RTI-1. IECEx. Ready-to-Install TRY, TRX, THZ 3 & STZ Temperature Transmitter Assemblies
|
|
|
- Peregrine Marsh
- 9 years ago
- Views:
Transcription
1 November 2015 Your One Stop Temp Shop for Complete Temperature Assemblies Why waste valuable time searching around for temperature assembly pieces and parts? Our readyto-install temperature transmitter assemblies feature: Universal TRY & TRX PC-Programmable, THZ 3 Smart HART and STZ Functional Safety Temperature Transmitters. General location, hazardous area, and explosion-proof/fl ameproof connection heads. STZ was designed and built according to IEC requirements and is exida approved SIL 3 capable for use in Safety Instrumented Systems. Wide variety of RTD and thermocouple sensors. Spring-loaded fi ttings allow you to easily separate the sensor and transmitter from the thermowell. Industrial-strength stainless steel thermowells, fl anges, and fi ttings in the sizes and confi gurations you need most. Remarkable accuracy of up to ±0.014 C (±0.025 F) using a THZ 3 or STZ and our Calibration Suite. Complete NIST-traceable calibration records available from our state-of-the-art Calibration Suite. One Ordering Number Specify your complete temperature transmitter assembly using one simple table and ordering number. Certifications IECEx Approvals for Hazardous 'Classifi ed' Areas including Explosion-Proof/Flameproof, Intrinsically-Safe, Non-Incendive Type "n" and Functional Safety IEC are available. Consult the individual temperature transmitter data sheets for specifi c information for each certifying agency. NOTE: Certifi cations apply to the temperature transmitter and connection head combination. Sensor and sensor assembly components are not included in FM, CSA and IECEx certifi cations. Complete temperature transmitter assemblies including sensors are available with ATEX and ANZEx certifi cations. Selection Guide with Sensors and s Types and Fitting Selection Temperature Transmitter Specifi cations Sensor Specifi cations Pages 2-3 Pages 4-6 Page 7 Page Moore Industries-International, Inc E All product names are trademarks of their respective companies. HART is a registered trademark of FieldComm Group. Page 1
2 Standard Temperature Assemblies with Sensor and 88mm (3.45 in) Connection Head (Standard LH connection head- LH2NS shown. For additional dimensions see Page 6) Universal Temperature Transmitter LH Connection Head 93mm (3.66 in) Fitting ( N Dimension) (Standard NUE Nipple-Union-Spring Loaded Fitting shown. For Dimensions of ECS Spring Loaded and FLS Fluid Seal Fittings, see Page 6) Standard Nipple, Union, Spring-Loaded Fitting ( N Dimension) 140mm (5.51 in) Assembled (Threads Engaged) Lagging Extension ( T Dimension) (Standard No Lagging, 0-inches shown) Process Connection (Threaded, 1/2-inch NPT connection shown) Standard Wrench and Thread with No Lagging Extension 44mm (1.75 in) (Standard SS316 Heavy-Duty Tapered shown; see Page 4 for additional dimensions of tapered, straight, and stepped thermowells) Sensor (RTD or thermocouple) Insertion Length ( U Dimension) (, specify in 0.25-inch Page 2
3 Standard Temperature Assemblies with Fixed Immersion Sensor 88mm (3.45 in) Connection Head (Standard LH connection head- LH2NS shown. For additional dimensions see Page 6) Universal Temperature Transmitter LH Connection Head 93mm (3.66 in) Process Connection 1/2-inch NPT Standard Wrench and Thread 41mm (1.63 in) Assembled (Threads Engaged) Sensor Length ( CL Dimension) (, specify in 0.25-inch Sheath OD Standard: D25 = 0.25 in DIA. Optional: D38 = in DIA. D18 = in DIA. Page 3
4 Selection Figure 1. Heavy-Duty Threaded, Tapered s (Standard) are convenient to install and replace. Being heavy-duty, they will withstand a high force and high velocity factor from process fl uid fl ow. They are easy to weld or braze for applications which require sealing. 1/2-inch NPT Wrench 0.75 in Figure 2. Standard-Duty Threaded, Stepped s (Standard), convenient to install and replace, deliver a faster response time than tapered or straight wells, but less strength and capability to withstand high force and high velocity from the process fl uid fl ow. They are easy to weld or braze for applications which require sealing. 1/2-inch NPT Wrench 0.75 in Process Connection P2 = 1/2-inch NPT P3 = 3/4-inch NPT P1 = 1-inch NPT 0.25 in 0.26 in Bore Lagging Extension T Thread 1.0 in Process Connection P2 = 1/2-inch NPT P3 = 3/4-inch NPT P1 = 1-inch NPT 2.50 in 0.26 in Bore Lagging Extension T Thread 1.0 in 0.63 in DIA. Figure 3. Standard-Duty Threaded, Straight s (Standard), convenient to install and replace, will withstand a high force and high velocity factor from the process fl uid fl ow, but less than that of the heavy duty well because of lower natural frequency. They are easy to weld or braze for applications which require sealing in DIA. Figure 4. Flanged s provide easy removal and high pressure resistance (shown with a Straight ). Tapered and Stepped can also be ordered as Flanged Wells. See Table 1 for available process connection fl ange sizes. 1/2-inch NPT Wrench 0.75 in 1.25 in DIA. 1/2-inch NPT Lagging Extension T Lagging Extension T Process Connection P2 = 1/2-inch NPT P3 = 3/4-inch NPT P1 = 1-inch NPT Thread 1.0 in 0.26 in Bore Flange Size & Facing (As Required) 0.25 in WELD 0.26 in Bore 0.75 in, 0.63 in OR 0.88 in DIA. (depending on process connection) 0.75 in DIA. Socket Wells and Van Stone Wells are also available. Contact the factory for more information. Page 4
