Temperature Sensors. General. Specification. Description
|
|
|
- Cassandra Barber
- 9 years ago
- Views:
Transcription
1 Description Temco Controls manufactures temperature sensors for the air conditioning industry. This document shows the enclosures and temperature vs. resistance curves for the standard sensors. General The sensors employ precision interchangeable thermistors and RTD which are compatible with all the major building automation systems. Designed for temperature sensing in an HVAC and light industrial control applications. Precision interchangeability eliminates the necessity for individual circuit calibration. Data sheets for the standard items appear on the web at Temco is able to produce custom sensors in small volume at standard sensor pricing. There are several sensor element ranges to choose from, which guarantee compatibility with all popular DDC systems. The sensor elements are precision thermistors or platinum RTDs. Field calibration is not generally required. The probe is epoxy sealed to prevent moisture from migrating into the probe. Custom probe lengths, wire types and sensor elements are available for large OEM projects. Ask about our plastics & metal manufacturing capabilities for custom housings as well. Part # Suffix Sensor Typical User ohm Platinum 3-wire Honeywell 5 1,801 ohm Thermistor t.a.c. / CSI 6 3,000 ohm Thermistor Alerton -7 10,000 ohm Thermistor Type2 Trane, Automated Logic, Temco, t.a.c., CSI, Solidyne, Alerton 9 100,000 ohm Thermistor Siemens(Landis & Staefa) 11 LM334 IC sensor t.a.c. / CSI ohm Platinum ohm Nickel Johnson Controls 20 20,000 ohm Thermistor Honeywell 21 LM335 IC Sensor Solidyne, IECC ,000 ohm Therm, Type 3 Specifications: Sensor Property Thermistor Accuracy Platinum RTD Accuracy Specification +/- 0.2 C +/- 0.4 C Thermistor Range -70 C to 150 C Platinum RTD Range -200 C to 300 C Probe Material Cable Properties Invensys(siebe), Honeywell, Johnson Controls, Siemens (Landis & Staefa) Andover, AAM, Teletrol, Invensys(Siebe), Multinet, Delta, Carrier, KMC, Temco Stainless Steel FT4, 80 C, 600V
2 Duct Temperature Sensor Plastic Water Resistant Box: Metal Electrical Box: Dimensions(mm): - 2 -
3 Ordering Information: - 3 -
4 DTS-FL: Flange Mount Duct Temperature Sensor Descriptions: This sensor is used to measure the supply and return temperature in HVAC system. The flange mount design makes it easy to install the sensor in tight quarters. There are several sensor elements to choose from which guarantee compatibility with all popular DDC systems. The probe in the photo is out standard model which is always in stock, it has a 8 inch probe and 6 inch long cable, and employs either a precision thermistor or platinum film sensor field calibration is not generally required. The 10ft(3m) cable is plenum rated. Contruction: The sensor is a high quality unit manufactured to high standards, using materials and assembly techniques. The probe material is stainless steel with a welded and ground tip.the DTS probe is baked and then epoxy sealed to eliminate long term moisture problems. The flange accepts two #6 screws, and is made from glavanized steel. Ordering Information: - 4 -
5 OAT: Outside Air Temperature Sensor Descriptions: This sensor is used to measure the outside air temperature to allow the DDC system to coordinate the mechanical systems with actual building load conditions, enabling such strategies as free cooling, optimum start / stop, and supply temperature reset. The housing is made from PVC electrical fittings which shield the probe from direct sunlight. The probe is manufactured to industrial standards. There are three thermistor based models, and one RTD version to provide compatibility with the majority of DDC systems. The sensors are accurate enough that calibration is not usually required. Specifications: Sensor Property Thermistor Accuracy Platinum RTD Accuracy Thermistor Range Probe Material Cable Properties Specification ±0.2 O C ±0.4 O C -40 ~ 120 O C Stainless Steel FT4, 80 O C, 600V Contruction: The sensor probe is made from stainless steel which is welded, ground