1 Revision of ANSI/ESD S For the Development of an Electrostatic Discharge Control Program for Protection of Electrical and Electronic Parts, Assemblies and Equipment (Excluding Electrically Initiated Explosive Devices) Electrostatic Discharge Association 7900 Turin Road, Bldg. 3 Rome, NY An American National Standard Approved March 1, 2007
2 ESD Association Standard for the Development of an Electrostatic Discharge Control Program for Protection of Electrical and Electronic Parts, Assemblies and Equipment (Excluding Electrically Initiated Explosive Devices) Approved February 11, 2007 ESD Association
3 CAUTION NOTICE Electrostatic Discharge Association (ESDA) standards and publications are designed to serve the public interest by eliminating misunderstandings between manufacturers and purchasers, facilitating the interchangeability and improvement of products and assisting the purchaser in selecting and obtaining the proper product for his particular needs. The existence of such standards and publications shall not in any respect preclude any member or non-member of the Association from manufacturing or selling products not conforming to such standards and publications. Nor shall the fact that a standard or publication is published by the Association preclude its voluntary use by non-members of the Association whether the document is to be used either domestically or internationally. Recommended standards and publications are adopted by the ESDA in accordance with the ANSI Patent policy. Interpretation of ESDA Standards: The interpretation of standards in-so-far as it may relate to a specific product or manufacturer is a proper matter for the individual company concerned and cannot be undertaken by any person acting for the ESDA. The ESDA Standards Chairman may make comments limited to an explanation or clarification of the technical language or provisions in a standard, but not related to its application to specific products and manufacturers. No other person is authorized to comment on behalf of the ESDA on any ESDA Standard. DISCLAIMER OF WARRANTIES THE CONTENTS OF ESDA S STANDARDS AND PUBLICATIONS ARE PROVIDED AS- IS, AND ESDA MAKES NO REPRESENTATIONS OR WARRANTIES, EXPRESS OR IMPLIED, OF ANY KIND WITH RESPECT TO SUCH CONTENTS. ESDA DISCLAIMS ALL REPRESENTATIONS AND WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE OR USE, TITLE AND NON-INFRINGEMENT. DISCLAIMER OF GUARANTY: ESDA STANDARDS AND PUBLICATIONS ARE CONSIDERED TECHNICALLY SOUND AT THE TIME THEY ARE APPROVED FOR PUBLICATION. THEY ARE NOT A SUBSTITUTE FOR A PRODUCT SELLER S OR USER S OWN JUDGMENT WITH RESPECT TO ANY PARTICULAR PRODUCT DISCUSSED, AND ESDA DOES NOT UNDERTAKE TO GUARANTY THE PERFORMANCE OF ANY INDIVIDUAL MANUFACTURERS PRODUCTS BY VIRTUE OF SUCH STANDARDS OR PUBLICATIONS. THUS, ESDA EXPRESSLY DISCLIAMS ANY RESPONSIBILITY FOR DAMAGES ARISING FROM THE USE, APPLICATION, OR RELIANCE BY OTHERS ON THE INFORMATION CONTAINED IN THESE STANDARDS OR PUBLICATIONS. LIMITATION ON ESDA S LIABILITY: NEITHER ESDA, NOR ITS MEMBERS, OFFICERS, EMPLOYEES OR OTHER REPRESENTATIVES WILL BE LIABLE FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR MISUSE OF ESDA STANDARDS OR PUBLICATIONS, EVEN IF ADVISED OF THE POSSIBILITY THEREOF. THIS IS A COMPREHENSIVE LIMITATION OF LIABILITY THAT APPLIES TO ALL DAMAGES OF ANY KIND, INCLUDING WITHOUT LIMITATION, LOSS OF DATA, INCOME OR PROFIT, LOSS OF OR DAMAGE TO PROPERTY AND CLAIMS OF THIRD PARTIES. Published by: Electrostatic Discharge Association 7900 Turin Road, Bldg. 3 Rome, NY Copyright 2007 by ESD Association All rights reserved No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher. Printed in the United States of America ISBN:
4 (This foreword is not part of ANSI/ESD S ) FOREWORD This standard covers the requirements necessary to design, establish, implement and maintain an Electrostatic Discharge (ESD) Control Program for activities that manufacture, process, assemble, install, package, label, service, test, inspect or otherwise handle electrical or electronic parts, assemblies and equipment susceptible to damage by electrostatic discharges greater than or equal to 100 volts Human Body Model (HBM). This document covers the ESD Control Program requirements and offers guidance for setting up a program to handle ESD sensitive (ESDS) items, based on the historical experience of both military and commercial organizations. References include ESD Association, U.S. Military and ANSI approved standards for material properties and test methods. The fundamental ESD control principles that form the basis of this document are: A. All conductors in the environment, including personnel, shall be bonded or electrically connected and attached to a known ground or contrived ground (as on shipboard or on aircraft). This attachment creates an equipotential balance between all items and personnel. Electrostatic protection can be maintained at a potential above a zero voltage ground potential as long as all items in the system are at the same potential. B. Necessary non-conductors in the environment cannot lose their electrostatic charge by attachment to ground. Ionization systems provide neutralization of charges on these necessary non-conductive items (circuit board materials and some device packages are examples of necessary non-conductors). Assessment of the ESD hazard created by electrostatic charges on the necessary nonconductors in the work place is required to ensure that appropriate actions are implemented, commensurate with risk to ESDS items. C. Transportation of ESDS items outside an ESD Protected Area (hereafter referred to as EPA ) requires enclosure in static protective materials, although the type of material depends on the situation and destination. Inside an EPA, low charging and static dissipative materials may provide adequate protection. Outside an EPA, low charging and static discharge shielding materials are recommended. While these materials are not discussed in the document, it is important to recognize the differences in their application. For more clarification see ANSI/ESD S541. Any relative motion and physical separation of materials or flow of solids, liquids or particle-laden gases can generate electrostatic charges. Common sources of ESD include personnel, items made from common polymeric materials, and processing equipment. ESD damage can occur when: i. A charged object comes into contact with an ESDS device, or ii. An ESDS device is grounded while exposed to an electrostatic field. Examples of ESDS parts are microcircuits, discrete semiconductors, thick and thin film resistors, hybrid devices, printed circuit boards and piezoelectric crystals. It is possible to determine device and item susceptibility by exposing the device to simulated ESD events. The level of sensitivity, determined by testing using simulated ESD events, may not necessarily relate to the level of sensitivity in a real life situation. However, they are used to establish a baseline of susceptibility data for comparison of devices with equivalent part numbers from different manufacturers. Three different models are used for characterization of electronic components: HBM, Machine Model (MM), and Charged Device Model (CDM). i
5 This document was originally designated ANSI/ESD S and approved on August 4, ANSI/ESD S was prepared by the Mil-Std 1686 Conversion Committee. ANSI/ESD S is a revision of ANSI/ESD S and was prepared by the S20.20 Writing Team, which consists of the following members: Ron Gibson Celestica Steve Gerken USAF John T. Kinnear Jr. IBM The following individuals made significant contributions to this document: Jeremy Smallwood Electrostatic Solutions Ltd. Reinhold Gaertner Infineon Technologies At the time the S version was prepared, the Mil-Std 1686 Conversion Committee had the following members: Steve Gerken, Co-Chairman USAF Anthony Klinowski Boeing Dave Leeson, Co-Chairman Motorola SSTG Garry McGuire NASA (Hernandez Engineering) Thomas Mohler Raytheon Systems Corporation David E. Swenson 3M Ron Gibson Celestica The following individuals made significant contributions to this document: Ronald L. Johnson Intel Donald E. Cross USN Jeffrey Scanlon ASC Robert Parr Consultant Sheryl Zayic Boeing John T. Kinnear Jr. IBM Joel Weidendorf Consultant Robert Cummings NASA Ralph Myers ASC ii
