensuring the safety of patients with various risks. The bed offers the patient protection concept which removes the risk of a fall and other bed-related injuries. The key element of the safety system is the siderails which provide protection based on the individual needs of each patient. Further sophisticated bed elements monitor the patient s safety the automatic I-Brake and multi-zone Bed Exit Alarm. [01] VARIABLE SIDERAIL SYSTEM FOR INDIVIDUAL ADJUSTMENT The unique siderail concept optimises care and protection depending on the risk rate and the patient s current condition. If the patient is indicated as being confused and high risk of sustaining a fall then the three-section siderail combination can be applied the standard head and central siderail is supported by the Protector at the foot end of the bed. The bed therefore has siderails that run the entire length of the mattress platform. A bed equipped with split siderails without a Protector provides most patients with standard protection. [01] HEIGHT OF THE SIDERAILS Given the above standard parameters of the siderails (45 cm in height) the bed is compatible with active and passive anti-decubitus mattresses. [02] MINIMUM GAPS MAXIMUM SAFETY The concept of minimum gaps reduces the risk of injury of a patient trapped between individual parts of the siderails and meets the latest standards. Even if the backrest is adjusted the space between the siderails remains constant. The space between the gaps meets the requirements of the EN strict safety standard. [02] [03] BED EXIT ALARM The multi-zone Bed Exit Alarm is part of the fall prevention system on the Multicare LE bed. The sensor is activated the moment the patient moves close to the edge of the bed and warns the patient and medical staff of the potential danger and possible risk of a fall. 4
5 [03] [04] [05] [06] [04] FALL PREVENTION AT THE LATERAL TILT Electronic sensors prevent the activation of the lateral tilt if the siderails are not in the safety position. [05] I-BRAKE Coming as part of the basic bed equipment the automatic I-Brake minimises the risks that may arise if the bed brake is not on. If the bed remains unbraked and is connected to the mains the I-Brake is automatically activated a minute later. [06] NURSE CALL The nurse call function prevents any dangerous situations by calling for the nurse s prompt assistance in urgent cases of patient care. 5
6
7 Serving nurses NURSING IS A PROFESSION that comes with a high risk of injury and back pain. The main cause is handling heavy loads patients. The bed s sophisticated functions can make these procedures significantly easier. [01] LATERAL TILT The lateral tilt turns the patient on his/her side with minimum physical effort. This function signifi cantly reduces the physical strain of nurses when handling the patient and removes the risk of work injury and back pain. It saves the time required for performing routine nursing work, provides more effective prevention of pressure ulcers and helps avoid complications in patients with lymphedema and facilitates post-operative drainage. It is easy for nurses to set the lateral tilt and safe for the patients. [01] [02] EASY TRANSPORT The fi fth castor makes it signifi cantly easier to manoeuvre the bed, stabilise the steering direction and makes it easy to turn the bed. Once the bed has been moved, the fi fth castor retracts to the undercarriage. It does not obstruct underpass equipment such as the C-arm, server or lift and cleaning. The ergonomic handles built into the bed ends also make it easier to move the bed. [02] 7
8 [a] [c] [d] [b]
9 Easier breathing THE PRIORITY OF THE ICU AND ACUTE CARE is to support vitally important functions respiration and heart activity. The Multicare LE bed facilitates their monitoring, contributes to easier respiration and supports the prevention of serious health complications affecting the respiration tract. [01] LATERAL TILT TO PREVENT PULMONARY COMPLICATIONS One of the important tasks of the ICU is the prevention of VAP (Ventilator Associated Pneumonia). The lateral tilt plays a particularly important role in this prevention. The right to left tilt results in the migration of fl uids from the more remote areas of the lungs to places where they can be removed by suction. [02] 30 HEAD OF BED The Multiboard central control panel located at the head end clearly indicates the setting of the backrest to 30 the clinically recommended position for the prevention of respiratory complications. This position can be set with one button on this panel. ORTHOPNEIC CHAIR [a] Sitting up position [b] Supported feet [c] Supported arms [d] Reduced pressure in the abdominal area The orthopneic chair position is designed mainly for patients with resting dyspnea. It combines a high Fowler s position (lungs are in the vertical position), reducing pressure on the internal organs for easier diaphragmatic breathing and allowing better use of additional breathing muscles. [01] [02] 9
10
