CAD/CAM product catalogue European Price List in 2016 / 2017
|
|
|
- Andrea Newman
- 9 years ago
- Views:
Transcription
1 CAD/CAM product catalogue European Price List in 2016 /
2 Get connected! For even more flexibility. Download now the Zfx library for free! DIRECT SERVER CONNECTION 3shape Software Update with latest Zimmer/Zfx Implant Libraries compatible with Biomet 3i, Camlog, Dentsply Implants, Megagen, Nobel Biocare, Straumann, Zimmer Download now the Zfx implant library for free at: 2
3 Table of contents CAD/CAM Hard- and Software Zfx IntraScan Zfx Shade Zfx Evolution series Zfx CAD Software Upgrades Zfx Inhouse5x wet & dry CAD/CAM materials Zfx Tools at a glance Zfx Zirconium allround Zfx Zirconium effect Zfx Zirconium BionX Zfx Zirconium Multilayer & High Translucent Zfx Color Liquid allround & Zfx art.liners Zfx Cobalt Chromium Zfx Cobalt Chromium Eco Zfx Titanium G Zfx PMMA Zfx PU Accurate Zfx Baltic Denture Zfx Hybrid ceramic Zfx Glass ceramic Zfx Wax Zfx Accessories Zfx Pre-Abutments Construction components Construction components Order form
4 Zfx IntraScan Zfx Shade Optical impressions of the highest quality can be achieved with the Zfx IntraScan intraoral scanner due to innovative technology. Zfx IntraScan is a lightweight handpiece which is connected to a notebook by means of a cable and weighs only 600 grams. The entire scanning technology is incorporated into the handpiece, removing the need for a complex workstation. The intraoral scanner is used to digitally measure the condition of the bite and a 3D model is generated from the results. Both the hard and the soft tissue are modelled. Digital impressions taken with the Zfx IntraScan are used as a basis for the computer-controlled design and manufacture of implant and tooth-supported restorations. It is not necessary to apply scanning powder. Zfx IntraScan & Software package Zfx IntraScan Zfx IntraScan software / open system System package inclusive of DELL laptop PC system Zfx list price (open system) ZFX , Zfx IntraScan software licence fee p.a. ZFX Zfx Start-up training on request Zfx IntraScan matchholders are available in two sizes (4 and 7 mm) and are compatible with implant systems from Zimmer, Camlog, Nobel Biocare, Straumann and many more. 4
5 Zfx Shade enables tooth color to be determined accurately, quickly, easily and completely independently of ambient light. Determining tooth color with the naked eye often presents a considerable challenge for the dentist. A tooth can have an optically different effect depending on the lighting conditions, and it is therefore not always possible to determine the correct color shade for a restoration. The Zfx Shade provides dentists with the perfect assistant for determining tooth color digitally. The patented unit consists of a digital camera and a spectrophotometer with LED lighting. The unit enables spectral data to be evaluated extremely accurately, and the exact tooth color is determined without the effect of ambient light. Zfx Shade package Zfx Shade Zfx Shade Software (3 licences) Zfx list price ZFX , The Zfx Shade detects colors as they really are, independent of lighting conditions quickly, accurately and reliably. 5
6 Zfx Evolution series The Zfx Evolution series is perfectly catered to the individual needs of the dental technician. The Zfx Evolution series embodies a fully automatic stripe light scanner with open interface which has been specially developed by Zfx Innovation in Bolzano, Italy. The scanners can digitalise complete jaw models for con structing complex bridge frameworks with up to 14 links as well as articulated models. With scan speeds of less than 35 seconds for single preps and 70 seconds per model, Zfx provides not only one of the fastest but also one of the most precise CAD systems on the dental market. The Zfx Evolution Scanner is the basic version within the Evolution series of scanners and already incorporates excellent performance features. For those who want more the Zfx Evolution plus + offers further innovative characteristics. The scanner is Ready for 3D-Printing, includes an additional color camera and is compatible with additional tools in the CAD software such as the Texture Mapping module. Zfx Scanner- & Software package Zfx Evolution Basic package 3D-Scanner Zfx Evolution Zfx CAD software / open system PC unit with 22" TFT Display Zfx list price (open system) ZFX , Zfx Evolution plus package 3D-Scanner Zfx Evolution plus Zfx CAD software / open system PC-Einheit mit 22" TFT Display Zfx Manager Zfx Multi-Die Table Zfx Multi-Die Software Upgrade Zfx list price (open system) ZFX , Zfx Evolution plus + package 3D-Scanner Zfx Evolution plus + Zfx CAD software / open system PC unit with 22" TFT Display Zfx Manager Zfx Multi-Die Table Zfx Multi-Die Software Upgrade Color Camera Texture Mapping Zfx list price (open system) ZFX , Zfx CAD software licence fee p.a. ZFX Zfx Start-up training (At your Zfx partner; max. 2 technicians) on request 6
7 Measuring accuracy < 9 µm * Zfx Evolution series components Zfx Multi-Die Table Scan up to 12 dies at once (must be used in combination with the Zfx Multi-Die Software Upgrade, see page 8). Zfx Baltic Denture Holder Scan For the recording of upper and lower jaw in one scan procedure only (more information regarding the Zfx Baltic Denture Sets can be found on page 30). Zfx Multi-Die Table ZFX Zfx Baltic Denture Holder Scan ZFX Zfx Arti-Synchronizer For an exact transfer of the model from the real to the virtual articulator. The module is available for different systems (original split-cast plates necessary). Zfx Evolution plus + Upgrade: Color Camera The Color Camera 2+1 technology offers high resolution and realistic color reproduction. Zfx Arti-Synchronizer (system exclusive base plates) from ARTEX 126 mm hight ZFX from ARTEX 116 mm hight ZFX from SAM ZFX from STRATOS ZFX from KAVO ZFX from PANADENT ZFX Zfx Evolution plus + Upgrade: Color Camera ZFX , * Measurement according to the VDI test procedure 7
8 Zfx CAD-Software Upgrades Upgrade: Zfx Multi-Die Function for scanning up to 12 dies in one scan (includes the necessary software function and appropriate accessories). Zfx Multi-Die ZFX Upgrade: Zfx DICOM Viewer For the visualization and storage of DICOM data (e.g. surgical templates). Zfx DICOM Viewer ZFX Upgrade: Zfx Bite-Splint The Zfx Bite Splint module allows the fast and high-quality construction of therapeutic bite splints. Zfx Bite-Splint ZFX Upgrade: Zfx Virtual Articulator Enables digitalisation and integration of articulated models (articulator systems Artex, Protar, SAM, Stratos and Panadent ) into the software. Zfx Virtual Articulator ZFX , Upgrade: Zfx Abutment Designer Tool for designing custom implant abutments. The associated library includes connector geometries for all common implant systems. Upgrade: Zfx Bar Designer Allows the digital design of all kinds of bars as well as the placement of separation attachments and Locators. Zfx Abutment Designer ZFX , Zfx Bar Designer ZFX , Upgrade: Zfx Provisional Crown & Bridges Enables the fabrication of temporary restorations based on the scan (the anatomy is duplicated). Upgrade: Zfx TruSmile Module for displaying restorations in the software with almost photographic realism. Zfx Provisional Crown & Bridges ZFX Zfx TruSmile ZFX
9 Upgrade: Zfx Digital-intraModel For digital model construction including analog libraries of various implant manufacturers. Zfx Digital-intraModel ZFX , Upgrade: The Art of Shape Enhancement of library including different tooth shapes for individual and aesthetic reconstruction of prothetic restorations. The Art of Shape ZFX Upgrade: Zfx Baltic Denture Software For the digital design and manufacturing of complete acrylic dentures. Zfx Baltic Denture Software ZFX , Upgrade: Tooth library ZRS by Manfred Wiedmann Expansion of the tooth library with 118 designs (Sets for Upper and Lower, anterior and posterior teeth). Tooth library ZRS ZFX NEW Upgrade: Zfx Encode Converter - Software-Module Software-module intended for the decoding of 3D information of BellaTek Encode Gingiva-former from Zimmer Biomet and for the construction of individual Encode Abutments. Zfx Encode Converter - Software Module Zfx Encode Converter - License-Fee p. a. ZFX , ZFX
