Structural. Technical Brochure. Canadian Precast/Prestressed Concrete Institute
|
|
|
- James Harmon
- 9 years ago
- Views:
Transcription
1 Structural Precast/Prestressed Concrete Technical Brochure Canadian Precast/Prestressed Concrete Institute
2 Table of Contents Benefits...3 Flooring/Roofing...5 Hollow Core Slabs...5 Hollow Core Specifications...13 Precast/Prestressed Double Tees...16 Framing...18 Structural Specifications...23 Long Span Parking Garages...29 Specialized Uses...34 Bridges...36 Heavy Industrial...38 What it Means to be a CPCI Member The Canadian Precast/Prestressed Concrete Institute is a non-profit corporation founded in 1961 for the purpose of advancing the design, manufacture and use of structural and architectural precast/prestressed concrete throughout North America. Members CPCI is a unique combination of trade and professional association, with a representative mix of companies and individuals. Its membership includes precast producers (Active members), suppliers (Associate Members and Supporting Members), engineers and architects (Professional members), plus affiliate and student members. These members receive CPCI & PCI technical information and discounts on conventions and publications. Consult the CPCI website for more information and an application form. Technology CPCI members are committed to developing innovative solutions to meet the demands of the construction industry. Three annual technical committee meetings are held to collect and disseminate knowledge, statistics, ideas and information relating to the design, manufacture, and use of precast/prestressed concrete. Through investigations and research, new engineering processes are established to improve quality and product design. Professional Development CPCI professional development education seminars (Pathways To Our Future) study systems and procedures to improve the coordination and dissemination of information relevant to our member s manufacturing processes. In addition, our seminars seek to improve managerial aspects of precast manufacturing and marketing through education and professional development. The aim is to improve to the efficiency and effectiveness of the industry as a whole. The CPCI Difference CPCI members are precast professionals; capable and willing to help you complete your next project. Involve your precast partner at the early stages of project planning. Whether the challenges are structural, aesthetic, timing or economic, CPCI members can provide invaluable input. You will find CPCI members are dedicated, committed and competent to contribute to the realization of the standards you have set for your projects. They will be there to advise and assist you from concept to completion. Consult the CPCI website: for the members near you. 2
3 Structural Precast/Prestressed Concrete Speed Benefits Structural precast concrete elements are manufactured under controlled plant conditions at the same time as site foundation work is being prepared. When the site is ready, the precaster can immediately commence with the erection of the components, dramatically shortening construction time. This reduces on-site congestion, financing costs, while accelerating the occupancy date. Quality/Durability Lasting benefits of precast concrete are inherent. High strength, high density, quality controlled precast concrete is superior to other building products for durability, corrosion resistance, impact resistance, fire resistance, security and long lasting low maintenance. The assurance of concrete product quality is achieved through environmentally controlled manufacturing conditions with a skilled workforce and a stringent inspection and concrete testing program in accordance with the requirements of the CSA precast concrete certification program. When precast concrete is prestressed, a further benefit to durability and slenderness of construction is realized. This active form of reinforcing keeps the concrete in compression which minimizes cracking and increases the load carrying capacity. Long Spans/Heavy Loads High quality plant cast/controlled concrete produced with optimum curing conditions translates to a high strength, high quality product increasing load capacities and resulting in more efficient sections. 3
4 Flexibility Custom manufactured precast units are easily incorporated into a building to accommodate non-typical shapes or sizes. Precast elements can be designed for easy removal and/or reuse to accommodate future building expansions and renovations. All Weather Construction Plant cast concrete units minimize weather incurred construction delays. Economy Low Maintenance Precast reduces costly maintenance shutdowns for painting and other repairs which translates into reduced costs and ensures maximum productivity over the life of a structure. Few materials have the cost benefit advantages of precast/prestressed concrete when life cycle costs are considered. Structural precast/prestressed concrete with faster construction time, low maintenance, long life and potential reduced insurance premiums all contribute significantly to overall savings. Benefits 4
5 Structural Precast/Prestressed Concrete Flooring/Roofing Precast/Prestressed Hollow Core Slabs & Double Tees Hollow Core Slabs Hollow core slabs are high quality precast/prestressed concrete units. Continuous voids are formed through each unit to reduce weight and improve structural performance. Application Hollow core slabs can be used for most applications requiring a floor or roof system. Office buildings, condominiums, hotels, senior citizen s apartments, commercial buildings, residential dwellings, houses of worship, nursing homes and educational facilities are all ideal applications. Fast Track Construction Hollow core slabs are engineered products that are ideal for very demanding construction schedules. Manufacturing of the product proceeds in a precaster s high efficiency plant while site construction is underway. Slabs are delivered to the jobsite and installed to meet the client s schedule regardless of weather conditions. The installed precast deck provides a working platform for other trades. Fast construction means earlier completion and resulting cost savings. 5
6 Hollow Core Slabs continued... Quality/Durability CPCI members supplying hollow core precast/prestressed slabs are CSA certified under strict controls to ensure that each slab meets high quality control standards. Hollow core slabs are produced using non-combustible materials. The fire rating of precast/prestressed hollow core slabs provide excellent protection of lives and property. In the event of a fire, hollow core slabs are less costly to refurbish. This fire resistance usually results in reduced insurance rates. Spans/Loads Hollow core slabs are available in 152mm, 203mm, 254mm, 305mm, and 355mm (6, 8, 10, 12 and 14 ) thickness and can span up to 16.15m (53 0 ). Consult your local CPCI member for the sizes available in your area. Precast/prestressed hollow core slabs combine high compressive strength plant cast concrete with high tensile strand. These materials in combination, allow long column free spans and high load capacity. The smooth ceiling provided by a hollow core slab requires only caulking of the longitudinal joints and a coat of textured paint to give a pleasing finish. The continuous voids can be used as heating/cooling ducts and as raceways for electrical wiring. Hollow core slabs reduce sound transmission and vibrations between floors and eliminate floor squeeks. Hollow core slabs meet or exceed the requirements of the National Building Code of Canada, the Canada Mortgage and Housing Corporation and the specifications and inspection requirements of the CSA International Erection CPCI hollow core manufacturers have available their own forces to install the precast /prestressed slabs. Services are also available to cut holes and openings up to 152mm (6 ) diameter for mechanical trades. Openings larger than 152mm (6 )should be located on shop drawings at the time of approval. Manufacturers can also provide a suitable top finish to accept the direct application of finished flooring/roofing materials. Support Requirements Hollow core slabs can be supported on many types of supports designed to carry the dead and live loads required. Precast beams, precast walls, poured concrete, masonry, insulated concrete forming systems, wood, steel studs and structural steel beams are all suitable as load bearing systems. Flooring/Roofing 6
7 Prestressed Hollow Core Slabs 152mm slab 6 slab / 8 Spans to 7m (23 ) 203mm slab 8 slab / 8 Spans to 9.75m (32 ) 254mm slab 10 slab / 8 Spans to 11.25m (37 ) 305mm slab 12 slab / 8 Spans to 13.70m (45 ) 355 mm slab 14 slab / 8 Spans to 16.15m (53 ) Contact your local CPCI member for specific sizes, span/loading and detailing information. Flooring/Roofing 7
8 Connections to Masonry/Steel/Precast End Bearing On Block - Half Bearing - Tie Up N.T.S. Side Bearing On Block - Half Bearing - Tie Up N.T.S. End Bearing On Block - Abutting - Tie Across N.T.S. End Bearing On Steel - (63mm or 2½ min) - Tie Down N.T.S. All connections shown are to be used for concept design only. Precast Slab Bearing On Precast Beam N.T.S. Flooring/Roofing 8
9 Connections to Structural Wood & Balcony Details End Bearing On Wood Studs - Bolted Connection N.T.S. Side Bearing - Bolted Connection N.T.S. Cantilevered Balcony - Tie Down N.T.S. All connections shown are to be used for concept design only. Solid Precast Balcony (Supported On Wing Walls) - Tie Across & Down N.T.S. Flooring/Roofing 9
10 Individually identified units being installed. Customized shear key. Grouting of shear key for load transference. Fast and efficient installation techniques. Clean, neat and open concept. Single level column and beam connection. Custom designed balcony. Steel hangers allow large openings for stairs, ductwork and other mechanical services. Pipe installation and sealing by mechanical trade follows core drilling. Cores used as raceways by electrical trades. Attractive stippled exposed ceiling. Flooring/Roofing 10 Top surface prepared to receive flooring materials.
