ISO 13485:201x What is in the new standard?
|
|
|
- Brendan McDonald
- 9 years ago
- Views:
Transcription
1 ISO 13485:201x What is in the new standard? Eric Finegan, Quality Mgr, BTE Technologies, Inc
2 Presentation Slides This slide deck is the presentation performed on A more detailed slide deck will be posted with expanded information in a number of the slides, and additional references and resources added within the next few weeks. Please check back on the ASQ Baltimore website for the expanded version Alternatively, to get a notice when the slide deck is posted. 2
3 ISO What is ISO 13485? ISO 13485:2003 specifies requirements for a quality management system where an organization needs to demonstrate its ability to provide medical devices and related services that consistently meet customer requirements and regulatory requirements applicable to medical devices and related services. (ISO) 3
4 ISO What is ISO 13485? The primary objective of ISO 13485:2003 is to facilitate harmonized medical device regulatory requirements for quality management systems. As a result, it includes some particular requirements for medical devices and excludes some of the requirements of ISO 9001 that are not appropriate as regulatory requirements. (ISO) 4
5 ISO Who is working on ISO 13485? ISO 13485:2003 is being developed by ISO Technical Committee 210 Working Group 1 (ISO TC 210 WG1). Standards work is not as public as the ISO 9001 work that is on-going. 5
6 ISO vs ISO 9001 Comparisons are performed on the current standards ISO 13485:2003 (unchanged in 12 years). ISO 9001:2008 (about to change). New ISO will NOT align with the new ISO High Level Structure ISO still mimics the sections 4, 5, 6, 7, 8 of the current ISO 9001 standard. 6
7 ISO vs ISO 9001 Clause structure (old vs new) New clauses (Annex SL of ISO 9001:2015) 1 Scope 2 Normative Reference 3 Terms and Definitions 4 Context of the Organization 5 Leadership 6 Planning 7 Support 8 Operation 9 Performance evaluation 10 Improvement Existing clauses (ISO 13485:2003/201x) 1 Scope 2 Normative Reference 3 Terms and Definitions 4 Quality management system 5 Management responsibility 6 Resource management 7 Product realization 8 Measurement, analysis and improvement 7
8 ISO vs ISO 9001 Due to regulatory focus, there are more requirements specified within ISO Rather than leave it to the manufacturer to determine the need for a documented procedure or a record, ISO details required documents/records. 8
9 ISO vs ISO 9001 Documentation requirements (ISO 9001): Documents needed by the organization to ensure the effective planning, operation and control of its processes. Procedures that are required are:» Document Control (4.2.3)» Records (4.2.4)» Internal Audits (8.2.2)» Control of Nonconforming Product (8.3)» Corrective Action (8.5.2)» Preventive Action (8.5.3) 9
10 ISO vs ISO 9001 Documentation requirements (ISO 13485): 31 Documents required are called out specifically. Document Control (4.2.3) Records (4.2.4) Risk Management (7.1) Design and development (7.3.1) Purchasing process (7.4.1) Product identification ( ) Product return identification from normal production ( ) Product traceability ( ) Product Conformity preservation (7.5.5) Control of monitoring and measuring equipment (7.6) Feedback system (including customer complaint) (8.2.1) Internal Audits (8.2.2) Monitoring and measurement of product ( ) Control of Nonconforming Product (8.3) Analysis of data (8.4) Advisory notice (8.5.1) Vigilance system (8.5.1) Corrective Action (8.5.2) Preventive Action (8.5.3) Maintenance Activities (6.3) Health, cleanliness and clothing (6.4) Work environment conditions, monitoring and control (6.4) Control of contaminated products (6.4) Control of production and service provision ( ) Product cleanliness ( ) Installation activities ( ) Servicing activities ( ) Validation of the application of the computer S/W ( ) Sterilization process validation ( ) Control of limited shelf life products (7.5.5) Post-production phase experience (8.2.1) 10
11 ISO vs ISO 9001 Record requirements: Records determined by the organization to be necessary to ensure effective planning, operation and control of processes. ISO 9001 requires specifically 20 records if created in the course of producing product. ISO requires specifically 37 records if created in the course of producing product. 11
12 ISO vs ISO 9001 Most differences between the two standards are clarifications due to documentation requirements: The organization shall identify vs The organization shall determine where applicable defined and documented 12
13 ISO vs ISO 9001 Other than minor clarifications of text and regulatoryspecific changes, the following items are different: Maintaining effectiveness of the system versus Continual improvement Replace Customer Satisfaction with Regulatory requirements Work environment requirements are expanded Verification, validation, design output and design transfer more detailed Risk management is addressed Complaint management is addressed 13
14 ISO 13485:2016 What s New? Many additions. Some new requirements. Some expansion / clarification. Increased clarification of interrelationship between clauses and requirements. 14
15 ISO 13485:2016 What s New? Increase in Regulatory requirements Makes sense, standard revolves around a regulatory framework. Regulatory / regulations are mentioned 16 times in ISO 13485:2003. Terms are mentioned at least 80 times in latest draft. 15
16 ISO 13485:2016 What s New? Expansion of Scope Moving from Medical Device manufacturers to organizations involved in any aspect of the product life-cycle (from design through distribution and support) 16
17 ISO 13485:2016 What s New? Note that the content of the changes in the clauses throughout the remainder of the presentation are based on documents that are still being reviewed and updated by TC210/WG1, so these requirements may be changed prior to the publication of the (proposed) ISO 13485:2016 standard. 17
18 General Requirements Changes Clause 4.1 General Requirements Role(s) undertaken by organization under regulatory requirements are now required to be documented In addition to The organization shall ensure the availability of resources Calls out using a risk based approach for developing QMS processes. Anything that affects the quality system needs to be viewed from that risk perspective (and documented) 18