10 Zfx Inhouse5x wet & dry With the Inhouse5x wet & dry, Zfx offers a compact milling unit suitable for 5-axis simultaneous machining that can be easily integrated into any laboratory. The machine is equipped with a high-frequency spindle (6,000 to 100,000 rpm). Thus, together with a variety of milling strategies and tools, a faster and more economically efficient manufacturing process is guaranteed. The Zfx Inhouse5x is suitable already in basic version for milling and grinding, resp. for the dry and wet processing, so various materials such as zirconia, ceramic, composite, PMMA, wax, cobalt chrome and titanium can be processed. Zfx Inhouse5x wet & dry & CAM software package Zfx Inhouse5x - Zfx Inhouse system (open) for simultaneous 5-axis milling in wet and dry mode Lower frame incl. suction and filter Zfx Inhouse5x - CAM software - EXPERT 5-Axis simultaneous PC DELL Precision T1700 CAD-Monitor DELL Professional P cm (22") Zfx blank holder r2d2 Zfx Single-Block Holder for Sirona CEREC climbing system Zfx Cutting Oil Zfx list price (open system) ZFX , Installation and 3 days Zfx start-up local training (daily rate, ex works) ZFX , Zfx CAM software licence fee p.a. ZFX , Zfx Inhouse5x Filter Coolant filter 100 µm for Zfx Inhouse5x ZFX Suction filter for Zfx Inhouse5x ZFX Swarf filter 45ppi for Zfx Inhouse5x ZFX
11 Zfx Inhouse5x components + options Zfx Blankholder Fixture for holding raw materials that are provided as blanks. (The Blankholder is included in the Zfx Inhouse5x wet & dry & CAM-Software Package). Zfx Single Blockholder Fixture for single blocks (such as: IPS e.max, VITA Suprinity, IPS Empress ). Zfx Blankholder ZFX , Zfx Single Blockholder ZFX Zfx Multi-Block Support (up to 15 blocks) Allows the positioning and management of different blocks (e.g.: IPS e.max, VITA Suprinity, IPS Empress ). Zfx Baltic Denture Holder Mill Tool holder for the recording of Zfx Baltic Denture Blanks for the manufacturing of full dentures. NEW Zfx Multi-Block Support ZFX , Zfx Baltic Denture Holder Mill ZFX Zfx Pre-Abutment Multi-Blank Holder Tool holder for the placement of the Zfx Pre-Abutment Blanks with different geometries available to suit common implant manufacturers. Zfx Upgrade: Multi-Unit Processing Enables the multi-unit production for cobalt chrome, titanium, zirconium and PMMA. Zfx Pre-Abutment Multi-Blank Holder ZFX , Zfx Multi-Unit Software CAM Upgrade ZFX , Option: Multiple CAM session Enables opening and computation of various CAM sessions at the same time. Option: Multi machine CAM Enables direct control of several machines. Option: Multiple CAM session ZFX Option: Multi machine CAM ZFX
12 Zfx Tools at a glance Zfx Tools For the precise processing of dental materials, Zfx offers VHM milling tools that have been improved through years of experience involving over restorations. Various cutting geometries and surfaces have been developed and produced. These improvements provide the highest quality and enhance key elements including: the tool life, tool cost and processing time, thus guarantee efficiency. Direct feedback from production ensures short development cycles and enables quick response times. The Zfx milling tools assortment covers a wide range of applications and material options. Zfx Zirconium Tools VHM milling tools with the latest generation diamond coating ensure the excellent edge stability and running performance in wet and dry processing. Tool ID 0 Milling tool 0 Shaft Tool length Cutting depth T mm 4 mm 25 mm 20 mm ZFX T mm 4 mm 25 mm 15 mm ZFX T mm 4 mm 25 mm 10 mm ZFX T mm 4 mm 25 mm 6 mm ZFX Zfx Cobalt Chromium Tools VHM milling tools with special coatings and cutting geometries are available for all production steps from rough cutting to fine finishing of the margin. The tools are suitable for wet and dry milling. Tool ID 0 Milling tool 0 Shaft Tool length Cutting depth T mm 4 mm 25 mm 11.5 mm ZFX T mm 4 mm 25 mm 6 mm ZFX T mm 4 mm 25 mm 6 mm ZFX T mm 4 mm 25 mm 1.5 mm ZFX T mm 4 mm 25 mm 12 mm ZFX T mm 4 mm 25 mm 8 mm ZFX T mm 4 mm 25 mm 4 mm ZFX
13 Zfx Titanium and Pre-Abutment Tools VHM milling tools with special coatings for safe and efficient milling of titanium. Tool ID 0 Milling tool 0 Shaft Tool length Cutting depth T mm 4 mm 25 mm 11.5 mm ZFX T mm 4 mm 25 mm 6 mm ZFX T mm 4 mm 25 mm 6 mm ZFX T mm 4 mm 25 mm 1.5 mm ZFX T mm 4 mm 25 mm 8 mm ZFX T mm 4 mm 25 mm 4 mm ZFX T mm 4 mm 25 mm 12 mm ZFX Zfx PMMA, Wax and Baltic Denture Tools Special cutting geometries for high-performance milling of all common plastic dental materials. Tool ID 0 Milling tool 0 Shaft Tool length Cutting depth T mm 4 mm 25 mm 15 mm ZFX T mm 4 mm 25 mm 8 mm ZFX T mm 4 mm 25 mm 6 mm ZFX T mm 4 mm 25 mm 6 mm ZFX Zfx PU Accurate Tools Special cutting geometries for high-performance milling of all common plastic dental materials. Tool ID 0 Milling tool 0 Shaft Tool length Cutting depth T mm 4 mm 27 mm 16 mm ZFX T mm 4 mm 25 mm 15 mm ZFX Zfx Glass- and Hybrid ceramic Tools Diamond coated tools are available in various grain sizes for rough to fine finish. Tool ID 0 Milling tool 0 Shaft Tool length Cutting depth T mm 4 mm 25 mm 12 mm ZFX T mm 4 mm 25 mm 10 mm ZFX T mm 4 mm 25 mm 10 mm ZFX
14 Zfx Zirconium allround Zfx Zirconium effect Zfx Zirconium allround The pre-sintered Zfx Zirconium allround, consists of a homogeneous microstructure features an extremely high tensile strength during processing, excellent edge stability and long-term hydrothermal resistance. The material is highly biocompatible and avoids the unpleasant taste of metal and hot/cold conductivity. This zirconium is suitable for crowns, bridges, inlays, onlays, bars, implant bridges and attachments. Physical properties Density (after sintering operation) g/cm 3 > 6.0 E-module GPa > 200 CTE ( C) 10-6 K -1 CTE 10.5 Crack toughness MPa*m 1/2 > 9 Bending strength MPa 1,200 (± 200) Open porosity % 0 ø 98.5 ø 94 Chemical composition Zirconium oxide ZrO % Yttrium oxide Y 2O % Hafnium oxide HfO % Aluminium oxide Al 2O % Zfx Zirconium allround Blanks Dimension Color 98 x 10 mm 0.00 ZFX x 12 mm 0.00 ZFX x 14 mm 0.00 ZFX x 16 mm 0.00 ZFX Dimension Color 98 x 18 mm 0.00 ZFX x 20 mm 0.00 ZFX x 25 mm 0.00 ZFX
15 Zfx Zirconium effect Zfx Zirconium effect combines the material properties of Zfx Zirconium allround with a significant increase in translucency. The material has a high esthetic value while providing all the benefits of zirconium dioxide. Indications include crowns, bridges, inlays and onlays. Physical properties Density (after sintering operation) g/cm 3 > 6.0 E-module GPa > 200 CTE ( C) 10-6 K -1 CTE 10.5 Crack toughness MPa*m 1/2 > 6 Bending strength MPa 1,200 (± 200) Open porosity % 0 ø 98.5 ø 94 Chemical composition Zirconium oxide ZrO % Yttrium oxide Y 2O % Hafnium oxide HfO % Aluminium oxide Al 2O % Zfx Zirconium effect Blanks Dimension 98 x 10 mm ZFX x 12 mm ZFX x 14 mm ZFX x 16 mm ZFX Dimension 98 x 18 mm ZFX x 20 mm ZFX x 25 mm ZFX Zfx Zirconium Tools (Detailed information can be found on page 12 and 13.) Tool ID 0 Milling tool (mm) 0 Shaft (mm) Tool length (mm) Cutting depth (mm) T ZFX T ZFX T ZFX T ZFX
16 Zfx Zirconium BionXX 2 Zfx Zirconium BionX 2 The new Zfx BionX² is a translucent, stable zirconium oxide that sets new material standards. Due to the cubic-tetragonal mixed microstructure, a light transmission that has not been achieved up to now, is combinded with excellent mechanical properties. The result is a biocompatible, high-performance ceramic (type II, class 5) for full-contour inlays, onlays, veneers and up to three-unit bridges. Physical properties Density (after sintering operation) g/cm 3 > 6.0 E-module GPa > 210 CTE ( C) 10-6 K -1 CTE 10 Crack toughness MPa*m 1/2 > 4.8 Bending strength MPa > 720 ø 98.5 ø 94 Chemical composition Zirconium oxide ZrO % Yttrium oxide Y 2O % Hafnium oxide HfO % Aluminium oxide Al 2O % Zfx Zirconium BionX 2 Blanks Dimension 98 x 10 mm ZFX x 12 mm ZFX x 14 mm ZFX x 16 mm ZFX Dimension 98 x 18 mm ZFX x 20 mm ZFX x 25 mm ZFX
17 NEU Zfx BionX 2 Zfx Zirconium Tools (Detailed information can be found on page 12 and 13.) Tool ID 0 Milling tool (mm) 0 Shaft (mm) Tool length (mm) Cutting depth (mm) T ZFX T ZFX T ZFX T ZFX The Art of Shape Three modules for Aesthetics Simply clever: Zfx Dental introduces The Art of Shape a superior product line for the fabrication of high aesthetic zirconia restorations. The Art of Shape is the perfect solution to economically produce highly aesthetic restorations, allowing you to easily compete against low-end dental prostheses. First, the crowns are custom designed, and, if applicable, reduced for the veneering (cut-back) through assistance of the Zfx tooth libraries. The framework is then milled out of a Zfx BionX² zirconia blank, coloured with Zfx Color Liquid allround and the Zfx art.liners to achieve a beautiful finished product. Veneers if requested can be completed in only a few steps, normally requiring only one firing. 17