down, and finally pressure tested before assembling. The probe is then baked and epoxy sealed to provide long term protection from moisture. The sensor housing is a PVC electrical enclosure which is UL approved for outdoor use. The housing extends over the probe to protect from sunlight radiation. The sensor lead extends 12 from the enclosure, making it long enough to reach a junction box and terminate inside the building. The thermistor models are accurate to 0.2 O C while the platinum RTD is accurate to 0.5 O C. Installation: The OAT sensor can be mounted on the outside of the building using the following guidelines: Choose a spot on the north face which will be out of sunlight for as much of the day as possible. Mount the sensor where it can be serviced, staying away from exhaust ducts. Point the probe downwards to avoid catching rain. To install the sensor, drill a 3/4 (20mm) hole through the wall, and pipe the sensor to an electrical junction box on the inside of the wall. The sensor has a female 1/2 NPT threaded fitting to accept a short length of 1/2 pipe or PVC. Two conductors are required, 18ga, unshielded twisted pair is common
6 Ordering Information: *Thermistors,pt elements and probe sizes for all popular control systems are available,send us an if you don t see what you need online
7 OAT: Outdoor Air Temperature Sensor Features General purpose outdoor air temperature sensor Available in threaded PVC version with rugged weatherproof electrical box Easy installation - just threads into mounting hole or standard handy box installation Fully potted metal housing protects sensing element and provides fast, accurate temperature sensing Cost efficient design Sturdy construction - all plastic housing with PVC solar shield with optional weatherproof electrical box Description The temperature sensor is designed to measure outdoor air temperature. The sensor isdesigned for mounting in a standard ½ knock out.the temperature sensor uses a 10K Ω thermistor. The thermistor is enclosed in a plastic housing.the sensor has a short 20AWG black leads. It is designed for use in residential and commercial building automation controls. It features a fast response, precision thermistor sensing element that is totally sealed against the outdoor elements. The PVC sun-shield prevents false readings from direct sunlight. An optional weatherproof electrical box allows for simple installation and provides an extra rugged and reliable sensor for energy management and HVAC applications. Dimensions(mm) - 7 -
8 OAT: Outdoor Air Temperature Sensor Table 1: Lead Wiring (20 AWG, 6 in.) Color Code Sensor Type Lead Color Resistance Chart 10k ohm Thermistor White 1k ohm Platinum White 3k ohm Thermistor White 10k ohm Type II Thermistor White 10k ohm Type III Thermistor White The accuracy of the resistor can be verified using an Ohm meter. The chart below shows the resistance for various temperatures. Temperature (ºF) Temperature (ºC) Resistance (Ohms) , , , , , , , , , , , , , , , , , , , , , , ,
9 OAT: Outdoor Air Temperature Sensor Ordering Information: *Thermistors,pt elements and probe sizes for all popular control systems are available,send us an if you don t see what you need online
10 Room Temperature Sensor RTS: Room temperature sensor, 10K type 2 RTS1: Tamper proof room temperature sensor, 10K type 2 RTS3: Flush mounting sensor, 10K type
11 WTS Series Water Temperature Sensor WTS-MO: WTS-WP: WTS-M1: WTS-P: Outdoor Rated Watertight Plastic Metal Probe Only Installation: Locate water temperature sensor at least a few pipe diameters downstream any heat or cooling source: A 1/2 NPT female pipe fitting is welded into the pipe. These fittings are usually supplied and installed by the piping trade under direction of the controls trade. Choose an orientation where any condensation will not collect, such as the top of a horizontal pipe section or at a 45 angle from horizon. Before threading the sensor into the well, deposit some thermal paste in the bottom of the well to improve heat conduction between the metal parts. The sensor is wired with two conductors, normally 18ga unshielded twisted pair. Ordering Information:
12 WTS5 Series Strap on Water Temperature Sensor WTS5-WP: WTS5-M1: Installation: For measuring water temperature, the probe is strapped with plastic tie wraps or a metal strap onto the outside of the pipe and covered with insulation. The electrical box is mounted on a strut bar or on the wall near the pipe. Two conductors are required, 18ga, unshielded twisted pair is common. Ordering Information:
13 RTS-Raw 10K NTC Thermistor, Temco s standard thermistor element Specifications: Rated Resisitance: R25=10.00KΩ±1% B-Value: B25/50=3950Ω±1% OperatingTemperature: -40 ~ +120 C Dimensions (mm): 1: TC39B103F 2: Epoxide Resin, Clear 3: Ø0.5mm Tinned Copper Wire RTS-Bead-4: Thermistor bead, 4 (10cm) lead, 10mm wire trimmed and tinned, 0.2DegC accuracy Specifications: Zero Power Resistance: R25=10.00kΩ ±1% B-Value: B25/50=3950K ±1% Operating Temperature Range: -40 ~ +120 C Insulated Resistance: 500VDC in water, >100M Ω Breakdown Voltage: 1500VAC in water, 1 minute. No flash over (Leak Current: 1mA Max). Dimensions (mm): 1: TC39B103F 2: EPOXY RESIN 3: UL /2CAWG 105 C Black Wire
14 PRB Temperature Sensor: 0.6 SS probe temp sensor, 10K thermistor, Type 2 Temperature Sensors Specifications: Nominal Resistance: R25=10.00kΩ±1% B Value: B25/50=3950K±1% Optimal Operating Temperature Range: -40 ~ +120 C Insulated Resistance: 500VDC in water, >100MΩ Breakdown Voltage: 1500VAC, 1min. Dimensions (mm): 1: TC39B103F 2: Ø5x15 Stainless Steel 3: UL /2CAWG 105 C Black Wire Ordering Information:
15 PRB Temperature Sensor: ID6 X 50mmprobe temp sensor, 10K thermistor, Type 2 Temperature Sensors Specifications: Nominal Resistance: R25=10.00kΩ±1% B Value: B25/50=3950K±1% Optimal Operating Temperature Range: -40 ~ +120 C Dimensions (mm): 1: Ø6x50 Stainless Steel 2: UL /2CAWG 105 C Black Wire Ordering Information:
16 PRB Temperature Sensor: ID6mm X 200mm probe temp sensor, 1K Platinum thermistor Specifications: Nominal Resistance: R25=1000Ω±1% B Value: 1000Ω±1% Optimal Operating Temperature Range: -200 ~ +400 C Platinum temperature sensor: P1K W.K.010 Tolerance Classes: DIN EN F 0.3 (former Class B) Extension : Wire Connections Dimensions (mm): Ordering Information:
17 PRB High Temperature Sensor: ID6 X 15mm probe temp sensor, 100K NTC thermistor Specifications: Nominal Resistance: R25=100kΩ±1% B Value: B25/85=4066K±1% Optimal Operating Temperature Range: -40 ~ +250 C Absolute max 300 Cfor short periods Dimensions (mm): 1: Ø6x15 Stainless Steel 2: UL /2CAWG 250 C Black Wire Absolute max 300 C for short periods Product model specification
18 Ordering Information:
19 Temperature Curves: Part # -> DegC 3K -6 Thermister Type, Ohms / Part Number Suffix 10K Type2-7 10K Type K K -9 1K RTD , , , ,000 4,067, , , , ,600 2,890, , , , ,600 2,077, , , , ,000 1,508, ,092 96,974 78, ,600 1,106, ,868 72,895 63, , , ,589 55,298 47, , , ,694 42,314 38,515 92, , ,795 32,650 29,490 70, ,017 1, ,618 25,395 23,460 53, ,041 1, ,971 19,903 18,790 41, ,807 1, ,714 15,714 15,130 32, ,702 1, ,748 12,493 12,260 25, ,729 1, ,000 10,000 10,000 20, ,000 1, ,416 8,056 8,194 15,884 79,428 1, ,959 6,530 6,752 12,696 63,489 1, ,597 5,324 5,592 10,210 51,058 1, ,310 4,366 4,655 8,258 41,301 1, ,080 3,601 3,893 6,718 33,598 1, ,985 3,327 5,494 27,479 1, ,487 2,760 4,518 22,593 1, ,082 2,375 3,734 18,669 1, ,751 1,990 3,100 15, ,480 1,724 2,586 12,932 1, ,256 1,458 2,186 10, ,070 1,271 1,824 9,121 1, ,084 1,542 7,709 1, ,308 6,542 1, ,114 5, ,767 1, , ,525 1, ,046 1,
20 Wells (Brass and Stainless Steel): Descriptions: The machined stainless steel and brass thermowells are designed for mounting temperature sensors in pipes and tanks. The thermowells are designed to reduce the stress encountered in a flowing fluid installation which produces a constantly oscillating force that can eventually crack a probe unless mounted within one of these wells. The wells are designed to handle the stress, while providing good thermal contact with fluid. They also provide isolation, if the sensor needs to be serviced the system can remain in operation without having to drain the lines. Features & Options: Three Lengths: 2, 4 and 8 Stainless Steel (304) or Brass Two Part (Welded) or Machined Construction Other Lengths or Materials Available Upon Request Limited Lifetime Warranty Ordering Information:
21 Dimensions DDC Type: 2 inch Dimensions (mm): 4 inch & 6 inch Dimensions (mm): 8 inch Dimensions (mm):
22 Honeywell 10mm Capillary Tube:
23 Strap On Temperature Sensor Technical data Measuring range -30 to +180 C -30 to +150 C (NTC) Sensing elements See ordering (other elements on request) Isolation resistance > 100Mohm, at 20 C (500 Vdc) Connections 1-wire (on request 3 and 4-wire) Strap-on band length 300 mm, for pipe diameter 13 to 92 mm (1/4 to 3 ) (other strap-on lengths on request) Cable lenght 1 metres Cable material Silicone Cup dimensions L = 50 mm x D = 6mm Protection IP 54 Features Sensing elements Thermistors, Platinum and Nickel,NTC 10K.,NTC 3K,NTC 10K Type2, NTC 10K Type3,PTC, PT1000, etc Included 300 mm adjustable strap-on band,for pipe diameter 13 to 92 mm (1/4 to 3 ) IP 54 protection Simple 1-wire connection Economical way to measure temperature Application/Description The strap-on temperature sensor is used for sensing the temperature of pipework in heating, ventilation and air conditioning systems. The strap on is passive immersion temperature sensor available with different sensing elements such PT1000, NTC, PTC etc. Passive sensing elements is a low cost alternative to measure temperature with simple 1 wire connection. The sensing element is housed in a 50 mm long probe (cup). The probe will be fixed to the pipe with an adjustable 300 mm,strap-on band, other strap-on lengths on request
24 Strap On Temperature Sensor Application/Description The strap-on temperature sensor is used for sensing the temperature of pipework in heating, ventilation and air conditioning systems.it is passive immersion temperature sensoravailable with different sensing elements such as NTC 10K.,NTC 3K,NTC,10K,Type2,NTC,10K Type3,PTC,PT1000 etc.passive sensing elements is a low cost alt native to measure temperature with simple 1 wire connection. The sensing element is housed in a 50 mm long probe (cup). The probe will be fixed to the pipe with an adjustable 300 mm,strap-on band, other strap-on lengths on request. Ordering Type no. Description NTC 10K Strap-on temperature sensor with cable NTC 3K Strap-on temperature sensor with cable NTC 10K Type2 Strap-on temperature sensor with cable NTC 10K Type3 Strap-on temperature sensor with cable PT1000 Strap-on temperature sensor with cable Dimensions (mm)
25 Ordering Information: *Thermistors,pt elements and probe sizes for all popular control systems are available,send us an if you don t see what you need online
26 Strap On Insert Temperature Sensor: Strap-on Insert Sensor The strap-on Insert sensor consists of a stainless steel sheath temperature sensor, thermal conducting compound, and an adjustable pipe bracket accessory. The stainless steel sheath temperature sensor is suitable for direct application to pipe surfaces for chilled or hot water measurement. It is also used for freezer cases, where moisture protection is important. Strap-on Applications Where it is not practical to install immersion wells, the stainless sheath sensor may be strapped to the pipe. A pipe strap accessory provides a bracket to hold a thermally conductive compound and clamps the sensor securely in place. Make electrical connections to the sensor in accordance with the installation wiring diagram for the job and in accordance with national and local electrical codes. Use the one big-foot lead furnished with the sensor. Do not use wire nuts. Though the sensor itself does not require shielded cable, some controllers and microprocessors do;check with the controller supplier. Accuracy ±36 F from 32 F to 158 F) ±2 C from 0 C to 70 C) Stability 24 F (-4.4 C) over 5 years Basic Model Basic model comes with one foot lead and a 0.24-inch stainless steel tube. Typical Mounting When used as a strap-on Insert sensor, best results are obtained when conductive compound is applied between the sensor and the pipe. In addition, the sensor should be inserted under insulation with at least 4mm of the sensor lead covered. A pipe clamp accessory is available for use with this sensor