19 General Requirements Changes Clause 4.1 General Requirements Records to meet regulatory requirements specified more detailed than existing Control of outsourced processes based on risk and ability. beyond Control of such outsourced processes shall be identified within the quality management system 19
20 General Requirements Changes Clause 4.1 General Requirements Requirement to validate the computer software used for QMS prior to initial use and after changes Expansion of (validation of the application of computer software) Called out specifically by the FDA in 21 CFR (i); Software used for, but not limited to, product design, testing, production, labeling, distribution, inventory control, data management, complaint handling, equipment calibration and maintenance, and corrective and preventive action. If software involves or affects the quality system, you need to validate it. 20
21 General Requirements Changes Clause 4.2 Documentation Requirements Detailed list of documented items that can be included in a product or technical file to meet regulatory requirements Useful checklist, but since each technical file is different for each market, will never be able to be comprehensive Existing standard states any other documentation specified by national or regional regulations May have been more useful in an Annex, easily updated in future, but that is not how the committee decided to go Good example of the new standard s style to be more prescriptive 21
22 General Requirements Changes Record Requirements Unfortunately doesn t specifically address record retention, so regulatory / quality / documentation personnel will still need to make themselves aware of the various international retention requirements. 22
23 Management Responsibility Changes General Requirements Regulatory requirements are addressed throughout the standard, rather than trickle down through Sections 4 and 5 23
24 Management Responsibility Changes Clause QMS planning A note is to be added clarifying what quality systems planning normally includes quality objectives should be consistent with be quality policy, action items to accomplish objectives, monitor progress, and revisions There has been some debate as to whether an actual plan document is required FDA requires establish a Quality plan versus ensure the planning of the quality management system 24
25 Management Responsibility Changes Clause Responsibility and authority Responsibilities and authorities for regulatory requirements are being specified. how specific individuals are nominated as responsible for activities having to do with monitoring of the product, and also for post-production activities competency of regulatory and quality personnel to be defined 25
26 Management Responsibility Changes Clause Management representative Focus on documentation of the quality management system and the removal of customer requirements from bullet c) Regulatory bodies are concerned with safe and effective devices, not customer requirements promotion of awareness of regulatory and customer requirements to promotion of awareness of regulatory requirements 26
27 Management Responsibility Changes Clause 5.6 Management review Organization to record rationale for frequency for management review Justification required moving forward Improvement clarified for new or revised regulatory requirements Management review outputs changed from improvement needed to maintain the effectiveness of the quality management system and its processes to improvement needed to maintain the suitability and adequacy of the quality management system and its processes 27
28 Resource Management Changes Clause Human resources General Personnel requirements defined at all levels across product, process, regulatory requirements and QMS Personnel who are involved with fulfilling process requirements, regulatory requirements, and quality system compliance Will require the organization to define what education, skills, and training those individuals need to have to perform each role More prescriptive than Personnel performing work affecting product quality shall be competent on the basis of appropriate education, training, skills and experience 28
29 Resource Management Changes Clause Competence, awareness and training New standard requires personnel to maintain competency detailed requirements and risk evaluation of training effectiveness to be provided effectiveness of the training is to be commensurate with the risks associated with the work that an individual is performing controversial, as still relatively subjective 29
30 Resource Management Changes Clause 6.3 Infrastructure Documented procedures for production and any controlled work environment are required. Maintenance requirements to be implemented how those activities are being performed, planned intervals for maintenance how records associated with how those activities are being maintained Information systems are now included (exist in ISO 9001, but not in current ISO 13485). 30
31 Resource Management Changes Clause 6.4 Work environment Significant additional detail to clarify requirements to work environment will help to reduce auditor subjectivity conditions to be considered such as noise, temperature, humidity, lighting, or weather areas of infrastructure such as inspection areas, storage areas, and distribution areas, and any other area involved with product manufacture New section added (6.4.2) that will address particular requirements for sterile medical devices (special work environment case) 31
32 Product Realization Changes Clause 7.1 Planning of product realization Greater focus on risk management Requires planning and risk management incorporation for verification, validation, revalidation, monitoring, measurement, inspection, test activities, handling, storage, and traceability Note added for organizations to look at IEC/ISO (software lifecycle processes) 32
33 Product Realization Changes Clause 7.2 Customer-related processes User training to ensure that the product will be used in a safe and effective manner now required Organizations must protect confidential health information from their customers however received (customer requirements, customer servicing, post-market surveillance) 33