6 TABLE OF CONTENTS 1.0 PURPOSE SCOPE REFERENCED PUBLICATIONS DEFINITIONS PERSONNEL SAFETY ESD CONTROL PROGRAM ESD CONTROL PROGRAM REQUIREMENTS ESD CONTROL PROGRAM MANAGER OR COORDINATOR TAILORING ESD CONTROL PROGRAM ADMINISTRATIVE REQUIREMENTS ESD CONTROL PROGRAM PLAN TRAINING PLAN COMPLIANCE VERIFICATION PLAN ESD CONTROL PROGRAM PLAN TECHNICAL REQUIREMENTS GROUNDING / EQUIPOTENTIAL BONDING SYSTEMS PERSONNEL GROUNDING ESD PROTECTED AREAS (EPAS) PACKAGING MARKING... 7 ANNEX A ADDITIONAL PROCESS CONSIDERATIONS... 8 ANNEX B ESD SENSITIVITY TESTING... 9 ANNEX C RELATED DOCUMENTS TABLES Table 1. Grounding / Equipotential Bonding Requirements... 4 Table 2. Personnel Grounding Requirement... 4 Table 3. EPA ESD Control Items... 6 Table 4. ESD Susceptibility Test References for Devices Table 5. ESD Susceptibility Test References for Assemblies and Equipment iii
7 ESD Association Standard ANSI/ESD S ESD Association Standard for the Development of an Electrostatic Discharge Control Program for Protection of Electrical and Electronic Parts, Assemblies and Equipment (Excluding Electrically Initiated Explosive Devices) 1.0 PURPOSE The purpose of this standard is to provide administrative and technical requirements for establishing, implementing and maintaining an ESD Control Program (hereafter referred to as the Program ). 2.0 SCOPE This document applies to activities that manufacture, process, assemble, install, package, label, service, test, inspect, transport or otherwise handle electrical or electronic parts, assemblies and equipment susceptible to damage by electrostatic discharges greater than or equal to 100 volts HBM. Activities that handle items that are susceptible to less than 100 volts HBM may require additional control elements or adjusted limits. Processes designed to handle items that have an ESD sensitivity less than 100 volts HBM can still claim compliance to this standard. This document does not apply to electrically initiated explosive devices, flammable liquids or powders. 3.0 REFERENCED PUBLICATIONS Unless otherwise specified, the following documents of the latest issue, revision or amendment form a part of this standard to the extent specified herein: ESD ADV1.0, ESD Association s Glossary of Terms 1 ANSI/ESD S1.1, Wrist Straps 1 ANSI/ESD STM2.1, Garments 1 ANSI/ESD STM3.1, Ionization 1 ANSI/ESD SP3.3, Periodic Verification of Air Ionizers 1 ANSI/ESD S4.1, Worksurfaces Resistance Measurements 1 ANSI/ESD STM4.2, ESD Protective Worksurfaces Charge Dissipation Characteristics 1 ANSI/ESD S6.1, Grounding 1 ANSI/ESD S7.1, Floor Materials Characterization of Materials 1 ANSI/ESD STM9.1, Footwear Resistive Characterization 1 ESD SP9.2, Footwear Foot Grounders Resistive Characterization 1 ANSI/ESD STM97.1, Floor Materials and Footwear Resistance Measurement in Combination with a Person 1 ANSI/ESD STM97.2, Floor Materials and Footwear Voltage Measurement in Combination with a Person 1, Compliance Verification of ESD Protective Equipment and Materials 1 ANSI/ESD STM12.1, Seating Resistive Measurement 1 ANSI/ESD S541, Packaging Materials for ESD Sensitive Items 1 1 ESD Association, 7900 Turin Road, Bldg. 3, Ste. 2, Rome, NY ,
8 4.0 DEFINITIONS The terms used in the body of this document are in accordance with the definitions found in ESD ADV1.0, ESD Association s Glossary of Terms. 5.0 PERSONNEL SAFETY The procedures and equipment described in this document may expose personnel to hazardous electrical conditions. Users of this document are responsible for selecting equipment that complies with applicable laws, regulatory codes and both external and internal policy. Users are cautioned that this document cannot replace or supersede any requirements for personnel safety. Ground fault circuit interrupters (GFCI) and other safety protection should be considered wherever personnel might come into contact with electrical sources. Electrical hazard reduction practices should be exercised and proper grounding instructions for equipment shall be followed. 6.0 ESD CONTROL PROGRAM 6.1 ESD Control Program Requirements The Program shall include both administrative and technical requirements as described herein. The most sensitive level of the items to be handled, in accordance with the Program, shall be documented. The Organization shall establish, document, implement, maintain and verify the compliance of the Program in accordance with the requirements of this document. 6.2 ESD Control Program Manager or Coordinator An ESD Control Program Manager or Coordinator shall be assigned by the Organization to verify the compliance of the Program in accordance with the requirements of this document. 6.3 Tailoring This document, or portions thereof, may not apply to all applications. Tailoring is accomplished by evaluating the applicability of each requirement for the specific application. Upon completion of the evaluation, requirements may be added, modified or deleted. Tailoring decisions, including rationale and technical justifications, shall be documented in the ESD Control Program Plan. 7.0 ESD CONTROL PROGRAM ADMINISTRATIVE REQUIREMENTS 7.1 ESD Control Program Plan The Organization shall prepare an ESD Control Program Plan that addresses each of the requirements of the Program. Those requirements include: Training Compliance Verification Grounding / Equipotential Bonding Systems Personnel Grounding EPA Requirements Packaging Systems Marking 2
9 The ESD Control Program Plan is the principal document for implementing and verifying the Program. The goal is a fully implemented and integrated Program that conforms to internal quality system requirements. The ESD Control Program Plan shall apply to all applicable facets of the Organization s work. 7.2 Training Plan Initial and recurrent ESD awareness and prevention training shall be provided to all personnel who handle or otherwise come into contact with any ESDS items. Initial training shall be provided before personnel handle ESDS items. The type and frequency of ESD training for personnel shall be defined in the Training Plan. The Training Plan shall include a requirement for maintaining employee training records and shall document where the records are stored. Training methods and the use of specific techniques are at the Organization s discretion. The training plan shall include the methods used by the Organization to verify trainee comprehension and training adequacy. 7.3 Compliance Verification Plan A Compliance Verification Plan shall be established to ensure the Organization s fulfillment of the technical requirements of the ESD Control Program Plan. Process monitoring (measurements) shall be conducted in accordance with a Compliance Verification Plan that identifies the technical requirements to be verified, the measurement limits and the frequency at which those verifications shall occur. The Compliance Verification Plan shall document the test methods and equipment used for process monitoring and measurements. If the test methods used by the Organization differ from any of the standards referenced in this document, then there must be a tailoring statement that is documented as part of the ESD Control Program Plan. Compliance verification records shall be established and maintained to provide evidence of conformity to the technical requirements. The test equipment selected shall be capable of making the measurements defined in the Compliance Verification Plan. 8.0 ESD CONTROL PROGRAM PLAN TECHNICAL REQUIREMENTS The following sections, Sections 8.1 to 8.5, describe the key technical requirements used in the development of an ESD Control Program. The required limits are based on the test methods or standards listed in each table. The Compliance Verification Plan shall document the methods used to verify the limits. 8.1 Grounding / Equipotential Bonding Systems Grounding / Equipotential Bonding Systems shall be used to ensure that ESDS items, personnel and any other conductors (e.g., mobile equipment) are at the same electrical potential. An implementing process shall be selected from Table 1. 3