27 Strap On Insert Temperature Sensor: Adjustable Pipe Bracket Accessory The pipe bracket is designed for use with the stainless sheath sensor. The bracket can be used on pipe sizes from 2" (50.8mm) to 8" (203mm) outside diameter. Thermal conducting compound should be used with the bracket to improve heat transfer between the pipe and the temperature sensor. Dimensions (mm)
28 Ordering Information: *Thermistors,pt elements and probe sizes for all popular control systems are available,send us an if you don t see what you need online
Pipe Temperature Sensors
Pipe Temperature Sensors Model TE-703 / 704 RoHS Four immersion thermowell installation options brass adapter with 304 SS probe for adjustable insertion, plastic, galvanized steel or NEMA-4/IP-65 steel
A99B Series Temperature Sensors
FANs 125, 121, 930, 930.5 Product/Technical Bulletin A99 Issue Date 0615 A99B Series Temperature s The A99B Series Temperature s are passive PTC (Positive Temperature Coefficient) sensors. The A99B sensors
Duct Temperature Sensors
Duct s Model TE-701 / 702 RoHS More than 16 types of interchangeable NTC thermistors, precision platinum, nickel or balco RTDs are available for universal compatibility. Five installation options probe
Toroidal Conductivity Sensor
Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:
DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
Submersion/Insertion Toroidal Sensor
Instruction Sheet PN 51A-228/rev.P December 2010 Model 228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
FEATURES BODY DIA. MAX. Type M AWG 30: 0.0100 [0.254] Type C AWG 28: 0.0126 [0.320] Type T AWG 30: 0.0100 [0.254]
M, C, T NTC Thermistors, Coated FEATURES Small size - conformally coated. Wide resistance range. Available in 11 different R-T curves. DESCRIPTION Models M, C, and T are conformally coated, leaded thermistors
HMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
T7079A,B Solid State Remote Temperature Controllers
T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature
Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual
0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
BB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
ATL Fuel Level Sender Probes
T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems
APPLICATION AID SAA20 Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems Duct Air page 4 Thermal-Ribbon pages 6-7 Room Air Compact Room Air page
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
NTC Thermistors, Radial Leaded and Coated
M, C, T NTC Thermistors, Radial Leaded and Coated FEATURES Small size - conformally coated Wide resistance range Available in 11 different R-T curves Available in point matched and curve tracking precision
HVAC Sensors Catalogue
HVAC Sensors Catalogue Issue: September 2008 Make the most of your energy TAC the Single Source for all Your HVAC Sensor Needs This catalogue presents the comprehensive HVAC sensor portfolio offered by
Submersion/Insertion Toroidal Sensor
Instruction Manual 228 Sensor LIQ_MAN_ABR_228 May 2014 PN 51A-228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.rosemountanalytical.com CAUTION SENSOR/PROCESS
Mini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
Pressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems
Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems The measurement of temperature is critical in the determination of the true volume of product in a hydrocarbon
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. [email protected] - 800-843-9859 - www.powermation.
14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator
Heating Cable. Construction
Mineral Insulated High Temperature A C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to F (593 C) Maximum Exposure Temperature 4 F (76 C) (Power Off) Corrosion Resistant
Directory chapter 04
M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................