34 Product Realization Changes New clause Communication with regulatory authorities Under current Customer communication As appropriate, the organization shall communicate with regulatory authorities in accordance with planned arrangements. product information, regulatory inquiries, complaints, and advisory notices documented procedure will be required 34
35 Product Realization Changes Clause Design and development planning Previous version required planning, now organizations will be required to document planning and results Design traceability from inputs through outputs required 35
36 Product Realization Changes Clauses Design and development verification Design and development validation More emphasis on planning design and development verification and validation activities documented methods, acceptance criteria and sample sizes that you will utilize, along with the rationale behind selecting them Validation on production units or (documented) equivalents Added to match FDA requirement 21 CFR 820(g) Design validation shall be performed under defined operating conditions on initial production units, lots, or batches, or their equivalents 36
37 Product Realization Changes Clause Design and development transfer New clause requiring a documented plan if you are going to transfer your design to another facility or an outsourcing partner ensure that your design and development outputs are suitable for production Aspects the organization should consider supplier quality and capability, manufacturing personnel capability and training, manufacturing process and process validation, materials, manufacturing tools and method, manufacturing environment, installation, and service. New emphasis on supplier control for design transfer 37
38 Product Realization Changes Clause Design and development records New clause that defines the records that are to be clearly identified and maintained in the design and development file. more prescriptive as to the types of documentation (align with FDA/EU) Examples include (as appropriate):» Results of preclinical tests, biocompatibility studies, clinical evaluation» Postmarket clinical follow-up plan and evaluation report» Electrical safety and electromagnetic compatibility» Software verification and validation 38
39 Product Realization Changes Clause 7.4 Purchasing Emphasis on risk analysis. Clause broken out and documentation requirements clarified Supplier approval Monitoring of suppliers Supplier documentation Criteria for selection, evaluation and re-evaluation consistent with risk, along with evidence of review 39
40 Product Realization Changes Clause Purchasing information Purchasing information to include, where possible, suppliers agreement to notify the organization of any changes Align with FDA 21 CFR (b) Purchasing documents shall include, where possible, an agreement that the suppliers, contractors, and consultants agree to notify the manufacturer of changes in the product or service so that manufacturers may determine whether the changes may affect the quality of a finished device. 40
41 Product Realization Changes Clause Verification of purchased product Clause updated to add that the extent of verification must be commensurate with product risks and the result of evaluation and re-evaluation are to be documented 41
42 Product Realization Changes Clause Validation of processes for production and service provision Validate processes for production and service provision where output cannot be or is not verified Required to document validation plans and procedures, including procedures for validation of sterilization and packaging processes 42
43 Product Realization Changes Clause Identification and traceability Unique device identification (UDI) where required by national or regional regulations will need to be performed Requirement added for procedures for separation of returned products from conforming products 43
44 Product Realization Changes Clause Customer Property Customer property can include intellectual property or confidential health information, based on the regulatory requirements of the market the device is sold into. 44
45 Product Realization Changes Clause Preservation of product Organization needs to evaluate packaging and shipping containers to ensure they are designed to protect the device from contamination and during the processing, handling, storage, and distribution A note is added that sterile barrier systems of sterile medical devices are a constituent part of a medical device. A new clause ( ) Particular requirements for sterile medical devices has been added. 45
46 Measurement/Analysis/Improvement Changes Clause 8.2 Monitoring and measurement Documented processes for gathering data from production and post-production activities are now required. Trending data based on this review will be required to be reviewed, analyzed and determine if applicable to enter CAPA process. This data is now required to become an input to the organization s risk management program. 46
47 Measurement/Analysis/Improvement Changes Clause Complaint Handling A new clause that requires procedures for complaint handling, investigation, regulatory notification and how this information relates to other processes within the QMS Aligns with the FDA 21 CFR , Complaint files 47
48 Measurement/Analysis/Improvement Changes Clause Reporting A new clause that requires procedures and records for reporting to regulatory authorities documents explicitly what has been assumed under
49 Measurement/Analysis/Improvement Changes Clause Monitoring and measurement of product This section now includes a note that says, "Records shall identify the test equipment used to perform measurement activities and the person(s) authorizing release of product." This applies traceability to the test equipment used during release 49
50 Measurement/Analysis/Improvement Changes Clause 8.3 Control of nonconforming product Non-conforming product shall be considered for corrective action. Records associated with nonconforming product management are required. Section 8.3 has been broken down in several different subsections Control of nonconforming product (general) Actions in response to nonconforming product before delivery Actions in response to nonconforming product after delivery Rework 50