10 Table 1. Grounding / Equipotential Bonding Requirements Technical Requirement Implementing Process Test Method Required Limit(s) Grounding / Bonding System Equipment Grounding Conductor ANSI/ESD S6.1 < 1.0 ohm impedance Auxiliary Ground ANSI/ESD S6.1 < 25 ohms to the Equipment Grounding Conductor Equipotential Bonding ANSI/ESD S6.1 < 1.0 x 10 9 ohms 1 1 The maximum resistance between any ESD technical element and the common connection point. 8.2 Personnel Grounding All personnel shall be bonded or electrically connected to the grounding / equipotential bonding system when handling ESDS items. The personnel grounding method(s) shall be selected from Table 2. NOTE: Use of a garment to achieve personnel grounding shall be documented in the ESD Control Program Plan. The garment shall be electrically conductive from one sleeve to the next and must also meet the system resistance requirements defined in Note 2 in Table 2. When personnel are seated at ESD protective workstations, they shall be connected to the grounding / equipotential bonding system via a wrist strap system. For standing operations, personnel shall be grounded via a wrist strap system or by a flooringfootwear system. When a flooring-footwear system is used, one of the two following conditions shall be met: A. When the total resistance of the system (from the person, through the footwear and flooring to the grounding / equipotential bonding system) is less than 3.5 x 10 7 ohms, Method 1 shall be followed (see Table 2). B. When the total resistance of the system (from the person, through the footwear and flooring to the grounding / equipotential bonding system) is greater than 3.5 x 10 7 ohms and less than 1 x 10 9 ohms, Method 2 shall be followed (see Table 2). Table 2. Personnel Grounding Requirement Personnel Grounding Technical Requirement Wrist Strap ANSI/ESD S1.1 System 2 (Section 5.11) Flooring / Footwear System Method 1 Flooring / Footwear System Method 2 (both required) Product Qualification 1 Compliance Verification Test Method Required Limit(s) Test Method Required Limit(s) ANSI/ESD STM97.1 ANSI/ESD STM97.1 ANSI/ESD STM97.2 < 3.5 x 10 7 ohms < 3.5 x 10 7 ohms < 10 9 ohms < 100 volts Wrist Strap Section Flooring Section Footwear Section Flooring Section Footwear Section < 3.5 x 10 7 ohms < 3.5 x 10 7 ohms < 3.5 x 10 7 ohms < 1.0 x 10 9 ohms < 1.0 x 10 9 ohms 1 Product qualification is normally conducted during the initial selection of ESD control products and materials. Any of the following methods can be used: product specification review, independent laboratory evaluation or internal laboratory evaluation. 2 For situations where an ESD garment is used as part of the wrist strap grounding path, the total system resistance including the person, garment and grounding cord shall be less than 3.5 x 10 7 ohms. 4
11 8.3 ESD Protected Areas (EPAs) Handling of ESDS parts, assemblies and equipment without ESD protective covering or packaging shall be performed in an EPA. Caution signs indicating the existence of the EPA shall be posted and clearly visible to personnel prior to entry to the EPA. NOTE: An EPA can consist of a single workstation, entire room or building. Access to the EPA shall be limited to personnel who have completed appropriate ESD training. Untrained individuals shall be escorted by trained personnel while in an EPA. In order to mitigate field-induced CDM damage, the ESD program shall include a plan for the handling of process-required insulators. If the field exceeds 2,000 volts/inch, steps shall be taken to either: A) Separate the insulator from the ESD-sensitive device by a distance of 30 cm (12 inches); or B) Use ionization or other charge mitigating techniques to neutralize the charge. NOTE: The accurate measurement of electrostatic fields requires that the person making the measurement is familiar with the operation of the measuring equipment. Most hand held meters require that the reading be taken at a fixed distance from the object. They also normally specify that the object has a minimum dimension of fixed size in order to get an accurate reading. All nonessential insulators such as coffee cups, food wrappers and personal items shall be removed from the workstation or any operation where unprotected ESDS items are handled. An EPA shall be established wherever ESDS products are handled. However, there are many different ways to establish ESD controls within an EPA. Table 3 lists some optional ESD control items which can be used to control static electricity. For those ESD control items that are selected for use in the ESD Control Program, the required limits and test methods for that item becomes mandatory. 5
12 Table 3. EPA ESD Control Items Technical Requirement EPA ESD Control Item Worksurface Wrist Strap Cord Wrist Strap Cuff Product Qualification 1 Test Method ANSI/ESD S 4.1 and/or ANSI/ESD STM 4.2 ANSI/ESD S1.1 ANSI/ESD S1.1 Required Limit(s) 2 < 1 x 10 9 ohms and/or < 200 volts 0.8 x 10 6 to 1.2 x 10 6 ohms Interior < 1 x 10 5 ohms Exterior > 1 x 10 7 ohms Compliance Verification Test Method Worksurface Section Required Limit(s) < 1 x 10 9 ohms resistance to ground For compliance verification of a wrist strap system, see Table 2. Wrist Strap Cord Bending Life ANSI/ESD S1.1 > 16,000 cycles Footwear ANSI/ESD STM9.1 < 1 x 10 9 ohms See Table 2 See Table 2 Foot Grounders ESD SP9.2 < 1 x 10 9 ohms See Table 2 See Table 2 Flooring ANSI/ESD S7.1 < 1 x 10 9 ohms See Table 2 See Table 2 Seating Ionization other than Room Systems Ionization (Room Systems) ANSI/ESD STM 12.1 ANSI/ESD STM Discharge time - Offset voltage ANSI/ESD STM3.1 - Discharge time - Offset voltage < 1 x 10 9 ohms User defined < ± 50 volts User defined < ± 150 volts Shelving ANSI/ESD S4.1 < 1 x 10 9 ohms Mobile Equipment (Working Surfaces) Continuous Monitors Garments ANSI/ESD S4.1 User defined Static Control Garment (ANSI/ESD STM2.1) Groundable Static Control Garment (ANSI/ESD STM2.1) Groundable Static Control Garment System (ANSI/ESD STM2.1) < 1 x 10 9 ohms User defined < 1 x ohms < 1 x 10 9 ohms < 3.5 x 10 7 ohms Seating Section 3 - Discharge time - Offset voltage 3 - Discharge time - Offset voltage Worksurface Section Mobile Equipment Section Continuous Monitors Section Garments Section Garments Section Garments Section < 1 x 10 9 ohms resistance to ground User defined < ± 50 volts User defined < ± 150 volts < 1 x 10 9 ohms resistance to ground < 1 x 10 9 ohms resistance to ground Manufacturer defined < 1 x ohms < 1 x 10 9 ohms < 3.5 x 10 7 ohms 1 Product qualification is normally conducted during the initial selection of ESD control products and materials. Any of the following methods can be used: product specification review, independent laboratory evaluation or internal laboratory evaluation. 2 For standards that have multiple resistance test methods, these limits apply to all methods. 3 For additional information on periodic testing of Ionizers, see ANSI/ESD SP3.3. 6
13 8.4 Packaging ESD protective packaging shall be in accordance with the contract, purchase order, drawing or other documentation. When not specified by the above documentation, the organization shall define ESD protective packaging requirements, both inside and outside the EPA per ANSI/ESD S Marking ESDS items, system or packaging marking shall be in accordance with customer contracts, purchase orders, drawing or other documentation. When the contract, purchase order, drawing or other documentation does not define ESDS items, system or packaging marking, the Organization, in developing the ESD Control Program Plan, shall consider the need for marking. If it is determined that marking is required, it shall be documented as part of the ESD Control Program Plan. 7