11 Environmentally controlled production facility. All weather construction. Custom produced precast stored in yard while site is being prepared. Precast units loaded on trucks ready for delivery. Timely erection. Flooring/Roofing 11
12 Residential application. Versatile hollow core units can be designed to suit many applications. Long spans offer open concept design. Hollow core provides an immediate working platform. Precast is ideal for retrofit projects. Flooring/Roofing 12
13 Structural Precast/Prestressed Concrete Hollow Core Specifications Section Hollow Core Precast/Prestressed Concrete 1.0 General 1.1 Description.1 The General conditions of the Contract and Supplementary General Conditions apply to this Division, except as qualified herein and/or excluded..2 Refer to drawings and specifications. 1.2 Related Work.1 Cast-in-Place Concrete: Section Reference Standards Spec Note: List latest standards. Specifier to update specifications to latest edition..1 Do precast/prestressed concrete work in accordance with CSA A23.4 and CSA A Do welding in accordance with CSA W59 for welding to steel structures and CSA W186 for welding reinforcement. 1.4 Qualifications of Manufacturer.1 Manufacturers of precast/prestressed concrete elements to be members in good standing of the Canadian Precast/Prestressed Concrete Institute and certified by CSA in accordance with CSA A23.4 Precast Concrete - Materials and Construction and CSA A251 Qualification Code for Architectural and Structural Precast Concret Products. 1.5 Design Criteria.1 Design precast/prestressed concrete units to CSA A23.3 and to carry handling stresses..2 Design loads in accordance with applicable codes for use and occupancy, wind, temperature, and earthquake..3 Consider vibration characteristics in accordance with NBC..4 Design prestressed units to meet one (1) or two (2) hour fire resistance rating (specify). 1.6 Source Quality Control.1 Upon request, provide Engineer with certified copies of quality control tests and inspection related to project as specified in CSA A23.4 and CSA G Inspection of prestressed concrete tendons is required in accordance with CSA G Upon request, provide Engineer with certified copy of mill test report of reinforcing steel supplied, showing physical and chemical analysis. 13
14 Hollow Core Specifications continued Shop Drawings Spec Note: It is not the Precast Manufacturer s responsibility to confirm and correlate dimensions at the job site..1 Submit shop drawings in accordance with Section Shop Drawings, Product Data..2 Submit shop drawings in accordance with CSA A23.4 and CSA A23.3. Upon request, the following items shall be provided:.1 Design calculations for items designed by Manufacturer.2 Estimated camber.3 Finishing schedules.4 Methods of handling and erection.5 Openings, inserts and related reinforcement.3 Each drawing submitted to bear stamp of qualified Professional Engineer registered in the Province of. 1.8 Warranty.1 This Contractor hereby warrants that the precast/prestressed elements will not spall or show visible evidence of cracking, except for normal hairline shrinkage cracks, in accordance with the General Conditions warranty clause, for a one year period. 2.0 Products 2.1 Materials.1 Cement, aggregates, water, admixtures: To CSA A23.4 and CSA A Prestressing steel: Uncoated 7 wire cable conforming to CSA G Reinforcing steel: To CSA G Anchorages and couplings: To CSA A Embedded steel: To CSA G40.21, Type M300W.6 Welding materials: To CSA W Bearing pads: 3mm masonite smooth one side..8 Insulation: Expanded polystyrene to CAN/CGSB Air entrainment admixtures: To CSA A Chemical admixtures: To CSA A Concrete Mixes.1 Use concrete mix designed to produce 41 MPa (6000 p.s.i.) compressive cylinder strength at 28 days with maximum water/cement ratio to CSA A23.1, Table 7 for Class D exposure..2 Air entrainment of concrete mix: To CSA A Admixtures: To CSA A266.4, CSA A Do not use calcium chloride or products containing calcium chloride. 2.3 Grout Mix.1 Cement grout: One part type 10 Portland cement 2½ parts sand, sufficient water for placement and hydration. 2.4 Manufacture.1 Manufacture units in accordance with CSA A Mark each precast unit to correspond to identification mark on shop drawings for location on part of unit which will not be exposed..3 Provide hardware suitable for handling elements..4 Provide 50mm (2 ) thick insulation plug at each cell end of hollow core at exterior. (optional) Flooring/Roofing 14
15 Hollow Core Specifications continued Execution 3.1 Erection.1 Erect elements within allowable tolerances indicated or specified..2 Non-cumulative erection tolerances in accordance with CSA A23.4, Section Install 3mm masonite bearing pads, smooth side up on bearing ends of concrete or masonry..4 Set units in a tight, level position on true level bearing surface provided by others. Minimum bearing 90mm (3½ ) on masonry and 75mm (3 ) on structural steel..5 Fasten precast/prestressed units in place as indicated on reviewed shop drawings..6 Level differential elevation of horizontal joints with grout to slope not more than 1:12..7 Clean field welds with wire brush and touch up with primer..8 Field cut holes and openings up to 150mm (6 ) diameter for mechanical trades. Openings larger than 150mm (6 ) to be located on shop drawings at time of approval and to be cut in field. Do not cut reinforcing without approval of precast hollow core slab manufacturer and Engineer. 3.2 Topping.1 This contractor shall provide a suitable top finish to accept direct application of finished flooring/roofing as per room finish schedule..2 Where concrete topping (minimum 37mm [1½ ]) is to be applied, refer to appropriate specifications. The top surface of the precast/prestressed slabs is to be raked (roughened) for bonding of topping. 3.3 Exposed Ceilings.1 Caulk exposed ceiling longitudinal joints, using standard caulking..2 The underside of precast shall be finished as per CSA A23.4 (clause ) STANDARD FINISH. 3.4 Clean-Up.1 Upon completion of the work of this section, all surplus material and debris shall be removed from the site. End of Section Spec Note: *Items relating to precast/prestressed slabs to be carried out by other trades, and covered in their respective specifications; (1) Drypacking of gap between precast/prestressed slabs at all locations where load bearing walls are parallel to length of slab. (2) Perimeter caulking. (3) Electrical holes. (4) Concrete topping (37 mm [1½ ]±) Flooring/Roofing 15
16 Precast/Prestressed Double Tees Double tees offer beauty and flexibility in design. These precast/prestressed concrete units are ideal for floor and roof systems requiring long, uninterrupted spans and extra heavy load carrying capabilities. The remarkable strength of a double tee is the result of a design and manufacturing system that uses the best attributes of steel and concrete. Consider double tees for longer spans and heavier loads which exceed the capacity of hollow core slabs. Special Features Double tees are known for their great resiliency. Long spans with exposed ceilings require no additional finishes. A superior smooth steel form finish as well as excellent fire ratings are provided by double tee construction. Double tees can be designed to allow openings to be placed in the flange areas between the stems. This allows for the installation of windows/skylights and mechanical ducts. Typical building uses for double tees include parking decks, water/sewage treatment plants, food processing plants, heavy industrial buildings, warehouses, indoor pools and gymnasiums. Design Stage Assistance Available CPCI hollow core and double tee manufacturers can provide budget pricing and technical assistance at the preliminary design stage for your next project. Typical Double-Tee Detail Note: Double Tees may or may not receive a field applied topping. Contact your local CPCI member for further details. Flooring/Roofing 16