18 Zfx Zirconium Multilayer & High Translucent KATANA Zirconium KATANA Zirconium series have different levels of translucency and mechanical properties according to their application. Select the right series for your application using the following table: Flexural Strength (Three-point bending test) Translucency According to ISO 6872 : 2008, Sample Size: 3 x 4 x 40 mm Wave length of light: 700 nm, Thickness of sample: 0.5 mm (MPa) (%) Recommended and Indicated Application KATANA Zirconium UTML STML HT / ML 3 Anterior Crown Veneer Posterior Crown Inlay / Onlay Anterior 3-unit Bridge Posterior 3-unit 4 units or more Framework Properties Translucency Flexural strength HT (HT10) UTML 1 STML 1 e.max Press LT (A1) 2 HT (HT10) UTML 1 STML 1 e.max Press LT (A1) 2 The number of check marks ( ) indicates the degree to which the material is recommended for the listed application. The bar ( ) means that it is not recommended. 1 Evaluated by base material (white color); 2 Not trademark of Kuraray Co., Ltd. Date source: Kuraray Noritake Dental Inc. 3 KATANA Zirconium HT/Multilayer is a high strength zirconia KATANA Zirconium Multilayer The KATANA blank, consisting of four pre-shaded layers, enables an proficient production of very natural restorations without staining or dipping as the soft cervical, dentin and enamel shades are already intergrated in the blank. Without additional steps, frameworks and full-contour restorations with natural color gradations can be created. The workflow is reduced to a minimum. Error-prone steps are eliminated and the results are reproducible. Translucency of 1.0 mm thickness A light A A dark A B light B ø 98.5 ø KATANA Zirconium Multilayer Blanks Dimension Color / A-Light A-Dark B-Light 98 x 14 mm EU EU EU x 18 mm EU EU EU x 22 mm EU EU EU
19 KATANA Zirconium STML KATANA Zirconium STML (Super Translucent Multi Layered) Blanks are composed of 4 shaded color gradients and are characterized by a high, natural translucency. The material is perfect for the manufacturing of aesthetic restorations such as crowns, bridges, vereers and inlays/onlays. Color NW A1 A2 A3 A3.5 ø 98.5 ø KATANA Zirconium STML Blanks Dimension Color / NW A1 A2 A3 A3,5 98 x 14 mm EU EU EU EU EU x 18 mm EU EU EU EU EU x 22 mm EU EU EU EU EU Zfx Zirconium Tools See spreadsheet on page
20 Zfx Zirconium Multilayer & High Translucent KATANA Zirconium UTML KATANA Zirconium UTML (Ultra Translucent Multi Layered) Blanks are also composed of 4 shaded color gradients. Due to the very high translucency and the natural color gradient the blanks are ideal for aesthetic anterior and posterior restorations, such as veneers and anterior crowns. Moreover the blanks comply with the VITA shade guide (VITA classical A1 - D4 ). Color ENW EA1 EA2 EA3 ø 98.5 ø KATANA Zirconium UTML Blanks Dimension Color / ENW EA1 EA2 EA3 98 x 14 mm EU EU EU EU x 18 mm EU EU EU EU x 22 mm EU EU EU EU
21 KATANA Zirconium HT KATANA Zirconium HT (High Translucent) are white high translucent blanks, that are perfectly suited for the purposes of individual colouring. The high translucency meets all aesthetic requirements. A low monoclinic transformation guarantees excellent durability at a lower temperature. ø 98.5 ø KATANA Zirconium HT Blanks Dimension Color / HT HT12 HT13 98 x 10 mm EU EU EU x 14 mm EU EU EU x 18 mm EU EU EU x 22 mm EU EU EU x 26 mm EU EU EU Zfx Zirconium Tools (Detailed information can be found on page 12 and 13.) Tool ID 0 Milling tool (mm) 0 Shaft (mm) Tool length (mm) Cutting depth (mm) T ZFX T ZFX T ZFX T ZFX
22 Zfx Color Liquid allround Zfx art.liners Zfx Color Liquid allround The Zfx Color Liquids allround for zirconium dioxide provide the ideal basis for the staining full-contour as well as veneered zirconium restorations. To create a successful full-ceramic or veneered all-ceramic restoration, an efficient production process in the lab is critical. Zfx Color Liquids allround offers a staining system that is suitable for all kinds of zirconium. Zfx Liquid allround - Dentin colors according to Vita for dipping and painting techniques Dimension Color 100 ml A1 ZFX ml A2 ZFX ml A3 ZFX ml A3.5 ZFX ml A4 ZFX ml A4+ ZFX ml B1 ZFX ml B2 ZFX ml B3 ZFX ml B4 ZFX ml B4+ ZFX ml C1 ZFX ml C2 ZFX ml C3 ZFX ml C4 ZFX ml C4+ ZFX ml D2 ZFX ml D3 ZFX ml D3+ ZFX ml D4 ZFX ml D4+ ZFX Zfx Liquid allround - incisal colors for occlusal and incisal characterization Dimension Color 30 ml dark pink ZFX ml light pink ZFX ml dark grey ZFX ml light grey ZFX ml dark brown ZFX ml light brown ZFX Zfx Liquid allround - effect colors for tinting of dentin colors or occlusal characterization Dimension Color 15 ml Incisal SA 1 ZFX ml Incisal SA 2 ZFX ml Incisal SC 1 ZFX ml Incisal SC 2 ZFX ml Incisal SO ZFX Zfx Variation Liquid allround for lightening of the dentin shades Dimension 30 ml ZFX ml ZFX
23 Zfx Color Liquid allround - Set The Zfx Color Liquid allround - Set includes all relevant liquids for the production of aesthetic full-contour zirconia restorations. The dentin colors are also suitable for staining veneered crowns and frameworks. Delivery contents Set 16 bottles (30 ml) dentin colors 5 bottles (15 ml) incisal colors 40 brushes for dipping Liquid Set ZFX Zfx art.liners The Zfx art.liners, a set consisting of 5 different brushes, are perfectly suitable for the manufacturing of fully anatomical zirconium works. Each brush-tip is intended for a certain purpose from the painting of the unsintered zirconium to the application of the glazing material on the finished work. The brush handle is ergonomically formed and fits perfectly into the hand. The triangular shape is the basis for the no.roll system, a roll off from the table is prevented. Delivery contents Set color.liner: Coloring brush for the application of finest color portions (Brush size: -10) glasur.liner: Glasur brush for the application of finest glasur portions (Brush size: 1) +color.liner: Color brush for the application of coloring big zirconia bridges (Brush size: 6) individual.liner: Individual brush for the application before and after sintering (Brush size: 4) gingiva.liner: Gingiva brush for the application coloring gingiva before sintering (Brush size: 8) with innovative no.roll system Art. No. Price ( ) art.liners ZFX
24 Zfx Cobalt Chromium Zfx Cobalt Chromium Eco Zfx Cobalt Chromium Zfx Cobalt Chromium is a beryllium-nickel-free non-precious alloy made from cobalt chromium. The material is suitable for the production of crowns and bridges, one-piece abutments and implant supported supra-structures. Characterized by its reduced hardness, the CoCr blank is well-suited for milling and ceramic veneering. Physical properties Density g/cm Hardness HV 10/ E-module GPa 240 CTE ( C) 10-6 K -1 CTE 14.5 Yield Strength MPa 375 Tensile strength MPa 525 Percentage elongation % 14.7 ø 98.5 ø Chemical composition Cobalt Co % Chrom Cr % Silicon Si 0-2 % Zfx Cobalt Chromium Blanks Dimension 98 x 10 mm ZFX x 12 mm ZFX x 13.5 mm ZFX x 15 mm ZFX Dimension 98 x 18 mm ZFX x 20 mm ZFX x 24.5 mm ZFX
25 Zfx Cobalt Chromium Eco NEW With the industrially manufactured Zfx Cobalt Chromium Eco Blanks, Zfx is able to provide a material that offers a cost-effective solution in the production of high-quality dental prosthetics. The material has been specifically optimized for the requirements of the Zfx Inhouse5x and is characterized by excellent milling properties along with limited milling tool wear. The blanks, free of nickel and beryllium, are suitable for single crowns as well as for complex implant restorations or ceramic veneering. Physical properties Density g/cm Hardness HV 5/ E-module GPa 200 CTE ( C) 10-6 K -1 CTE 14.4 Yield Strength MPa 300 Tensile strength MPa 610 Percentage elongation % 5 ø 98.5 ø 94 Chemical composition Cobalt Co % Chrom Cr % Zfx Cobalt Chromium Eco Blanks Dimension 98 x 10 mm ZFX x 12 mm ZFX x 13.5 mm ZFX Dimension 98 x 15 mm ZFX x 18 mm ZFX x 20 mm ZFX Zfx Cobalt Chromium Tools (Detailed information can be found on page 12 and 13.) Tool ID 0 Milling tool (mm) 0 Shaft (mm) Tool length (mm) Cutting depth (mm) T ZFX T ZFX T ZFX T ZFX T ZFX T ZFX T ZFX