14 (This annex is not part of ANSI/ESD S ) ANNEX A ADDITIONAL PROCESS CONSIDERATIONS The following sections provide guidance and outline documents that are available to help the users evaluate additional control products and equipment. Users will need to develop their own acceptance and compliance verification criteria as the industry has not yet defined required limits for these items. 1. Automated Handlers (ESD SP10.1, Automated Handling Equipment [AHE]). To demonstrate ESD control in automated handling equipment, it may be necessary to measure resistance to ground of machine components and monitor or verify electrostatic charge on product as it passes through the equipment. This can provide both continuous verification of ESD counter-measures and a method for locating sources of charge generation. This standard practice covers resistance-to-ground of machine components and sources of charge in automated handling equipment. 2. Gloves (ANSI/ESD SP15.1, Standard Practice for In-Use Resistance Testing of Gloves and Finger Cots). This standard practice is intended to provide test procedures for measuring the intrinsic electrical resistance of gloves and finger cots; and electrical resistance of gloves or finger cots and personnel together as a system. This standard practice applies to all gloves and finger cots used to control ESD. This standard practice provides data that are relevant in the user s specific environment and application. 3. Hand Tools (ESD STM13.1, Electrical Soldering/Desoldering Hand Tools). This standard test method provides electric soldering/desoldering hand tool test methods for measuring electrical leakage and tip to ground reference point resistance. The standard test method provides parameters for electrical overstress (EOS) safe soldering operation. Even though not specifically discussed in STM13.1, battery powered, pneumatic and other hand tools may also need to be evaluated. 4. ESD Handbook (TR20.20). The ESD Association Standards Committee produced this ESD Handbook for individuals and organizations that are faced with controlling electrostatic discharge (ESD). It provides guidance that can be used for developing, implementing and monitoring an electrostatic discharge control program in accordance with ANSI/ESD S This Handbook applies to activities that: manufacture, process, assemble, install, package, label, service, test, inspect or otherwise handle electrical or electronic parts, assemblies and equipment susceptible to damage by electrostatic discharges greater than or equal to 100 volts Human Body Model. 8
15 ANNEX B ESD SENSITIVITY TESTING (This annex is not part of ANSI/ESD S ) Assessing the ESD sensitivity of parts, assemblies and equipment and their required protection levels can be an important element of an ESD Control Program. A common method for establishing ESD sensitivity limits is to use one or more of the three ESD models (HBM, MM and CDM) for characterization of electronic items. The selection of specific ESD control procedures or materials is at the option of the ESD Control Program Plan preparer and should be based on risk assessment and the established electrostatic discharge sensitivities of parts, assemblies, and equipment. Technical literature and failure analysis data exist that indicate ESD failures are due to a complex series of interrelated effects. Some of the factors that influence ESD sensitivity include the ESD current and energy envelope, the rise time of the ESD event, device design, fabrication technology and device package style. Energy sensitive devices are damaged by currents through the resistance of a bipolar junction, protection resistor, or protection MOS transistor. Voltage sensitive devices are damaged when the breakdown voltage across the gate oxide is exceeded. ESD sensitivity testing of devices, whether performed using the HBM, MM or the CDM, provide ESD sensitivity levels for the comparison of one device to another using defined parameters. The ESD sensitivity of the device (defined in volts), as determined by using any of the defined models, may not be the actual failure voltage level in the manufacturing process or user environment. Table 4 provides a reference for various standards and test methods for ESD sensitivity testing. 1. Human Body Model Sensitivity A source of ESD damage is the charged human body, as modeled by HBM standards. This testing model represents the discharge from the fingertip of a standing individual delivered to the conductive leads of the device. It is modeled by a 100 pf capacitor discharged through a switching component and 1,500 ohm series resistor into the device under test. The discharge itself is a double exponential waveform with a rise time of 2-10 nanoseconds and a pulse duration of approximately 150 nanoseconds. The use of a 1,500 ohm series resistor means this model approximates a current source. All devices should be considered as HBM sensitive. The HBM ESD sensitivity of devices may be determined by testing the device using one of the referenced test methods. HBM sensitivities can be found in RAC VZAP, Qualified Manufacturers List of Products (QML-19500) or Qualified Manufacturer List (QML-38535). 2. Machine Model Sensitivity A source of damage for the MM is a rapid transfer of energy from a charged conductor to the conductive leads of the device. This ESD model is a 200 pf capacitor discharged through a 500 nh inductor directly into the device with no series resistor. Due to the lack of a series current limiting resistor, this model approximates a voltage source. In the real world this model represents a rapid discharge from items such as charged board assembly, charged cables or the conduction arm of an automatic tester. The discharge itself is a sinusoidal decaying waveform with a rise time of 5 to 8 nanoseconds and a period of approximately 80 nanoseconds. 3. Charged Device Model Sensitivity A source of damage for the CDM is the rapid discharge of energy from a charged device. The ESD event is totally device dependent, but its location relative to ground can influence the failure 9
16 level in the real world. The assumption for this test model is that the device itself has become charged and rapid discharge occurs when the charged device s conductive leads contact a conductive surface, which is at a lower potential. An issue with the preparation of a CDM test standard is the availability of suitable instrumentation to measure the discharge event. The waveform rise time is often less than 200 picoseconds. The entire event can take place in less than 2.0 nanoseconds. Although very short in duration, current levels can reach several tens of amperes during discharge. Table 4. ESD Susceptibility Test References for Devices ESD ESD Standards and Methods for Susceptibility Testing of Devices Model ANSI/ESD STM5.1 MIL-STD-883 Method 3015 HBM MIL-STD-750 Method 1020 MIL-PRF MIL-PRF MM CDM ANSI/ESD STM5.2 ANSI/ESD STM5.3.1 Assembly, Equipment and Design Hardening 1. Assembly, Equipment and Design Hardening Guidance Assemblies and equipment should have protective circuitry or techniques to meet the desired design goals. Determining the ESD susceptibility of assemblies and equipment may be based on simulation modeling, or actual testing. Table 5 provides a quick reference for various test methods associated with assembly and equipment susceptibility testing. 2. Direct Contact, Non-Operating Assembly, Body/Finger or Hand/Metal Tests This model can be used to verify that assemblies will not be damaged during non-operating conditions by direct contact to input, output and interface connections. This threat applies to all types of assemblies (see Table 5). 3. Direct Contact Operating Equipment Hand/Metal Test This model can be used to verify that operating equipment will not be damaged (or nonrecoverable faults will not be injected) by direct contact to operator accessible points and exposed surface areas during the normal maintenance process. This threat is limited to equipment subject to operator adjustments or maintenance activities during operation (see Table 5). 4. Indirect Contact, Operating Equipment Furniture Model Test This model can be used to verify that operating equipment in a home or office environment will not be damaged (or non-recoverable faults will not be injected) by indirect contact during normal activities performed within the proximity of the equipment. This threat applies to all electronic equipment in a home or office environment (see Table 5). 10