51 Measurement/Analysis/Improvement Changes Clause Corrective action Additional requirement to plan corrective actions commensurate with risk (device safety and performance) 51
52 Measurement/Analysis/Improvement Changes Clause Preventive action Preventive actions are to be reviewed in a timely manner. When addressing preventive actions, the impact to the QMS and the organization s regulatory requirements ISO is still going to call out preventive action, rather than incorporating it as risk-based thinking throughout the standard (as done in ISO 9001:2015) One of the reasons is that the FDA QSR specifically requires preventive action as part of the organization s CAPA process 52
53 ISO 13485:2016 Changes Although a significant set of changes, most of them are clarifications of the existing standard (against existing regulations) Regulatory requirements. Risk Management (not simply risk-based thinking). Verification, Validation and Transfer activities defined. Improved supplier control. 53
54 ISO 13485:2016 Changes For manufacturers who have medical devices in international markets, these should not be significant changes Audits will be clearer for both auditor and auditee, with less interpretation of the deliverables (especially for regulatory requirements). Suppliers of medical devices will now have a standard that is clearer for what is expected of them. Not every supplier will be required to follow every requirement. 54
55 Standards News ISO 9001 ISO ISO 9001:2015 projected to be release this month. ISO 14001:2015 projected to be released soon. ISO 13485:201x FDIS Scheduled to be released after the August 2015 meeting, but information is showing that one more meeting may be necessary due to the number of comments to be addressed. 55
56 Questions? Thank you 56
57 ISO 13485:2003 vs EN ISO 13485:2012 EN ISO 13485:2012 Not a new version of ISO European harmonized standard Adds interpretative Annexes at the end of the standard to allow mapping to the Medical Devices Directive and the European interpretation of how the standard is to be used Only applies to manufacturers who wish to place medical devices on the EU market 57
ISO 9001:2000 AUDIT CHECKLIST
ISO 9001:2000 AUDIT CHECKLIST No. Question Proc. Ref. Comments 4 Quality Management System 4.1 General Requirements 1 Has the organization established, documented, implemented and maintained a quality
ISO 9001:2000 Gap Analysis Checklist
ISO 9001:2000 Gap Analysis Checklist Type: Assessor: ISO 9001 REQUIREMENTS STATUS ACTION/COMMENTS 4 Quality Management System 4.1 General Requirements Processes needed for the quality management system
Internal Quality Management System Audit Checklist (ISO9001:2015) Q# ISO 9001:2015 Clause Audit Question Audit Evidence 4 Context of the Organization
Internal Quality Management System Audit Checklist (ISO9001:2015) Q# ISO 9001:2015 Clause Audit Question Audit Evidence 4 Context of the Organization 4.1 Understanding the organization and its context
ISO-9001:2000 Quality Management Systems
ISO-9001:2000 Quality Management Systems REQUIREMENTS 10/10/2003 ISO-9001:2000 Requirements 1 Process Based Approach C U S MANAGEMENT RESPONSIBILITY RESOURCE MANAGEMENT C U S T O M Requirements PRODUCT
ISO 9001 : 2008 QUALITY MANAGEMENT SYSTEM AUDIT CHECK LIST INTRODUCTION
INTRODUCTION What auditors should look for: the items listed in these headings that the ISO requirement is met that the requirement is met in the manner described in the organization's documentation Page
Revision Date Author Description of change. 10 07Jun13 Mark Benton Removed Admin. Manager from approval
Page 2 of 15 Document Revision History Revision Date Author Description of change 10 07Jun13 Mark Benton Removed Admin. Manager from approval 12Feb13 Mark Benton 08 01Oct12 Mark Benton 07 8/30/2012 Refer
ISO 9001:2008 Quality Management System Requirements (Third Revision)
ISO 9001:2008 Quality Management System Requirements (Third Revision) Contents Page 1 Scope 1 1.1 General. 1 1.2 Application.. 1 2 Normative references.. 1 3 Terms and definitions. 1 4 Quality management
ISO 9001:2008 Audit Checklist
g GE Power & Water ISO 9001:2008 Audit Checklist Organization Auditor Date Page 1 Std. 4.1 General s a. Are processes identified b. Sequence & interaction of processes determined? c. Criteria for operation
ISO 9001 (2000) QUALITY MANAGEMENT SYSTEM ASSESSMENT REPORT SUPPLIER/ SUBCONTRACTOR
Page 1 of 20 ISO 9001 (2000) QUALITY MANAGEMENT SYSTEM ASSESSMENT REPORT SUPPLIER/ SUBCONTRACTOR SUPPLIER/ SUBCONTRACTOR NAME: ADDRESS: CITY AND STATE: ZIP CODE: SUPPLIER/MANUFACTURER NO PHONE: DIVISION:
DNV GL Assessment Checklist ISO 9001:2015
DNV GL Assessment Checklist ISO 9001:2015 Rev 0 - December 2015 4 Context of the Organization No. Question Proc. Ref. Comments 4.1 Understanding the Organization and its context 1 Has the organization
ISO 9001: 2008 Boosting quality to differentiate yourself from the competition. xxxx November 2008
ISO 9001: 2008 Boosting quality to differentiate yourself from the competition xxxx November 2008 ISO 9001 - Periodic Review ISO 9001:2008 Periodic Review ISO 9001, like all standards is subject to periodic
Quality Management Systems Manual
Washington Division Quality Management Systems Manual ISO 13485:2003 DOCUMENT NUMBER 01-QM-MED REVISION LEVEL 01 PAGE 1 of 40 This manual describes the quality management systems structure at GM Nameplate
QUALITY MANUAL ISO 9001:2015
Page 1 of 22 QUALITY MANUAL ISO 9001:2015 Quality Management System Page 1 of 22 Page 2 of 22 Sean Duclos Owner Revision History Date Change Notice Change Description 11/02/2015 1001 Original Release to
Row Manufacturing Inc. Quality Manual ISO 9001:2008
Row Manufacturing Inc. Quality Manual ISO 9001:2008 Row Manufacturing 210 Durham Drive Athens, Alabama 35611 Phone:256.232.4151 Fax:256.232.4133 Page 2 of 33 This Page intentionally left Blank Page 3 of
QUALITY MANAGEMENT SYSTEM REQUIREMENTS General Requirements. Documentation Requirements. General. Quality Manual. Control of Documents
Chapter j 38 Self Assessment 729 QUALITY MANAGEMENT SYSTEM REQUIREMENTS General Requirements 1. Establishing and implementing a documented quality management system 2. Implementing a documented quality