26 Zfx Titanium G5 Zfx Titanium G5 The high-quality titanium alloy features consistent quality and provides high fracture and hardness values. Thus, the titanium blank is ideal for the fabrication of crowns and bridges in both anterior and posterior regions for implant and bar reconstructions. All commercially available low-fusing ceramics can be used for veneering. Physical properties Density g/cm Hardness HV 10/ E-module GPa 114 CTE ( C) 10-6 K -1 CTE 10.3 Yield Strength MPa 836 Tensile strength MPa 897 Percentage elongation % 12 Chemical composition Titanium Ti ~ 90 % ø 98.5 ø Ferrum Fe 0.13 % Aluminium Ai 6.0 % Vanadium V 4.1 % Oxygen O 0.1 % Hydrogen H % Nitrogen N 0.01 % Carbon C 0.03 % Zfx Titanium G5 Blanks Dimension 98 x 10 mm ZFX x 12 mm ZFX x 13.5 mm ZFX x 15 mm ZFX x 16 mm ZFX Dimension 98 x 18 mm ZFX x 20 mm ZFX x 22 mm ZFX x 24.5 mm ZFX
27 Zfx Titanium Tools (Detailed information can be found on page 12 and 13.) Tool ID 0 Milling tool (mm) 0 Shaft (mm) Tool length (mm) Cutting depth (mm) T ZFX T ZFX T ZFX T ZFX T ZFX T ZFX T ZFX Zfx Aesthetic Workshops NEW Learn more about the production of aesthetic restorations by attending a Zfx Aesthetic Workshop. Experts share their knowledge in an informative and practical format from designing with the Zfx Model Creator up to milling and staining with Vita Accent Plus Glaze and the Zfx Color Liquid allround. All current dates as well as the complete Zfx training program can be found at 27
28 Zfx PMMA Zfx PU Accurate Zfx PMMA Thermoplastic PMMA, consisting of carbon chains, is characterized by its high fracture and bending strength along with excellent biocompability. The material is extremely color-stable and possesses a high translucency. The dense material microstructure ensures resistance against stain. PMMA is suitable for the fabrication of temporary crowns, bridges, inlays and onlays. The Safety Data Sheets with all physical properties and chemical compositions can be found at ø 98.5 ø Zfx PMMA Blanks Color Dimension Zfx PMMA color A 98.5 x 20 mm ZFX Zfx PMMA color A x 20 mm ZFX Zfx PMMA color B 98.5 x 20 mm ZFX Zfx PMMA color B x 20 mm ZFX Zfx PMMA color B x 20 mm ZFX Zfx PMMA color C 98.5 x 20 mm ZFX Zfx PMMA multicolor A1 - A x 20 mm ZFX Zfx PMMA multicolor A2 - A x 20 mm ZFX Zfx PMMA multicolor A2 - A x 20 mm ZFX Zfx PMMA pink pink 98.5 x 20 mm ZFX ZENOTEC PMMA cast cast 98 x 18 ZFX Zfx PMMA transparent bite transparent bite 98.5 x 20 mm ZFX Zfx PMMA Tools (Detailed information can be found on page 12 and 13.) Tool ID 0 Milling tool (mm) 0 Shaft (mm) Tool length (mm) Cutting depth (mm) T ZFX T ZFX T ZFX T ZFX
29 Zfx PU Accurate The Zfx PU Accurate is charcterized by form stability, breakage resistance and excellent cutting properties. The material is easily and quickly milled. It is suitable for model fabrication using CAD/CAM technology and digital impressions. ø 98.5 ø 94 Physical properties ivory / grey Density g/cm / 1.0 Shore Hardness D 75 / D 76 E-module MPa 1,800 / 1,850 Bending strength MPa 48 / 50 Tensile strength MPa 47 / 48 Impact strength kj/m 2 13 / 14 Heat resistance C 85 / 90 Linear coefficient of thermal expansion K x 10-6 / x Zfx PU Accurate Blanks Dimension Color 98 x 12 mm ivory ZFX x 12 mm grey ZFX x 16 mm ivory ZFX x 16 mm grey ZFX x 20 mm ivory ZFX x 20 mm grey ZFX x 26 mm ivory ZFX x 26 mm grey ZFX Zfx PU Accurate Tools (Detailed information can be found on page 12 and 13.) Tool ID 0 Milling tool (mm) 0 Shaft (mm) Tool length (mm) Cutting depth (mm) T ZFX T ZFX
30 Zfx Baltic Denture Zfx Baltic Denture Zfx Baltic Denture Key Set With the Zfx Baltic Denture System, full dentures of highly crossed linked PMMA can be produced. Within the milling blanks the dental arches are already included in functional and aesthetic positioning. The perfect positioning of the row of teeth is fixed with the help of the Zfx Baltic Denture KEY Set according to functional and aesthetic aspects. Physical properties Residual monomer content % under 1 Bending Strengh MPa > 90 Water Absorption μg/mm 3 > 32 Zfx Baltic Denture Sets Zfx Evolution Baltic Denture Set Zfx Milling Lab Baltic Denture Set Zfx Baltic Denture Key Set consisting of BD KEY (UpperKEY & LowerKEY ), BD KEY Lock, BD KEY Plane, BD KEY Fin, BD KEY Connect Art. No.: ZFX x Art. No.: ZFX Zfx Baltic Denture Holder Scan for the Zfx Evolution 1x 1x Zfx Baltic Denture Software 1x 1x Zfx Baltic Denture Holder Mill for the Zfx Inhouse5x Zfx Baltic Denture Load Starterkit consisting of one upper jaw small, lower jaw small, upper jaw medium, lower jaw medium, upper jaw large, lower jaw large Set Price: 4, Set Price: 6, x 1x 1x 30
31 Zfx Baltic Denture Holder Scan for the Zfx Evolution Zfx Baltic Denture Holder Mill for the Zfx Inhouse5x Zfx Baltic Denture Load Starterkit Zfx Baltic Denture Holder Art-No. Price ( ) Zfx Baltic Denture Holder Scan for the Zfx Evolution ZFX Zfx Baltic Denture Holder Mill for the Zfx Inhouse5x ZFX Zfx Baltic Denture Tools (Detailed information can be found on page 12 and 13.) Tool ID 0 Milling tool (mm) 0 Shaft (mm) Tool length (mm) Cutting depth (mm) T ZFX T ZFX T ZFX T ZFX
32 Zfx Hybrid ceramic Zfx Glass ceramic VITA Enamic VITA ENAMIC is a dental hybrid ceramic with dual network structure. The dominating ceramic network is strengthened by a polymer network, whereby both networks penetrates each other (polymer network ~ 14 weight.-%, ceramic network ~ 86 weight.-%). Hybrid ceramics are characterized by high durability, superior aesthetics and they also possess very tooth-like chracteristics making them ideal for aesthetically crucial restorations in the mouth. The result is highly precise and accurate in every detail. Physical properties Hardness HV 10/ E-module GPa 30 Weibull Module 20 Density g/cm Bending strength MPa Static Breaking Load N 1,766 Crack toughness (SEVNB) MPa*m Percentage elongation % 0.5 Chemical solubility μg/cm Chemical composition Silicon Dioxide SiO % Aluminium oxide Al 2 O % Natrium oxide Na 2 O 9-11 % Potassium Oxide K 2 O 4-6 % Boron Trioxide B 2 O % Titanium Dioxide TiO 2 < 1 % Calcium Oxide CaO < 1 % VITA Enamic Blocks Color Content 0M1-HT 5 pcs. EN1EM M1-HT 5 pcs. EN1EM M2-HT 5 pcs. EN1EM M2-HT 5 pcs. EN1EM M2-HT 5 pcs. EN1EM M2-HT 5 pcs. EN1EM Color Content 0M1-T 5 pcs. XXXX M1-T 5 pcs. XXXX M2-T 5 pcs. XXXX M2-T 5 pcs. XXXX M2-T 5 pcs. XXXX M2-T 5 pcs. XXXX
33 VITA Suprinity VITA SUPRINITY enables due to its fine-grained and homogenous microstructure exact final outcomes and is characterized by a constant high toughness. The integrated translucency, luorescence and opalescence ensure a natural-looking colors and high-aesthetic results. The material is known for its excellent processing properties, such as e.g. the simple manual grinding and polishing properties. Due to the wide spectrum of indications from crowns in the anterior and posterior regions to supra-constructions on implants up to veneers, inlays and onlays the new CAD/CAM ceramic is versatilely applicable. Physical properties Hardness HV 10/30 ~ 7,000 E-module GPa ~ 70 CTE ( C) 10-6 K -1 CTE ~ point bending strength MPa ~ point bending strength pre-crystallised MPa ~ 180 Biaxial strength % ~ 540 Crack toughness (SEVNB) MPa*m ~ 2.0 Transformation temperature C ~ 620 Softening temperature C ~ 800 Chemical solubility μg/cm 2 ~ 40 Chemical composition Silicia oxide SiO % Lithium oxide Li 2 O % 18 Potassium oxide K 2 O 1-4 % Phosphorous pentoxide P 2 O % 14 Aluminium oxide Al 2 O % Zirconium dioxide ZrO % 12 Ceria oxide CeO % Pigments 0-6 % VITA Suprinity Blocks Color Content 0M1-HT 5 pcs. EN1S A1-HT 5 pcs. EN1S A2-HT 5 pcs. EN1S A3-HT 5 pcs. EN1S Color Content A3.5-HT 5 pcs. EN1S B2-HT 5 pcs. EN1S C2-HT 5 pcs. EN1S D2-HT 5 pcs. EN1S Zfx Glass- and Hybrid ceramic Tools (Detailed information can be found on page 12 and 13.) Tool ID 0 Milling tool (mm) 0 Shaft (mm) Tool length (mm) Cutting depth (mm) T ZFX T ZFX T ZFX
34 Zfx Multi-Block Support As addition to the successful production unit Zfx Inhouse5x the Zfx Multi-Block Holder enables the processing of materials in block shape. Thus various units made of e.g. IPS e.max, VITA Suprinity, IPS Empress, can be clamped and processed in just one milling process. The holder can be equipped with up to 15 blocks. Zfx Multi-Block Support ZFX ,