5 Figure 5. PTB-P2, P1, P3 Heavy Duty Protection Tube - for heavy wall construction applications. Figure 6. PTB-P2C, P1C, P3C WORM Sensor Protection Tube - for use in light duty applications with standing liquid or slow-moving gas. Fixed Length 3.0 in 1/2-14-inch NPT Wrench 0.75 in 0.87 in Retaining Screw 8-24 UNF Brass P2C = 1/2-14-inch NPT P3C = 3/4-14-inch NPT P1C = 1-inch NPT Process Connection P3 = 3/4-14-inch NPT P2 = 1/2-14-inch NPT P1 = inch NPT Thread 1.0 in OD 0.38 in DIA. OD 0.50 in DIA in DIA. Thick Wall 0.26 in DIA. Figure 7. SW1, SW2 and SW3 Heavy Duty Tapered Stem - for weld in socket-welding fi tting. Figure 8. Sanitary Wells - Cap sizes D75 through D4; SS316 low carbon material with a high polish. Thermo-Lagging Length Socket Length 1.75 in Socket OD 1.05 in DIA. = SW in DIA. = SW in DIA. = SW in in DIA. 1/2-14-inch NPT Cap OD D.5 for in O.D. Well D.75 for in O.D. Well D1 for in O.D. Well D1.5 for in O.D. Well D2 for in O.D. Well D2.5 for in O.D. Well D3 for in O.D. Well 0.26 in Bore 0.25 in Insertion Length U 0.26 in Bore 0.25 in 0.63 in DIA. OD 0.75 in DIA in DIA in DIA. OD 0.50 in DIA. Page 5
6 Figure 9. Dimensions for LH2 Explosion-proof/Flameproof Connection Head. 72mm DIA. (2.85 in) 93mm (3.68 in) Fitting Selection Figure 10. NUE, NUN and NUR Nipple, Union, Spring-Loaded Fitting (Standard) - Combination fi tting is used with the WORM sensor. It uses a union to allow easy assembly of the entire system. It can be adjusted as many times as required. 140mm Assembled (Threads Engaged) (5.50 in) Table 1. Process Connection Flange Sizes. Ordering Code F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 F15 F16 F17 F18 F19 F20 F21 F22 F23 F24 F25 F26 F27 F28 F29 F30 F31 F32 F33 F34 F35 F36 Flange Size 1-inch, 150#, Flat Facing 1-inch, 150#, Raised Facing 1-inch, 150#, Ring Type Joint 1 1/2-inch, 150#, Flat Facing 1 1/2-inch, 150#, Raised Facing 1 1/2-inch, 150#, Ring Type Joint 2-inch, 150#, Flat Facing 2-inch, 150#, Raised Facing 2-inch, 150#, Ring Type Joint 1-inch, 300#, Flat Facing 1-inch, 300#, Raised Facing 1-inch, 300#, Ring Type Joint 1 1/2-inch, 300#, Flat Facing 1 1/2-inch, 300#, Raised Facing 1 1/2-inch, 300#, Ring Type Joint 2-inch, 300#, Flat Facing 2-inch, 300#, Raised Facing 2-inch, 300#, Ring Type Joint 1-inch, #, Flat Facing 1-inch, #, Raised Facing 1-inch, #, Ring Type Joint 1 1/2-inch, #, Flat Facing 1 1/2-inch, #, Raised Facing 1 1/2-inch, #, Ring Type Joint 2-inch, #, Flat Facing 2-inch, #, Raised Facing 2-inch, #, Ring Type Joint 1-inch, #, Flat Facing 1-inch, #, Raised Facing 1-inch, #, Ring Type Joint 1 1/2-inch, #, Flat Facing 1 1/2-inch, #, Raised Facing 1 1/2-inch, #, Ring Type Joint 2-inch, #, Flat Facing 2-inch, #, Raised Facing 2-inch, #, Ring Type Joint 30mm (1.20 in) Figure 11. FLS Fluid Seal Fitting and OS Spring-Loaded Oil Seal are used for transmitter assemblies with thermowells and assemblies with fi xed immersion sensors (it is not used with WORM sensors). It prevents fl uid leak along the sensor sheath so it s ideal for using temperature sensitive paste or heat transfer fl uid in the thermowell. It can also be used in air ducts and other applications. Although the FLS provides adjustment precision, it crimps the sensor sheath, and can therefore be adjusted only once (up to 0.50 in). ECS 38mm Assembled (Threads Engaged) (1.50 in) Figure 12. ECS and RES Spring-Loaded Fittings and NPL Nipple assure a good thermal connection between the sensor and thermowell offering a quick response time. This fi tting is not used with the WORM sensors. For the WORM, use the NPL fi tting. 51mm Assembled (Threads Engaged) (2.00 in) NPL RES Page 6
7 Temperature Transmitter Specifications TRY & TRX PC-Programmable Temperature Transmitters In one minute from one software window, you can confi gure our TRY (isolated) and TRX (non-isolated) 2-wire (loop-powered) transmitters to handle nearly every temperature application in your plant. The Intelligent PC Confi guration Software that you need for set up is supplied FREE with your order. Programmable parameters include: Input type and range; output range; output damping; sensor trim offset; RJC or no RJC; linearization or no linearization; temperature readout in C or F; and upscale or downscale drive on sensor burnout Basic TRY & TRX Specifications: Temperature Assemblies Come with Transmitter Model Number: TRY / PRG / 4-20MA / 10-42DC / [HOUSING CHOICE] TRX / PRG / 4-20MA / 8-42DC / [HOUSING CHOICE] Input: See Table 2 Output: 4-20mA output is accurate to within ±0.03% of input span Power: TRY: 10-42Vdc (loop-powered) TRX: 8-42Vdc (loop-powered on output side) RJC Accuracy (T/C inputs only): ±0.45 C Linearity: 0.1% of span, within rated ranges Isolation (TRY Only): 1500Vrms input to output to case RFI/EMI Protection: Operating and Storage Range: 40 C to +85 C ( 40 F to +185 F) Ambient Temperature Effect on Accuracy: ±0.015% of span/ C change, maximum (+0.001% of ohm reading for RTD inputs Ambient Temperature Effect on RJC (T/C only): ±0.015 C/ C change For detailed specifications, see the