11 Complex prevention of pressure ulcers Pressure ulcers are a complication that can be avoided. Careful positioning of the patient, reduction of pressure on the soft tissues and restriction of shear forces in changes in the bed s position are key aspects that the Multicare LE bed provides for prevention of pressure ulcers. [01] ERGOFRAME The Multicare LE mattress platform is equipped with the Ergoframe system which respects the natural movement of the human body during positioning and acts as prevention against pressure ulcers in the pelvic and sacral area. The Ergoframe extends the space in the parts at risk (the pelvic and sacral area) when the bed is positioned and signifi cantly reduces the pressure on the skin in this zone. Up to 40% of pressure ulcers appear in the pelvic and sacral area. Another major cause of pressure ulcers is the excessive friction between the mattress and the skin, and the stretching of the patient s skin on the back, especially the shoulder blades. The Ergoframe signifi cantly reduces these shear forces between the mattress and the skin. [02] LATERAL TILT Preventive regular positioning is the basic method of prevention. The lateral tilt turns the patient on his/her side with minimum physical effort. This function signifi cantly facilitates positioning and extends the range of positioning procedures. OPEN MATTRESS COMBINATION ARCHITECTURE The Multicare LE bed concept allows the use of a suitable anti-decubitus system based on the current condition and prognosis of a specifi c patient. The Virtuoso active mattress with its alternating pressure is designed for high risk patients. It works on the principle of alternating pressure in air cells. The pressure falls to zero in one of the three neighbouring cells in a 7.5 minute cycle. Equal pressure distribution Ergomatt foam mattresses or constant low pressure Symbioso 100 mattresses offer preventive anti-decubitus effects. All these systems are fully compatible with the Multicare LE bed and can be alternated randomly as required. [01] [02] 11
12 Support of patient mobilisation Effective cost management THE IMMOBILITY OF PATIENTS causes a number of secondary complications and is an obstacle for speedy convalescence. The integrated system of functions of the Multicare LE bed facilitates the mobility of patients and provides safe area for mobilisation. The Multicare LE bed provides maximum functionality in nursing practice, but also helps to make patient care costs more effective and reduces additional service and maintenance investments. [01] MOBI-LIFT HANDLE The Mobi-lift ergonomic mobilisation handles form part of the bed s mattress platform and provides stable support for the patient when leaving or sitting in the bed. There is a button integrated into the handle which the patient can use to set the bed at the suitable height. [03] INTELLIGENT BED The brain of the Multicare bed is an inner electronic system controlled by several microprocessors. It guards the safety of bed operations, activates automatic systems and ensures wireless communication with the LINIS information system. MOBILISATION HAND-GRIPS IN THE SIDERAILS The hand-grips integrated into the siderails help to actively involve the patient in the process of leaving the bed. [01] [03] LINIS The bed can communicate with other electronic systems. It transfers clinical, working and service data to the LINIS information system for further assessment. This way it is possible to observe selected therapeutic functions and perform remote service diagnostics. This allows quick service repairs at the customer s site without the bed having to be taken away. [02] MOBILISATION POSITION The optimum position for leaving the bed can be set by the press of one button on the control panel. This sets the bed s height so the patient s feet can reach the fl oor and the raised backrest provides him with the necessary support. Multicare Bed PC Statistics Alarm [04] QUALITY OF WORKMANSHIP AND ACCESSIBLE SERVICE Quality components, strict audits and internal inspections guarantee 100% quality of each manufactured bed during production. In view of the international network of its own branches and partnerships fi rms, LINET has service centres to cover all the products it supplies on a global scale. Service [02] [04] 12 13
13 Infection control Up to 30% of hospital infections can be avoided by suitable prevention. The construction and materials used to manufacture the Multicare LE bed allow easy and effective maintenance of all exposed surfaces. [05] COLUMN CONSTRUCTION The columns consist of smooth aluminium sections and the surface is treated so as little dirt as possible sticks to it. The sealing in the supporting columns prevents liquids from leaking inside the column and electric motor. The construction allows unlimited access to all parts of the bed. [05] [06] JOINT-FREE TECHNOLOGY The smooth surfaces of the bed are free of joints enabling quick decontamination and easy maintenance. The number of small parts in the bed s construction is minimised. The controls are located beyond the reach of patients therefore reducing the risk of their contamination. [06]
14 Innovation for greater effi ciency The bed s integrated function makes the work of hospital staff easier, increases the safety and efficiency of the work. The simple controls and maintenance enhances the efficiency of the nursing profession. [01] INTEGRATED SCALES The advanced weighing system integrated into the Multicare LE bed is capable of calculating the exact weight of the patient in all bed positions. This yields not just the current value of the patient s weight, but also displays the changes in the weight over time. The system contains the freeze function, enabling addition or removal of equipment from the bed (infusions, transport monitor) without any effect on the measurement of the patient s weight. [01] X-RAY IN THE BED The side X-ray cassette holder in the backrest allows safe imaging of the chest without having to move the patient in the bed. It is equipped with a cassette location system for precise location under the patient and allows imaging in portrait and landscape format. [02] C-ARM COMPATIBILITY The radiolucent mattress platform makes it possible to examine the patient using a C-arm from the pelvic and sacral area to the head. It makes it possible to perform invasive cardiologic procedures and examinations directly in the bed. [02]