35 Zfx Wax Zfx Wax The synthetic Zfx Wax Blanks are suitable for the fabrication of residue free combustible wax models. They are characterized by very good milling properties and form a fine shaving that didn t stick the milling tools (no medical device). Physical properties Dropping point C Densitiy at 20 C g / cm³ 0.97 Solvent contenct organic solvents % 0.0 Solid body content % 100 ø 98 ø Zfx Wax Blanks Dimension Art-No. Price ( ) 98 x 20 mm ZFX Zfx Wax Tools (Detailed information can be found on page 12 and 13.) Tool ID 0 Milling tool (mm) 0 Shaft (mm) Tool length (mm) Cutting depth (mm) T ZFX T ZFX T ZFX T ZFX
36 Zfx Accessories Zfx Scan Spray Superfine The Zfx Scan Spray Superfine prevents reflection for increased accuracy and speed. The spray is non-toxic and can be removed, leaving no residue, with water. Dimension 75 ml ZFX ml ZFX Zfx Sintering Beads The sinter plate is filled with a layer of sintering beads. This provides a sliding surface on which the zirconia structures can contract without distortion or tension during the sintering process. Article Dimension Zfx Sintering Beads 200 g ZFX Zfx Sinter Plate 98 mm ZFX Zfx sinter pearls (30-60 µm) for a precise sintering procedure 36
37 Zfx Digital-intraModel system The Zfx Digital-intraModel system enables the computer-aided production of physical models based on intraoral scans. The system consists of a software module used to define the emergence profile, segment the model and adjust the friction on the base plate, and the corresponding reusable base plates, pins and an intercuspidator. The resin models are produced in a Zfx milling center either using laser sintering or milling technology. The models are always delivered with suitable model analogs, which are positioned in the exact height and angle using a patented mechanism. Delivery contents Set 1 pc. Intercuspidator 2 pc. Zfx Plates 1 pc. Check Block 30 pc. Metal Pins 1 pc. Hex driver (HXLGR1.25), Long with GemLock for Zfx IntraScan Matchholders Art-No. Price ( ) Zfx Digital-intraModel system Set ZFX Additional component accessories Art-No. Price ( ) Torque wrench for Zfx Evolution Matchholders ZFX Hex driver, Long Standard for Zfx IntraScan Matchholders Torque wrench adapter without GemLock Hex driver, Long with GemLock Retention for Zfx IntraScan Matchholders with GemLock Retention HXL HXLGR Zfx Metal Pin Set (50 Pc.) ZFX Torque wrench for Matchholders of the Zfx Evolution series Hex driver, Long Standard for Zfx IntraScan Matchholders Hex driver, Long with GemLock Retention for Zfx IntraScan Matchholders Zfx Metal Pin Model analogue for all commonly used implant systems (detailed information on page 40 and 41) 37
38 Zfx Pre-Abutments Zfx Pre-Abutments With the Zfx Pre-Abutment Blanks Zfx provides the approprite Titanium Blanks (Great 5) with pre-manufactured connecting geometries for all common implant systems. The Pre-Abutment Processing Upgrade for the Zfx Inhouse5x offers the possibility to produce individual abutments in a time-saving and cost-effective manner in your own lab. Physical properties Relative Density g/cm Melting Point / Freezing Point F > 2,800 Chemical composition Titanium Ti % Aluminium Ai 3-6 % Vanadium V 2-4 % Copper Cu 0-3 % Tin Sn 0-2 % Zirconium Zi 0-1 % Zfx Pre-Abutment Blanks including screw Implant Systems Diameter (mm) Bone Level by Straumann Institut 3.3 ZFX Bone Level by Straumann Institut ZFX SynOcta by Straumann Institut 4.8 ZFX SynOcta by Straumann Institut 6.5 ZFX OsseoSpeed by Dentsply Implants (Astratech) 3.0 ZFX OsseoSpeed by Dentsply Implants (Astratech) ZFX OsseoSpeed by Dentsply Implants (Astratech) ZFX Replace by Nobel Biocare 3.5 ZFX Replace by Nobel Biocare 4.3 ZFX Replace by Nobel Biocare 5.0 ZFX Replace by Nobel Biocare 6.0 ZFX Active by Nobel Biocare 3.5 ZFX Active by Nobel Biocare ZFX
39 NEW Implant Systems Diameter (mm) Brånemark by Nobel Biocare 3.5 ZFX Brånemark by Nobel Biocare 4.1 ZFX Brånemark by Nobel Biocare 5.1 ZFX Frialit-Xive by Dentsply Implants 3.0 ZFX Frialit-Xive by Dentsply Implants 3.4 ZFX Frialit-Xive by Dentsply Implants 3.8 ZFX Frialit-Xive by Dentsply Implants ZFX EV by Dentsply Implants (Astratech) 3.0 ZFX EV by Dentsply Implants (Astratech) 3.6 ZFX EV by Dentsply Implants (Astratech) 4.2 ZFX EV by Dentsply Implants (Astratech) 4.8 ZFX EV by Dentsply Implants (Astratech) 5.4 ZFX Certain by Biomet 3i 3.4 ZFX Certain by Biomet 3i ZFX ExHex by Biomet 3i 3.4 ZFX ExHex by Biomet 3i ZFX Tapered Screw Vent by Zimmer 3.5 ZFX Tapered Screw Vent by Zimmer 4.5 ZFX Tapered Screw Vent by Zimmer 5.7 ZFX Eztetic Implant by Zimmer 2.9 ZFX Zfx Pre-Abutment Tools (Detailed information can be found on page 12 and 13.) Tool ID 0 Milling tool (mm) 0 Shaft (mm) Tool length (mm) Cutting depth (mm) T ZFX T ZFX T ZFX T ZFX T ZFX T ZFX T ZFX
40 Zfx System Components Implant abutments, bars and implant-supported screw-retained bridges which are 100 % compatible with the selected implant system are designed with the Zfx CAD software. A number of connector geometries which ensure compatibility with commonly used implant systems are stored in the library of the Zfx CAD software. The user first selects the implant used and then designs the implant structure. In doing so, the compatible connector type is automatically taken into account in the design proposed by the software. When modelling is complete, the entire data record for the design together with information on the titanium base is sent to the milling center where the required element is produced. Implant abutments are available with screwed or glued titanium base. The current cataogue with all components can be found at zfx-dental.com Zfx TM construction components Titanium bases with rotation protection (Regular Design and/or Small Design) Titanium bases without rotation protection (Regular Design and/or Small Design) Multi-Unit titanium bases Bridge screws for titanium, cobalt-chromium and zirconium constructions 40
41 Zfx compatible implant systems and types Implant manufacturer Implant Systems BIOMET 3I Certain Conical IOL Low Profile ExHex BIOHORIZONS Tapered Internal BREDENT SKY uni.cone SKY fast and fixed SKY CAMLOG Screw Line VARIO SR DENTSPLY IMPLANTS (ASTRATECH) OsseoSpeed UniAbutment DENTSPLY IMPLANTS Multi-Purpose Frialit-Xive MEGAGEN AnyRidge EZ Plus Rescue Internal MIS Internal Hex NOBEL BIOCARE Active Brånemark Multi-unit Replace OSSTEM GS & TS System P-I Amplified Conical Abutment External Hexagon Morse Taper STRAUMANN INSTITUT Bone Level Mutli-Base SynOcta Octa (External Octagon) SWEDEN & MARTINA Global Outlink² Premium Kohno THOMMEN MEDICAL SPI ZIMMER Tapered Screw Vent Shoulder Abutment SwissPlus Tapered Abutment Eztetic Implant PC. IN THE SET PC. IN THE SET PC. IN THE SET 44. Screws for zirconium and cobalt-chromium / titanium Evolution Matchholder IntraScan Matchholder in 2 sizes (H4 and H7) Model analogue (for digital and standard models) 41
42 Order form Delivery: Standard Express ( Service fee) Company: No. Zfx Art. No. Description Quantity Price in Euro Fax or via Company stamp Date: Signature: 42
43 Zfx Process Accuracy Highest fitting without sending models and black box! The Zfx Evolution series enables a measuring accuracy (VDI test procedure) in the solid of < 9 μm The two-piece Zfx Scan bodies for multiple usage without any deficit of accuracy are produced with an innovative code system, that enables the automatic recognition of the implant type and prevents application errors. Thus, in combination with the own-developped torque wrench for the Zfx Evolution series, an accuracy is ensured of < 5 μm PROCESS ACCURACY < 20 μm The industrial manufacturing with 5-axis simultaneous machining achieves an accuracy of < 5 μm 43
44 1055EN REV. 012/ Zfx GmbH. Irrtümer, Druckfehler und Priceänderungen vorbehalten. Zfx GmbH Kopernikusstraße Dachau, Germany Tel Fax
PRECISION, RELIABILITY, SIMPLICITY. simeda. customized. & solutions. Digital performance
PRECISION, RELIABILITY, SIMPLICITY simeda customized & solutions Digital performance 2 Simeda Scan The high-precision scanner for implantology! With, a company specialised in industrial metrology, Simeda
It s the Fuel For Your Success
It s the Fuel For Your Success Engineered For Success Today s patients demand aesthetic restorative outcomes that match or enhances their natural dentition. While this has traditionally been accomplished
Zfx & Zimmer Dental. Joining together for high-end dental prostheses
Zfx & Zimmer Dental Joining together for high-end dental prostheses Zfx & Zimmer Dental The new complete dental solution Cooperation: Zfx and Zimmer Dental join forces With Zfx as its CAD/CAM partner,
Precise. Powerful. Pure.