Comparison between FDA QSR and ISO 13485
Comparison between FDA QSR and ISO 13485 Most countries in the world including the Europe, for the conformity assessment of medical devices to be used by their countrymen, assess not only whether the product
QUALITY MANUAL ISO 9001. Quality Management System
Page 1 of 20 QUALITY MANUAL ISO 9001 Quality Management System Printed copies are not controlled unless marked "CONTROLLED". Upon receipt of this document, discard all previous copies. Page 2 of 20 Approval
QUALITY MANAGEMENT SYSTEM Corporate
Page 1 of 12 4 Quality Management System 4.1 General Requirements The Peerless Pump Quality Management System shall include: Documented statements of a quality policy and of quality objectives; A quality
Quality Management System MANUAL. SDIX, LLC Headquarters: 111 Pencader Drive Newark, Delaware 19702
Quality Management System MANUAL SDIX, LLC Headquarters: 111 Pencader Drive Newark, Delaware 19702 Doc. No. G5500 Rev. 9.1 Status : APPROVED Effective: 12/11/2014 Page 2 of 23 Quality Manual Table of Contents
Quality Management System MANUAL. SDIX, LLC Headquarters: 111 Pencader Drive Newark, Delaware 19702
Quality Management System MANUAL SDIX, LLC Headquarters: 111 Pencader Drive Newark, Delaware 19702 Doc. No. G5500 Rev. 9.2 Status : APPROVED Effective: 9/25/2015 Page 2 of 23 Quality Manual Table of Contents
ISO 9001:2015 Overview of the Revised International Standard
ISO 9001:2015 Overview of the Revised International Standard Introduction This document provides: a summary of the new ISO 9001:2015 structure. an overview of the new and revised ISO 9001:2015 requirements
Quality Management System Manual
Effective Date: 03/08/2011 Page: 1 of 17 Quality Management System Manual Thomas C. West Eric Weagle Stephen Oliver President ISO Management General Manager Representative Effective Date: 03/08/2011 Page:
ISO 9001:2015 Internal Audit Checklist
Page 1 of 14 Client: Date: Client ID: Auditor Audit Report Key - SAT: Satisfactory; OBS: Observation; NC: Nonconformance; N/A: Not Applicable at this time Clause Requirement Comply Auditor Notes / Evidence
QW Enterprises, LLP. Quality Manual
QW Enterprises, LLP Quality Manual ISO 9001:2008 Quality Manual 9001 2008 D1 Quality Manual 9001 2008 D1 Page 2 of 34 0 Table of contents 0 Table of contents 2 1 General 5 1.1 Purpose and scope 5 1.2 Application
Vigilant Security Services UK Ltd Quality Manual
Quality Manual Date: 11 th March, 2014 Issue: 5 Review Date: 10 th March 2015 VSS-COM-PRO-001 SCOPE This Quality Manual specifies the requirements for the Quality Management System of Vigilant Security
CUSTOMER SPECIFIC REQUIREMENTS
CUSTOMER SPECIFIC REQUIREMENTS For Use With ISO 9001:2008 & ISO/TS 16949:2009 Page 1 SYSTEMS POLICY MANUAL CONTENTS Revision History Approval Document Distribution and Control General Application Background
Quality Management System Manual
Quality Management System Manual Assurance ISO / AS Manual Quality Management System EXCEEDING ALL EXPECTATIONS Since our inception in 1965, Swiss-Tech has supplied the medical, aerospace, hydraulic, electronic
Supplier Quality Agreements
Supplier Quality Agreements Dan O Leary CBA, CQA, CQE, CRE, SSBB, CIRM President Ombu Enterprises, LLC [email protected] www.ombuenterprises.com 603-209-0600 1 Speaker Biography Dan O Leary Dan O
Quality Management System Manual ISO9001:2008
Quality Management System Manual ISO9001:2008 Controlled Copy Rev. 3 Page 1 of 21 7/1/13 Table of Contents Company Profile...5 Past...5 Present...5 Mission...5 Vision...5 Locations...6 1 Scope...6 1.1
Karas Engineering AS9100 QUALITY MANAGEMENT SYSTEM MANUAL
Karas Engineering AS9100 QUALITY MANAGEMENT SYSTEM MANUAL Revision D October 27, 2015 Statement of Commitment and Authority Commitment This Quality Management System Manual (QMSM) delineates the processes,
QUALITY MANUAL 3 KENDRICK ROAD WAREHAM, MA 02571 508-295-9591 FAX 508-295-6752
QUALITY MANUAL 3 KENDRICK ROAD WAREHAM, MA 02571 508-295-9591 FAX 508-295-6752 Section 1. REVISION STATUS Revision 01 Initial Issue 02/13/95 Revision 02 ECO No.Q-0032 05/07/96 Revision 03 ECO No.97171
Micro Plastics, Inc. Quality Manual
ISO 9001:2008 11 Industry Lane Flippin, Arkansas 72634 QM-001-2008-F Page 2 of 39 Introduction Micro Plastics, Inc. developed and implemented a Quality Management System in order to document the company
QUALITY MANUAL REVISION RECORD
Page 2 of 31 REVISION RECORD Date Rev Description Jun 18, 2007 N/C Original Issue Sep 16, 2009 A Update to ISO 9001:2008 Standard. Feb 04, 2010 B Revised exclusions, removed (Except 7.3.7 from the exclusion
CENTRIS CONSULTING. Quality Control Manual
CENTRIS CONSULTING Quality Control Manual ISO 9001:2008 Introduction Centris Consulting developed and implemented a Quality Management System in order to document the company s best business practices,
Eagle Machining, Inc. Quality Management System
Eagle Machining, Inc. Quality Management System 1 of 10310 Antoine Drive Bldg D, Houston, Texas 77086 BUSINESS OPERATING MANUAL (QUALITY MANUAL) Revision Date: 08/01/2014 Approved By: Joseph Vu Date: 08/01/2014
Rev: Issue 4 Rev 4 Quality Manual AOP0101 Date: 10/07/13. Quality Manual. CBT Technology, Inc. 358 North Street Randolph, MA 02368
Quality Manual CBT Technology, Inc. 358 North Street Randolph, MA 02368 Issue 4 Revision 4 Note: updates are in italics Page 1 of 18 1.0 Scope and Exclusions Scope This Quality Manual contains policies
Quality Manual TABLE OF CONTENTS APPROVAL SIGNATURE PAGE 1.1 1 AMENDMENT RECORD 1.2 2 SCOPE 2.0 3 EXCLUSIONS 2.1 3
TABLE OF CONTENTS DESCRIPTION SECTION PAGE INTRODUCTION 1.0 1 APPROVAL SIGNATURE PAGE 1.1 1 AMENDMENT RECORD 1.2 2 SCOPE 2.0 3 EXCLUSIONS 2.1 3 CORPORATE POLICY 3.0 3 QUALITY MANAGEMENT SYSTEM 4.0 4 GENERAL
ISO 9001 Quality Systems Manual
ISO 9001 Quality Systems Manual Revision: D Issue Date: March 10, 2004 Introduction Micro Memory Bank, Inc. developed and implemented a Quality Management System in order to document the company s best
NORTH AMERICA OPERATIONS. (Fairmont and Montreal Facilities) QUALITY MANUAL. Prepared to comply with the requirements of ISO 9001:2008