17 Table 5. ESD Susceptibility Test References for Assemblies and Equipment ESD Assembly / Equipment Model Body / Finger HBM Hand / Metal HBM Furniture Model ESD Test Standard or Method IEEE STD C62.38 (Sub-Assembly) IEC ANSI C63.16 (Equipment) ANSI C63.16 (Equipment) 11
18 (This annex is not part of ANSI/ESD S ) ANNEX C RELATED DOCUMENTS The following documents are listed for further reference. Some documents may be canceled. However, this listing provides a reference of documents reviewed during the preparation of this standard. Military / U.S. Government MIL-STD-3010, "Federal Test Method Standard" MIL-DTL-117, "Bags, Sleeves and Tubing Interior Packaging" MIL-PRF-81705, "Barrier Materials, Flexible, Electrostatic Free, Heat Sealable" MIL-E-17555, "Electronic and Electrical Equipment, Accessories, and Provisioned Items (Repair Parts): Packaging of" MIL-STD-1686, "Electrostatic Discharge Control Program for Protection of Electrical and Electronic Parts, Assemblies and Equipment (Excluding Electrically Initiated Explosive Devices)" MIL-HDBK-263, "Electrostatic Discharge Control Handbook for Protection of Electrical and Electronic Parts, Assemblies, and Equipment (Excluding Electrically-Initiated Explosive Devices)" MIL-M-38510, "General Specification for Military Microcircuits" MIL-P-82646, "Plastic Film, Conductive, Heat Sealable, Flexible" MIL-PRF-87893, Workstations, Electrostatic Discharge (ESD) Control MIL-STD-129, "Marking for Shipment and Storage" MIL-STD-1285, "Marking of Electrical and Electronic Parts" MMA , Revision 3, Standard Test Method for Evaluating Triboelectric Charge Generation and Decay 12
19 Industry Standards ANSI/IEEE-STD-142, "IEEE Green Book (IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems)" JESD 625A, "Requirements for Handling Electrostatic-Discharge-Sensitive (ESDS) Devices" EIA-583, Packaging Material Standards for Moisture Sensitive Items ESD-ADV3.2, Selection and Acceptance of Air Ionizers ESDSIL, "Reliability Analysis Center (RAC) ESD Sensitive Items List" EIA-471, Symbol and Label for Electrostatic Sensitive Devices EN , Protection of Electronic Devices from Electrostatic Phenomena General Requirements IEC , Protection of Electronic Devices from Electrostatic Phenomena General Requirements VZAP, Electrostatic Discharge Susceptibility Data 13
Example ESD Control Program Document Based on ANSI/ESD S20.20-2007
PROFESSIONAL STATIC CONTROL SERVICES Example ESD Control Program Document Based on ANSI/ESD S20.20-2007 The following document demonstrates the structure for an ESD control program that is compliant to
Test Reports with Ameriworx Conductive Vinyl Tile ANSI 20.20 2007 ANSI 20.20 2014 ESD S7.1 ESD STM97.1 ESD STM97.2
Test Reports with Ameriworx Conductive Vinyl Tile ANSI 20.20 2007 ANSI 20.20 2014 ESD S7.1 ESD STM97.1 ESD STM97.2 S20.20-2007 Approved February 11, 2007 ESD Association What was expected in 2007: Personnel
W ant to accomplish something
Fred Tenzer and Gene Felder, Desco Industries, Inc. ESD Control Program Periodic Verification Some practical advice for implementing ESD control periodic checks W ant to accomplish something important?
The Prevention and Control of Electrostatic Discharge (ESD) (AN-40-005)
(AN-40-005) An Introduction to ESD We experience occurrences of static electricity everyday. For example, walking along a carpeted floor in a heated room during winter generates sufficient static electricity
The Prevention and Control of Electrostatic Discharge (ESD) (AN-40-005)
(AN-40-005) An Introduction to ESD We experience occurrences of static electricity everyday. For example, walking along a carpeted floor in a heated room during winter generates sufficient static electricity
ACL 800 MEGOHMMETER OPERATION MANUAL
ACL 800 MEGOHMMETER OPERATION MANUAL Meter is warranted for one year from the date of purchase on parts and labor. Calibration is recommended every twelve months. NOTE: THIS MANUAL IS NOT TO BE SEPARATED
Automotive Electronics Council Component Technical Committee
AEC - Q101-005 - REV- ATTACHMENT 5 AEC - Q101-005 Rev- CAPACITIVE DISCHARGE MODEL (CDM) ELECTROSTATIC DISCHARGE (ESD) TEST METHOD - 005 DISCRETE COMPONENT CHARGED DEVICE MODEL (CDM) ELECTROSTATIC DISCHARGE
Use ESD Control Products Correctly Or You Can Do More Harm Than Good
www.conformity.com Use ESD Control Products Correctly Or You Can Do More Harm Than Good A Comprehensive Program Is Required For Effective ESD Control With most companies pressured by global competition,
ACL 395 Resistivity Meter
ACL 395 Resistivity Meter OPERATION MANUAL Meter is warranted for one year from the date of purchase on parts and labor. Calibration is recommended every 12 months. 840 W. 49 th Place Page 1 of 13 [email protected]
ANSI/IEC 60529-2004. Degrees of Protection Provided by Enclosures (IP Code) (identical national adoption)
ANSI Approval Date November 3, 2004 ANSI/IEC 60529-2004 Degrees of Protection Provided by Enclosures (IP Code) (identical national adoption) Published by: National Electrical Manufacturers Association
Guidelines how to set up an ESD Protected Area (EPA)
ImplementingESD safe materialsandproductsshouldbeperformedaccordinga specific logical ESD strategy. Without these specific ESD procedures it has little to no sense to install ESD safe products. Therefore
IEC 1000-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays
IEC 00-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays Application Note July 1999 AN9612.2 Author: Wayne Austin The SP720, SP721, SP723, and SP724 are protection
American National Standard for Electric Lamps Specifications for Performance of Self-ballasted Compact Fluorescent Lamps
Page 1 C78.5-2003 (R2008, R2015) American National Standard for Electric Lamps Specifications for Performance of Self-ballasted Compact Fluorescent Lamps Secretariat: National Electrical Manufacturers
CAN bus ESD protection diode
Rev. 04 15 February 2008 Product data sheet 1. Product profile 1.1 General description in a small SOT23 (TO-236AB) Surface-Mounted Device (SMD) plastic package designed to protect two automotive Controller
The 74LVC1G11 provides a single 3-input AND gate.
Rev. 8 17 September 2015 Product data sheet 1. General description The provides a single 3-input AND gate. The input can be driven from either 3.3 V or 5 V devices. This feature allows the use of this
American National Standard For Electrical Rigid Steel Conduit (ERSC)
Revision of ANSI C80.1-1994 American National Standard For Electrical Rigid Steel Conduit (ERSC) Secretariat: Approved August 18, 2005 American National Standards Institute, Inc. NOTICE AND DISCLAIMER
CHARLESWATER ESD AWARENESS BOOKLET
CHARLESWATER ESD AWARENESS BOOKLET PLEASE READ THOROUGHLY BEFORE WORKING ON OR HANDLING ESD SUSCEPTIBLE COMPONENTS OR ASSEMBLIES Use as part of Training Plan required by EN 61340-5-1 ESD CONTROL PROGRAMME
PESDxU1UT series. 1. Product profile. Ultra low capacitance ESD protection diode in SOT23 package. 1.1 General description. 1.