17 Consistant quality unmatched by field casting. Dense durable material with excellent resiliency. Speedy installation allows immediate access for subsequent trade contractors. Double Tees provide uninterrupted longspans for this water treatment facility. Flooring/Roofing 17
18 Structural Precast/Prestressed Concrete Framing Shape and Design Precast/prestressed components are custom manufactured to match design requirements. Unusual shapes, sizes and specific technical requirements are expertly fabricated in CPCI member precast plants. Repetition of shapes and sizes will greatly enhance the economical use of precast components. Precast Efficiency The continuous, uninterrupted erection of precast structural components lends itself perfectly to fast track construction schedules. Savings on financing costs, (faster return on investments resulting from bringing the structure into productive life sooner) is just one of the benefits provided by a complete precast building system. Precast Structural Components Precast concrete beams, columns and stairs are the ideal solution for owners and builders who want to achieve wide open spans, fire resistance, energy savings and attractive design with one structural system. These components are suitable for both low and high-rise structures. Highly durable, these concrete units can be installed in all weather conditions. Precast beams may be either continuous with single story columns or single span beams with multi-story columns. The use of standardized forms accelerates the manufacturing process. The quality of smooth formed finishes produced in a precast plant saves money by allowing designers to expose the structure in a finished building. 18
19 Open shear wall designed to take horizontal load transfer. Multi-level beam and column framing Post tensioned transfer beam. Single storey beam structure. Long span double tees are ideal for food processing facilities. Framing 19
20 Framing is quickly assembled immediately after site work. Construction of a multilevel parking structure. Precast concrete raker beams are ready to receive bleacher seating. Placement of a raker beam. Framing 20
21 Col.-Ftg. Connection N.T.S. Beam - Column Connection N.T.S. Multiple Beam - Column Connection N.T.S. Precast Slab Connection to Column N.T.S. All connections shown are to be used for concept design only. Framing 21
22 Precast Slab Bearing on Precast Beam N.T.S. Precast Slab Side Bearing on Precast Beam N.T.S. Precast Slab Bearing on Precast Beam N.T.S. Precast Slab Bearing on Precast Beam N.T.S. All connections shown are to be used for concept design only. Framing 22
23 Structural Precast/Prestressed Concrete Structural Specifications Section Structural Precast/Prestressed Concrete 1.0 General 1.1 Description.1 The General conditions of the Contract and Supplementary General Conditions apply to this Division, except as qualified herein and/or excluded..2 Refer to drawings and specifications. 1.2 Work Included.1 Design, supply, delivery and installation of: Spec Note: This section includes structural precast/prestressed concrete units including the following: Double tee slab units Structural framing units Parking structures Structural precast/prestressed concrete Spec Note: This section specifies products of standard or special shapes that are reinforced using steel reinforcement, pre-tensioning or post-tensioning and through application become an integral structural part of the project..1 The specifications cover precast/prestressed structural concrete construction..2 This section includes product design, manufacture, transportation, erection and other related items such as anchorage, bearing pads, inserts and similar accessories required for work under this contract..3 Take delivery and cast into precast work boxes/inserts/openings required and supplied by other trades only if supplied prior to casting..2 Supply information required for the installation of bracing, supports, inserts and similar accessories required for the work under this contract supplied and to be installed by others. 1.3 Related Work.1 Section Cast-in-Place Concrete.2 Section Cast-in-Place Concrete: Setting only of insert or anchors unless otherwise noted on Structural Drawings.3 Section Hollow Core Precast/Prestressed Concrete.4 Section Architectural Precast Concrete and/or Insulated Precast Concrete Wall Panels.5 Section Structural Metal Framing Spec Note: For parking structures add reference to concrete topping and deck waterproofing. 23
24 Structural Specifications continued... Structural Precast/Prestressed Concrete 1.4 Reference Standards Spec Note: Latest standards are listed. Specifier to update specifications to latest edition..1 CSA A , Concrete Materials and Methods of Concrete Construction.2 CSA A , Methods of Test for Concrete.3 CSA A , Design of Concrete Structures.4 CSA A , Precast Concrete-Materials and Construction.5 CSA A251-00, Qualification Code for Architectural and Structural Precast Concrete Products.6 CSA A , Qualification Code for Concrete Testing Laboratories.7 CSA G30.5-M, Weld Steel Wire Fabric for Concrete Reinforcement.8 CSA G30.15-M, Welded Deformed Steel Wire Fabric for Concrete Reinforcement.9 CAN/CSA G30.18, Billet Steel Bars for Concrete Reinforcement.10 CAN/CSA G40.21, Structural Quality Steel.11 CAN/CSA-G164-M92, Hot Dip Galvanizing of Irregularly Shaped Articles.12 CSA W186-M1997, Welding of Reinforcing Bars in Reinforced Concrete Construction.13 W , Certification of Companies for Fusion Welding of Steel Structures.14 ASTM A775/A 775M [94d], Specification for Epoxy-Coated Reinforcing Steel Bars..15 ASTM 412-[92], Test Method for Vulcanized Rubber and Thermoplastic Rubbers and Thermoplastic Elastomers - Tension.16 ASTM 2240-[95], Test Method for Rubber Property - Durometer.17 CAN/CGSB-1.40-[M89], Primer, Structural Steel, Oil Alkyd Type.18 CAN/CGSB [92], Ready Mixed Organic Zinc - Rich Coating.19 CAN/CGSB [M87], Thermal Insulation, Polystyrene, Boards and Pipe Covering 1.5 Qualifications of Manufacturer.1 Fabricate precast/prestressed concrete elements certified by the CSA International in the appropriate category(ies) according to CSA Standard A23.4 Precast Concrete - Materials and Construction. The precast concrete manufacturer shall be a member in good standing of the Canadian Precast/Prestressed Concrete Institute and shall be certified in accordance with the CSA Certification program for Structural Precast/Prestressed Concrete prior to submitting a tender and must specifically verify as part of his tender that he is currently certified in the appropriate category(ies): Spec Note: Delete the categories which do not apply. (A) Precast Concrete Products - Architectural (I) Non-Prestressed or (II) Prestressed (B) Precast Concrete Products - Structural (I) Non-Prestressed or (II) Prestressed (C) Precast Concrete Products - Speciality (I) Non-Prestressed or (II) Prestressed Only precast concrete elements fabricated by certified manufacturers are acceptable to the Owner. Certification must be maintained for the duration of the fabrication and erection for the project. Fabricate precast concrete elements in accordance with (Provincial) Building Code requirements..2 The structural precast/prestressed concrete manufacturer shall have a proven record and satisfactory experience in the design, manufacture and erection of structural units specified. The company shall have adequate financing, equipment, plant and skilled personnel to detail, fabricate and erect the work of this Section as required by the Specification and Drawings. The size of the plant shall be adequate to maintain the required delivery schedule. 1.6 By-Laws and Codes.1 Conform with applicable requirements of (Provincial) Building Code, National Building Code and local authorities having jurisdiction. Framing 24