DATRON D1pure 2 Precise. Powerful. Pure. 3 DATRON Worldwide references p. 32 DATRON DentalCAM p.20 Scanners p.28 CAD p.28 4 Dental materials and Dental milling tools p. 24 DATRON D1 pure p. 7 We Understand
CAD/CAM. Solutions flexible, economical, future-proof
CAD/CAM Solutions flexible, economical, future-proof What would you like to use CAD/CAM solutions for today and tomorrow? Custom abutments Crown and bridge restorations Segments within prosthetics in the
STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment
STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES Straumann Anatomic IPS e.max Abutment The ITI (International Team for Implantology) is academic partner of Institut Straumann in the areas of research
all digital all options The right milling option High precision and productivity
all digital all options The innovative FULL CONTOUR milling system ZIRCONIA The right milling option High precision and productivity Customized digital solutions for every laboratory Preparation Scanners
DESS. Screws. Tijuana Ventas: (664) 685 6294/95 [email protected]. For all major implant systems!! www.dabocorp.com
Screws Screws for definitive use. Made from medical grade 5 ELI Titanium Integrity and soundness guaranteed by stress tests of up to 150% of their nominal torques. Their designs ensure a perfect fit with
ZIRCONIA INFORMATION FOR DENTISTS. FAQ S from the dental practice ENGLISH
ZIRCONIA INFORMATION FOR DENTISTS FAQ S from the dental practice ENGLISH Zr Facts and Answers 2 Facts and Answers What is Zirconia? Zirconium (ZrSiO ) belongs to the mineral group of silicates and 4 was
inlab SW 15 SOFTWARE FEATURES
inlab SW 15 SOFTWARE FEATURES This overview outlines the indications, tools, and materials according to the respective software versions starting with inlab SW 15.0. The respective changes to the previous
DS6000. Advanced Dental Scanner & CAD Software. Crowns, Bridges Wax-ups Implant Bridges and Bars High Accuracy Scan & Design
DS6000 Advanced Dental Scanner & CAD Software Crowns, Bridges Wax-ups Implant Bridges and Bars High Accuracy Scan & Design Inlay/Onlays DICOM Viewer Custom Abutments Virtual Articulator CAM Module DS6000
ATLANTIS abutments as individual as your patients
ATLANTIS abutments as individual as your patients ATLANTIS the freedom of unlimited possibilities Discover why ATLANTIS CAD/CAM abutments are the natural choice for patientspecific, cement-retained implant
CEREC inlab the multifunctional CAD/CAM system for modern dental restorations.
CEREC inlab the multifunctional CAD/CAM system for modern dental restorations. CEREC inlab technology CEREC inlab progress coupled with experience: Sirona s leading-edge CAD/CAM system. Sirona: a leading
Implant Parts. A Radford Heath Guide http://www.radfordheath.com 1
Implant Parts A Radford Heath Guide http://www.radfordheath.com 1 Disclaimer The information given in this document has been provided in good faith for basic information purposes only and the information
Regular C/X Prosthetics. Prosthetics
Regular C/X Prosthetics /X C/ Prosthetics ANKYLOS C/X Prosthetics For more than 20 years, the ANKYLOS system developed by Prof. Dr. G.-H. Nentwig and Dr. Dipl.-Ing. Walter Moser with its TissueCare Connection
IPS Empress CAD for CAD/CAM technology Information for Dentists. Confidence. Reliability. Esthetics. Empress CAD. The world s leading all-ceramic
CAD for CAD/CAM technology Information for Dentists Confidence Reliability Esthetics The world s leading all-ceramic A time-tested system with new possibilities More versatility with revolutionized the
Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT
Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT Introduction A 58 year old male had been missing teeth #7=12 for approximately 28 years. During
the new dna of high strength glass ceramics
the new dna of high strength glass ceramics 1 the new dna of high strength glass ceramics Together with the Fraunhofer Institute and VITA, we have developed a new class of materials for high-strength glassceramics
CAD/CAM MATERIAL. ALL FROM ONE SOURCE.
CAD/CAM MATERIAL. ALL FROM ONE SOURCE. SIRONA.COM 02 I 03 PRACTICAL EXPERIENCE. HARD TO BEAT. CEREC and inlab milling units from Sirona guarantee the economic and precise production of clinically sound
Abutment Solutions For customized implant restorations fabricated with CEREC and inlab. Digital all around.
Abutment Solutions For customized implant restorations fabricated with CEREC and inlab Digital all around. The digital treatment workflow Digital impression taking Coordinated digital workflows in CAD/CAM
October 29, 2015. Dear Ms. Hartnett:
DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Center WO66-G609 Silver Spring, MD 20993-0002 October 29, 2015 Ivoclar
Jacket crown. Advantage : Crown and Bridge
Crown and Bridge Lecture 1 Dr.Nibras AL-Kuraine Jacket crown It is a type of crown that is formed by a tooth colored material. It is mainly used as a single unit in the anterior quadrant of the mouth.
BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment
BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT Straumann Variobase Abutment 1 The ITI (International Team for Implantology) is academic partner of Institut Straumann AG in the areas of research
Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.
Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment. Dr. med. dent. David McFadden, Dallas County, USA Initial situation (single X-ray) Tooth 16
Simpl Implant Abutments with Atlantis CAD CAM Technology
Simpl Implant Abutments with Atlantis CAD CAM Technology Don t change your implant... change your abutment. See more patients in less time... and save money in the process! See how we ve made it Simpl.
ATLANTIS abutments design guide CAD/CAM patient-specific abutments
ATLANTIS abutments design guide CAD/CAM patient-specific abutments Contents Introduction 4 This manual helps you to explore all the benefits of ATLANTIS CAD/CAM patient-specific abutments. It gives you
New features DWOS 3.2
New features DWOS 3.2 Version 1.1 Septembre 13 th 2012 Summary This document describes how to use the new features and improvements of the release 3.2.0 of the Dental Wings Open Software (DWOS). Order
DENTAL CAD/CAM 3D PRINTERS
DENTAL CAD/CAM 3D PRINTERS Production of accurate, highly detailed dental prostheses, precision working models, drill guides and orthodontic thermoforming models Enter the Digital Dentistry Era ENHANCE
Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment
Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment by Dr. Ronald Jung and Master Dental Technician Xavier Zahno Initial situation
páêçå~=aéåí~ä=`^al`^j=póëíéã qá_~ëé
kéï=~ë=çñw MSKOMNS páêçå~=aéåí~ä=`^al`^j=póëíéã qá_~ëé lééê~íáåö=fåëíêìåíáçåë båöäáëü=erpf Operating Instructions = Table of contents Sirona Dental Systems GmbH Table of contents 1 Symbols used... 3 2
Press Abutment Solutions
Press Abutment Solutions Efficiency and esthetics redefined all ceramic all you need More press ceramic options... Press ceramics have been synonymous with the ideal combination of accuracy of fit, shape
WAX-UP AND CERAMIC EXTENSIVE COURSE Dr. Dario Adolfi Dr. Ivan Ronald Huanca
WAX-UP AND CERAMIC EXTENSIVE COURSE Dr. Dario Adolfi Dr. Ivan Ronald Huanca Duration: 6 meses STEP 1: WAX-UP OF FOUR UPPER POSTERIOR TEETH with Dr. Ivan Ronald Huanca The objective of this course s step
How to Achieve Shade Harmony With Different Restorations
Procera Alumina vs. Feldspathic Porcelain How to Achieve Shade Harmony With Different Restorations Luke S. Kahng, CDT Key Words: Stump shade, Feldspathic Porcelain, Zirconia, Alumina, LSK Treatment Plan
State-of-the-art for your prostheses
WHERE CREATIVITY meets technology E CREATECH EXCELLENCE State-of-the-art technology for your prostheses 1 CREATECH EXCELLENCE What is createch Excellence? Createch Excellence is OUR RANGE OF SOLUTIONS
A complete system geared to your success.