TRY/TRX Data Sheet Sensor Specifications Lead Wires: Standard WORM (WS) Sensors: Tefl on insulated, hermetically sealed for measurements up to 232 C (450 F) High Temperature WORM (WH) Sensors: Braided fi berglass for measurements ranging from 232 C (450 F) up to 427 C (800 F). Inconel (INC) sheathed WORM sensors: Special fi berglass insulation withstands temperatures up to 1,093 C (2,000 F) Wire Size: Wire gauges range from 20 to 28 depending on the element type. Accuracy: RTD: ±0.12% at 0 C. Consult the factory for thermocouple tolerances. Stability: RTD: 0.2 C after 10,000 hours at maximum temperature (1 year, 51 days, 16 hours continuous) Response Time (typical to reach a 63.2% temperature change): RTD: <5 seconds; Grounded Thermocouples 2.0 sec.; ungrounded Thermocouples 4.5 sec. Vibration Options: 10G: Provides protection for sensors that are exposed to higher than normal vibration levels. 30G: Sensor is encapsulated in a waterproof epoxy to endure extreme vibration levels and full water immersion. Spring: 302 Stainless Steel. Withstands continuous temperatures up to 1093 C (2000 F). THZ 3 Smart HART Temperature Transmitter HART confi gurable via any HART handheld confi gurator or HART compatible host. Additionally program or monitor with any FDT compliant host or program, such as PACTware, utilizing our DTM. STZ Functional Safety Dual Input Smart HART Temperature Transmitter Designed and built from the ground up in accordance with IEC requirements. It is exida approved and certifi ed SIL 3 capable for use in a Safety Instrumented System. Programmable parameters include: Input type and range; output range; output damping; sensor trim offset; temperature readout in C or F; and upscale or downscale drive on sensor burnout. Basic THZ 3 and STZ Specifications: Temperature Assemblies Come with Transmitter Model Number: THZ 3 / TPRG / 4-20MA / 12-42DC / [HOUSING CHOICE] STZ / PRG / 4-20MA / 12-42DC / [HOUSING CHOICE] Input: See Table 2 Output: 4-20mA output is accurate to within ±0.015% of input span Power: 12-42Vdc (loop-powered) RJC Accuracy (T/C inputs only): ±0.25 C Isolation: 500Vrms input to output continuous RFI/EMI Protection: Operating and Storage Range: 40 C to +85 C ( 40 F to +185 F) For detailed specifications, see the THZ 3 and STZ Data Sheets Table 2. TRY, TRX, THZ 3 and STZ Input Specifi cations Input Type Range Accuracy TRY & TRX PC-Programmable Temperature Transmitters PT14 Platinum RTD; 3- and 4-Wire; 100 ohm, α = (standard) PT104 Platinum RTD; 3- and 4-Wire; 1000 ohm, α = (standard) CU4 Copper RTD; 3- and 4-Wire; 10 ohm, α = N1204 Nickel RTD; 3- and 4-Wire; 120 ohm, α = TCJ J-Type T/C TCK K-Type T/C PT14 Platinum RTD; 3- and 4-Wire; 100 ohm, α = (standard) PT104 Platinum RTD; 3- and 4-Wire; 1000 ohm, α = (standard) N1204 Nickel RTD; 3- and 4-Wire; 120 ohm, α = CU4 Copper RTD; 3- and 4-Wire; 10 ohm, α = TCJ J-Type T/C TCK K-Type T/C 200 to +850 C ( 328 to F) 200 to +850 C ( 328 to F) 50 to +250 C ( 58 to +482 F) 80 to +320 C ( 112 to +608 F) 180 to +770 C ( 292 to F) 150 to C ( 238 to F) THZ 3 Smart HART & STZ Functional Safety Dual Input Temperature Transmitters 200 to +850 C ( 328 to F) 200 to +850 C ( 328 to F) 80 to +320 C ( 112 to +608 F) 50 to +250 C ( 58 to +482 F) 180 to +760 C ( 292 to F) 150 to C ( 238 to F) ±0.21 C ±0.38 F ±0.21 C ±0.38 F ±1.2 C ±2.16 F ±0.16 C ±0.29 F ±0.28 C ±0.5 F ±0.3 C ±0.54 F ±0.1 C ±0.18 F ±0.1 C ±0.18 F ±0.1 C ±0.18 F ±0.85 C ±1.53 F ±0.25 C ±0.45 F ±0.3 C ±0.54 F Page 7
8 Select one from each category to order a Temperature Assembly with the WORM Sensor and : Universal Temperature Transmitter (See Page 7, and the TRY/TRX, THZ 3 and STZ Data Sheets for Specifi cations) THZ 3 Isolated, Dual Input Smart HART Temperature Transmitter (Standard) STZ Isolated, Functional Safety Dual Input Smart HART Temperature Transmitter (Standard) TRX Non-Isolated, PC-Programmable Temperature Transmitter (Standard) TRY Isolated, PC-Programmable Temperature Transmitter (Standard) WEL 6-Position Terminal Block: No Transmitter (Standard) Type (See Pages 4 and 5 for Descriptions and Dimensions) A Heavy-Duty Threaded, Tapered Well B Standard-Duty Threaded, Straight Well C Standard-Duty Threaded, Stepped Well PTB Protection Well and Tube (Available in SS316) -Heavy Duty Protection Tube - Select (-P2, -P3, -P1) Process Threads -Light Duty Protection Well - Select (-P2C, -P3C, -P1C) No Process Thread Process Connection Size (See Page 6) P2 Threaded, ½-inch NPT (A, B, C Well) P3 Threaded, ¾-inch NPT (A, B, C Well) P1 Threaded, 1-inch NPT (Well) F? Flanged Well, Replace "?" with Ordering Code from Table 1 on Page 6 SW? Welded, Replace "?" with Size: SW1 = 1-inch, SW2 = ½-inch, SW3 = ¾-inch, SW4 = 1¼-inch S-D? Sanitary Well, Replace "?" with Cap Diameter, (D.5 = inch, D.75 = inch, D1 = inch, D1.5 = inch, D2 = inch, D2.5 = inch, D3 = inch) P2C Threaded, 0.5-inch NPT with Straight Stem = inch O.D. Protection Tube (Cold Side Only and Light Duty, No Process Threads) P3C Threaded, 0.75-inch NPT with Straight Stem = inch O.D. Protection Tube (Cold Side Only and Light Duty, No Process Threads) P1C Threaded, 1-inch NPT with Straight Stem = inch O.D. Protection Tube (Cold Side Only and Light Duty, No Process Threads) Insertion Length ( U Dimension) (See Pages 4 and 