25 Structural Specifications continued... Structural Precast/Prestressed Concrete.2 Design and provide reinforcement, anchors and supports as required by codes and to Consultant s approval. Submit relevant design data prepared by a professional engineer registered in the province of for approval if so requested by the Consultant. 1.7 Allowable Tolerances.1 Conform with requirements of CSA A23.4-Section Refer to related Sections of this Specification and fabricate work to accommodate the specified tolerances. 1.8 Source Quality Control.1 Make available copies of quality control tests related to this project as specified in CSA A Inspect prestressed concrete tendons in accordance with CSA A Make available records from in-house quality control program based upon plant certification requirements for inspection and review..4 Make available certified copy of mill test reports of steel reinforcement supplied, showing physical and chemical analysis..5 In addition to quality control, an independent inspection and testing company may be appointed by the owner to verify compliance with this Specification..6 Cooperate with Inspector to facilitate his work..7 Cost of an independent inspection is to be paid for by the owner. 1.9 Shop Drawings Spec Note: It is not the Precast Manufacturer s responsibility to confirm and correlate dimensions at the job site. Precast concrete is a prefabricated material. Site dimensioning would require the foundation/ structure to be complete before fabrication could commence..1 Prepare and submit shop drawings of precast/prestressed structural concrete elements in accordance with the General Conditions of the contract, CSA A23.4 and CSA A23.3, and as specified below. Submit in accordance with Section Submit fully detailed and dimensioned drawings showing and including but not limited to the following:.1 Design calculations for items designed by manufacturer..2 Typical details of prestressed and non-prestressed members, reinforcement and connections..3 Estimated Camber..4 Finishing Schedules..5 Methods of handling and erection..6 Openings, sleeves, inserts and related reinforcement..3 Show the exact location of inserts and anchors required to be cast into precast/prestressed units for interface elements..4 Show the system of identifying units for erection purposes on shop drawings and apply a similar mark on all units at the time of manufacture..5 Provide the Shop Drawings to obtain approvals from the Authorities having jurisdiction prior to fabrication of structural precast/prestressed units..6 If requested provide drawings of all precast members Finishes of Formed Surfaces.1 Finishes shall be (a) Commercial Grade, (b) Standard Grade, (c) Finish Grade B, or (d) Finish Grade A in accordance with clause 24 of CSA A23.4 as shown on the contract drawings..2 Finishes shall be (a) Commercial Grade, or (b) Standard Grade unless otherwise noted Warranty.1 Provide standard CPCI warranty with a duration of one (1) year in accordance with the General Conditions. Warranty shall be in writing and shall warrant work under this Section to be free from defects for the period stipulated. Framing 25
26 Structural Specifications continued Delivery, Storage and Protection.1 Accept full responsibility for delivery, handling and storage of units..2 Deliver, handle and store precast/prestressed units using methods approved by the manufacturer. Do not permit units to contact earth or staining influences or to rest on corners Design.1 Requirements: Design and fabricate precast/prestressed structural concrete elements, brackets and anchorage devices so that when installed they will:.1 Compensate for allowable construction tolerances in the structure to which they are secured..2 Tolerate a structural deflection of span/360 due to live load..3 Adequately sustain themselves, and superimposed loads, specified by the engineer, without exceeding deflection of 1/ Design loads shall be as specified by the (Provincial) Building Code. Spec Note: 1.14 applies to specifications for parking structures. Edit accordingly Special Surface Treatments.1 All anchors, plates, etc. exposed to the elements (less than 1½" concrete cover) to be hot dipped galvanized, except for inserts and treated items which shall be electro zinc plated..2 Hardware protected from exposure to the elements or by a minimum of 1½" concrete shall be shop coated with grey oxide primer..3 Double tee side weld plates, where exposed to the elements, shall be stainless steel. 2.0 Products 2.1 Materials.1 Reinforcing steel: to CSA A Forms: to CSA A Hardware and miscellaneous materials: to CSA A23.1. Spec Note: Re 2.1.4: Type 400W is weldable structural grade steel having a yield strength of 400 MPa. Refer to CSA G40.21 for other grades and yield strengths available..4 Anchors and supports: to CSA G40.21, Type [400] [(epoxy coated)(galvanized)(primed after fabrication)].5 Welding materials: to CSA W and CSA W186-[M1997]..6 Steel primer: to CGSB 1-GP-40M..7 Air entrainment admixture: to CSA A Bearing pads: neoprene, [60] durometer hardness to ASTM D2240, and [17] MPa minimum tensile strength to ASTM D412, moulded to size or cut from moulded sheet. (Random oriented fiber reinforced neoprene.).9 Shims: [plastic] [steel]..10 Zinc-rich primer: to CGSB 1-GP-181M..11 Surface retardant: to CSA A Concrete Mixes.1 Unless otherwise noted or specified, use concrete mix designed to produce a minimum of 35 MPa compressive cylinder strength at 28 days, with a maximum water/cement ratio to CSA A Use cement and supplementary cementing materials which conform to CSA A Air Entrainment of Concrete Mix: Refer to CSA A Use of calcium chloride not permitted. 2.3 Reinforcement and Anchors.1 Attach anchors securely in accordance with CSA W Galvanize anchors after fabrication and touch up anchors with zinc rich primer after welding..3 Reinforcing Steel: To CSA G30.16, CSA G30.12, CSA G30.18 [epoxy coated] Framing 26
27 Structural Specifications continued... Structural Precast/Prestressed Concrete 2.4 Fabrication.1 Fabricate precast/prestressed concrete units to CSA A Mark each precast/prestressed unit to correspond to identification mark on shop drawings for location..3 Mark each precast/prestressed unit with date cast..4 Cast members in accurate rigid moulds designed to withstand high frequency vibration. Set reinforcing anchors and auxiliary items to detail. Cast in anchors, blocking and inserts supplied by other Sections as required to accommodate their work. Vibrate concrete during casting until full thickness is reached. Provide necessary holes and sinkages for flashings, anchors, cramps, etc. as indicated. Separately and accurately batch cement and aggregates uniformly by weight to ensure maintenance of even and uniform appearance..5 Anchors, lifting hooks, shear bars, spacers and other inserts or fittings required shall be as recommended and/or designed by manufacturer for a complete and rigid installation. Each shall conform to requirements of local building By-Laws. Lift hooks shall be adequately sized to safely handle panels according to member dimension and weight. Anchors/inserts shall be concealed where practical..6 Burn off lift cables paint and fill in recesses if required. Spec Note: If special architectural finish is required for exposed structural precast import the appropriate paragraph from section Architectural Precast Concrete. Identify surfaces requiring these specific finishes. 