CAD/CAM SYSTEMS HANDPIECES HYGIENE SYSTEMS TREATMENT CENTRES IMAGING SYSTEMS CEREC AND inlab NEW PRODUCTS IN 2007 Dentistry at the turning point. CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS
ALL-CERAMIC DENTAL IMPLANT SOLUTIONS
ALL-CERAMIC DENTAL IMPLANT SOLUTIONS Scientific Evidence Bone-to-implant contact of 78% at 3 months. One piece implant = no prosthetic connections References 1. One-year follow-up of first consecutive
priti crown Your patients deserve you
priti crown Your patients deserve you 3 and you deserve the priti crown So close to nature priti crown is a high-tech solution for making perfect crown and bridge restorations using state-of-the-art CAD/CAM
IPS. Special Edition. Press-on-Metal Ceramic. Harald Gritsch Max Wörishofer Christoph Zobler
InLine PoM Press-on-Metal Ceramic IPS Special Edition Harald Gritsch Max Wörishofer Christoph Zobler Press-on technique on metal frameworks Combining the widely known casting technique and press technique
Seeing CAD/CAM in a new light.
CAD/ CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS CEREC NEW PRODUCTS 2009 Seeing CAD/CAM in a new light. T h e D e n t a l C o m p a n y Precision and simplicity redefined.
Choosing the right type of abutment
50 Producing custom implant abutments using CAD/CAM Choosing the right type of abutment S. KHALILOVA 1, F. KISTLER 2, S. ADLER 3, S. WEISS 3, S. KISTLER 2 AND J. NEUGEBAUER 2,4 Rapid developments in the
Implant solutions. 3M True Definition Scanner. Precise. implant impressions. with incredible speed
Implant solutions 3M True Definition Scanner Precise implant impressions with incredible speed True Definition Scanner You know in advance that it will be as desired The desired impression fast. The precise
CEREC MUCH MORE THAN RESTORATIONS.
CEREC MUCH MORE THAN RESTORATIONS. CEREC.com 02 I 03 CEREC. SINGLE VISIT DENTISTRY. CEREC has been developed to provide your patients with the best possible treatment during a single visit. You offer your
ATLANTIS ISUS the benchmark for CAD/CAM suprastructures. For all major implant systems
ATLANTIS ISUS the benchmark for CAD/CAM suprastructures For all major implant systems Patient satisfaction meets clinical benefits ATLANTIS delivers leading CAD/CAM patient-specific restorative solutions
NARROW DIAMETER implant
ND NARROW DIAMETER implant TABLE OF CONTENTS ND - NARROW DIAMETER implant Implant characteristics page 04 Dental implant page 05 Open Tray Impression Transfer page 06 Titanium Abutments page 07 O-Ball
Enter into the world of unprecedented accuracy! IScan D104 Series
Enter into the world of unprecedented accuracy! IScan D104 Series 2 Three scanners, one goal: Precisely fitting restorations The D104 Series of 3D scanning systems is the 5th generation of dental scanners
IPS e.max CAD C16. Larger Size Block Low translucency Shades: A1, A2, A3, A3.5, B1, B2, C1, C2, D2, BL2 Indicated for single unit restorations
IPS e.max CAD C16 IPS e.max CAD C16 Larger Size Block Low translucency Shades: A1, A2, A3, A3.5, B1, B2, C1, C2, D2, BL2 Indicated for single unit restorations Full and partial coverage single units Large
Restorative Guidelines
Restorative Guidelines Contents Restorative Guidelines 4.1 Neoss Implant System 4.2 4.2 Esthetiline Solution 4.3 4.3 Provisional Abutments 4.8 4.4 Impression Techniques Implant Level 4.12 4.5 NeoLink
Milled Bar Overdentures-Protocol and Procedures
Milled Bar Overdentures-Protocol and Procedures Dennis Urban, CDT When full implant dentures requiring a milled bar is prescribed, the proper protocol and procedure are of extreme importance. The proper
Full Denture System. Full denture prosthetics for dental technicians customised, precise, aesthetic
EN Full Denture System Full denture prosthetics for dental technicians customised, precise, aesthetic Customised and according to dental technology logic. PRECISE CONVENTIONAL IMPRESSION TAKING AUTOMATIC
Multi-unit abutment bar overdenture
This prosthetic technique module may contain references to the complete Prosthetic Manual (L02015). To download the full Prosthetic Manual, please visit www.biohorizons.com/prostheticmanual.aspx Use this
Dental System. Product Catalog
Dental System Product Catalog Please see price list for more details June 2015 Dental System Product Catalog Table of Contents Contents Page - 3Shape 3D Lab scanners 3-9 o D500 3D scanner with Dental System
screw-retained single crowns using custom-cast abutments
screw-retained single crowns using custom-cast abutments This prosthetic technique module may contain references to the complete Prosthetic Manual (L02015). To download the full Prosthetic Manual, please
all ceramic all options
all ceramic all options FULL CONTOUR CO ZIRCONIA Guidelines for dental technicians 5884 Zenostar Guideline Brochure V3.indd 1 7/19/13 9:56 AM Zenostar Full Contour Zirconia Restorations Your best option
Standard Internal Hex
Standard Internal Hex Touareg TM -OS Touareg TM -S Swell TM Touareg -S Touareg -OS Swell About ADIN Adin Dental Implant Systems Ltd., designs, manufactures and markets state of the art, technologically
Digital impression solutions. 3M True Definition Scanner. Precise. impressions. in a jiffy
Digital impression solutions 3M True Definition Scanner Precise impressions in a jiffy True Definition Scanner Digital impressioning redefined Easy handling. Desired result. With the 3M True Definition
Ceramics on Implants Fixed Zirconium Dioxide-Based Restorations in the Rehabilitation of the Edentulous upper Jaw
38 STARGET 1 I 11 ceramic restorations arne F. BOEcklER and MIcHaEl seitz Ceramics on Implants Fixed Zirconium Dioxide-Based Restorations in the Rehabilitation of the Edentulous upper Jaw Introduction
Advanced technology for your perfect smile!
Advanced technology for your perfect smile! Solutions for your highest expectations Welcome to the future of dental technology! Content The Company 03 Scanner 04 CAD 05 CAM 06 Support and training 07 340i
PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM
PROSTHETIC PROCEDURE for HG IMPLANT SYSTEM PROSTHETIC PROCEDURE for HG IMPLANT SYSTEM HG Implant System Contents Cement retained restoration Rigid abutment When abutment reduction is unnecessary When abutment
Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment
Contents TS Implant System Cement retained restoration Screw retained restoration 06 Cement-retained bridges with the Solid abutment system (non- 72 Screw retained crown with the ComOcta Gold abutment
Procedures & Products. NobelEsthetics
Procedures & Products NobelEsthetics First from Nobel Biocare. NobelPerfect, (NP, RP, WP), NobelDirect (NP, RP, WP), Brånemark System, NobelReplace and NobelSpeedy Implants. A complete assortment with
TEPZZ 69 _ZA T EP 2 692 310 A2 (19) (11) EP 2 692 310 A2. (12) EUROPEAN PATENT APPLICATION published in accordance with Art.
(19) TEPZZ 69 _ZA T (11) EP 2 692 3 A2 (12) EUROPEAN PATENT APPLICATION published in accordance with Art. 13(4) EPC (43) Date of publication: 0.02.14 Bulletin 14/06 (21) Application number: 1276632.0 (22)
INSPIRED BY NATURE: CHRISTIAN FERRARI FULL FUNCTIONAL AND ESTHETIC MINIMALINVASIV RESTORATION USING IPS E.MAX CERAMICS
DENTAVANTGART VOLUME IV ISSUE 03 AUTUMN 2014 INTERVIEW DR. VIOLETA BARTALIS ÉP. CLAUS & ZTM. JAN-HOLGER BELLMANN & DR. CARSTEN CLAUS DR. ATTILA BODROGI & CDT. SIMONE MAFFEI DR. CYRIL GAILLARD & CDT. JÉRÔME
páêçå~=aéåí~ä=`^al`^j=póëíéã på~åmçëí
kéï=~ë=çñw= MRKOMNP páêçå~=aéåí~ä=`^al`^j=póëíéã på~åmçëí lééê~íáåö=fåëíêìåíáçåë båöäáëü=erpf Operating Instructions = Sirona Dental Systems GmbH Table of contents 1 Symbols used... 3 2 Product description...