5) U? Replace "?" with any Insertion Length in 0.25-inch Increments (, specify in 0.25-inch Lagging Extension Length ( T Dimension) (See Pages 4 and 5) T0 No Lagging, 0-inches (Standard) T? Replace "?" with Length in 0.25-inch Increments Material S304 SS304 (Standard) S316 SS316 (Standard; PTB in S316) CS Carbon Steel BR Brass S310 Stainless Steel 310 for Temperatures of 1093 C (2000 F) S446 Stainless Steel 446 for Temperatures of 1093 C (2000 F) INC Inconel 600 (Other Materials Available - Consult Factory) Fitting Type ( N Dimension) (See Page 6 for Descriptions and Dimensions) Don t See What You Need? This bulletin features just a sample of the wide range of temperature assembly choices we offer. Whatever your temperature assembly needs are, our interface solution experts are ready to help! 26 - NUN Nipple-Union, Nipple 26 - NPL 1/2-inch Nipple, 2.5-inches long 26 - NPL3 1/2-inch Nipple, 3-inches long Continued on next page TRY C P2 U4 T0 S NUN WSPT [LH1NS] (Ordering Number Example) Page 8
9 Select one from each category to order a Temperature Assembly with the WORM Sensor and : Sensor Type (See Page 7 for Specifi cations) - WSPT14 Standard Temperature, Pt 385 RTD; 4-Wire; 100 ohm (450 F maximum) - WS2PT14 Standard Temperature Pt 385 RTD; 4-Wire; 100 ohm (Dual Sensor, 450 F maximum) - WSPT104 Standard Temperature, Pt 385 RTD; 4-Wire; 1000 ohm (450 F maximum) - WHPT14 High Temperature, Pt 385 RTD; 4-Wire; 100 ohm (800 F maximum) - WH2PT13 High Temperature Pt 385 RTD; 3-Wire; 100 ohm (Dual Sensor, 800 F maximum) - WHPT104 High Temperature WORM, Pt 385 RTD; 4-Wire; 1000 ohm, 800 F maximum) - WSN1204 Nickel RTD; 4-Wire; 120 ohm (450 F maximum) - WSCU4 Copper RTD; 4-Wire; 10 ohm (450 F maximum) - WSTC?G Standard Temperature, Replace "?" with J, K, T or E T/C, Grounded (450 F maximum) - WS2TC?G Standard Temperature, Replace "?" with J, K, T or E T/C, Grounded (Dual Sensor, 450 F maximum) - WSTC?U Standard Temperature, Replace "?" with J, K, T or E T/C, Ungrounded (450 F maximum) - WS2TC?U Standard Temperature, Replace "?" with J, K, T or E T/C, Ungrounded (Dual Sensor, 450 F maximum) - WHTC?G High Temperature, Replace "?" with J, K, T or E T/C, Grounded - WH2TC?G High Temperature, Replace "?" with J, K, T or E T/C, Grounded (Dual Sensor) - WHTC?U High Temperature, Replace "?" with J, K, T or E T/C, Ungrounded - WH2TC?U High Temperature, Replace "?" with J, K, T or E T/C, Ungrounded (Dual Sensor) *Note: Other RTD and T/C types are also available. Consult factory for details. RTD Sensors Thermocouple Sensors Options (See Page 7 for Descriptions) /3 DIN High Accuracy RTD Sensor (.04%) -.06 Class "A" High Accuracy RTD Sensor (.06%) -10G 10G Low-Intensity Vibration Sensor -30G 30G High-Intensity Vibration Sensor -VTB High Accuracy Temperature System Calibration with NIST Test Data Report (Add.04% or.06% Accuracy RTD) -VTD Standard Factory Calibration with NIST Test Data Report -SSB?-BOOT Replace "?" with SS Braid Length (in 1-inch Increments), 12-inch minimum (Specify Only with RM? If Required) -FLEX?-BOOT Replace "?" with Flexible Armored Cable Length (in 12-inch Increments)* (Specify Only with RM? If Required) -.5NPT-FLEX? 1/2-inch Fitting Attached to FLEX Armor Cable and Threads into Well, Replace "?" With FLEX Armor Length in Inches. -GRIP 1/2-inch NPT Cord Grip to Hold Sensor Lead Wires into Enclosure -LL? Special Wire Jacket Length Plus 6-8" Lead Wires, Replace "?" with Lead Wire Length (in 0.25-In. Increments)* -WW Wire Wound Option for Temperatures Below -10 F (For RTDs Only) -ETR Extended Temperature Required Above +800 F to 1000 F (RTDs only) -RM?** Remote-Mounted (-TB6); Replace "?" with Connection Head Type for the Terminal Block, i.e. -RMLH1NS -TB6 6-Position Terminal Block (Specify When No Transmitter is Selected) -TB8 -FS 8-Position Terminal Block (Mounted in Enclosure, Specify When No Transmitter) Functional Safety (Yellow) LH2 Housing. Can Only be Ordered with LH2* Connection Head or with STZ and RMLH2* Option Connection Head (See Pages 2, 3 and 6 for Dimensions) LH1NS** Aluminum Body with Valox (357U) Cap, NEMA 4X, IP66 (Not available with STZ) LH2NS** Aluminum Body with Aluminum Cap, Explosion-Proof/Flameproof CH6 Polypropylene Body and Cap, NEMA 4 CH3 Polypropylene Body and Cap, NEMA 4 with Integral Terminal Block CH21 Stainless Steel 316 Body and Cap, NEMA 4; used with Transmitter CH19 Stainless Steel 316 Body and Cap, NEMA 4; used with TB6, Terminal Block CH0 No Connection Head (Well with Sensor Assembly Only) WEL Well Only (No Sensor, Transmitter, Fitting or Connection Head) **Note: Add "P" Suffi x to Enclosure (i.e., LH1NSP) for 2-inch Pipe-Mount Hardware. See Previous Page for detailed information IMPORTANT NOTE Specify Standard Temperature WS* WORM sensors for measurements up to 232 C (450 F) Specify High Temperature WHPT* WORM sensors for measurements up to 427 C (800 F). Specify High Temperature WHTC* WORM Sensors for measurements up to 760 C (1400 F). For temperatures up to 1093 C (2000 F), specify WHTCKG or WHTCKU with a CL2 Sheath Length and Inconel Material. TRY C P2 U4 T0 S NUN WSPT [LH1NS] (Ordering Number Example) Page 9