15 Bed description [01] [01] MULTIBOARD is the main control element of the bed used to control all the bed functions. [02] [02] ERGOFRAME MATTRESS PLATFORM works preventively against the development of pressure ulcers and in the orthopneic position to facilitate breathing. [03] [11] [12] [08] FOOT CONTROLS For setting the height and lateral tilt of the bed. [09] I-BRAKE system of automatic braking of the bed. [03] INTEGRATED PATIENT CONTROL accessible in both the lying and sitting position. [05] [04] [10] SIDE HOLDER of small accessories. [04] BED FOOT-END can be adjusted by the electric motor allowing alteration of the bed s length. [06] [10] [11] MANUAL CPR POSITION ADJUSTMENT CONTROL for adjusting the backrest of the mattress platform. [05] NURSE ACP CONTROL PANEL this is an additional control element which can be moved to any position around the perimeter of the bed. [07] [08] [09] [12] SIDERAIL CONTROL with an integrated angle-meter. [06] MOBI-LIFT HANDLE designed for patient mobilisation. [07] ANCHOR POINTS for Segufi x patient restraints. TECHNICAL PARAMETERS ELECTRIC PARAMETERS CERTIFICATES LINET is certifi ed according to the European standards and quality system: EN ISO 9001:2000, EN ISO 13485:2003. Products are manufactured according to the European standards for healthcare and hospital beds: EN , EN , EN , EN , EN ISO 14971, 93/42/EEC, 90/384/EEC. External dimensions (shortest mattress platform position) cm External dimensions (longest mattress platform position) cm Mattress dimensions cm Max. mattress height 23 cm Height adjustment cm Lateral tilt ± 30 TR/ATR tilt 13 /16 Weight (basic equipment) 210 kg Safe working load 250 kg Power supply Maximum input Cover against water and dust Level of protection against electrical current Level of protection against injury from electrical current Electric motor operation mode (load factor) 230 V, ±10 %, Hz 1,6 A, 370 VA IP X4 Class I Applied part type B 10%, max. 2 min/18 min 14 15
16 Multicare LE Bed for critical care and ICU Želevčice 5, Slaný, Czech Republic tel.: , fax: , /
Healthcare Product PORTFOLIO
Lateral tilt Automatic lateral therapy Integrated patient weighing system Bed X-raying Complex pressure ulcer prevention Intelligent siderail concept Quick and comfortable transport Top positioning ergonomics
More informationMINUET 2 COMMUNITY BED RANGE
MINUET 2 COMMUNITY BED RANGE with people in mind PRO-CONTOUR ADVANCE PROFILING A B Pivot points 2 Movements unique to Minuet 2 beds Conventional Bed Minuet 2 Compared to a conventional profiling bed (A),
More informationUniversal medical bed platform
Universal medical bed platform Designed for Value, for Choice, for Life. Focused on meeting customer needs common to all healthcare environments. Standardisation of key components. Low acuity to high dependency
More informationUSER MANUAL. Advanta Bed. From Hill-Rom. Product No. P1600
USER MANUAL Advanta Bed From Hill-Rom Product No. P1600 2002 by Hill-Rom Services, Inc. ALL RIGHTS RESERVED. No part of this text shall be reproduced or transmitted in any form or by any means, electronic
More informationArjoHuntleigh Universal Medical Bed Platform
ArjoHuntleigh Universal Medical Bed Platform Designed for Value, for Choice, for Life. We believe a good hospital bed should: Clinical Focus Provide clinical benefits for patients Be easy and intuitive
More informationSicuro pesa. intensive care. The basis of. Clinic Care Homecare Assist
Sicuro pesa Clinic Care Homecare Assist The basis of intensive care 1. The basis of intensive care Hospital beds are an important part of the medical equipment in an intensive care unit and have a demanding
More informationENTERPRISE 8000 E8X RANGE
ENTERPRISE 8000 E8X RANGE with people in mind DESIGNED FOR YOU AND YOUR PATIENT The new Enterprise 8000 hospital bed from ArjoHuntleigh delivers significant benefits to the patient, caregiver and healthcare
More informationStryker S3 Safe. Simple. Secure.
Medical Stryker S3 Safe. Simple. Secure. Stryker S3 Med/Surg Bed Stryker S3 The standard of care preferred by more hospitals than any other. Retractable Frame Exclusive retractable frame allows proximal
More informationKS-70. Catheterization Table GENERAL
PD505-009A Catheterization Table KS-70 GENERAL This Catheterization Table KS-70, which is combined with X-ray high voltage generator, X-ray tube assembly, X-ray image system (Image Intensifier, Flat Panel
More informationA Simple Guide to Health Risk Assessment Office Environment Series OE 5/2003
A Simple Guide to Health Risk Assessment Office Environment Series OE 5/2003 Occupational Safety and Health Branch Labour Department Occupational Safety and Health Council Contents Introduction 1 Office
More informationCompella Bariatric Bed Advancing bariatric care.