2.5 Finishes.1 Finish units to [commercial grade] [standard grade] [finish grade A] [finish grade B] to CSA A23.4 Clause Parking Structures.1 Precast/prestressed floor and roof units shall be double tee components with prestressed reinforcement as required by design. The finish of the underside of the double tees shall be a standard form finish..2 Precast beams and columns shall be of the dimensions shown on the drawings with prestressed and/or non-prestressed reinforcement. Architectural finish and colour: (specify) A grey cement, standard form finish..3 Precast spandrel panels shall have a profile and thickness as shown on the drawings. Architectural finish and colour: (specify) A grey cement, light sandblast finish for the exterior surfaces exposed to view. The exposed interior surface of spandrel panel shall have a standard wood float finish..4 All other structural components shown on drawings shall have a grey cement, standard form finish..5 Prestressing tendons shall be uncoated 7 wire strands conforming to CSA Standard A Double Tee Slab Units.1 Precast/prestressed floor and roof units shall be double tee components with prestressed reinforcement as required by design. The finish of the underside of the double tees shall be a standard form finish..2 Prestressing tendons shall be uncoated 7 wire strands conforming to CSA Standard A Structural Framing Units.1 Type: Precast/prestressed concrete structural framing units..2 Furnish units free of voids or honeycombs..3 Provide standard finish to precast units..4 Where ends of strands will not be enclosed or covered, cut flush and cover with a high-strength mortar bonded to unit with an epoxy-resin bonding agent..5 Reinforce units to resist transportation and erection stresses..6 Include cast-in weld plates where required..7 Coordinate with other trades for installation of cast-in items. Framing 27
28 Structural Specifications continued... Structural Precast/Prestressed Concrete 3.0 Execution 3.1 General.1 Erect precast/prestressed work in accordance with CSA A23.4. Spec Note: It is not the Precast Manufacturer's responsibility to confirm and correlate dimensions at the job site. Precast concrete is a prefabricated material. Site dimensioning would require the structure to be complete before fabrication could commence..2 Supply anchors for precast units required to be cast into cast-in-place concrete frame to Contractor for installation. Provide such items in ample time to meet construction program. Supply layout drawings locating accurately the position of all cast in items to be installed by other Sections. 3.2 Installation.1 Set precast/prestressed concrete units, straight, level and square..2 Do welding in accordance with CSA W59, for welding to steel structures and CSA W186, for welding of reinforcement. Spec Note: Select one only of the two following paragraphs..3 Erect precast/prestressed elements within allowable tolerances as [indicated] [specified]..4 Non-cumulative erection tolerances to be in accordance with CSA A23-4, Section [10]. Spec Note: Where bearing pads are required, specify locations if not clearly indicated on drawings..5 Set elevations and alignment between units to within allowable tolerances before connecting units. Spec Note: Check if required. Do not grout under elastomeric pads..6 Grout underside of precast units with shrinkage compensating grout where indicated..7 Secure with bolts using [lockwashers] [or] [tack-weld nut to bolt]..8 Do not weld or secure bearing plates at sliding joints..9 Use grout to align elevations at surface of joints in situations where allowable tolerances have been exceeded or as noted on consultants drawings in critical locations..10 Clean field welds with wire brush and touch-up [shop primer with primer] [galvanized finish with zinc-rich primer]..11 Fasten units in place as per approved connection detail shop drawings. Protect work from damage by weld splatter..12 Clean field welds with wire brush and touch up with galvafroid paint or zinc rich primer. 3.3 Handling and Erection.1 Precast/prestressed components shall be handled and erected in accordance with CSA Standard A23.4 and as per the manufacturer's instructions..2 Precast/prestressed components shall be delivered and handled in such a manner as to avoid warpage..3 Holes and reglets shall be protected from forming of ice during freezing weather..4 Lifting devices shall be protected from rusting at all times..5 All precast/prestressed components shall be erected by experienced workmen under the supervision of a qualified superintendent with a minimum of five (5) years experience..6 Welding of the precast units shall be performed by certified welders in accordance with CSA Standard A23.4, Clause Units shall be set plumb and true with joints parallel and uniform..8 All necessary precautions shall be taken to prevent weld burn or splatter on to exposed surfaces..9 Patch damaged, or chipped components as required. 3.4 Cleaning.1 If required, clean exposed face work by washing and brushing only, as precast is erected. Use approved masonry cleaner if washing and brushing fails to achieve required finish. Remove immediately materials which may set up or harden. This section is not responsible for soiling or damage by others. End of Section Framing 28
29 Structural Precast/Prestressed Concrete Long Span Parking Garages Parking structures often represent the first and last impression a visitor has when visiting a facility. Excellent parking structures are designed specifically for the types of visitors a structure will serve. Unless a parkade is safe, secure and easy-to-use, parkers will find other options. Creating the best parking structure to fit the site requires a careful balance of all elements and a logical plan from start to finish. The involvement of your local CPCI member from the beginning while key design decisions are being made can make a dramatic difference to the final result. Their expertise and input can minimize the time and cost required to complete a project. Precast parkades offer fast construction, versatility of design, attractive exterior finishes, durability and economy making precast prestressed concrete a popular choice for commercial, municipal and institutional clients. Exterior Finishes Precast parking garage exteriors can be delivered with a wide range of shapes and finishes ranging from smooth dense structural units to any number of architectural treatments. Loads and Forces Precast concrete parking structures allow for volume changes from creep, shrinkage and temperature differences. Components are cured before they are delivered to the site. The connections between members allow the structure to relieve pressures from ordinary expansion and contraction that otherwise could cause cracking in structural elements. Lateral design loads for wind, earthquake or earth can be resisted in a precast concrete structure by transferring loads through the floor diaphragm to shear walls and/or to column beam frames. Care in locating and the isolation of shear walls and isolation (expansion) joints will assure performance. Loading walls with framing beams or floor members can minimize connections between shear walls to resist uplift forces. Connections can be designed to prevent beam rotation and absorb bumper loads without undue restraint against volume changes. 29