10 Select one from each category to order a Temperature Assembly with Straight Sensor And : Universal Temperature Transmitter (See Page 7, and the TRY/TRX, THZ 3 and STZ Data Sheets for Specifi cations) THZ 3 STZ TRX TRY WEL Page 10 Isolated, Dual Input Smart HART Temperature Transmitter (Standard) Isolated, Functional Safety Dual Input Smart HART Temperature Transmitter (Standard) Non-Isolated, PC-Programmable Temperature Transmitter (Standard) Isolated, PC-Programmable Temperature Transmitter (Standard) 6-Position Terminal Block: No Transmitter (Standard) Type (See Pages 4 and 5 for Descriptions and Dimensions) A B C Heavy-Duty Threaded, Tapered Well Standard-Duty Threaded, Straight Well Standard-Duty Threaded, Stepped Well Process Connection Size (See Page 6) P2 Threaded, ½-inch NPT P3 Threaded, ¾-inch NPT P1 Threaded, 1-inch NPT F? Flanged Well, Replace "?" with Ordering Code from Table 1 on Page 6 SW? Welded, Replace "?" with size: SW1 = 1-inch, SW2 = ½-inch, SW3 = ¾-inch, SW4 = 1¼-inch S-D? Sanitary Well, Replace "?" with Cap Diameter, (D.5 = inch, D.75 = inch, D1 = inch, D1.5 = inch, D2 = inch, D2.5 = inch, D3 = inch) Don t See What You Need? This bulletin features just a sample of the wide range of temperature assembly choices we offer. Whatever your temperature assembly needs are, our temperature interface solution experts are ready to help! Insertion Length ( U Dimension) (See Pages 4 and 5) U? Replace "?" with any Insertion Length in 0.25-inch Increments (, specify in 0.25-inch Lagging Extension Length ( T Dimension) (See Pages 4 and 5) T0 No Lagging, 0-inches (Standard) T? Replace "?" with Length in 0.25-inch Increments Material S304 SS304 (Standard) S316 SS316 (Standard) CS Carbon Steel BR Brass S310 Stainless Steel 310 for Temperatures of 1093 C (2000 F) S446 Stainless Steel 446 for Temperatures of 1093 C (2000 F) INC Inconel 600 (Other Materials Available - Consult Factory) Fitting Type ( N Dimension) (See Page 9 for Descriptions and Dimensions) 26 NUE Nipple-Union Spring-Loaded Fitting (Standard) 26 NUR Nipple, Union, Removable Spring-Loaded Fitting (Specify VTB option) 26 ECS Spring Loaded Fitting 26 RES Spring Loaded Fitting (Specify when ordering VTB option) 26 FLS Fluid Seal Fitting 26 OS Spring-Loaded Oil Seal Sensor Type (See Page 7 for Specifi cations) - PT14 Platinum 385 RTD; 3- and 4-Wire; 100 ohm - PT104 Platinum 385 RTD; 3- and 4-Wire; 1000 ohm - CU4 Copper RTD; 3- and 4-Wire; 10 ohm - N1204 Nickel RTD; 3- and 4-Wire; 120 ohm - 2PT14 Dual Element Pt 385 RTD; 3- and 4-Wire; 100 ohm - 2PT104 Dual Element Pt 385 RTD; 3- and 4-Wire; 1000 ohm - TCJG J-Type Thermocouple; Grounded - TCJU J-Type Thermocouple; Ungrounded - TCKG K-Type Thermocouple; Grounded - TCKU K-Type Thermocouple; Ungrounded - TC?G Replace "?" with other T/C type E, T, R, S, N, B or C; Grounded - TC?U Replace "?" with other T/C type E, T, R, S, N, B or C; Ungrounded - 2TC?G Replace "?" with J, K, T or E T/C, Grounded (Dual Sensor) - 2TC?U Replace "?" with J, K, T or E T/C, Ungrounded (Dual Sensor) *Note: Other RTD and T/C types are also available. Consult factory for details. Continued on next page TRY C P2 U4 T0 S NUR PT [LH1NS] (Ordering Number Example)
11 Select one from each category to order a Temperature Assembly with Straight Sensor And : Options (See Page 7 for Descriptions) /3 DIN High Accuracy RTD Sensor (.04%) -.06 Class "A" High Accuracy RTD Sensor (.06%) -VTB High Accuracy Temperature System Calibration with NIST Test Data Report (Add.04 or.06 Accuracy RTD) -VTD Standard Factory Calibration with NIST Test Data Report -WW Wire Wound Option for Temperatures Below -10 F (For RTDs Only) -ETR Extended Temperature Required Above +800 F to 1000 F (RTDs Only) -RM? Remote-Mounted Terminal Block; Replace "?" with Connection Head Type for the Terminal Block, i.e. -RMLH1NS -TB6 6-Position Terminal Block (Specify when No Transmitter is Selected) -TB8 8-Position Terminal Block (Mounted in Enclosure, Specify When No Transmitter) -FS Functional Safety (Yellow) LH2 Housing. Can Only be Ordered with LH2* Connection Head or with STZ and RMLH2* Option Connection Head LH1NS** Aluminum Body with Valox (357U) Cap, NEMA 4X, IP66 (Not available with STZ) LH2NS** Aluminum Body with Aluminum Cap, Explosion-Proof/Flameproof CH6 Polypropylene Body and Cap, NEMA 4 CH3 Polypropylene Body and Cap, NEMA 4 with Integral Terminal Block CH21 Stainless Steel 316 Body and Cap, NEMA 4; used with Transmitter CH19 Stainless Steel 316 Body and Cap, NEMA 4; used with TB6, Terminal Block CH0 No Connection Head (Well with Sensor Assembly Only) WEL Well Only (No Sensor, Transmitter, Fitting or Connection Head) **Note: Add "P" Suffi x to Enclosure (i.e., LH1NSP) for 2-inch Pipe-Mount Hardware. See Previous Page for detailed information TRY C P2 U4 T0 S NUR PT [LH1NS] (Ordering Number Example) Factory Calibration Available Sensor-to-Transmitter Trimming Our state-ofthe-art Calibration Suite provides exceptional accuracy by immersing the system's sensor in a precision calibration bath, then using the transmitter to "capture" the sensor's true readings. This method effectively compensates for errors caused by inherent sensor inaccuracies. The system is delivered configured, calibrated, and ready for installation. NIST traceable test data is supplied with each system. To order, specify option VTB in the model number. NIST Traceable Test Report Moore Industries will