Compella Bariatric Bed Advancing bariatric care. Compella Bariatric Bed Overcoming barriers to efficient, safe and dignified bariatric care. Impact of obesity on health care providers: More than 34% of
More informationSpinal Cord Injury Education. An Overview for Patients, Families, and Caregivers
Spinal Cord Injury Education An Overview for Patients, Families, and Caregivers Spinal Cord Anatomy A major component of the Central Nervous System (CNS) It is 15 to 16 inches long, and weighs 1 to 2 ounces
More informationPatient handling techniques to prevent MSDs in health care
28 Introduction Patient handling techniques Work-related musculoskeletal disorders (MSDs) are a serious problem among hospital personnel, and in particular the nursing staff. Of primary concern are back
More informationVersaCare Bed. Quick Reference Guide
VersaCare Bed Quick Reference Guide Bed Features Item Description Page A Emergency CPR and Emergency 3 Trendelenburg a Control B Battery Back-Up 4 C Foot Controls 4 D Point-of-Care Caregiver Control Panel
More informationTECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
More informationDual Cushion User Manual. Specialist Suppliers to the Healthcare Industry
Dual Cushion User Manual Specialist Suppliers to the Healthcare Industry Thank you for purchasing this Shelden Healthcare pressure relieving cushion system. PLEASE READ THIS USER MANUAL CAREFULLY BEFORE
More informationMaxi sky 600. with people in mind
Maxi sky 600 The complete, customised ceiling lift system with people in mind 2 Maxi Sky 600 A TOTAL CEILING LIFT CONCEPT Maxi Sky 600 is a ceiling lift system that enables patients and residents to be
More informationNIMBUS range advanced MattreSS
NIMBUS range advanced MattreSS replacement SySteMS with people in mind OPTIMUM PRESSURE RELIEF AND COMFORT In clinical use for more than 20 years, Nimbus alternating Mattress replacement Systems have consistently
More informationALENTI. with people in mind
ALENTI The comfortable lift hygiene chair with people in mind 2 Alenti Safety and comfort Alenti is an integral part of a safe, comfortable bathing cycle. This lift hygiene chair from ArjoHuntleigh gives
More informationPROdUcT specifications Pump Mattress Replacement ALPHA REsPONsE PREssURE REdIsTRIbUTION system Mattress Overlay seat cushion GETINGE GROUP
ALPHA RESPONSE Pressure Redistribution System with people in mind INTRODUCTION For over 20 years the Alpha range of pressure redistributing mattresses has been proven to offer patients, carers and healthcare
More informationVENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE
VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE Critical Care SERVO-s 3 SERVO-s SIMPLY MAKES SENSE MAQUET THE GOLD STANDARD Leading the way: MAQUET is a premier international provider of medical products
More informationOxygenation. Chapter 21. Anatomy and Physiology of Breathing. Anatomy and Physiology of Breathing*
Oxygenation Chapter 21 Anatomy and Physiology of Breathing Inspiration ~ breathing in Expiration ~ breathing out Ventilation ~ Movement of air in & out of the lungs Respiration ~ exchange of O2 & carbon
More informationMobile, Powered Positioning Multi-Purpose. Stretcher-Chairs. A Universal Care Platform TMM4 Series
Mobile, Powered Positioning Multi-Purpose Stretcher-Chairs A Universal Care Platform TMM4 Series Mobile, Powered Positioning Multi-Purpose Stretcher-Chairs Standard Features 500 LB PATIENT WEIGHT CAPACITY
More informationSTANDARD OPERATING PROCEDURES (SOP) FOR COMPUTER WORK, DESK TOP
STANDARD OPERATING PROCEDURES (SOP) FOR COMPUTER WORK, DESK TOP General Guidelines-Best Practices: The following guidelines are applicable to office workers who sit at a desk and/or work on computers.
More informationMaxi Sky 2 Plus The complete ceiling lift system
Maxi Sky 2 Plus The complete ceiling lift system A twin cassette ceiling lift system for patients up to 454 kg/1000 lbs with people in mind A versatile ceiling lift system for bariatric patients and the
More informationACTIVE SEATING FOR PEOPLE WITH A KYPHOTIC SPINE. - backrest cushion for the kyphotic spine
ACTIVE SEATING FOR PEOPLE WITH A KYPHOTIC SPINE - backrest cushion for the kyphotic spine Netti Kyphotic is designed for users who require optimum stabilization of their spinal curvature. The upholstery
More informationChapter 26. Assisting With Oxygen Needs. Elsevier items and derived items 2014, 2010 by Mosby, an imprint of Elsevier Inc. All rights reserved.