Rev. 02 20 August 2009 Product data sheet 1. Product profile 1.1 General description Ultra low capacitance ElectroStatic Discharge (ESD) protection diode in a SOT23 (TO-236AB) small SMD plastic package
ACL 600 Stati-Check Meter
ACL 600 Stati-Check Meter OPERATION MANUAL Meter is warranted for one year from the date of purchase on parts and labor. Calibration is recommended every twelve months. 840 W. 49 th Place Page 1 of 5 [email protected]
Tech Brief Surface Resistance Test Kit Operation and Maintenance
Tech Brief Surface Resistance Test Kit Operation and Maintenance Figure 1. Item 41290 Surface Resistance Test Kit Description The Surface Resistance Test Kit is a portable, accurate, and versatile instrument
Surface Mount Multilayer Ceramic Chip Capacitors for Automotive Applications
Surface Mount Multilayer Ceramic Chip Capacitors for Automotive Applications FEATURES AEC-Q200 qualified with PPAP available Available in 0402 to 1812 body size Three dielectric materials AgPd termination
4-bit binary full adder with fast carry CIN + (A1 + B1) + 2(A2 + B2) + 4(A3 + B3) + 8(A4 + B4) = = S1 + 2S2 + 4S3 + 8S4 + 16COUT
Rev. 03 11 November 2004 Product data sheet 1. General description 2. Features The is a high-speed Si-gate CMOS device and is pin compatible with low power Schottky TTL (LSTTL). The is specified in compliance
Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD)
Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Note: This guidance document is a translation of official Chinese document which is issued by CQC (China Quality Certification Center) on
Cable Discharge Event
Cable Discharge Event 1.0 Introduction The widespread use of electronic equipment in various environments exposes semiconductor devices to potentially destructive Electro Static Discharge (ESD). Semiconductor
Hex buffer with open-drain outputs
Rev. 5 27 October 20 Product data sheet. General description The provides six non-inverting buffers. The outputs are open-drain and can be connected to other open-drain outputs to implement active-low
SuperTan Extended (STE) Capacitors, Wet Tantalum Capacitors with Hermetic Seal
SuperTan Extended () Capacitors, Wet Tantalum Capacitors with Hermetic Seal FEATURES SuperTan Extended () represents a major breakthrough in wet tantalum capacitor Available technology. Its unique cathode
3-input EXCLUSIVE-OR gate. The 74LVC1G386 provides a 3-input EXCLUSIVE-OR function.
Rev. 02 3 September 2007 Product data sheet 1. General description The provides a 3-input EXCLUSIVE-OR function. The input can be driven from either 3.3 or 5 V devices. This feature allows the use of these
SMS7630-061: Surface Mount, 0201 Zero Bias Silicon Schottky Detector Diode
DATA SHEET SMS7630-061: Surface Mount, 0201 Zero Bias Silicon Schottky Detector Diode Applications Sensitive RF and microwave detector circuits Sampling and mixer circuits High volume wireless systems
Current Probes. User Manual
Current Probes User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall
CLA4607-085LF: Surface Mount Limiter Diode
DATA SHEET CLA4607-085LF: Surface Mount Limiter Diode Applications Low-loss, high-power limiters Receiver protectors Anode (Pin 1) Anode (Pin 3) Features Low thermal resistance: 55 C/W Typical threshold
SiGe:C Low Noise High Linearity Amplifier
Rev. 2 21 February 2012 Product data sheet 1. Product profile 1.1 General description The is a low noise high linearity amplifier for wireless infrastructure applications. The LNA has a high input and
LIN-bus ESD protection diode
Rev. 3 31 May 2011 Product data sheet 1. Product profile 1.1 General description in a very small SOD323 (SC-76) Surface-Mounted Device (SMD) plastic package designed to protect one automotive Local Interconnect
APPLICATION NOTES FOR SMD LEDs
Storage conditions SMD devices are usually moisture/reflow sensitive. Moisture from atmospheric humidity enters permeable packaging materials by diffusion. Assembly processed used to solder SMD packages
74HC02; 74HCT02. 1. General description. 2. Features and benefits. Ordering information. Quad 2-input NOR gate
Rev. 5 26 November 2015 Product data sheet 1. General description 2. Features and benefits The is a quad 2-input NOR gate. Inputs include clamp diodes. This enables the use of current limiting resistors
SC Series: MIS Chip Capacitors
DATA SHEET SC Series: MIS Chip Capacitors Applications Systems requiring DC blocking or RF bypassing Fixed capacitance tuning element in filters, oscillators, and matching networks Features Readily available
ESD/EOS 6 6.1 ESD. 6.1.1 Electrostatic Discharge (ESD) 6.1.2 Why Should I Care About Electrostatic Discharge?
6 6.1 ESD 6.1.1 Electrostatic Discharge (ESD) Electrostatic discharge (ESD) costs the electronics industry millions of dollars each year in damaged components, non-functional circuit boards and scrambled
Signal Conditioning Piezoelectric Sensors
Application Report SLOA033A - September 2000 Signal Conditioning Piezoelectric Sensors James Karki Mixed Signal Products ABSTRACT Piezoelectric elements are used to construct transducers for a vast number
HEF4011B. 1. General description. 2. Features and benefits. 3. Ordering information. 4. Functional diagram. Quad 2-input NAND gate
Rev. 6 10 December 2015 Product data sheet 1. General description 2. Features and benefits 3. Ordering information The is a quad 2-input NAND gate. The outputs are fully buffered for the highest noise
74HC2G02; 74HCT2G02. 1. General description. 2. Features and benefits. 3. Ordering information. Dual 2-input NOR gate
Rev. 5 27 September 2013 Product data sheet 1. General description 2. Features and benefits 3. Ordering information The is a dual 2-input NOR gate. Inputs include clamp diodes. This enables the use of
INTERNATIONAL STANDARD
IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60
CLA Series: Silicon Limiter Diode Bondable Chips
DATA SHEET CLA Series: Silicon Limiter Diode Bondable Chips Applications LNA receiver protection Commercial and defense radar Features Established Skyworks limiter diode process High-power, mid-range,
74HC154; 74HCT154. 4-to-16 line decoder/demultiplexer
Rev. 7 29 February 2016 Product data sheet 1. General description 2. Features and benefits 3. Ordering information The is a. It decodes four binary weighted address inputs (A0 to A3) to sixteen mutually
Description. Table 1. Device summary. Order code Temperature range Package Packaging Marking
14-stage ripple carry binary counter/divider and oscillator Applications Automotive Industrial Computer Consumer Description Datasheet - production data Features Medium speed operation Common reset Fully
LC03-6R2G. Low Capacitance Surface Mount TVS for High-Speed Data Interfaces. SO-8 LOW CAPACITANCE VOLTAGE SUPPRESSOR 2 kw PEAK POWER 6 VOLTS
Low Capacitance Surface Mount TVS for High-Speed Data terfaces The LC3- transient voltage suppressor is designed to protect equipment attached to high speed communication lines from ESD, EFT, and lighting.