30 Bay Sizes For maximum economy, bay sizes should be as large as practical and modular with the standard precast concrete floor elements selected. For long span parking, the bay size selected need not be a multiple of the width of the parking stall. Clear spans with fewer columns create an open concept for added security. Drainage Sloping the floors to achieve good drainage is essential to quickly remove rain and salt laden water from the structure. The drainage pattern selected should repeat for all floors wherever possible to allow for repetition in manufacturing the precast elements. Locate isolation (expansion) joints at high points to minimize possible leakage. Slope the floors away from columns, walls and spandrels to promote proper drainage. Durability High strength precast concrete components are cast under controlled conditions in the precaster s plant. When precast concrete elements are prestressed, concrete is cast around highly tensioned pretensioning strands that run through the steel forms. After the concrete has cured, the pretensioning force is released into the beam placing the concrete in compression. Prestressed slabs and beams are virtually crack-free and highly resistant to attack by chloride ions Where cast-in-place composite topping is used over precast floor members, wire mesh reinforcement should be incorporated in the topping. A high strength concrete topping having a water cement ratio of 0.40 or less, 6% entrained air and five days of curing under wet burlap will produce the best results (see CSA S413). A series of crack control joints should be tooled into the topping above all joints in the precast members below. A V-shaped trowel will produce a 25 mm deep by 12 mm wide joint. Later these joints are prepared by grinding with a V-shaped abrasive wheel and filled with a polyurethane sealant. Pretopped double tees are a recommended alternative to field-placed concrete toppings. This system has excellent 35 to 55 MPa plant produced wearing surface - broom-finished to provide improved driving traction. Standard details are used for adjacent camber differential, joint treatments, erection stability and drainage with this system. Except for column base plates, all connections and exposed hardware often use hot dipped galvanized or stainless steel. Where connections are subsequently welded, the welds should be minimal and located where they can be easily maintained. Garages 30
31 Column Base Detail Inverted T/Beam to Column Connection All connections shown are to be used for concept design only. Inverted T/Beam to Double Tee Connection Column Wall to Double Tee Connection Garages 31
32 Non Load-Bearing Spandrel To Double Tee Connection Load-Bearing Pocketed Spandrel To Double Tee Connection All connections shown are to be used for concept design only. Load-Bearing Ledged Spandrel To Double Tee Connection Crack Control Double Tee Joints Garages 32
33 Pre-Topped Double Tee Typical Details (for concept only) LB Spandrel to Pre-Topped Double Tee Connection NLB Spandrel to Pre-Topped Double Tee Connection Pre-Topped Double Tee Joint Pre-Topped Double Tee to Inverted T/Beam Connection Column Wall to Pre-Topped Double Tee Connection Garages 33
34 Structural Precast/Prestressed Concrete Specialized Uses Precast rakers for custom stairs. Precast stadium arena/theatre seating. Precast stairs. 34
35 Sound barrier walls. Custom precast rings for chimney stacks. Storage and holding tanks. Hotels. Interior fire walls. Tunnel liners. Specialized Uses 35
36 Structural Precast/Prestressed Concrete Bridges Long spans require fewer piers allowing improved navigation. All weather construction ensures schedules are met. Precast requires no painting, minimizing long term maintenance costs. Precast/Prestressed girders eliminate shoring work. 36
37 Plant cast girders are quickly placed during off-peak times, minimizing traffic interruption. Standard girder sections minimize engineering and manufacturing time, resulting in quick product availability. Bridges 37
38 Structural Precast/Prestressed Concrete Heavy Industrial Precast construction is the answer for heavy industrial projects. Precast framing and cladding can be cost effective both on first cost and when considering life cycle cost projections. Applications Precast Concrete can be used for most heavy industrial applications - specialty and machine buildings (pulp and paper mills, wash buildings, control buildings), food processing, pipe racks, equipment slabs, environmental containment, mat foundations, piles, rotating equipment foundations and more. Speed Fast construction means earlier production, occupancy and reduced financing costs. Winter construction can proceed with few weather delays. Precast components are prefabricated off-site in heated plants and delivered to the jobsite when needed. 38
39 Easy Maintenance Precast components require little maintenance. Precast concrete resists abrasion, weathering and many harsh chemicals. Precast can withstand washdown, thermal shock and high-pressure hose streams. Fire Resistance Precast concrete is noncombustible and has inherent fire resistance. Precast members can be designed to provide the required fire protection. Precast construction protects occupants and building contents from fire. Pulp & Paper Mill. Fire damage and downtime is usually minimal in the event of a fire. Many insurance companies recognize this and provide lower rates. Insulated panels. Precast Panel Systems Precast sandwich wall panels are ideal for industrial applications. Panels can be provided with insulation values to suit your requirements. Exterior and interior finishes can be smooth, coloured or textured. Panels can be relocated later on to accommodate building expansions. Integration Precast pipe racks. Precast structures can accommodate most equipment, cranes, monorails, mechanical systems and electrical systems. Often a modular grid of openings and sleeves or inserts is provided for flexibility and to allow for ongoing changes during construction and for future modifications to the building/processes. Heavy Industrial 39
40 For More Information: CPCI Design Manual, Third Edition order from Canadian Precast/ Prestressed Concrete Institute 196 Bronson Avenue, Suite 100, Ottawa, Ontario K1R 6H4 Telephone (613) Fax: (613) Toll Free: YES-CPCI ( ) Web: DISCLAIMER: Substantial effort has been made to ensure that all data and information in this publication is accurate. CPCI cannot accept responsibility of any errors or oversights in the use of material or in the preparation of engineering plans. The designer must recognize that no design guide can substitute for experienced engineering judgment. This publication is intended for use by professional personnel competent to evaluate the significance and limitations of its contents and able to accept responsibility for the application of the material it contains. Users are encouraged to offer comments to CPCI on the content and suggestions for improvement. Questions concerning the source and derivation of any material in the design guide should be directed to CPCI.
SPECIFICATION Section 03410 - Structural Precast / Prestressed Concrete
Lafarge/CPCI Guide Specification SPECIFICATION Section 03410 - Structural Precast / Prestressed Concrete 1.0 General 1.1 Description.1 The General conditions of the Contract and Supplementary General Conditions
SPECIFICATION Section 03450 - Insulated Precast Concrete Wall Panels
Lafarge/CPCI Guide Specification SPECIFICATION Section 03450 - Insulated Precast Concrete Wall Panels 1.0 General 1.1 Description.1 The General conditions of the Contract and Supplementary General Conditions
Precast Concrete Insulated Sandwich Wall Panels
Precast Concrete Insulated Sandwich Wall Panels Technical Brochure Canadian Precast/Prestressed Concrete Institute Precast Concrete Insulated Sandwich Wall Panels Insulated precast concrete panels provide
Total Precast. Concrete Structures. Canadian Precast/Prestressed Concrete Institute. Technical Brochure
Total Precast Concrete Structures Technical Brochure Canadian Precast/Prestressed Concrete Institute Table of Contents Total Precast Concrete Structures...4 Long Span Parking Garages...12 Residential Buildings...18
SECTION 03400 PRECAST CONCRETE STRUCTURES
SECTION 03400 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for precast concrete structures, including fabrication and erection. 1.02 REFERENCE STANDARDS A. American Society for
4B-2. 2. The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.