Chapter 26 Assisting With Oxygen Needs Oxygen (O 2 ) is a gas. Oxygen It has no taste, odor, or color. It is a basic need required for life. Death occurs within minutes if breathing stops. Brain damage
More informationUSER MANUAL. VersaCare Bed. From Hill-Rom. Product No. P3200 and P3201 USR119 REV 5
USER MANUAL VersaCare Bed From Hill-Rom Product No. P3200 and P3201 USR119 REV 5 2005 by Hill-Rom Services, Inc. ALL RIGHTS RESERVED. Manufactured by: HILL-ROM COMPANY, INC. 1069 STATE ROUTE 46 E BATESVILLE,
More informationInfo. from the nurses of the Medical Service. LOWER BACK PAIN Exercise guide
Info. from the nurses of the Medical Service LOWER BACK PAIN Exercise guide GS/ME 03/2009 EXERCISE GUIDE One of the core messages for people suffering with lower back pain is to REMAIN ACTIVE. This leaflet
More informationUSER MANUAL. TotalCare Bariatric Bed. From Hill-Rom. Product No. P1830A
USER MANUAL TotalCare Bariatric Bed From Hill-Rom Product No. P1830A Table of Contents Symbol Definition.................................................................1 Intended Use.....................................................................2
More informationwww.slk-gmbh.de medical solutions ALTERNATING PRESSURE SYSTEMS FOR DECUBITUS PROPHYLAXIS AND THERAPY
www.slk-gmbh.de ALTERNATING PRESSURE SYSTEMS FOR DECUBITUS PROPHYLAXIS AND THERAPY medical solutions www.slk-gmbh.de ALTERNATING PRESSURE SYSTEM FOR DECUBITUS PROPHYLAXIS AND THERAPY Our Company The SLK
More informationTransferring Safety: Prevent Back Injuries
Transferring Safety: Prevent Back Injuries OBJECTIVES: At the end of this class you will be able to: 1. Describe the back and what it does. 2. List things that you can do everyday in your home and at work
More informationBasic Training Exercise Book
Basic Training Exercise Book Basic Training Exercise Book Instructions The exercises are designed to challenge the major muscles groups every day, approximately every 2 to 3 hours., for a total of 6 times
More informationWorking together to prevent pressure ulcers (prevention and pressure-relieving devices)
Working together to prevent pressure ulcers (prevention and pressure-relieving devices) Understanding NICE guidance information for people at risk of pressure ulcers, their carers, and the public Draft
More informationWe at Kosmochem Home Healthcare focus on providing the range of Health, Fitness and Wellness Wll products for personal and professional use.
Mumbai (South ) - Pune We at Kosmochem Home Healthcare focus on providing the range of Health, Fitness and Wellness Wll products for personal and professional use. We offer anti-decubitus systems which
More informationSection 14. Forklift Safety Contents 14.1 Operator Safety
Section 14. Forklift Safety Contents 14.1 Operator Safety... 14-1 14.2 Inspection and Maintenance... 14-2 14.3 Handling the Load... 14-3 14.4 Fueling Liquefied Petroleum (LP) Gas Forklifts... 14-3 14.5
More informationŠKODA MACHINE TOOL HORIZONTAL MILLING AND BORING MACHINES ŠKODA HCW
ŠKODA MACHINE TOOL HORIZONTAL MILLING AND BORING MACHINES ŠKODA HCW KODA HCW TRADITION AND EXPERIENCE The ŠKODA machine tools of different types and design have been present in the world market since the
More informationActive Pressure Relieving Systems
Active Pressure Relieving Systems Phase III The easy access, simple to use CPR facility tag allows rapid deflation of the mattress within 10 seconds. The Phase III mattress incorporates high frequency
More informationExcellent ergonomics.
CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS HUGO THE SMART STOOL FOR YOUR DENTAL PRACTICE Excellent ergonomics. T h e D e n t a l C o m p a n y HUGO INNOVATIVE DESIGN
More informationSystematic X-ray diagnostics as flexible and individual as your dental practice.
CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS XIOS PLUS THE INTRAORAL SENSOR SYSTEM Systematic X-ray diagnostics as flexible and individual as your dental practice. T h
More informationProper Workstation Setup
Proper Workstation Setup A Step by Step Guide to help you organize your workstation and reduce the risk of injury Step 1 Review Work Habits Working in a stationary position for long periods will increase
More informationGuidance for Manual Handling of Gas Cylinder
Guidance for Manual Handling of Gas Cylinder The Manual Handling Operations Regulations 1992 (updated 1998) came into force in January 1993. The purpose of the regulations is to reduce the risk of injury
More informationHigh Impact Intervention Care bundle to reduce ventilation-association pneumonia
High Impact Intervention Care bundle to reduce ventilation-association pneumonia Aim To reduce the incidence of ventilation-associated pneumonia (VAP). Context The aim of the care bundle, as set out in
More informationOperations Manual Blast Chiller
Operations Manual Blast Chiller ADE- 2039-A Page 1 of 14 Contents Page 1 What is the Adande System 3 2 Adande Technology Explained 3 3 EC Declaration of Conformity 4 4 Storage of Product 5 5 Operating
More informationBest Practice Guide 2007. Vehicle Ergonomics Best Practice Guide
Best Practice Guide 2007 Vehicle Ergonomics Best Practice Guide Introduction About 80% of us will experience back pain at some stage in our lives. A number of work and leisure activities can contribute
More informationBARIMAXX II THERAPY SYSTEM. with people in mind. www.arjohuntleigh.com
BARIMAXX II THERAPY SYSTEM with people in mind www.arjohuntleigh.com THE RIGHT FIT FOR YOUR MED-SURG BARIATRIC PATIENTS THE CHALLENGES OF BARIATRIC CARE: FINDING THE RIGHT FIT FOR HANDLING BARIATRIC PATIENTS
More informationElectric profiling beds