May 20, 2016. Ivoclar Vivadent Ag Ms. Donna Hartnett Director Regulatory Affairs Ivoclar Vivadent, Inc. 175 Pineview Drive Amherst, New York 14228
DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 May 20, 2016 Ivoclar
Basic Properties and Application of Auto Enamels
Basic Properties and Application of Auto Enamels Composition of Ceramic Automotive Glass Enamels Ceramic automotive glass colours are glass enamels that fire on to the glass during the bending process
Implants in your Laboratory: Abutment Design
1/2 point CDT documented scientific credit. See Page 41. Implants in your Laboratory: Abutment Design By Leon Hermanides, CDT A patient s anatomical limitations have the greatest predictive value for successful
Dr. Little received his doctorate degree in dentistry from UT Health at San Antonio Dental
Implant Solutions for the Implant Patient: Diagnosis and Treatment Planning for Predictable Results David Little, DDS 6961 U.S. Highway 87 East San Antonio, TX 78263 Phone: (210)648-4411 Fax: (210) 648-6498
Lapping and Polishing Basics
Lapping and Polishing Basics Applications Laboratory Report 54 Lapping and Polishing 1.0: Introduction Lapping and polishing is a process by which material is precisely removed from a workpiece (or specimen)
COATED CARBIDE. TiN. Al 2 O 3
COATED CARBIDE GENERAL INFORMATION CVD = Chemical Vapour Deposition coated grades GC2015, GC2025, GC2135, GC235, GC3005, GC3015, GC3020, GC3025, GC3115, GC4015, GC4025, GC4035, S05F, and CD1810. PVD =
Contact: Steve Hurson VP, R & D Nobel Biocare 22715 Savi Ranch Pkwy Yorba Linda, CA 92887 (714) 282-5072 steve.hurson@nobelbiocare.
Use of CP Titanium and Titanium alloys for Dental Implants Steve Hurson, Nobel Biocare U.S.A. Yorba Linda CA Abstract Professor Per Ingvar Branemark of Sweden published his results on 15 years of research
procedures & products NOBELESTHETICS including Procera
procedures & products NOBELESTHETICS including Procera First from Nobel Biocare. NOBELPERFECT, (NP, RP, WP), NOBELDIRECT (NP, RP, WP), Brånemark System, NOBELREPLACE and NOBELSPEEDY Implants. A complete
Tizian TM Creativ RT. Abutment Designer. for the CAD-software version 3.932. Instruction Manual
Tizian TM Creativ RT Abutment Designer for the CAD-software version 3.932 Instruction Manual Schütz Dental GmbH 61191 Rosbach, Germany Tel.: +49 6003 / 814-0 Fax: +49 6003 / 814-906 Version: 12/2010 Contents
Advances in All Ceramic Restorations. Alaa AlQutub Umm AlQura University, Faculty of Dentistry
Advances in All Ceramic Restorations Alaa AlQutub Umm AlQura University, Faculty of Dentistry Types of materials used in esthetic zone I. Metal ceramic restoration: Metal ceramic alloy features : Produce
Dental Intelligence. dd TECHNIQUE. The Material. First Experiences with the One Body System IQ from GC
First Experiences with the One Body System IQ from GC Dental Intelligence An article by Michael Brüsch, MDT, Düsseldorf, Germany High quality is not enough anymore; price is ruling the market. Such circumstances
FABRICATING CUSTOM ABUTMENTS
FABRICATING CUSTOM ABUTMENTS LUC AND PATRICK RUTTEN How much should a Dental Technician know about the clinical aspects of implantology? The answer is clear: as much as possible. This is the distinction
MEDICAL TECHNOLOGY IN IMPRESSIVE 3D
MEDICAL TECHNOLOGY IN IMPRESSIVE 3D ABOUT 3D MEDICAL PRINT As a master dental technician with my own dental lab, I have always been looking for further education and innovative techniques in the medical
Sinterstation. Pro Direct Metal SLM System
Sinterstation Pro Direct Metal SLM System Jim Dier SLS and SLM Systems, Upper Midwest 3D Systems, Inc. 18 July 2008 Introduction Product overview Systems Sinterstation Pro DM100 SLM System Sinterstation
A Review of Implant Abutments - Abutment Classification to Aid Prosthetic Selection
A Review of Implant Abutments - Abutment Classification to Aid Prosthetic Selection Sanjay Karunagaran, B.D.S., D.D.S., M.S.D., Gregory J. Paprocki, D.D.S., Russell Wicks, D.D.S., M.S., Sony Markose, B.D.S.,
All-on-4 treatment concept with NobelSpeedy Groovy
All-on-4 treatment concept with NobelSpeedy Groovy Product overview Immediate Function for high patient satisfaction Immediately loaded fixed provisional prosthesis on the day of surgery. Immediate improvement
Dental Implants. You are correct, it is a labeling error. Here is your dental prosthesis!!!
Dental Implants You are correct, it is a labeling error. Here is your dental prosthesis!!! Manufacturing process of bridges, crowns, bone implants, fixtures, abutments. Manufacturing process of bridges,
Implants of high-performance ceramic. vk-lange 12.03.2007 14:44 Uhr Seite 1. One-piece precision implant. Made in Germany
OMNIS Implants of high-performance ceramic vk-lange 12.03.2007 14:44 Uhr Seite 1 One-piece precision implant C M Y CM MY CY CMY K Dieter Lange Verkaufsleiter Labor Made in Germany creamed nge 12.03.2007
CAD/CAM technology supporting successful implant therapy
CAD/CAM technology supporting successful implant therapy Suheil M. Boutros, DDS, MS, Manuel Fricke, DT Modern implantology opens up new treatment options for individuals with only minimal or no remaining
WHAT S NEW IN DENTAL SYSTEM 2015
Many call it the most powerful CAD / CAM solution in the world. Others prefer to speak of its efficient workflows, many tools, ease of use, and complete range of indications. No matter how you describe
TRIOS Digital Impression Solution
Digital Impression Solution 5 reasons to choose TRIOS is more than an impression Superior scanning technologies Flexible hardware configurations Widest range of indications Open and flexible for any lab
sets for several machines:
sets for several machines: avamill-chrome Datron D5 Datron m7 DEntaL ConCEPt systems DC5 DooWoon DYamaCH DYamaCH Dt 2 Gf agie CHarmILLEs mikron Hsm 400 HInt-ELs ImEs-ICorE mb maschinen organical röders
TechCut 4 Precision Low Speed Saw
Product Brochure TechCut 4 Precision Low Speed Saw 3" - 6" Blade Range Digital Speed Display 1-Micron Sample Indexing Spring-Loaded Dressing Stick Attachment All Aluminum & Stainless Steel Construction
Projecting a new smile from a facial photograph:
I special _ digital smile design Projecting a new smile from a facial photograph: A new way to plan multidisciplinarydental treatments Authors_ Drs Marco Del Corso, Italy, & Alain Méthot, Canada without
ATLANTIS crown abutment. Patient-specific CAD/CAM abutments for single-tooth, screw-retained restorations
ATLANTIS crown abutment Patient-specific CAD/CAM abutments for single-tooth, screw-retained restorations Excellent results every time For all major implant systems DENTSPLY Implants now offers the appreciated
Crown and Bridge Restorations. Straumann synocta Prosthetic System
Crown and Bridge Restorations Straumann synocta Prosthetic System The ITI (International Team for Implantology) is academic partner of Institut Straumann AG in the areas of research and education. Contents
Think precision, Think HSS REAMING
Think precision, Think HSS REAMING SUMMARY REAMING TOOLS 2 Zoom on a reamer 3 Which HSS for maximum efficiency? 4 Coatings for the best performance 5 Vocabulary 6 Choose the right design 7 Types of bevel
Rebilda DC. Rebilda Post System. Rebilda
Rebilda DC Rebilda Post System Rebilda Rebilda DC Systematic coronal build-up reconstruction Nowadays, modern composite and adhesive systems enable the reconstruction of severely damaged teeth, even if
Titanium versus Zirconium Implants
Titanium versus Zirconium Implants A dental materials comparison Dr. Gerald Regni, DMD!!" Christian St. Phila. PA 1213" T: (""") %&'-!"#" E: [email protected] Titanium versus Zirconium Implants
Material data sheet. EOS StainlessSteel GP1 for EOSINT M 270. Description, application
EOS StainlessSteel GP1 for EOSINT M 270 A number of different materials are available for use with EOSINT M systems, offering a broad range of e-manufacturing applications. EOS StainlessSteel GP1 is a
THE ZENOSTAR CONCEPT. Guidelines for dental technicians / clinicians. www.zenostar.de VOLLANATOMIE FULL CONTOUR
THE ZENOSTAR CONCEPT Guidelines for dental technicians / clinicians VOLLANATOMIE FULL CONTOUR www.zenostar.de VOLLANATOMIE FULL CONTOUR Zenostar dental restorations from Wieland Dental The clear monolithic
your talent. our technology. the perfect fit.
your talent. our technology. the perfect fit. itero - exclusively distributed in Europe by The digital revolution Changing the Face of Dentistry Digital technology ensures a more accurate impression from
Optimet 3D Dental Multi-Facet Scanner Attainable Accuracy for Dental Application Cases
Optimet 3D Dental Multi-Facet Scanner Attainable Accuracy for Dental Application Cases Optimet Dental 3D Scanner This paper presents an overview of the Optimet multi-facet Dental Scanner used for 3D scanning
PROSTHETICS. Crown and Bridge Restorations with the synocta Prosthetic System DENTAL IMPLANT SYSTEM
PROSTHETICS Crown and Bridge Restorations with the synocta Prosthetic System DENTAL IMPLANT SYSTEM IMPORTANT NOTES Disclaimer of liability The ITI dental implant is part of an overall concept and may only