Shear Walls Buildings that use shear walls as the lateral force-resisting system can be designed to provide a safe, serviceable, and economical solution for wind and earthquake resistance. Shear walls
TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE
TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION PART 8000 - PRECAST CONCRETE TABLE OF CONTENTS Item Number Page 8100 PRECAST CONCRETE CONSTRUCTION - GENERAL 8-3 8101 General
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
SECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec 03500 Master Spec. 03 49 00 Page 1
C. S. I. Spec 03500 Page 1 PART 1 - GENERAL 1.01 SUMMARY:.01 Provide special glassfiber reinforced cement (GRC) shapes in accordance with the requirements of the contract documents..02 The installing contractor
Wastewater Capital Projects Management Standard Construction Specification
CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,
Safe & Sound Bridge Terminology
Safe & Sound Bridge Terminology Abutment A retaining wall supporting the ends of a bridge, and, in general, retaining or supporting the approach embankment. Approach The part of the bridge that carries
Example Specification for Concrete using Current Building Code Requirements
Example Specification for Concrete using Current Building Code Requirements DISCLAIMER: This specification is an example that accompanies a seminar titled The P2P Initiative: Performance-based Specs for
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION
CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION General 7 www.meadowburke.com 877-518-7665 MB1109 CONCRETE FLOOR SLAB AND CASTING BED CONSTRUCTION Quality Construction Begins at Ground Level Everything
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections
Materials Standard shapes W sections, C channels, Structural T, Angles, Pipes, Tubes, Rods and Plates Fabricated members, Built-up sections Adding plates to beam flanges, Stiffeners to beam webs Built
SECTION 1 GENERAL REQUIREMENTS
Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,
Precast Concrete Parking Structures
Precast Concrete Parking Structures Durability starts at the joints BY DAVID C. MONROE AND JOSEPH L. WHITE Parking structures comprise the largest market segment for the structural precast, prestressed
Hanson Building Products. precast basement solutions
Hanson Building Products precast basement solutions Hanson Building Products Basement Systems Add an extra dimension and combine the inherent flexible, structural and waterproof properties of concrete
SPECIAL INSPECTION AND TESTING AGREEMENT INTERNATIONAL BUILDING CODE
Community Development Permit Services SPECIAL INSPECTION AND TESTING AGREEMENT INTERNATIONAL BUILDING CODE PROJECT NAME PROJECT ADDRESS PERMIT NUMBER CITY RECEIVED STAMP AND INITIALS Instructions: BEFORE
Detailing of Reinforcment in Concrete Structures
Chapter 8 Detailing of Reinforcment in Concrete Structures 8.1 Scope Provisions of Sec. 8.1 and 8.2 of Chapter 8 shall apply for detailing of reinforcement in reinforced concrete members, in general. For
EAST LYME HIGH SCHOOL
Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed
Preformed Metal Roofing and Siding
Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision
SECTION 33 05 16.13 PRECAST CONCRETE UTILITY STRUCTURES
SECTION 33 05 16.13 PRECAST CONCRETE PART 1 - GENERAL 1.01 SECTION INCLUDES A. This item shall consist of the construction of both sanitary and storm sewer precast concrete manholes in accordance with
Architectural Precast Concrete Technical Brochure
Architectural Precast Concrete Technical Brochure Canadian Precast/Prestressed Concrete Institute 2 Introduction The Canadian Precast/Prestressed Concrete Institute is proud to provide you with this brochure
COMMONLY USED RESIDENTIAL BUILDING CODES
COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section
PART E SPECIFICATIONS
PART E SPECIFICATIONS Page 1 of 5 PART E - SPECIFICATIONS GENERAL E1. APPLICABLE SPECIFICATIONS, STANDARD DETAILS AND DRAWINGS E1.1 The City of Winnipeg Works and Operations Division Standard Construction
Mark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
LAYING BLOCK AND BRICK
LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct
SECTION 05 7360 ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS
1 SECTION 05 7360 ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and
SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries Introduction Wastewater of petrochemical industries and refineries contains high amounts of emulsified aliphatic or
September 1, 2003 CONCRETE MANUAL 5-694.900 CONCRETE PAVEMENT REHABILITATION 5-694.900
September 1, 2003 CONCRETE MANUAL 5-694.900 5-694.901 GENERAL CONCRETE PAVEMENT REHABILITATION 5-694.900 Concrete Pavement Rehabilitation is an extremely valuable tool of the Minnesota Department of Transportation
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical
Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI 318-14
Draft Table of Contents Building Code Requirements for Structural Concrete and Commentary ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318 14) Chapter 1 General 1.1 Scope of ACI 318
1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated.
CAST IN PLACE DETECTABLE/TACTILE WARNING SURFACE TILE PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Special Conditions and Division 1 Specifications
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major
Contractor s Statement of Responsibility for Seismic-Force-Resisting Systems This form is to be filled out by the contractor.
SPECIAL INSPECTION PROCEDURE IBC CHAPTER 17 2012 EDITION When Required All projects that require a SC licensed Architect or Engineer per SC Architectural and Engineering registration law. Overview The
Acceptance Codes APPENDIX - A. Acceptance Criteria
1111 Receipt of a satisfactory Test Report from WSDOT Materials Laboratory is required indicating the lot (or lots) or batch of material meets the requirement of the specifications under which it is listed.
Guide Specification Precast Concrete Products
Guide Specification Precast Concrete Products This specificaton should be used only by qualified professionals who are competent to evaluate the significance and limiations of the specification and who
Concrete Specification for Cooling Tower and Basin
Concrete Specification for Cooling Tower and Basin 1.0 SUMMARY Includes: 1. Structural Capabilities 2. Fabrication Tolerances 3. Placing, finishing and curing ready-mix concrete. 4. Formwork, complete
CCU Engineering Specifications. Section 003300 PRECAST CONCRETE PRODUCTS
CCU Engineering Specifications Section 003300 Effective Date: Nov. 1st, 2011 Page 1 of 5 PRECAST CONCRETE PRODUCTS PART 1 - GENERAL The following specification is intended for use for the design, selection
CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS
AN ERGONARMOR COMPANY TECHNICAL INFORMATION SPECIFICATION FOR INSTALLATION 07/11 SUPERSEDES 04/00 PAGE 1 OF 6 CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS 1. SCOPE 1.1 This specification
TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks 174.6 FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.