Electric profiling beds in health care The wrong bed will waste scarce human resources and put them at risk Rabbi Julia Neuberger, former CE,The King s Fund. 1 A bed is the one piece of equipment nearly
More informationStandard Operating Procedure for Handling an Inanimate Load
Standard Operating Procedure for Handling an Inanimate Load Moving and handling an inanimate load/s is a key part of the working day for most employees. Moving inanimate loads can take place in many different
More informationBasic techniques of pulmonary physical therapy (I) 100/04/24
Basic techniques of pulmonary physical therapy (I) 100/04/24 Evaluation of breathing function Chart review History Chest X ray Blood test Observation/palpation Chest mobility Shape of chest wall Accessory
More informationUrinary Diversion: Ileovesicostomy/Ileal Loop/Colon Loop
Urinary Diversion: Ileovesicostomy/Ileal Loop/Colon Loop Why do I need this surgery? A urinary diversion is a surgical procedure that is performed to allow urine to safely pass from the kidneys into a
More informationReviews of the latest healthcare furniture HEALTHCARE FURNITURE REVIEW
Reviews of the latest healthcare furniture HEALTHCARE FURNITURE REVIEW 5 reasons to choose Healthcare 10 YEAR WARRANTY 10 Year warranty Sebel warrants that all our products will be free from defects for
More informationRESTWELL RISE & RECLINE ARMCHAIRS BORG - OWNER S HANDBOOK PARTS DESCRIPTION
RESTWELL RISE & RECLINE ARMCHAIRS BORG - OWNER S HANDBOOK CONTENTS 1. Introduction 2. Model Description 3. Parts Description 4. Personal Safety 5. Installation Instructions 6. Backrest Removal 7. Operating
More informationMEDICAL SYSTEMS. Monnal T60. Touch and Breathe. www.airliquidemedicalsystems.com
MEDICAL SYSTEMS Monnal T60 Touch and Breathe www.airliquidemedicalsystems.com Close to the emergency Monnal T60 has been designed for mobile medical intervention in all intensive care environments, both
More informationEquipment loan arrangements and loan form
Safety and Health Services Equipment loan arrangements and loan form Document control information Published document name: Work-equip-loan-gn Date issued: February 2016 Version: 4.1 Previous review dates:
More informationMistral, wellness in the air. Ovattificio Fortunato s.r.l. the soul of ideas
Mistral, wellness in the air. Ovattificio Fortunato s.r.l. the soul of ideas Ovattificio Fortunato s.r.l. Via dell Industria, n 109 84092 Bellizzi (SA) Italy ph.: (+39) 089 981146 (+39) 089 981646 Fax:
More informationX-Plain Subclavian Inserted Central Catheter (SICC Line) Reference Summary
X-Plain Subclavian Inserted Central Catheter (SICC Line) Reference Summary Introduction A Subclavian Inserted Central Catheter, or subclavian line, is a long thin hollow tube inserted in a vein under the
More informationA small roller with a big effect. The mini roller for massaging, strengthening, stretching and warming up
A small roller with a big effect The mini roller for massaging, strengthening, stretching and warming up Suva Preventative products P. O Box, 6002 Lucerne Enquiries Tel. 041 419 58 51 Orders www.suva.ch/waswo
More informationIC Counterbalanced Lift Trucks H1.6-2.0FTS Fortens / Fortens Advance
STRONG PARTNERS. TOUGH TRUCKS. IC Counterbalanced Lift Trucks H1.6-2.0FTS Fortens / Fortens Advance 1 600 2 000 kg Fortens H1.6FT, H1.8FT, H2.0FTS Specification Data is based on VDI 2198 Equipment and
More informationRotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.
Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.5-15 bar SX Series SX Compact and powerful Today s users expect maximum availability
More informationPASSIVE ANTI-DECUBITUS MATTRESSES
PAIVE ANTI-DECUBITU MATTREE Collection of passive anti- mattresses of PROMA REHA, Ltd. has been designed with maximum regard to prevention of pressure ulcers, patient safety and perfect hygiene. Anti-
More informationGE Healthcare. Lullaby Warmer. Because every baby deserves a high standard of care
GE Healthcare Lullaby Warmer Because every baby deserves a high standard of care A confident choice for infant warming At GE Healthcare, we share your commitment to providing high quality care for all
More informationBODY FAT & HYDRATION % MONITOR SCALE
EVALUATION BODY FAT & HYDRATION % MONITOR SCALE INSTRUCTION MANUAL MODEL 12-1190 ver 7/08 BODY FAT & HYDRATION % MONITOR SCALE Introduction and Precaution: MODEL: 12-1190 1. Congratulations for purchasing
More informationERGONOMICS. Improve your ergonomic intelligence by avoiding these issues: Awkward postures Repetitive tasks Forceful exertions Lifting heavy objects
ERGONOMICS The goal of ergonomics is to reduce your exposure to work hazards. A hazard is defined as a physical factor within your work environment that can harm your body. Ergonomic hazards include working
More informationIMPORTANT INFORMATION - PLEASE READ. Table of Contents. Introduction. General Information
IMPORTANT INFORMATION - PLEASE READ Introduction Congratulations! Welcome to the world of the ELLIPTICAL CROSS TRAINER. The ELLIPTICAL CROSS TRAINER is one of the finest and most comprehensive pieces of
More informationThe height of the backrest can be adjusted with a simple push of a button.
rh activ RH Activ is our entry level chair. That said, it is still packed with ergonomic features and functions. RH Activ is ergonomically designed through and through, as well as being exceptionally flexible
More informationSMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9
CHAPTER TIG welding Introduction pages - & - WELDING POWER SOURCES DC power sources SMARTY 60 POWER page -5 SMARTY 80 / 0 XL page -6 SMARTY TX 50 page -7 AC/DC power sources SMARTY TX 60 Alu page -8 SMARTY
More informationFredriksons conveyor systems handle goods with a width from 20 mm up to 600 mm.