WEIGH-TRONIX CANADA ULC NORTH AMERICA OPERATIONS (Fairmont and Montreal Facilities) QUALITY MANUAL Prepared to comply with the requirements of ISO 9001:2008 Meets or exceeds the requirements for design,
FINE LOGISTICS. Quality Manual. Document No.: 20008. Revision: A
FINE LOGISTICS Quality Manual Document No.: 20008 Revision: A 20008 Rev. A FINE LOGISTICS, Quality Manual Page 1 of 24 Quality Manual: Table of contents Number Section Page 1. GENERAL 3 1.1 Index and revision
Cartel Electronics. AS 9100 Quality Systems Manual
Cartel Electronics AS 9100 Quality Systems Manual 1900 C Petra Lane Placentia, California 92870 Introduction Cartel Electronics, as a global supplier to the aviation, space, and space industries, has developed
The Prophotonix (UK) Ltd Quality manual
The Prophotonix (UK) Ltd Quality manual Date: March 2014 Revision: D Sparrow lane, Hatfield Broad Oak, Herts, UK, CM22 7BA Tel: +44 (0)1279 717170 Fax: +44 (0)1279 717171 e-mail: [email protected] Page
Summary of GE Healthcare's Quality Management System (QMS) Covering BioProcess chromatography media, equipment, software, and spare parts
GE Healthcare Summary of GE Healthcare's Quality Management System (QMS) Covering BioProcess chromatography media, equipment, software, and spare parts Table of content General requirements 3 Documentation
Quality Agreement Template
Quality Agreement Template Prepared by Dan O Leary Ombu Enterprises, LLC 3 Forest Ave. Swanzey, NH 03446 603-209-0600 This document is intended to form the basis for a Supplier Agreement. The document
ISO 9001:2008 QUALITY MANUAL. Revision B
ISO 9001:2008 QUALITY MANUAL Revision B Because we want you to achieve the highest levels of performance, we connect care Because with leading we want science you to achieve continuously the highest improve,
Disclosure to Promote the Right To Information
इ टरन ट म नक Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information
INTEGRATED MANAGEMENT SYSTEM MANUAL IMS. Based on ISO 9001:2008 and ISO 14001:2004 Standards
INTEGRATED MANAGEMENT SYSTEM MANUAL IMS Based on ISO 9001:2008 and ISO 14001:2004 Standards Approved by Robert Melani Issue Date 30 December 2009 Issued To Management Representative Controlled Y N Copy
QUALITY MANAGEMENT SYSTEM (QMS) MANUAL
QUALITY MANAGEMENT SYSTEM (QMS) MANUAL This document and the data contained herein are the property of ISOLINK, and shall not, without prior written permission, be reproduced or used for any unintended
Correlation matrices between 9100:2009 and 9100:2016
Correlation matrices between 9100:2009 and 9100:2016 This document gives correlation matrices from 9100:2009 to 9100:2016. This document can be used to highlight where the new and revised clauses are located.
Turbo Resources International Quality Procedure
TURBO RESOURCES INTERNATIONAL QUALITY MANAGEMENT SYSTEM MANUAL APPROVALS: Revision : 46 Page : 1 of 53 TABLE OF CONTENTS INTRODUCTION 3 1. SCOPE 4 1.1 GENERAL 4 1.2 APPLICATION 5 2. NORMATIVE REFERENCE
QUALITY MANAGEMENT SYSTEM (QMS) ASSESSMENT CHECKLIST
1. QUALITY MANAGEMENT SYSTEM QUALITY MANAGEMENT SYSTEM (QMS) ASSESSMENT CHECKLIST 1.1 Quality Management System General 1.1.1 Is objective evidence available to demonstrate that the MDSAP site has defined,
Uncontrolled Document
SOUTHWEST RESEARCH INSTITUTE QUALITY SYSTEM MANUAL July 2015 Revision 5 Quality System Manual Page iii TABLE OF CONTENTS 1.0 PURPOSE... 1 2.0 SCOPE... 1 3.0 TERMS AND DEFINITIONS... 2 4.0 QUALITY MANAGEMENT
The President of Inductors Inc. is the senior executive responsible for operations.
Title: Quality Management System Manual Page: 1 of 20 INTRODUCTION Inductors Inc., founded in 1991, specializes in the distribution of inductive components, including but not limited to standard and custom
14620 Henry Road Houston, Texas 77060 PH: 281-447-3980 FX: 281-447-3988. WEB: www.texasinternational.com QUALITY MANUAL
14620 Henry Road Houston, Texas 77060 PH: 281-447-3980 FX: 281-447-3988 WEB: www.texasinternational.com QUALITY MANUAL ISO 9001:2008 API Spec Q1, 9th Edition API Spec 8C 5 Th Edition MANUAL NUMBER: Electronic
PUBLICATIONS. Introduction
Page: 1 of 10 Introduction 1. The requirements of this document supplement the Factory Production Control requirements given in Table 1 of PN111 by giving the specific requirements for Factory Production
Quality Manual Printed copy valid for 24 hours from time of printing unless stamped CONTROLLED COPY in red. Page
Quality Manual Page 1 of 20 Change Log Document Revision Date Description of Change 15/04/09 Initial Release Page 2 of 20 1.0 Scope and Exclusions Scope This Quality Manual contains policies that have
SUPPLIER QUALITY MANAGEMENT SYSTEM QUESTIONNAIRE
Company Name Street Address City, State, Zip code Phone Number Fax Company Website Email Address ORGANIZATION NAME PHONE NUMBER EMAIL ADDRESS President/CEO General Manager Engineering Manager Production
Free Download ISO/TS 16949:2009. Requirements Checklist. 29 of 57 pages (PDF) For additional information see www.rcglobal.com
RCGLOBAL.COM Free Download ISO/TS 16949:2009 Requirements Checklist 29 of 57 pages (PDF) For additional information see www.rcglobal.com RCGLOBAL(Canada), for internal use only. Page 1 of 57 Review performed
Quality & Safety Manual
Purpose: This Quality & Safety Manual is intended to clarify and document the Quality and Health & Safety policies of GGS Oil and Gas Systems and to describe how the organization organizes its activities
This Business Management System Manual is based on ISO 9001:2008 requirements
Page 1 of 19 (Formerly: Quality Management System Manual) When the ISO 9001:2008 standard is identifying the Quality Manual or Quality Management System, Turbonetics is representing this requirement with
FINAL DOCUMENT. Guidelines for Regulatory Auditing of Quality Management Systems of Medical Device Manufacturers Part 1: General Requirements
GHTF/SG4/N28R4:2008 FINAL DOCUMENT Title: Guidelines for Regulatory Auditing of Quality Management Systems of Medical Device Manufacturers Authoring Group: GHTF Study Group 4 Endorsed by: The Global Harmonization
Camar Aircraft Products Co. QUALITY MANUAL Revision D
QUALITY MANUAL Revision D Gujll'y Manual Introduction The purpose of this manual is to describe the Quality Assurance Program implemented by Camar Aircraft Products Co. (hereafter referred to as C.A.P.C.)