Pages identified with the NMBS Logo as shown above, have been produced by NMBS to assist specifiers and consumers in the application of New Millennium Building Systems Deck products. Pages identified with
MANUFACTURED HOUSING USED AS DWELLINGS
MANUFACTURED HOUSING USED AS DWELLINGS SECTION AE101 SCOPE AE101.1 General. These provisions shall be applicable only to a manufactured home used as a single dwelling unit and shall apply to the following:
DESIGN OF PRESTRESSED BARRIER CABLE SYSTEMS
8601 North Black Canyon Highway Suite 103 Phoenix, AZ 8501 For Professionals Engaged in Post-Tensioning Design Issue 14 December 004 DESIGN OF PRESTRESSED BARRIER CABLE SYSTEMS by James D. Rogers 1 1.0
CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS
CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS 1.0 DESIGN 1.1 Scope of Work 1.1.1 This work shall consist of furnishing Isolation Bearings and installing Isolation Bearing Assemblies at the locations
PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE
FORM A PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE The following suggested specifications are written as a guide to assist the specifier in writing his own specifications. Specific circumstances
1.02 SYSTEM DESCRIPTION
1 OF 7 MODULAR MEZZANINES GUIDE SPECIFICATIONS FOR PART 1 - GENERAL 1.01 RELATED WORK A. SECTION 03 30 00: Cast in Place Concrete (and Concrete Finishing) 1. The area where mezzanine is installed shall
GUIDE SPECIFICATIONS FOR PRECAST CONCRETE PRODUCTS
GUIDE SPECIFICATIONS FOR PRECAST CONCRETE PRODUCTS PART 1 - GENERAL 1.1 SECTION INCLUDES A. This specification covers the materials for and manufacture of precast reinforced concrete units produced in
Certification: Building Plans Examiner. Exam ID: B3
Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building
NAPCA BULLETIN 18-99 APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE
NAPCA BULLETIN 18-99 APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE GENERAL a. These specifications may be used in whole or in part by any party without
Code of Standard Practice for Timber Frame Structures
TFEC 2-2013 Code of Standard Practice for Timber Frame Structures August 2013 Preface This Code is intended to represent a reasonable consensus of what constitutes ordinary and acceptable practice within
Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training
Foundations 65 5 FOUNDATIONS by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. 66 Foundations Foundations 67 FOUNDATIONS Let's assume that the retrofit has been done correctly from the roofline
FUTURE SLAB. PENETRATIONS and. DEMOLITION of POST-TENSIONED FLOORS
FUTURE SLAB PENETRATIONS and DEMOLITION of POST-TENSIONED FLOORS 1.0 INTRODUCTION Post-tensioned floor slabs in Australia and South East Asia are now universally regarded as the most cost effective form
PTFE Slide Bearings 04/10 149
04/10 149 1.0 GENERAL INFORMATION In a wide range of applications, PTFE Slide bearings are superior to conventional expansion plates, rollers and rocker arm type supports. They support petrochemical plant,
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER
1.2 Advantages and Types of Prestressing
1.2 Advantages and Types of Prestressing This section covers the following topics. Definitions Advantages of Prestressing Limitations of Prestressing Types of Prestressing 1.2.1 Definitions The terms commonly
6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders
Structural Foundation System
Structural Foundation System SLABTEK, a technological advancement in foundation designs for residential and lightweight commercial structures SlabTek is a patent allowed process for concrete foundations
VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10
VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10 SECTION B1: PREPARATION GUIDE B1.1 INTRODUCTION... B1-1
Fabcograte FRP Grating. Tolerances: ±1/16. Tolerances: ±1/16. THICKNESS BAR SPACING PANEL SIZE (FT.) WT (LBS) 1" 1.5" x 1.
Features: Will not rust. Corrosion resistant. Non-sparking. Fire retardant. Non-conductive. Maintenance free. Molded-in color. Light weight. Easy to install. Impact resistant. Quality appearance. Fabcograte
7. Installation. installation 7.1.1. CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME
7. Installation Window involves the fixing of window frame at an earlier construction stage and subsequent of the window sashes. This is a highly workmanship dependent process. Only trained and approved
necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the
Chapter 7 PLUMBING AND ELECTRICAL 7.1 Introduction to Plumbing and Electrical Consideration of support services such as plumbing and electrical systems from the preliminary schematics phase through final
Elevating Your House. Introduction CHAPTER 5
CHAPTER 5 Elevating Your House Introduction One of the most common retrofitting methods is elevating a house to a required or desired Flood Protection Elevation (FPE). When a house is properly elevated,
HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
Design and Construction of Cantilevered Reinforced Concrete Structures
Buildings Department Practice Note for Authorized Persons, Registered Structural Engineers and Registered Geotechnical Engineers APP-68 Design and Construction of Cantilevered Reinforced Concrete Structures
Uniform Construction Code (UCC) Manufactured Homes. Modular Homes. Building Permit Application Package
Uniform Construction Code (UCC) Manufactured Homes (Single-Wide, Double-Wide) Modular Homes Building Permit Application Package Per the Uniform Construction Code (UCC) all structures must be built per
The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.
26 D+D MARCH 2015 Building Envelope Roland Serino, P.E., Dryvit Systems Inc. here has always been a need for a more efficient way to build in large cities like Chicago, New York, Los Angeles or other central
LEGACY REPORT. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council. *Corrected March 2014
ICC-ES Legacy Report PFC-3700* Issued October 2003 www.icc-es.org (00) 423-57 (52) 99-0543 A Subsidiary of the International Code Council Legacy report on the 1997 Uniform Building Code and the 2000 International
Excerpts from the Canadian National Building Code (NBC)
Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more
Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing
1 Most basements show some signs of leaking and cracking. Through the years, problems with water, poor soils, grading, drainage and possible settling affect the integrity of a basement. Being able to recognize
Section 02702 SEWER PIPE INSTALLATION AND TESTING
PART 1 - GENERAL Section 02702 SEWER PIPE INSTALLATION AND TESTING 1-1. SCOPE. This section covers the installation and testing of all sewer pipe furnished under the following specification sections: Concrete
Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations
Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations Nathan A. Ingraffea, P.E., S.E. Associate, KPFF Consulting Engineers, Portland, Oregon, USA Abstract The use of steel sheet
Embedded Parts Introduction - Anchors
In the plant construction or process plants such as chemical, petrochemical, gas or power plants various disciplines are brought into contact and built on each other. Civil, mechanical, electro technical
cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement
cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement Lafarge in North America The Lafarge Group is the world leader
9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.
Section 9.8. Stairs, Ramps, Handrails and Guards 9.8.1. Application 9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and
Dubai Municipality Standard DMS 1: Part 5: 2004
Specification for precast concrete blocks Part 5: Normal-weight concrete-polystyrene sandwich masonry blocks Issue Date Revision Revision Description Prepared by Approved by Authorized by 19/12/2004 Issue
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24, 2014 06610-1
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING January 24, 2014 06610-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED GRATING PART 1 - GENERAL 1.1 SCOPE OF WORK A. The CONTRACTOR
Section 8.1 Volume I QUALITY ASSURANCE PROGRAM OF PRECAST PRESTRESSED CONCRETE PRODUCTS
Section 8.1 Volume I QUALITY ASSURANCE PROGRAM OF PRECAST PRESTRESSED CONCRETE PRODUCTS 8.1.1 PURPOSE This procedure provides guidelines related to the implementation of quality control and quality assurance
SECTION 11014 WINDOW WASHING SYSTEMS
SECTION 11014 WINDOW WASHING SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes, but is not limited to, design and furnishing portable davits, davit sleeves, dvit bases, four (4) removable outriggers,
1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona
for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES
1.00 PART 1 GENERAL 1.01 SCOPE A. It is the intent of this contract to install a 100% solids epoxy monolithic coating to the walls, benches and inverts of all manholes and the specified surfaces of other
Page & Turnbull imagining change in historic environments through design, research, and technology
DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED
SECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,
Chapter 5 Bridge Deck Slabs. Bridge Engineering 1
Chapter 5 Bridge Deck Slabs Bridge Engineering 1 Basic types of bridge decks In-situ reinforced concrete deck- (most common type) Pre-cast concrete deck (minimize the use of local labor) Open steel grid
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES 1 PART 1 - GENERAL 1.0 GENERAL 1.1 REFERENCES: SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED FIBERGLASS
Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS
MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS May 29, 2013 Revision B Structural Guideline for Design and Installation Holes in Composite Floor Slab Terminal 3, Departure Level
GUIDELINE SPECIFICATIONS
GUIDELINE SPECIFICATIONS GORDON SOFFIT-SHIELD - An Exterior Metal Soffit System DIVISION 05 5800 or DIVISION 07 7700 Note To Specifier: SOFFIT-SHIELD should be installed by tradesmen that are experienced