08. SEK IDC CONNECTORS
. IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these
Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS
EPP - 1 DECRIPTION The odel 575 is used in general water/wastewater applications. The transmitter is offered in a standard non-clogging snub nose end, flush diaphragm or protected flush diaphragm with
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new
Typical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
Detection of Pipe Leaks Connection of Pulse Monitoring System in Thermal Utilities
ZPU MIĘDZYRZECZ PREINSULATED PIPE Detection of Pipe Leaks in Thermal Utilities Assembly Manual Principles of Assembly and Servicing ZAKŁAD PRODUKCYJNO USŁUGOWY Międzyrzecz Polskie Rury Preizolowane Sp.
Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.
Thermwire Freeze Protection Heating Cable Selection Guide Pipe Freeze Protection Heating Cable Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord & Plug Thermwire-Comp Refrigeration
EH-20 20m antenna. By VE3RGW
EH-20 20m antenna By VE3RGW Equivalent circuit of EH-20 (prototype 2A) antenna system. Upper cylinder Lower cylinder Ground Counter pose Phasing coil Impedance transformer and tune circuit Tune coil Feed
Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.
Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11
READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!
READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! The main power to any existing system must be disconnected prior to the
V47 Series Temperature Actuated Modulating Water Valves
V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate
RTD Temperature Probe for the Food/Pharmaceutical Industry
[email protected] Data Sheet 902810 Page 1/9 RTD Temperature Probe for the Food/Pharmaceutical Industry For temperatures between -50 and +250 C Protection type up to IP69 according to DIN EN 60529 (IP69K
TC-9102 Series Surface Mount Temperature Controllers
TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may
Scraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
Portable digital microprocessor thermometers with interchangeable probes
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: [email protected] Internet: www.jumo.net
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS
INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS GENERAL DESCRIPTION:
PART 1 - INTRODUCTION...
Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART
Sanitary and CIP Toroidal Sensor
Instruction Sheet PN 51A-225/rev.I December 2010 Model 225 Sanitary and CIP Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS
LM35 Precision Centigrade Temperature Sensors
Precision Centigrade Temperature Sensors General Description Typical Applications The LM35 series are precision integrated-circuit temperature sensors, whose output voltage is linearly proportional to
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
Technical data sheet TDS0070
Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Pressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:
GE Measurement & Control Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low
BLUE RIBBON CORP. BC001 Birdcage Installation Manual
Product Overview: This manual is applicable for the BC001 Birdcage Submersible Level Transmitters. If the product you have has a different prefix part number than listed above please contact the factory
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
Screw Plug Immersion Heaters
Immersion Heaters Overview Immersion Heaters consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. Immersion Heaters
Instruction Manual. T3111 T3111L T3111P T3111Ex
www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs
Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020
Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and vibration resistant
Installation Instructions DTS-HAZ DTS-HAZ-DC. for Use with Self-Regulating & Constant Wattage Heating Cables
Installation Instructions DTS-HAZ DTS-HAZ-DC for Use with Self-Regulating & Constant Wattage Heating Cables PJ944-9 5625-81049 May 2013 1 2 DTS-HAZ Self-Regulating & Constant Wattage Heating Cables Junction
CHM-27 COB Arrays White LED
CHM-27 COB Arrays White LED Features: Table of Contents Technology Overview...2 Test Specifications...2 Chromaticity Bins...3 Product Ordering & Shipping Part Numbers...4 Product Typical Flux Range. 5
Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS
Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and
SMD Rework Station TABLE OF CONTENTS
SMD Rework Station Thank you for purchasing the Hakko 50B SMD Rework Station. The Hakko 50B is designed to solder and desolder surface mounted devices with hot air. Please read this manual before operating
INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)
CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage
Quick Connect. RTDs, Cordsets and Transmitter with M12 Connections
Quick Connect RTDs, Cordsets and Transmitter with M12 Connections 1 Temperature Measurement Experts Since 1960, urns Engineering has been an industry leader in the design and manufacture of temperature
Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System
Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector
3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.