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 46 2007. Test Method for AC to DC Power Supplies
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 46 2007 Test Method for AC to DC Power Supplies NOTICE The Society of Cable Telecommunications Engineers (SCTE)
AN11243. Failure signature of electrical overstress on power MOSFETs. Document information
Rev. 01 29 October 2012 Application note Document information Info Keywords Abstract Content Power MOSFETs, Electrical Overstress (EOS), Unclamped Inductive Switching (UIS) When Power MOSFETs fail, there
Features. Symbol JEDEC TO-220AB
Data Sheet June 1999 File Number 2253.2 3A, 5V,.4 Ohm, N-Channel Power MOSFET This is an N-Channel enhancement mode silicon gate power field effect transistor designed for applications such as switching
Planar PIN diode in a SOD323 very small plastic SMD package.
Rev. 8 12 May 2015 Product data sheet 1. Product profile 1.1 General description Planar PIN diode in a SOD323 very small plastic SMD package. 1.2 Features and benefits High voltage, current controlled
Product Overview 2Pro AC Devices Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications
Product Overview Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications The 2Pro AC family of devices provide integrated overcurrent/overvoltage/ overtemperature
CHECKING AND TESTING ELECTRICAL INSTALLING WORK
CHECKING AND TESTING ELECTRICAL INSTALLING WORK Department of Consumer and Employment Protection Energy Safety Preface It is a requirement of the Electricity (Licensing) Regulations 1991 that all electrical
74HCU04. 1. General description. 2. Features and benefits. 3. Ordering information. Hex unbuffered inverter
Rev. 7 8 December 2015 Product data sheet 1. General description The is a hex unbuffered inverter. Inputs include clamp diodes. This enables the use of current limiting resistors to interface inputs to
IP4234CZ6. 1. Product profile. Single USB 2.0 ESD protection to IEC 61000-4-2 level 4. 1.1 General description. 1.2 Features. 1.
Rev. 01 16 April 2009 Product data sheet 1. Product profile 1.1 General description The is designed to protect Input/Output (I/O) USB 2.0 ports, that are sensitive to capacitive loads, from being damaged
1SMB59xxBT3G Series, SZ1SMB59xxT3G Series. 3 Watt Plastic Surface Mount Zener Voltage Regulators
9xxBTG Series, SZ9xxTG Series Watt Plastic Surface Mount Zener Voltage Regulators This complete new line of W Zener diodes offers the following advantages. Features Zener Voltage Range. V to V ESD Rating
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
Introduction to Data Centre Design
Introduction to Data Centre Design Barry Elliott BSc RCDD MBA CEng Earthing, grounding and bonding November 09 Earthing what s the point Safety from electrical hazards Reliable signal reference within
Surface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications
Surface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications ELECTRICAL SPECIFICATIONS X7R GENERAL SPECIFICATION Note Electrical characteristics at +25 C unless otherwise specified
American National Standard For Electric Power Systems and Equipment Voltage Ratings (60 Hertz)
Revision of ANSI C84.1-2006 American National Standard For Electric Power Systems and Equipment Voltage Ratings (60 Hertz) Secretariat: National Electrical Manufacturers Association Approved December 6,
TS555. Low-power single CMOS timer. Description. Features. The TS555 is a single CMOS timer with very low consumption:
Low-power single CMOS timer Description Datasheet - production data The TS555 is a single CMOS timer with very low consumption: Features SO8 (plastic micropackage) Pin connections (top view) (I cc(typ)
3M Wrist Strap and Footwear Tester 740. User s Guide
3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6
EPM3. Phase Sequence and Motor Rotation Tester. Users Manual
EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR
74HC238; 74HCT238. 3-to-8 line decoder/demultiplexer
Rev. 4 27 January 2016 Product data sheet 1. General description 2. Features and benefits 3. Ordering information The decodes three binary weighted address inputs (A0, A1 and A2) to eight mutually exclusive
Pulse Proof, High Power Thick Film Chip Resistors
Pulse Proof, High Power Thick Film Chip Resistors STANDARD ELTRICAL SPIFICATIONS MODEL CASE SIZE INCH CASE SIZE METRIC POWER RATING P 70 W LIMITING ELEMENT VOLTAGE U max. AC/DC -HP e3 FTURES Excellent
Optocoupler, Phototransistor Output, Dual Channel, SOIC-8 Package
ILD25T, ILD26T, ILD27T, ILD211T, ILD213T Optocoupler, Phototransistor Output, Dual Channel, SOIC-8 Package i17925 A1 C2 A3 C4 i17918-2 8C 7E 6C 5E DESCRIPTION The ILD25T, ILD26T, ILD27T, ILD211T, and ILD213T
74HC377; 74HCT377. 1. General description. 2. Features and benefits. 3. Ordering information
Rev. 4 24 February 2016 Product data sheet 1. General description 2. Features and benefits 3. Ordering information The is an octal positive-edge triggered D-type flip-flop. The device features clock (CP)
Thick Film Resistor Networks, Dual-In-Line, Molded DIP
Thick Film Resistor Networks, Dual-In-Line, Molded DIP FEATURES Isolated, bussed, and dual terminator schematics available 0.160" (4.06 mm) maximum seated height and rugged, molded case construction Thick
TPN4R712MD TPN4R712MD. 1. Applications. 2. Features. 3. Packaging and Internal Circuit. 2014-12 2015-04-21 Rev.4.0. Silicon P-Channel MOS (U-MOS )
MOSFETs Silicon P-Channel MOS (U-MOS) TPN4R712MD TPN4R712MD 1. Applications Lithium-Ion Secondary Batteries Power Management Switches 2. Features (1) Low drain-source on-resistance: R DS(ON) = 3.8 mω (typ.)
DISCRETE SEMICONDUCTORS DATA SHEET. BT151 series C Thyristors
DISCRETE SEMICONDUCTORS DATA SHEET Product specification April 24 Product specification GENERAL DESCRIPTION QUICK REFERENCE DATA Passivated thyristors in a plastic SYMBOL PARAMETER MAX. MAX. MAX. UNIT
NEMA ICS 61131-1-2005 (R2013) Programmable Controllers Part 1: General Information
NEMA ICS 61131-1-2005 (R2013) IEC Publication 61131-1 Programmable Controllers Part 1: General Information Published by: National Electrical Manufacturers Association 1300 North 17 th Street, Suite 900
American National Standard. For Insulators. Wet Process Porcelain and Toughened Glass Suspension Type ANSI/NEMA C29.2-2012
ANSI/NEMA C29.2-2012 American National Standard For Insulators Wet Process Porcelain and Toughened Glass Suspension Type Secretariat: National Electrical Manufacturers Association Approved: October 2012
Quad 2-input NAND Schmitt trigger
Rev. 9 15 December 2015 Product data sheet 1. General description 2. Features and benefits 3. Applications The is a quad two-input NAND gate. Each input has a Schmitt trigger circuit. The gate switches
AN3353 Application note
Application note IEC 61000-4-2 standard testing Introduction This Application note is addressed to technical engineers and designers to explain how STMicroelectronics protection devices are tested according
3-to-8 line decoder, demultiplexer with address latches
Rev. 7 29 January 2016 Product data sheet 1. General description The is a high-speed Si-gate CMOS device and is pin compatible with low-power Schottky TTL (LSTTL). The is specified in compliance with JEDEC
Femtofarad bidirectional ESD protection diode
Rev. 3 24 October 2011 Product data sheet 1. Product profile 1.1 General description Femtofarad bidirectional ElectroStatic Discharge (ESD) protection diode in a leadless ultra small SOD882 Surface-Mounted
Guide to the electrical parameter classifications of IEC 60950 and IEC 62368 safety standards
Guide to the electrical parameter classifications of IEC 60950 and IEC 62368 safety standards Abstract This Guide is an informative listing of selected terms and definitions found in IEC Glossary entry
Low-power configurable multiple function gate
Rev. 7 10 September 2014 Product data sheet 1. General description The provides configurable multiple functions. The output state is determined by eight patterns of 3-bit input. The user can choose the
Diode Circuits. Operating in the Reverse Breakdown region. (Zener Diode)
Diode Circuits Operating in the Reverse Breakdown region. (Zener Diode) In may applications, operation in the reverse breakdown region is highly desirable. The reverse breakdown voltage is relatively insensitive
USB-ISO - USB 2.0 compliant, 1000VDC USB Full Speed isolator Users Manual
USB-ISO - USB 2.0 compliant, 1000VDC USB Full Speed isolator Users Manual All boards produced by Olimex are ROHS compliant Rev. D, July 2011 Copyright(c) 2011, OLIMEX Ltd, All rights reserved Page1 INTRODUCTION
EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec.