confi gure the temperature transmitter and calibrate zero and span points with customer-supplied values using a precision simulated sensor input. NIST traceable test data indicating actual recorded values is supplied with each instrument. To order, specify option VTD in the model number. Remote-Mounted Terminal Block Remove the Display From the Process Position your sensor in the heart of your process while keeping your transmitter in an easily accessible area with our Remote Terminal Block option. Add the RM? option to your temperature assembly and receive two housings: a transmitter in the specifi ed connection head, and a terminal block enclosed in an additional connection head with your selected sensor and fi ttings attached. Sensor extension wiring (not included) connects the terminal block to the transmitter. (Sensor Extension Wiring Not Included) 4-20mA To Control/Monitoring System Page 11
12 Select one from each category to order a Temperature Assembly with Fixed Immersion Sensor: Universal Temperature Transmitter (See Page 7 and TRY/TRX, THZ 3 and STZ Data Sheets for Specifi cations) THZ 3 Isolated, Dual Input Smart HART Temperature Transmitter (Standard) STZ Isolated, Functional Safety Dual Input Smart HART Temperature Transmitter (Standard) TRX Non-Isolated, PC-Programmable Temperature Transmitter (Standard) TRY Isolated, PC-Programmable Temperature Transmitter (Standard) SEN Sensor Only; No Transmitter (Standard) Sensor Length ( CL Dimension) (See Page 3) CL? Replace "?" with any Sensor Length (e.g., CL2.75, CL6) (2- through 16-inch Lengths are Standard) Sensor Sheath Diameter D12 D18 D25 D inch Diameter (Consult Factory) inch Diameter (Consult Factory) 0.25-inch Diameter (Standard) 0.38-inch Diameter (Consult Factory) Sensor Sheath Material S316 SS316 (Standard) INC Inconel 600 Don t See What You Need? This bulletin features just a sample of the wide range of temperature assembly choices we offer. Whatever your temperature assembly needs are, our temperature interface solution experts are ready to help! Sensor Type (See Page 6 for Specifi cations) PT1C4 Platinum 385 RTD; 3- and 4-Wire; 100 ohm PT10C4 Platinum 385 RTD; 3- and 4-Wire; 1000 ohm 2PT14 Dual Element Pt 385 RTD; 3- and 4-Wire; 100 ohm 2PT104 Dual Element Pt 385 RTD; 3- and 4-Wire; 1000 ohm CUC4 Copper RTD; 3- and 4-Wire; 10 ohm NC1204 Nickel RTD; 3- and 4-Wire; 120 ohm TCC?G Replace "?" with J, K, T, E, R, S, N, B or C T/C, Grounded TCC?U Replace "?" with J, K, T, E, R, S, N, B or C T/C, Ungrounded 2TC?G Replace "?" with J, K, T or E T/C, Grounded (Dual Sensor) 2TC?U Replace "?" with J, K, T or E T/C, Ungrounded (Dual Sensor) Options (See Page 6 for Descriptions) Sensor Options: /3 DIN High Accuracy RTD Sensor (.04%) -.06 Class "A" High Accuracy RTD Sensor (.06%) -VTB High Accuracy Temperature Bath Calibration with NIST Test Data -VTD Standard Factory Transmitter Calibration with NIST Test Data -WW Wire Wound Option for Temperatures Below -10 F (For RTDs Only) -ETR Extended Temperature Required above +800 F to 1000 F (RTDs only) -TB6 6-Position Terminal Block (Mounted in Enclosure) -TB8 8-Position Terminal Block (Mounted in Enclosure, Specify When No Transmitter) Enclosure Options: -RM?** Remote-Mounted Terminal Block; Replace "?" with Connection Head Type for the Terminal Block, i.e. -RMLH1NS (Include -LL? Needed) -LL? Special Wire Jacket Length plus 6-8" Lead Wires - Replace "?" with Length up to 120" (Specify in 0.25-inch Increments) -FS Functional Safety (Yellow) LH2 Housing. Can Only be Ordered with LH2* Connection Head or with STZ and RMLH2* Option THZ3 CL6 D25 S316 -PT10C4.06 [LH2NS] (Ordering Number Example) Connection Head LH1NS** Aluminum Body with Valox Cap, NEMA 4X, IP66 (Not available with STZ) LH2NS** Aluminum Body with Aluminum Cap, Explosion-Proof/Flameproof CH6 Polypropylene Body and Cap, NEMA 4X CH3 Polypropylene Body and Cap, NEMA 4X with Integral Terminal Block CH21 Stainless Steel 316 Body and Cap, NEMA 4X CH19 Stainless Steel 316 Body and Cap, NEMA 4X SEN Sensor Only (No Transmitter or Head) ** Add "P" Suffi x to Enclosure (i.e., LH1NSP) for 2-inch Pipe-Mount Hardware. Page 12 Specifi cations are subject to change without notice. Printed in the USA.
Rosemount DIN-Style Temperature Sensors and Thermowells (Metric)
Product Data Sheet July 2015 00813-0200-2654, Rev KA Rosemount DIN-Style Temperature Sensors and Thermowells (Metric) RTDs (0065) and thermocouples (0185) available to meet any process requirement DIN-style
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems
Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems The measurement of temperature is critical in the determination of the true volume of product in a hydrocarbon
RTD Temperature Probe for the Food/Pharmaceutical Industry
[email protected] Data Sheet 902810 Page 1/9 RTD Temperature Probe for the Food/Pharmaceutical Industry For temperatures between -50 and +250 C Protection type up to IP69 according to DIN EN 60529 (IP69K
BULLET. Description. Features. WirelessHART Adapter for Use with Wired HART Field Devices
March 0 Description The enables new and existing wired smart HART fi eld devices, non-smart analog fi eld devices and remote HART I/O from any supplier to communicate with host applications using technology.