CAST IRON THE BASICS 1. DO NOT LIFT ON YOUR OWN. 2. ONLY LIFT THE RADIATOR VERTICALLY. 3. DO NOT LIFT MORE THAN 8/10 SECTIONS AT ANY ONE TIME. 4. POSITION THE RADIATOR BEFORE FINAL ASSEMBLY. 5. THIS PRODUCT
400 Series - Mini USB Buccaneer
IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,
Capacitive Prox E2K-X
Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows
BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)
CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN
EPHY-MESS GmbH phone: +49 6122 9228-0 Berta-Cramer-Ring 1 fax: +49 6122 9228-99 65205 Wiesbaden email: [email protected] Germany
Temperature sensor PR-SPA-EX-WKF 1. Manufacturer and distributor EPHY-MESS GmbH phone: +49 6122 9228-0 Berta-Cramer-Ring 1 fax: +49 6122 9228-99 65205 Wiesbaden email: [email protected] Germany 2. Applied
B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment
B MOTORPORT COMPONENT B TEMPERATURE ENOR Purpose and unction Temperature sensors used in modern engine management systems are of NTC [negative temperature co-efficient] design. imply as temperature rises
Vario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating
Threaded Resistance Thermometers Model TR10-D, Miniature Design
Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-D, Miniature Design WIKA Data Sheet TE 60.04 Applications Machine building, plant and tank construction Power transmission
Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011
WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers Installation Guide February, 2011 Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 [email protected] 1 Disclaimer The following warranty
RAY-MAX Integrated Solar Power Strip
RAY-MAX Integrated Solar Power Strip 600008, 600009, 600010, 600208, 600209, 600210 Owner s Manual NEXTRONEX, INC. Revision Date: 10/27/14 Contents 1. Safety Instructions... 3 2. General Equipment Warnings...
RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions
Heat-Tracing Remote Monitoring Module for the NGC Control System Installation Instructions Tools Required 3 mm slotted screwdriver 3/8 hex key (for -4X only) Approvals Nonhazardous locations Type NM LISTED
STRATO LED Drivers 70W, Single output
Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED
Munchkin Heat Exchanger Maintenance
Munchkin Heat Exchanger Maintenance By: Mike Granahan *Refer to the appropriate boiler manual for your specific model number. Adjustment procedures will vary. Boiler shown below is an HTP Munchkin 80M
920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown
Self-Regulating 920 Series Dual-point heat-tracing control system Power-Limiting Mineral Insulated 920*E4FWL*SIS302*SS3102 shown Product overview The DigiTrace 920 is a compact, full-featured, microprocessor-based,
INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR
INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR (For NEW 2007 ALL WHITE KWIK-KITS ONLY) Warning do not attempt to install A/C units unless you are experienced with servicing
Thermal Mass Flow Meter (Series MST)
Overview MaxiFlo TM MST series Thermal Mass Flow Meter is the instrument of choice for reliable and accurate measurement of mass flows for various gases. It measures the mass flow of gas based on constant
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8
I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
For Multi-Parameter Meters see mvx
BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up
Explosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
IEC Connectors. Introduction
Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings
ALARMLINE ANALOGUE Linear Heat Detection System
ALARMLINE ANALOGUE Alarmline Analogue sensor cable senses temperature variations by continuously monitoring the resistance of specially doped N.T.C. polymeric insulation. A change in temperature produces
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184
EN KNX TH65-AP Thermo-Hygrometer Technical specifications and installation instructions Item number 70184 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49
Stainless steel process fittings
Page 1/6 Stainless steel process fittings Installation in pipe systems Installation in tanks and vessels Hygienic version FDA conformity of materials Probe length 120 mm 120 mm Availability of various
Thermistor Basics. Application Note AN-TC11 Rev. A. May, 2013 Page 1 WHAT IS A THERMISTOR?
Thermistor Basics May, 2013 Page 1 WHAT IS A THERMISTOR? A thermistor is a resistance thermometer, or a resistor whose resistance is dependent on erature. The term is a combination of thermal and resistor.