Conveyor Solutions Whatever your logistic needs, we can offer a conveyor solution. Our flexible systems primary and secondary packaging for single and multi packages, can transport your goods from one
More informationATLET ERGO STAND-ON STACKER AJN/ASN ERGONOMIC STAND-ON STACKERS FOR INTERNAL TRANSFERS AND STACKING IN WAREHOUSES, STORES AND PRODUCTION PREMISES
ATLET ERGO STAND-ON STACKER AJN/ASN ERGONOMIC STAND-ON STACKERS FOR INTERNAL TRANSFERS AND STACKING IN WAREHOUSES, STORES AND PRODUCTION PREMISES 2 The Atlet Ergo Stand-On Stacker is the ideal truck solution
More informationATLANTA. Operation Manual & Product Specification Guide
ATLANTA Operation Manual & Product Specification Guide contents 2. Operation manual 4. Product description 6. What is the intended use of the product? 8. Product features 10. Safety instructions 13. User
More informationAgila Ceiling Supply Unit Medical Supply Units
Agila Ceiling Supply Unit Medical Supply Units Featuring a wide range of configurations and options to choose from, the compact and highly ergonomic Dräger Agila family uses a minimum of precious care
More informationBLADE S-MAX Cabinet for Blade Server
Cabinet for Blade Server 1 2 Overview Material specification Corner verticals: 1.5 mm steel End frames: 1.5 mm steel Panel mounts: 2.0 mm steel Panel mount supports: 1.5 mm steel Side panels, door and
More informationa patient s guide Physiotherapy advice and exercises from four weeks after neck dissection surgery
Physiotherapy advice and exercises from four weeks after neck dissection surgery Patient Information Series PI 47 East and North Hertfordshire NHS Trust 2 This leaflet has been produced by professionals,
More informationWhat is Separation of the Abdominal Muscles after Childbirth (also known as Divarication of Rectus Abdominis)?
What is Separation of the Abdominal Muscles after Childbirth (also known as Divarication of Rectus Abdominis)? Following your pregnancy and the birth of your baby your abdominal (tummy) muscles may have
More information@ EXU Technical Data Low Lift Pallet Truck. EXU 16 EXU 16 Li-Ion EXU 18 EXU 18 Li-Ion EXU 20 EXU 20 Li-Ion EXU 22 EXU-H 18 EXU-H 20
@ EXU Technical Data Low Lift Pallet Truck EXU 16 EXU 16 Li-Ion EXU 18 EXU 18 Li-Ion EXU 20 EXU 20 Li-Ion EXU 22 EXU-H 18 EXU-H 20 This specification sheet to VDI Guidelines 2198 only gives the technical
More informationsection 5 machine guarding and lockout
section machine guarding and lockout This section covers ways to physically protect people working in and around machinery. It includes information on: machinery guards lockout systems emergency stop confined
More informationEnjoy a professional massage in the comfort of your own home. Introducing the Real Pro ULTRA Prestige. 3D Massage Elements
Introducing the Real Pro ULTRA Prestige The EPMA73K massage chair is our most intuitive, personal luxury massage experience. It is designed to help you achieve therapeutic muscle relaxation and increased
More informationAll About Your Peripherally Inserted Central Catheter (PICC)
All About Your Peripherally Inserted Central Catheter (PICC) General Information Intravenous (IV) therapy is the delivery of fluid directly into a vein. An intravenous catheter is a hollow tube that is
More informationPneumatic tube systems in hospitals
Pneumatic tube systems in hospitals 58 090 006/2005 Version: 2005 Pneumatic tube systems in hospitals Reduce Cost and improve service 2 Why pneumatic tube systems in hospitals? Solutions for improved operational
More informationFreezers - Ultrafreezers. Platilab & Irilab Series
Freezers - Ultrafreezers Platilab & Irilab Series PLATILAB: top security and performances with reliable temperature control. IRILAB: combining the high reliability of PLATILAB with the possibility to store
More informationMANAGING MANUAL HANDLING A Guide for Managers and Heads of Departments
MANAGING MANUAL HANDLING A Guide for Managers and Heads of Departments HEALTH & SAFETY UNIT SPRING 2006 CONTENTS INTRODUCTION...2 REGULATION...2 WHAT IS MANUAL HANDLING?...2 RESPONSIBILITIES...2 STRATEGY...2
More informationa lift for the future
a lift for the future 2 Development brings opportunities The elderly population is increasing all the time and there are increasing demands for quality, safety and flexibility. We think this is a good
More informationNursing. Management of Spinal Trauma. Content. Objectives. Objectives
7 cervical vertebrae Content 12 thoracic vertebrae Nursing 5 sacral vertebrae Management of Spinal Trauma Kwai Fung Betty Siu Ward Manager O&T Dept TKOH Date : 22nd April 2007 5 lumbar vertebrae 4 coccygeal
More informationGoFit Platinum Power Vibe
GoFit Platinum Power Vibe GFVT011 GoFit Platinum Pty Ltd Phone 1800 446 348 fax 1300 446 348 www.gofit.com.au IMPORTANT PRECAUTIONS When using an electrical appliance, the basic following precautions
More informationOPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES
OPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES 1 TABLE OF CONTENTS POWER SUPPLY... 3 SPECIFICATIONS... 3 MAINATENANCE AND GENERAL CARE........