Supplier Quality Management System Audit Checklist (ISO 9000:2000, TS 16949:2002)
Supplier Quality Management System Audit Checklist (ISO 9000:2000, TS 16949:2002) Supplier: Plant/Location: Date: Audit Team: Scope of Audit: Number of C.A.R. s: Corrective Action Due: Potential suppliers
Contents. Management Policy Manual SEM USA Page 2 of 12
SEM USA Page 2 of 12 Contents 1. The Schneider Electric Motion USA Management Policy... 3 2. PROCESS INTERACTION... 4 3. COMPANY OBJECTIVES:... 5 4. MANAGEMENT SYSTEM... 6 4.1. General Requirements...
Quality Systems Manual
Quality Systems Manual This manual was developed to support ISO 9001 elements Revision Description of Change Author Effective Date 5-28-02 Initial Release Support ISO 9001: 2000 L. Hook 5-28-02 7-01-02
ED FAGAN INC. QUALITY SYSTEM MANUAL
ED FAGAN INC. QUALITY SYSTEM MANUAL APPROVED BY: Ed Fagan President ED FAGAN INC. January 13, 2010 TABLE OF CONTENTS 1. PURPOSE AND SCOPE 2 2. PRODUCTS, SERVICES AND CAPABILITIES 2 3. REVISION HISTORY
ALL PRODUCTS MFG & SUPPLY
ALL PRODUCTS MFG & SUPPLY 618 ANDERSON DRIVE ROMEOVILLE, IL 60446 PHONE: 877-255-8700 FAX: 877-255-8701 WWW. APGASKET.COM QUALITY MANAGEMENT SYSTEM MANUAL DATE: 11/20/12 REVISION 9.1 UNCONTROLLED COPY
Quality Management System Manual
Quality Management System Manual This manual has been reviewed and approved for use by: Jack Zazulak President, Aurora Machine Limited March 07, 2011 Date - Copyright Notice - This document is the exclusive
Quality Management System General
Audit Date: Quality Management System General Requirement: 4.1 and 4.2.2-QMS General Verify Scope Comments/Evidence/Findings: Verify the Exclusions is applicable and justified How are the processes in
Control No: QQM-02 Title: Quality Management Systems Manual Revision 10 07/08/2010 ISO 9001:2008 Page: 1 of 22
ISO 9001:2008 Page: 1 of 22 Central Technologies has developed a Quality Management System, and the associated procedures and work instructions, to be compliant to ISO 9001:2008. Utilizing this Quality
ISO 9001 : 2000 Quality Management Systems Requirements
A guide to the contents of ISO 9001 : 2000 Quality Management Systems Requirements BSIA Form No. 137 February 2001 This document is the copyright of the BSIA and is not to be reproduced without the written
Quality Manual. UK Wide Security Solutions Ltd. 1 QM-001 Quality Manual Issue 1. January 1, 2011
Quality Manual 1 QM-001 Quality Manual Issue 1 January 1, 2011 This document is uncontrolled when printed. Please verify with Quality Management Representative 16 Dukes Close, West Way, Walworth Industrial
AS9100 Quality Manual
Origination Date: August 14, 2009 Document Identifier: Quality Manual Revision Date: 8/5/2015 Revision Level: Q AS 9100 UNCONTROLLED IF PRINTED Page 1 of 17 1 Scope Advanced Companies (Advanced) has established
QUALITY MANAGEMENT SYSTEMS
QM-1 QUALITY MANAGEMENT SYSTEMS MANUAL Revision 7 Page: 1 of 57 This document contains proprietary information and is not lo be distributed to or copted for a third party without the express written permission
QUALITY ASSURANCE MANUAL JPM OF MISSISSIPPI, INC.
QUALITY ASSURANCE MANUAL JPM OF MISSISSIPPI, INC. Hattiesburg, MS Revision E 01/19/11 Revised to ISO 9001:2008 on July 9, 2009 JPM OF MISSISSIPPI, INC. MANAGEMENT QUALITY POLICY It is the goal of JPM of
ISO 9001:2008 STANDARD OPERATING PROCEDURES MANUAL
8200 Brownleigh Drive Raleigh, NC 27617-7423 Phone: (919) 510-9696 Fax: (919) 510-9668 ISO 9001:2008 STANDARD OPERATING PROCEDURES MANUAL ALLIANCE OF PROFESSIONALS & CONSULTANTS, INC. - 1 - Table of Contents
ABC COMPANY INC ISO 9001:2000 QUALITY MANUAL
Page 1 of 25 ABC COMPANY INC QUALITY MANUAL Page 2 of 25 DOCUMENT INTRODUCTION PURPOSE OF THIS MANUAL This describes the quality management system at ABC Company Ltd, Buffalo, USA described as the Organization,
ISO 9001:2008 Quality Systems Manual
ISO 9001:2008 [Company Name] ADDRESS Phone: Phone: Fax: Fax: The holder of this manual is cautioned that the information contained herein must not be loaned or circulated outside of [Company Name] except
This interpretation of the revised Annex
Reprinted from PHARMACEUTICAL ENGINEERING The Official Magazine of ISPE July/August 2011, Vol. 31 No. 4 www.ispe.org Copyright ISPE 2011 The ISPE GAMP Community of Practice (COP) provides its interpretation
Medical Device Training Program 2015
Medical Device Training Introduction Supplementary training and education is often overlooked by medical device professionals until it is triggered by an upcoming FDA or Notified Body and/or ISO 13485
Preparing for Unannounced Inspections from Notified Bodies
Preparing for Unannounced Inspections from Notified Bodies Europe has introduced further measures for unannounced audits of manufacturers by notified bodies. With this in mind, James Pink, VP Europe-Health
Specialties Manufacturing. Talladega Castings & Machine Co., Inc. ISO 9001:2008. Quality Manual
Specialties Manufacturing Talladega Castings & Machine Co., Inc. ISO 9001:2008 This document is the property of TMS and may not be reproduced, wholly, or in part, without the express consent of TMS. Rev.