EMC STANDARDS The EMC standards that a particular electronic product must meet depend on the product application (commercial or military) and the country in which the product is to be used. These EMC regulatory
BLL6G1214L-250. 1. Product profile. LDMOS L-band radar power transistor. 1.1 General description. 1.2 Features and benefits. 1.
BLL6G1214L-25 Rev. 1 16 February 212 Preliminary data sheet 1. Product profile 1.1 General description 25 W LDMOS power transistor intended for L-band radar applications in the 1.2 GHz to 1.4 GHz range.
8-bit binary counter with output register; 3-state
Rev. 3 24 February 2016 Product data sheet 1. General description The is an 8-bit binary counter with a storage register and 3-state outputs. The storage register has parallel (Q0 to Q7) outputs. The binary
PRTR5V0U2F; PRTR5V0U2K
Rev. 02 19 February 2009 Product data sheet 1. Product profile 1.1 General description Ultra low capacitance double rail-to-rail ElectroStatic Discharge (ESD) protection devices in leadless ultra small
The 74LVC1G04 provides one inverting buffer.
Rev. 12 6 ugust 2012 Product data sheet 1. General description The provides one inverting buffer. Input can be driven from either 3.3 V or 5 V devices. These features allow the use of these devices in
LUXEON LEDs. Circuit Design and Layout Practices to Minimize Electrical Stress. Introduction. Scope LED PORTFOLIO
LED PORTFOLIO LUXEON LEDs Circuit Design and Layout Practices to Minimize Electrical Stress Introduction LED circuits operating in the real world can be subjected to various abnormal electrical overstress
74HC4040; 74HCT4040. 12-stage binary ripple counter
Rev. 5 3 February 2016 Product data sheet 1. General description 2. Features and benefits 3. Applications 4. Ordering information The is a with a clock input (CP), an overriding asynchronous master reset
Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content
Charged cable event David Pommerenke, [email protected], 916 785 4550 Last update: Feb.23, 2001 Content Goal Energy sources, which may lead to CDE. Complexity of the different discharge modes. Possible
Selection Guide for Conversion of Carbon Composition Resistors
Selection Guide for Conversion of Carbon Composition Resistors believes that the information described in this publication is accurate and reliable, and much care has been taken in its preparation. However,
Design Guide for the Control of ESD in the esata Interface
Design Guide for the Control of ESD in the esata Interface Pat Young Principal Engineer Silicon Image, Steelvine Storage Products Scope This document is an informative design guideline only. It is intended
Thick Film Resistor Networks, Military, MIL-PRF-83401 Qualified, Type RZ010 and RZ020 Dual-In-Line, Molded DIP
MDM (Military M831/1 and /2) Thick Film Resistor Networks, Military, MIL-PRF-831 Qualified, Type RZ1 and RZ2 Dual-In-Line, Molded DIP STANDARD ELECTRICAL SPECIFICATIONS VISHAY DALE MODEL/ PIN NO. MIL STYLE
Evaluating Water-Damaged Electrical Equipment
Evaluating Water-Damaged Electrical Equipment 1 USE OF THIS PUBLICATION This publication provides information on how to evaluate electrical equipment that has been exposed to water through flooding, fire
Passivated, sensitive gate triacs in a SOT54 plastic package. General purpose switching and phase control
TO-92 Rev. 9 9 November 2 Product data sheet. Product profile. General description Passivated, sensitive gate triacs in a SOT54 plastic package.2 Features and benefits Designed to be interfaced directly
Optocoupler, Photodarlington Output, Dual Channel, SOIC-8 Package
Optocoupler, Photodarlington Output, i179042 DESCRIPTION A1 C 2 A3 C4 8 C 7E 6C 5E The ILD233T is a high current transfer ratio (CTR) optocoupler. It has a gallium arsenide infrared LED emitter and silicon
Dielectric Withstand Testing in a Production Environment
Dielectric Withstand Testing in a Production Environment Performing a routine product safety test should not in itself represent a shock hazard to the operator who is conducting the test, yet anytime you
VERIFICATION OF ESD ENVIRONMENT IN PRODUCTION PHILOSOPHY, METHODOLOGY AND TOOLS
VERIFICATION OF ESD ENVIRONMENT IN PRODUCTION Credence Technologies PHILOSOPHY, METHODOLOGY AND TOOLS Vladimir Kraz Credence Technologies, Inc. 1 Company Overview Credence Technologies designs and manufactures
Evaluating Water-Damaged Electrical Equipment
Evaluating Water-Damaged Electrical Equipment 1 USE OF THIS PUBLICATION This publication provides information on how to evaluate electrical equipment that has been exposed to water through flooding, fire
SSM3K335R SSM3K335R. 1. Applications. 2. Features. 3. Packaging and Pin Configuration. 2012-07-19 Rev.3.0. Silicon N-Channel MOS (U-MOS -H)
MOSFETs Silicon N-Channel MOS (U-MOS-H) SSM3K335R SSM3K335R 1. Applications Power Management Switches DC-DC Converters 2. Features (1) 4.5-V gate drive voltage. (2) Low drain-source on-resistance : R DS(ON)
Portable Holiday Detectors
PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors Pipeline Inspection Co. Shipping Address: 1919 Antoine Houston, Texas 77055 www.picltd.com Tel: 713/681-5837 Fax: 713/681-4838 E-mail: [email protected]
ESDLIN1524BJ. Transil, transient voltage surge suppressor diode for ESD protection. Features. Description SOD323
Transil, transient voltage surge suppressor diode for ESD protection Datasheet production data Features Max peak pulse power 160 W (8/0 µs) Asymmetrical bidirectional device Stand-off voltage: 15 and 4
OLF500: High CMR, High-Speed Logic Gate Hermetic Surface Mount Optocoupler
TM DATA SHEET OLF500: High CMR, High-Speed Logic Gate Hermetic Surface Mount Optocoupler Features Hermetic SMT flat-pack package Electrical parameters guaranteed over 55 C to +125 C ambient temperature
MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.
MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question. 1) If the voltage at a point in space is zero, then the electric field must be A) zero. B) positive.