More informationAtlet Balance Electric Counterbalance trucks ET EF EH 1.25 3 tons
Atlet Balance Electric Counterbalance trucks ET EF EH 1.25 3 tons 3 models. Man and machine as one. Secure your operations from order to delivery with Atlet Balance electric counterbalance trucks The Atlet
More informationMH 3M & 4M. High pressure washers with hot benefits
MH 3M & 4M High pressure washers with hot benefits The EcoPower boiler provides high efficiency and lowest equivalent fuel consumption as certified by EUnited. All key functions placed for optimal ease-of-use.
More informationRISE & RECLINERS FEATURES & SPECIFICATION CHICAGO - STANDARD & PETITE PETITE MODEL NOW AVAILABLE
RISE & RECLINERS CHICAGO - STANDARD & PETITE Distinct lift, rest and recline action. Smooth and quiet operation. Supreme comfort snooze position. Stylish design to suit any decor. Simple to operate two
More informationRKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features
RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,
More informationelearning at Ramsay Online Orientation Program Guide Version 2.0 Please email any elearning questions to rtisupport@ramsayhealth.com.
elearning at Ramsay Online Orientation Program Guide Version 2.0 Please email any elearning questions to rtisupport@ramsayhealth.com.au Table of contents Introduction to elearning... 3 Ergonomics... 3
More informationP R E S E N T S Dr. Mufa T. Ghadiali is skilled in all aspects of General Surgery. His General Surgery Services include: General Surgery Advanced Laparoscopic Surgery Surgical Oncology Gastrointestinal
More informationSKELETON AND JOINTS G.C.S.E. PHYSICAL EDUCATION. Unit 1. Factors Affecting Participation and Performance. G.C.S.E. P.E. Teacher:.
G.C.S.E. PHYSICAL EDUCATION Unit 1 Factors Affecting Participation and Performance SKELETON AND JOINTS Name: G.C.S.E. P.E. Teacher:. By the end of this booklet you should be able to: Understand what the
More informationHUR Rehab Line H E A L T H & F I T N E S S E Q U I P M E N T
H E A L T H & F I T N E S S E Q U I P M E N T HUR Rehab Line HUR naturally different Contents HUR naturally different HUR SmartCard 1 HUR Rehab Line key to rehabilitation 2 SmartCard FCM Rehab Line computerized
More informationA proper warm-up is important before any athletic performance with the goal of preparing the athlete both mentally and physically for exercise and
A proper warm-up is important before any athletic performance with the goal of preparing the athlete both mentally and physically for exercise and competition. A warm-up is designed to prepare an athlete
More informationEquipment Manual. for. Operation of Automatic Polishing Plate Control on the PM5 Precision Lapping & Polishing Machine.
Equipment Manual for Operation of Automatic Polishing Plate Control on the PM5 Precision Lapping & Polishing Machine Ref: BE-01-53-5 PREFACE: PM5 auto-lap/pol MACHINES The PM5 auto-lap/pol features two
More informationBetter Breathing with COPD
Better Breathing with COPD People with Chronic Obstructive Pulmonary Disease (COPD) often benefit from learning different breathing techniques. Pursed Lip Breathing Pursed Lip Breathing (PLB) can be very
More informationKNEE EXERCISE PROGRAM
KNEE PROGRAM INTRODUCT ION Welcome to your knee exercise program. The exercises in the program are designed to improve your knee stability and strength of the muscles around your knee and hip. The strength
More informationMove and position individuals in accordance with their plan of care
Move and position individuals in accordance with their plan of care Page 1 of 21 Level 2 Diploma in Health and Social Care Unit HSC 2028 Tutor Name: Akua Quao Thursday 12 th September 2013 Release Date:
More informationLong Term Tube Feeding. Sunnybrook. A Guide for Patients and Substitute Decision Makers VETERANS & COMMUNITY
Long Term Tube Feeding A Guide for Patients and Substitute Decision Makers Sunnybrook VETERANS & COMMUNITY Sunnybrook VETERANS & COMMUNITY This brochure has been produced by: Sunnybrook Health Sciences
More informationRecommendations to improve the safety of existing lifts
Recommendations to improve the safety of existing lifts Lift & Escalator Industry Association Lift Safety an introduction Lifts are amongst the very few modes of transport available for continuous unsupervised
More informationProject 4.2.1: Heart Rate
Project 4.2.1: Heart Rate Introduction Even before you were born, one of the first things your doctor did when you went for an office visit was listen to your heart. Your heart rate, the number of times
More information