EMS Example Example EMS Audit Procedure
EMS Example Example EMS Audit Procedure EMS Audit Procedures must be developed and documented with goals which: Ensure that the procedures incorporated into the EMS are being followed; Determine if the
Quality Manual. DuraTech Industries, Inc. 3216 Commerce Street La Crosse, WI 54603 MANUAL SERIAL NUMBER 1
Quality Manual Approval Page Document: QA1000 Issue Date: 5/29/1997 Page 1 of 17 Revision Date: 5/20/2013 DuraTech Industries, Inc. 3216 Commerce Street La Crosse, WI 54603 MANUAL SERIAL NUMBER 1 This
GENERIC STANDARDS CUSTOMER RELATIONSHIPS FURTHER EXCELLENCE CUSTOMISED SOLUTIONS INDUSTRY STANDARDS TRAINING SERVICES THE ROUTE TO
PROCESSES SUPPLY CHAIN SKILLED TALENT CUSTOMER RELATIONSHIPS FURTHER EXCELLENCE GENERIC STANDARDS INDUSTRY STANDARDS CUSTOMISED SOLUTIONS TRAINING SERVICES THE ROUTE TO ISO 9001:2015 FOREWORD The purpose
FINAL DOCUMENT. Title: Quality Management System Medical Devices Guidance on the Control of Products and Services Obtained from Suppliers
GHTF/SG3/N17:2008 FINAL DOCUMENT Title: Quality Management System Medical Devices Guidance on the Control of Products and Services Obtained from Suppliers Authoring Group: GHTF Study Group 3 Endorsed by:
PROPOSED DOCUMENT. Quality management system Medical devices Nonconformity Grading System for Regulatory Purposes and Information Ex-change
AHWP/WG3/P001:2013 PROPOSED DOCUMENT Title: Quality management system Medical devices Nonconformity Grading System for Regulatory Purposes and Information Ex-change Author: AHWP Work Group 3 Date: 13 November
Quality Management System Manual Revision L
This Page 1 of 35 of the Quality Management System Manual If issued as a controlled copy, the serial number of this copy is Quality Management System Manual Certified to AS9100 Revision C Printed copies
FMC Technologies Measurement Solutions Inc.
Table of Contents 1 Revision History... 4 2 Company... 5 2.1 Introduction... 5 2.2 Quality Policy... 6 2.3 Quality Organization... 6 2.4 Company Processes... 7 3 Scope and Exclusions... 8 3.1 Scope...
ISO 9001:2015 Revision overview
ISO 9001:2015 Revision overview December 2013 ISO/TC 176/SC 2/WG23 N063 1 Purpose of presentation To provide an overview of the revision of ISO 9001 which will be published in 2015 2 Background to this
ISO 9001:2008 Requirements Explained - An Adobe PDF File for Use on a Network System
1-2 3 4 5 6 9 9 29 37 44 57 64 67 70 77 85 90 93 97 101 110 112 113 122 125 127 135 139 146 150 157 161 165 168 172 175 180 187 190 193 201 206 209 212 216 227 233 235 247 251 258 264 272 274 286 1 of
0. 0 TABLE OF CONTENTS
QUALITY MANUAL Conforming to ISO 9001:2000 0. 0 TABLE OF CONTENTS Section Description ISO 9001 Clause Page 0 TABLE OF CONTENTS n/a 2 1 PIMA VALVE, INC. DESCRIPTION n/a 3 2 QUALITY MANUAL DESCRIPTION 4.2.2
ISO 9001:2000 - A Quality Manual for the Transition Period and Beyond
ISO 9001:2000 - A Quality Manual for the Transition Period and Beyond By Mark Kaganov Abstract This article shows a practical approach to converting an ISO 9001:1994 quality manual into the new ISO 9001:2000
Quality Manual ALABAMA RESEARCH & DEVELOPMENT. This Quality Manual complies with the Requirements of ISO 9001:2008.
ALABAMA RESEARCH & DEVELOPMENT This complies with the Requirements of ISO 9001:2008. Prepared By: Phyllis Olsen Release Date: 03/19/09 Quality Policy & Objectives s quality policy is to achieve sustained,
John Tighe ISO 9001 Lead Auditor & Scheme Champion. Alongside CD1, the ballot for 3 specific questions agreed in Sept 2013.
ISO 9001:2015 Draft. Fergal O Byrne, Head of Business Excellence Certification. John Tighe ISO 9001 Lead Auditor & Scheme Champion. NSAI 1 Alongside CD1, the ballot for 3 specific questions agreed in Sept
UL Qualified Firestop Contractor Program Management System Elements. March 13, 2013
UL Qualified Firestop Contractor Program Management System Elements March 13, 2013 UL and the UL logo are trademarks of UL LLC 2013 Benefits to becoming a Qualified Firestop Contractor Independent, 3 rd