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
For Multi-Parameter Meters see mvx
BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up
Quick Connect. RTDs, Cordsets and Transmitter with M12 Connections
Quick Connect RTDs, Cordsets and Transmitter with M12 Connections 1 Temperature Measurement Experts Since 1960, urns Engineering has been an industry leader in the design and manufacture of temperature
B-Series Temperature Switches
FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment
Toroidal Conductivity Sensor
Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
Micro Motion Model D and DL Coriolis Flow and Density Meters
Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,
AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
The Unique Accelabar Flow Meter
The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.
Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.
Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MR Transmitter with Analog Output Data Sheet SENSORS Document Part Number 550677 Revision J Features 4 to 20
CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips
January 2014 Description The universal CPA PC-Programmable Alarms provide on/off control, warn of unwanted process conditions, and provide emergency shutdown. Very economical, they accept a direct signal
Microcor Wireless Transmitter (MWT)
Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments
Threaded Resistance Thermometers Model TR10-D, Miniature Design
Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-D, Miniature Design WIKA Data Sheet TE 60.04 Applications Machine building, plant and tank construction Power transmission
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
Givare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
Electronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer
PT-400 Heavy Duty, Amplified Output Pressure Transducer C US The PT-400 offers high accuracy and reliability over a wide range of pressures. The small size, integrated electronics, wide operating temperature
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
THERMOCOUPLES GENERAL DESIGN AND SELECTION THERMOCOUPLE STANDARD
THERMOCOUPLES GENERAL Straight Thermocouples Straight thermocouple with metal and ceramic protecting tubes are widely used in a variety of processes between 200 C and 2320 C The maximum operating temperatures
Sanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
Models SFP33 & SFP32 Pressure Transmitters
SFP33 Flow-Through Pressure Transmitter SFP32 Single-Ended Pressure Transmitter DS-PR-SFP-eng April, 2016 Data Sheet Models SFP33 & SFP32 Pressure Transmitters Pressure Brooks Seal Free Pressure Measurement
Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.
GE Measurement & Control Solutions Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically
% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power
.55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard
Pipe Temperature Sensors
Pipe Temperature Sensors Model TE-703 / 704 RoHS Four immersion thermowell installation options brass adapter with 304 SS probe for adjustable insertion, plastic, galvanized steel or NEMA-4/IP-65 steel
Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.
Pump_PT580 Optional PT580-CFG PCM370 Optional DTM96 Buffered Dual Relay Remote Reset Local Display Condition Monitoring System PLC/DCS PT580 Digital Vibration Switch Introduction The PT580 Digital Vibration
Thermal Mass Flow Meter (Series MST)
Overview MaxiFlo TM MST series Thermal Mass Flow Meter is the instrument of choice for reliable and accurate measurement of mass flows for various gases. It measures the mass flow of gas based on constant
OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250
MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic
Technical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.
GE Measurement & Control UNIK 5800/5900 Flameproof/Explosion-Proof Pressure Sensing Platform The 5800 and 5900 are compact and rugged versions of the high performance UNIK 5000 pressure sensing platform
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features
GE Measurement & Control Solutions RTX 1000 Series Versatile Transmitters for a World of Pressure GE Measurement & Control Solutions is renowned for the design and manufacture of compact and rugged high
P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification
P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.
Temperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
Compact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.
and Transmitter All-in-one package for open channel flow measurement. 3.1 NEW Class 1, Division 1 Approved Sensor As our products are continuously improved, we reserve the right to make any change in the
Cerampak is weldable, flexible - can be bent on a radius 2 times its diameter - and moisture free when fabricated.
MGO Thermocouples Thermo Sensors MGO thermocouple insulation materials feature Cerampak. These MGO thermocouples are recommended where the thermocouple is immersed in liquids, high moisture, corrosive
Meter Relays. 077 Series Analogue Meter Relays. Features. Applications
077 Series Analogue Features Monitors and controls any variable which can be converted to an A.C. or D.C. signal. Rugged, shock and vibration resistant design Indicator, relays and power unit in one housing
Rosemount 214C Temperature Sensors
Product Data Sheet November 2015 00813-0500-2654, Rev AA Rosemount 214C Temperature Sensors Primary product benefits igh accuracy resistance temperature detectors (RTD) offered in single and dual element
Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020
Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and vibration resistant
Wahl C50 Calibrator FEATURES
NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,
APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement
For Gauge And Absolute Pressure Measurement Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate
A99B Series Temperature Sensors
FANs 125, 121, 930, 930.5 Product/Technical Bulletin A99 Issue Date 0615 A99B Series Temperature s The A99B Series Temperature s are passive PTC (Positive Temperature Coefficient) sensors. The A99B sensors
Commercial / HVAC / Plumbing. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories
Commercial / HVAC / Plumbing Specification Guide For Pressure & Temperature Instruments & Related Accessories Prepared for Consultant, Design & Specification Engineers Gauges Contractor Gauge (PCT, PCT-LF)
PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features
Features Applications The PMP 4000 Series provides a complete range of high level voltage output pressure transducers offering advanced levels of measurement accuracy, stability and flexibility from a
550658 D. PARAMETER SPECIFICATION Measured Variable: Displacement
T E M P O S O N I C S L S E R I E S LH 550658 D P r o d u c t S p e c i f i c a t i o n s Temposonics L Series position sensors are available with analog outputs (voltage or current) or digital outputs
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
HYDRAULIC AND LUBE OIL HEATERS HYDRAULIC AND LUBE OIL HEATERS. HL Series. Warren Electric Corporation
HYDRAULIC AND LUBE OIL HEATERS HYDRAULIC AND LUBE OIL HEATERS HL Series Warren Electric Corporation Welcome to Warren Electric Quality and Design Excellence has over 35 years of experience in the design
Mini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370
Pump_TM016 Pump Local Display TM0200 TM0200 4-20mA PLC/DCS Case 1 Pump Relay Output Module 4-20mA Optional PT371 Modbus PT373 Case 2 PCM370 TM016 Velocity/ Acceleration Vibration Transmitter Introduction
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
Scraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)
SureGrip TM 80PK-24 Air Temperature Probe Instruction Sheet XWWarning To avoid electrical shock, do not use this probe when voltages exceeding 24 V ac rms or 60 V dc are present. The probe tip is electronically
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief
Rosemount 644 Temperature Transmitter
Product Data Sheet July 2016 00813-0100-4728, Rev UA Rosemount 644 Temperature Transmitter The most versatile temperature transmitter Reduce complexity and simplify the day to day operations of your diverse
Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems
APPLICATION AID SAA20 Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems Duct Air page 4 Thermal-Ribbon pages 6-7 Room Air Compact Room Air page
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:
PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller
BLZPTS-1 NOVEMBER 19, 2013 TS350 TS752 BLPS PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller DESCRIPTION The BLPS, TS350
Analytical Instruments Smart Analyzer 90 Type SMA
Data Sheet Analytical Instruments Smart Analyzer 90 Type SMA Oxygen Only or Optional Oxygen and Combustibles Rugged Industrial Design Easy Installation and Start-up Highly Accurate Sensors Simplified In-house
Screw Plug Immersion Heaters
Immersion Heaters Overview Immersion Heaters consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. Immersion Heaters
Electromagnetic Flow Meter
Electromagnetic Flow Meter Description The EL 2200 series of electromagnetic sensors represent the state of the art for the accurate measurement for water cycle and process applications. Flow meters are
Submersion/Insertion Toroidal Sensor
Instruction Sheet PN 51A-228/rev.P December 2010 Model 228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS
Thermocouples & Thermoresistances
hermocouples & hermoresistances hermocouples emperature probes are basically two wires with particular thermoelectric features, electrically insulated from each other and from the external protection body.
Self-operated Temperature Regulators Temperature Regulator Type 1u
Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50
Duct Temperature Sensors
Duct s Model TE-701 / 702 RoHS More than 16 types of interchangeable NTC thermistors, precision platinum, nickel or balco RTDs are available for universal compatibility. Five installation options probe
Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS
Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and
MGO Insulated Thermocouples Index
MGO Insulated Thermocouples Index PAGE General Information... 2-3 Part Numbering Examples..... 4 Thermocouple Elements (MA)... 5 Leadwire Style Thermocouples (MB)... 6-7 Leadwire Style Thermocouples (MD,
2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
Thermatel Model TA1 Mass Flow Transmitter
Thermatel Model TA1 Mass Flow Transmitter D E S C R I P T I O N Thermatel Thermal Mass Flow Transmitter, Model TA1, provides a high level of performance in mass flow measurement of air and gases. Powerful
Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MG Transmitter with Digital Output.
Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MG Transmitter with Digital Output SENSORS Document Part Number 550784 Revision J Data Sheet FEATURES Modbus
REGULATORS 175/153 Series
175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed
Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics
THORTO Leading Pure Water nalytics Economical Paddlewheel Hi-Purity PF Ultrasonic Vortex Insertion-type Vortex Convenient, Reliable and Economical Flow Measurement Paddlewheel Reliable and Economical Inline
Rosemount 752 FOUNDATION fieldbus Remote Indicator
Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional
Test equipment for temperature and its reduction
Data sheet 90.2721 Page 1/6 Test equipment for temperature and its reduction Pt100 precision RTD temperature probe Calibrated temperature measuring chain with precision display device Calibrations as service
VALVES FOR REFRIGERATING SYSTEMS
VALVES FOR REFRIGERATING SYSTEMS FROM QUALITY OUR NATURAL DEVELOPMENT Achieved the goal of fi fty years working in the industry of Refrigeration and Air Conditioning, Castel Quality Range of Products is
1/2 NPTM. 29.21 mm 1.15. Nose cone fitting Ideal for clean liquids
PT-500 Submersible Liquid Level Transmitter 1.0 Hex 25.4 mm 7.0 177.8 mm Re-Usable cage fitting Ideal for dirty liquids 5.63 143 mm 5.33 136 mm 1/2 NPTM 3.5 88.9 mm 1.15 29.21 mm Nose cone fitting Ideal
key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100
Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When
Proximity Transmitters and Seismic Vibration Transmitters
Proximity Transmitters and Seismic Vibration Transmitters TR1101 Seismic Vibration Transmitter The TR1101 is a cost-effective solution for monitoring case vibration on balance of plant machines. The TR1101
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases Reliable and accurate: Thermal Mass Flow Meters and Controllers Reliable technology and industry standard interfaces
STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features
GE Measurement & Control STX2100 Differential Pressure (Flow) Transmitter Models FKC...5 The STX2100 differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge
Turbine Flowmeters for Gas Applications
Turbine Flowmeters for Gas Applications Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because
Technical data sheet TDS0070
Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
CARTRIDGE HEATERS TECNOLOGIC UK. Tel: 01252 377600 l www.t-uk.co.uk Complete temperature control solutions
CARTRIDGE HEATERS TECNOLOGIC UK Tel: 01252 377600 l www.t-uk.co.uk Complete temperature control solutions INDEX CONSTRUCTION 3 STANDARD SPECIFICATIONS 3 WATT DENSITY 4 SHEATH OPTIONS 4 LEAD WIRE OPTIONS
FLOW SYSTEM flow measurement system in open channels and non-pressurized pipes
FLOW SYSTEM flow measurement system in open channels and non-pressurized pipes The flow measurement in open channels is based on the measurement of the increase in height due to the insertion of a suitable
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Portable digital microprocessor thermometers with interchangeable probes
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: [email protected] Internet: www.jumo.net
Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS
EPP - 1 DECRIPTION The odel 575 is used in general water/wastewater applications. The transmitter is offered in a standard non-clogging snub nose end, flush diaphragm or protected flush diaphragm with
3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
Trouble shooting guide
guide DPR/PSR Leak Insuffi ciently tightened, shallow bite Tighten the nut according to correct number of turns, direct assembly only for maintanance/repair, use of recommended pre-assembly machines Mark